service luna platinum ed 8
TRANSCRIPT
-
8/10/2019 SERVICE Luna Platinum Ed 8
1/42
PCB
PARAMETRIZATION
Instructions for SERVICE
UPDATES:
20/08/2012 2edition PCB sof tware version V3.5.0-89 or higher
-
8/10/2019 SERVICE Luna Platinum Ed 8
2/42
CONTENTS
1 CONTROL PANEL MENU.................................................................................................................................... 3
1.1 ENGINEERMENU.......................................................... ........................................................... ....................... 3
2 PARAMETER LIST................................................................................................................................................ 4
3 ERROR LIST......................................................................................................................................................... 28
4 GAS ADAPTIVE SYSTEM.................................................. ........................................................... ..................... 33
5
FAULT FINDING......................................................... ........................................................... ............................... 34
6 BURNER PHASE (FAULT HISTORY)............................................................................................................. . 54
-
8/10/2019 SERVICE Luna Platinum Ed 8
3/42
1 CONTROL PANEL MENU
The following procedure is used to access the four boiler pro- gramming menus:
from the main menu C; A e C for approx. 6 seconds; B to see menus 1 - 2 - 3 - 4; B to confirm the selected menu; C to go back one menu at a time to the main menu.
The four menus are:
1 ENDUSER (visible pressing the button C)2 COMMISSIONING (visible with a buttons combination)3 ENGINEER (visible only with PASSWORD 10101)
4 OEM (visible only with PASSWORD)
1.1 ENGINEER menu
Access Engineermenu as described in section 1.This level includes all parameters present on Enduser and Commissioning menus.The details of this menu are given in next section.Some menus are avaible only if the system is correctly configured (e.g. solar menu).The parameters with grey underlight are different default values depending on boilermodel.
-
8/10/2019 SERVICE Luna Platinum Ed 8
4/42
2 PARAMETER LISTParameter Level INFORMATION
1 Room temperature Displayed if the control panel is configured as room unit
1 Room temperature min Displayed if the control panel is configured as room unit
1 Room temperature max Displayed if the control panel is configured as room unit
1 Boiler temperature
1 Outside temp
1 Outside temp min
1 Outside temp max
1 Instant HW heater temp
1 State central heating CH1
1 State central heating CH2 Displayed if the heating circuit is activated
1 State central heating CH3 Displayed if the heating circuit is activated
1 State hot water
1 State boiler
1 State SithermPro Only with LMS15 pcb
1 Telephone customer service
Parameter Level SET TIME AND DATE1 1 Hours / minutes
2 1 Day / month
3 1 Year
5 3 Start of summertime
6 3 End of summertime
Parameter Level OPERATOR SECTION20 1 Change Language
24 2 LightingOffTemporarilyPermanently
26 3 Operation lockOnOff
Block of the control panel buttons A e B
27 1 Programming lockOnOff
The parameters can be displayed but not cha
29 2 Units1 C , bar2 F , PSI
40 2 Used as
Operator unit 1Room unit 1Room unit 2Room unit 3
The control panel is installed in the boilerThe control panel is configured as room unit oThe control panel is configured as room unit oThe control panel is configured as room unit o
42 2 Assignment device 1
Temps / mode CH1Central heating 1 and 2
Central Heating 1 and 3All central heatings
As room unit 1, the action of the respective co
circuit 1 or to 2 heating circuits.
43 2 Action operation0 Locally1 Centrally
The room unit controls only the respective heOnly room unit 1 can be Centrally. It also con
54 2 Readjustment room sensor -3C+3C
70 2 Software version
Parameter Level WIRELESS 120 2 Binding Activation of wireless link with basic unit
121 2 Test mode Test mode is used for checking the wireless communication
130 2 Room unit 1 Check of link
-
8/10/2019 SERVICE Luna Platinum Ed 8
5/42
131 2 Room unit 2 Check of link
132 2 Room unit 3 Check of link
133 2 Outside sensor Check of link
134 2 Repeater Check of link
135 2 Operator unit Check of link
140 2 Delete all devices
Parameter Level TIME CENTRAL HEATING 1 2 31 2 3
1 Select days Selection of days or groups of days for time program500 520 540
514 534 554 1 Select default timings? Is it possibile to select up to 3 preselect time programs
501 521 541 1 1st Time ON502 522 542 1 1st Time OFF
503 523 543 1 2nd Time ON
504 524 544 1 2nd Time OFF
505 525 545 1 3rd Time ON
506 526 546 1 3rd Time OFF
516 536 556 1 Default valuesYesNo
Parameter Level TIME HOT WATER 560 1 Select days Selection of days or groups of days for time program
574 1 Select default timings? Is it possibile to select up to 3 preselect time programs
561 1 1st Time ON
562 1 1st Time OFF
563 1 2nd Time ON
564 1 2nd Time OFF
565 1 3rd Time ON566 1 3rd Time OFF
576 1 Default valuesYesNo
Parameter Level TIME AUXILIARY 600 1 Select days Selection of days or groups of days for time program
614 1 Select default timings? Is it possibile to select up to 3 preselect time programs
601 1 1st Time ON
602 1 1st Time OFF
603 1 2nd Time ON
604 1 2nd Time OFF
605 1 3rd Time ON
606 1 3rd Time OFF
616 1 Default valuesYesNo
Parameter Level HOLIDAY HEATING 1 2 31 2 31 Select Is it possibile to select up to 8 holiday periods
641 651 661
642 652 662 1 Start Day and month of holiday start
643 653 663 1 End Day and month of holiday end
648 658 668 1 Operating levelOffReduced
-
8/10/2019 SERVICE Luna Platinum Ed 8
6/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
7/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
8/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
9/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
10/42
2463 3 Settling time HW Validity time of parameter 2462
2670 3 ParameterActivation of Super Over Temperature Function (SOT):OnOff
2672 3 Parameter Increase of boiler setpoint for the control of SOT
2675 3 Parameter
2681 3 Parameter Precirculation time on DHW way (3WV position) during precirculation function
2682 3 Parameter Precirculation time on CH way (3WV position) during precirculation function
Parameter Level SITHERM PRO2700 3 Ion current filtered Ionization current actual value
2702 3 Position stepper motor Gas valve stepper motor position2703 3 Learning value gas quality Gas calorific power measurement
2706 3 Operating phase
2720 2 Release sel type of gasRelease of ga type selection:0 Off1 On
2721 2 Type of gasType of gas:1 Natural gas2 Liquefied gas
2725 3 Sel individual boiler setting
Activation of combustion adjustment:
