GENERAL NOTES
SEALS
LOCATION MAP ABBREVIATIONS PROJECT INFORMATION
DRAWING INDEX OWNER'S REPRESENTATIVEPROJECT TEAMPROJECT MANUAL WITH SPECIFICATIONS AND SPECIFIC PRODUCT DETAILS SHALL BE DISTRIBUTED WITH THIS SET OF DRAWINGS ASPART OF THE CONTRACT DOCUMENTS. PLEASE REVIEW THIS DOCUMENT IN ITS ENTIRETY AS A SUPPLEMENT TO THE INFORMATIONCONTAINED IN THIS SET.
KEY PLAN
AMERICANRENAL a s s o c i a t e sLincoln Park Kidney Center, LLC
1491 Southfield RoadLincoln Park, MI 48146
@ ATACOUS. ACOUSTICALADJ. ADJUSTABLEAL. OR ALUM. ALUMINUMA.F.F. ABOVE FINISHED FLOORANOD. ANODIZEDB.L. BRICK LEDGEBITUM. BITUMINOUSBLDG. BUILDINGBD. BOARDBRG. BEARINGBUS/RCPT BUSINESS/RECEPTIONBOT BOTTOM OF TRUSSC CONDUITCAB. CABINETCI CAST IRONCER. T. CERAMIC TILECH COAT HOOKCJ CONTROL JOINTCKT. CIRCUITCL CARPET LINECLG. CEILINGCLO. CLOSETCMU CONCRETE MASONRY UNITSCNTR. COUNTERCOL. COLUMNCONC. CONCRETECONN. CONNECTIONCONS. CONSULATION/OFFICECONT. CONTINUOUSCONTR. CONTRACTORCORR. CORRIDORCP CHROME PLATEDCR CRASH RAILCRS COURSECSBA COLOR SELECTED BY
ARCHITECTCT CURTAIN TRACKCTR. COUNTERCU COPPERDAPW DENS ARMOR PLUS
WALLBOARDDFP DRY FOG PAINTDN. DOWNDWG. DRAWINGEC ELECTRICAL CONTRACTOREDF ELECTRIC DRINKING
FOUNTAINEGG EGGSHELL PAINTEUH ELECTRIC UNIT HEATEREWH ELECTRIC WALL HEATERELECT. ELECTRICEJ EXPANSION JOINTEA. EACHEL. ELEVATIONELEV. ELEVATOREMERG. EMERGENCYEP END PANELES END SUPPORTEQUIP. EQUIPMENTEXIST. EXISTINGEXT. EXTERIOREXAM EXAMINATION
EXP. EXPANSIONFACP FIRE ALARM CONTROL PANELFBO-IBC FURNISHED BY OWNER -
INSTALLED BY CONTRACTORFD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFG FIXED GLASSFHC FIRE HOSE CABINETFIN. FINISHEDFLR. FLOORFUT. FUTUREFTG. FOOTINGFURR. FURRINGGA. GAUGEGALV. GALVANIZEDGB GRAB BARGC GENERAL CONTRACTORGWB GYPSUM WALLBOARDGYP GYPSUMHDCP. HANDICAPPEDHDR. HEADERHM HOLLOW METALHR. HOURHGT. HEIGHTHVAC HEATING VENTILATING & AIR
CONDITIONINGID INSIDE DIAMETERIE INVERT ELEVATIONINSUL. INSULATIONJB JUNCTION BOXJST. JOISTKS KNEE SPACEKW KILOWATTLAB LABORATORYLGW LEAD GLASS WINDOWLL LEAD LINEDLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLP LIGHTPROOFMAX. MAXIMUMM MIRRORME MECHANICAL CONTRACTORMFR. MANUFACTURERMIN. MINIMUMM.0. MASONRY OPENINGMRGWB MOISTURE RESISTANT GYPSUM
WALLBOARDM/S MIRROR & SHELFMTP METAL TOILET PARTITIONM/SURG. MINOR SURGERYMTG. MOUNTINGNEC NATIONAL ELECTRICAL CODENIC NOT IN CONTRACTN/S NURSE STATIONO.C. ON CENTERO.D. OUTSIDE DIAMETERO.F. OVERFLOWO.F.I.C. OWNER FURNISHED,
INSTALLED BY CONTRACTOROFC. OFFICEOPP. OPPOSITE HANDOTS OPEN TO STRUCTURE
PA PARTITION ANCHORP.H. PANIC HARDWAREPB PASS BOXPC PLUMBING CONTRACTORPD PENCIL DRAWERPD PERITONEAL DIALYSISPL PLATEPLS PLASTIC LAMINATE SHELFPTD. PAINTEDPLWD. PLYWOODPT PRESSURE TREATEDQT. QUARRY TILERD ROOF DRAINREF. REFRACTORYREFR. REFRIGERATORREF. SP. REFRIGERATOR SPACEREINF. REINFORCINGRM. ROOMR.O. ROUGH OPENINGR&S ROD & SHELFRSA RENTAL SUITE AREARX PRESCRIPTION DESKSIM. SIMILARSHT. SHEETSFT. SOFFITSG SEMI-GLOSS PAINTSGW SLIDING GLASS WINDOWSH. SHELFSP SUPPORT BRACKETS/P SPECIAL PROCEDURESTL. STEELSTRUCT. STRUCTURALSS STAINLESS STEELSSP SCALE SPACESV SHEET VINYLSURG. SURGICALTC TUBE COLUMNTOC TOP OF COLUMNTEL. TELEPHONET&P TEMPERATURE & PRESSURETEMJ TOP ELEVATION MATCHES JOISTTOS TOP OF STEELTLT. TOILETTW TYPEWRITER SPACETYP. TYPICALUL UNDERWRITERS
LABORATORIESURS UNDERCOUNTER
REFRIGERATOR SPACEUNO UNLESS NOTED OTHERWISEVWC VINYL WALL COVERINGVB VIEW BOXVERT. VERTICALV.I.F. VERIFY IN FIELDW/ WITHWDW. WINDOWWG WIRE GLASSWL WARNING LIGHTWP WEATHERPROOFWWM WELDED WIRE MESHW.D. WRITING DESK
XFMR. TRANSFORMER
PROJECT SITE
CKA Principal - in - ChargeChristopher D. Kidd, A.I.A.
CKA Project Number16008-02
CKA Project ManagerThea M. Watters
1. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES.
2. THESE CONSTRUCTION DRAWINGS AND SPECIFICATIONS ARE A SET AND SHALL BE DISTRIBUTED INTACT. IF SETS ARE DISASSEMBLED TOOBTAIN BIDS FROM SUB-CONTRACTORS, GENERAL CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR SUB-CONTRACTOR COORDINATION.
3. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE NOT INDICATED ON THE DRAWINGS OR CONFLICTS ARE DISCOVERED, THE CONTRACTORSHALL REQUEST CLARIFICATION FROM THE ARCHITECT OR BID THE HIGHEST PRICED ALTERNATIVE.
4. 'PROVIDE' MEANS TO FURNISH AND INSTALL.
5. PRIOR TO THE NEGOTIATED BID, THE CONTRACTOR SHALL VISIT SITE TO VERIFY EXISTING CONDITIONS, PRODUCTS TO BE USED, ANDQUANTITIES REQUIRED. ALL CONTRACTORS ARE REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS FOR ALL TRADES INCLUDINGDIMENSIONS, CONFIGURATION, AND UTILITY SYSTEMS. BIDS SHALL REFLECT ALL CONSTRUCTION NECESSARY TO COMPLETE THE WORKREQUIRED WITH CONSIDERATION GIVEN TO EXISTING CONDITIONS.
6. CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED BY STATE AND LOCAL AUTHORITIES. CONTRACTOR SHALL PICK UP PERMIT AND PAYSUBCONTRACTOR PERMITS. OWNER SHALL PAY FOR GENERAL BUILDING PERMIT.
7. CONTACT STATE DIGGING HOTLINE FROM THE ONE CALL DIRECTORY PRIOR TO PERFORMING ANY UNDERGROUND UTILITY OR EXCAVATIONWORK.
8. GENERAL CONTRACTOR SHALL COORDINATE ALL SITE STAGING, DUMPSTER LOCATION, UTILITIES, EXCAVATION (WHERE APPLICABLE), ETC.WITH THE LANDLORD.
9. MECHANICAL CONTRACTOR SHALL INSTALL COMPLETE HVAC SYSTEM IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERALCODES (INCLUDING THE NFPA 101 LIFE SAFETY CODE, SPECIFICALLY CHAPTER 20) AND BUILDING STANDARDS. THE MECHANICALCONTRACTOR SHALL REFER TO THE STRUCTURAL DRAWINGS FOR NECESSARY STRUCTURAL REINFORCEMENTS WHEN PLACING EQUIPMENTON THE EXISTING STRUCTURE. THE MC SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR THE MECHANICAL PERMIT.
10. PLUMBING CONTRACTOR SHALL INSTALL PLUMBING SYSTEM IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES(INCLUDING THE NFPA 101 LIFE SAFETY CODE, SPECIFICALLY CHAPTER 20) AND BUILDING STANDARDS. THE PC SHALL BE RESPONSIBLE TOOBTAIN AND PAY FOR THE PLUMBING PERMIT.
11. ELECTRICAL CONTRACTOR SHALL INSTALL COMPLETE ELECTRICAL SYSTEM IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, ANDFEDERAL CODES (INCLUDING THE NFPA 101 LIFE SAFETY CODE, SPECIFICALLY CHAPTER 20) AND BUILDING STANDARDS. THE ELECTRICALCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ANY NECESSARY LOW-VOLTAGE PERMITS FOR THE PROJECT AND COORDINATING THELOW VOLTAGE WORK WITH THE OWNER'S VENDOR. THE EC SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR THE ELECTRICAL PERMIT.
12. CONTRACTOR SHALL COORDINATE KEY SCHEDULE WITH THE OWNER PRIOR TO PROJECT SPACE COMPLETION. CLEARLY MARKED KEYSORGANIZED IN THE SPECIFIED KEY CABINET SHALL BE TURNED OVER TO OWNER'S REPRESENTATIVE.
13. FIRE EXTINGUISHERS SHALL BE LOCATED PER LOCAL, STATE AND FEDERAL CODES. KNOX BOX SHALL BE LOCATED PER THE LOCAL FIREMARSHAL.
14. ALL MILLWORK / CABINETRY SHALL BE PROVIDED BY THE OWNER'S MILLWORK VENDOR AND SHALL BE ASSEMBLED AND INSTALLED BY THEGENERAL CONTRACTOR. THE OWNER SHALL PROVIDE THE GENERAL CONTRACTOR WITH THE SHOP DRAWINGS FOR REFERENCE.
15. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COMMISSIONING THE DESIGN-BUILD OF THE NEW FIRE ALARM SYSTEM. LOCALCERTIFIED FIRE ALARM CONTRACTOR (CFAC) SHALL DESIGN FIRE ALARM SYSTEM IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE ANDFEDERAL CODES AND BUILDING STANDARDS INCLUDING THE NFPA 101 LIFE SAFETY CODE (SPECIFICALLY CHAPTER 20). CFAC SHALLWARRANT COMPLETE COMPLIANCE WITH LOCAL FIRE MARSHALL. CFAC IS RESPONSIBLE FOR ALL INCIDENTAL COSTS RELATIVE TO THECOMPLETE INSTALLATION OF THIS SYSTEM INCLUDING SYSTEM DESIGN, ENGINEERING, BATTERY CALCULATIONS, PLAN SUBMITTALS, FEESAND PERMITS. THE CFAC SHALL BE THE ENGINEER OF RECORD FOR THE FIRE ALARM SYSTEM.
16. THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR (FSC) SHALL DESIGN AND INSTALL A COMPLETE NEW, FULLY OPERATIONAL, CODECOMPLIANT (WHICH AT A MINIMUM SHALL INCLUDE NFPA 13 (STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS) AND NFPA 101 LIFESAFETY CODE - SPECIFICALLY CHAPTER 20), APPROVED, HYDRAULICALLY DESIGNED AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT.(THE WATER SERVICE LATERAL, RISER AND MAIN BRANCHES SHALL BE PROVIDED BY LANDLORD) LINE & HEADS SHALL BE NEW AND THE FSCSHALL DESIGN AND PERMIT SYSTEM. THE (FSC) SHALL BE THE ENGINEER OF RECORD, RESPONSIBLE FOR PREPARING AND PROVIDING SIGNEDAND SEALED DRAWINGS AND CALCULATIONS AS REQUIRED BY THE REVIEWING AUTHORITIES AS WELL AS THE CONTRACTOR FOR THE FIRESPRINKLER SYSTEM AND ALL RELATED COMPONENTS. FSC SHALL SUBMIT TO AHJ WITHIN 14 DAYS TO NOT PROLONG PLAN REVIEW ORPERMITTING.
THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING WATER FLOW TESTS, PREPARING SIGNEDAND SEALED PLAN REVIEW, CIVIL AS REQUIRED, AND INSTALLATION DRAWINGS, HYDRAULIC CALCULATIONS, ENGINEERING, ANDCOORDINATING WITH EXISTING CONDITIONS AND WITH OTHER TRADES. FSC SHALL SUBMIT ALL NECESSARY DOCUMENTS TO INSURANCECOMPANY AND OBTAIN APPROVAL AND NECESSARY PERMITS FROM STATE AND LOCAL AUTHORITIES HAVING JURISDICTION.THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR, BEFORE SUBMITTING THE BID, SHALL VISIT THE PROJECT SITE AND FAMILIARIZEHIMSELF WITH ALL EXISTING CONDITIONS. AS A RESULT OF HAVING VISITED THE PREMISES, THE CONTRACTOR SHALL BE RESPONSIBLEFOR THE DESIGN AND INSTALLATION OF THE WORK AS IT RELATES TO SUCH CONDITIONS.THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR (FSC), PRIOR TO SUBMITTING BID, SHALL VERIFY ACCURACY AND COMPLETENESS OFELECTRICAL DRAWINGS AS THEY RELATE TO FIRE SPRINKLER SYSTEM ELECTRICAL REQUIREMENTS. FSC SHALL NOTIFY ELECTRICALENGINEER OF ANY ADDITIONAL ELECTRICAL REQUIREMENTS IN ADVANCE OF BID SO THAT A BID ADDENDA CAN BE ISSUED. SHOULDELECTRICAL CHANGES TO ACCOMMODATE THE FIRE SPRINKLER SYSTEM BE NECESSARY AFTER CONTRACTS HAVE BEEN AWARDED, THEFIRE SPRINKLER DESIGN-BUILD CONTRACTOR SHALL PAY FOR THE ADDITIONAL ELECTRICAL COSTS.THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR SHALL INSTALL ALL PIPING CONCEALED ABOVE CEILINGS OR IN WALLS IN ALL AREASWITH CEILINGS AND IN AREAS CONSIDERED TO BE FINISHED SPACE. SPRINKLER HEADS SHALL BE INSTALLED IN CENTER OF 2' x 2' HALF OF2' x 4' CEILING TILES.THE DESIGN-BUILD FIRE SPRINKLER CONTRACTOR SHALL INSTALL DRY PIPE OR ANTI-FREEZE SYSTEMS IN UNHEATED AREAS (SUCH ASATTIC) SUBJECT TO FREEZING. THE SPRINKLER SYSTEM SHALL BE A COMBINATION WET/DRY SYSTEM IF REQUIRED.THE FSC AND THE GENERAL CONTRACTOR SHALL VERIFY THE HEIGHTS OF THE SPRINKLER SYSTEM COMPONENTS IN RELATION TOSTRUCTURAL ELEMENTS, HVAC, ETC., INCLUDING ALL MAIN LINES AND BRANCH LINES, TO ENSURE THAT THE SPECIFIED CEILING HEIGHTSARE POSSIBLE.
