Sequence Automation
2
In This Section, We Will Discuss:
How to set up a sequence.
How to perform automated recalibrations.
How to do bracketing.
How data files are named.
How to use Sequence Summary.
How to run the sequence.
The sequence container (folder).
3
Building a Sequence for Automated Analysis
1. Go to the Method and Run Control view.
2. Go to View > Preferences and set up sequence folder naming convention.
3. From the Sequence menu, select New Sequence.
3. Edit the Sequence Parameters.
4. Edit the Sequence Table.
5. Select a Sequence Output.
6. Save the Sequence
7. Run the Sequence form the RunControl menu or the Sequence Table.
Note: Hypersequence is a feature for the Agilent 1100/1200Series Well plate Handler only.
4
Preferences
•Specifies naming convention for sequence data containers.
5
Sequence Parameters
6
Explicit Calibration
CalibStandards
CalibStandards
CalibStandards
UpdateCalibration
UpdateCalibration
UpdateCalibration
Samples Samples
CalculateSample
AmountsAfter EachInjection
CalculateSample
AmountsAfter EachInjection
7
Sequence Table Explicit Recalibration
Additional Columns inSequence Tables:
•Sample Amount•ISTD Amount•Multiplier•Dilution •Data file•Inj Volume•Lims ID•AutoBalance
8
Customize Sequence Table
9
Explicit Plus Cyclic Recalibration
10
Bracketing Calibration
CalibStandards
CalibStandards
CalibStandardsSamples Samples
UpdateCalibration
CalculateSample
AmountsFor EachInjection
Injection
UpdateCalibration
CalculateSample
AmountsFor EachInjection
11
Bracketed Sequence Operation
12
Partial Sequence Preview of Bracketing
Will show you the order of injections.
13
Fill in Sequence Table Using Sequence Table Fill Down Wizard
14
Sequence Output
A Sequence Summary Reportallows you to select from asimple one page Sample Summary to a comprehensivereport documenting all aspectsof the analysis including cross-sample statistics.
15
Edit Sequence Summary
Statistics calculated inStandard or Extendedformat.
16
Extended Statistics
17
Save the Sequence File
Save Current Sequence
18
Sequence Sampling Diagram
Shows sequence tray set-up and sequence processing status. Click to set-up sequence. Select Start tobegin sequence.
Select from the View menu.
19
Start a Sequence
•RunControl menu•Start button•F6•Sequence Table•Partial Sequence Table
•When you start a sequence, a sequence folder is created in the DATA directory.
•The sequence folder is named according to the subdirectory specified in Sequence Parameters, and the naming convention specified in Preferences.
•A copy of the master methods (Chem32\1\Methods\names.M) and sequence template file (Chem32\1\Sequences\name.S) are copied to the folder. The sequence acquisition is run from these copies.
20
Sequence Folder Data Structure
Sequence Container (Folder)Subdirectory sequencetemplatename year-month-day hour-minute-second
C:\Chem32\1\DATA\03-15-06\CLASSSEQUENCE 2006-03-15 10-46-09
Copy of Sequence Template
Copy of Master Method
Acquired Data
Batch file for Batch Review
Sequence Logbook
21
Sequence Data Files
Format for Automatic Injection: 003-0101003 Vial Number01 Sequence Line01 Replicate
PrefixPrefix000001Prefix000002, etc. for a total of 15 characters
Format for a Cyclic Calibration Standard: C1-02001C Indicates a cyclic calibration standard was used1 Calib Line number02 Sequence Line001 Replicate
22
Recalibration Settings
23
Calibration Report Options