17
Project #1306 the Crest (106 E 35 Ave) #1306 Date Thursday, June 14th, 2018 Address 106 East 35th Ave Created By Chris Godler Created Thursday, June 14th, 2018 Modified Wednesday, March 20th, 2019 Shop Drawing #023 Subject: Record Record Name: Shop drawing #023 - Elevator Design & Finish Form Code: 14-100 Drawing Description: Elevator Design & Finish Form Vendor (Trade): Schindler Required by: 2018-12-17 Submissions # Received From Trade Sent To Consultant Received From Consultant Review Status 1 2018-06-14 2018-06-14 2018-07-04 Approved 2 2018-12-10 2018-12-10 2019-01-07 Approved

Upload: others

Post on 16-Apr-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Project #1306 the Crest (106 E 35 Ave) #1306Date Thursday, June 14th, 2018

Address 106 East 35th Ave

Created By Chris GodlerCreated Thursday, June 14th, 2018

Modified Wednesday, March 20th, 2019

Shop Drawing #023

Subject:

Record

Record Name: Shop drawing #023 - Elevator Design & Finish Form

Code: 14-100Drawing Description: Elevator Design & Finish Form

Vendor (Trade): Schindler Required by: 2018-12-17

Submissions

# Received From Trade Sent To ConsultantReceived From Consultant

Review Status

1 2018-06-14 2018-06-14 2018-07-04 Approved

2 2018-12-10 2018-12-10 2019-01-07 Approved

 

Schindler Elevator Corporation Performance Construction Ltd. 1150-21331 Gordon Way Richmond, BC V6W 1J9

Contact: Rocky Gill Opportunity Number: 0200749445

Telephone 7783274068 Project: The Crest

Fax 6042532328 108 East 35th Avenue

E-mail [email protected] Vancouver, BC V6V 6V6

Date 12/6/2018 Subject Design & Finishes Confirmation

Dear Paul Warwick : Schindler Elevator Corporation would like to thank you for the opportunity to work with Performance Construction Ltd. on this project. Enclosed you will find submittal #2 for your review and approval, which includes 1 copy of the following drawings and brochures.

General layout #L7178 Sheet(s) 1-7 Sub 01

Power Data Sheets

Schindler 3300 Deco Brochure

Schindler Ahead Brochure

NOTE: Please visit the Schindler 3300 showroom HYPERLINK {https://www.schindler3300na.com} to find the following:

- Capabilities & design brochures, installation checklist, layout data and entrance details are located under “Resources”

- Cab configurator, power calculator and Schindler Draw and Spec are located under “Design Tools” Please return this completed submittal along with one (1) complete set of approved drawings by _______________________. NOTE: Manufacturing cannot begin until this submittal is returned.

Please feel free to call me if you have any questions regarding this submittal.

Respectfully submitted, Schindler Elevator Corporation

Rocky Gill Sales Representative

2018-12-11

AMA: Re-visitedpowder-coat finishoptions over primerpainted options, asrecommended bysupplier.

Schindler Elevator Corporation Performance Construction Ltd. 1150-21331 Gordon Way Richmond, BC V6W 1J9

Contact: Rocky Gill Opportunity Number 0200749445

Telephone 7783274068 Project: The Crest

Fax 6042532328 108 East 35th Avenue

E-mail [email protected] Vancouver, BC V6V 6V6

Page 1 of 6

Date 12/6/2018 Subject Design & Finishes Confirmation

Please return this completed submittal along with one (1) complete set of approved drawings by

________________. Simply confirm by initialing on the line to the right of each Design & Finish statement. NOTE: Manufacturing cannot begin until this submittal is returned. Schindler’s 3300 showroom HYPERLINK {https://www.schindler3300na.com} provides an easy-to-use cab configurator to finalize the finished features of your cab. If you use the configurator, please return the results with this submitted.

1 Power supply to be 208 volts - 3 phase, 60 cycles. Enclosed you will find a copy

of our power data for review and approval by your electrical engineer and

electrical contractor.