17. (NOT APPLICABLE)
ArchitectChristopher Kidd & Associates, PCN48W16550 Lisbon RoadMenomonee Falls, Wisconsin 53051Phone: 262.901.0505
PME EngineerChristopher Kidd & Associates, PCN48W16550 Lisbon RoadMenomonee Falls, Wisconsin 53051Phone: 262.901.0505
RESPONSIBILITY MATRIXFURNISHED BY INSTALLED BY OWNER'S
VENDOR NOTES
ELECTRONIC SCALE
ITEM
1.
DESCRIPTION
ALL BUILT-IN MILLWORK ITEMS
MUSTEE SINKS LOCATED IN MILLWORK
PT AND SOAP DISPENSERS IN MILLWORK
STL. COUNTER SUPPORT BRACKETS
CHAIR RAIL / WOOD BASE / TRIM
BLOCKING FOR ALL MILLWORK ITEMS
ALL BLOCKING IN WALLS AS REQUIRED
ICE MACHINE AT STAFF LOUNGE
INTERIOR SIGNAGE
EXTERIOR SIGNAGE
BACK-UP POWER GENERATOR
FURNITURE
APPLIANCES
WATER TREATMENT / SDS EQUIPMENT
2.
3.
4.
5.
6.
7.
8.
9.
11.
12.
13.
14.
15.
16.
17.
18.
19.
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
CONTRACTOR
OWNER
OWNER
OWNER
OWNER
OWNER
CONTRACTOR
20.
AUTOMATIC TRANSFER SWITCH
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
OWNER
OWNER
OWNER
SINK FAUCETS / FITTINGS BY G.C.
FINISH BY G.C. (PAINT)
CONTRACTOR
OWNER OWNER MARCOR
R/O AND SDS TUBING / PIPING OWNER OWNER MARCOR
UNDERSLAB SLEEVES FOR SDS TUBING CONTRACTOR CONTRACTOR
21.
VALVE BOXES OWNER CONTRACTOR MARCOR DRAIN CONNECTIONS AND DRAIN PIPING BY G.C.
OTHER PAPER TOWELS BY G.C.
IN REF., WATER BOX BY G.C.
POWER TO BUILDING SIGNS BY G.C.
G.C. COORDINATED
STAPLES
ELECTRICAL FOR WATER TREATMENT CONTRACTOR CONTRACTOR MARCOR COORDINATE W/ OWNER'S VENDOR
ASSEMBLY AND INSTALLATION BY G.C. - SEE SHEET CS1
OWNER CONTRACTOR NARDONE CONDUIT, & CONNECTIONS BY G.C.
SINK AT STAFF LOUNGE10. OWNER CONTRACTOR SINK FAUCETS / FITTINGS BY G.C.
G.C. COORDINATED
TYP ROOM SIGNAGE, TOILET ROOMS
MISKO
MISKO
OCCUPANCY CLASSIFICATION GROUP : - BUSINESS GROUP B (AMBULATORY HEALTH CARE FACILITY)
CONSTRUCTION CLASSIFICATION : - TYPE IIB (EXISTING BUILDING)
FIRE PROTECTION: - FULLY SPRINKLERED (DESIGN/BUILD SYSTEM PER CODE)(SEE GENERAL NOTE #16 THIS SHEET)
- FIRE ALARM SYSTEM (DESIGN/BUILD NEW SYSTEM PER CODE)(SEE GENERAL NOTE #15 THIS SHEET)
- FIRE EXTINGUISHERS LOCATED PER CODE
NUMBER OF STORIES : - 1
ZONING: - CBD - CENTRAL BUSINESS DISTRICT
PARKING : - 9 PARKING STALLS- 2 ACCESSIBLE PARKING STALLS- ADDITIONAL PARKING LOCATED IN PUBLIC LOT ON SOUTHFIELD
ROAD
PROJECT SQUARE FOOTAGEBUSINESS AREA:INCIDENTAL STORAGE / MECH:TOTAL BUILDING SQUARE FOOTAGE:
8,303 G.S.F. 2,357 G.S.F.10,660 G.S.F.
83 OCC.7 OCC.
90 OCC.
PLUMBING FIXTURE CALCULATIONSMINIMUM NUMBER OF PLUMBING FIXTURES (per 2012 MICHIGAN PLUMBING CODE)BUSINESS CLASSIFICATION: TOTAL NUMBER OF TENANT OCCUPANTS: 90(MALE OCCUPANT LOAD: 45 - FEMALE OCCUPANT LOAD: 45)
WATER CLOSETS (MALE): REQUIRED: 2 PROVIDED: 2WATER CLOSETS (FEMALE): REQUIRED: 2 PROVIDED: 2LAVATORIES (MALE): REQUIRED: 2 PROVIDED: 2LAVATORIES (FEMALE): REQUIRED: 2 PROVIDED: 2UNISEX TOILETS: REQUIRED: NONE PROVIDED: 1 UNISEX PATIENT
TOILETOTHER FIXTURES: REQUIRED: 1 SERVICE SINK PROVIDED: 1 SERVICE SINKWATER FOUNTAIN: REQUIRED: 1 PROVIDED: 2 (HIGH/LOW FIXTURE)
PROJECT SCOPE OF WORKTHIS PROJECT INCLUDES THE TENANT IMPROVEMENT OF AN APPROXIMATELY 10,660 S.F, 25 PATIENTSTATION OUT PATIENT CLINIC IN LINCOLN PARK, MICHIGAN WITHIN AN EXISTING BUILDING. THISPROJECT INCLUDES PLUMBING, MECHANICAL, AND ELECTRICAL WORK AS WELL AS NEW FIREPROTECTION SYSTEM AND A NEW FIRE ALARM SYSTEM.
Plan Review Set, IncorporatingAddendum #4, dated March 13,
2017Superceded (December 16, 2016)
TENANT'S REPRESENTATIVE
Bazzi Enterprises, LLCRabih Bazzi, MDrbazzi&gmail.com
OCCUPANT LOAD CALCULATIONS1/100 G.S.F. FOR BUSINESS AREAS USE PER PERSON (8,303 G.S.F.):1/300 G.S.F. FOR STORAGE / MECH AREAS USE PER PERSON (2,357 G.S.F.):TOTAL TENANT OCCUPANT LOAD:
APPLICABLE CODESBUILDING: 2012 MICHIGAN BUILDING CODEPLUMBING: 2012 MICHIGAN PLUMBING CODEMECHANICAL: 2012 MICHIGAN MECHANICAL CODEELECTRICAL: 2014 NATIONAL ELECTRICAL CODEFIRE: 2015 INTERNATIONAL FIRE CODEACCESSIBILITY: 2009 ICC A117.1ENERGY: 2009 MICHIGAN UNIFORM ENERGY CODELIFE SAFETY: 2015 NFPA 101 LIFE SAFETY CODE (CHAPTER 20, AMBULATORY HEALTH CARE FACILITY)
ARCHITECTURALT TITLE SHEETA1.0 ARCHITECTURAL SITE PLAN
LS2.0 LIFE SAFETY PLAN
A2.0 NOTED FLOOR PLANA2.1 DIMENSIONED FLOOR PLANA2.2 ENLARGED PLANSA2.3 FINISH FLOOR PLANA2.5 REFLECTED CEILING PLANA2.6 DOOR SCHEDULEA2.7 HARDWARE SCHEDULEA2.8 FINISH SCHEDULE
A6.0 DETAILSA6.1 DETAILSA6.2 DETAILSA6.3 UL PENETRATION DETAILSA9.0 INTERIOR ELEVATIONSA9.1 INTERIOR ELEVATIONSA9.2 INTERIOR ELEVATIONS
MILLWORKCS1 AMERICAN RENAL MILLWORK
SPECIFICATIONS (FOR REFERENCEONLY)
PLUMBINGP1.0 WATER PLAN AND SCHEDULESP1.1 WATER ISOMETRICP2.0 DRAIN PLAN AND SCHEDULESP2.1 DRAIN ISOMETRIC AND SCHEDULESP3.0 PROCESS PIPING PLANP4.0 PLUMBING DETAILSP4.1 PROCESS DETAILS
MECHANICALM1.0 MECHANICAL SCHEDULESM2.0 MECHANICAL PLANM3.0 MECHANICAL DETAILS
ELECTRICALE1.0 ELECTRICAL RISER AND NOTESE1.1 ELECTRICAL NOTESE1.2 ELECTRICAL PANELSE1.3 ELECTRICAL PANELSE2.0 ELECTRICAL LIGHTING PLANE2.1 ELECTRICAL POWER PLANE2.2 ELECTRICAL COMMUNICATIONS PLANE4.0 ELECTRICAL DETAILSE4.1 LIGHTING DETAILS
WATER TREATMENTVENDOR DRAWINGS(FOR REF. ONLY)ME-1LP-1UL-1TS-1 American Renal Associates, LLC
Project ManagementPhone: 978.778.6463
Contact: Carney McCandless,Project Manager
MISKO
MISKO
MISKO
MISKO
J. GEISLER
C L E O P H U SP K W Y
S O U T H F I E L DR D
LA
FA
YE
TT
EB
LV
D
ARA -LINCOLN
PARK
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
T
TMW
JLR
TITLESHEET
A1
A1
01-2
4-17
AD
DE
ND
UM
#1M
MW
A2
A2
A2
02-2
8-17
AD
DE
ND
UM
#2M
MW
A2
A2
A2
A2
A2
A2
A2
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
Prepared by:Engineer
Royal Del Glenn, PEMichigan License # 6201049671Expires: October 31, 2017
Date of Review:
Seal:
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
A3
A3
03-0
3-17
AD
DE
ND
UM
#3JL
R
A3
A4
A4
03-1
3-17
AD
DE
ND
UM
#3JL
R
2' x 4' FLUORESCENTLIGHT FIXTURES
1' X 4' STANDARDFLUORESCENTSTRIP W/ DBL. LAMP
RECESSEDLIGHT FIXTURES
GWB SOFFIT
ACT CEILING
SLOTDIFFUSER
EGRESS LIGHT
EMERGENCYBACKUP LIGHT
EXIT SIGN
SMOKE DETECTOR
GWB - 5/8" GYPSUM WALL BOARD
O.T.S. - OPEN TO STRUCTURE
N.I.C. - NOT IN CONTRACT
B.O.T. - BOTTOM OF TRUSS
D.F.P. - DRY FOG PAINT
ACCESS PANEL, SEE SPEC09260
2' x 4' INDIRECTFLUORESCENT LIGHTFIXTURES
S
H HEAT DETECTOR
HVAC GRILLES
SUSPENDED 1' X 4'FLUORESCENT LIGHT
WALL MOUNTEDFLUORESCENT LIGHT
EXIT
EXTERIOREGRESS LIGHT
CEILING GENERAL NOTES
CEILING LEGEND(NOT ALL SYMBOLS NECESSARILY USED)
A ACCENT PAINTCOLOR
VACT CEILING(WASHABLE VINYLCOATED TILES)
SMOKE PARTITIONCARBON MONOXIDEDETECTOR
1. CEILING HVAC CONTRACTOR SHALL LOCATE ALL CEILING DIFFUSERS ANDCOORDINATE WITH ELECTRICAL CONTRACTOR AS REQUIRED. ANYDIFFUSERS LOCATED IN DRYWALL CEILINGS SHALL BE PAINTED TO MATCHTHE CEILING COLOR IF AN ACCENT COLOR IS SPECIFIED.
2. SUSPENDED CEILING SYSTEM SHALL BE 2'x2'x5/8" OR 2'x4'x5/8" LAY-INACOUSTICAL TILE STANDARD GRID AS SHOWN (SEE SPECIFICATIONS FORVARIOUS TYPES OF TILES USED).
3. REFLECTED CEILING PLAN IS SHOWN FOR SUSPENDED CEILING SYSTEMINSTALLATION ONLY. ELECTRICAL CONTRACTOR SHALL INSTALL ALLELECTRICAL ITEMS PER ELECTRICAL DRAWINGS.
4. CONTRACTOR SHALL COORDINATE REFLECTED CEILING PLAN WITHAPPROPRIATE TRADES INCLUDING MECHANICAL, ELECTRICAL, PLUMBING,FIRE PROTECTION, ETC.
5. CONTRACTOR SHALL PROVIDE SOUND BATT INSULATION ABOVE CEILINGEXTENDING OUT 4'-0" EACH SIDE OF ALL TYPE 'B' WALLS. PROVIDE SOUNDBATT INSULATION ABOVE THE ENTIRE CEILING IN THE FOLLOWING ROOMS:TOILETS, OFFICES, RECEPTION, STAFF LOUNGE, CONFERENCE, ANDPD/EXAM ROOM.
6. FIRE PROTECTION CONTRACTOR SHALL DESIGN FIRE PROTECTION SYSTEMTO MEET ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES (INCLUDINGNFPA 13 AND CHAPTER 20 OF THE NFPA 101). SPRINKLER HEADS SHALL BECENTERED IN TILES. COORDINATE WITH LANDLORD.
7. CONTRACTOR SHALL VERIFY IN FIELD IF DESIGNATED CEILING HEIGHTS INROOMS ARE POSSIBLE. IF NOT, NOTIFY ARCHITECT AND PROJECTMANAGER FOR APPROVAL BEFORE BIDDING. IF ARCHITECT AND PROJECTMANAGER ARE NOT NOTIFIED, IT IS ASSUMED THAT MEANS OF PROVIDINGTHE SPECIFIED CEILING HEIGHTS ARE INCLUDED IN THE BID. (i.e.INCLUDING RELOCATION OF SPRINKLER MAIN PIPING.)
8. AT SUSPENDED CLOUD SOFFIT AREAS, THE CONTRACTOR SHALL COORDINATE ALL TRADES TO ENSURE THAT WIRES,
CONDUITS, DUCTWORK, ETC. ARE NOT READILY VISIBLE ABOVE THE SOFFITAREA. (i.e. CONDUITS TO LIGHTING FIXTURES SHALL BE ROUTED ALONGTHE TOP SURFACE OF THE SOFFIT AND EXIT THROUGH THE CEILING ABOVEIN ONE CENTRAL POINT THAT IS NOT VISIBLE FROM FLOOR LEVEL. PAINTALL WIRES, DUCTWORK, ETC. THAT ARE EXPOSED WHITE.
