01327-I1013 Copyright © 2013 Micro Matic USA, Inc. All Rights Reserved. RSV/RPV Closed Systems Dispense Coupler - Maintenance Instructions 1 2 3 4 5 Remove dry break seal from probe and discard. Remove insert and discard. Remove spring from probe and discard. Remove main seal from coupler body and discard. Disassemble coupler by removing c-clips and clevis pins in order to replace O-ring seal. Note: This step and steps 6 and 7 in disassembly and steps 1, 7 and 8 in assembly do not apply to couplers with rivets. Disassembly Probe 6 7 Separate probe assembly from coupler body. Remove O-ring seal from coupler body and discard. Insert Spring

Upload: dangthuan

Post on 23-Feb-2019

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RSV/RPV Closed Systems - Beverage Dispensing · Dispense Coupler - Maintenance Instructions. Created Date: 10/2/2013 8:50:33 AM

01327-I1013 Copyright © 2013 Micro Matic USA, Inc. All Rights Reserved.

RSV/RPV Closed SystemsDispense Coupler - Maintenance Instructions

1 2 3

4 5

Remove dry break seal from probe and discard.

Remove insert and discard. Remove spring from probe and discard.

Remove main seal from coupler body and discard.

Disassemble coupler by removing c-clips and clevis pins in order to replace O-ring seal.Note: This step and steps 6 and 7 in disassembly and steps 1, 7 and 8 in assembly do not apply to couplers with rivets.

Disassembly

Probe

6 7

Separate probe assembly from coupler body.

Remove O-ring seal from coupler body and discard.

Insert

Spring

Page 2: RSV/RPV Closed Systems - Beverage Dispensing · Dispense Coupler - Maintenance Instructions. Created Date: 10/2/2013 8:50:33 AM

013267-I1013 Copyright © 2013 Micro Matic USA, Inc. All Rights Reserved.

1 2 3

DVC 2400 Viton Seal Kit. Install new O-ring seal into grove. Note: Lightly lubricate O-ring prior to installing with silicone grease or a lubricant that is compatible with the product. Take care not to spread the lubricant on other components.

Turn coupler body upside down.Clean main seal groove. Install new main seal.

Assembly

O-ring Main SealSpring Dry Break

Seal

InsertC - Clips

4 5

Install spring by placing the largest end of spring into the probe and wiggle in a clockwise direction while pressing down firmly.

Install new dry break seal on insert. Note: Seal must be secured over groove on insert for proper installation.

6

Place new dry break seal assembly on spring. Press the new dry break seal assembly firmly into the probe until the dry break seal locks into place.

Secured correctly

1 2

Secured correctly

Probe

7 8

Push probe assembly into coupler body. Slide lock arm into lock arm guide.

Place new dry break seal assembly on spring.

9

Lock armLock arm guide

Correctly assembled coupler.

RSV/RPV Closed SystemsDispense Coupler - Maintenance Instructions