scu - data connect enterprise adtran total access 1500 system controller unit scu is a com-mon...

2
The ADTRAN Total Access 1500 System Controller Unit SCU is a com- mon module plug-in unit that provides all control functions for the Total Access 1500 common units and all individual access modules. It is the log- ical and physical interface to the Total Access 1500 and is responsible for managing the craft interface port for provisioning of channel units. The SCU manages all network related functions and communicates externally through RS-232, RS-485, and Ethernet interfaces. The SCU also supervises the Mechanized Loop Test (MLT) feature and controls the activation/deac- tivation relays. The SCU monitors the T1 alarm information received from the LIU along with the status of the PSU/RG, and then determines the alarm state of the bank. A faceplate CRAFT DB-9 provides access for a VT100 terminal for screen menu provisioning. A momentary push-button switch is accessible through the faceplate, which controls alarm cutoff (ACO). Status indicators are also located on the front panel. The unit has T1 performance monitor- ing and test equipment timing output. It complies with NEBS Level 3 and UL 1950 standards. ADTRAN’s new Carrier Class multiservice access platform, Total Access 1500, offers unmatched versatility for narrowband service offerings in the smallest form factor available. The platform integrates the functionality of many different carrier products into a single chassis. It features high den- sity, easy provisioning, flexible deployment, and low cost-per-port. The Total Access 1500 can terminate up to five individual T1s, using copper or fiber facilities to provide diverse network routing and protection. Deployed in either the central office or remote terminal, the Total Access 1500 provides a fast, simple, and effective means of increasing POTS capac- ity, deploying special services, and deploying DSL services. PRODUCT FEATURES Controls all common equipment and access modules Mechanized Loop Test (MLT) capability Provides VT 100 craft interface via faceplate DB-9 connector Alarm cutoff (ACO) pushbutton LED network status indication T1 performance monitoring Test equipment timing output NEBS Level 3 and UL 1950 compliant SCU TOTAL ACCESS TM 1500 SCU

Upload: nguyenminh

Post on 27-May-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SCU - Data Connect Enterprise ADTRAN Total Access 1500 System Controller Unit SCU is a com-mon module plug-in unit that provides all control functions for the Total Access 1500 common

The ADTRAN Total Access 1500 System Controller Unit SCU is a com-mon module plug-in unit that provides all control functions for the TotalAccess 1500 common units and all individual access modules. It is the log-ical and physical interface to the Total Access 1500 and is responsible formanaging the craft interface port for provisioning of channel units. TheSCU manages all network related functions and communicates externallythrough RS-232, RS-485, and Ethernet interfaces. The SCU also supervisesthe Mechanized Loop Test (MLT) feature and controls the activation/deac-tivation relays. The SCU monitors the T1 alarm information received fromthe LIU along with the status of the PSU/RG, and then determines thealarm state of the bank.

A faceplate CRAFT DB-9 provides access for a VT100 terminal for screenmenu provisioning. A momentary push-button switch is accessiblethrough the faceplate, which controls alarm cutoff (ACO). Status indicatorsare also located on the front panel. The unit has T1 performance monitor-ing and test equipment timing output. It complies with NEBS Level 3 andUL 1950 standards.

ADTRAN’s new Carrier Class multiservice access platform, Total Access1500, offers unmatched versatility for narrowband service offerings in thesmallest form factor available. The platform integrates the functionality ofmany different carrier products into a single chassis. It features high den-sity, easy provisioning, flexible deployment, and low cost-per-port. TheTotal Access 1500 can terminate up to five individual T1s, using copper orfiber facilities to provide diverse network routing and protection.Deployed in either the central office or remote terminal, the Total Access1500 provides a fast, simple, and effective means of increasing POTS capac-ity, deploying special services, and deploying DSL services.