PENDANT LIGHTFIXTURES
1 HOUR FIREBARRIER
1 HR FIRE/SMOKEBARRIER
AP
EXITEXIT
0 2'-0" 4'-0" 8'-0"
SCALE: 3/16" = 1'-0"
SMALL PENDANTLIGHTS (TYP)
OTSDFP
BULKHEADAT 8'-8" A.F.F.
TYP6
A6.2
WATERTREATMENT
149
STORAGE148
INFECTIOUSWASTE
111
DATAROOM
140
RISERROOM
151
CORRIDOR110
STAFFLOUNGE
147
DOCTOR/EXAM
108
DIETITIANOFFICE
109
COATS103
WAITINGROOM
101
CORRIDOR106
STAFFLOCKERS
144
CONFERENCE143
REPAIR/FTM141
MEN'SPUBLICTOILET
105
NOURISHMENTSTATION
102
VESTIBULE100
MEDPREP120
CLINICMANAGER
142
SCALE/H.C.HANDWASH
SINK126
WHEELCHAIRS/EQUIP.
STORAGE131
CLEANBLEACH
SINK134
NURSESTATION
124
HANDWASHSINK125
TREATMENTROOM
129
PATIENTTOILET
114
LABPREP117
JANITOR112
SOILEDHOLDING
113
MEN'SSTAFFTOILET
146
WOMEN'SSTAFFTOILET
145
DIRTYBLEACH
SINK133
HANDWASHSINK123
EQUIP.STORAGE
121
PRIVATEDIALYSIS
130
ELECTRICALALCOVE
150
EQUIP.STORAGE
116
NURSESTATION
119
CLEANBLEACH
SINK135
DIRTYBLEACH
SINK136
HANDWASHSINK118
WHEELCHAIRS/EQUIP.
STORAGE138
HANDWASHSINK132
HANDWASHSINK137
DIRTYBLEACH
SINK122
WOMEN'SPUBLICTOILET
104
CORRIDOR139
8'-0"DAPW
8'-0"DAPW
8'-0"DAPW
8'-0"DAPW
8'-0"DAPW
8'-0"DAPW
OTSDFP
OTSDFP
OTSDFP
RECEPTION127
MEDRECORDS
128
SOCIALWORKEROFFICE
107
9'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
9'-0"VACT
8'-0"DAPW
8'-0"DAPW
11'-0"ACT-1
11'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
9'-0"ACT-1
11'-0"ACT-2
11'-0"ACT-1
11'-0"ACT-1
11'-0"ACT-1
10'-0"GWB
10'-0"GWB
10'-0"GWB
11'-0"ACT-2
11'-0"ACT-1
11'-0"ACT-1
11'-0"ACT-1
10'-0"GWB
10'-0"ACT-2
10'-0"ACT-2
11'-0"ACT-1/2
TYP5
A6.2
WORKCOUNTER/
CLEAN SUPPLY115
10'-9 1/2"26'-0"3'-7 1/2"
3'-2
"10
'-0"
3'-2
"
15'-2 1/2" 48'-0" 16'-3 1/2"
9'-8
"10
'-0"
22'-0
"10
'-0"
1'-0
"
48'-0" 15'-2 1/2"10'-2 1/2"
10'-0"GWB
10'-0"ACT-2
10'-0"ACT-2
8A6.2
LIGHT COVE
7A6.2
8A6.2
TYP
TYP
FINISH ALL VISIBLEAREAS OF SOFFIT
FINISH ALL VISIBLEAREAS OF SOFFIT
EXISTALUM
EXISTING ALUMINUMSOFFIT AND LIGHTING
BY LANDLORD
EXISTING ROOF STRUCTURE ABOVE
AP AP
AP
AP
AP
AP
AP
LED STRIP LIGHTING ONCLOUD TRIM. SEE DETAIL #6ON SHEET A6.2
OTSDFP
METAL LADDER TOROOF, BY LANDLORD
MC SHALL ROUTECONDENSATE FROM FC-1TO HUB DRAIN IN ROOM
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
A2.5
TMW
JLR
REFLECTEDCEILING PLAN
A2
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
W
A1
A4
03-1
3-20
17A
DD
EN
DU
M#4
MM
W
GENERAL NOTES - DOORS AND WINDOWS1. FIELD VERIFY ALL DIMENSIONS PRIOR TO SHOP DRAWINGS SUBMITTAL AND
SUBSEQUENT FABRICATION OF ALL DOORS AND WINDOWS
2. ALL INTERIOR DOORS ARE TO HAVE A GRADE 'A' FACE OVER A BONDED 7-PLY COREWITH A WHITE BIRCH VENEER FACTORY FINISH WITH A STAIN TO BE SELECTEDFROM THE MANUFACTURER'S STANDARD COLOR SELECTIONS. SAMPLES FORAPPROVAL MUST BE SUBMITTED TO ARCHITECT AND SUBSEQUENTLY APPROVED BYTHE OWNER.
3. ALL VISION PANELS IN FIRE RATED DOORS TO HAVE TECHNICAL GLASS PRODUCT'SFIRELITE NT GLAZING (NO WIRE GLASS IS PERMITTED).
4. ALL DOOR HARDWARE (STYLE AND FINISH) ON NEW AND EXISTING EXTERIOR DOORSTO MATCH EXISTING BUILDING STANDARD (FIELD VERIFY). GENERAL CONTRACTORSHALL FIELD VERIFY EXISTING DOORS TO REMAIN AND COORDINATE HARDWAREREPLACEMENT AS NECESSARY TO MEET FUNCTION OF SPECIFIED HARDWARE SETLISTED IN SCHEDULE.
5. INTERIOR WINDOW/LITE PRIVACY FILM SHALL BE 3M FASARA DECORATIVE WINDOWFILM. PATTERN SHALL BE SELECTED BY ARCHITECT/OWNER FROMMANUFACTURER'S STANDARD SELECTIONS. EXTERIOR REFLECTIVE PRIVACY FILMSHALL BE DELTA DUAL REFLECTIVE 10% ONE WAY FILM.
6. ALL INTERIOR HOLLOW METAL DOOR AND WINDOW FRAMES SHALL BE PAINTED THEFIELD WALL PAINT COLOR. ALL EXTERIOR DOOR AND WINDOW FRAMES SHALLMATCH THE EXISTING BUILDING STANDARD FINISH.
7. ALL INTERIOR DOOR FRAMES SHALL BE CAULKED TO THE FLOOR AT HARD SURFACEFLOORING AREAS.
8. PROVIDE 30" HIGH X 2" LESS WIDTH OF DOOR STAINLESS STEEL KICK PLATES ONALL INTERIOR DOORS EACH SIDE.
9. THE GENERAL CONTRACTOR AND DOOR HARDWARE SUPPLIER SHALL REVIEW THE'REMARKS' COLUMN OF THE SCHEDULE AND COORDINATE AS NECESSARY AS SOMEHARDWARE COMPONENTS NOT STANDARD TO A SPECIFIC HARDWARE SET MAY BEINDICATED.
10. NO DOORS SHALL BE ALLOWED TO HAVE THUMB TURN LOCKS, IF EXISTING ONEXTERIOR DOORS, THE HARDWARE MUST BE REPLACED BY THE CONTRACTOR.
11. CONTRACTOR SHALL PROVIDE KNOX BOX AS REQUIRED BY LOCAL FIREMARSHAL.SEE SPECICIATION SECTION 16400.
12. SEE SHEET A2.7 FOR KEYING SCHEDULE. GENERAL CONTRACTOR SHALLCOORDINATE KEYING BETWEEN OWNER AND DOOR HARDWARE SUPPLIER.
NOTE: SEE RECEPTION WINDOW ELEVATION #1 ONSHEET A9.0 AND RECEPTION WINDOW SECTIONS ONSHEET A6.1 FOR SLIDING RECEPTION WINDOW DETAILS
VERIFY DIMENSIONSOF WINDOWS FORPRIVACY FILM
TYPICAL DOOR APPROACH DETAILSSCALE: 1/4" = 1'-0"
12" MIN.
48"M
IN.
PUSH SIDE
PUSH SIDE
60"M
IN.
18"MIN.
PULL SIDE
PULL SIDE
24"MIN.
PUSH SIDE
24" MIN
PULL SIDE
36"MIN.
60"M
IN.
22" MIN.
* 12" MIN. CLEARANCEREQUIRED ONLY IF BOTHCLOSER AND LATCH AREPROVIDED.
** 54" MIN. CLEARANCEREQUIRED WHENCLOSER IS PROVIDED.
*** 48" MIN. IF BOTH CLOSERAND LATCH AREPROVIDED.
**** 48" MIN. IF CLOSER ISPROVIDED.
PULL SIDE
42" MIN.
54"M
IN.
12"MIN.
*
*
48"M
IN.
**
42"M
IN.
***
42"M
IN.
****
SCALE: 1/4" = 1'-0"
INTERIOR WINDOW FRAME TYPES
3'-0
"6"
V.I.F. 6"6"
W2
4'-0"
4'-7"
2" 5"
HOLLOW METAL FRAME -PAINT TO MATCH DOOR
FRAME COLOR
W4
1/4" TEMP.GLAZING(TYP.)
2'-0"
3'-6
"3'
-4"
2'-4"
2" 2"
HOLLOW METAL FRAME -PAINT TO MATCH DOOR
FRAME COLOR
TYPE BTYPE A
S.C. WOOD DOORW/ VISION PANEL
FRAME TYPES
TYPE 1
HOLLOW METAL ORALUM. FRAME
VARIES
2"
DETAIL J-1
2" ATDOORS (TYP)
1/4" TEMPEREDGLAZING
FINISHFLOOR
2'-6
"1'
-0"
6"10"
SE
ES
CH
ED
ULE
2"
2" SEESCHED.
2"
SCALE: 1/4" = 1'-0"
2"6'
-0"
8'-6
"
2"10
"
3'-6" 3'-2"
12'-11"
2" 2"
2"1'
-2"
2"OPEN TRANSOM(NO GLAZING.SEE DETAIL #15ON SHEET A6.1)(TYP.)
1/4" TEMPEREDGLAZING (TYP.)
TYPE 3
ALUMINUM FRAME -(CLEAR ANODIZEDALUMINUM FINISH),
OPEN TRANSOM AREA
FRAME
DOOR SCHEDULE
MAT'LTYPEWIDTHSIZEHGT THICK
DOORMAT'LLABEL
FRAMETYPE
HARDWARESET
HEAD &JAMB
GLASSPANEL REMARKS AND HARDWARE NOTES
LOCATION
DOOR TYPES
12"
SCALE: 1/4" = 1'-0"
OPEN TRANSOM(NO GLAZING.SEE DETAIL #15ON SHEET A6.1)(TYP.)
4'-0"4'-0" 5"2"2"
10"
6'-0
"2"
2"1'
-2"
2"
8'-6
"
TYPE C
S.C. WOOD DOORW/ VISION PANEL,
PROVIDE FROSTEDPRIVACY FILM ON
GLAZING
1/4" TEMPEREDGLAZING
TYPE E
INTERIORALUMINUM DOOR(CLEAR ANODIZEDALUMINUM FINISH)
S.C. WOOD DOOR
3'-2" 2"
W1
ALUMINUM FRAME -(CLEAR ANODIZED
ALUMINUM FINISH), OPENTRANSOM AREA
8'-9"
1/4" TEMP.GLAZING (TYP.)
HEAD SIMILAR
FINISHFLOOR
LATCH SIDE
HINGESIDE
7-B
8
5-A
CIPHER LOCK ON TREATEMENT ROOM SIDE, ALWAYS OPERABLE FROM CORRIDOR 139 SIDE FOR EGRESS, CONNECT TO FIRE ALARM FOR EGRESS,SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGS
16-A CIPHER LOCK, PANIC BAR EXIT DEVICE, STAFF ENTRANCE
7-A -
18-B
5-B
10-A CIPHER LOCK, UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, TACTILE WARNING INSERT ON LEVER HANDLE
PROVIDE COAT HOOK
18-A TACTILE WARNING INSERT ON LEVER HANDLE
9 CIPHER LOCK, UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS
3-A CIPHER LOCK ON WAITING ROOM SIDE, ALWAYS OPERABLE FROM TREATMENT ROOM SIDE FOR EGRESS, POWER OPERATOR, ELECTRIC STRIKE, CONNECTTO FIRE ALARM FOR EGRESS, SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGS, PROVIDE FROSTED PRIVACY FILM ON GAZING
13 OPEN TRANSOM AREA FOR SOUND TRANSMITTANCE, NO LOCKING HARDWARE , PUSH/PULL BY DOOR SUPPLIER
UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, PROVIDE COAT HOOK
CIPHER LOCK ON CORRIDOR SIDE, ALWAYS OPERABLE FROM STORAGE SIDE, TACTILE WARNING INSERT ON LEVER HANDLE
17-A DELIVERY ENTRANCE
UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, PROVIDE COAT HOOK
UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, PROVIDE COAT HOOK
CIPHER LOCK, PROVIDE COAT HOOK, TACTILE WARNING INSERT ON LEVER HANDLE
UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, TACTILE WARNING INSERT ON LEVER HANDLE
100A VESTIBULE TO EXTERIOR
100B
104
105
106A
106B
107
108
109
110
111
112
113
114
127
128
129A
129C
129B
130
139
140
141
143
145
146
VESTIBULE TO WAITING ROOM
142
147
WOMEN'S PUBLIC TOILET
MEN'S PUBLIC TOILET
CORRIDOR TO WAITING ROOM
CORRIDOR 106 TO CORRIDOR 110
SOCIAL WORKER OFFICE
DOCTOR / EXAM
DIETITIAN OFFICE
CORRIDOR TO EXTERIOR
INFECTIOUS WASTE
JANITOR
SOILED HOLDING
PATIENT TOILET
RECEPTION
MED RECORDS
TREATMENT ROOM TO WAITING ROOM
TREATMENT ROOM TO CORRIDOR 110
TREATMENT ROOM TO CORRIDOR 139
PRIVATE DIALYSIS
CORRIDOR 139 TO CORRIDOR 110
DATA ROOM
REAPIR / FTM
CLINIC MANAGER
CONFERENCE
WOMEN'S STAFF TOILET
MEN'S STAFF TOILET
STAFF LOUNGE
148A
148B
149
150
151
STORAGE TO CORRIDOR
STORAGE TO EXTERIOR
WATER TREATMENT
NOT USED
RISER ROOM
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" B -
3'-0" 7'-0" 1-3/4" B 45 MIN.
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A 45 MIN.
3'-0" 7'-0" 1-3/4" A 45 MIN.
3'-0" 7'-0" 1-3/4" A SMOKE
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" B -
3'-0" 7'-0" 1-3/4" A SMOKE
3'-6" 7'-0" 1-3/4"
3'-6" 7'-0" 1-3/4"
3'-0" 7'-0" 1-3/4"
C -
B 45 MIN.
