rts100/r ts100r series total station vidalaser sas … · data trans fer so ftware foif geomatics...

2
Alphanumeric keyboard 128M(Extendable) internal memory, 120000 points and 40 Jobs can be saved 7 8 9 4 5 6 1 2 3 0 >12h Bluetooth cable-free connection(Factory Optional) Ò RTS100/RTS100R can connect to data collector through Bluetooth or RS-232C Can be operated with a data collector, FOIF FieldGenius, or other third party software is available SD SD 2GB Power long reflectorless measuring distance:300m(RTS100R3)/500m(RTS100R5) RTS100R3 EDM can be upgraded to RTS100R5 EDM(Factory Optional) IP66 environmental protection RTS100/RTS100R Series Total Station

Upload: trinhdan

Post on 26-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RTS100/R TS100R Series Total Station vidaLaser sas … · Data trans fer so ftware FOIF Geomatics Office Office processing sof tware FOIF Geomatics CAD(Optional) Data collecto r PS236,

Alphanumeric keyboard

128M(Extendable) internal memory, 120000 points and 40 Jobs can be saved

7 8 94 5 61 2 30 ¡¤¡À >12h

Bluetooth cable-free connection(Factory Optional)Ò

RTS100/RTS100R can connect to data collector through Bluetooth or RS-232C

Can be operated with a data collector, FOIF FieldGenius, or other third party software is available

SDSD2GB

Power long reflectorless measuring distance:300m(RTS100R3)/500m(RTS100R5)

RTS100R3 EDM can be upgraded to RTS100R5 EDM(Factory Optional)

IP66 environmental protection

RTS100/RTS100R Series

Total Station

WS1
vidaLaser sas V.le Rimembranze 43/b IT-20020 Lainate MI Tel. 029371038 Fax 0293570960 email [email protected]
Page 2: RTS100/R TS100R Series Total Station vidaLaser sas … · Data trans fer so ftware FOIF Geomatics Office Office processing sof tware FOIF Geomatics CAD(Optional) Data collecto r PS236,

Distance measurement

Length

Image

Objective aperture

Magnification

Field of view

Shortest focus distance 1.0m

Telescope

Accuracy

Image

Magnification /Field of view

Focus range

Erect

x3

LCD, 6lines X20characters(96 X160 dots)

Charger

Continuous operation time

FDJ6-LI (100V /240V )

Power

Battery 3400mAh Li-ion Rechargeable

Laser plummet(Standard)

Laser spot brightness

Laser wave length

Accuracy

Adjustable

635nm

Laser class Class 2/IEC60825-1

Application programs

RTS100R RTS100

Illustrations, descriptions and technical specifications are not binding and may change

156mm

Erect

x30

Accuracy 2 / 5

360 /400gon/6400mil, selectable

Angle measurement

Reading system

1 /5 /10 (or 0.2mgon/1mgon/2mgon)

Angle unit

Display resolution

Absolute encoder

Plate level vial

Circular level vial

30 /2mm

8 /2mm

Level vial sensitivity

Display

Technical data

7.4V DCOutput voltage

Water and dust protection IP66(IEC60529)

120000 points, support SD card(Optional)

USB/RS-232C/Bluetooth(Factory Optional)

Data collection/Stake out/Resection/REM/MLM

Alphanumerical key board, both sides

AREA/Point to line/Z coordinate/OFFset

175x178x340mm

-20 to +50

-40 to +70

5.1kg Weight(including batteries)

Operating temperature

Storage temperature

Interface

Memory

Dimensions(WxDxH)

Keyboard

Others

Suzhou FOIF Co.,Ltd.TEL:+86 512 65224904FAX:+86 512 65230619Http://www.foif.com.cnE-mail:[email protected]: 18 Tong Yuan Road, Suzhou 215006, P.R. China

Local Dealer:Since 1958

RTS100/RTS100R Series Total Station

CPU 32Bit

Data transfer software FOIF Geomatics Office

Office processing software FOIF Geomatics CAD(Optional)

Data collector PS236, fully rugged PDA(Optional)

*1

Range 3

Compensator Electronic dual-axis

Optical plummet(Factory Optional)

*3 Reflector: White side of Kodak Gray Card with 90% reflective

*1 Standard deviation based on ISO17123-3

Measurement range (Good condition )

Measuring time

Display resolution(m/inch selectable) 0.2mm/1mm

Pressure input range 500hPa to 1500hPa( 1hPa steps)

-40 to +60 (1 steps) Temperature input range

Prism constant correction -99.9mm to +99.9mm

Reflectorless

Reflective sheet/RP60 1 to 800m

1.5mm+2ppm

1 to 3000m Single prism 1 to 3000m

/

/

Laser class(IEC60825-1)

Reflectorless

Prism

/

/

Prism

*2

*3

Class 1

R3

R5

1 to 300m

1 to 500m

/

Accuracy

/

Initial:2s Initial:2s

/

/

/

/

/

/

Class 3R

Class 3R Reflective sheet/RP60

Reflective sheet/RP60 3mm+2ppm

1.5mm+2ppm

/

Reflectorless

R3 1-150m:3mm+2ppm

R5 1-200m:3mm+2ppm

/

/

/

Reflective sheet/RP60

Prism

Reflectorless

typ.1.0-1.5s

typ.1.5s

typ.1.5-5s, max. 20s

1.0-1.5s

/

*2 Good conditions: no haze, visibility about 40km, no heat shimmer, breeze

150m:5mm+3ppm

200m:5mm+3ppm

1mm/1.5m

0.8mm/1.5m

/4

0.5m to

Approx. 26 hours(At +20 )

Approx.4 hours

RTS100

/RTS100R

2014.0

6

Charging time(at +20 )

(Single distance measurement every 30 seconds)

Setting accuracy 1

*4

*4 Laser plummet mounted on the bottom of the vertical axis

RTS100R RTS100

WS1
vidaLaser sas V.le Rimembranze 43/b IT-20020 Lainate MI Tel. 029371038 Fax0293570960 email [email protected]