OffSet low-fire ion currentSave low-fire ion currentSet high-fire ion currentSave high-fire ion current
Activation of correction at low powerStored of correction at low power
Activation of correction at high powerStored of correction at high power
2726 3 Ind boil setting ion curr LF Setting of correction at low power2729 3 Ind boil setting ion curr HF Setting of correction at high power
2740 3 Triggering drift test
Manual test of combustion adjustment:
01234
DisabledTest done at high and low powerTest done only at high powerTest done only at low powerTest done at high and low power alternativ
2741 3 Parameter Last test result at low power
2742 3 Parameter Last test filtred result at low power
2743 3 Parameter Correction at low power
2744 3 Parameter Threshold of correction at low power
2745 3 Parameter Last test result at high power
2746 3 Parameter Last test filtred result at high power
2747 3 Parameter Correction at high power2748 3 Parameter Threshold of correction at high power
2749 3 Reset drift test Reset of correction results
Parameter Level CASCADE
3510 3 Lead strategy Lead strategy:
-
8/10/2019 SERVICE Luna Platinum Ed 8
11/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
12/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
13/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
14/42
5040 3 Discharging protection
Attivazione della pompa Q3 in caso di temperatura di mandata troppo alta This fpump (Q3) is activated only when the heat source temperature is high enough:
OffAlwaysTimed
DisabledEnabled
Active only if the heat source is not able to
5050 3 Charging temp max Maximum charging temperature from solar collector
5051 3 Storage tank temp max Maximum hot water tank temperature
5055 3 Recooling temp Recooling hot water tank temperature
5056 3 Recooling heat gen/CHsTank recooling through heating circuit:On
Off
5057 3 Recooling collector
Tank recooling through solar collector:OffSummer
Always
5060 3 El imm heater optg mode
Electric immersion heater used for DHW tank:
Substitute
Summer
Always
The electric immersion heater is only usedmessage or has been shut down via boilerThe electric immersion heater is used wheswitched to summer operation. The DHW at least one of the heating circuits has swielectric immersion heater is also used if thor has been shut down via boiler lock.DHW is always heated with the electric im
5061 3 El immersion heater release
Electric immersion heater release:24h/day
Hot water releaseTime hot water
5062 3 El immersion heater controlElectric immersion heater control mode:External thermostatHot water sensor
5070 3 Hot water boostIf the DHW temperature drops by more than 2 switching differentials (l5024) belOnOff
5071 3 Charging prio time push The DHW storage tank is charged with absolute priority during the set period of
5085 3 Excess heat drawSurplus heat can be fed to the DHW storage tank:OnOff
5090 3 With bufferDHW storage tank receives its heat via buffer storage tank:YesNo
5092 3 With prim contr/system pump
DHW storage tank receives its heat via the primary controller or withthe help of the system pump:YesNo
5093 3 With solar integrationDHW storage tank receives its heat from the solar collectors:YesNo
Parameter Level INSTANTANEOUS HW HEATER
-
8/10/2019 SERVICE Luna Platinum Ed 8
15/42
5464 2 Hot water preheat release
Preheat mode:24h/dayHot water releaseTime central heating CH3Time hot waterTime auxiliary
5470 1 HW preheat time when no CH Preheat time
5476 3 Keep hot periodically Duration time of preheat function
5482 3 Flow switch time cons Minimum response time of the flow switch for detecting consumption
5490 3 Parameter
5491 3 Parameter
Parameter Level CONFIGURATION
5710 2 Temps / mode CH1Heating circuit 1 activation:0 Off1 On
5711 3 Cooling circuit 1Cooling circuit 1 activation:Off4-pipe system cooling
5715 2 Temps / mode CH2Heating circuit 2 activation:0 Off1 On
5721 2 Temps / mode CH3Heating circuit 3 activation:OffOn
5730 2 Hot water sensor
DHW sensor selection:
1 Hot water sensor B32 Thermostat3 HW outlet sensor B38
DHW storage tank sensorSensor used as DHW thermostatInstantaneous water heater outlet sensor
5731 2 HW controlling element
Actuator type for DHW request control:
No charging requestCharging pumpDiverting valve
No functionActuator used as charging pumpActuator used as diverting valve
5732 3 Pump off change div valve Set the time the pumps are deactivated when the diverting valve switches over
5733 3 Delay pump off Set the delay time for the pumps to be deactivated after the diverting valve has
5734 3 Basic pos HW div valve
Default DHW diverting valve position:
Last requestCentral heatingHot water
Default for boiler with DHW tankDefault for instantaneous water heater boi
5736 3 Hot water separate circuitThe DHW separate circuit can only be employed in a cascaded system:On
Off
5737 3 Optg action HW div valveThe diverting valve position selected here is the position used when the output iPosition on HWPosition on CH
5738 3 Midposition DHW div valveDHW diverting valve can be driven to the mid-position:OnOff
5774 3 Ctrl boiler pump/HW valveActivation mode of boiler pump and DHW diverting valve:All requestsRequest CH1/HW only
-
8/10/2019 SERVICE Luna Platinum Ed 8
16/42
5840 3 Solar controlling elementActuator configuration in case of solar storage tanks:
Charging pumpDiverting valve
Used as charging pumpUsed as diverting valve
5841 3 External solar exchanger
In the case of solar plant diagrams with 2 storage tanks, it must be selected wheexchanger for both the DHW and the buffer storage tank or for only one of themCommonlyHot water storage tankBuffer storage tank
5870 3 Combi storage tank
Functions specific to combi storage tanks are activated via this setting (for examinstalled in the buffer storage tank can be used for both space heating and DHW
YesNo
5890 2 Relay output QX1
0 None1 Circulating pump Q42 El imm heater HW K63 Collector pump Q54 Cons circuit pump VK1 Q155 Boiler pump Q16 Bypass pump Q127 Alarm output K108 2nd pump speed CH1 Q219 2nd pump speed CH2 Q2210 2nd pump speed CH3 Q2311 heating pump CH3 Q2012 Cons circuit pump VK2 Q1813 System pump Q1414 Heat gen shutoff valve Y415 Solid fuel boiler pump Q1016 Time setting 5 K1317 Buffer return valve Y1518 Solar pump ext exch K919 Solar ctrl elem buffer K820 Solar ctrl elem swi pool K1822 Swimming pool pump Q1925 Cascade pump Q2526 St tank transfer pump Q1127 Hot water mixing pump Q3528 HW interm circ pump Q3329 Heat request K2730 Refrigeration request K2833 Heating pump CH1 Q234 Heating pump CH2 Q635 Hot water ctrl elem Q336 Instant WH ctrl elem Q3438 Water refill K3439 2nd boiler pump speed Q2740 Status output K3541 Status information K3642 Flue gas damper K3743 Fan shutdown K38
DHW circulating pump
Solar collector pumpConsumer circuit 1 pumpBoiler pump
Alarm relay signals faults
Pump/zone valve for heating circuit 3
