service manaual m cell6 (68p02901w85 b uk)

Upload: ctdisupplyeurope

Post on 03-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    1/1102

    /

    Manual Revision

    GMR-0131st May 0168P02901W85-B

    GSM-105-020

    Motorola manualaffected

    Incorporate this GMR only in the manual number and version listed below:

    68P02901W85-B Service Manual: M-Cell6

    Problem reports

    This revision provides a fix to the following problem reports:

    SR32665 M-Cell6diagnostics.

    SR37150 Polarized battery connectors

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    2/1102

    SR37150 Polarized battery connectors

    GSM-105-020

    Reason forrevision

    This revision provides additional and updated information as follows:

    Tech. 11 Introduction.

    Tech. 23 to 26 Acoustic noise specifications and power consumption note.

    Tech. 25, 28 to 210 Storage and operating humidities.

    Tech. 995 VSWR monitor option.Tech. 1025 NIU boot up sequence.

    Inst. 26 Storage and operating humidities.

    Inst. 39 and 4-7 Reference to new packaging materials.

    Inst. 311 to 319 References to eyebolts removed.

    Inst 335 IBB connection diagram for two BTS cabinets.

    Inst. 386 Polarized battery connectors.

    Inst. 392 to 394 Care of fibre optic cables.

    Maint. 13 Storage and operating humidities.

    Action

    Remove and replace pages in the Manual as follows:

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    3/1102

    Cellular Infrastructure Group

    GSM-105-020

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    4/1102

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    5/1102

    GSM-105-020

    Service Manual

    M-Cell6

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    6/1102

    GSM-105-020

    Copyrights, notices and trademarks

    Copyrights

    The Motorola products described in this document may include copyrighted Motorola computer

    programs stored in semiconductor memories or other media. Laws in the United States and other

    countries preserve for Motorola certain exclusive rights for copyright computer programs, including the

    exclusive right to copy or reproduce in any form the copyright computer program. Accordingly, any

    copyright Motorola computer programs contained in the Motorola products described in this document

    may not be copied or reproduced in any manner without the express written permission of Motorola.

    Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by

    implication, estoppel or otherwise, any license under the copyrights, patents or patent applications of

    Motorola, except for the rights that arise by operation of law in the sale of a product.

    RestrictionsThe software described in this document is the property of Motorola. It is furnished under a license

    agreement and may be used and/or disclosed only in accordance with the terms of the agreement.Software and documentation are copyright materials. Making unauthorized copies is prohibited by

    law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored

    in a retrieval system, or translated into any language or computer language, in any form or by any

    means, without prior written permission of Motorola.

    AccuracyWhile reasonable efforts have been made to assure the accuracy of this document, Motorola

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    7/1102

    GSM-105-020

    Issue status of this manual 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General information 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    First aid in case of electric shock 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Reporting safety issues 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Warnings and cautions 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General warnings 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Human exposure to radio frequency energy (PCS1900 only) 9. . . . . . . . . . . . . . . . . . . . . .

    Beryllium health and safety precautions 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General cautions 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Devices sensitive to static 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Motorola GSM manual set 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GMR amendment 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GMR amendment record 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Category 323Technical Description (Tech.) i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 1M-Cell6 cabinets overview i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Introduction Tech. 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Purpose Tech. 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Typical applications Tech. 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Facilities and functions Tech. 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Interconnection Tech. 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor installations Tech. 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    BTS functional diagram Tech 1 2

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    8/1102

    GSM-105-020

    Chapter 2

    M-Cell6 specifications i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Introduction Tech. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Cabinet enhancements Tech. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor cabinet BTS specifications Tech. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Environment Tech. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Dimensions Tech. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Floor weights Tech. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power requirements Tech. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Power consumption Tech. 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Acoustic Noise Tech. 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Outdoor cabinet BTS specifications Tech. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Environment Tech. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Dimensions Tech. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Floor weight Tech. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Power requirements Tech. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power consumption Tech. 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ancillary cabinet specifications Tech. 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Environment Tech. 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Dimensions Tech. 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Floor weight Tech. 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Side cabinet specifications Tech. 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    En ironment Tech 2 9

