Reverse Osmosis (RO) Drinking Water System Model RO450/RO450M Installation & Maintenance Manual (Please save for future reference) INTRODUCTION The Rainfresh RO system uses hyper-filtration technology (commonly called Reverse Osmosis or RO). The four-stage filtration system reduces molecular and ionic contaminants by up to 99% - Barium, Cadmium, Chromium, Copper, Fluoride, Lead, Mercury, Nitrates, Sodium, Total Dissolved Solids, Chlorine,Taste and Odour. It also traps protozoan cysts (Cryptosporidium & Giardia) greater than 99.95% and filters sediment, silt and rust. Water produced by the Rainfresh RO system can be used for drinking, cooking, juices, beverages, watering plants, steam irons, humidifiers, aquariums etc. OPERATING SPECIFICATIONS (1) Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. For effective disinfection we recommend Rainfresh Whole-house UV disinfection systems. Warning: Individuals requiring water of specific microbiological purity should follow the advice of their doctor or local health unit. (2) If water pressure can exceed 100psi, a pressure regulator and water hammer arrestor must be installed before the filter. Recommended regulator setting is 60-75 psi. (3) System will operate with hard water, but membrane life may be shortened. The unit should be operated with water that meets the following minimum criteria. Source water exceeding chemical parameters (listed below) requires pre-treatment. Raw Water Supply Chemical Parameters Water Supply = Bacteriologically Safe (1) Max Hardness < 170mg/L (<10 gpg) (3) Feed Water Pressure = 45 (min) to 100 psi (max) (2) Iron (Fe) < 0.1 ppm (mg/L) 3.16 Kg/cm 2 to 7.4 Kg/cm 2 Manganese (Mn) < 0.05 ppm (mg/L) Feed Water Temp. = 4ºC - 38ºC (40ºF - 100ºF) Hydrogen Sulfide = 0.00 ppm (mg/L) Feed water pH = 3.0 to 11.0 Feed Water TDS (max) = 1500 ppm (1500 mg/L) Feed Water Turbidity = 1.0 NTU (max)(NTU) TDS > 1000 ppm may Production Rate = 17.7 US GPD (66.9 Litres per day) require booster pump. Call Rainfresh if needed. Average efficiency rating - 9.1% - Efficiency rating means the percentage of the influent water to the system that is available to the user as RO treated water under operating conditions that approximate typical daily usage. Average recovery rating - 18% - Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as RO treated when the system is operated without a storage tank or when the storage tank is bypassed. This system may be used for treatment of influent concentrations of no more than 27 mg/L nitrate measured as N and is certified for nitrate reduction only for water supplies with a pressure of 40 psig (280 kPa) or greater. For optimum performance of the system, filters should be replaced as per following: Pre-filter 1 - Model HP1 : Replace every six months Pre-filter 2 - Model CF2 : Replace every six months Post-filter - Model IM200 : Replace every six months RO Membrane - Model ROM50 : Replace every 1-4 years Note : Cartridge and membrane life is directly dependent on your water conditions and the volume of water filtered. Excessive sediment and other contaminants may require more frequent replacement. Note: This reverse osmosis system contains a replaceable membrane critical to the effective reduction of total dissolved solids . Raw and product water should be tested every six months by a water analysis lab to verify that the system is performing properly. Only replacement membrane model RO50M should be used to assure the same efficiency and contaminant reduction performance. Nitrate Reduction Performance A Nitrate test kit is included witht this system to verify Nitrate-reduction performance. The test should be performed at installation (after 3 tank flushes) and at least every six months thereafter. Instructions: The test kit included has two test strips. You need only one test strip per test. Follow instructions on the test package. Compare the colour to the test strip with the nitrate nitrogen colour shades on the test package. The colour should match with 10 PPM or less. Additional testing and verification for reduction of Barium, Cadmium, Chromium, Copper, Cyst (e.g. Cryptosporidium & Giardia), Fluoride, Lead, Mercury, Nitrates and Chlorine performed by independant laboratory. Claims not performance certified by CSA International Tested and Certified by CSA International to CSA B483.1, and to NSF/ANSI standard 58 for the reduction of Total Dissolved Solids (TDS) & Sodium. 1. Drinking Water Eau potable

Upload: others

Post on 27-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Reverse Osmosis (RO) Drinking Water System Model RO450/RO450M

Installation & Maintenance Manual (Please save for future reference)

INTRODUCTIONThe Rainfresh RO system uses hyper-filtration technology (commonly called Reverse Osmosis or RO). The four-stage filtration system reduces molecular and ionic contaminants by up to 99% - Barium, Cadmium, Chromium, Copper, Fluoride, Lead, Mercury, Nitrates, Sodium, Total Dissolved Solids, Chlorine,Taste and Odour. It also traps protozoan cysts (Cryptosporidium & Giardia) greater than 99.95% and filters sediment, silt and rust. Water produced by the Rainfresh RO system can be used for drinking, cooking, juices, beverages, watering plants, steam irons, humidifiers, aquariums etc.

OPERATING SPECIFICATIONS (1) Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. For effective disinfection we recommend Rainfresh Whole-house UV disinfection systems. Warning: Individuals requiring water of specific microbiological purity should follow the advice of their doctor or local health unit. (2) If water pressure can exceed 100psi, a pressure regulator and water hammer arrestor must be installed before the filter. Recommended regulator setting is 60-75 psi. (3) System will operate with hard water, but membrane life may be shortened.The unit should be operated with water that meets the following minimum criteria. Source water exceeding chemical parameters (listed below) requires pre-treatment.

Raw Water Supply Chemical Parameters Water Supply = Bacteriologically Safe (1) Max Hardness < 170mg/L (<10 gpg) (3) Feed Water Pressure = 45 (min) to 100 psi (max) (2) Iron (Fe) < 0.1 ppm (mg/L) 3.16 Kg/cm2 to 7.4 Kg/cm2 Manganese (Mn) < 0.05 ppm (mg/L) Feed Water Temp. = 4ºC - 38ºC (40ºF - 100ºF) Hydrogen Sulfide = 0.00 ppm (mg/L) Feed water pH = 3.0 to 11.0 Feed Water TDS (max) = 1500 ppm (1500 mg/L) Feed Water Turbidity = 1.0 NTU (max)(NTU) TDS > 1000 ppm may Production Rate = 17.7 US GPD (66.9 Litres per day) require booster pump. Call Rainfresh if needed.

Average efficiency rating - 9.1% - Efficiency rating means the percentage of the influent water to the system that is available to the user as RO treated water under operating conditions that approximate typical daily usage.Average recovery rating - 18% - Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as RO treated when the system is operated without a storage tank or when the storage tank is bypassed. This system may be used for treatment of influent concentrations of no more than 27 mg/L nitrate measured as N and is certified for nitrate reduction only for water supplies with a pressure of 40 psig (280 kPa) or greater.

For optimum performance of the system, filters should be replaced as per following: Pre-filter 1 - Model HP1 : Replace every six months Pre-filter 2 - Model CF2 : Replace every six months Post-filter - Model IM200 : Replace every six months RO Membrane - Model ROM50 : Replace every 1-4 years Note : Cartridge and membrane life is directly dependent on your water conditions and the volume of water filtered. Excessive sediment and other contaminants may require more frequent replacement.Note: This reverse osmosis system contains a replaceable membrane critical to the effective reduction of total dissolved solids . Raw and product water should be tested every six months by a water analysis lab to verify that the system is performing properly. Only replacement membrane model RO50M should be used to assure the same efficiency and contaminant reduction performance.Nitrate Reduction PerformanceA Nitrate test kit is included witht this system to verify Nitrate-reduction performance. The test should be performed at installation (after 3 tank flushes) and at least every six months thereafter.Instructions: The test kit included has two test strips. You need only one test strip per test. Follow instructions on the test package. Compare the colour to the test strip with the nitrate nitrogen colour shades on the test package. The colour should match with 10 PPM or less.

Additional testing and verification for reduction of Barium, Cadmium, Chromium, Copper, Cyst (e.g. Cryptosporidium & Giardia), Fluoride, Lead, Mercury, Nitrates and Chlorine performed by independant laboratory. Claims not performance certified by CSA International

Tested and Certified by CSA International to CSA B483.1, and to NSF/ANSI standard 58 for the reduction of Total Dissolved Solids (TDS) & Sodium.

1.