Pump activated at every heat request from
Solid flue boiler pumpThe relay is controlled according to setting
Contact to heat swimming pool by solar (in
Common cascade pump
Cooling request from cooling circuit 1Pump/zone valve for heating circuit 1Pump/zone valve for heating circuit 2Pump/diverting valve for DHW tankPump/diverting valve for instantaneous DHWater refill electrovalve2nd boiler pump speed
External fan control
5891 3 Relay output QX2 See relay output QX1
5892 3 Relay output QX3 See relay output QX1
-
8/10/2019 SERVICE Luna Platinum Ed 8
17/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
18/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
19/42
6051 2 Voltage value 2 H2 module 1 Parameter for characteristic definition of sensor
6052 2 Funct value 2 H2 module 1 Parameter for characteristic definition of sensor
6054 2 Function input H2 module 2 See function input H1
6055 2 Contact type H2 module 2NONC
6057 2 Voltage value 1 H2 module 2 Parameter for characteristic definition of sensor
6058 2 Funct value 1 H2 module 2 Parameter for characteristic definition of sensor
6059 2 Voltage value 2 H2 module 2 Parameter for characteristic definition of sensor
6060 2 Funct value 2 H2 module 2 Parameter for characteristic definition of sensor
6062 2 Function input H2 module 3 See function input H1
6063 2 Contact type H2 module 3 NONC
6065 2 Voltage value 1 H2 module 3 Parameter for characteristic definition of sensor
6066 2 Funct value 1 H2 module 3 Parameter for characteristic definition of sensor
6067 2 Voltage value 2 H2 module 3 Parameter for characteristic definition of sensor
6068 2 Funct value 2 H2 module 3 Parameter for characteristic definition of sensor
6097 2 Sensor type collectorSolar collector sensor type:1 NTC2 PT1000
6098 3 Readjustm collector sensor Correction of readed collector sensor value
6100 2 Readjustm outside sensor Correction of readed outside sensor value
6110 3 Time constant building Time thermic constant building
6120 3 System frost protectionPlant frost protection (only with outside sensor):OnOff
6200 2 Save sensors Stored of sensor used in plant
6205 3 Reset to default parameters Not used
6212 2 Check no. heat source 1 Manufactoring information
6213 2 Check no. heat source 2 Manufactoring information
6215 2 Check no. storage tank Manufactoring information
6217 2 Check no. heating circuits Manufactoring information
6220 3 Software version Manufactoring information
6230 2 Info 1 OEM Manufactoring information
6231 2 Info 2 OEM Manufactoring information
Parameter Level LPB SYSTEM
6600 3 Device address Choice of cascade device address from 1 to 16 (1 = master)
6601 3 Segment address Choice of cascade segment from 0 to 14
6604 3 Bus power supply functionBus power supply type:OffTimed
6605 3 Bus power supply stateBus power supply state:OnOff
6610 3 Display system messagesVisualization of system messages:YesNo
6612 3 Alarm delay Alarm time delay
6620 3 Action changeover functionsAction function changeover:SystemSegment
-
8/10/2019 SERVICE Luna Platinum Ed 8
20/42
6621 3 Summer changeoverSummer changeover:LocallyCentrally
6623 3 Optg mode changeoverOption mode changeover:LocallyCentrally
6624 3 Manual source lockLock mode:LocallySegment
6625 3 Hot water assignment
DHW assignment:
Local CHsAll CHs in segmentAll CHs in system
DHW used the setting of boilerDHW used the setting of boiler in same caDHW used the setting of boiler in cascade
6630 3 Cascade master
Cascade master:
AlwaysAutomatically
Cascade master is the boiler also if addresCascade master is the boiler with address
6631 3 Ext source with eco mode
In ECO mode, external heat sources on the LPB are operated as follows:OffOn hot waterOn
6632 3 Note OT limit ext sourceExternal heat sources can be locked or released according to their own parameYesNo
6640 3 Clock mode
Clock mode:
AutonomouslySlave without remote setting
Slave with remote settingMaster
Every boiler has own time programSlave boilers not use the master time prog
Slave boilers use the master time programThe master time program is used
6650 3 Outside temp sourceBoiler address where is connected outside sensor:- - . - - no outside sensor connectedThe first 2 numbers are hte segment number, the second part is the boiler numb
Parameter Level FAULT
6704 2 Display SW diagnostic codeVisualization of diagnostic code:0 No1 Yes
6705 1 SW diagnostic code Diagnostic code currently pending
6706 1 Burn ctrl phase lockout pos Lockout phase indicating where the fault occured
6710 2 Reset alarm relay Reset of alarm relay
6740 3 Flow temp 1 alarm value displayed
6741 3 Flow temp 2 alarm value displayed
6742 3 Flow temp 3 alarm value displayed6743 3 Boiler temp alarm value displayed
6745 3 Hot water charging alarm value displayed
6800 2 History 1 Last fault occured
6805 2 SW diagnostic code 1 Diagnostic code of last fault occured
6806 2 Burner control phase 1 Lockout phase indicating where the last fault occured
6810 - 6996 2 History from 2 to 20 Previous fault history
Parameter Level SERVICE/SPECIAL OPERATION
7040 3 Burner hours interval Burner hours before boiler maintenance
-
8/10/2019 SERVICE Luna Platinum Ed 8
21/42
7041 3 Burn hrs since maintenance Burner hours reset after boiler maintenance
7042 3 Burner start interval Burner ignition number before boiler maintenance
7043 3 Burn starts since maint Burner ignition number reset after boiler maintenance
7044 3 Maintenance interval Operation boiler time before boiler maintenance
7045 2 Time since maintenance Operation boiler time reset after boiler maintenance
7051 3 Message ionization current Ionization current value
7130 2 Chimney sweep functionChimney swwp function:OnOff
7131 2 Burner output
Burner output power during chimney sweep function:
Partial loadFull loadMax heating load
7140 2 Manual controlManual control function:OnOff
7143 2 Controller stop functionController stop function:OnOff
7145 2 Controller stop setpoint Power setpoint during controller stop function
7146 2 Deaeration functionDeaeration function:OnOff
7147 2 Type of venting
Deaeration function mode:NoneHeating circuit continuous
Heating circuit cycledHot water continuousHot water cycled
7170 2 Telephone customer service
7231 2 Refilll time current week value displayed
7232 2 Refill time to date value displayed
7233 2 Number of refills to date value displayed
7244 3 Press superv water refill
Used sensor for water pressure supervision for refill function:NoneWith input H1With input H2 module 1With input H2 module 2With input H2 module 3With input H3
7250 3 PStick storage pos Selection of the dataset number to write/read
7251 3 Parameter Description of dataset selected
7252 3 PStick command
Actions with Pstick:No operationReading from stickWriting on stick
7253 3 PStick progressThe progress made appears as a percentage which, when stick operation is actpercentage already completed.