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    9/1102

    GSM-105-020

    Chapter 3

    M-Cell6 BTS cabinets i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BTS cabinet detail Tech. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Equipment Tech. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor BTS cabinet internal view Tech. 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor BTS dc cabinet internal view Tech. 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor BTS ac cabinet internal view Tech. 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    BTS cabinet equipment Tech. 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RF front end equipment Tech. 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digital modules power modules and fans Tech. 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Top panel detail Tech. 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    EGSM900 RF modules Tech. 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DCS1800/ PCS1900 RF modules Tech. 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power and signalling connections Tech. 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EGSM900 top panel diagram Tech. 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    EGSM900 top panel with ac adaption diagram Tech. 39. . . . . . . . . . . . . . . . . . . . . . . . . . . .DCS1800/ PCS1900 top panel diagram Tech. 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DCS1800/ PCS1900 top panel with ac adaption diagram Tech. 310. . . . . . . . . . . . . . . . . . .

    Top panel connectors Tech. 311. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Fan cooling system Tech. 312. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 312. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 312. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    I d bi t i m t T h 3 12

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    10/1102

    GSM-105-020

    Indoor dc power supply modules Tech. 319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PSM shelf Tech. 319. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Negative power supply module (NPSM) Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NPSM module external view Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Normal operation Tech. 320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alarm Monitoring Tech. 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Shutdown condition Tech. 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Regulated supply Tech. 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Monitor circuits Tech. 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Circuit protection Tech. 321. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LED display Tech. 322. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Positive power supply module (PPSM) Tech. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PPSM module view diagram Tech. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Normal operation Tech. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Alarm Monitoring Tech. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sh td diti T h 3 24

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    11/1102

    GSM-105-020

    Power distribution unit Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor cabinet Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor cabinet Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor cabinet PDU front panel Tech. 337. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor cabinet circuit breakers and fuses Tech. 338. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor cabinet PDU front panel Tech. 339. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor cabinet circuit breakers and fuses Tech. 340. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RF equipment detail Tech. 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ESGM900 cabinets Tech. 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DCS1800/ PCS1900 cabinets Tech. 341. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ESGM900 RF equipment location Tech. 342. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DCS1800/ PCS1900 RF equipment location Tech. 343. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Micro base control unit Tech. 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 344. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mBCU cage module external view Tech. 345. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Full size modules Tech. 345. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Half size modules Tech. 345. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mBCU cage backplane Tech. 346. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Backplane connectors Tech. 347. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Alarm board 6 (AB6) Tech. 348. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    O i T h 3 48

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    12/1102

    GSM-105-020

    Interconnect bus board Tech. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    IBB board view diagram Tech. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Interconnection diagram Tech. 361. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Cabinet intercabling diagrams Tech. 362. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 362. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor cabinet BTS interconnections Tech. 362. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Outdoor cabinet BTS interconnections Tech. 377. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 4M-Cell6 ancillary cabinets i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ancillary cabinet detail Tech. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General description Tech. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Equipment Tech. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ancillary cabinet internal detail Tech. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ancillary cabinet internal view diagram Tech. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ancillary cabinet top panel Tech. 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Top panel diagram Tech. 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Top panel connectors Tech. 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Power distribution panel detail Tech. 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    13/1102

    GSM-105-020

    Control and alarm assembly Tech. 419. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Control and alarm functions Tech. 419. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 419. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 419. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control and alarm assembly location diagram Tech. 419. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control and alarm assembly board Tech. 420. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Controls and indicators on control and alarm assembly Tech. 420. . . . . . . . . . . . . . . . . . . . .Alarm inputs Tech. 422. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Alarm signals Tech. 422. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control and alarm assembly board functional blocks Tech. 423. . . . . . . . . . . . . . . . . . . . . . .

