report on ccauv.v k3 low frequency vibration comparison · 2017. 9. 28. · 28 conclusion the first...

29
Report on CCAUV.V-K3 low frequency vibration comparison 2017-09-20 SUN Qiao National Insititute of Metrology, China CCAUV/17-10

Upload: others

Post on 22-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

Report on CCAUV.V-K3

low frequency vibration comparison

2017-09-20

SUN Qiao

National Insititute of Metrology, China

CCAUV/17-10

Page 2: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

2

Contents

Metrological background of low frequency vibration

RMO low frequency vibration comparisons

CCAUV low frequency vibration comparison

Conclusion

Page 3: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

3

Metrological Background

Source: APMP TCAUV DEC Workshop 2014

by Mr. Suwandi. A, KIM-LIPI

Page 4: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

4

Metrological Background

Source: APMP TCAUV DEC Workshop 2014

by Mr. Shinji SATO, Railway Technical Research Institute, Japan

Page 5: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

5

Metrological Background

Source: APMP TCAUV DEC Workshop 2014

On-site visit, Thailand

Page 6: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

6

Metrological Background

Source: APMP TCAUV DEC Workshop 2014

by Mr. Suwandi. A, KIM-LIPI

Page 7: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

7

Contents

Metrological background of low frequency vibration

RMO low frequency vibration comparisons

CCAUV low frequency vibration comparison

Conclusion

Page 8: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

8

RMO comparisons

Supplementary comparison in 3 RMOs (18 Participants)

AFRIMETS.AUV.V-S2

EURAMET.AUV.V-S1

2 participants (0.4 to 50) Hz

APMP.AUV.V-S1 7 participants (0.5 to 20) Hz

10 participants (1 to 80) Hz

2010 to 2011

2011 to 2012

2012 to 2013

Page 9: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

9

RMO comparisons

Page 10: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

10

RMO comparisons

Monitoring measurements performed 2010-2011

Page 11: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

11

RMO comparisons

Comparison transfer standards (Gw10kg)

Comparison measurements carried out 2011-2012

Page 12: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

12

RMO comparisons

Planned

in 2011 KRISS

July

NMIJ June

NIMT

Aug

CMS

Sept

NMIA

Oct NMISA

Nov

1

2

3

Page 13: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

13

RMO comparisons

Source: Report of NMIJ to the 11th APMP TCAUV 2011

by Dr. T. KIKUCHI

Page 14: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

14

RMO comparisons

KRISS

Mar

NMIJ

Dec

NIMT

Aug

CMS

Sept

NMIA

Oct NMISA

Nov

1

2

rearranged

Page 15: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

15

RMO comparisons

NIM Horizontal Vertical

Horizontal

Vertical

Self-developed systems

NMIJ

(0.1 - 20) Hz (0.1 - 20) Hz

(0.5 - 2) Hz

(>2 - 20) Hz

Page 16: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

16

RMO comparisons

CMS

NIMT

Horizontal

Vertical

Commercial systems

KRISS Horizontal

NMISA Horizontal (0.5 - 20) Hz

(0.5 - 20) Hz (0.5 - 20) Hz

(0.5 - 20) Hz

Page 17: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

17

RMO comparisons

Installation direction

Note: Horizontal motion is the main

cause of building destruction.

Page 18: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

18

RMO comparisons

Installation direction

Note: Sensors are tri-axis,

but horizontal X and Y

axis are very important

directions.

Page 19: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

19

Contents

Metrological background of low frequency vibration

RMO low frequency vibration comparisons

CCAUV low frequency vibration comparison

Conclusion

Page 20: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

20

CCAUV comparison

No. NMIs low limit Direction

1 NMISA 0.4 Horizontal

2 KRISS 0.1 Horizontal

3 NIM 0.1 Horizontal

4 NMIJ 0.1 Horizontal

5 BKSV-DPLA 0.1 Horizontal

6 NMIA 0.1 Horizontal

7 LNE 0.4 Horizontal

8 METAS 0.4 Horizontal

9 PTB 0.4 Horizontal

10 INMETRO 0.4 Horizontal

11 CENAM 0.1 Horizontal

12 A*STAR 0.1 Horizontal

13 VNIIM 0.1 Horizontal

14 GUM 0.4 Horizontal

Participants List

Page 21: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

21

CCAUV comparison

Page 23: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

23

CCAUV comparison

Page 24: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

24

CCAUV comparison

136.1

136.2

136.3

136.4

136.5

136.6

136.7

136.8

136.9

137.0

03/2014 04/2014 05/2014 06/2014 07/2014 08/2014 01/2015 03/2016

mag

nit

ud

e in

mV

/(m

/s²)

1.6 Hz

-0.3

-0.2

-0.1

0.0

0.1

0.2

03/2014 04/2014 05/2014 06/2014 07/2014 08/2014 01/2015 03/2016

ph

ase i

n °

1.6 Hz

Page 25: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

25

CCAUV comparison

Comparison results

Page 26: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

26

CCAUV comparison

Comparison results

Page 27: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

27

Contents

Metrological background of low frequency vibration

RMO low frequency vibration comparisons

CCAUV low frequency vibration comparison

Conclusion

Page 28: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

28

Conclusion

The first low-frequency CIPM key comparison CCAUV.V-K3 in

vibration revealed the current calibration capabilities of the 14

participants of 5 RMOs. 13 participating laboratories provided their

calibration results, which were mostly consistent within their

declared expanded uncertainties.

For magnitude results, only 2 participants failed to contribute to

the KCRV values calculated for 5 frequencies out of a total of 27

comparison frequencies.

For phase shift, 3 participants could not contribute to the

calculation of the KCRV values in a total of 16 frequencies. Better

understanding of their calibration devices and more reasonable

evaluation of their calibration uncertainties will provide more

accurate and reliable measurement results in the future.

Page 29: Report on CCAUV.V K3 low frequency vibration comparison · 2017. 9. 28. · 28 Conclusion The first low-frequency CIPM key comparison CCAUV.V-K3 in vibration revealed the current

Thank you for your attention!

Tel.: +86 10 64524623 E-mail:[email protected]