7254 3 Parameter
Status of Pstick:No stickNo operationWriting on stick
-
8/10/2019 SERVICE Luna Platinum Ed 8
22/42
Reading from stickEMC test activeWriting errorReading errorIncompatible data setWrong stick typeStick format errorCheck data setData set disabledReading disabled
Parameter Level INPUT/OUTPUT TEST
7700 3 Relay test
Operatin relays test:No testEverything offRelay output QX1Relay output QX2Relay output QX3Relay output QX4Relay output QX21 module 1Relay output QX21 module 2Relay output QX21 module 3Relay output QX22 module 1Relay output QX22 module 2Relay output QX22 module 3Relay output QX23 module 1
Relay output QX23 module 2Relay output QX23 module 3
7730 3 Outside temp B9 value displayed
7750 3 Hot waterr temp B3 value displayed
7760 3 Boiler temp B2 value displayed
7820 3 Sensor temp BX1 value displayed
7821 3 Sensor temp BX2 value displayed
7822 3 Sensor temp BX3 value displayed
7830 3 Sensor temp BX21 module 1 value displayed
7831 3 Sensor temp BX22 module 1 value displayed
7832 3 Sensor temp BX21 module 2 value displayed
7833 3 Sensor temp BX22 module 2 value displayed
7834 3 Sensor temp BX21 module 3 value displayed
7835 3 Sensor temp BX22 module 3 value displayed
7840 3 Voltage signal H1 value displayed
7841 3 Contact state H1 value displayed7845 3 Voltage signal H2 value displayed
7846 3 Contact state H2 value displayed
7848 3 Voltage signal H2 module 2 value displayed
7849 3 Contact state H2 module 2 value displayed
7851 3 Voltage signal H2 module 3 value displayed
7852 3 Contact state H2 module 3 value displayed
7862 3 Frequency H4 value displayed
7860 3 Contact state H4 value displayed
7865 3 Contact state H5 value displayed
-
8/10/2019 SERVICE Luna Platinum Ed 8
23/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
24/42
8131 3 state displayed
8138 3 Cascade flow temp value displayed
8139 3 Cascade flow temp setp value displayed
8140 3 Cascade return temp value displayed
8141 3 Cascade return temp setp value displayed
8150 3 Source seq ch'over current value displayed
Parameter Level DIAGNOSTICS HEAT GENERATION
8304 3 Boiler pump Q1 value displayed
8308 3 Boiler pump speed value displayed
8310 2 Boiler temperature value displayed
8311 2 Boiler setpoint value displayed
8312 3 Boiler switching point value displayed
8313 3 Parameter value displayed
8314 2 Boiler return temp value displayed
8315 2 Boiler return temp setpoint value displayed
8316 2 Flue gas temp value displayed
8318 3 Flue gas temp max value reset
8321 2 Primary exchanger temp value displayed
8323 2 Fan speed value displayed
8324 3 Set point fan value displayed
8325 3 Current fan control value displayed
8326 2 Burner modulation value displayed
8327 3 Water pressure value displayed
8329 3 Ionization current value displayed
8330 3 Hours run 1st stage value reset8331 3 Start counter 1st stage value reset
8338 3 Hours run heating mode value reset
8339 3 Hours run HW value reset
8390 3 Current phase number value displayed
8499 3 Collector pump 1 value displayed
8501 3 Solar ctrl elem buffer value displayed
8502 3 Solar ctrl elem swi pool value displayed
8510 3 Collector temp 1 value displayed
8511 3 Collector temp 1 max value reset
8512 3 Collector temp 1 min value reset
8513 3 dt collector 1/exchanger 1 value displayed
8513 3 dt collector 1/HW value displayed
8514 3 dt collector 1/buffer value displayed
8515 3 dt collector 1/swimming pool value displayed
8519 3 Solar flow temp value displayed8520 3 Solar return temp value displayed
8527 1 Total Solar Gain value reset
8530 1 Hours run solar value reset
8531 1 Hours run collect overtemp value reset
8532 1 Hours run collector pump value reset
8560 3 Solid fuel boiler temp value displayed
8570 3 Hours run solid fuel boiler value reset
Parameter Level DIAGNOSTICS CONSUMERS
-
8/10/2019 SERVICE Luna Platinum Ed 8
25/42
8700 3 Outside temp value displayed
8701 3 Outside temp min. value reset
8702 3 Outside temp max. value reset
8703 3 Outside temp attenuated value reset
8704 3 Outside temp composite value displayed
8730 3 Central heating pump 1 value displayed
8731 3 Heat circ mix valve 1 open value displayed
8732 3 Heat circ mix valve 1 close value displayed
8740 3 Room temp 1 value displayed
8741 3 Room setpoint 1 value displayed8743 3 Flow temp 1 value displayed
8744 3 Flow temp setpoint 1 value displayed
8749 3 Room thermostat 1 value displayed
8760 3 Central heating pump 2 value displayed
8761 3 Heat circ mix valve 2 open value displayed
8762 3 Heat circ mix valve 2 close value displayed
8770 3 Room temp 2 value displayed
8771 3 Room setpoint 2 value displayed
8773 3 Flow temp 2 value displayed
8774 3 Flow temp setpoint 2 value displayed
8779 3 Room thermostat 2 value displayed
8790 3 Central heating pump 3 value displayed
8791 3 Heat circ mix valve 3 open value displayed
8792 3 Heat circ mix valve 3 close value displayed
8800 3 Room temp 3 value displayed8801 3 Room setpoint 3 value displayed
8804 3 Flow temp 3 value displayed
8803 3 Flow temp setpoint 3 value displayed
8809 3 Room thermostat 3 value displayed
8820 3 Hot water pump value displayed
8830 3 Hot water temp 1 value displayed
8831 3 Hot water temp setpoint value displayed
8832 3 Hot water temp 2 value displayed
8835 3 Hot water circulation temp value displayed
8836 3 HW charging temp value displayed
8852 3 Instant HW heater temp value displayed
8853 3 Instant HW heater setpoint value displayed
8860 3 Hot water flow value displayed
8875 3 Flow temp setp VK1 value displayed
8885 3 Flow temp setp VK2 value displayed8895 3 Flow temp setp VK3 value displayed
8900 3 Swimming pool temp value displayed
8901 3 Swimming pool setpoint value displayed
8930 3 Primary controller temp value displayed
8931 3 Primary controller setpoint value displayed
8950 3 Common flow temp value displayed
8951 3 Common flow temp setpoint value displayed
8952 3 Common return temp value displayed
8962 3 Common output setpoint value displayed
-
8/10/2019 SERVICE Luna Platinum Ed 8
26/42
8980 3 Buffer temp 1 value displayed
8981 3 Buffer setpoint value reset
8982 3 Buffer temp 2 value displayed
8983 3 Buffer temp 3 value displayed
9005 3 Water pressure H1 value displayed
9006 3 Water pressure H2 value displayed
9009 3 Water pressure H3 value displayed
9031 3 Relay output QX1 value displayed
9032 3 Relay output QX2 value displayed
9033 3 Relay output QX3 value displayed
9050 3 Relay output QX21 module 1 value displayed9051 3 Relay output QX22 module 1 value displayed
9052 3 Relay output QX23 module 1 value displayed
9053 3 Relay output QX21 module 2 value displayed