    Fan cooling system Tech. 424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fan functions Tech. 424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Interconnect bus board Tech. 425. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Interconnect bus board functions Tech. 425. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Interconnection diagram Tech. 426. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 5M-Cell6 side cabinet i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Side cabinet detail Tech. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Side cabinet functions Tech. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Side cabinet internal view Tech. 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Safety labels location Tech. 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Internal safety labels location Tech. 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Side cabinet bottom panel Tech. 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sid bi t l d t il T h 5 6

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    14/1102

    GSM-105-020

    Power distribution panel Tech. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirement Tech. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PDP location diagram Tech. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PDP circuit breaker diagram Tech. 613. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Battery box circuit breakers and fuses Tech. 614. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LVD bypass assembly Tech. 615. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 615. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 615. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Bypass assembly: Front panel Tech. 615. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Controls, indicators and monitor points Tech. 616. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 617. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Communications power supply module (CPSM) Tech. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirement Tech. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CPSM module view diagram Tech. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 619. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Monitor circuits Tech. 619. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Circuit protection Tech. 619. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CPSM functional diagram Tech. 619. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Control and alarm assembly Tech. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functions Tech. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    R i t T h 6 20

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    15/1102

    GSM-105-020

    Air conditioner detail Tech. 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner internal view diagram Tech. 78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner components Tech. 710. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner electrical circuit Tech. 711. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner cooling circuit Tech. 712. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Cooling circuit diagram Tech. 712. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    HMS airflow paths Tech. 713. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Heat exchanger airflow Tech. 713. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Heat exchanger airflow path Tech. 713. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner airflow Tech. 714. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner airflow path diagram Tech. 714. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    HMS power distribution Tech. 715. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Heat exchanger power distribution Tech. 715. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner power distribution Tech. 715. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Intercabling diagram Tech. 716. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    HMS connection panels Tech. 717. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 717. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 717. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Heat exchanger connection panel Tech. 717. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air conditioner connection panel Tech. 718. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connection table Tech. 718. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Control board detail Tech. 719. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    O i T h 7 19

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    16/1102

    GSM-105-020

    Chapter 8

    M-Cell6 RF modules i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RF equipment detail Tech. 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RF modules description Tech. 81. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Receiver operating frequencies Tech. 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Receiver RF hardware Tech. 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Receive antenna transceiver interface (RATI) Tech. 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Receiver functions Tech. 83. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmitter RF operating frequency and channels Tech. 83. . . . . . . . . . . . . . . . . . . . . . . . .Transmitter RF hardware Tech. 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmit antenna transceiver interface (TATI) Tech. 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmitter functions Tech. 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mixer frequencies Tech. 84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Antenna duplexing Tech. 85. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transceiver control unit (TCU) detail Tech. 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functions Tech. 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transceiver carrier frequency bands Tech. 86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU circuitry Tech. 87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU external view Tech. 87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Maintenance ports Tech. 87. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Front panel switches Tech. 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Alarm reporting Tech. 88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LED T h 8 8

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    17/1102

    GSM-105-020

    TCU digital processing and control (DPC) board Tech. 822. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 822. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TCU control functions Tech. 822. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DPC board functional diagram Tech. 822. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU connections Tech. 823. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Data specifications Tech. 823. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Downlink (Tx) digital processing Tech. 823. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Uplink (Rx) digital processing Tech. 824. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DPC firmware tasks Tech. 824. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Processing and control Tech. 825. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TCU transceiver station manager (TSM) board Tech. 826. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 826. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TSM board functional block diagram Tech. 826. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Downlink traffic Tech. 827. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Uplink traffic Tech. 827. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Baseband hopping Tech. 827. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RSS processing Tech. 827. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Front end processing (FEP) Tech. 828. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Channel coder processing Tech. 828. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Time division multiplexed (TDM) interface Tech. 829. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transceiver control unit model B (TCU-B) detail Tech. 830. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functions Tech. 830. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 830. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 830. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transceiver carrier frequency bands Tech. 830. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU B i it T h 8 31

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    18/1102

    GSM-105-020

    TCU-B digital control and signal processing (DPC) board Tech. 841. . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 841. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Control functions Tech. 841. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DPC board functional diagram Tech. 841. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    2.048 Mbit/s fibre optic TDM links Tech. 842. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RSS processor Tech. 842. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EQCP processor Tech. 843. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCCP processor Tech. 843. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transceiver interface function Tech. 844. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Downlink (Tx) traffic Tech. 844. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Uplink (Rx) traffic Tech. 844. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Frequency hopping Tech. 845. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 845. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Synthesizer frequency hopping Tech. 845. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SFH diagram Tech. 845. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SFH description Tech. 845. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SFH through BCCH carrier diagram Tech. 846. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SFH through BCCH carrier description Tech. 846. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Baseband frequency hopping (BBH) Tech. 847. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BBH diagram Tech. 847. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Downlink direction Tech. 847. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Uplink direction Tech. 847. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmit signal routeing Tech. 848. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmit signal routeing functional diagram Tech. 849. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Receive signal routeing Tech. 850. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Receive signal routeing functional diagram Tech. 850. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    EGSM900 d l T h 8 51