B 45 MIN.
3'-6" 7'-0" 1-3/4" E -
3'-0" 7'-0" 1-3/4" B -
3'-0" 7'-0" 1-3/4" A 45 MIN.
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" A -
3'-0" 7'-0" 1-3/4" B -
SMOKE
-
3'-6" 7'-0" 1-3/4" B
-
-
VP
VP
-
-
-
-
-
-
-
VP
-
HALF
VP
VP
FULL
VP
-
-
-
-
-
-
VP
VP
-
J-4ALUM ALUM3
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1WD HM1
J-1- --
5" 2'-0"
W3
4'-0"
2"3'
-4"
2"3'
-6"
4'-7"
7'-2
"
5" 2"
HOLLOW METAL FRAME -PAINT TO MATCH DOOR
FRAME COLOR
3 /16" FIRERATEDGLASS,FIRE LITENT, SEESPEC08800
2"3'
-4"
2"3'
-6"
7'-2
"
AUTOMATIC SLIDING DOOR, SENSOR REMOTE RELEASES, TRANSOM. SEE WIRING DIAGRAM ON SHEET A2.7, COORDINATE WIRING WITHINSTALLATION OF LANDLORD PROVIDED DOORPOWER OPERATOR, ELECTRIC STRIKE, PANIC BAR EXIT DEVICE, SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWING, COORDINATE WIRINGWITH INSTALLATION OF LANDLORD PROVIDED DOORUNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, PROVIDE COAT HOOK
UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, PROVIDE COAT HOOK
CIPHER LOCK ON WAITING ROOM SIDE, ALWAYS OPERABLE FROM CORRIDOR SIDE FOR EGRESS, CONNECT TO FIRE ALARM FOR EGRESS,SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGSCIPHER LOCK ON CORRIDOR 106 SIDE, ALWAYS OPERABLE FROM CORRIDOR 110 SIDE FOR EGRESS, CONNECT TO FIRE ALARM FOR EGRESS,SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGS
PROVIDE COAT HOOK
PROVIDE COAT HOOK
PROVIDE COAT HOOK
PROVIDE COAT HOOK
CIPHER LOCK, UNDERCUT DOOR 3/4" - SEE MECHANICAL DRAWINGS, TACTILE WARNING INSERT ON LEVER HANDLE
CIPHER LOCK ON CORRIDOR 110 SIDE, ALWAYS OPERABLE FROM CORRIDOR 139 SIDE FOR EGRESS, CONNECT TO FIRE ALARM FOR EGRESS,SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGS
-
SLIDING GATE, SEE SPECIFICATION SECTION 10605 AND DETAIL #9 ON SHEET A9.1, CIPHER LOCK WITH LEVER HANDLE OUTSIDE,LEVER HANDLE INSIDE (NO THUMB TURN LOCK)
-
1-B
2-B
4-B
4-B
4-A
4-A
4-A
12
12
12
7-B
5-A
5-A
5-A
7-B
15
19-A
6
4'-0" 7'-0" - -
CIPHER LOCK ON CORRIDOR 110 SIDE, ALWAYS OPERABLE FROM TREATMENT ROOM SIDE FOR EGRESS, CONNECT TO FIRE ALARM FOR EGRESS,SEE WIRING SCHEMATIC ON SHEET A2.7 AND ELECTRICAL DRAWINGS
DETAIL J-4
VARIES
OPEN TRANSOM(NO GLAZING.SEE DETAIL #15ON SHEET A6.1)
HEAD SIMILAR(MATCH EXISTING
BUILDINGSTANDARD
CONSTRUCTION)
FRAME DETAILS
FINISHFLOOR
2"2"
7'-2
"
EX
EX
EX
EX EXISTEXIST EXIST EXIST EXIST EXIST EXISTEXIST EXISTEXIST
EXISTEXIST EXIST EXIST EXIST EXIST EXISTEXIST EXISTEXIST
EXISTEXIST EXIST EXIST EXIST EXIST EXISTEXIST EXISTEXIST
EXISTEXIST EXIST EXIST EXIST EXIST EXISTEXIST EXISTEXIST
EXISTEXIST EXIST EXIST EXIST EXIST EXISTEXIST EXISTEXIST 10-B
SCALE: 3" = 1'-0"INTERIOR DOOR DETAILS1
METAL STUD RUNNER
GYPSUM BOARD AS SPECIFIED
DOUBLE METAL STUDS
JAMB ANCHOR
JAMB
HEAD
SEE FLOOR PLAN ANDPARTITION TYPE DETAILSFOR PARTITION TYPE ANDTHICKNESS
METAL STUD SIZEVARIES - 3 5/8" (TYPICAL)
GYPSUM BOARD ASSPECIFIED
METAL DOOR FRAME FIRERATED WHERE REQUIRED
2"
VA
RIE
S
NOTE: CAULK ALL DOORFRAMES TO FLOOR IN ALLHARD SURFACE FLOORINGAREAS THROUGHOUT THEFACILITY WITH CLEARSILICONE OR CAULK TOMATCH DOOR FRAMECOLOR.
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
A2.6
TMW
JLR
DOORSCHEDULE
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
A2
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
W
A1
A4
03-1
3-20
17A
DD
EN
DU
M#4
MM
W
44 1/2" A.F.F.
1'-0"
10"
51/
2"
23/
4"
58 1/2" A.F.F.
3/4" CLEATS ATENDS ANDBETWEEN RACKS1" RADIUS ON
BOTTOM EDGEOF FACE
1-1/4" DIA. CHROMEDOWEL
3MM EDGEBAND
FACE OF WALL, FINISH ASSCHEDULED
SCREW CLEAT ENDS ANDBACK INTO SOLID FRT WOODBLOCKING BEHIND WALL
3/4" CLEAT ATBACK
3/4" SHELF
SCALE: 1 1/2" = 1'-0"COAT SHELF DETAIL8
48" A.F.F.(TOP OF SHELF)
NOTE:COAT SHELF SHALL BEFURNISHED BY OWNER'SMILLWORK VENDOR ANDINSTALLED BYCONTRACTOR
3'-8
"3'
-6"A
.F.F
.
CLINIC MANAGER SIDE TREATMENT ROOM SIDEBASE AS SCHEDULED
7'-2" (V.I.F.)
HOLLOW METAL FRAME- PAINT TO MATCHEXTERIOR ALUMINUMSTOREFRONT FRAMESYSTEM (BLACK OR DARKBRONZE, V.I.F.)
BASE AS SCHEDULED
5"
FRAME ANCHORS
HOLLOW METAL FRAME WITH 3ANCHORS MINIMUM PER JAMB
3 /16" FIRE RATED GLASS,FIRE LITE NT, SEE SPEC08800
3/4" X 3/4" APPLIED METAL STOP(PAINTED TO MATCH FRAME)
ALIGN TO DOOR HEAD HEIGHT
PROVIDE DOUBLE STUDSTYPICAL AT ALL HEADS
TYPICAL SECTION AT
SCALE: 1 1/2" = 1'-0"CLINIC MANAGER WINDOW14
PROVIDE BLINDS CLINICMANAGER SIDE
SEAL TOP OF MILLWORKTO WALL WITH CLEARSILICONE CAULK
SCALE: 1 1/2" = 1'-0"PRIVATE DIALYSIS WINDOWS15
TYPICAL SECTION AT
GYPSUM BOARD RETURN
2x4 FRT WOOD BLOCKING(TYP)
SEE SHEET A6.0 FORPARTITION TYPE
SEALANT AND BACKERROD EACH SIDE
7'-2
"
PRIVATE DIALYSIS SIDEDIALYSIS ROOM SIDE
8'-6"
ALIGN TO DOOR HEAD
ALUMINUM WINDOWFRAME - FACTORYFINISHED CLEARANODIZED ALUMINUM
4 7/8"
PROVIDE 1/4" CLEARTEMPERED GLAZING
10"A
.F.F
.
NO GLAZING IN TRANSOMAREA. SMOOTH FINISH, NORECESS FOR GLAZING.
2x4 FRT WOOD BLOCKING(TYP)
PROVIDE BLINDS ONOUTSIDE OF PRIVATEDIALYSIS
BASE AS SCHEDULED,EACH SIDE
SCALE: 1 1/2" = 1'-0"COFFEE STATION COUNTER4
KNEE SPACE
PLASTIC LAMINATEWORK SURFACE WITH3MM SELF EDGE BANDTO MATCH
FRT 2 X 4 WOODBLOCKING
PAINTED CHAIR RAIL, SEEDETAIL #5 ON THIS SHEET
PLASTIC LAMINATE TRANSACTIONCOUNTER/SILL WITH 3MM SELFEDGE BAND TO MATCH
NOTE:RECEPTION DESK ANDCOFFEE STATION COUNTERSHALL BE FURNISHED BYOWNER'S MILLWORKVENDOR AND INSTALLED BYCONTRACTOR
1'-3"
COFFEE STATION OPENING IS OPEN TOWAITING ROOM, INSTALL LOCKABLEHINGED PANEL PROVIDED BY OWNER'SMILLWORK VENDOR
ENSURE DOOR ISHELD UP FROMCOUNTER SURFACETO CLEAR THECOFFEE MAKERCORD
FRT 2 X 4 WOODBLOCKING
SCALE: 1 1/2" = 1'-0"SECTION AT TRANSACTION COUNTER2
KNEE SPACE
PLASTIC LAMINATEWORK SURFACE WITH3MM SELF EDGE BANDTO MATCH
FRT 2 X 4 WOODBLOCKING
PAINTED CHAIR RAIL, SEEDETAIL #5 ON THIS SHEET
PLASTIC LAMINATE TRANSACTIONCOUNTER/SILL WITH 3MM SELF EDGEBAND TO MATCH
LOCKABLE SLIDING TEMPERED GLASSBI-PASS WINDOW. SEE SPEC SECTION08800 FOR MORE INFORMATION
SET ALUMINUM DOUBLE GLAZING TRACKINTO PLASTIC LAMINATE SILL AT BOTTOMAND MECHANICALLY FASTEN TO HOLLOWMETAL WINDOW FRAME AT TOP. TOP OFALUMINUM GLAZING TRACK FLUSH WITHPLASTIC LAMINATE COUNTER
NOTE:RECEPTION DESK ANDTRANSACTION COUNTERSHALL BE FURNISHED BYOWNER'S MILLWORKVENDOR AND INSTALLEDBY CONTRACTOR
1'-3"
SECTION AT
SINGLE GANG BOX BY E.C.(FOR COAX CABLE)
SINGLE GANG BOX (110VRECEPTACLE) BY E.C.
2x12 FRT WOOD BLOCKING, GC SHALLVERIFY BRACKET WITHCOMMUNICATIONS SYSTEMS VENDORFOR PROPER BLOCKING SIZE
ANGLE BY SIMPSON STRONGTIE (TYPICAL AT EACH CORNER)
3/4" ELEC. CONDUIT TO 6" ABOVEFINISHED CEILING BY E.C.
2 x WOOD STUDS EACH SIDE OF(FULL DEPTH) WALL FRAMINGEXTEND TO STRUCTURE ABOVE1'-4"
60"A
.F.F
.@E
XA
M,
84"A
.F.F
.@C
ON
FER
EN
CE
/STA
FFLO
UN
GE
,72
"A.F
.F.@
WA
ITIN
G(V
ER
IFY
DE
SIR
ED
MO
UN
TIN
GH
EIG
HT
OF
TVW
ITH
OW
NE
R)
WALL MOUNTED TELEVISION ANDBRACKET (N.I.C.) BY OWNER'SCOMMUNICATIONS SYSTEM VENDOR.
C L
C L1'
-0"
SCALE: 3/4" = 1'-0"WALL MOUNTED TV DETAIL12
2'-8
"FR
OM
F.F.
TOTO
PO
FR
AIL2" X 2" PLASTIC CORNER
GUARD. INSTALLED LENGTHIS FROM TOP OF BASE TOUNDERSIDE OF CORNERBLOCK. INSTALL AT ALLOUTSIDE CORNERS OFWAITING ROOM DIRECTLYOVER WALL COVERING.
BASE AS SCHEDULED
ACCENT PAINT BELOW ATCONFERENCE, INPRO WALLPROTECTION BELOW ATWAITING ROOM AND LOUNGE
PAINTED CHAIR RAIL. REFERTO DETAIL #5 ON THIS SHEET,SEAL TOP OF CHAIR RAIL TOWALL WITH CLEAR SILICONECAULK THROUGHOUT, MITERCORNERS AS APPLICABLE
SCALE: 3/4" = 1'-0"CHAIR RAIL DETAIL7
WALL COVERINGABOVE IN WAITINGROOM WHEREINDICATED
SCALE: 3/4" = 1'-0"SECTION AT COFFEE STATION WINDOW3
KNEE SPACE
4'-0
"C
LEA
RO
PE
NIN
G3'
-0"
MA
X.
REFER TO DETAIL#4 ON THIS SHEET
PLASTIC LAMINATE WORKSURFACE WITH 3MM SELF EDGEBAND TO MATCH SCRIBE ANDSEAL TO WALL WITH SILICONE
2'-6
"M
AX
.
HEADER AS REQUIRED
2 X 4 FRT WOOD BLOCKING
PAINTED CHAIR RAIL, SEEDETAIL #5 ON THIS SHEET
PLASTIC LAMINATE ON PLYWOODWALL CAP/SILL WITH 3MM SELFEDGE BAND TO MATCH
7'-0
"
GYPSUM WALLBOARD - SEEFLOOR PLAN AND SHEETA6.0 FOR PARTITION TYPES
NOTE:RECEPTION DESK ANDCOFFEE STATIONCOUNTER SHALL BEFURNISHED BY OWNER'SMILLWORK VENDOR ANDINSTALLED BYCONTRACTOR
PAINTED WOOD TRIM
1'-3"
METAL CANTILEVER BRACKET,AS REQUIRED FORWORKSURFACE SUPPORT
COFFEE STATION OPENING, NOGLAZING, INSTALL LOCKABLE HINGEDPANEL, WOOD CASING PROVIDED BYOWNER'S MILLWORK VENDOR (I.B.C.)
2 X 4 WOOD BLOCKING
BASE AS SCHEDULED
SCALE: 3/4" = 1'-0"SECTION AT RECEPTION WINDOW1
KNEE SPACE
3'-6
"C
LEA
RO
PE
NIN
G3'
-6"
MA
X.