9054 3 Relay output QX22 module 2 value displayed
9055 3 Relay output QX23 module 2 value displayed
9056 3 Relay output QX21 module 3 value displayed
9057 3 Relay output QX22 module 3 value displayed
9058 3 Relay output QX23 module 3 value displayed
Parameter Level BURNER CONTROL
9500 3 Prepurge time Fan running time of prepurge
9504 3 Required speed prepurging Prepurging fan speed
9512 2 Required speed ignition Ignition fan speed
9524 2 Required speed LF Minimum power fan speed
9529 2 Required speed HF Maximum power fan speed9540 3 Postpurge time Fan running time of postpurge
9650 3 Chimney drying
Mode:OffTemporarilyPermanently
9651 3 Req speed chimney drying Fan speed during the function
9652 3 Duration chimney drying Operation time of function
-
8/10/2019 SERVICE Luna Platinum Ed 8
27/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
28/42
3 ERROR LIST
ErrorInternal
CodeDescription
10 Outside sensorCentral heating enabled without any control (roomthermostat, room unit o outside sensor) or outside sensorfault
20 Boiler sensor 11 Short circuit
2 Open circuit
25 Boiler sensor solid fuel Solid fuel boiler sensor not found or in short circuit
26 Common flow sensor Common flow sensor not found or in short circuit
28 Flue gas temp sensor
539 Short circuit (lockout)
540 Open circuit (lockout)
543 Short circuit (temporary error)
544 Open circuit (temporary error)
30 Flow sensor 1 Flow sensor mixing zone 1 not found or in short circuit
31 Flow sensor cooling 1 Flow sensor cooling circuit not found or in short circuit
32 Flow sensor 2 Flow sensor mixing zone 2 not found or in short circuit
38 Flow sensor prim contr Flow sensor primary controller not found or in short circuit
40 Return sensor 11 Short circuit
2 Open circuit
46 Return sensor cascade Return sensor cascade not found or in short circuit
47 Common return sensor Common return sensor not found or in short circuit
50HW sensor 1 (boiler withtank)
1 Short circuit
2 Open circuit
52 HW sensor 2 Solar DHW sensor not found or in short circuit
54 HW flow sensor DHW flow sensor not found or in short circuit
57 HW circulation sensor DHW circulation sensor not found or in short circuit
60 Room sensor 1 Room sensor circuit 1 not found or in short circuit
65 Room sensor 2 Room sensor circuit 2 not found or in short circuit
68 Room sensor 3 Room sensor circuit 3 not found or in short circuit
70 Storage tank sensor 1 Storage tank sensor 1 not found or in short circuit
71 Storage tank sensor 2 Storage tank sensor 2 not found or in short circuit
72 Storage tank sensor 3 Storage tank sensor 3 not found or in short circuit
73 Collector sensor 1 Solar collector sensor 1 not found or in short circuit
74 Collector sensor 2 Solar collector sensor 2 not found or in short circuit
78 Water pressure sensor
506 Short circuit (lockout)
560 Short circuit (temporary error)
793 Automatic filling loop error (lockout)797 Automatic filling loop error (temporary error)
81 LPB short-circuit/comm LPB bus error
82 LPB address collision More than 1 boiler using in the same address
83 BSB short-circuit No comunication / comunication error
84 BSB address collision More than 1 room unit using in the same Central heating
85 BSB Radio communication No radio comunication
91 Data loss in EEPROM 499 Internal counter out of range
98 Extension module 1 External modul 1 not found
99 Extension module 2 External modul 2 not found
100 2 clock time masters Not correct configuration of clock time
105 Maintenance message
109 Boiler temp supervision503 Flatness 2 test on flow sensor
504 Flatness 2 test on return sensor
-
8/10/2019 SERVICE Luna Platinum Ed 8
29/42
110 Lockout SLT
419 Maximum temperature of Electronic Safe Limit temperature
420Return temperature higher than flow temperature more than10K (temporary error)
421Return temperature egual or higher than flow temperaturemore than 10K-2
426 Temperature slope
427 Unlock limit of temperature slope not reached
428 Flow return temperature higher than 56K (temporary error)
429 Unlock limit of Flow return temperature higher than 56K
431Accepted times return temperature higher than flowtemperature more than 10K reached (lockout error)
436 Electronic Safe Limit temperature on return temperature
437 Accepted times Temperature slope reached
438Accepted times Flow return temperature higher than 56Kreached (lockout error)
111 Shutdown limit thermost Maximum limit of flow temperature
117 Water pressure too high
565 Static water pressure limit (lockout error) > 2.8 bar
566 Static water pressure limit (temporary error) > 2.8 bar
118 Water pressure too low Static pressure limit (lockout error) < 0.5 bar
119 Shutd water press swi563 Water pressure limit (lockout error)
564 Water pressure limit (temporary error)
121 Flow temp CH1 Flow temperature Central heating 1 not reached
122 Flow temp CH2 Flow temperature Central heating 2 not reached
125 Boiler temp too high
500Reached limit of flow temperature of flow setpoint plus 30Kfor 2 times in 10 minutes
501 No flow temperature variation for 20 seconds
502 No return temperature variation for 20 seconds
126 HW charg temp Maximum temperature of DHW charging not reached
127 Legionella temp Legionella limit temperature not reached
128 Loss of flame in op Loss of flame during operation
130 Flue gas temp too high Flue temperature limit reached
132 Safety shutdown Lock on GP contact
133 Safety time exceeded Loss of flame during ignition phase
151 BMU internal
325 Software error
326 Software error
327Software error
328 Software error
329 Software error
330 Ingniter relay closing error
331 Ingniter relay opening error
332 Gas valve relay closing error
333 Gas valve relay opening error
334 Ingnition error of canal 2
335 Swithing off error of canal 2
336 Safety relay closing error
337 Safety relay opening error
338 Ingnition error of canal 1
339 Swithing off error of canal 1
152 Parameterization345 Software error on micro 1
346 Gas type change error
-
8/10/2019 SERVICE Luna Platinum Ed 8
30/42
347 Max fan speed = Postpurge fan speed accepted
572 Input HX parameterization: limit thermostat
573 Input HX parameterization574 Input HX parameterization: air presure switch
575 10V signal input parameterization
576 Input H6 with 2 different funtions associated
577 Input H7 with 2 different funtions associated
578 Input B4 with 2 different funtions associated
579 Bypass pump Q12 parameterization
580 Cooling request K28 parameterization
581 Water filling K34 parameterization
153 Unit locked Hardware reset button pressed more than 10 seconds