Drinking WaterEau potable

INSTALLATION CAUTIONS1 The RO system is designed for point-of-use (POU) under-sink installation for single-faucet dispensing only. 2. Installation of this unit may involve some water spillage. Keep an ample supply of paper towels or an absorbent cloth handy.3. This system is intended for use with cold water only. Hot water can damage the membrane.4. Do not attempt to operate the system without the pre-filters. This can severely damage the membrane.5. Ensure that there are no kinks in any of the tubing that can restrict or stop the water flow and cause damage to the system.6. Protect filter from direct sunlight. Not intended for outdoor use.7. Protect your unit from freezing temperature.8. Installation shall comply with applicable plumbing codes and regulations. This unit comes complete with all necessary fittings to install the unit below the counter to copper or CPVC rigid plastic pipe. The water supply saddle valve is included for use in areas where codes permit.Wherenotpermitted,theinstallermustprovideapprovedfittingstotapthecoldwaterpipeforafeedwatersourcetothefilter system (must adapt to ¼” OD tubing)

2.

HOW YOUR RO SYSTEM WORKSWater first flows through a 1 micron sediment filter (HP1) followed by an activated carbon filter (CF2) that reduces chlorine, taste and odour. The third and most important stage of the system is the Reverse Osmosis Membrane that rejects most of the dissolved contaminants listed above, while the filtered water (called Permeate) passes through a final stage of taste and odour polishing, before flowing out of the faucet. As the RO membrane rejects contaminants at a molecular level, some of the water, along with the contaminants, flows to the drain. To achieve such fine filtration, the water production rate is slower than conventional under-sink filtration systems. Therefore, a pressurized storage tank is used to provide RO water through the faucet at normal flow and pressure. The storage tank holds a maximum of 2.2 US gallons (approx. 12 liters) of filtered water. When the storage tank is full, an automatic valve shuts off the water supply to the RO membrane. As water is used from the faucet and the pressure in the tank drops to about 65% of full pressure, the automatic shut-off valve opens and allows feed water into the RO membrane until the storage tank is full again. Model RO450M also features an electronic monitor that tracks the 6-month filter life and blinks when it is time for the pre & post filters to be changed.

Blueee

RR

FAU

CET

Stage 1Stage 2

Stage 3

Stage 4

Red

Flow Restrictor2611-1

Black

WhiteTankTube

Grey

2609Fig. 1

INSTALLATIONNecessary Installation ToolsVariable speed drill, drill/spade bits - 3/8", 7/8", utility knife, 2 adjustable wrenches, flashlight, flat-head & phillips screwdrivers.

Fittings and Tubing (See Fig. 2)Accu-Link™ quick-connect fittings are used throughout the system with the exception of the self-piercing saddle valve and faucet connections. To ensure an optimal seal, tubing should be cut straight. An angled cut or distortion of the tubing will not provide an efficient seal and may cause leaks. To install a 1/4” tube (blue, white, grey, red), mark it 5/8” from the end then push it firmly 5/8” through the collet, past the o-ring until it seats on the tube stop. Note: For 3/8” black tube, mark and push tube in 3/4”. To remove a tube, push in the collet with two fingers on each side of the tube and pull out the tube. All extra tubing (grey, red, black, blue only) should be cut so that only optimum length of tubing remains. Loops or extra lengths of tubing are not recommended. Cut tubing to size wherever necessary.

Starting Your InstallationSystem and installation shall comply with state and local regulations.This unit comes complete with filter, cartridges, membrane, air-gap faucet, housing assembly, pressurized storage tank, do-it-yourself instructions and all necessary fittings to install the unit below the counter to copper or CPVC pipe. A typical installation is shown in Fig. 1 on page 2. Installation of the unit includes the following steps: 1. Air-gap faucet connection 4. Feed water connection.2. Drain connection 5. Storage tank connection 3. Mounting the main unit.

Air-gap Faucet Installation (See Fig. 3)The faucet (2600-0) may be installed on the counter-top or the sink, as desired. For counter-top installation, position faucet on counter-top beside sink where it will not be obstructed from above or below.

For Porcelain/Enamel SinksA spring-loaded Relton style drill set is strongly recommended to prevent chipping. Use a carbide-tipped drill bit to drill a 1/8” pilot hole completely through the porcelain. Use lubricating oil or liquid soap to keep the drill bit cool while drilling. Next, using a spring-loaded porcelain saw, cut through the porcelain surface only. Finally, use a 7/8” finishing hole saw to cut through any remaining metal. Avoid high motor RPM during the initial cutting of the porcelain as this can cause chipping.

For Stainless Steel SinksMake a small indent to mark the desired drilling location using a centre punch. Drill a pilot hole with a 1/8" metal drill bit. Enlarge the hole using a 7/8" metal drill bit. Then de-burr the hole and file smooth.

For Laminate Countertops1. Mark the location and drill a 7/8” hole.2. Insert the faucet tubing (1/4” grey and 3/8” black) first through the countertop hole followed by the faucet with drain hole in faucet body facing sink.3. Install slotted washer (2650-4), spacer (2650-5), bottom washer (2650-6) and lock-nut (2650-7). Tighten lock-nut while someone holds the faucet so it does not turn. 4. Slide compression nut (1030-15), sleeve (1008-3) on to one end of blue tube (2622) and push insert (1603) into end of tube as shown in Fig 6. Push tube into threaded end of faucet and hold firmly in place and tighten nut securely with a wrench, again while someone holds faucet so it does not turn.

3.

Fig. 2

Collet

R

2650-3

2650-2

2650-13

2650-10Air gapfaucet complete

2650-0

2650-4

Counter Top

2650-5

2650-62650-71603 1008-3 1030-15 Compression nut

Sleeve Tube insert

Lock nut Bottom washer

Spacer

Slotted washer

Escutcheon washer

Stem Assembly

Lever

Fig 3

Drain Connection1. Mark a spot on the vertical drain pipe under sink and drill a 3/8" (9 mm) hole in it, preferably facing direction of faucet. Make sure that while drilling you do not drill right through the other side of the pipe. 2. Peel the protective film off the sponge gasket and apply to inside of drain saddle (2618), using care to align sponge gasket hole with drain saddle hole. 3. Mount the drain saddle on the drain pipe and align the drain saddle hole with the 3/8” drilled hole (use a flashlight to see clearly). Use a drill bit or any narrow straight object to confirm that the two holes are aligned. Tighten the saddle nuts and firmly secure the saddle in place. Do not over-tighten. (see Fig. 4)4. Measure length of 3/8” black drain tube (2624) needed to connect to drain saddle. CAUTION: This is a gravity drain line and should be as short as possible (See Fig. 1). Water may leak from drain hole on the faucet. Cut off any excess tube and connect to drain saddle. Mark tube 3/4” from end and insert firmly 3/4” through collet past O-ring until it seats on tube stop (See Fig. 2).Mounting the main unitLocate best side wall position for mounting unit under-sink near faucet. NOTE: Leave a minimum of 5 inches clearance below sumps to allow for removal of cartridges. The higher and closer to the front you mount the unit, the better it will be for regular maintenance/servicing.1. Unpack unit and pull post-filter (IM200) towards front to expose mounting bracket (2613). Mark mounting bracket screw locations using mounting bracket as a template and set unit aside. 2. Partially screw the two mounting screws (1011-0) into screw locations. NOTE: If wall is too thin to accept screws, use round-head nuts and bolts (not supplied) to mount bracket. Install pre-filters and membrane as per instructions below before mounting unit on the wall.3 Installing Pre-filters: a) Turn each sump (520) 1/8 turn to left and pull away from head (2501) to remove. b) Pull pre-filters (HP1 & CF2) gently away from head, remove shrink-wrap and re-install open end of pre-filters on to head boss. c) To replace sumps, align sump grooves with head lugs and push straight up on to the head. Turn sumps 1/8 turn to right fully to stop (lock position). 4. Installing the RO Membrane (See Fig. 5) To make membrane installation easier, the tube to the membrane housing cap (2601) is not connected when the unit is shipped. a) Unscrew the membrane housing cap and take it off . b) Remove new membrane (ROM50) from bag and apply silicone lubricant (included) on the two "O" rings. Caution: Do not use any other lubricants. c) Slide membrane into housing, O-ring side first. Push membrane completely in until slotted end is flush with housing opening. If you cannot push membrane fully in, pull it out and apply some more lubricant and repeat procedure. d) Replace housing cap taking care that the "O" ring inside it does not come out. Firmly hand-tighten the cap. e) Insert unconnected white tubing into housing inlet fitting (2609). Mark tube 5/8” from end and push firmly 5/8” through collet past O-ring until it seats on the tube stop (See Fig. 2).5. Installing the monitor battery (Model RO450M only) a) Remove plastic cover (2508) on top of the inlet pre-filter housing by prying up gently with finger nails at front and back. b) Unwrap battery (2545) and insert “+” side up into battery slot and replace cover. Press and hold black button until orange LED blinks four times; then release button to set monitor.6. Mount the unit on to the mounting screws and tighten screws.7. Connect grey drain tube (2623) from faucet to drain fitting (2609) (See Fig. 1 inset). Flow restrictor (2611-1) is installed at the end of the grey tube. Insert this end of the grey tube (with 2611-1) into the drain fitting (2609) as shown in fig 1 inset.8. Measure length of 1/4” blue tube (2622) from faucet needed to connect to open left end of post-filter (IM200) without kinks and cut off any excess (See Fig. 1). Mark and insert tube 5/8” as shown in Fig. 2.