P R O D U C T F E A T U R E S

� Controls all common equipmentand access modules

� Mechanized Loop Test (MLT)capability

� Provides VT 100 craft interfacevia faceplate DB-9 connector

� Alarm cutoff (ACO) pushbutton

� LED network status indication

� T1 performance monitoring

� Test equipment timing output

� NEBS Level 3 and UL 1950 compliant

SCUT O TA L A C C E S S T M 1 5 0 0 S C U

Page 2: SCU - Data Connect Enterprise ADTRAN Total Access 1500 System Controller Unit SCU is a com-mon module plug-in unit that provides all control functions for the Total Access 1500 common

Product Specifications

MECHANICAL� Dimensions: 2.34" H, 0.70" W, 9.12" L� Weight: 2 lb� Mounting: Plugs into the SCU slot of the

Total Access 1500 chassis

FACEPLATE FEATURESLEDs� MJR: Red indicates major alarm active.� MNR: Red indicates minor alarm active.� RMT: Yellow indicates remote or auxiliary

alarm active.� ACO: Green indicates ACO switch

activated.� HST: Green indicates master RS485 unit.� MLT BSY: Green indicates MLT test active.� ACO pushbutton: Audible office alarm

cutoff.

CORPORATE OFFICEADTRAN, Inc.

901 Explorer BoulevardP.O. Box 140000

Huntsville, AL 35814-4000

800 9ADTRAN256 963-8000

fax: 256 963-7916fax back: 256 963-8200

e-mail: [email protected] site: www.adtran.com

REGIONAL OFFICES

Dallas, TX800 471-8648

Denver, CO800 471-8651

Irvine, CA800 788-5408

Kansas City, KS800 471-8649

Philadelphia, PA800 471-8656

San Antonio, TX888 223-7671

INTERNATIONAL CONTACTS

Asia Pacific-Hong Kong1 852 2824-8283 (Hong Kong)

Europe-Zurich, Switzerland41 1 880 27 77

Mexico/Caribbean1 954 577-0357

Latin America1 954 746-5355

Canada-Ontario1 905 474-5703

Canada-Quebec1 514 940-2888

All other inquiries1 256 963-2500

ADTRAN is an ISO 9001 registered company.

Printed in the U.S.A. on recycled paper.61180008Lx-8B September 2000

©2000 ADTRAN, Inc. All rights reserved.

ENVIRONMENTAL� Operating: –40° to +65°C� Storage: –40° to +85°C� Relative Humidity: Up to 95%, non-condensing

Ordering Information

EQUIPMENT PART #SCU (COT or RT)...................................1180008L1SCU COT w/MLT...................................1180008L2SCU RT w/MLT .....................................1180008L3

Specifications subject to change without notice.

Built-inPAD

FNID1245201L1

DS1

DSL

SF(GRN)

ESF(YEL)

B8ZS(YEL)

AMI(GRN)

LBK

LOC

REM

TX

RX

LBK

MON

RS232

RS CS TD RD CD TR RI/OH LOC REMTEST

ISU Express

LOOP PWR

SELECT TEST

12

34

5

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

HTU-C1181101L1

PWR

DSX

TST

LP1

LP2

ALM

QFC-C

DSX

PWR

DSX

DSX

TST

ALM

1181300L1

DSX

#2

#3

#4

#1

QFC-C

DSX

PWR

DSX

DSX

TST

ALM

1181300L1

DSX

#2

#3

#4

#1

QFC-C

DSX

PWR

DSX

DSX

TST

ALM

1181300L1

DSX

#2

#3

#4

#1

QFC-C

DSX

PWR

DSX

DSX

TST

ALM

1181300L1

DSX

#2

#3

#4

#1

HD-10 BRI Mux1181200L1

HD-10 BRI Mux1181200L1

HD-10 BRI MuxPOWER

DSX

LBK

1181200L1HD-10 BRI MuxPOWER

DSX

LBK

1181200L1HD-10 BRI Mux

LBK

1181200L1 T1-ORPWR

DSX

LBK

LP

ALM

T

X

R

X6V

+

1181310L1T1-ORPWR

DSX

LBK

LP

ALM

T

X

R

X6V

+

1181310L1T1-ORPWR

DSX

LBK

LP

ALM

T

X

R

X6V

+

1181310L1T1-ORPWR

DSX

LBK

LP

ALM

T

X

R

X6V

+

1181310L1HTU-C

1181101L1

PWR

DSX

TST

LP1

LP2

ALM