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    19/1102

    GSM-105-020

    Combining bandpass filter (CBF) module Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Location Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements: Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Module view Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 861. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CBF functional diagram Tech. 862. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU-CBF functional diagram Tech. 862. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Air combining Tech. 863. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RF functional block diagram Tech. 863. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cavity combining block (CCB) module Tech. 864. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 864. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 864. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 864. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB module view diagram Tech. 864. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB functional description Tech. 865. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Cavity block control Tech. 865. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmit bandpass filter Tech. 865. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transmit antenna transceiver interface (TATI) Tech. 865. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TATI control board Tech. 865. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB functional diagram Tech. 866. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB configuration diagram Tech. 867. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB digital control Tech. 867. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CCB interconnection Tech. 868. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TATI control board redundancy Tech. 868. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Eight cell Omni configuration diagram Tech. 869. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    20/1102

    GSM-105-020

    Non-hybrid combiner (non-HCOMB) Tech. 878. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 878. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 878. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 878. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Limitations Tech. 878. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Non-HCOMB with power load module view diagram Tech. 879. . . . . . . . . . . . . . . . . . . . . . .

    Twin band pass filter (TBPF) Tech. 880. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 880. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 880. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 880. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Limitations Tech. 880. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RF blanking plates Tech. 881. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 881. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 881. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 881. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CBF type blanking plate view diagram Tech. 881. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DLNB blanking plate view diagram Tech. 882. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DCS1800/PCS1900 modules Tech. 883. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 883. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Module details Tech. 883. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low noise amplifier Tech. 884. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 884. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 884. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 884. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LNA module view diagram Tech. 884. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    F i l d i i T h 8 85

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    21/1102

    GSM-105-020

    VSWR Monitor Tech. 895. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 895. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Further details Tech. 895. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 9M-Cell6 digital modules i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital modules detail Tech. 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functions Tech. 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digital modules functional diagram Tech. 92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Main control unit (MCU) details Tech. 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Requirements Tech. 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Network connections Tech. 93. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MCU module view diagram Tech. 94. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MCU functions Tech. 95. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MCU functional diagram Tech. 96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MCU technical description Tech. 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Memory configurations Tech. 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Processor functionality Tech. 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    68LC060 processor Tech. 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    QUICC32 processor Tech. 97. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    ECC T h 9 8

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    22/1102

    GSM-105-020

    Sync block Tech. 915. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 915. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sync references Tech. 915. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sync test ports Tech. 916. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Functional description Tech. 916. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    OCXO Behaviour Tech. 916. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Code loading Tech. 917. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sync control Tech. 917. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sync memory Tech. 918. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Processor parallel interface Tech. 918. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Features controlled by the main processor Tech. 918. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GSM counters Tech. 918. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Events causing a main processor interrupt Tech. 919. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Man machine interface management Tech. 920. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 920. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MMI availability Tech. 920. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Remote login availability Tech. 920. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MMI functional block diagram Tech. 920. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Security management Tech. 921. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Function Tech. 921. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Level 1 Tech. 921. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Level 2 Tech. 921. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Level 3 Tech. 921. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    23/1102

    GSM-105-020

    Fibre optic extender (FOX) Tech. 929. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Tech. 929. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 929. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 929. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FOX module view diagram Tech. 929. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Functional description Tech. 930. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FOX module functional diagram Tech. 930. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Receiver Tech. 931. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Amplifier Tech. 931. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Transmitter Tech. 931. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Voltage regulators Tech. 931. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FOX module interconnection diagram Tech. 931. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Fibre optic multiplexer (FMUX) Tech. 932. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Tech. 932. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Requirements Tech. 932. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Location Tech. 932. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FMUX module view diagram Tech. 932. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Functional description Tech. 933. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FMUX functional diagram Tech. 933. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FMUX interconnection diagram Tech. 934. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Frame boundary Tech. 934. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Optical link maximum length Tech. 934. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .System restrictions Tech. 935. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .FMUX connections diagram Tech. 935. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MicroBCU redundancy Tech. 936. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mBCU architecture functional diagram Tech. 936. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MCU d d T h