Fig. 4

4.

Fig.5

Saddle Valve Installation Installation shall comply with applicable plumbing codes and regulations. This unit comes complete with all necessary fittings to install the unit below the counter to copper or CPVC rigid plastic pipe. The water supply saddle valve is included for use in areas where codes permit.Wherenotpermitted,theinstallermustprovideapprovedfittingstotapthecoldwaterpipeforafeedwatersourcetothefilter system (must adapt to ¼” OD tubing)NOTE: The Saddle Valve (1008-1) can be installed on copper or CPVC rigid plastic pipe of 3/8" to 1" diameter. (Not recommended for flexible plastic pipe). NOTE: If your cold water line is other than described, use fittings (not included), that adapt to 1/4” OD tubing or contact Rainfresh for assistance.IMPORTANT: Orient saddle valve with outlet threads pointing towards INLET fitting (2606) (see fig 1). 1. Back-off handle on saddle valve to retract piercing tip. With rubber gasket in a fixed position clamp entire assembly to pipe using bolts provided. Tighten bolts, keeping brackets parallel until rubber gasket is firmly compressed. Caution: Do not over-tighten. 2. Measure length of 1/4” red plastic tubing (2619) from RO inlet needed to connect to saddle valve without kinks and cut off any excess tube. 3. Slide compression nut (1030-15) and sleeve (1008-3) onto tube, then put tube insert (1603) into tube (see Fig. 6). Push tube into end of saddle clamp fitting and hold firmly in place. Securely tighten compression nut while holding other end of fitting with a wrench.

Storage Tank Connections

1. Place the storage tank on its base under the sink. The tank valve (2617) and white tubing (2620) are pre-connected to the tank. 2. Insert open end of 1/4” white tube (2620) into “Tee” fitting (2612) at right end of post-filter (IM200). Mark and insert tube 5/8” (See Fig. 2).START - UP PROCEDURE1. Turn the feed water saddle valve clockwise until handle is seated. You have now pierced the pipe and closed the valve.2. Open your under-sink cold water valve, or the main water shut-off valve, whichever you had closed and check for leaks. Turn saddle valve handle counter-clockwise all the way to open valve and start water flow. Check all fittings for leaks. 3. Turn storage tank valve one quarter turn left (counter-clockwise) to open. The handle should be in line with the tubing as it enters the connection (See Fig. 7). 4. Your unit is now in operation.NOTE: Do not consume the water prior to three tank flushes. See tank flushing procedure below.NOTE: A mild dripping or gurgling sound should be heard from the drain-hole in the faucet when the RO system is making water. This is normal.Flushing the Tank Allow the storage tank to fill up. This can take from 2-5 hours depending on your feed water pressure. Open the faucet and flush out the tank completely until flow becomes a trickle. Repeat procedure for two more tank flushes. This procedure is required to flush out the sanitizing solution in the RO membrane. The system is now ready for use.

OPERATION AND MAINTENANCEElectronic Monitor Functions (Model RO450M only)The electronic monitor tracks the 6 month period and the orange LED blinks when the limit is reached, advising you to replace the two pre-filters (Model HP1 & CF2) and the post-filter (Model IM200) as soon as possible. The monitor does not track the life of the RO membrane. Set monitor before beginning service and re-set after car-tridge replacement as follows:

Setting/Re-setting the monitor (See Fig. 8) Press and hold black button until orange LED blinks 4 times, then release button. This activates monitor function that tracks time used. When 6 months expire, the orange light will blink every 5 seconds advising you to replace the cartridges.

Battery Life - Approximately 4 years. To test battery - Press black button for two seconds or less. If Orange LED lights, then power is on and monitor is working. Replace battery when LED does not light. To replace battery, remove plastic cover by prying up gently with finger nails at front and back. Pull used battery out of slot and push new battery (2545) into slot “+” side up and replace cover.

Fig. 8

5.

Fig. 6

Fig. 7

Caution: DO NOT TAMPER WITH THE AIR VALVE ON THE STORAGE TANK. IT HAS BEEN FACTORY PRE-SET AT 5-6 PSI (EMPTY PRESSURE)

Filter and Membrane ReplacementCaution: Routine maintenance of this unit may involve some water spillage. Keep an ample supply of paper towels or absorbent cloth handy.

Pre-filter Replacement Procedure (HP1 & CF2)1. Shut off cold water supply to the unit, shut off tank valve and turn on faucet to de-pressurize unit. 2. Turn sumps 1/8 turn to left, lower to remove, discard old filters and insert new filters. Replace sumps and turn 1/8 turn to right fully to stop (Lock Position). 3. Open supply valve, check for leaks, then open tank valve.

Post-Filter Replacement (IM200) 1. Shut off cold water supply to the unit, shut off tank valve and turn on faucet to de-pressurize unit. 2. At each end of the post-filter, push the collet in with two fingers and pull the tubing out (See Fig 2). 3. Lift post filter out of double clips (2605). Push new post filter on to clips (make sure arrow on filter points in correct direction (right to left). 4. Push tubes firmly back into collets 5/8” to tube stop at both ends.(See Fig. 2)5. Open supply valve, check for leaks, then open the tank valve. Open the faucet and let water flush. The water will initially have black activated carbon residue which will clear up in about a minute.

Membrane Replacement (ROM50)End of membrane life is indicated by increase in the permeate TDS (mineral content) or low or no product water flow.1. Shut off cold water supply and the tank valve and turn on faucet to de-pressurize unit. 2. Disconnect the following tubes from the main unit. Push the collet in with 2 fingers and pull tube out (See Fig. 2). - blue tube from faucet - grey tube from faucet - white tube from tank - red tube from saddle valve3. Loosen mounting screws and remove main unit from undersink. 4. Undo tubing on the inlet fitting (2606) of membrane housing by pressing the collet in with two fingers on either side and pull out the tubing. Unscrew membrane housing cap and using pliers, pull old membrane out of housing. 5. Unpack the new membrane and apply silicone lubricant on the two O-rings. Slide membrane into housing, "O" ring side first. (See Fig. 5). Push membrane completely in until slotted end is flush with housing opening. If you cannot push the membrane fully in, pull it out and apply some more lubricant and repeat procedure. 6. Replace housing cap. Firmly hand-tighten the cap. Insert white tubing into housing inlet fitting (2609). Push tube firmly through collet 5/8” past O-ring until it seats on tube stop. (See Fig. 2) 7. Remount main unit undersink and reconnect tubes (See Fig. 1) as follows: - red tube to filter inlet fitting (2606) - white tube to tee fitting on right end of post-filter (IM200) - grey tube to open end of drain restrictor (2611-1) - blue tube to left end of post filter (IM200) 8. Flush the unit as described previously under “Start-Up Procedure”.

System SanitizationIt is recommended to sanitize your system for general hygiene at least once a year when the pre-filters and the post filter are to be changed. Note : This procedure involves some water spillage. Keep an absorbent towel handy to clean up. Use sanitary rubber gloves for this procedure and read “warning” information on bleach container before using.1. Shut off the cold water supply and drain the storage tank by turning on the RO faucet. Once this is completed remove the pre-filters and membrane. Do not remove old post-filter at this point.2. Put 1/2 teaspoon of household bleach in 1/2 litre of water and fill the inlet filter sump, then replace both sumps and reconnect membrane housing. Open supply valve and faucet and run water until you can smell chlorine through the faucet. 3. Close faucet and supply valve and allow the bleach to remain in the system for about 4 to 5 hours. 4. Open faucet and drain tank completely. Close tank valve.5. Open supply valve and flush water out of faucet for a minute.6. Close supply valve and leave faucet on until unit de-pressurizes. Close faucet.7. Remove sumps and membrane housing cap and install membrane and pre-filters. Install new post-filter.8. Open inlet valve and check for leaks. Open tank valve. 9. Open faucet and flush for a minute. System is ready.

6.

