Catheter Working Length (140 cm)
Distal Shaft (2.36F – 2.6F) Exit Markers
Proximal Shaft O.D. (2.0F)
Transition ZoneRx Port
Hub
Ordering Information
8
117-1708J117-2008J117-2208J117-2508J117-2708J117-3008J117-3208J117-3508J117-3708J117-4008J117-4508J117-5008J
10
117-1710J117-2010J117-2210J117-2510J117-2710J117-3010J117-3210J117-3510J117-3710J117-4010J117-4510J117-5010J
12
117-1712J117-2012J117-2212J117-2512J117-2712J117-3012J117-3212J117-3512J117-3712J117-4012J117-4512J117-5012J
15
117-1715J117-2015J117-2215J117-2515J117-2715J117-3015J117-3215J117-3515J117-3715J117-4015J117-4515J117-5015J
18
117-1718J117-2018J117-2218J117-2518J117-2718J117-3018J117-3218J117-3518J117-3718J117-4018J117-4518J117-5018J
Balloon Working Length (mm)
1.752.02.252.52.753.03.253.53.754.04.55.0
Balloon Diameter (mm)
Pressure atm (kPa)Balloon Diameter (mm)
Compliance Chart
NOM*
RBP**RBP**
1.75
1.681.701.731.751.771.801.821.841.871.891.92
2.0
1.901.931.972.002.032.072.102.132.162.202.23
2.25 2.5
2.402.442.472.502.532.562.602.632.662.692.72
2.75
2.612.662.702.752.802.842.892.932.983.023.07
3.0
2.862.912.953.003.053.093.143.183.233.273.32
3.25
3.103.153.203.253.303.353.403.453.503.553.59
3.5
3.333.393.443.503.563.613.673.723.783.833.89
3.75
3.543.613.683.753.823.893.964.034.104.174.24
4.0
3.793.863.934.004.074.144.214.274.344.414.48
4.5
4.264.344.424.504.584.664.744.824.904.985.06
5.0
4.704.804.905.005.105.205.305.405.495.595.69
68101214161820222426
(608)(811)(1013)(1216)(1419)(1621)(1824)(2027)(2229)(2432)(2634
* Nominal Pressure. The nominal in vitro device specifications do not take into account any lesion resistance.* * Rated Burst Pressure. Do not exceed RBP
2.142.172.212.252.292.332.362.402.442.482.51
CORONARY BALLOON
True Controlled Compliance and Ultimate Crossability for a
Wide Spectrum of Vessels
Ultimate Crossability and Tip Entry Profile
True Controlled Compliance and Ultimate Crossability for a Wide Spectrum of Vessels
Sapphire II NC Coronary Dilatation Catheter is a well-balanced and truly non-compliant balloon catheter engineered to cross tight and calcified lesions.
True non-compliance and minimal overstretch for reliability and size accuracy. Sapphire NC brings advanced material engineering for optimum reliability and deliverability.
Crossing Profile Comparison
Data on file.
0.040
0.039
0.038
0.037
0.036
0.035
0.034
0.033
0.032
0.031NC Trek
0.0380
Hiryu
0.0373
Lifespear
0.0361
QuantumApex
0.0360
SapphireII NC
0.0336
Enhanced distal Z-Tip with advanced laser welding technology for “ZERO” transition with conventional steerable guidewires
True Controlled Compliance
Compliance Comparison from Nominal Pressure to RBP
10.0
8.0
6.0
4.0
1st 2nd 3rd 4th 5th
Sapphire I I NC (3.0x18 mm)
Gro
wth
Rat
e (%
)
Inflation cycles
Hiryu (3.0x15 mm)
Quantum Apex (3.0x15 mm)
NC Trek (3.0x15 mm)
Data on file.
“ZERO” transition between distal leading tip and conventional 0.014” guidewire
Lowest compliance growth rate at every inflation
Technical Specifications
Proximal Shaft
Distal Shaft
Catheter Working Length
Tip Length
Marker Bands
Coating
Nominal Pressure
Rated Burst Pressure
2.0F
140 cm
2
12 atm
20 atm (1.75 - 4.0 mm); 18 atm (4.5 - 5.0 mm)
1.5 mm tip for Ø 1.75 mm; 2.0 mm tip for Ø 2.0 - 3.0 mm2.5 mm tip for Ø 3.25 - 5.0 mm
Hydro-X (distal tip to guidewire exit port); InvioTM (guidewire lumen)
2.36F (1.75 - 2.0 mm); 2.55F (2.25 - 3.5 mm)2.6F (3.75 - 5.0 mm)
Special proprietary balloon processing resulting in superb crossing profile for primary and repeated lesion entry
(inch
)