____________________

Confirm

2 Floor markings for car station, car position indicator and Braille plates will be P,

1, 2, 3, 4, 5.

Available floor markings are

A, B, C, E, F, G, H, I, J, L, M, O, P, R, S, U, UL, LL, PH, SS, RC

-4, -3, -2, -1, 0, 1, 2 ,3, 4, 5, 6, 7, 8

1R, 2R, 3R, 4R

2A, 3A, 4A

2B, 3B, 4B

P1,

*0, *1, *L, *S, *LL

If you prefer alternate markings, please note your desired selections

_____________________________________

____________________

Confirm

AMA: OK

Subject Design & Finishes Confirmation for Opportunity Number 0200749445

Page Page 2 of 6

Date 12/3/2018

3 Main egress floor to be 1.

If you would prefer an alternate main egress, please note your desired

selection_____________________________

NOTE: Where local code requires, an asterisk will be provided to designate the

main egress floor adjacent to the floor marking.

The following markings are available with the floor marking and asterisk on the

same plate: *0,*1, *2, *L and *LL. (see example).

All other main egress markings will require use of the adjacent blank (see

example).

____________________

Confirm

4 Firefighter’s emergency return feature is included with smoke sensors by others.

The primary return floor will be 1.

The alternate return floor will be 2.

If you prefer an alternate return floor(s) please

note _________________________________

____________________

Confirm

5 Hoistway entrances to be as follows:

- Car 1: Front, Two Speed Side Opening, Right hand door opening.

- Door Size: 42" wide x 84" high.

Examples of Typical Configurations: (Center Opening not available on 2100

lb car)

____________________

Confirm

Subject Design & Finishes Confirmation for Opportunity Number 0200749445

Page Page 3 of 6

Date 12/3/2018

6 Hoist beam(s) at top of elevator hoistway to be located as per Schindler layout

drawings with a minimum rated capacity of 7500 lbs and clearly labeled with this capacity.

Hoistway width = 8' 8''

If not accurate change to _________________________

Hoistway depth = 5' 10''

If not accurate change to _________________________

Hoistway overhead = 13' 0''

If not accurate change to _________________________

Pit depth = 5' 0''

If not accurate change to _________________________

Travel = 53' 11''

If not accurate change to _________________________

____________________

Confirm

7 Hoistway entrances including, doors and jambs finish will be:

6 Painted Door(s) : Tupelo Taupe Primer (E098).

Memphis Grey – (P419) Edmonton White – (E081)

Montreal Blue – (P420) Sarasota Yellow – (SW6903)

Havasu Beige – (E053) Tucson Orange – (SW6886)

Napa Burgundy – (E074) Tupelo Taupe Primer – (E098)

Denver Ivy – (E058) Jacksonville Bronze – (E039)

Cleveland Satin – (E035)

____________________

Confirm

AMA: Use Memphis Grey powdercoat finish if tupelo taupe onlycomes as primer paint finish

Subject Design & Finishes Confirmation for Opportunity Number 0200749445

Page Page 4 of 6

Date 12/3/2018

8 Cab type is standard Schindler 3300.

Cab walls to be laminated : Refer to Schindler Standard Plastic Laminate

Finishes brochure.

___Milwaukee Pewter_____________________________

____________________

Confirm

9 Cab ceiling to be - Stainless Steel #4.

____________________

Confirm

10 Handrails to be - Brushed Aluminum.

Handrails – Straight / Flat

____________________

Confirm

11 Cab doors to be Stainless Steel #4.

____________________

Confirm

12 Cab front return and transom to be Stainless Steel #4.

____________________

Confirm

13 Sills to be aluminum.

Platform recess to be 3/8” (10 mm).

Maximum cab weight including floor NOT to exceed 2,315 lbs.

________________

Acknowledge

AMA: OK

AMA: OK to keep as SST

AMA: OK to keep as SST

Subject Design & Finishes Confirmation for Opportunity Number 0200749445

Page Page 5 of 6

Date 12/3/2018

14 Schindler Ahead add-on. Reference Brochure

Sales rep to provide change notice upon request.