FREQUENTLY ASKED QUESTIONS

Problem Possible Reason SolutionFaucet makes gurgling noise Drain water running from unit. This is normal when the RO is filling the storage

tank.

Water does not come out from the faucet?

1. The feed water saddle valve may be closed.2. Pre-filter may be plugged and may need replacement. 3. RO membrane may be plugged 4. Shut-off valve may be defective

1. Open feed water valve.2. Replace pre-filter3. Replace membrane4. Contact Envirogard to replace shut-off valve

Water comes out in a trickle 1. One of the above 2. The tank valve may be closed 3. The tank may have low air pressure.4. Tank may be empty

1. Solution as above OR2. Open tank valve (See Fig. 7)3. Re-pressurize tank using a bicycle pump. Drain the tank completely first and make sure that the tank pressure does not exceed the initial factory pre-set pressure.4. Wait for about an hour to allow tank to be full.

Water has a sour taste to it Your post filter may have exhausted it's life. Replace post filter

I fill up air in the pressure tank, but it reduces again.

The storage tank may have problems. Replace storage tank.

Water runs continuously down the drain and does not stop when storage tank is full.

The shut-off valve can be plugged with dirt or be faulty.

Contact Envirogard.

Water doesn't seem to go to drain? 1. The grey drain tube may be kinked or blocked.2. The drain restrictor (DR) may be clogged with dirt.

1. Take out kink. If tube is damaged or restricting flow, replace tube.2. Blow some air in the drain restrictor in the reverse direction. If you feel air at the other end, re-install. If the DR is blocked, replace.

Under-sink area is wet Possible leak in any of the fittings. Use flashlight to identify source and fix.Water comes out of drain hole in the faucet

1. 3/8” black drain tube plugged or kinked. 1. Disconnect black tube from drain saddle and inspect tube and saddle hole for plugging. Clean/replace components if necessary.

Water from faucet has air bubbles Air in system after installation or cartridge change.

Will stop after water runs for a while.

Limited 1 year WarrantyThis Envirogard system is warranted, to the original Consumer purchaser/owner, for a period of one (1) year, from the date of purchase, against defects inmaterials or workmanship. The Companies obligation under this warranty shall consist of repair, replacement or credit, at its option, of any part found by the Company inspection to be defective, provided that the product has not been misused, abused, altered or damaged as determined by the Company and provided that only approved Enivrogard/Rainfresh replacement cartridges have been used in the housings. This warranty does NOT apply to the replacement cartridge(s), membrane, or battery which by nature will diminish in performance through normal use and require(s) regular replacement. This warranty does NOT cover, and is intended to exclude, any liability on the part of Envirogard for any incidental damages, consequential damages, labour charges or any other costs incurred in connection with the purchase, installation, use, maintenance or repair of the water filter whether under this warranty or any other warranty implied by law. Some provinces/states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from province to province/state to state. This warranty applies only to water filters/systems purchased in Canada or the U.S.A.

MAINTENANCE / PRECAUTIONSCaution: If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove cartridges from sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days. Remove membrane and place it in a sealed plastic bag with a few drops of RO water and store in your refrigerator. For re-start, follow annual sanitizationprocedure.Note: Lubricate Head O-rings (2502) at least once a year or when draining for winter. Use food grade silicone grease (i.e. Dow 111 Compound) or any other non petroleum lubricant. Water conditions can be hard on rubber seals. Head O-ring replacement at least every two years is recommended to minimize wear and tear and prevent leakage.Caution: Due to a limited product service life and to prevent costly repairs or possible water damage, we strongly recommend that sumps (#520) be replaced every 5 years. If sumps of your RO system have been used for more than this period, replace immedi-ately. Date the bottom of any new sump to indicate next replacement date.Do not clean the system with organic solvents such as those found in sprays for cleaning products or insecticides as these may cause cracking or crazing and lead to failure and leakage.

7.

Envirogard Products Limited6-446 Major Mackenzie Drive East, Richmond Hill, ON L4C 1J2, Canada

Thank you for purchasing the Rainfresh Reverse Osmosis Drinking Water System. We are committed to ensuring you are totally satisfied with our product. If you have any questions don’t go back to the store. Please give us a call !

Most issues can be resolved over the phone. HELP-LINE : 1-800-667-8072 Toronto & Area : (905) 884-9388 Web Site: www.rainfresh.ca

© COPYRIGHT 2015 * ENVIROGARD PRODUCTS LIMITED * All RIGHTS RESERVED RO450/RO450M Inst E Sept/15

Parts ListPart # Item QtyHP1 Sediment Cartridge Pre Filter 1CF2 BlockActivatedCarbonPre-filter 1IM200 GranularActivatedCarbonPost-filter 1ROM50 TFC RO Membrane 50gpd 1520 Sump 21008-1 Self Piercing Saddle Valve 11008-3 1/4” Delrin Sleeve 21011-0 Bracket Screws 21030-15 1/4” Compression Nut 21603 1/4”Tube Insert 22501 Filter Head 3/8” White 22502 Head O-ring 22505 Vent Pin Assembly 22507 Head Cover plate - 1 hole 12508 Head Cover plate - no hole 12520 Monitor PCB (Model RO450M only) 12545 Battery (Model RO450M only) 12650-0 Air Gap Faucet Assembly 12650-2 Chrome Escutcheon Plate 12650-3 Escutcheon Washer 12650-4 Mounting Plate 12650-5 Spacer 12650-6 Bottom Washer 12650-7 Lock Nut 12601 Membrane Housing 12602 Base Clip 22603 Base Clip Mounting Bolt 22604 Base Clip Mounting Nut 22605 Post-Filter Double Clip 22606 1/4” QC x 3/8” FTP Acculink™ Fitting 90º 22607 Shut-off valve 1/4” QC 12609 1/4” QC x 1/8” FTP Acculink™ Fitting 90º 22610 Checkvalve 1/4” x 1/8” 90º 12613 RO450 bracket 12611-1 Capillarydrainflowrestrictor2612 Union T 1/4" QC Acculink™2614 RO450 Head Assembly complete 12615 RO450M Head Assembly complete 12616 Storage Tank (3.2 gal) w base 12617 Tank Ball Valve 1/4”QC x 1/4” FPT 12618 Drain Connector 3/8” QC 12619 Red Inlet Tube 1/4” x 3’ (See Fig.1) 12620 White Tank Tube 1/4”x 4’ (See Fig.1) 12622 BluePost-filterTube1/4”x4’(SeeFig.1) 12623 Grey Drain Tube 1/4” x 4’ (See Fig.1) 12624 Black Drain Tube 3/8” x 3’ (See Fig.1) 12626 Nitrate Test Kit 1

IM200

2601

ROM50

2602 2602 2607

2605

2612

2610

2609

2508 2520 2545

2617

2616

2618

1008-1

1008-3 1603

1030-15

2606

2606

2501 2501

2505 2507

520

CF2

2502

2613 1011-0

2604

2603

2609

2604

2603

2614 or

2615

Air gap faucetassembly complete

2650-0 2626

2611-1

HP1

Système de filtration à osmose inverse - Model RO450/RO450MGuide d’installation et d’entretien

(Gardez le guide afin de pouvoir le consulter au besoin.)

INTRODUCTIONLe système RO de Rainfresh filtre l’eau par osmose inverse (aussi appelé hyperfiltration). Ce système de filtration à quatre étapes réduit de 99 % la teneur en contaminants moléculaires et ioniques (baryum, cadmium, chrome, cuivre, fluorure, plomb, mercure, nitrate, sodium, matières totales dissoutes, chlore). Il réduit aussi le goût et l’odeur, filtre les sédiments, le limon et la rouille, et capte les sporocystes protozoaires (cryptosporidium et giardia) à plus de 99,95 %. L’eau filtrée par le système RO de Rainfresh peut être utilisée comme eau potable, pour la cuisson, la préparation du jus et des boissons et l’arrosage des plantes, ainsi que dans les fers à repasser, les humidificateurs, les aquariums, etc.DONNÉES TECHNIQUES CONCERNANT L’EAU D’ALIMENTATION(1) Si l'eau n'est pas saine du point de vue microbiologique ou si sa qualité est douteuse, il est recommandé d'installer un système de désinfection aux UV Rainfresh avant ou après le système. Mise en garde : les personnes qui ne peuvent consommer que de l'eau d'une pureté microbiologique spécifique devraient suivre les recommandations de leur docteur ou des services de santé de leur localité. (2) S’il est possible que la pression d’eau dépasse 100 lb/po2, vous devez installer un régulateur de pression en amont du système - réglage recommandé : 60 à 75 lb/po2. (3) Le système peut fonctionner si l’eau est plus dure, mais la durée utile de la membrane sera écourtée. L’alimentation en eau doit être conforme aux critères suivants. De plus, si l’eau ne répond pas aux paramètres chimiques ci-dessous, elle doit être traitée en amont du système. Eau non traitée Paramètres chimiques

