schott nexterion® hisens optical coating for high sensitive microarray analysis
DESCRIPTION
The reflective layers on Nexterion® HiSens significantly enhance sensitivity and signal response. The characteristics of the reflective layers have been optimized for the fluorescent wavelengths most commonly used in microarray experiments, and will simultaneously improve the performance in both the Cy3™ and Cy5™ channels. The slide is produced according to industry standard slide dimensions and is available with SCHOTT’s standard high quality functional coatings for DNA and protein microarraying. This means that the Nexterion® HiSens Slide is fully compatible with all microarray printing technologies and most slide processing protocols, allowing customers a smooth transition from industry-standard transparent microarray slides.TRANSCRIPT
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
SCHOTT Nexterion®
The Microarray Substrate Company
SCHOTT HiSens Slides: A Cure for the SensitivityBlues – Achieve HigherSignals with Less Target
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Approaches to increase signal or sensitivity
Obvious options
• Selection of appropriate slide surface• Optimized handling to achieve optimal signal/background ratios• Increase the dye load per target molecule
More sophisticated options
• Increase the dye load by for instance dendrimer technology or nanoparticles• Use of scanners with low intrinsic background levels• Use of optical coatings on slides
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Nexterion® HiSens Slides
Ø Launched January 2006
Ø Innovative optical coating specifically
developed for microarray substrates
Ø Fully compatable with any attachement
chemistry and arraying hardware
Ø Unique coating developed using SCHOTT expertise in optical glass
technology
SCHOTT’s solution is a fluorescence enhancing slide coating
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
How does the optical coating work?1. Increase of excitation
⇒
Coating is optimized to give the maximum E-field field strength in the vicinity of the surface ⇒ strongest fluorescence excitation
Reflecting wave overlaps incoming wave
Thin-film dielectriccoating
Organiccoating
Standing wave pattern
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
2. Maximize reflection towards the detector
glass substrate(borofloat)
λex Fluorescence emission
Organiccoating
Thin-film dielectriccoatingglass substrate
(borofloat)
λex Fluorescence emission
Coating is optimized to give the maximum reflection towards the detector
How does the optical coating work?
Both effects together ⇒ theoretically 12-fold enhancement of slide performance
Spots with labeledDNA or oligos
within ~ 50 nm fluorescence is enhanced
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Benchmark study on Nexterion® HiSens E
Which improvements can be obtained with
Nexterion® HiSens E slides?
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Objectives of the study
• Signal intensity• Target concentrations used• Number of genes detectable• Data correlation
Comparing Slide E against Slide HiSens E against the following parameters:
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Slides Nexterion® Slide E, Nexterion® HiSens E
Slide Processing standard protocols
Probes 70mer oligos, human AROS V4 (1 plate) + control plate
Spotting QArray Mini (Genetix), SMP3 pins (ArrayIt)
Target Dye 3 labeled cDNA derived from human brain/liver total RNA,
Dye 5 labeled cDNA derived from human liver/brain total RNA
Hybridization 2h - 8h, Tecan Hyb station HS4800
Scanning Affymetrix 428 and Tecan LS400 reloaded
Analysis IconoClust (Clondiag)
Experimental Details
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Slide HiSens ESlide E
IntensityHiLo
AROSOligos
AROS ControlOligos
Higher Signals with Nexterion® HiSens E
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Comparison of Signal IntensityNexterion vs. Slide (Gain: 30 dB, Cy3)® Slide E HiSens E
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1AA
01
1AB
01
1AC
01
1AD
01
1AE
01
1AF0
1
1AG
01
1AH
01
1BA
01
1BB
01
1BC
01
1BD
01
1BE
01
1BF0
1
1BG
01
1BH
01
Oligo/Gene
Inte
nsity
Slide ESlide HiSens E
Higher Signals with Nexterion® HiSens E
Background
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Comparison of Signal IntensityNexterion vs. Slide (Gain: 30 dB, Cy3)® Slide E HiSens E
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1AA
01
1AB
01
1AC
01
1AD
01
1AE
01
1AF0
1
1AG
01
1AH
01
1BA
01
1BB
01
1BC
01
1BD
01
1BE
01
1BF0
1
1BG
01
1BH
01
Oligo/Gene
Inte
nsity
Slide ESlide HiSens E
More detectable signals with Nexterion® HiSens E
25-35 % additional low expressor genes (30 of 96 testet on this slide) are detectable with HiSens E only
Background
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
8 fold higher performance with Nexterion® HiSensE
0123456789
1011121314151617
1AA
01
1AB
01
1AC
01
1AD
01
1AE
01
1AF
01
1AG
01
1AH
01
1BA
01
1BB
01
1BC
01
1BD
01
1BE
01
1BF
01
1BG
01
1BH
01
Oligo/Gene
Fact
or
Signal Enhancement Factor Nexterion vs. (Gain: 30 dB, Cy3) ® Slide E Slide HiSens E
Mean
Signals on average amplified approx. 8-fold
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Ambion Inc.: Slide E versus HiSens E for miRNA arrays
miRNA fractions from lung and bladder were hybridized against printed oligos20µg totalRNA equivalents on Slide E on HiSens E
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
10 times less target and better signals!