160 Fan speed threshold Fan speed threshold not reached
164 Flow press switch CH561 Flow pressure switch Central heating (lockout error)
562 Flow pressure switch Central heating (temporary error)
171 Alarm contact 1 active800 Alarm contact input H1
805 Alarm contact input H4
172 Alarm contact 2 active
801 Alarm contact input H2 of extension module 1
802 Alarm contact input H2 of extension module 2
803 Alarm contact input H2 of extension module 3
806 Alarm contact input H5
173 Alarm contact 3 active 807 Alarm contact input H6
174 Alarm contact 4 active804 Alarm contact input H3
808 Alarm contact input H7
176 Water press 2 too high 565 Static water pressure limit (lockout error)
177 Water press 2 too low 565 Static water pressure limit (lockout error)
178 Limit thermostat CH1 Limit thermostat Central heating 1 (mix zone)
179 Limit thermostat CH2 Limit thermostat Central heating 2 (mix zone)
195 Water refill time791 Water refill time for sigle refilling elapsed (lockout error)
795 Water refill time elapsed (temporary error)
196 Water refill time/week792 Water refill time weekly elapsed (lockout error)
796 Water refill time weekly elapsed (temporary error)
241 Flow sensor yield Flow sensor yield not found or in short circuit
242 Return sensor yield Return sensor yield not found or in short circuit243 Swimming pool sensor Swimming sensor not found or in short circuit
260 Flow sensor 3 Flow sensor mixing zone 1 not found or in short circuit
270 Exc temp diff h' exch 507Temperature differential between flow temperature andexchanger temperature - Dry fire (lockout error)
320 HW charging sensor Charging DHW sensor not found or in short circuit
321 HW outlet sensor1 Short circuit
2 Open circuit
322 Water press 3 too high 565 Static water pressure limit (lockout error)
323 Water press 3 too low 565 Static water pressure limit (lockout error)
324 BX same sensors More than one sensor with the same function associated
325 BX/e'module same sensMore than one sensor (also on external module) with thesame function associated
326 BX/m'grp same sensMore than one sensor (also on mixing zone) with the samefunction associated
327 E'module same funct More than one sensor on external module with the same
-
8/10/2019 SERVICE Luna Platinum Ed 8
31/42
function associated
328 Mix group same functMore than one sensor on mixing zone with the samefunction associated
329 E'mod/m'grp same functMore than one sensor (external module and mixing zone)with the same function associated
330 BX1 no function No function associated to input BX1
331 BX2 no function No function associated to input BX2
332 BX3 no function No function associated to input BX3
333 BX4 no function No function associated to input BX4
334 BX5 no function No function associated to input BX5
335 BX21 no function No function associated to input BX21
336 BX22 no function No function associated to input BX22
337 B1 no function No function associated to input B1
338 B12 no function No function associated to input B12
339 Coll pump Q5 missing Collector pump Q5 not found or not configurated
340 Coll pump Q16 missing Collector pump Q16 not found or not configurated
343 Solar integration missing Solar integrated not found or not configurated
344 Solar buffer K8 missing Solar buffer not found or not configurated
345 Sol swi pool K18 missing Swimming pool from solar not found or not configurated
346 Boiler pump Q10 missing Collector pump Q16 not found or not configurated
347 Solid fuel boil comp sensSolid fuel boiler comparative sensor not found or notconfigurated
348 Solid fuel boil addr err Solid fuel boiler address error
349 Buff valve Y15 missing Buffer valve not found or not configurated
350 Buffer address error Buffer address error
351 Prim/sys pump addr err System pump address error
353 Casc sens B10 missing Cascade sensor not found or not configurated
371 Flow temp CH3 Flow temperature Central heating 3 not reached
372 Limit thermostat CH3 Limit thermostat Central heating 3 (mix zone)
373 Extension module 3 External modul 3 not found
374 Sitherm Pro calculation
359 Control value out of range
360 Calculated value over the threshold
361 Calculated value under the threshold
362 Gas valve stepper position over the threshold
363 Gas valve stepper position under the threshold
364 Ionization current out of range
365 R value out of range
375 BV stepper motor
366 Open contact on stepper motor
367 Short circuit on stepper motor
368 Low supply voltage on stepper motor
369 High supply voltage on stepper motor
370 Prevention of startup for a stepper motor is interrupted
376 Drift test limit value
221 Fan speed out of range
357 Fan speed out of range
358Ionization or fan speed with electrode drift test not in thedefined area. Problem: Power supply, blower-PWM setting
371 Too much corrrection of drift test
372 Too much corrrection of drift test
373 Drift test performed 4 times consecutive (temporary error)
768 Control value limit reached during the test drift
769 Ionization drift crash during testing
-
8/10/2019 SERVICE Luna Platinum Ed 8
32/42
377 Drift test prevented 418 Drift test counter monitor has excedded
384 Extraneous ligth Flame present with gas valve closed
385 Mains undervoltage Low supply voltage
386 Fan speed tolerance Fan speed out of range
429 Dyn water pres too high558 Dynamic water pressure too high (lockout error)
559 Dynamic test times excedded (lockout error)430 Dyn water pres too low 557 Dynamic pressure test failed (lockout error)
431Primary exch sensor(aluminium exchanger)
1 Short circuit (temporary error)
2 Open circuit (temporary error)
547 Short circuit (lockout error)
548 Open circuit (lockout error)
432 Function ground missing746 Feedback error from PCB (SR)
747 Feedback erro from gas valve realy (BV1)
433 Heat exch temp508 Exchanger temperature > 95C (lockout error)
509 Exchanger temperature > 95C (temporary error)
-
8/10/2019 SERVICE Luna Platinum Ed 8
33/42
4 GAS ADAPTIVE SYSTEM
LUNA4 is provided with a brand new system GAC (Gas Adaptive Control): the electroniccontrol together with the gas valve grant an automatic control of the combustion and ensurethe following advantages during the installation as well as for the end user:
Reduction of the time for the installation, as any manual intervention has been deleted(adjustment or nozzles change); The boiler is able to adapt to the quality of the gas and to the length of the flue tubesmaintaining a constant efficiency helping a reduction of the gas consumption and generatingless pollution.