Pureté bactériologique = Sans danger (1) Dureté < 170 mg/L (<10 gpg) (3) Pression = 2,8 à 7,4 kg/cm2 (2) Fer < 0,1 mg/L (ppm) (40 à 100 lb/po2) Manganèse < 0,05 mg/L (ppm) Température = 4 à 38 ºC (40 à 100 ºF) Sulfure d’hydrogène = 0,00 mg/L (ppm) pH = 3,0 à 11,0 MTD (maximum) = 1 500 mg/L (ppm) - Une pompe auxiliaire peut être requise si la teneur en MDT dépasse 1000 ppm. Appelez Rainfresh au besoin. Turbidité (maximum) = 1,0 uTN Taux de production = 66,9 L/jour (17,7 gal US) Rendement moyen : 9,1 %. Correspond au pourcentage de l’eau brute qui est traitée par le système et disponible pour l’utilisateur dans des conditions d’usage normal. Taux de récupération moyen : 18 %. Correspond au pourcentage de l’eau brute qui est disponible pour l’utilisateur lorsque le système est utilisé sans réservoir ou lorsque le réservoir est contourné. La concentration de nitrate de l’eau brute ne doit pas dépasser 27 mg/L. Ce système est certifié pour la réduction des nitrates seulement lorsque la pression de l’eau d’alimentation est de 280 kPa (40 lb/po2). Pour assurer le rendement optimal du système, les filtres doivent être remplacés aux intervalles indiqués ci-dessous : Préfiltre 1 - Modèle HP1 : Remplacer tous les six mois Préfiltre 2 - Modèle CF2 : Remplacer tous les six mois Postfiltre - Modèle IM200 : Remplacer tous les six mois Membrane - Modèle ROM50 : Remplacer tous les 1 à 4 ans REMARQUE : la durée utile des filtres et de la membrane varie selon la qualité de l'eau et le volume d'eau filtré. Il se peut que vous deviez les remplacer plus souvent s’il y a dans l’eau une concentration élevée de sédiments ou d’autres contaminants. Remarque : ce système à osmose inverse comporte une membrane remplaçable qui est essentielle à la réduction des matières totales dissoutes. Il est recommandé de faire tester par un laboratoire l’eau d’approvisionnement et l’eau traitée pour vous assurer que le système fonctionne bien. N’utilisez que la membrane RO450 pour vous assurer que l’efficacité du système et la réduction des contaminants demeurent inchangées. Réduction des nitrates Le système est livré avec un nécessaire d’analyse pour vérifier son rendement en ce qui a trait à la réduction des nitrates. L’analyse devrait être effectuée après l’installation (après avoir vidé le réservoir à 3 reprises), puis au moins tous les six mois par la suite. Instructions: le nécessaire comprend deux bandes d’essai ; vous devez utiliser une bande par analyse. Suivez les instructions figurant sur l’emballage du nécessaire. Comparez la couleur de la bande à celles qui figurent sur l’emballage ; le résultat doit être à 10 ppm près ou moins.

Testé et certifié par CSA International selon la norme CSA B483.1 et selon la norme 58 NSF/ANSI pour la réduction des matières totales dissoutes et de sodium

1.

Eau potable

La vérification de la réduction de baryum, le cadmium, le chrome, cuivre, kystes, fluorure, le plomb, le mercure, les nitrates et le sélénium a été effectuée par un laboratoire indépendant. Ne réclame pas l'exécution certifiée par CSA Internationl.

Bleu

R

limiteur de débit2611-1

2609

FAU

CET

Étape 1Étape 2

Étape 3

Étape 4

Rouge

Noir

Tubeblanc(réservoir)

Gris

MISES EN GARDE CONCERNANT L’INSTALLATION1 Le système à osmose inverse est conçu pour être installé sous l’évier, au point de distribution. 2. Comme il est possible que l’installation donne lieu à des déversements, assurez-vous d’avoir des linges à portée de la main. 3. Ce système est conçu pour être utilisé avec de l’eau froide seulement. L’eau chaude peut endommager la membrane.4. Ne tentez jamais d’utiliser le système sans les préfiltres, car vous pourriez sérieusement endommager la membrane.5. Assurez-vous que les tubes ne présentent aucun pli ni entortillement qui pourrait restreindre ou couper le débit d’alimentation.6. N’exposez pas le filtre aux rayons du soleil (ne doit pas être installé à l’extérieur). 7. N’exposez pas le système à des températures sous le point de congélation.

2.

COMMENT LE SYSTÈME FONCTIONNE ROLes flux d'eau à travers un premier sédiment 1 micron (HP1) suivi d'un filtre à charbon actif (CF2) qui réduit le chlore, le goût et odeur. La troisième et la plus importante du système est la membrane d'osmose inverse qui rejette la plupart du dissoute contaminants énumérés ci-dessus, tandis que l'eau filtrée (appelée perméat) traverse une dernière étape de polissage goût et de l'odeur, avant sortant du robinet. Comme la membrane d'osmose inverse rejette les contaminants à un niveau moléculaire, une partie de l'eau, ainsi que la contaminants, les flux vers le drain. Pour atteindre un tel filtration fine, le taux de production de l'eau est plus lent que conventionnelle sous-évier systèmes de filtration. Par conséquent, un réservoir de stockage sous pression est utilisé pour fournir de l'eau par le robinet RO à débit et pression normales.Le réservoir de stockage peut contenir un maximum de gallons US 2.2 (environ 12 litres) d'eau filtrée. Lorsque le réser-voir est plein, une boîte automatique vanne coupe l'alimentation en eau de la membrane d'osmose inverse. Que l'eau est utilisée dans le robinet et la pression dans le réservoir chute à environ 65% de la pression maximale, la fermeture automatique de soupape s'ouvre et permet à l'eau d'alimentation dans la membrane, jusqu'à ce que le réservoir de stockage est plein à nouveau. Modèle RO450M dispose également d'un moniteur électronique qui permet de suivre la vie de 6 mois filtre et clignote quand il est temps pour le poste de pré-le remplacement des filtres.

Fig. 1

INSTALLATIONOutils requis Perceuse à vitesse variable, mèches à centre plat de 3/8 et 7/8 po, couteau tout usage, deux clés à molette, lampe de poche, tournevis à lame plate et étoilée.

Raccords et tubes (voir fig. 2)À l’exception de la valve à étrier et du robinet, tous les raccordements sont effectués avec des raccords rapides Accu-LinkMC. Pour assurer l’étanchéité des joints, les tubes doivent être coupés bien droit ; si un tube est coupé en biseau ou s’il est tordu, il risque d’y avoir une fuite. Pour raccorder un tube de 1/4 po (bleu, blanc, gris ou rouge), faites une marque à 5/8 po du bout, puis enfoncez le bout du tube dans le raccord jusqu’à la marque (le bout du tube doit dépasser le joint torique et être appuyé contre la butée). Remarque : pour le tube noir de 3/8 po, faites la marque à 3/4 po du bout. Pour débrancher un tube, poussez le collet du raccord également avec deux doigts et tirez sur le tube. Coupez tous les tubes à la longueur voulue, de façon qu’ils soient juste assez longs ; tout excédent est déconseillé.