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    24/1102

    GSM-105-020

    Test equipment Inst. 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Calibration requirements Inst. 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test lead connection diagram Inst. 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Equipment and materials Inst. 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maintenance equipment Inst. 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Materials required Inst. 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 2M-Cell6 site preparation i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Pre-installation requirements Inst. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pre-installation procedures Inst. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Torque values Inst. 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Site requirements Inst. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cabinet weights Inst. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cabinet dimensions Inst. 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Site dimensions Inst. 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor ac BTS site dimensions Inst. 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operating environment Inst. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Storage environment Inst. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power requirements Inst. 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Visiting the site Inst. 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Before departure to site Inst. 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    25/1102

    GSM-105-020

    Preparing for mounting an outdoor BTS Inst. 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installing the plinth Inst. 214. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cabinet plinth diagrams Inst. 215. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Preparing for mounting an indoor BTS Inst. 216. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 216. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Procedure Inst. 216. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Preparing for mounting an indoor ac BTS. Inst. 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Procedure Inst. 217. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Chapter 3M-Cell6 normal installation i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General installation information Inst. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.048 Mbit/s line testing Inst. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Torque values Inst. 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation steps Inst. 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    BTS cabinet configurations Inst. 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor BTS cabinet internal view diagram Inst. 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor BTS cabinet internal view diagram Inst. 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ancillary cabinet internal view diagram Inst. 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Side cabinet internal view diagram Inst. 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat exchanger unit internal view diagram Inst. 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Air conditioner unit internal view diagram Inst. 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Equipment delivery and packaging Inst. 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    26/1102

    GSM-105-020

    Earthing and transient protection Inst. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Transient and lightning protection Inst. 323. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing power and earth cabling Inst. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor cabinets Inst. 324. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Outdoor cabinets Inst. 325. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting dc power cables Inst. 326. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Negative earth cabinet Inst. 326. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Positive earth cabinet Inst. 326. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting single-phase ac power cables Inst. 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Preparing for connection Inst. 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting to the main isolator Inst. 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting to the power outlet Inst. 327. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting three-phase ac power cables Inst. 328. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Preparing for connection Inst. 328. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting to the main isolator Inst. 328. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Connecting to the power outlet Inst. 329. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Connecting antennas to indoor cabinets Inst. 330. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 330. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RF configurations Inst. 330. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GSM900 BTS top panel diagram Inst. 331. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GSM900 BTS top panel configuration diagrams Inst. 332. . . . . . . . . . . . . . . . . . . . . . . . . .

    DCS1800 and PCS1900 BTS top panel diagrams Inst. 333. . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    27/1102

    GSM-105-020

    Input/output device cabling Inst. 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Introduction Inst. 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PIX connector location diagram Inst. 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Relay-closure outputs Inst. 350. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Dry-contact inputs Inst. 351. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PIX with Krone interconnection diagram Inst. 351. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Krone box output details Inst. 352. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PIX without Krone interconnection diagram Inst. 353. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PIX connector pinout details Inst. 354. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing power supply modules Inst. 356. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 356. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DC power input modules location diagram Inst. 356. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AC power supply modules Inst. 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Pre-installation Inst. 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installation procedure Inst. 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing CPSM modules Inst. 357. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CPSM module view diagram Inst. 358. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installation procedure Inst. 358. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installing TCU modules Inst. 359. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 359. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Before installation Inst. 359. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Preparing the cabinet Inst. 359. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing and connecting TCU modules Inst. 360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU front panel diagram Inst. 362. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TCU-B front panel diagram Inst. 363. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    28/1102