The Gas Adaptive System maintains correct combustion by comparing the measured FlameSignal and the Reference Flame Signal. The Reference Signal follows a set curve dependingon fan speed and it is part of the software.
The system measures constantly the signal during the operation of the boiler and adjusts thegas flow rate in order to maintain the correct signal and the correct CO level. In this way isalso considered the oxidation of the component (flame electrode and burner).
The electronic gas valve has a modulator used to set the properly flame signal and so thecorrect air / gas ratio (LAMBDA).If the system is not able to assure the correct flame signal the boiler goes in lockout.
The flame signal detected by the burner control is independent from:- value and type of supply voltage;- quality of the ground in the installation.
-
8/10/2019 SERVICE Luna Platinum Ed 8
34/42
5 FAULT FINDING1 Initial Fault Finding Checks
1. Check that gas, water and electrical supplies are availableat the boiler.
2. Electrical supply = 230V ~ 50 Hz.
4. The preferred minimum gas pressure is 10 mbar.
5. Carry out electrical system checks, i.e. Earth Continuity,Resistance to Earth, Short Circuit and Polarity with a suitablemeter.
6. Ensure all external controls are calling for heat and checkall external and internal fuses. Before any servicing orreplacement of parts, ensure the gas and electrical suppliesare isolated.
18.2 Error Codes1. If a fault occurs on the boiler an error code may be shownby the facia display.
2. The codes are either a flashing two or three digit, numberpreceded by the symbol 'E'.
E20, E28, E40, E50, E83, E151, E160 and E384 indicate possiblefaulty components.
E110 and E111 shows overheat of the primary.
E117 is displayed when the primary water pressure is morethan 2.7 bar.
E118 is displayed when the primary water pressure is lessthan 0.5 bar.
E133 indicates that the gas supply has been interrupted,ignition has failed or the flame has not been detected.
E125 is displayed in either of two situations:-i) If within 15 seconds of the burner lighting the boilertemperature has not changed by 1.ii) If within 10 minutes of the burner lighting the boilertemperature twice exceeds the selected temperature by 30.In these instances poor primary circulation is indicated.
E128 is displayed if there has been a flame failure during normalburner operation.
3. By pressing the 'Reset' button for between 1-3 seconds whenE 110, E125 & E133 are displayed it is possible to relight theboiler.
4. If this does not have any effect, or error codes are displayedregularly further investigation is required.
.
NOTE: These checks must be repeated after anyservicing or fault finding.
NOTE: When instructed press and hold
the Reset for between 1-3 seconds toreset the boiler.
E20 Central Heating Flow NTC Fault
E28 Flue NTC Fault
E40 Central Heating Return NTC Fault
E50 Hot Water NTC Fault
E83 Communications error
E109 Pre-Circulation Fault
E110 Safety Thermostat Operated
E111 Maximum flow temperature exceeded
E117 System Water Pressure Too High
E118 System Water Pressure Too Low
E125 Circulation Fault (Primary Circuit)
E128 Flame Failure
E130 Flue NTC Operated
E133 Interruption Of Gas Supply or Flame Failure
E151 PCB Fault
E160 Fan or Fan Wiring Fault
E384 False flame
Table Of Error Codes
.
-
8/10/2019 SERVICE Luna Platinum Ed 8
35/42
Refer to Annex 1 Illustrated Wiring Diagram for position of terminals and componentsCentral Heating - Follow operational sequence
NO
Turn on mains power.The display illuminates
Go to section A
*Error 110 flashingError 111 flashingError 133 flashingError 125 flashing
Press the Reset button forbetween 1-3 seconds
If the E110 or E111 is stillflashing. Go to section H
Error 20, 28, 40 or 50 flashing Go to section D
Error E109 flashing Go to section J
Set the Central Heatingtemperature toMaximum. Pump runs.
Ensure all controls andProgrammers are callingfor heat
Ensure controls are set todemand and verify the
contacts are closed
Go to section B
Error E125 flashingafter 1 minute
Fan runs after up to 3 minutes Error 160 flashingGo to section C
Fan runs at correct speed Error 160 flashingGo to section C
Spark at ignition electrodes forup to 5 seconds and for 4attempts.
Error 133 flashingGo to section FPress the Reset button forbetween 1-3 seconds
Check the Central HeatingNTC sensorGo to section D
Burner output modulates tomaintain the temperature set
Burner goes out Fan stops after 10 secondsOperation sequencesuccessful
YES
YES
YES
YES
YES
YES
YES YES
YES
YES
YES
YES
YES NO
NO
NO
NO
NO
NO
NO
NO
NO
Go to section E
Burner lights Burner does not stay alightafter 5 seconds
YES
YES
NO
YES
NO3 way valve open to centralheating circuit
Go to section K
NO
YES
Error 117 or 118 flashing Go to section I
YES
NO
Error E110 or E111flashing
NO
Go to section H
YES
CH Rad. Symbol flashes
NO
Error E130 flashing Go to section MYES
*If Error 83, 151 or 384 is flashing or re-occurs regularlycheck all PCB and communication connections, if this hasno effect chan e PCB.