IMPORTANT NOTES:

o Hoist beam to be rated for 7,500 lbs. capacity. o Temporary work platform(s) as shown on Sheet 4 is required at the top landing only and must be supplied &

installed by others. o Machine room is not required. The motor is located at the top of the hoistway and the controller is integrated

in the elevator door frame at the top floor. o 208V and 120V electrical disconnects are required at the top floor near the hoistway in a dedicated,

lockable cabinet by others. o 208V and 120V electrical disconnects are required at the top of the hoistway (confirm location with

Schindler field representatives). o In the event of a power failure the elevator is equipped with a battery back-up feature. o Card reader provisions or keyed access lockouts are available, if required. o The interior finishes and design cannot be modified, only the colour of the plastic laminate can be selected

(see brochure and/or colour chain for colour selection). o Maximum floor recess available is 3/8” and maximum weight allowed for flooring is 165 lbs. Flooring to be

supplied and installed by others.

Please confirm/acknowledge each of the items requested and approve the enclosed drawings. Then

return the form and the approved drawings to me. Please feel free to call me if you have any questions

regarding this submittal.

Respectfully submitted

Schindler Elevator Corporation,

Rocky Gill Sales Representative

778-327-4068

[email protected]

Subject Design & Finishes Confirmation for Opportunity Number 0200749445

Page Page 6 of 6

Date 12/3/2018

The following options are available and attractively priced for your consideration. Please note that

if these options are selected after these submittals are returned, the pricing listed below will be

invalid. By selecting any of these options you agree that the contract price will be adjusted

accordingly

Please contact your Schindler representative if you have any additional questions.

Options Price Acceptance

Upgrade entrances from baked

enamel to stainless steel #4

$1,000.00 per Entrance

Upgrade cab walls from plastic

laminate to stainless steel #4

$2,000.00 per Car

Retractable steel pit ladder (Based on

5' 0" Pit Depth)

$1,500.00 per Car

Project #1306 the Crest #1306Date Thursday, June 14th, 2018

Address 106 East 35th Ave

Created By Chris GodlerCreated Thursday, June 14th, 2018

Modified Thursday, July 5th, 2018

Shop Drawing #023

Subject:

Record

Record Name: Shop drawing #023 - Elevator Design & Finish Form

Code: 14-100Drawing Description: Elevator Design & Finish Form

Vendor (Trade): Schindler Required by: 2018-06-28

Submissions

# Received From Trade Sent To ConsultantReceived From Consultant

Review Status

1 2018-06-14 2018-06-14 2018-07-04 Approved

 

Project #1306 the Crest #1306Date Thursday, June 14th, 2018

Address 106 East 35th Ave

Created By Chris GodlerCreated Thursday, June 14th, 2018

Shop-drawings Submittal Log

Record 1

Record Name: Shop drawing #023 - Elevator Design & Finish Form

Code: 14-100Drawing Description: Elevator Design & Finish Form

Vendor (Trade): Schindler Required by: 2018-06-28

Submissions

# Received From Trade Sent To ConsultantReceived From Consultant

Review Status

1 2018-06-14 2018-06-14

 

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jun 18, 2018

SUBMITTAL REVIEWReview is for general compliance with interior design contract documents. Sole responsibility for correctness of dimensions, details, quantities and safety during fabrica-tion and installation shall remain with the

contractor.

NO EXCEPTIONS TAKEN FURNISH WITH CHANGES NOTES AMEND AND RESUBMIT REJECTED

portico design group

By Christine Bauhaus on Jun 27, 2018

2018-06-27

Schindler Elevator Corporation Performance Construction Ltd. 1150-21331 Gordon Way Richmond, BC V6W 1J9

Contact: Rocky Gill Opportunity Number: 0200749445

Telephone 7783274068 Project: The Crest

Fax 6042532328 108 East 35th Avenue

E-mail [email protected] Vancouver, BC V6V 6V6

Date 6/14/2018

Subject Design & Finishes Confirmation Dear Paul Warwick : Schindler Elevator Corporation would like to thank you for the opportunity to work with Performance Construction Ltd. on this project. Enclosed you will find submittal #1 for your review and approval, which includes 1 copy of the following drawings and brochures.