InstallationCe système comprend les filtres et les cartouches, la membrane, le robinet à écart antiretour, l’unité principale, le réservoir pressurisé, des instructions faciles à suivre et tous les raccords nécessaires à l’installation sur un tuyau de cuivre ou de PVC. L’installation comprend les étapes suivantes (installation typique illustrée à la figure 1) : 1. Installation du robinet à écart antiretour 4. Raccordement des tubes 2. Connexion au drain 5. Raccordement du réservoir 3. Installation de l’unité principale

Installation du robinet à écart antiretour (voir fig. 3)Le robinet (2600-0) peut être installé sur le comptoir ou l’évier. S’il est installé sur le comptoir, assurez-vous qu’il n’y a aucune obstruction au-dessus ni en dessous. Évier en acier émailléIl est fortement recommandé d’utiliser une scie emporte-pièce à ressort pour prévenir l’écaillement du fini émaillé. Commencez par percer un trou de 1/8 po de part en part de l’évier avec un foret carburé. Mettez de l’huile ou du savon liquide sur le foret pour l’empêcher de surchauffer. Utilisez la scie emporte-pièce à ressort pour traverser le fini émaillé seulement ; évitez les régimes élevés pour prévenir l’écaillement. Utilisez ensuite une scie emporte-pièce de 7/8 po pour couper le métal sous le fini émaillé. Évier en acier inoxydableMarquez l’emplacement du trou avec un poinçon. Percez un trou de 1/8 po avec un foret à métaux, puis agrandissez le trou avec un foret à métaux de 7/8 po. Ébarbez le trou et limez-en le pourtour. Évier en stratifié1. Percez un trou de 7/8 po à l’endroit voulu. 2. Enfilez les tubes du robinet (gris de 1/4 po et noir de 3/8 po) dans le trou, puis placez le robinet de façon que le trou de drainage soit orienté face à l’évier.3. Installez ensuite la rondelle en C (2650-4), l’entretoise (2650-5), la rondelle (2650-6) et l’écrou (2650-7). Demandez à quelqu’un de tenir le robinet pour l’empêcher de tourner pendant que vous serrez l’écrou. 4. Mettez un écrou à compression (1030-15) et une bague (1008-3) sur l’un des bouts du tube bleu (2622), puis enfoncez le manchon (1603) dans le bout du tube (voir fig. 6). Insérez le tube dans la tige filetée du robinet, puis fixez-le en place en serrant l’écrou à compression avec une clé. Ici encore, demandez à quelqu’un de tenir le robinet pour l’empêcher de tourner pendant que vous serrez l’écrou.

fig. 3

fig. 2

3.

Collet

R

2650-3

2650-2

2650-10

2650-13

Robinet à écart antiretour

2650-0

2650-4

Comptoir

2650-5

2650-62650-716031008-31030-15Écrou à compression

BagueManchon

ÉcrouRondelle

Entretoise

Rondelle en C

Rondelle d’écusson

Écusson

Levier

Ensembletige

Connexion au drain1. Marquez l’emplacement de la connexion sur le tuyau du drain, puis percez un trou de 3/8 po, préférablement face au robinet. Assurez-vous de ne pas percer le tuyau de part en part. 2. Enlevez la pellicule protectrice du joint en mousse, et posez ce dernier sur la face interne du raccord à étrier (2618). Assurez-vous que le trou du joint est vis-à-vis le trou du raccord à étrier 3. Installez le raccord à étrier sur le tuyau du drain en prenant soin d’aligner le trou du raccord avec le trou de 3/8 po que vous avez percé dans le tuyau. Si nécessaire, utilisez une lampe de poche et un foret pour vous assurer que les trous sont bien alignés. Fixez le raccord à étrier en serrant les écrous (ne pas trop serrer) (voir fig. 4).4. Déterminez la longueur que le tube noir (2624) doit avoir pour atteindre le raccord à étrier. Attention : il s’agit d’un tuyau à écoulement libre qui doit être aussi court que possible, sans quoi il pourrait y avoir une fuite au trou de drainage du robinet (voir fig. 1). Coupez le tube à la longueur voulue et branchez-le au raccord à étrier (faites une marque à 3/4 po du bout, enfoncez le bout dans le raccord jusqu'à la marque, de façon que le bout du tube dépasse le joint torique et soit appuyé contre la butée) (voir fig. 2).

Installation de l’unité principaleL’unité principale doit être installée sous l’évier, à proximité du robinet. REMARQUE : laissez au moins 5 po sous les carters des préfiltres pour faciliter le remplacement des cartouches. Pour faciliter l’entretien du système, il est préférable d’installer l’unité le plus haut et le plus en avant possible. 1. Déballez l’unité et tirez le postfiltre (IM200) vers l’avant pour exposer le support de montage (2613). Servez-vous du support de montage pour marquer l’emplacement des trous de fixation. Mettez l’unité de côté.2. Vissez partiellement les deux vis de fixation (1011-0) dans les trous. REMARQUE : si le mur est trop mince pour des vis, utilisez des boulons et des écrous (non compris). Installez les préfiltres et la membrane sur l’unité avant de frixer cette dernière au mur. 3 Installation des préfiltres : a) Tournez les carters (520) de 1/8 de tour vers la gauche et enlevez-les de la tête (2501). b) Retirez les cartouches HP1 et CF2 de la tête pour les déballer, puis réinstallez-les, l’extrémité ouverte sur le raccord de la tête. c) Pour réinstaller les carters, alignez les rainures des carters avec les ergots de la tête, et poussez les carters contre la tête du filtre. Bloquez les carters en place en les tournant de 1/8 de tour vers la droite. 4. Installation de la membrane (voir fig. 5) Pour faciliter l’installation de la membrane, le tube est débranché du couvercle de la membrane (2601). a) Dévissez et enlevez le couvercle du carter de la membrane. b) Sortez la membrane (ROM50) du sac et mettez du lubrifiant à la silicone (inclus) sur les deux joints toriques. Attention : n’utilisez aucun autre lubrifiant. c) Mettez la membrane dans le carter, le bout avec joints toriques en premier. Enfoncez-la dans le carter jusqu’à ce que le bout rainuré soit à égalité avec l’ouverture du carter. Si vous n’arrivez pas à l’enfoncer complètement, ressortez-la, remettez du lubrifiant et essayez de nouveau. d) Réinstallez le couvercle du carter en vous assurant que le joint torique est bien en place. Serrez fermement le couvercle à la main. e) Branchez le tube blanc au raccord du couvercle (2609). Faites une marque à 5/8 po du bout, enfoncez le bout dans le raccord jusqu'à la marque, de façon que le bout du tube dépasse le joint torique et soit appuyé contre la butée (voir fig. 2). 5. Installation de la pile du dispositif de contrôle (modèle RO450M) a) Enlevez le couvercle (2508) de la tête du préfiltre en le soulevant avec les ongles. b) Déballez la pile (2545), mettez-la dans le compartiment, la borne positive (+) sur le dessus, puis remettez le couvercle. Appuyez sur le bouton noir jusqu’à ce que le témoin orange clignote quatre fois. Le dispositif est alors initialisé et prêt à l’emploi. 6. Installez l’unité principale sur les vis de fixation, puis serrez ces dernières.7. Coupez le tube gris (2623) du robinet à la longueur requise pour le brancher à l’extrémité libre du régulateur de drainage (2611-1) (voir fig. 1). Faites une marque à 5/8 po du bout et enfoncez le bout dans le raccord jusqu'à la marque (voir fig. 2).8. Coupez le tube bleu (2622) du robinet à la longueur requise pour le brancher au raccord de sortie du postfiltre (IM200) (voir fig. 1). Faites une marque à 5/8 po du bout et enfoncez le bout dans le raccord jusqu'à la marque (voir fig. 2).

4.

fig. 4

fig. 5

Installation de la valve à étrier REMARQUE : la valve à étrier (1008-1) peut être installée sur un tuyau de cuivre ou de plastique CPVC rigide mesurant de 3/8 à 1 po de diamètre (non recommandée pour les tuyaux en plastique flexible). REMARQUE : si la conduite d'eau froide n'est pas conforme à la description ci-dessus, utilisez des raccords de façon à l'adapter pour un raccord à compression de 3/8 po (non compris), ou communiquez avec Envirogard.IMPORTANT : placez la valve à étrier de façon à orienter les filets en direction du raccord d'entrée (INLET - 2606) (voir fig. 1). 1. Tourner la poignée sur la valve à étrier pour faire rentrer la pointe taraudeuse. Le joint en caoutchouc étant en position fixe, fixez l'ensemble sur le tuyau à l'aide des boulons fournis. Vissez les boulons, en gardant les supports parallèles, jusqu'à ce que le joint en caoutchouc soit fermement comprimé. Attention : ne pas trop serrer les boulons. 2. Mesurez la distance entre la valve à étrier et le raccord d'entrée, puis coupez le tube rouge (2619) de façon qu’il ne puisse être plié. 3. Glissez l'écrou à compression (1030-15) et la bague (1008-3) sur le tube, puis mettez le manchon (1603) au bout du tube (voir fig. 6). Enfoncez le tuyau dans le raccord de la soupape à étrier et tenez-le fermement en place. Ensuite, serrez bien l'écrou tout en tenant l'autre bout du raccord avec une clé.