Error 133 flashing. Go to section GYES
Error 128 or Error 374 flashing. Go to section N
NO
-
8/10/2019 SERVICE Luna Platinum Ed 8
36/42
-
8/10/2019 SERVICE Luna Platinum Ed 8
37/42
Fault Finding Solutions Sections
Main terminals L and N Check electrical supply
YESMain terminal fuse Replace fuse
NO
PCB X10 connectorMains terminals L & N
Check wiring
NO
A
Connection OK atconnector x40
Is there 230V at:
NO
1.
2.
3.
BSwitch to DHW mode maximum flow rate and pressreset. During the next three minutes is there:-
230V atPump
NO
230V at PCB connector x13 pump terminalsBlue to Brown (See Wiring Diagram)
Replace PCB
NO
230V between PCB connector x13 pumpterminal Blue and PCB connector x11 pumpterminal Black.(See Wiring Diagram)
YES
Displayilluminated
C
Is there 230V AC at fan terminals connectorX11 blue to brown. See Wiring Diagram
1.
Fan jammed of faulty winding
YES
Replace PCB
NO
Replace fan
YES
Fan connections correct at fan and PCBConnectors X11 & X23 See Wiring Diagram
YES
Make connections
NO
Main or DisplayPCB fault
NO
YES
Replace PCB
YES
ReplacePump
YES
NO
Check wiring
-
8/10/2019 SERVICE Luna Platinum Ed 8
38/42
D
Cold resistance approximately10k@ 25 C (DHW and CH sensors)(resistance reduces with increase in temp.)
Replace sensorNO
G
Gas at burner Ensure gas is on and purgedNO
Check wiring & PCB X15 connector, is there 24 VDC across Gas valve terminals black to green.See Wiring Diagram.
Replace PCB
NO
Replace gas valveYES
F Check and correct if necessary1. Ignition electrode and lead2. Electrode connection3. Spark gap and position
Check wiring.Voltage at PCB X15 connector is24V DC across the igniter unitterminals Blue to Brown for 5
seconds during ignition phase . SeeWiring Diagram
YES
Replace PCBNO
Replace igniter unitYES
Check and correct if necessary
1.CO2 values - see instruction2. Flame sensing electrode and lead connections3. Flame sensing electrode position
2.
Replace PCB
NO
Replace flame sensing electrode
YES
E
Check the gas supply pressure:For Natural Gas greater than10 - 11 mbar
1.
Flame current should be more than 1,7 A
Temperature sensor faulty.Check correct location and wiring
YES
-
8/10/2019 SERVICE Luna Platinum Ed 8
39/42
YES
YESI CH system pressure less than 0.5 baror more than 2.7 bar.
Restore System Pressure
J Ensure that the system andboiler are fully vented. System fault, correct.
NO
Check flow temperature sensor connectionsand position.Cold resistance approximately.10k@ 25 C (CH sensors)(resistance reduces with increase in temp.)
YES
Replace sensorNO
Check wiring and pcb connection atconnector x22 is there approx. 5 VDC between the green and black
terminals
NOReplace pressure sensor
YES
YES
Go to section B
K Is there 230V at:
Motor, 3 way valve
1
2
PCB connector x13 3 way valve terminalsBlue to Black central heating modeBlue to Brown domestic hot water mode
See Wiring Diagram
YES
Replace motor 3 way valve
NO
Replace PCB
Check 3 way valve cable.
Replace PCBNO
Overheat thermostat operated orfaulty.
YES
ReplacePCB
Check for and correct anysystem faults.
NO
Replace safety thermostatYES
Is E110 or E111 stillflashing
Check Flow, Return,sensors. See section D
Allow to cool. Continuityacross thermostat terminals
more than 1.5 ohm
YESNO
NO
H
-
8/10/2019 SERVICE Luna Platinum Ed 8
40/42
L Is mains water filter andassembly clean and the rotor freeto move.
NO
Clean or replace
YES
PCB connector x22Hall effect sensor terminals.Check that the voltage is approximately5 V DC between Red and BlueSee Wiring Diagram
Replace Hall Effect SensorYES
NO
Replace PCB
Temperature sensors faulty.Cold resistance approximately10k@ 25 C (CH sensor)20k@ 25 C (Flue sensor)(resistance reduces with increase in temp.)
1.
Replace sensorNO
If pump is running the heat exchanger could beobstructed
2. Replace heat exchangerYES
M
N
E128 flashingE374 flashing
NO
E376 flashing
YES NO 1.
2.
Replace PCB
NO
Replace flamesensingelectrode
YES
Replace gasvalve
YES
Replace PCBNO
1.Reset Drift Test results:
-press both buttons for 6 seconds-enter at specialist level-go to Sitherm Pro menu-go to parameter 2749-select yes
Check if there isrecirculation of flue gas inthe sealed chamber
Check supply pressure atthe gas valveCheck and correct ifnecessary:1. Selection of gas type2. Flame sensingelectrode and leadconnections3. Flame sensingelectrode position
Check wiring and PCB -X25 connector (stepper
motor gas valve) and X15(EV gas valve)
Check and correct ifnecessary:1. Selection of gas type2. Flame sensingelectrode position
YES
-
8/10/2019 SERVICE Luna Platinum Ed 8
41/42
WIRING DIAGRAM
-
8/10/2019 SERVICE Luna Platinum Ed 8
42/42
6 BURNER PHASE (fault history)
Phase Description
1 Permitted afterburn time2 Permitted time with air pressure switch closed or fan speed
3 Permitted time with fan speed
4 Standby
5 Start prevention
6 Maximum fan ramp-up time to prepurge speed
7 Maximum fan ramp-up time to ignition speed
8 Preventilation
9 Maximum time to reach ignition speed after prepurging
10 Maximum waiting time 1
11 Maximum waiting time 212 Preignition time
13 1st safety time (gas valve open)
14 2nd safety time (gas valve close)
15 Interval (flame stabilization)
16 Control mode
17 Change to postpurging at last operating speed
18 Change to postpurging at prepurge speed
19 Postpurging at last operating speed
20 Temporary error
21 Lock-out error
22 Postpurging at prepurge speed23 Chimney drying