General layout #7178 Sheet(s) 1-7 Sub 00

Power Data Sheets Schindler 3300 Deco Brochure

NOTE: Please visit the Schindler 3300 showroom at www.schindler3300na.com to find the following:

- Capabilities & design brochures, installation checklist, layout data and entrance details are located under “Resources”

- Cab configurator, power calculator and Schindler Draw and Spec are located under “Design Tools” Please return this completed submittal along with one (1) complete set of approved drawings by _______________________. NOTE: Manufacturing cannot begin until this submittal is returned.

Please feel free to call me if you have any questions regarding this submittal.

Respectfully submitted, Schindler Elevator Corporation

Rocky Gill Sales Representative

Schindler Elevator Corporation Performance Construction Ltd. 1150-21331 Gordon Way Richmond, BC V6W 1J9

Contact: Rocky Gill Opportunity Number 0200749445 Telephone 7783274068 Project: The Crest

Fax 6042532328 108 East 35th Avenue E-mail [email protected] Vancouver, BC V6V 6V6 Page 1 of 6 Date 6/14/2018

Subject Design & Finishes Confirmation Please return this completed submittal along with one (1) complete set of approved drawings by

________________. Simply confirm by initialing on the line to the right of each Design & Finish statement. NOTE: Manufacturing cannot begin until this submittal is returned. Schindler’s 3300 showroom at www.schindler3300na.com provides an easy-to-use cab configurator to finalize the finished features of your cab. If you use the configurator, please return the results with this submitted.

1 Power supply to be 208 volts - 3 phase, 60 cycles. Enclosed you will find a copy of our power data for review and approval by your electrical engineer and electrical contractor.

____________________

Confirm

2 Floor markings for car station, car position indicator and Braille plates will be P, 1, 2, 3, 4, 5. Available floor markings are A, B, C, E, F, G, H, I, J, L, M, O, P, R, S, U, UL, LL, PH, SS, RC -4, -3, -2, -1, 0, 1, 2 ,3, 4, 5, 6, 7, 8 1R, 2R, 3R, 4R 2A, 3A, 4A 2B, 3B, 4B P1, *0, *1, *L, *S, *LL If you prefer alternate markings, please note your desired selections _____________________________________

____________________

Confirm

AMA: Approved by Electrical on Shop drawing # 24(Power data sheets)

AMA: OK

Subject Design & Finishes Confirmation for Opportunity Number 0200749445 Page Page 2 of 6 Date 6/14/2018

3 Main egress floor to be 1. If you would prefer an alternate main egress, please note your desired selection_____________________________ NOTE: Where local code requires, an asterisk will be provided to designate the main egress floor adjacent to the floor marking. The following markings are available with the floor marking and asterisk on the same plate: *0,*1, *2, *L and *LL. (see example).

All other main egress markings will require use of the adjacent blank (see example).

____________________

Confirm

4 Firefighter’s emergency return feature is included with smoke sensors by others. The primary return floor will be 1. The alternate return floor will be 2. If you prefer an alternate return floor(s) please note _________________________________

____________________

Confirm

5 Hoistway entrances to be as follows: - Car 1: Front, Two Speed Side Opening, Right hand door opening.

- Door Size: 42" wide x 84" high. Examples of Typical Configurations: (Center Opening not available on 2100 lb car)

____________________

Confirm

AMA: OK

AMA: OK.

