seap + enms implementation and monitoring in the latvian ...€¦ · jan feb mar apr mai jūn jūl...
TRANSCRIPT
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
SEAP + EnMS implementation and
monitoring in the Latvian municipalities
Current achievements and experience
Marika Rošā, Ekodoma
3rd centralised training session in Lyon
19 November 2015
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 2
EXPERIENCE BEFORE
50000&1SEAPs IN LATVIA
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 3
CURRENTLY BETTER KNOWN ENERGY
MANAGEMENT MODELS IN LATVIAN
MUNICIPALITIES
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 4
ENERGY MANAGEMENT IN PUBLIC BUILDINGS. VENTSPILS
Norenovēja visas pašvaldības ēkas
Katrai ēkai uzlikts uzdevums sasniegt plānoto enerģijas ietaupījumu
&mikroklimatu
Dome nodrošināja atbalstu
Atbild par 7 ēkām
• Iepērk (trīspusējs
līgums)
Atskaite
Atskaite
Atskaite
AtskaiteAtskaite
Ventspils dome
Izglītības pārvalde Ventspils nekustamie īpašumi
Ikmēneša „izej cauri” energoaudits
katrā ēkā (viena atskaite)
Pašvaldības
ēka 1
Pašvaldības
ēka 2
Pašvaldības
ēka n
Ikmēneša „izej cauri”
energoaudits
Monthly walk through energy audits include temperature and CO2measurements, assessment of radiators, windows, ventilation;
assessment of heat consumption; monitoring reports
Atbild par 22 ēkām
• Iepērk (līgums)
USE OUTSOURCING
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
2006 2007 2008 2009 2010
Reduction
55%
Achievments: from 1.6 GWh/month in 2006 to 0.9 GWh/month in 2013
MEASUREMENTS AND MONITORING
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 6
ENERGY MANAGEMENT IN PUBLIC BUILDINGS. LIEPĀJA
Norenovēja visas pašvaldības ēkas
Katrai renovētajai ēkai (KPFI) uzlikts uzdevums
sasniegt plānoto enerģijas ietaupījumu &mikroklimatu
Dome nodrošināja atbalstu
Tehniskā palīdzība, apmācība, mikroklimata kontrole
Enerģijas patēriņa dati
LIEPĀJAS PILSĒTAS DOME
Pašvaldības ēka Nr.2
Pašvaldības ēka Nr.1
Pašvaldības ēka Nr.3
Pašvaldības ēka Nr….
Pašvaldības ēka Nr.n
Izpilddirektora vietnieks nekustamā īpašuma jautājumos
RESPONSABILITY IN
THE COUNCIL
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
HOW DATA ARE
SUMMARISED IN LIEPĀJA
Source: Mārtiņš Tīdens, city of Liepāja
0,00
5,00
10,00
15,00
20,00
25,00
30,00
35,00
jan feb mar apr mai jūn jūl aug sep okt nov dec
Vidējais patēriņš pēdējos 4 gados MWh
Patēriņš gadā MWh 2011
Patēriņš gadā MWh 2012
Patēriņš gadā MWh 2013
Patēriņš gadā MWh 2014
Patēriņš gadā MWh 2015
Patēriņš gadā MWh 2016
• Heat consumption• Economy• Air quality/microclimate
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 8
DURING 50000&1SEAPs IN
LATVIA…
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 9
HOW ENERGY MANAGEMENT IS TREATED
IN LATVIA?
Draft Energy Efficiency Law (approved in the first
round in Parliament on 26 May 2015)
Article 7 foresees:
• (2) The major cities introduce and certify energy management system in
their municipalities according to LVS EN ISO 50001:2012 standard
• (3) Regional municipalities with development index above 0.5 and population
above 10000, introduce energy management system in their municipalities
according to LVS EN ISO 50001:2012 standard
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 10
municipalities of
50000&1SEAPs
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 11
Municipality Population Area, km2 Units
Daugavpils 101 057 72.48 City
Cēsis 18 065 171.7City and 1
parish
Smiltene 14 531 949City and 8
parishes
Sigulda 11 650 360.9City and 3
parishes
Ādaži 10 750 162.9Main centre
and other units
OUR FIVE MUNICIPALITIES – HOW DO THEY
LOOK LIKE?
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 12
TWO APPROACHES USED
Energy audits SEAP EMS
EMS
SEAP
1
2
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 13
FIRST APPROACH
Case of municipality of Ādaži
(population of 10 000)
Energy audits SEAP EMS
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 14
MAIN ENERGY SOURCES IN ĀDAŽI
Baseline of SEAP
Energy review of EMS (2014)
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 15
BOUNDARIES OF THE EMS IN ĀDAŽI
Six public buildings+
Public street lighting
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
EXISTING (ENERGY)MANAGEMENT SYSTEM IN
MUNICIPALITY OF ĀDAŽI
Municipal buildings
Technical department
Council/Accounting department
Contract
Boiler management company
Electricity supplierLatvian gas/liquid fuel
supplier
Produced heat energy (only in Ādaži secondary
school)
Consumption
Bill of endorsement
€
Bill
Meter readings
€
Bill
Street lighting management company
Meter readings
Contract
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
PROPOSED ENERGY MANAGEMENT RESPONSABILITIES
IN ĀDAŽI
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 18
SECOND APPROACH
Case of city of Daugavpils
(population of 100 000)
EMS
SEAP
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 19
SPECIFIC HEAT CONSUMPTION IN PUBLIC BUILDINGS IN
DAUGAVPILS IN 2013 AND 2014
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
ENERGY CONSUMPTION IN PUBLIC BUILDINGS
Average electricitycosts during the last 3 years –
1..98 m€/year
Average heat costs during the last 3 years
–1.93 m€/year
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 21
• 98 buildingsPublic
buildings
• 150 metersPublic lighting
• Busses, trams and minibuses
Public transport
BOUNDARIES OF THE EMS IN DAUGAVPILS
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
(ENERGY)
MANAGEMENT IN
DAUGAVPILS
98 municipal buildings:
• Largest share – educational
buildings
38 municipal capital
buildings
Heat energy data («Daugavpils siltumtīkli»)
Electricity data («Sadales tīkls»)
Fuel consumption data (accounting)
Municipal buildingsThe City Council €
Me
ter
rea
din
gs
an
d €
Bil
ls
Consumption
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
PROPOSED ENERGY
MANAGEMENT IN
DAUGAVPILS
Reorganisation
needed;
Responsible for
EMS –
department of
Real estate
management
Heat energy data («Daugavpils siltumtīkli»)
Electricity data («Sadales tīkls»)
Fuel consumption data (accounting)
Municipal buildings
The Property department
The City Council €
Me
ter
rea
din
gs
an
d
€
Bil
ls
Consumption
Energy data Instruction
SEAP work group
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 24
WHAT NEXT?
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
1. EMS MONITORING TOOL FOR PUBLIC BUILDINGS
• Heat consumption
(need to be metered),
MWh (in case of DH)
• Fuel consumption,
thous.m3; t
• Heated area
• Outside temperature
• Electricity
consumption, MWh
• Fuel consumption for
transport, liters
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
• Monthly
electricity
consumption,
MWh
• Operational
hours
• Street lengths
and width
2. EMS MONITORING TOOL FOR PUBLIC LIGHTING
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs
• Monthly fuel
consumption, liters
• Number of passengers
• Distance travelled, km
3. EMS MONITORING TOOL FOR PUBLIC TRANSPORT
-
Supporting Local Authoritites in the Development and Integration of SEAPs with
Energy management SystemsAccording to ISO 500001www.500001seaps.eu
@500001SEAPs 28
THANK YOU!