20µg totalRNA equival. on E 2µg totalRNA equival. on HiSens E
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
• On average 7.8 fold increase of net signal• 50% more signals detectable
Quantification of signal-background1. median signal – local background 2. normalization to ratios of slide E
20 µg. eq Sum Intensity
0
10000
20000
30000
40000
50000
60000
70000
80000
90000
100000
Oligo
RFU
avg E avg HiSens
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
HiSens vs Slide EOptimized Scanning
-6
-4
-2
0
2
4
6
psID
Lo
g(b
as
e2
)R/G
0
10000
20000
30000
40000
50000
60000
70000
80000
SlideE 20ug avg SlideE 5ug avg SlideE 2 ug avg HiSens 20ug avg HiSens 5ug avg HiSens 2ug avg AVERAGE sum med. Int.
Correlation of Nexterion® HiSens E and Slide E data
Ø High data correlation between slide E and HiSens EØ High data correlation between different target concentrations
CorrelationSlideE 20 µg & Slide E 5 µg = 0.991834Slide E 20 µg & Slide E 2 µg = 0.958447Slide E 20 µg & HiSens 20 µg = 0.983246Slide E 20 µg & HiSens 5 µg = 0.969035Slide E 20 µg & HiSens 2 µg = 0.971587HiSens 20 µg & HiSens 5 µg = 0.990909HiSens 20 µg & HiSens 2 µg = 0.973892
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Dye swap experiments of Nexterion® HiSens E at City of Hope National Medical Center
Hu.Thymus 555Hu.Brain 647
Hu.Thymus 555Hu.Brain 647
miRNA array with Ambion‘s mirVana probes dissolved in low evaporation buffer
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Data correlation
F635 Median - B635200 2000 20000
F532
Med
ian
- B53
2
2000
20000
hsa_mir_205
hsa_mir_494
hsa_mir_124a
hsa_mir_26a
hsa_mir_16
ambi_mir_7029
F635 Median - B635200 2000 20000
F532
Med
ian
- B53
2
100
1000
10000 hsa_mir_205
hsa_mir_494
hsa_mir_124a
hsa_mir_26a
hsa_mir_16
ambi_mir_7029
Hu.Thymus 555Hu.Brain 647
Hu.Thymus 555Hu.Brain 647
Ø Data show excellent correlation with dye swap on HiSens E
Slide 31 Slide 30
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Different coatings and formats available....
MPX formatfor all functional coatings
MTP formatfor E and A chemistry
Nexterion® Slide EEpoxy chemistry
Nexterion® Slide AAmino chemistry
Nexterion® Slide A+Amino chemistry
Nexterion® Slide ALAldehyde chemistry
Nexterion® Slide HNHS-ester chemistry
Nexterion® HiSensfor E, A and H chemistry
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
Conclusions
• On average 8 fold higher net signals
• 3-4 fold increased signal/noise ratio
• Identification of weakly expressed genes
25%-50% more genes detectable!
• Less target/probe required
• Protocols identical to conventional slides
• Compatible with all microarray equipment (except
scanners that image through the rear face of the slide)
COMPANY PRESENTATION PRODUCT GROUP NEXTERION
SCHOTT Nexterion®
The Microarray Substrate Company
SCHOTT HiSens Slides: A Cure for the SensitivityBlues – Achieve HigherSignals with Less Target