    GSM-105-020

    Chapter 4

    M-Cell6 installation with additional equipment cabinet and battery box i.General installation information Inst. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation steps Inst. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.048 Mbit/s line testing Inst. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Torque values Inst. 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor BTS ac cabinet configurations Inst. 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor BTS ac cabinet Inst. 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Additional equipment cabinet Inst. 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Battery box front view Inst. 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery box rear view Inst. 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Equipment delivery and packaging Inst. 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Packaging Inst. 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Equipment Inst. 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Unpacking the cabinet Inst. 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tools Inst. 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Dismantling the shipping crate Inst. 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Unpacking procedure Inst. 410. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Returning the packing material Inst. 410. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mounting M-Cell6 indoor cabinets Inst. 411. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 411. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .M-Cell6 cabinets Inst. 411. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tools Inst. 411. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mounting bolts and washers Inst. 411. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    29/1102

    GSM-105-020

    Top panel interconnections Inst. 429. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Indoor BTS ac cabinet top panel Inst. 429. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Additional equipment cabinet top panel Inst. 430. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    One BTS and one battery box Inst. 431. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    One BTS and two battery boxes Inst. 431. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Two BTS units and one battery box Inst. 431. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Two BTS units and two battery boxes Inst. 432. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Three BTS units and two battery boxes Inst. 432. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Four BTS units and two battery boxes Inst. 433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Battery box interconnection details Inst. 434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery box output connection details Inst. 435. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Duplexer configurations Inst. 436. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    One BTS and one duplexer Inst. 437. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Two BTSs and two duplexers Inst. 437. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Three BTSs and three duplexers Inst. 437. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Communications power supply module Inst. 438. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 438. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CPSM module view diagram Inst. 438. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation procedure Inst. 439. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 5M-Cell6 installation with battery box Inst. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    General installation information Inst. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installation steps Inst. 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    30/1102

    GSM-105-020

    Battery box installation Inst. 514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor ac cabinet and battery box view diagram Inst. 514. . . . . . . . . . . . . . . . . . . . . . . . . . .Cabinet cable set-up Inst. 515. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor ac cabinet cable fixings diagram Inst. 516. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Securing the cabinets Inst. 517. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery installation procedure Inst. 518. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery connection procedure Inst. 519. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery box front view diagram Inst. 519. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Installing the ac power supply Inst. 520. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 520. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Before installation Inst. 520. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Preparing the cabinet for the ac cable Inst. 520. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AC power interface module diagram Inst. 521. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Circuit breaker internal view diagram Inst. 521. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AC power cable installation Inst. 522. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Circuit breaker ac connection diagram Inst. 522. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ACPM installation Inst. 523. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Communications power supply module (CPSM) Inst. 524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CPSM module view diagram Inst. 524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installation procedure Inst. 525. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 6M-Cell6 normal commissioning i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    M-Cell6 commissioning Inst. 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    31/1102

    GSM-105-020

    Power-up an indoor (dc) BTS Inst. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Overview Inst. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power-up procedure Inst. 612. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor BTS cabinet power supply location diagram Inst. 613. . . . . . . . . . . . . . . . . . . . . . . .Indoor cabinet BTS circuit breakers and fuses Inst. 614. . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor cabinet BTS PDU front panel diagram Inst. 615. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Commissioning the heat exchanger Inst. 616. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 616. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test equipment requirements Inst. 616. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Airflow paths Inst. 616. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Heat exchanger airflow path diagram Inst. 617. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test connector Inst. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test connector diagram Inst. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test facilities Inst. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test signals Inst. 618. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test procedure Inst. 619. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Commissioning the air conditioner Inst. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overview Inst. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Test equipment requirements Inst. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Airflow paths Inst. 620. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Air conditioner airflow path diagram Inst. 621. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test connector Inst. 622. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test connector diagram Inst. 622. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test facilities Inst. 622. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test signals Inst. 623. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Test procedure Inst. 623. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Initialization process Inst. 624. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 7/28/2019 Service Manaual M Cell6 (68p02901w85 b Uk)

    32/1102

    GSM-105-020

    Sample form 1: Request for connection Inst. 711. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sample form 2: Completion and inspection form Inst. 713. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Category 523Maintenance Information (Maint.) i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chapter 1M-Cell