roofing solutions for cold formed steel construction
TRANSCRIPT
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
1/12
www.framecad.com
Roofing Solutionsfor Cold Formed Steel Construction
Roofing Solutions
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
2/12
FRAMECAD 2013
FRAMECADMetal Roof Tile offer:
1. Minimum order quanity: one 20 container(approximately 8,000 pieces for Stone Coated Tiles and Approximately 11,000 pieces for PVC Painted Tiles)
2. Lead Time a. Less than 2 colours : 2-3 weeks b. More than 2 colours : 2-4 weeks
3. Payment Terms: 100% payment prior to delivery by T/T remittance (or by negotiation)
Packaging
1. Minimum 500 pieces per pallet Maximum 16 pallets per 20 container
2. Pallet dimensions approximately 1000mm (Width) x 1200mm (Length) x 1000mm (Height)
3. Storage: All products should be stored indoors or undercover.
Structure of FRAMECADMetal Roof Tiles
Acrylic Top Coat
Stone Chip
Acrylic Base Coat
Organic Coat
AL - Zinc Coat
Base Steel
AL - Zinc Coat
Organic Coat
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
3/12
FRAMECAD 2013 1
FRAMECAD- GRAND
Red
Silver Grey
Terracotta
Teak
Brown Bark
Sapphire Black
25mm25mm
395mm
Item Dimensions
Overall length 1345mm
Length of cover 1280mmWidth of cover 370mm
Upstand 25mm
Roof Cover 0.473m2
Tiles 2.1m2
Weight 2.6 - 2.7kg
Minimum Tile Pitch 15 degrees
Packing 8,000 Tiles / 1 x 20 container
320mm 320mm 320mm 320mm
25mm
370mm
Screw / Nailing Position
1345mm
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
4/12
2 FRAMECAD 2013
25mm25mm
420mm
Item Dimensions
Overall length 1285mm
Length of cover 1215mmWidth of cover 380mm
Upstand 25mm
Roof Cover 0.4617 m2
Tiles 2.17m2
Weight 2.5 - 2.6kg
Minimum Tile Pitch 15 degrees
Packing 8,000 Tiles / 1 x 20 container
FRAMECAD- VENETIAN
Terrecotta
Brown Bark
Red
Screw / Nailing Position
1285mm
300mm250mm250mm440mm
380mm
25mm
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
5/12
FRAMECAD 2013 3
Item Dimensions
Overall length 1335mm
Length of cover 1280mmWidth of cover 370mm
Upstand 25mm
Roof Cover 0.473m2
Tiles 2.1m2
Weight 2.6 - 2.7kg
Minimum Tile Pitch 15 degrees
Packing 8,000 Tiles / 1 x 20 container
25mm25mm
415mm
Brown Bark
Charcoal
Teak
Red
Sapphire Black
Terracotta
FRAMECAD- WOODGRAIN
320mm320mm320mm320mm
Screw / Nailing Position
370mm
1335mm
25mm
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
6/12
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
7/12
5 FRAMECAD 2013
INSTALLATION
Please Note:Avoid fastening in places with electrical wiring above and below.Apply fasteners with a sealing washer in the upcurve as marked in red above
When screwing in fasteners, always face the eaves while standing on top of the tiles
being installed. Ensure fastenings are positioned on the crest above pan not in water channel.In high winds or coastal regions, use a minimum of 6 fasteners per tile.After fastening, in order to prevent water damage always use an adhesive / sealant to finish.
With Batten
Use 50mm fastener
Roof Tile Spacing
330mm 365mm 365mm 365mm
Changing Pitch
365mm
365mm
365mm365mm
Rafter
Rooftile
Batten
330mm 365mm 365mm 365mm
Gutter Installation Fascia Installation
Fixing locations
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
8/12
6 FRAMECAD 2013
INSTALLATION - Tile Lapping
Tile B overlaps tile A End of tile A
fastening placement
Dover tile
Tile B overlaps tile A
(Overlap)End of Tile A
fastening placement
Tile B overlaps tile A
(Overlap)
End of Tile A
A
fastening placement
B
A BA B
Venetian tile
A B fasteningplacement
Tile B overlaps tile A
(Overlap)
End of Tile A
Woodgrain tile
INSTALLATION - Fasica Flashings
fastening with
sealing washer
Gutter
Fascia
Batten
Rafter
Gutter system Fascia Flashing Fascia and Gutter system
Fascia
Batten
Rafter
Fascia
Batten
Rafter
fastening with
sealing washerfastening with
sealing washer
A
Grand tile
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
9/12
7 FRAMECAD 2013
INSTALLATION - Valleys
INSTALLATION - Barge BoardsWhen using side flashing install the batten above the rafter and match the top of the barge board to the top of
the batten. The edge of the steel roof tiles must be bent up so that the part tucked into the side flashing is longenough to prevent water ingress / damage.
Barge Board Flashing
Barge Board
Roof Tile Flashing
Barge Board
Rafter
BattenRoof Tile
Valley
Screw position
Finish Tile LineRoof Tile
Valley
Batten
Valley
Screw position
Batten
Batten
Batten
Roof Tile
Valley
Roof Tile
Valley
Roof Tile
Screw
Bend Line Cutting Line
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
10/12
- V- Ridge / Hip
Ridge / Hip Ridge / Hip cap
Barge board flashing
overall length 1,340mm
length of cover 1,300mm
92mm
- Half round ridge/hip
400mm140mm
94mm
150mm
400mm
110mm
160mm
-Half round Ridge / Hip Cap
- 001236 FRAMECADX-Drive
10g x 19mm X Drive , Sharp Point
8
FRAMECAD 2013
160mm 145mm
- V-Ridge / Hip Cap
180mm
Side flashing
overall length 1,340mm
length of cover 1,300mm
12mm
20mm
1340mm
50mm
60mm
Flat sheet
overall length 1,340mm (5mm)
1340mm
457mm
1340mm
60mm
180mm
12mm
30mm
Fascia flashing
overall length 1,340mm
length of cover 1,300mm
1340mm
12mm
150mm
12mm
Valley
overall length 1340mm
1340mm
20mm
40mm
92mm
Shackle
overall length 970mm
height 55.8mm
970mm55.8mm
Closer
overall length 970mm
height 34.8mm
970mm
55.8mm
160mm
RG-Ridge/hip , V-Ridge
overall length 1,340mm
length of cover 1,300mm
-RG-Ridge/hip - V-Ridge
150
1340mm
92mm
1340mm
20mm
40mm
50mm65mm
12mm
FINISHING
Fastenings
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
11/12 FRAMECAD 2013
Notes:
-
8/11/2019 Roofing Solutions for Cold Formed Steel Construction
12/12
We have offices here:
Auckland, New Zealand (Head Office)
Dubai, UAEDallas, USAHong Kong
Melbourne, AustraliaJohannesburg, South AfricaPort Harcourt, Nigeria
www.framecad.com
Roofing Tiles - British English 2013
This document has been published forthe purpose of providing informationof a general nature only. Further, noguarantee, warranty, or any otherform of assurance is given as to theaccuracy, currency or completeness ofthe information provided. Accordingly,any reliance on, or use, by you of any
information contained within thisdocument for any purpose whatsoevershall be entirely at your own risk, and anyliability to you is expressly disclaimed tothe maximum extent permitted by law.
FRAMECADLtd , logos and Trademarksare the property of FRAMECAD Ltd.
Copyright 2013 FRAMECADLtd.
Reproduction of any part of thisdocument is prohibited, except with theprior written consent of FRAMECADLtd.