remote gsm based mobile starter for motor / pump
DESCRIPTION
M4 GSM IS WIRELESS UNIT USING WHICH YOU CAN START STOP MOTOR OR ANY DEVICE USING MOBILE PHONE AND OUR TALKS WITH YOU ONLINE IN LOCAL LANGUAGE ...AND MUCH MORE VISIT WWW.KHYATEE.INTRANSCRIPT
Started in 1995 as SSI unit in pune.• 15000 sq. feet manufacturing set up• Certified ISO:9001:2008 including R & D• Maximum Backward integration with more than 130 dies
and moulds• Own unit to manufacture transformers• In house PLC based wave soldering machine• Own R & D team for software and hardware• Sold more than 9 lac quantity in last 15 years
About KHYATEE
KHYATEE GSMWIRELESS DATALOGGER
KHYATEE PRODUCT RANGE• Microcontroller based digital pump control panels Digital DOL and Star Delta Starters• Microcontroller based Mobile Starters and Panels • GSM based Starters and Panels and data loggers• RO / Water treatment plants panels and automation.• Conductivity / Flow measurement systems.• Automatic power factor panels • Digital hydro pneumatic systems• Bio medical infusion pumps and monitoring systems• Digital timers, level controllers, ELCB etc• Custom build automation panels etc.
KHYATEE GSMWIRELESS DATALOGGER
Khyatee range of remote data loggers for wire less industrial and process automation.
This wire less remote data loggers can be used for real time on line data acquisition, monitoring and control of remotely installed electrically systems.
KHYATEE GSMWIRELESS DATALOGGER
The microprocessor based wireless remote data logger is extremely flexible, easy to set, use and reliable system that is fully pre programmed, you only need to connect it with a pump/motor to be controlled from remote location.
KHYATEE GSMWIRELESS DATALOGGER
HOW IT WORKS Khyatee GSM data logger uses activated SIM card
from any GSM service provider which communicates with server or any mobile phone by sms or talks on phone in required language
For example system is installed and connected to motor than it continuously monitors every activity of pump or motor at site and sends all data to the server or any mobile phone by SMS on real time basis.
KHYATEE GSMWIRELESS DATALOGGER
HOW CAN A PERSON USE THE SYSTEM? It is very easy just dialed SIM card number
connected at site unit will ask 4 digit password after entering correct password you can do following things:
Press 0 to get power and motor information on site Press 8 for online help. Press 7 to start motor. Press 9 to stop motor. Press 5 to change pass word. Press * to reset the fault. Press # to cut off the phone.
KHYATEE GSMWIRELESS DATALOGGER
• UNIT TALKS WITH YOU LIKE… Password is right or wrong Motor is ON or OFF ? Power is present Your motor has started Motor has become OFF due SPP, overload, DryRun, WLC etc. Online help for How to use it ? Switch is in Auto/Manual/Bypass Your password is changed etc
KHYATEE GSMWIRELESS DATALOGGER
• Saves
Time, Money, Power, Labour, Petrol, Water, Frustration.
• You Get
Peace, Satisfaction, Health, More Crop, More Money…
KHYATEE GSMWIRELESS DATALOGGER
PROTECTIONS Phase failure / loss from supply and motor side Phase reversal / wrong phase sequence from supply
side. Phase to phase current unbalance Electronic overload Remote sensing dry run / No load current Extreme high current (EHC) High and low voltage Fully automatic water level controller
KHYATEE GSMWIRELESS DATALOGGER
Settable parameters Overload from 20 to 50 % of set current DryRun from 75 to 95 % in increment of 1 %/Amp Current unbalance from 20 to 70% Power on timer 3 to 300 seconds Star Delta Timer with indication (3 to 30 sec.) RTC based on time and off time DryRun bypass facility with digital display.
KHYATEE GSMWIRELESS DATALOGGER
TIMERS Digital display for countdown timer Site settable auto start timer (3-300 secs) for power
failure and SPP faults from supply side. Site settable star delta timer ( 3-30 secs.) Site settable dry run auto start timer(10-720 min) Time delay to filter power on spikes and surges.
KHYATEE GSMWIRELESS DATALOGGER
• FEATURES 4 Digit Password protected operation Talks 40 verbal information in required language Works on wide voltage supply (100 to 500 V) Auto Start Timer with Indication (1 to 5 min) Site selectable Auto / Manual operation switch. Facility to check network communication between
GSM sim and dialer phone.
KHYATEE GSMWIRELESS DATALOGGER
• FEATURES Suitable for DOL, Star-Delta Starters up to 500 HP No call charges when power is absent. Auto call disconnect facility to save call charges Motor ON and OFF switch on unit Switch for Easy bypass and network checking Color coded Wires from unit for easy wiring
KHYATEE GSMWIRELESS DATALOGGER
MONITORING
Calibrated Digital Voltmeter from 90-500 Volt Calibrated Digital Ammeter 0.5-40 or100 Amps Scrolling Ammeter for R, Y, B, Phases Count down timer on display Inbuilt memory to show last setting value On site AUTO FAULT DETECT (AFT) for AC voltage, LEDS,
Display, Relay, etc.
KHYATEE GSMWIRELESS DATALOGGER
INDICATIONS AND DISPLAYS Auto scrolling display for updated pump current and
line voltage Indication for individual R Y B phase loss. Ultra bright indicators for all faults Early fault warnings by blinking LED. Value of tripping current / voltage.
KHYATEE GSMWIRELESS DATALOGGER
INDICATIONS AND DISPLAYS Healthy condition SPP / CUB / RP Overload Dry run Mobile / Short circuit R phase Y phase B phase
KHYATEE GSMWIRELESS DATALOGGER
SMS FACILITY Khyatee GSM data logger has very simple to use
SMS facilities even for common man like farmers.
You can set 8 SMS recipients no in the system just
by sending SMS to the unit like*A5678*9422548210#
You delete any recipients by sending SMS like *D5678*9422548210#
KHYATEE GSMWIRELESS DATALOGGER
SMS FACILITY You can get status/list of SMS recipients *S5678# If you want all help detail by SMS than send *H5678#
to the unit. You can reset the fault by SMS *R5678# You can set RTC based ON time OFF time by
sending SMS.
KHYATEE GSMWIRELESS DATALOGGER
WHAT DATA/REPORTS WILL YOU GET AT A CENTRAL SERVER?
All report can be seen on internet. Motor on time report. Motor fault report. Power failure report. Power resumes report. Motor current and voltage.
KHYATEE GSMWIRELESS DATALOGGER
What data/reports will you get at a central server?
Motor disconnection report from output terminal or at motor end (motor theft protection).
Panel door opening report. Pre defined motor starting report three or four times
a day. Motor location report. SIM card tracking report.
KHYATEE GSMWIRELESS DATALOGGER
APPLICATIONS
Remote sensing and monitoring of electrical fault in a pump or motor
Remote sensing and monitoring of electrical fault in a high tension power line.
Remote water management for flow measurement etc. Remote monitoring of water level at railway bridges, dam
etc. Temperature, moisture and water management in drip
system. Like can be used for HT/LT electrical motors, power line,
generators or any other electrical machines and systems
KHYATEE GSMWIRELESS DATALOGGER
THANK YOU…
KHYATEE GSMWIRELESS DATALOGGER
KHYATEE GSMWIRELESS DATALOGGER
KHYATEE GSMWIRELESS DATALOGGER
KHYATEE GSMWIRELESS DATALOGGER
KHYATEE GSMWIRELESS DATALOGGER