AMA: OK

Subject Design & Finishes Confirmation for Opportunity Number 0200749445 Page Page 3 of 6 Date 6/14/2018

6 Hoist beam(s) at top of elevator hoistway to be located as per Schindler layout drawings with a minimum rated capacity of 7500 lbs and clearly labeled with this capacity. Hoistway width = 8' 8'' If not accurate change to _________________________ Hoistway depth = 5' 10'' If not accurate change to _________________________ Hoistway overhead = 12' 7'' If not accurate change to _________________________ Pit depth = 5' 0'' If not accurate change to _________________________ Travel = 53' 9'' If not accurate change to _________________________

____________________

Confirm

7 Hoistway entrances including, doors and jambs finish will be: 6 Painted Door(s) Memphis Grey – (P419) Edmonton White – (E081)

Montreal Blue – (P420) Sarasota Yellow – (SW6903)

Havasu Beige – (E053) Tucson Orange – (SW6886)

Napa Burgundy – (E074) Tupelo Taupe Primer – (E098)

Denver Ivy – (E058) Jacksonville Bronze – (E039)

Cleveland Satin – (E035)

____________________

Confirm

13'-1 1/2"

As noted by interior designeron shop drawing 27

Subject Design & Finishes Confirmation for Opportunity Number 0200749445 Page Page 4 of 6 Date 6/14/2018

8 Cab type is standard Schindler 3300. Cab walls to be laminated : Refer to Schindler Standard Plastic Laminate Finishes brochure. ________________________________

____________________

Confirm

9 Cab ceiling to be - Stainless Steel #4.

____________________

Confirm

10 Handrails to be - Brushed Aluminum.

____________________

Confirm

11 Cab doors to be Stainless Steel #4.

____________________

Confirm

12 Cab front return and transom to be Stainless Steel #4.

____________________

Confirm

13 Sills to be aluminum. Platform recess to be 3/8” (10 mm). Additional cab weight including floor NOT to exceed 2,315 lbs.

________________

Acknowledge

Milaukee Pewter

revised to painted Tupelo Taupe - June 27, 2018

AMA: OK Per interior designercomments on Shop drawing 27

AMA: OK

Subject Design & Finishes Confirmation for Opportunity Number 0200749445 Page Page 5 of 6 Date 6/14/2018

IMPORTANT NOTES:

o Hoist beam to be rated for 7,500 lbs. capacity. o Temporary work platform(s) as shown on Sheet 4 is required at the top landing only and must be supplied &

installed by others. o Machine room is not required. The motor is located at the top of the hoistway and the controller is integrated

in the elevator door frame at the top floor. o 208V and 120V electrical disconnects are required at the top floor near the hoistway in a dedicated,

lockable cabinet by others. o 208V and 120V electrical disconnects are required at the top of the hoistway (confirm location with

Schindler field representatives). o In the event of a power failure the elevator is equipped with a battery back-up feature. o Card reader provisions or keyed access lockouts are available, if required. o The interior finishes and design cannot be modified, only the colour of the plastic laminate can be selected

(see brochure and/or colour chain for colour selection). o Maximum floor recess available is 3/8” and maximum weight allowed for flooring is 165 lbs. Flooring to be

supplied and installed by others. Please confirm/acknowledge each of the items requested and approve the enclosed drawings. Then return the form and the approved drawings to me. Please feel free to call me if you have any questions regarding this submittal.

Respectfully submitted Schindler Elevator Corporation,

Rocky Gill Sales Representative 778-327-4068

[email protected]

Subject Design & Finishes Confirmation for Opportunity Number 0200749445 Page Page 6 of 6 Date 6/14/2018

The following options are available and attractively priced for your consideration. Please note that if these options are selected after these submittals are returned, the pricing listed below will be invalid. By selecting any of these options you agree that the contract price will be adjusted accordingly

Please contact your Schindler representative if you have any additional questions.

Options Price AcceptanceUpgrade entrances from baked enamel to stainless steel #4

$1,000.00 per Entrance

Upgrade cab walls from plastic laminate to stainless steel #4

$2,000.00 per Car

Retractable steel pit ladder (Based on 5' 0" Pit Depth)

$1,500.00 per Car