REFER TODETAIL #2 ONTHIS SHEET
2'-6
"
LOCKABLE SLIDINGGLASS BI-PASS WINDOW
TOP OF ALUM. GLAZING TRACKFLUSH WITH PLASTIC LAMINATETRANSACTION COUNTER
BASE AS SCHEDULED
2 X 4 WOOD BLOCKING
HEADER AS REQUIRED
2 X 4 FRT WOOD BLOCKING
PAINTED CHAIR RAIL,SEE DETAIL #5 ONTHIS SHEET
PLASTIC LAMINATE ONPLYWOOD WALL CAP/SILLWITH 3MM SELF EDGEBAND TO MATCH
7'-0
"
GYPSUM WALLBOARD - SEEFLOOR PLAN AND SHEETA6.0 FOR PARTITION TYPES
NOTE:RECEPTION DESKAND TRANSACTIONCOUNTER SHALLBE FURNISHED BYOWNER'SMILLWORKVENDOR ANDINSTALLED BYCONTRACTOR
WRITING SURFACESHELF BY OWNER'SMILLWORK VENDOR- INSTALLED BYCONTRACTOR
2'-1
0"
PAINTED WOOD TRIM
1'-3"
METAL CANTILEVERBRACKET, AS REQUIREDFOR WORKSURFACESUPPORT
PLASTIC LAMINATE WORKSURFACE WITH 3MM SELFEDGE BAND TO MATCHSCRIBE AND SEAL TOWALL WITH SILICONE
SCALE: 1" = 1'-0"COUNTER MOUNT TV (N.I.C.) DETAIL13
1'-0"
DIALYSIS CHASE CABINET ANDCOUNTERTOP PROVIDED BYOWNER'S MILLWORK VENDOR,INSTALLED BY CONTRACTOR
FACE OF GYPSUM BD. ATWALL BEYOND - SEE FLOORPLAN, SHEET A2.0 AND WALLTYPES SHEET A6.0 FOR WALLCONSTRUCTION TYPES
PLASTIC LAMINATE BACKSPLASH,PROVIDED BY OWNER'S MILLWORKVENDOR, INSTALLED BY CONTRACTOR
2"
5/8" DENS ARMOR PLUS TO48" A.F.F. OR TO UNDERSIDEOF WALL CAP BEHINDDIALYSIS CABINETS
CONTINUOUS FRT 2XBLOCKING @ TOP ANDBOTTOM OF WALLMOUNTED CABINET
TV SUPPORT ARM (N.I.C.)
TABLE MOUNT FOR TVSUPPORT ARM W/ BASEPLATE BOLTED THROUGHMDF AND PLYWOOD LAYERSOF COUNTERTOP (N.I.C.)
(2) K&V 208 8"X12" BRACKETS BENEATHEACH TV LOCATION, ANCHOR THROUGH BACKOF CHASE CABINET TO BLOCKING IN WALL- VERIFY WITH TV LOCATIONS, PROVIDED ANDINSTALLED BY CONTRACTOR (AT FUTURESTATIONS, COUNTERMOUNT BRACKETS SHALLSTILL BE PROVIDED FOR FUTURE TVINSTALLATIONS)
2X FRT BLOCKING AT TVBRACKET LOCATIONS
FRT WOOD BLOCKINGIN CABINET @ TVS BYOWNER'S TV VENDOR
NOTE:E.C. TO PROVIDE CONDUITTO TV LOCATIONS ATDIALYSIS COUNTERS. TVCONNECTIONS TOCONDUIT SHALL BE MADEBY THE OWNER'SCOMMUNICATIONVENDOR.
PRIMER (BOTH SIDES)
PRIME FLANGE OF LEADFLASHING WITH SPM METAL
VENT STACKPLUMBING
MEMBRANE
LAP SEALANT AT ALL SIDES
FLEXIBLE FLASHING ADHERED
MASTIC SEALANTSET LEAD FLANGE IN
MIN.
8"
MIN. DOWN INTO PIPEROLL LEAD FLASHING 1"
8" MIN.
ROOF MEMBRANE (V.I.F.)
SCALE: 1" = 1'-0"PLUMBING VENT FLASHING DETAIL (TYP.)16
MBR. FLASHING CEMENT,MBR. UTILITY CEMENTOR ASPHALT
INSULATION (VERIFYAND MATCH EXISTINGCONDITION)
11A6.1
2"
2"
DOUBLE STUDS
CONTINUOUS RETAINER
2"
2"
A6.111
CONTINUOUS RETAINER
SCALE: 3" = 1'-0"TYPICAL CORNER GUARD DETAIL9
SCALE: 3" = 1'-0"TYPICAL CORNER GUARD DETAIL10
TOP OF RAIL 32" AFF
PROVIDE 2x FRT WOODBLOCKING BEHIND CHAIR RAIL
PAINTED CHAIR RAIL, WITHPROFILE AS SHOWN, EQUAL TOLEWIS LUMBER LLP 0013
SCALE: 6" = 1'-0"CHAIR RAIL DETAIL5
PAINTED 3" X 1/2" BACKER
SCALE: 6" = 1'-0"WOOD BASE DETAIL6
HOLD GYPSUM BOARD1/4" ABOVE CONCRETESLAB. PROVIDEBACKER ROD ANDSEALANT EACH SIDE
PAINTED WALLBASE, WITHPROFILE AS SHOWN,EQUAL TO LEWISLUMBER LLP 0040
7/16"
3/4"
41/
2"
PAINTED SHOEMOLDING
NOTE:CHAIR RAIL SHALL BEFURNISHED PRIMED BYOWNER'S MILLWORKVENDOR AND PAINTED &INSTALLED BY CONTRACTOR- SEE SHEET A2.8
NOTE:WOOD BASE SHALL BEFURNISHED PRIMED BYOWNER'S MILLWORKVENDOR AND PAINTED &INSTALLED BYCONTRACTOR - SEESHEET A2.8
PROVIDE 2x FRT WOODBLOCKING BEHIND BASE
CLEAR SILICONE CAULK
2"TY
PIC
AL
2" TYPICAL
WALL FINISHESSHALL BE APPLIEDPRIOR TOCORNERGUARDINSTALLATION
WALL STUDS
SCREWS AT 18"STAGGEREDVERTICALLY
CONTINUOUSSHOCK CUSHION CONTINUOUS
RETAINER
NOTE: SETBOTTOM OFCORNER GUARDDIRECTLY AT TOPOF BASE (TYPICAL)
TEXTURED HIGHIMPACT SNAP-ONCOVER
GYPSUM BOARD
SCALE: 1:1CORNER GUARD DETAIL11
A6.1
TMW
JLR
DETAILS
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
A2
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
WA
403
-13-
2017
AD
DE
ND
UM
#4M
MW
A4
SCALE: 3/4" = 1'-0"RATED WALL STENCILS11
1 HOUR RATED WALLPROTECT ALL OPENINGS AND PENETRATIONS
SMOKE PARTITIONPROTECT ALL OPENINGS AND PENETRATIONS
3"(T
YP
ICA
L)
NOTES:1. STENCILS SHALL BE APPLIED TO EACH AND EVERY RATED WALL IN THE FACILITY.2. SOME JURISDICTIONS MAY HAVE A SPECIFIC HEIGHT REQUIREMENT FOR THE
LETTERING AND SPACING, ADJUST ACCORDINGLY.3. SOME JURISDICTIONS MAY HAVE A SPECIFIC WORDING/PHRASING
REQUIREMENTS FOR THE STENCIL, ADJUST ACCORDINGLY.4. STENCILS SHALL BE APPLIED SO THAT THE BOTTOM OF THE LETTERS ARE 6"
ABOVE THE CEILING GRID AND AT EVERY 10'-0" ON CENTER ALONG THE LENGTHOF THE WALL.
(TYPICALLY ON TENANT DEMISING WALLS)
(TYPICALLY ON STORAGE ROOMS, MED RECORDS, MEDWASTE, JANITOR CLOSET, WATER TREATMENT, ETC.)
SCALE: 1 1/2" = 1'-0"PARTITION 'A'1
A
SCALE: 1 1/2" = 1'-0"PARTITION 'B'2
B B6
SCALE: 1 1/2" = 1'-0"PARTITION 'C'3
C
SCALE: 1 1/2" = 1'-0"PARTITION 'D' - 1 HOUR FIRE RATED WALL5
D
1 HR FIRE RATED ASSEMBLYUL DESIGN NO. U465
'B6' DENOTES6" METAL STUD
NOTES:1. DAPW REQUIRED AT ALL TOILET
ROOMS, LOUNGE "WET WALL"AREAS, AND ALL WALL AREASADJACENT TO SINKSTHROUGHOUT.
2. PROVIDE CONTROL JOINTS INGYPSUM BOARD AT 30'-0" O.C.MAXIMUM, SEE SPECIFICATIONMANUAL SECTION 09260 FORMORE INFORMATION
3. CONTRACTOR SHALL VERIFYLIMITING HEIGHTS OF METALSTUDS WITH MANUFACTURERPRIOR TO COMPLETION OF BIDS.CONTRACTOR SHALL PROVIDETHICKER GAUGE STUD ASREQUIRED.
NOTES:1. DAPW REQUIRED AT ALL TOILET
ROOMS, LOUNGE "WET WALL"AREAS, AND ALL WALL AREASADJACENT TO SINKSTHROUGHOUT.
2. PROVIDE CONTROL JOINTS INGYPSUM BOARD AT 30'-0" O.C.MAXIMUM, SEE DETAIL #4 ON THISSHEET, SEE SPECIFICATIONMANUAL SECTION 09260 FORMORE INFORMATION
3. CONTRACTOR SHALL VERIFYLIMITING HEIGHTS OF METALSTUDS WITH MANUFACTURERPRIOR TO COMPLETION OF BIDS.CONTRACTOR SHALL PROVIDETHICKER GAUGE STUD ASREQUIRED.
4. PROVIDE SMOKE SEALS FORSMOKE PARTITION - VERIFYLOCATION ON PLANS. ALLPENETRATIONS THROUGH SMOKEPARTITIONS SHALL BE FILLEDWITH A MATERIAL THAT ISCAPABLE OF MINIMIZING THETRANSFER OF SMOKE ANDPROTECTED BY AN APPROVEDDEVICE THAT IS DESIGNED FORTHE SPECIFIC PURPOSE.EQUIVALENT TO STI SMOKE ‘N’SOUND SEALANT.
5. SEE DETAIL #10 FOR PARTITIONHEAD ANCHORAGE. TYPICAL ATALL PARTITIONS.
NOTES:1. DAPW REQUIRED AT ALL TOILET
ROOMS, LOUNGE "WET WALL"AREAS, AND ALL WALL AREASADJACENT TO SINKSTHROUGHOUT.
2. PROVIDE CONTROL JOINTS INGYPSUM BOARD AT 30'-0" O.C.MAXIMUM, SEE SPECIFICATIONMANUAL SECTION 09260 FORMORE INFORMATION
3. CONTRACTOR SHALL VERIFYLIMITING HEIGHTS OF METALSTUDS WITH MANUFACTURERPRIOR TO COMPLETION OF BIDS.CONTRACTOR SHALL PROVIDETHICKER GAUGE STUD ASREQUIRED.
NOTES:1. DAPW REQUIRED AT WALLS AND
CEILINGS IN ALL TOILET ROOMS ANDLOUNGE "WET WALL" AREAS, ANDALL WALL AREAS ADJACENT TO SINKSTHROUGHOUT.
2. CONTRACTOR SHALL APPLYELASTOMERIC FIRE STOP COATINGAT ALL ROOF/CEILING ORROOF/FLOORING INTERSECTIONS.ELASTOMERIC FIRE STOP COATINGMUST BE WATER BASED AND BEAPPLIED EITHER BY SPRAY OR BRUSHAPPLICATION AT ALL CONSTRUCTIONJOINTS AT TOP OF WALL: SEE SPECS
3. CONTROL JOINTS IN GYPSUM BOARDSHALL BE 30'-0" O.C. MAXIMUM ANDSHALL BE RATED, SEE DETAIL #4 ONTHIS SHEET AND SPECIFICATIONMANUAL SECTION 09260 FOR MOREINFORMATION.
4. CONTRACTOR SHALL VERIFY LIMITINGHEIGHTS OF METAL STUDS WITHMANUFACTURER PRIOR TOCOMPLETION OF BIDS. CONTRACTORSHALL PROVIDE THICKER GAUGESTUD AS REQUIRED.
5. VERIFY LOCATION ON PLAN OF FIRERATED WALLS AND FIRE/SMOKEBARRIER WALLS, ALL PENETRATIONSSHALL BE SEALED TO PREVENT THEPASSAGE OF FIRE.
6. SEE DETAIL #10 FOR PARTITION HEADANCHORAGE. TYPICAL AT ALLPARTITIONS.
NOTE: 1 HR FIRE RATED WALL SHALL RUNCONTINUOUS FROM FLOOR SLAB BELOW TOUNDERSIDE OF ROOF DECK ABOVE
HOLD GYPSUM BOARD 1/4" ABOVE CONCRETE SLAB.PROVIDE BACKER ROD AND SEALANT EACH SIDE
OPTION: EXTEND 18GA. STEEL STUD TOSTRUCTURE AT 4'-0"O.C. MAXIMUM3 5/8"-20GA. STEEL STUD BRACINGAT 48" O.C., ALTERNATE SIDES
BATT INSULATION
(4) #8 x 1/2" METAL SCREWS,BRACING TO RUNNER
CEILING AS SCHEDULED
3 5/8"-20GA. STEEL FRAMING AT 16"O.C. MAXIMUM WITH 1-LAYER 5/8"TYPE 'X' GYPSUM BOARD OR DAPWEACH SIDE
.177 X 1" MINIMUM SHOT-INANCHOR AT 24" O.C. MAXIMUMSEALANT EACH SIDE - HOLDGYPSUM BOARD 1/2" OFF FINISHFLOOR
45°-
60°
OPTION: EXTEND 18GA. STEELSTUD TO STRUCTURE AT4'-0"O.C. MAXIMUM
3 5/8"-20GA. STEEL STUD BRACINGAT 48" O.C., ALTERNATE SIDES
(4) #8 x 1/2" METAL SCREWS,BRACING TO RUNNER
SOUND BATT INSULATION
CEILING AS SCHEDULED
3 5/8"-20GA. STEEL FRAMING AT16" O.C. MAXIMUM WITH 1-LAYER5/8" TYPE 'X' GYPSUM BOARD ORDAPW EACH SIDE
.177 X 1" MINIMUM SHOT-INANCHOR AT 24" O.C. MAXIMUM
SEALANT EACH SIDE
45°-
60°
SEALANT EACH SIDEPARTITION HEAD ANCHORAGE(SEE DETAIL #9 ON THIS SHEET)(TYPICAL ALL PARTITIONS)
SOUND BATT INSULATION
SOUND BATT INSULATION
CEILING AS SCHEDULED
.177 X 1" MINIMUM SHOT-INANCHOR AT 24" O.C. MAXIMUM
3 5/8"-18GA. STEEL FRAMINGAT 16" O.C. MAXIMUM WITH1-LAYER 5/8" TYPE 'X' GYPSUMBOARD OR DAPW EACH SIDE
SEALANT EACH SIDE
FILL EXPOSED FLUTES AND VOIDS WITHFIRE-SAFING INSULATION - CUT BACKEXISTING ROOF INSULATION TO ACHIEVERATING TO STRUCTURAL DECK ANDPATCH AS NECESSARY
NOTE: PROVIDE SMOKESEALS FOR SMOKE WALLLOCATIONS
SOUND BATT INSULATION
SOUND BATT INSULATION
EXISTING STRUCTURE
CEILING AS SCHEDULED
1-LAYER 5/8" TYPE 'X' GYPSUMBOARD OVER 3 5/8"-18GA. STEELFRAMING AT 16" O.C.