Raccordement du réservoir

1. Placez le réservoir sur son socle, sous l’évier. La valve (2617) et le tube blanc (2620) sont déjà branchés au réservoir. 2. Branchez l’extrémité libre du tube blanc (2620) au raccord en T (2612), du côté droit du postfiltre (IM200). Faites une marque à 5/8 po du bout, enfoncez le bout dans le raccord jusqu'à la marque (voir fig. 2).MISE EN SERVICE1. Tournez complètement la manette de la valve à étrier en sens horaire. VOUS VENEZ DE PERCER LE TUYAU ET DE FERMER LA VALVE. 2. Rétablissez l’alimentation en eau en ouvrant la valve d’eau froide sous l’évier ou la valve principale de la maison, puis vérifiez s’il y a des fuites. Tournez la manette de la valve à étrier en sens antihoraire pour permettre à l'eau de circuler. Vérifiez l’étanchéité de tous les raccords. 3. Tournez la manette du réservoir d’un quart de tour en sens antihoraire pour l’ouvrir (la manette devrait être alignée avec le raccord du tube ; voir fig. 7). 4. Le système est maintenant en service.REMARQUE : vous devez purger le réservoir trois fois avant de consommer l’eau du système (instructions ci-dessous). REMARQUE : il est normal que vous entendiez de l’eau couler dans le drain lorsque le système filtre l’eau. Purge du réservoir Laissez le réservoir se remplir (le remplissage peut prendre de 2 à 5 heures selon la pression de la source d’alimentation). Pour ce faire, laissez le réservoir se remplir pendant 2 ou 3 heures. Ouvrez le robinet et rincer le réservoir jusqu'à ce que l'eau du robinet ralentit à un filet. Répétez deux fois. Après cela, vous pouvez con-sommer l’eau du système. UTILISATION EN ENTRETIENFonctions du dispositif de contrôle électronique (modèle RO450M)Après six mois, le témoin orange du dispositif de contrôle électronique se met à clignoter pour vous rappeler qu’il est temps de remplacer les préfiltres (HP1 et CF2) et le postfiltre (IM200). Le dispositif de contrôle ne mesure pas la durée utile de la membrane d’osmose inverse. Initialisez le dispositif avant la mise en service, et réinitialisez-le chaque fois que vous remplacez les filtres.

Initialisation et ré-initialisation du dispositif de contrôle (voir fig. 8) Appuyez sur le bouton noir jusqu'à ce que le témoin orange clignote quatre fois. Le dispositif est alors initialisé et commence à compter le temps. Après six mois, le témoin orange clignote toutes les cinq sec-ondes, indiquant que vous devez remplacer les filtres.

Durée utile de la pile - Environ quatre ans. Pour vérifier l’état de la pile, appuyez sur le bouton noir pendant pendant deux secondes ou moins. Si le témoin orange s’allume, la pile est bonne ; s’il ne s’allume pas, la pile doit être remplacée. Enlevez le couvercle de la tête du préfiltre en le soulevant avec les ongles. Retirez la vieille pile et installez la nouvelle (2545) dans le compartiment, la borne positive (+) sur le dessus. Remettez le couvercle.

5.

Fig. 6

Fig. 7

Fig. 8

Attention : ne modifiez pas la soupape à air du réservoir. Elle a été préréglée à l’usine à 5-6 lb/po2 pour assurer le rendement optimal du système.

Fréquence de remplacement des filtres et de la membranePour assurer le rendement optimal du système, les filtres et la membrane doivent être remplacés aux intervalles suivants : Préfiltre 1 : HP1 : Tous les six mois Préfiltre 2 : CF2 : Tous les six mois Postfiltre : IM200 : Tous les six mois Membrane : ROM50 : Tous les deux à quatre ans REMARQUE : la durée utile des filtres et de la membrane varie selon la qualité de l'eau et le volume d'eau filtré. Il se peut que vous deviez les remplacer plus souvent s’il y a dans l’eau une concentration élevée de sédiments ou d’autres contaminants. Attention : comme il est possible que l’entretien du système donne lieu à des déversements, assurez-vous d’avoir des linges à portée de la main.

Remplacement des préfiltres (HP1 et CF2)1. Coupez l’alimentation en eau, fermez la valve du réservoir et ouvrez le robinet pour dépressuriser le système. 2. Enlevez le carter en le tournant de 1/8 de tour vers la gauche et enlevez la vieille. Installez la nouvelle cartouche et réinstallez le carter en le tournant de 1/8 de tour vers la droite. 3. Rétablissez l’alimentation en eau, vérifiez s’il y a des fuites, puis ouvrez la valve du réservoir. Remplacement du postfiltre (IM200) 1. Coupez l’alimentation en eau, fermez la valve du réservoir et ouvrez le robinet pour dépressuriser le système. 2. Aux deux extrémités du postfiltre, poussez le collet du raccord également avec deux doigts et tirez sur le tube (voir fig. 2). 3. Retirez le postfiltre des supports (2605). Installez le nouveau postfiltre sur les supports en vous assurant que la flèche du filtre pointe vers la gauche.4. Rebranchez les tubes dans les raccords en les enfonçant de 5/8 po (voir fig. 2).5. Rétablissez l’alimentation en eau, vérifiez s’il y a des fuites, puis ouvrez la valve du réservoir. Ouvrez le robinet et laissez couler l’eau pendant environ une minute, ou jusqu’à ce qu’il n’y ait plus de particules de charbon actif dans l’eau. Remplacement de la membrane d’osmose inverse (ROM50)La membrane doit être remplacée lorsqu’il y a une augmentation de la teneur en minéraux dans l’eau filtrée ou qu’il n’y a presque plus d’eau qui sort du robinet. 1. Coupez l’alimentation en eau, fermez la valve du réservoir et ouvrez le robinet pour dépressuriser le système. 2. Débranchez les tubes suivants (poussez le collet du raccord et tirez sur le tube - voir fig. 2). - le tube bleu du robinet - le tube gris du robinet - le tube blanc du réservoir - le tube rouge de la valve à étrier 3. Desserrez les vis de fixation et sortez l’unité principale de l’armoire. 4. Débranchez le tube du raccord d’entrée (2606) du carter de la membrane en poussant le collet du raccord et en tirant sur le tube (voir fig. 2). Dévissez le couvercle du carter de la membrane et sortez cette dernière en la saisissant avec des pinces. 5. Déballez la nouvelle membrane et mettez du lubrifiant à la silicone sur les deux joints toriques. Mettez la membrane dans le carter, le bout avec joints toriques en premier (voir fig. 5). Enfoncez-la dans le carter jusqu'à ce que le bout rainuré soit à égalité avec l'ouverture du carter. Si vous n'arrivez pas à l'enfoncer complètement, ressortez-la, remettez du lubrifiant et essayez de nouveau. 6. Réinstallez le couvercle du carter en vous assurant que le joint torique est bien en place. Serrez fermement le couvercle à la main. Branchez le tube blanc au raccord du couvercle (2609) (voir fig. 2).7. Réinstallez l’unité principale et rebranchez les tubes en procédant comme suit : - le tube rouge au raccord d’entrée (2606) - le tube blanc tube au raccord en T du postfiltre (IM200) - le tube gris au bout libre du régulateur de rainage (2611-1) - le tube bleu au raccord gauche du postfiltre (IM200) 8. Purgez le système tel que décrit dans la section MISE EN SERVICE.

Désinfection du systèmeIl est recommandé de désinfecter le système au moins une fois par année, lorsque vous remplacez les préfiltres et le postfiltre. Remarque : comme la désinfection du système donne lieu à des déversements, assurez-vous d’avoir des linges à portée de la main. Utilisez des gants en caoutchouc et lisez les mises en garde du contenant d’eau de javel avant de procéder. 1. Coupez l’alimentation en eau et purgez le réservoir en ouvrant le robinet du système. Une fois le réservoir vide, enlevez les préfiltres et la membrane ; n’enlevez pas le postfiltre pour l’instant. 2. Mettez 1/2 cuillère à thé d’eau de javel dans 500 mL d’eau, puis versez le mélange dans le carter du premier préfiltre. Réinstallez les deux carters de préfiltre et rebranchez le carter de la membrane. Rétablissez l’alimentation en eau, ouvrez le robinet du système et laissez couler l’eau jusqu’à ce que vous sentiez une odeur de chlore au robinet. 3. Refermez le robinet, coupez l’alimentation en eau et laissez l’eau de javel dans le système pendant quatre à cinq heures. 4. Ouvrez le robinet et videz le réservoir. Fermez la valve du réservoir.5. Rétablissez l’alimentation en eau, ouvrez le robinet du système et laissez couler l’eau pendant une minute.6. Coupez l’alimentation en eau et laissez le robinet ouvert pour dépressuriser le système. Fermez le robinet. 7. Enlevez les carters et le couvercle du carter à membrane, puis installez la membrane et les nouveaux préfiltres. Remplacez le postfiltre. 8. Rétablissez l’alimentation en eau et vérifiez s’il y a des fuites. Ouvrez la valve du réservoir. 9. Ouvrez le robinet et laissez l’eau couler pendant une minute. Le système est prêt à être utiliser.