.177 X 1" MINIMUM SHOT-INANCHOR AT 24" O.C. MAXIMUM
SEALANT EACH SIDE
BOTTOM OF STRUCTURE ABOVE(V.I.F.)
BOTTOM OF STRUCTURE ABOVEELEV. ~18'-0" TO 20'-0"
BOTTOM OF STRUCTURE ABOVEELEV. ~18'-0" TO 20'-0"
BOTTOM OF STRUCTURE ABOVEELEV. ~18'-0" TO 20'-0"
HOLD GYPSUM BOARD 1/4" ABOVE CONCRETE SLAB.PROVIDE BACKER ROD AND SEALANT EACH SIDE
HOLD GYPSUM BOARD 1/4" ABOVECONCRETE SLAB. PROVIDE BACKERROD AND SEALANT EACH SIDE
EXISTING FLOOR SLAB
EXISTING FLOOR SLAB
EXISTING FLOOR SLAB
EXISTING FLOOR SLAB
EXISTING STRUCTURE
EXISTING STRUCTURE
EXISTING STRUCTURE
SCALE: 1 1/2" = 1'-0"PARTITION 'E'6
E
SOLID SURFACE CAP PROVIDED BYOWNER'S MILLWORK VENDOR ANDINSTALLED BY CONTRACTOR
1-LAYER 5/8" GYPSUM BOARD (DENS ARMORPLUS WHERE REQUIRED IN TREATMENT ANDPRIVATE DIALYSIS ROOMS ONLY) EACH SIDE 35/8"-20 GA. STEEL FRAMING AT 16" O.C. MAXIMUM
PROVIDE 3 1/2" TUBE STEEL SUPPORTSSECURED TO CONCRETE SLAB WITHCONCRETE EXPANSION BOLTS AT 4'-0" O.C.AND AT ENDS OF LONG PARTIAL-HEIGHTWALL RUNS - POSITION TO LIMITINTERFERENCE WITH PLUMBING ANDELECTRICAL RUNS.
.177 X 1" MINIMUM SHOT-INANCHOR AT 24"O.C. MAXIMUM
SEALANT EACH SIDE
7"
TOP OF CAP ELEV. = 103'-6" OR 104'-0"(SEE FLOOR PLAN SHEET A2.0)
FINISH FLOOR ELEV. = 100'-0"
HOLD GYPSUM BOARD 1/4"ABOVE CONCRETE SLAB.PROVIDE BACKER RODAND SEALANT EACH SIDE
PROVIDE FRT WOOD BLOCKINGIN WALL AT DIALYSIS CHASELOCATIONS
EXISTING FLOOR SLAB
NOTE: THE CONTRACTORMUST PROVIDE TUBE STEELSUPPORTS SIMILAR TO THISDETAIL AT ALL MILLWORKAND METAL STUD FRAMEDHALF-WALLS.
C6
'C6' DENOTES6" METAL STUD
6"6"
SCALE: 1 1/2" = 1'-0"PARTITION 'G'8
G
BOTTOM OF STRUCTUREABOVE (V.I.F.)
CEILING AS SPECIFIED
PROVIDE 3 5/8" FURRING, VAPORBARRIER, AND 5/8" GYP BOARD(DENS ARMOR PLUS WHEREREQUIRED) AT ALL EXTERIORWALLS, BY LANDLORD
SOUND BATT INSULATION
EXISTING STRUCTURE
SEALANT, BYLANDLORD
EXISTING FLOOR SLAB
HOLD GYPSUM BOARD 1/2" ABOVEFLOOR SLAB. PROVIDE BACKERROD AND SEALANT, BY LANDLORD
NOTES:1. DAPW REQUIRED AT ALL TOILET
ROOMS, LOUNGE "WET WALL"AREAS, AND ALL WALL AREASADJACENT TO SINKSTHROUGHOUT.
2. PROVIDE CONTROL JOINTS INGYPSUM BOARD AT 30'-0" O.C.MAXIMUM, SEE DETAIL #4 ON THISSHEET, SEE SPECIFICATIONMANUAL SECTION 09260 FORMORE INFORMATION
3. CONTRACTOR SHALL VERIFYLIMITING HEIGHTS OF METALSTUDS WITH MANUFACTURERPRIOR TO COMPLETION OF BIDS.CONTRACTOR SHALL PROVIDETHICKER GAUGE STUD ASREQUIRED.
THERMAL BATT INSULATION,BY LANDLORD
.177 X 1" MINIMUM SHOT-INANCHOR AT 24" O.C. MAXIMUM,BY LANDLORD
EXTEND GYPSUM BOARD, VAPORBARRIER, AND INSULATION TOSTRUCTURAL DECK ABOVE, BYLANDLORD
EXISTING EXTERIOR WALLASSEMBLY, VERIFY DEPTH OFWALL IN FIELD
EXTERIOR
SCALE: 1 1/2" = 1'-0"PARTITION 'F'7
F
BOTTOM OF STRUCTUREABOVE (V.I.F.)
CEILING AS SPECIFIED
SOUND BATT INSULATION
EXISTING STRUCTURE
SEALANT
EXISTING FLOOR SLAB
HOLD GYPSUM BOARD 1/2" ABOVEFLOOR SLAB. PROVIDE BACKERROD AND SEALANT
NOTES:1. DAPW REQUIRED AT ALL TOILET
ROOMS, LOUNGE "WET WALL"AREAS, AND ALL WALL AREASADJACENT TO SINKSTHROUGHOUT.
2. PROVIDE CONTROL JOINTS INGYPSUM BOARD AT 30'-0" O.C.MAXIMUM, SEE DETAIL #4 ON THISSHEET, SEE SPECIFICATIONMANUAL SECTION 09260 FORMORE INFORMATION
3. CONTRACTOR SHALL VERIFYLIMITING HEIGHTS OF METALSTUDS WITH MANUFACTURERPRIOR TO COMPLETION OF BIDS.CONTRACTOR SHALL PROVIDETHICKER GAUGE STUD ASREQUIRED.
4. CONTRACTOR SHALL BERESPONSIBLE FOR INSTALLINGTHE EIFS SYSTEM PER THEMANUFACTURERSRECOMMENDATIONS.CONTRACTOR SHALL BERESPONSIBLE FOR INCLUDINGITEMS NOT INDICATED IN THESEDRAWINGS, BUT SPECIFIED BYTHE MANUFACTURER IN THE BID,SHOP DRAWINGS, ANDCONSTRUCTION OF THISPROJECT.
EXTERIOR
EXISTING EXTERIOR WALL BYLANDLORD. ENSURE DENS ARMORPLUS WALL WHERE REQUIRED.
34" TREATED PLYWOOD BLOCKING
EXTEND FROM 3'-0" TO 7'-0" A.F.F.SEE FLOOR PLAN FOR LOCATION
NOTES:1. FIRE RETARDANTTREATED (FRT) BLOCKINGIS REQUIRED FOR ALLWALL MOUNTED/ WALLHUNG ITEMS.
2. ALL WOOD BLOCKINGAND BACKING MUST BEFIRE RETARDANT,TREATED & FACTORYSTAMPED.
SCALE: 3" = 1'-0"PLYWOOD BLOCKING DETAIL9
FIRE RETARDANT WOOD BLOCKING (SEEWALL TYPE FOR BLOCKING SIZE
5/8" GYPSUM BOARD ORDAPW ON METAL STUDS (SEEWALL TYPE FOR STUD SIZE)
SCALE: 3" = 1'-0"IN RATED PARTITION4
5/8" TYPE 'X'GYPSUM BOARD
STEEL STUD(TYPICAL)
5/8" GAP
1/2" (MAXIMUM)GAP
1-5/8" SCREWS AT24" O.C.
(2) 5/8" TYPE 'X'GYPSUM BOARDSTRIPS
METAL OR VINYLCONTROL JOINT
SCALE: 3" = 1'-0"PARTITION HEAD ANCHORAGE10
1"MIN.
5/8" DEFLECTION GAP
LINE OF STRUCTURE ABOVE,CONTRACTOR SHALL VERIFYCONSTRUCTION TYPE.
SLIPTRACK SYSTEMSLOTTED TRACK
11/
4"
PROVIDE 2" x 20 GA STEELSTRAPS OR Z-BARS AT EACHBRACING MEMBER, WHENWALL RUN IS PARALLEL TOFLUTES IN METAL DECK.
FASTENERS AT 16"OC (MAXIMUM)(TYPICAL) STUD WALL
WIDTH VARIES
FRAMING SCREWS, TIGHTENAPPROPRIATELY TO ALLOW PROPERSLIP TRACK DEFLECTION (TYPICAL)
1"MIN.
STEEL STUD PARTITIONBRACING
LINE OF STRUCTURE ABOVE,CONTRACTOR SHALL VERIFYCONSTRUCTION TYPE.
PROVIDE 2" x 20 GA STEELSTRAPS OR Z-BARS AT EACHBRACING MEMBER, WHENWALL RUN IS PARALLEL TOFLUTES IN METAL DECK.
CLASS 'A' FIRE RATED FRP PANEL / INPROWALL PROTECTION PANEL. SET PANEL 1"BELOW RUBBER BASE AND SET INCONTINUOUS BEAD OF SILICONESEALANT AT TOP AND BOTTOM4" OR 6" RUBBER BASE SET IN SILICONE SEALANT ANDTHOROUGHLY GLUED TO PANEL (OVERLAP INPRO WALLPANEL BY 1/4", PER MANUFACTURER'S INSTALLATIONDIRECTIONS. USE ADHESIVE AS RECOMMENDED BYMANUFACTURER)
5/8" TYPE X DAPW
CLASS 'A' FIRE RATED FRPPANEL / INPRO WALLPROTECTION PANEL. SETPANEL 1
4" ABOVE BASE AND SETIN CONTINUOUS BEAD OFSILICONE SEALANT AT TOP ANDBOTTOM
6" 1/8" THICK RESINOUS FLOORINGOVER PREPARED CONCRETE SLAB(APPLY W/ INTEGRAL COVE BASEAS SHOWN)
RESINOUS FLOORING
LVT/SV/SC FLOORING
SCALE: 3" = 1'-0"BASE WALL PROTECTION BASE DETAIL12
5/8" TYPE X DAPW
E.G. INFECTIOUS WASTE ROOMAND FTM/REPAIR ROOM
E.G. @ PATIENT SCALE AREAAND CORRIDORS
NOTE: PROVIDE MOLDEDOUTSIDE CORNER PIECES FORRUBBER BASE AT ALL OUTSIDECORNER CONDITIONS.
BEAD OF SILICONE SEALANT ATTOP AND BOTTOM OF BASE.
NOTE: STOP INPRO VERTICALSEAM TRIMS @ 4" AFF BEHINDRUBBER BASE TO PREVNETBULGING OF BASE.
CORNER BEAD ANDJOINT COMPOUND
5/8" GYPSUM BOARDON METAL STUDS
TAPE AND JOINTCOMPOUND OVER CORNERREINFORCEMENT
SEE FLOOR PLANS FORPARTITION TYPE
NOTE: ONE HOURPARTITION IS SIMILARWITH TYPE 'X' GYPSUMBOARD AND FIRESEALANT AT ALLPENETRATIONS ANDSEAMS
5" NOMINAL WALLTHICKNESSTYPICAL U.N.O.
SCALE: 3" = 1'-0"TYPICAL PARTITION CORNER15
5/8" TYPE 'X' GYPSUMBOARD ON METAL STUDS
TAPE AND JOINT COMPOUNDOVER JOINT REINFORCEMENT
TAPE AND JOINTCOMPOUND OVER CORNERREINFORCEMENT
5" NOMINAL WALLTHICKNESS TYPICALUNLESS NOTED OTHERWISE
NOTE: ONE HOURPARTITION SHALL BECONSTRUCTED WITHTYPE 'X' GYPSUM BOARDAND FIRE SEALANT ATALL PENETRATIONS ANDSEAMS
TYPE 'X' GYPSUM BOARD - VARYNUMBER OF LAYERS FOR REQUIREDFIRE RATING (1 HOUR PARTITIONSHOWN)
NON-RATEDPARTITION
SMOKEPARTITION ORRATED WALL
SMOKE PARTITION/RATED
SCALE: 3" = 1'-0"WALL TO TYPICAL PARTITION INTERSECTION16
5/8" GYPSUM BOARDON METAL STUDS
TAPE AND JOINT COMPOUNDOVER JOINT REINFORCEMENT
TAPE AND JOINTCOMPOUND OVER CORNERREINFORCEMENT
SEE FLOOR PLANS FORPARTITION TYPE
5" NOMINAL WALLTHICKNESS TYPICALUNLESS NOTED OTHERWISE
NOTE: ONE HOURPARTITION IS SIMILARWITH TYPE 'X' GYPSUMBOARD AND FIRE SEALANTAT ALL PENETRATIONSAND SEAMS
SCALE: 3" = 1'-0"TYPICAL PARTITION INTERSECTION14
SMOKEPARTITIONOR RATED
WALL
WATER TREATMENT
SCALE: 3" = 1'-0"RESINOUS FLOORING WATERPROOF DETAIL13
BASE MUST BE ADHEARED TOWALL NOT PANEL
HOLD GYPSUM BOARD 1/4"ABOVE CONCRETE SLAB.PROVIDE BACKER ROD ANDSEALANT EACH SIDE
WATER TREATMENT ROOM STORAGE ROOM
6"
5/8" TYPE 'X' GYPSUM BOARD(OR CLASS 'A' FIRE RATEDFRP ON 5/8" DAPW WHEREOCCURS) ON 3 5/8" METALSTUDS AT 16" O.C., MAXIMUM
3 1/2" SOUND ATTENUATIONBLANKETS TO DECK
CONTINUOUS J-MOLD EA.SIDE
8'-0" HIGH, 5/8" A-C FRTPLYWOOD
5/8" DENS ARMOR PLUSWALLBOARD
RESINOUS FLOORINGOVER PREPAREDCONCRETE SLAB (APPLYWITH INTEGRAL COVE BASEAS SHOWN)
HOLD GYPSUM BOARD 1/4" ABOVECONCRETE SLAB. PROVIDE BACKERROD AND SEALANT EACH SIDE
CLASS 'A' FIRE RATED FRP(ALL WALLS) TO 8'-6" A.F.F., SETIN CONTINOUS BEAD OFSILICONE SEALANT
CAULK ALL JOINTS WITHSEALANT (TOP ANDBOTTOM)
DUROCK CEMENTBOARD TO 12" A.F.F.PERIMETER OF ROOM.