6.

GUIDE DE DÉPANNAGE

Problème Cause possible SolutionLe robinet fait un bruit de gargouillement.

L’eau rejetée coule dans le drain. Ce bruit est normal pendant que le système remplit le réservoir.

Il n’y a pas d’eau qui coule du robinet. 1. La valve à étrier est fermée. 2. Les préfiltres sont obstrués ou usés. 3. La membrane est obstruée. 4. La valve automatique est défectueuse.

1. Ouvrir la valve.2. Remplacer le ou les préfiltres.3. Remplacer la membrane.4. Communiquer avec Envirogard pour faire remplacer la valve automatique

L’écoulement d’eau traitée est insuffisant.

1. Voir ci-dessus. 2. La valve du réservoir est fermée. 3. La pression du réservoir est insuffisante. 4. Le réservoir est vide.

1. Voir ci-dessus.2. Ouvrir la valve du réservoir (voir fig. 7).3. Pressuriser le réservoir avec une pompe à vélo. Vider d’abord le réservoir et s’assurer que la pression ne dépasse pas 5 lb/po2.4. Attendre que le réservoir se remplisse (environ une heure).

L’eau a un goût amer. Le postfiltre doit être remplacé. Remplacer le postfiltre

Le réservoir ne demeure pas pressurisé.

Le réservoir est défectueux. Remplacer le réservoir.

De l’eau coule continuellement dans le drain, même lorsque le réservoir est plein.

La valve automatique est bouchée ou défectueuse.

Communiquer avec Envirogard.

L’eau rejetée ne semble pas aboutir au drain.

1. Le tube gris est bouché ou plié.2. Le régulateur de drainage est bouché.

1. Déplier ou déboucher le tube. Le remplacer s’il est endommagé. 2. Souffler dans le régulateur de drainage dans la direction opposée au débit ; s’il n’y a pas d’air qui sort à l’autre bout, remplacer le régulateur.

Il y a de l’eau sous l’évier. Un des raccords du système fuit. Réparer la fuite. De l’eau coule du trou de drainage du robinet.

1. Le tube noir est bouché ou plié. 1. Débrancher le tube noir du raccord à étrier et vérifier s’il y a une obstruction. Déboucher ou remplacer au besoin.

Il y a des bulles dans l’eau qui coule du robinet.

De l’air s’est infiltré dans le système lors d’un changement de cartouche.

Laisser couler l’eau pendant un moment.

Garantie limitée d’un anCe système de filtration Envirogard est garanti contre les défauts de matériaux et de fabrication pendant une période d'un (1) an à compter de la date d'achat. La garantie n'est valide que pour l'acheteur initial. Aux termes de la présente garantie, la responsabilité d'Envirogard se limite à la réparation ou au remplacement (à sa discrétion) de toute pièce qu'elle juge défectueuse, pourvu que le système n'ait pas été utilisé de façon incorrecte ni abusive, qu'il n'ait pas été modifié ni endommagé par l'utilisateur, et qu'il ait été utilisé avec des cartouches Envirogard/Rainfresh. Cette garantie ne couvre pas les cartouches de rechange, la membrane ni la pile du dispositif de contrôle. Leur rendement diminue à la longue et elles doivent être remplacées à intervalles réguliers. Aux termes de la présente garan-tie, Enviroguard ne peut être tenue responsable d'aucun dommage indirect, y compris les frais de main-d'œuvre et tout autres frais découlant de l'achat, de l'installation, de l'entretien ou de la réparation du système. Comme certaines provinces ne permettent pas l'exclusion des dommages indirects, il se peut que la restriction ci-dessus ne s'applique pas à vous. La présente garantie vous donne des droits spécifiques, et il se peut aussi que vous ayez d'autres droits selon votre province de résidence. La présente garantie ne couvre que les systèmes qui sont achetés au Canada et aux États-Unis.

ENTRETIEN ET PRÉCAUTIONSAttention : si le système n’est pas utilisé en hiver, ou si vous croyez qu’il pourrait être exposé à des températures sous le point de congélation, videz-le et retirez les cartouches des carters. Mettez les cartouches dans l’évier ou sur un essuie-tout pour les laisser sécher, ce qui peut prendre plusieurs jours. Retirez la membrane et mettez-la dans un sac avec quelques gouttes d’eau traitée par le système, scellez-le sac et rangez-le dans le réfrigérateur. Au moment de remettre le système en service, faites-en la désinfection.Remarque : lubrifiez les joints toriques des têtes (2502) au moins une fois par année, ou lorsque vous videz le système pour l’hiver. Utilisez un lubrifiant alimentaire ou tout lubrifiant qui n’est pas à base de pétrole. Il est recommandé de remplacer les joints toriques aux deux ans à tout le moins pour prévenir les fuites. Attention : pour aider à prévenir les dommages causés par les fuites d'eau, il est fortement recommandé de remplacer les carters (520) tous les cinq ans. Si les carters ont plus de cinq ans, remplacez-les immédiatement. Indiquez la date d'installation des nouveaux carters pour savoir quand les remplacer à nouveau. Ne nettoyez pas le système avec des solvants organiques comme ceux que l'on trouve dans les produits de nettoyage à vaporiser ou les insecticides, car ces produits pourraient causer des fissures et des fuites.

7.

Envirogard Products Limited6-446 Major Mackenzie Drive East, Richmond Hill (Ontario) L4C 1J2, Canada

Nous vous remercions d'avoir acheté un système de filtration à osmose inverse Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si le système vous cause un problème, ne

retournez pas au magasin, appelez-nous ! La plupart des problèmes peuvent être résolus au téléphone.

Assistance-clients : 1 800 667-8072 Toronto et la région : (905) 884-9388 Site web : www.rainfresh.ca

© 2015 * ENVIROGARD PRODUCTS LIMITED * TOUS DROITS RÉSERVÉS RO450/RO450M Inst F Sept/15

LISTE DES PIÈCESNuméro Désignation Qté

HP1 Cartouche pour sédiment 1

CF2 Cartouche au charbon actif 1

IM200 Postfiltreaucharbonactifgranulé 1

ROM50 Membrane d’osmose inverse 50 gal/jour 1

520 Carter 2

1008-1 Valve à étrier 1

1008-3 Bague en Delrin, 1/4 po 2

1011-0 Vis de support 2

1030-15 Écrou à compression, 1/4 po 2

1603 Manchon, 1/4 po 2

2501 Têtedefiltreblanche,3/8po 2

2502 Joint torique 2

2505 Bouton de purge 2

2507 Plaque de tête (1 trou) 1

2508 Plaque de tête (pas de trou) 1

2520 Dispositif de contrôle (RO450M seulement) 1

2545 Pile (RO450M seulment) 1

2650-0 Robinet à écart antiretour 1

2650-2 Écusson chromé 1

2650-3 Rondelle d’écusson 1

2650-4 Rondelle en C 1

2650-5 Entretoise 1

2650-6 Rondelle 1

2650-7 Écrou 1

2601 Carte de membrane 1

2602 Support de membrane 2

2603 Boulon de support 2

2604 Écrou de support 2

2605 Supportdepostfiltre 2

2606 Coude Acculink, 1/4 x 3/8 po 2

2607 Valve automatique, 1/4 po 1

2609 Coude Acculink, 1/4 x 1/8 po 2

2610 Clapet antiretour, 1/4 x 1/8 po 1

2611-1 Régulateur de drainage 1

2612 Té Acculink, 1/4 po 1

2613 Support de montage 1

2614 Unité principale RO450 1

2615 Unité principale RO450M 1

2616 Réservoir avec socle, 3,2 gal 1

2617 Valve de réservoir, 1/4 po x 1/4 po 1

2618 Raccord à étrier, 3/8 po 1

2619 Tuberouge,1/4pox3pi(fig.1) 1

2620 Tubeblanc,1/4pox3pi(fig.1) 1

2622 Tubebleu,1/4pix3pi(fig.1) 1

2623 Tubegris,1/4pox3pi(fig.1) 1

2624 Tubenoir,3/8pix3pi(fig.1) 1

2626 L’Exécution de Réduction de nitrate 1

IM200

2601

ROM50

2602 2602 2607

2605

2612

2610

2609

2508 2520 2545

2617

2616

2618

1008-1

1008-3 1603

1030-15

2606

2606

2501 2501

2505 2507

520

CF2

2502

2613 1011-0

2604

2603

2609

2604

2603

2614 or

2615

2626

2611-1

HP1

Robinet àécart antiretour

avec piècesconnexes

2650-0