RESINOUS FLOORINGOVER PREPAREDCONCRETE SLAB
BASE AS SCHEDULED
CLASS 'A' FIRE RATED FRP(ALL WALLS) TO 8'-6" A.F.F., SETIN CONTINOUS BEAD OFSILICONE SEALANT
NOTE: IF WATER TREATMENT ROOMOCCURS AT AN EXTERIOR WALL,CONTRACTOR MUST COORDINATEREQUIRED INTERIOR WALL FINISHES
PROVIDE 6" STRIP OF 5/8"MARINE BOARD BEHIND 6"RESINOUS COVE BASE
CONTROL JOINT
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
A6.0
TMW
JLR
DETAILS
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
A2
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
W
A4
A4
03-1
3-20
17A
DD
EN
DU
M#4
MM
W
1" DIAMETER FLEXIBLE CONDUITINSTALLED BY ELECTRICALCONTRACTOR UNDER SLAB
3'-6
"
1'-0
"
5'-2"
SEE DETAIL OF SCALESECTION AT FLOOR
PROVIDE DEPRESSED CONCRETESLAB AREA 42" X 62" X 6" (VERIFY)MINIMUM CENTER SCALE IN PITAND PARALLEL TO WALL.
32" X 50" SCALE
PLANSCALE: 3/4"=1'-0"
COORDINATE INTSALLATION OFGRAB BAR AND SCALE ELECTRONICREADOUT AND CONDUITS UP FROMFLOOR SLAB IN WALL
PLASTIC LAMINATE PATIENTSHELF. SEE DETAIL #2 THISSHEET
3'-0
"
1" DIAMETER FLEXIBLECONDUIT INSTALLED BYELECTRICAL CONTRACTOR
32" X 50" ELECTRONIC SCALE(VERIFY SIZE, MAKE AND MODELOF SCALE W/ OWNER)
ELEVATIONSCALE: 3/4"=1'-0"
42" GRAB BAR (WITH PEENEDSAFETY GRIP), PROVIDE FRTBLOCKING IN WALL
RECESSED ELECTRONIC READOUT BOX (O.F.I.C.) OFFSETFROM SCALE AND FASTENED TO 2 X 4 FRT WOOD STUDSEACH SIDE OF BOX - VERIFY DEPTH OF READOUT BOX (IFDEPTH OF WALL FURRING WILL NOT ACCOMODATE BOX,MOVE READOUT LOCATION TO SIDE WALL, VERIFY FINALLOCATION WITH ARA PROJECT MANAGER)
METAL STUD FRAMINGEACH SIDE OF FRTWOOD STUDS
BASE AS SCHEDULED
3'-6"CLEAR
3'-6"CLEAR
INPRO WALL PROTECTIONTO UNDERSIDE OF WALL CAP
2'-1
0"TO
TOP
OF
PA
TIE
NT
SH
ELF
4"
6"
EXISTING CONCRETEFLOOR SLAB
PARTIAL HEIGHT WALL BYGENERAL CONTRACTOR
MODERN FLAMES AL60CLX2 ELECTRICFIREBOX W/ NO HEAT ELEMENT
CONTRACTOR TO PROVIDEPOWER AS REQUIRED
STACK STONE (FP-1 - SEE SHEETA2.8) OVER 5/8" CEMENT BOARDOR APPROVED EQUAL ON 2 1/2"METAL STUD FRAMING
CONTRACTOR SHALLCOORDINATE FRAMINGGAUGE AND SPACINGWITH STONE VENEERAND SHEATHING.
CONTRACTOR TO PROVIDEPOWER / DATA, AS REQUIRED,TO IN-WALL MOUNT - SEEELECTRICAL PLANS
STEEL SHELF ANGLE BYCONTRACTOR TO CARRYMILLWORK MANTLE BYMILLWORK VENDOR
FLAT PANEL TV W/ IN-WALLMOUNT (O.F.O.I.)
5"
6"
PROVIDE GAP FOR VENTING ASREQUIRED BY FIREBOX MFR.
1'-6
"2'
-11/
2"4"
VIF
WIT
HO
WN
ER
PR
OV
IDE
DTV
SCALE: 1" = 1'-0"TV/FIREPLACE SECTION10
STONE VENEER OVER 5/8" CEMENTBOARD OR APPROVED EQUAL ON 2 1/2"METAL STUD FRAMING
SEE FLOOR PLANFOR WALL TYPE
IN-WALL FLAT PANEL TV MOUNT(O.F.O.I.): GC SHALL VERIFYEXACT MODEL WITH OWNER'S TVCOMMUNICATION VENDOR, ANDOBTAIN CUT SHEET OF MOUNTFROM VENDOR BEFOREINSTALLATION (GLOSS BLACK)
5/8" GYPSUM BOARD AT TVRECESS. CONTRACTORSHALL PAINT TO MATCHSTONE VENEER COLOR
5/8" GYPSUM BOARD AT TVRECESS. CONTRACTOR SHALLPAINT TO MATCH STONEVENEER COLOR
A-1
FINISHEDFLOOR
MILLWORK BYOWNER'S MILLWORKVENDOR, LAYOUTMAY VARY
SEE DETAIL #7 ON THIS SHEETFOR LIGHT COVE DETAIL
SCALE: 1" = 1'-0"PATIENT SHELF DETAIL2
ISOMETRIC
SECTION
1'-6"
1'-0"
1" RADIUSCORNERS(TYPICAL)
34" A.F.F.
FACE OF WALL, FINISHAS SCHEDULED
SCREW CLEAT ENDSAND BACK INTO SOLIDBLOCKING BEHIND WALL
PLASTIC LAMINATECLEAT AT BACK
PLASTIC LAMINATEWRITING SURFACE
PLASTIC LAMINATEANGLED BRACE
NOTE:SHELF SHALL BEFURNISHED BY OWNER'SMILLWORK VENDOR ANDINSTALLED BYCONTRACTOR
PAINT GRADEPLYWOOD - PAINTEDTO MATCH WALL
EXTERIORINTERIOR
SOLID SURFACEWALL CAP BYOWNER'S MILLWORKVENDOR, I.B.C.
PARTIAL HEIGHTWALL BY GENERALCONTRACTOR, SEEDETAIL #6 ON SHEETA6.0. (DENS ARMORPLUS WHEREREQUIRED.)
PRE-FINISHED INSULATEDMETAL PANEL BELOWMULLION TO MATCHSTOREFRONT COLOR, BYLANDLORD
1'-1
1/2"
SCALE: 1" = 1'-0"SILL AT CABINET DETAIL12
3'-6
"
EXTERIORINTERIOR
SOLID SURFACEWALL CAP BYOWNER'S MILLWORKVENDOR, I.B.C.
PRE-FINISHED INSULATEDMETAL PANEL BELOWMULLION TO MATCHSTOREFRONT COLOR, BYLANDLORD
1'-1
1/2"
SCALE: 1" = 1'-0"SILL AT HALF WALL DETAIL13
3'-6
"
LAMINATE SILL BYOWNER'S MILLWORKVENDOR, I.B.C.
EXTERIORINTERIOR
PRE-FINISHED INSULATEDMETAL PANEL BELOWMULLION TO MATCHSTOREFRONT COLOR, BYLANDLORD
1'-1
1/2"
SCALE: 1" = 1'-0"SILL DETAIL14
1'-2
3/4"
1" INSULATED GLAZING,BY LANDLORD
1" INSULATEDGLAZING, BYLANDLORD
1" INSULATED GLAZING,BY LANDLORD
V.I.F.
V.I.F.
V.I.F.
PAINT GRADEPLYWOOD - PAINTEDTO MATCH WALL
NOTE: REFER TO PARTITIONTYPE 'E' FOR STRUCTURALTUBE STEEL SUPPORTSREQUIRED IN HALF WALL
PARTIAL HEIGHTWALL BY GENERALCONTRACTOR, SEEDETAIL #6 ON SHEETA6.0. (DENS ARMORPLUS WHEREREQUIRED.)
PARTIAL HEIGHT WALL BYGENERAL CONTRACTOR(DENS ARMOR PLUSWHERE REQUIRED.)
SCALE: 1 1/2" = 1'-0"PLUMBING SLAB CUT DETAIL4
COMPACTED FILL
CONCRETE SLAB WITH W.W.M.OVERCUT SLAB BY 4" ALL SIDE
V.I.
F.
COMPACTED PEA GRAVEL
POUR BACK CONCRETE SHALL BEEQUAL TO THAT OF FLOOR SLABWITH VAPOR BARRIER ANDINSTALLED PER MANUFACTURER'SINSTRUCTIONS
#4 REBAR AT 120.C. STAGGERED
SCALE: 1 1/2" = 1'-0"SECTION @ ACT CLOUD SOFFIT6
SUSPENDED ACOUSTICALCEILING SYSTEMTHROUGHOUT ROOM ATSPECIFIED HEIGHT
EXTRUDED "AXIOM"ALUMINUM TRIM PIECE BYACOUSTICAL CEILING"CLOUD" GRIDMANUFACTURER - SEESPECIFICATIONS (PROVIDEIN ACCENT COLOR)
6"
SUSPENDED ACOUSTICALCEILING SOFFIT "CLOUD"SYSTEM WITH HEAVY DUTYGRID - SEE SPECIFICATIONS
VA
RIE
S
SEE SPECIFICATIONS FORACOUSTICAL CEILING TILESTO BE UTILIZED IN "CLOUD"
4"TYP.
6" TYP
.
4" TRENCH DRAIN, SETFLUSH WITH SLAB, SEEFLOOR PLAN ANDPLUMBING DRAWINGS
OPENING BEYOND,RUN BASE TO OUTEREDGE OF OPENING ANDPROVIDE S.S. 'J' CORNER
RESINOUS FLOORINGBASE BEYOND
RESINOUS FLOORING
BEVEL LAST 4" ADJACENT TOTRENCH DRAIN TO A DEPTH OF1/2" TO ALLOW FLOORING TOSLOPE TOWARD THE DRAIN
4"TYP.
4" TYP
.
4"TYP.
4" TYP
.
CORNERGUARDS (TYPICAL)
4'-0" MIN.
STORAGEWATERTREATMENTROOM
SCALE: 1 1/2" = 1'-0"WATER TREATMENT DRAIN/THRESHOLD3
PLAN
SECTION
10 MIL POLY VAPOR BARRIERTAPED TO EXISTING VAPORBARRIER
SCALE: 3" = 1'-0"TYPICAL BULKHEAD DETAIL5
3-5/8" METAL STUDS
CEILING SYSTEM ASSPECIFIED
3-5/8" METAL STUDS KICKER4'-0" O.C. FASTENED TO ROOFSTRUCTURE ABOVE
5"
2" TYP
.6"
CEILING HEIGHTS VARY -SEE PLAN FOR MOREINFORMATION
CORNER BEAD (TYPICAL)
4"V
.I.F.RUBBER BASE. G.C.
SHALL TRIM TO FITAT TOE KICK.
MILLWORK BYOWNER'S MILLWORKVENDOR
A-1
SCALE: 3" = 1'-0"TOE KICK / BASE DETAIL11 SCALE: 3" = 1'-0"
LIGHT COVE DETAIL AT FIREPLACE7
5"
AT FIREPLACE
WALL PARTITION ASNOTED ON SHEET A2.0
CEILING SYSTEM ASSPECIFIED
MINI LED COVE FIXTURE - SEEELECTRICAL DRAWINGS
STONE VENEER - EXTENDSTONE VENEER INTOLIGHT POCKET AREA
5"
2"
5"
METAL STUD RUNNER CHANNEL
5/8" GYPSUM BOARD
SCALE: 3" = 1'-0"WALL AT WINDOW MULLION DETAIL9
WINDOW MULLION
1"
5/8" TYPE 'X' GYPSUM BOARD ONBOTH SIDES OF METAL STUDS (SEEA2.0 FOR WALL TYPE DETAILS)
PREFINISHED BREAK-MTL. CLOSURETO MATCH WINDOW SYSTEM
3/8" THICK CLOSED CELL NEOPRENEFILLER
NOTE: DO NOTMECHANICALLYFASTEN WALL TOWINDOW MULLION
3"3"
3" REF.
MIN
.
FRAME ANCHOR BOLTS(O.F.I.C.) SET FRAME LEVEL.
ALUMINUM RIM KIT. BUTT JOINTALUMINUM RIM TO ADJACENTFLOORING PROVIDING A FLUSHTRANSITION
FLOORING TO EDGE OFSUBFRAME
EXISTINGCONCRETE SLAB
3" 'Z' CHANNEL SCALE SUBFRAME(O.F.I.C.). SET INTO CONCRETE PRIORTO INSTALLATION OF SCALE.CHANNELS FOR SCALE
FRAME (O.F.I.C.)DETAIL AT SUBFRAMESCALE: 3"=1'-0"VAPOR BARRIER
SCALE: VARIESIN-FLOOR SCALE DETAIL1
SR INSTRUMENTS 463
CONCRETE SLAB
32" X 50" SCALE (O.F.I.C.)
SCALE TOP PLATE (O.F.I.C.)6"
VARIESSEE SHEET A2.5
CEILING SYSTEM ASSPECIFIED
ACT CEILING
(VARIES - SEESHEET A2.5)
5/8" GYPSUM BOARD ON3 5/8" METAL STUDS AT16" O.C. PROVIDEBRACING AS REQUIRED.
GYP BOARD SOFFIT
SCALE: 3" = 1'-0"TYPICAL SOFFIT DETAIL8
VA
RIE
SS
EE
SH
EE
TA
2.5
SEE FLOOR PLAN SHEETA2.0 AND DETAILS ONSHEET A6.0 FORPARTITION TYPES
KICK TO WALL ORSTRUCTURE ABOVE 4'-0"O.C. WITH 3 5/8" METALSTUDS
(VARIES - SEESHEET A2.5)
A6.2
TMW
JLR
DETAILS
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
W
A2
A2
A2
A2A2
A4
A4
A4
A4
03-1
3-20
17A
DD
EN
DU
M#4
MM
W
POWER AND DATA- SEE ELECTRICAL
14" x 14" REMOVABLEACCESS PANEL INCOUNTERTOP,CENTERED ABOVEVALVE BOX
G.F.I. ELEC.RECEPTACLEAT 48" A.F.F.
HINGED ACCESSPANEL
REMOVABLEPLASTIC LAMINATEPANEL FRONT
3'-0
"1'
-6"
2'-6
"
LOCKABLE PLASTICLAMINATE CABINETSWITH WIRE PULLS (TYP.)
CLEAR SILICONE CAULK (TYP.)
COUNTERTOP BACKSPLASHAND SIDESPLASH
LINE OF MOISTURERESISTANT GYPSUMWALLBOARD BEHINDCABINETS TO 48" A.F.F.
EMERGENCY EYE WASH SEEPLUMBING DRAWINGS FORMORE INFORMATION.INSTALLATION SHALL NOTIMPEED FAUCET LOCATION.CAUTION - PROPER LOCATIONMUST BE DETERMIND BEFOREDRILLING HOLE FOREMERGENCY EYE WASH.
BASE AS SCHEDULED
INSTALL TRANSFORMER,SENSOR CONTROLS,MIXING VALVES, AND ELEC.RECEPT. 24" AFF.
REMOVABLE PLASTICLAMINATE PANEL TOMATCH CABINET
OFFSET PIPING AS REQUIRED TOFIT BEHIND REMOVABLE PANEL
W3030
141SCALE: 3/8" = 1'-0"REPAIR / FTM4
LIGHT VALANCE
CONTRACTOR SHALLPROVIDE 2X4 FRTBLOCKING. SEE GENERALNOTE #4 THIS SHEET
2'-0"1'-3"1'-2"2'-6"
1" FILLER
DB14 DB15B30
PTD
144SCALE: 3/8" = 1'-0"STAFF LOCKERS5
1'-1"2'-0"
CLEAR SILICONECAULK (TYP.)
LOCKABLE PLASTICLAMINATE CABINETS WITHWIRE PULLS (TYP.)
COUNTERTOP W/BACKSPLASH ANDSIDESPLASH
LINE OF DENS ARMORPLUS WALLBOARD BEHINDCABINETS TO 48" A.F.F.
127SCALE: 3/8" = 1'-0"RECEPTION DESK1
14'-0"
GENERAL NOTES:1. LOCKERS ARE FURNISHED BY OWNER'S MILLWORK VENDOR.
GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION.2. GENERAL CONTRACTOR SHALL VERIFY SIZE, MANUFACTURER,
BLOCKING, AND ASSEMBLY REQUIREMENTS WITH OWNER.3. CONTRACTOR SHALL PROVIDE 2X4 FRT BLOCKING4. PER MICHIGAN BHS 2007 MINIMUM DESIGN STANDARDS, ANY
FIXED HORIZONTAL SURFACE BELOW 68" AFF IS NOT REQUIREDTO HAVE A SLOPED TOP OR SOFFIT.
G.F.I. ELECTRICALOUTLET AT 42" A.F.F.(TYP. FOR 2)
RECESSED WATERBOX FOR REFRIG. ICEMAKER AT 30" A.F.F.
ELECTRICAL OUTLETAT 42" A.F.F.
INSTALL INLINEFILTER IN BASECABINET FOR ICEMAKER
INSTALL REMOVABLELAMINATED PANELTO MATCH CABINETS.SET PANEL TOMAINTAIN ADAREQUIREMENTS FORCLEAR SPACE
CLEAR SILICONECAULK (TYP.)
ELEC. RECEPTACLE60" A.F.F.RECESSED IN WALLBEHINDMICROWAVE SHELF
BASE AS SCHEDULED
CONTRACTOR SHALLPROVIDE 2X4 FRTBLOCKING. SEEGENERAL NOTE #4THIS SHEET
LINE OF DENSARMOR PLUSWALLBOARDBEHIND CABINETSTO 48" A.F.F.
COUNTERTOP W/BACKSPLASH ANDSIDESPLASH
147SCALE: 3/8" = 1'-0"STAFF LOUNGE8
W3030 W3030 W3030
130SCALE: 3/8" = 1'-0"PRIVATE DIALYSIS2
POWER AND DATA(TYP.) - SEEELECTRICAL
REMOVABLEPLASTIC LAMINATEPANEL FRONT (TYP.)
BASE AS SCHEDULED
SURFACE MOUNTED GFIELECTRICAL RECEPTACLEINSIDE BASE CABINETFOR ELECTRIC EYEFAUCET (TYP.)
SENSOR CONTROL FAUCET (TYP.)
1" FILLER
PTD
BASE ASSCHEDULED
DESIGNATEDHANDICAPPEDLOCKER STICKER -VERIFY LOCATIONWITH ARA PROJECTMANAGER
GENERAL NOTES - MILLWORK1. ALL MILLWORK INCLUDING CABINETS, COUNTERTOPS, DIALYSIS CHASE
CABINETS AND COUNTERTOPS, IN CABINET SOAP AND PAPER TOWELDISPENSER, WALL CAPS, WOOD TRIM, ETC. IS PROVIDED BY THEOWNER'S MILLWORK VENDOR AND INSTALLED BY THE G.C. (HOLES MUSTBE CUT TO INSTALL THE SOAP DISPENSERS BY G.C.)
2. THE G.C. SHALL RECEIVE SHOP DRAWINGS FROM THE OWNER'SMILLWORK VENDOR AFTER ARCHITECT'S REVIEW FOR USE INCOORDINATING BLOCKING, ROUGH OPENINGS, ETC. PRIOR TO THEINSTALLATION OF THE MILLWORK.
3. CONTRACTOR SHALL VERIFY THAT ALL COUNTERTOPS INCLUDINGDIALYSIS COUNTER TOPS ARE SECURELY MOUNTED TO THE WALL ORBASE FRAME.
4. CONTRACTOR SHALL PROVIDE 2X4 FRT BLOCKING FOR ALL WALLMOUNTED ITEMS.
5. MILLWORK RECEIVED FROM OWNER'S MILLWORK VENDOR WILL COME INPIECES, AND SHALL BE ASSEMBLED BY G.C. IN FIELD.
6. SEND RFI TO OWNER / ARCHITECT IF MILLWORK SHOP DRAWINGSDIFFER FROM A9 SERIES ELEVATIONS.
7. CONTRACTOR SHALL SEAL TOP OF MILLWORK TO WALLS,BACKSPLASHES AND COUNTER TOPS WITH CLEAR SILICONE CAULK.
2'-6
"M
AX
.
KNEE SPACE
15'-0"
2" GROMMET (TYP.)
PLASTIC LAMINATEDESKTOP, SCRIBED ANDSEALED TO WALL,PROVIDE REAR AND SIDECLEATS WITH BLOCKING INWALL AS REQUIRED
LOCKABLE SLIDINGTEMPERED GLASSTRANSACTION WINDOWIN RECESSED ALUMINUMTRACK TOP AND BOTTOM
BASE AS SCHEDULED
POWER AND DATAAT 18" A.F.F. (TYP.)
PLASTIC LAMINATETRANSACTIONCOUNTERS (TYP.)
ROLL-OUT KEYBOARDTRAY (TYP.)
METAL SUPPORTBRACKET (TYP.)
INSTALL P.LAM. HINGEDDOOR ON COFFEEWINDOW (PROVIDED BYOWNER'S MILLWORKVENDOR - I.B.C.)
4'-0" R.O.
VERIFY W/ OWNER'SMILLWORK VENDOR
2'-0" 2'-0"
POWER ANDDATA AT 18" A.F.F.
BASE ASSCHEDULED
PAPERSHRED(N.I.C.)
COPYMACHINE
(N.I.C.)
POWER AT 18" A.F.F.
W3624W3624LOCKABLE PLASTICLAMINATE CABINETSWITH WIRE PULLS (TYP.)
CONTRACTOR SHALLPROVIDE 2X4 FRTBLOCKING. SEE GENERALNOTE #4 THIS SHEET
5'-0
"2'
-0"
CLEAR SILICONECAULK (TYP.)
3'-6
"M
AX
.3'
-6"
3A6.1
1A6.1
3'-6
"
3'-10 1/2"
7'-0
"
126SCALE: 3/8" = 1'-0"SCALE / H.C. HANDWASH SINK3
SINK "P-3H"
OPEN
3'-0" 1'-8"
PTD
1" FILLER
2'-1
0"
3'-0" 2'-6"2'-6"
6"
3'-0
"
3'-6
"
COUNTER MOUNTED TV BY OWNERSCOMMUNICATIONS VENDOR - SEEELECTRICAL DRAWINGS
CENTRIFUGE(N.I.C.)
GFI RECEPTACLE AT48" A.F.F. LOCATEDON SIDE WALL
SURFACE MOUNTED GFIELECTRICAL RECEPTACLEINSIDE BASE CABINET FORELECTRIC EYE FAUCET (TYP.)
DIVIDER PANEL
CLEAR SILICONE CAULK (TYP.)
SENSOR CONTROLFAUCET (TYP.)
COUNTERTOP W/ BACKSPLASHAND SIDESPLASH
B30
DIRTY
BLANK
1" FILLER
2'-3" 1'-3" 1'-3" 2'-6" 2'-6" 1'-0"
1" FILLER
3'-0
"
3'-6
"
B30B27 DB15 DB15
PARTIAL HEIGHT PARTITION BYG.C. AND WALL CAPS BY OWNER'SMILLWORK VENDOR, I.B.C.
SENSOR CONTROL FAUCET (TYP.)
COUNTERTOP W/ BACKSPLASH
CLEAR SILICONE CAULK (TYP.)
BASE AS SCHEDULED
PARTIAL HEIGHT PARTITIONSAND WALL CAPS BY OWNER'SMILLWORK VENDOR, I.B.C.
DIVIDER PANELS (TYP.)
3'-0
"
LOCKABLE PLASTICLAMINATE CABINETS WITHWIRE PULLS (TYP.)
SURFACE MOUNTED GFIELEC. RECEPTACLE INSIDEBASE CABINET FORELECTRIC EYE FAUCET
4'-0
"
3'-6
"
ACOUSTIC CLOUD SOFFITABOVE - SEE SHEET A2.5
GLASS SPLASH PANEL (TYP.)
BLANK
4"2'
-6"
2'-6
"
REFRIG.(N.I.C.)
OPEN
MICROWAVE
W2815
PTD
COFFEE
W2830W2730 W2830 W2830
1" FILLER
2'-4" 2'-4" 2'-4" 1'-6" 3'-1" 3'-2 1/2"
B28
2'-1
0"1'
-9"
2'-5
"
B28 B28 DB18
134SCALE: 3/8" = 1'-0"HAND WASH SINK / DIRTY BLEACH SINK / CLEAN BLEACH SINK6
133132
137SCALE: 3/8" = 1'-0"CLEAN BLEACH SINK / DIRTY BLEACH SINK / HAND WASH SINK7
136135
PTD
PTD
3"
2'-6" 2'-6" 1'-5" 1'-4" 2'-8" 2'-8" 2'-6"
3"
CHASE FINISHED ON FOUR SIDESBY OWNER'S MILLWORK VENDOR,INSTALLED BY CONTRACTOR
B30
DIRTY
B30 B32 B32 B30B16
LOCKABLE PLASTIC LAMINATECABINETS WITH WIRE PULLS (TYP.)
SENSOR CONTROLFAUCET (TYP.)
COUNTERTOP W/BACKSPLASH
CLEAR SILICONECAULK (TYP.)
BASE ASSCHEDULED
PARTIAL HEIGHTPARTITIONS AND WALLCAPS BY OWNER'SMILLWORK VENDOR, I.B.C.
DIVIDER PANELS (TYP.)
3'-0
"
LOCKABLE PLASTICLAMINATE CABINETS WITHWIRE PULLS (TYP.)
SURFACE MOUNTED GFIELEC. RECEPTACLE INSIDEBASE CABINET FORELECTRIC EYE FAUCET
4'-0
"
3'-6
"
ACOUSTIC CLOUD SOFFITABOVE - SEE SHEET A2.5
GLASS SPLASH PANEL (TYP.)
BLANK
PTD
PTD
3"
2'-6"2'-6"1'-5"1'-4"2'-8"2'-8"2'-6"
3"
CHASE FINISHED ON FOURSIDES BY OWNER'SMILLWORK VENDOR,INSTALLED BY CONTRACTOR
B30
DIRTY
B30B32B32B30 B16
EMERGENCY EYE WASH SEEPLUMBING DRAWINGS FOR MOREINFORMATION. INSTALLATION SHALLNOT IMPEED FAUCET LOCATION.CAUTION - PROPER LOCATION MUSTBE DETERMIND BEFORE DRILLINGHOLE FOR EMERGENCY EYE WASH.
12A6.2
TRACK MOUNTINGBRACKET MOUNT TOWALL AND FLOOR(TYPICAL)
SLIDING DOORTRACK
TROLLEYASSEMBLY
HOOK RECEIVER
GATE HOOK
SINGLE CIPHERLOCK WITH ADAHARDWARE ONOPPOSITE SIDE
FLOOR/WALLMOUNTED POST
FLOOR/WALLMOUNTEDPOST
FLOOR MOUNTINGANGLE
FLOOR/WALLMOUNTED POST (3)
BOTTOM GUIDE
WALLMOUNTINGANGLE(3 PER POST, SUPPLIEDBY CONTRACTOR)
SLIDING DOORTRACK
5'-0" WIDESLIDING GATE
ELEVATION
OPENING INTOWATER
TREATMENTROOM
BOTTOM GUIDE
WALL MOUNTING ANGLE(3 PER POST, SUPPLIEDBY CONTRACTOR)
NOTES:1. WHEN ORDERING THE GATE KIT, THE 3 POSTS MUST
ALSO BE ORDERED, THEY ARE NOT INCLUDED WITHTHE GATE.
2. SEE SPEC SECTION 10605 FOR MORE INFORMATION.
PLAN
149SCALE: 3/8" = 1'-0"SLIDING WATER ROOM GATE9
SLOPED TOP BYOWNER'S MILLWORKVENDOR, I.B.C.
SLOPED TOP BYOWNER'S MILLWORKVENDOR, I.B.C.
SLOPED TOP BYOWNER'S MILLWORKVENDOR, I.B.C.
5'-0"
PROVIDE FRPCORNER TRIMSON ALL CORNERS
COUNTER TOP BYOWNER'S MILLWORKVENDOR, I.B.C.
5'-5
1/2"
#D
ATE
RE
VIS
ION
DE
SC
RIP
TIO
N---
A9.1
TMW
JLR
INTERIORELEVATIONS
AR
CH
ITE
CT
SE
NG
INE
ER
SP
LA
NN
ER
SCh
risto
pher
Kidd
and
Asso
ciat
es,
PC
N48
W16
550
Lisb
onR
oad
Men
omon
eeFa
lls,W
isco
nsin
5305
1-66
30P
262.
901.
0505
F26
2.90
1.05
10ar
ch@
cka-
ae.c
omck
a-ae
.com
Pro
pose
dE
SR
DFa
cilit
yfo
r:A
RA
Linc
oln
Park
Kid
ney
Cen
ter
1491
Sout
hfie
ldR
oad
Linc
oln
Par
k,M
I481
46
Drafted By:
Checked By:
Date Drafted:
Project #:
These drawings, as instrumentsof service, remain the propertyof the Architect or Engineer.Any changes, publication, oruse of any kind is prohibitedunless expressly authorized bysaid party.
Copyright 2016
16008-03
02-28-2017
MICHIGAN ARCHITECTURAL BUSINESSLICENSE NUMBER : 444650
Prepared by:Architect
Christopher D. Kidd, AIA, ALA, RIBAMichigan License # 1301042186Expires: October 31, 2017
Date of Review:
Seal:
A2
A2
02-2
8-20
17A
DD
EN
DU
M#2
MM
W
A4
A4
A4
03-1
3-20
17A
DD
EN
DU
M#4
MM
W