Siemens CT
Hans Petter PrestbyCato Nilsen
![Page 2: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/2.jpg)
2
SIRETOM (1974) SOMATOM Sensation 64 (2004)
1 slice
in 7 min
Head CT
in 5 s
31 Years of Innovation Leadership
![Page 3: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/3.jpg)
3
Siemens CT at a Glance
� Approx. 2,000 CT systems
manufactured per year
� > 2,600 employees worldwide
� Number 1 market position
in Europe
� Number 2 market position
in the global market
� Leader in product innovations
� Installed Base worldwide:
9,500 systems
![Page 4: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/4.jpg)
4
Multislice CT for All Needs
Cardiology
Special Care
New syngoApplications
EmergingMarketsSpirit
Sensation Cardiac 64
Sensation OpenHybridsBiographSymbia
SOMATOM
SensationSensation 64
Sensation 40
EmotionEmotion 16
Emotion 6
Emotion Duo
Emotion
Life
syngo Workplaces
Definition
![Page 5: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/5.jpg)
5
11 of Top 15 USA Teaching Hospitals use Siemens
Leading the High-end CT market
Source (2005):
![Page 6: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/6.jpg)
6
The Innovation Continues
SOMATOM Sensation
SOMATOM
Sensation 16Leading the 16-slice market
What are the clinical needs?
![Page 7: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/7.jpg)
7
More and More Slices?
4163264
128
256
![Page 8: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/8.jpg)
8
Reasons to Go Beyond 16-slice CT
Greater spatial resolution for
improved differential diagnosis
Improved image quality
without artifacts
Higher temporal resolution
for robust cardiac imaging
Faster volume coverage where
needed, e.g. arterial CTA and PE
![Page 9: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/9.jpg)
9
SOMATOM Sensation 64Take the Lead in CT
![Page 10: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/10.jpg)
10
SOMATOM Sensation 64
Receives World’s Leading Awards
FROST & SULLIVAN “ENABLING
TECHNOLOGY OF THE YEAR“
AWARD
for the first successfully introduced
64-slice CT worldwide
MEDICAL DESIGN OF
EXCELLENCE AWARD (MDEA)
for exceptional image quality,
speed and ease-of-use
Frost & Sullivan: “…an industry standard in high-quality cardiovascular
imaging … has set a benchmark in the development of high-end technologies ”
![Page 11: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/11.jpg)
11
� Unprecedented Image Quality and Detail with z-Sharp Technology
� Fastest Acquisition Speed with 0 MHU STRATON® tube
� Enhanced Workflow and Clinical Performance with Speed4D™ Technology
� Increased Diagnostic Confidence with Broad Portfolio of Advanced Applications
Take the Lead in CT
SOMATOM Sensation 64
<0.4mm
0.33s
4D
syngo
![Page 12: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/12.jpg)
12
Headline
SOMATOM
Sensation 64
with z-Sharp
33 sec for 1570 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.5 sec
120 kV
148 effective mAs
Courtesy of University of Erlangen and University of Tuebingen
![Page 13: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/13.jpg)
13
Headline
SOMATOM
Sensation 64
with z-Sharp
10 sec for 175 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.5 sec
120 kV
120 effective mAs
Courtesy of The CT Clinical Innovation Center, Mayo Clinic / Rochester, USA
![Page 14: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/14.jpg)
14
Headline
0.4 mm lumen
SOMATOM
Sensation 64
with z-Sharp
5 sec for 289 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
120 kV
190 effective mAs
Courtesy of University Medical Center Grosshadern / Munich, Germany
![Page 15: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/15.jpg)
15
Headline
Courtesy of Johns Hopkins Hospital / Baltimore, USA
SOMATOM
Sensation 64
with z-Sharp
8 sec for 500 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
![Page 16: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/16.jpg)
16
Headline
Courtesy of University Medical Center Grosshadern / Munich, Germany
SOMATOM
Sensation 64
with z-Sharp
Triple Rule Out22 sec for 260 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
120 kV
760 effective mAs
HR 95 BPM
![Page 17: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/17.jpg)
17
Headline
SOMATOM
Sensation 64
with z-Sharp
25 sec for 309 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.37 sec
120 kV
513 effective mAs
HR 71 to 78 BPM
Courtesy of University of Tuebingen / Tuebingen, Germany
![Page 18: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/18.jpg)
18
Courtesy of University Medical Center Grosshadern / Munich, Germany
SOMATOM
Sensation 64
with z-Sharp
13 sec for 162 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
120 kV
860 effective mAs
![Page 19: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/19.jpg)
19
Headline
Courtesy of Toyohashi Heart Center / Toyohashi, Japan
3.5 mm Cypher ® Stent
SOMATOM
Sensation 64
with z-Sharp
14 sec for 185 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
120 kV
800 effective mAs
![Page 20: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/20.jpg)
20
Headline
SOMATOM
Sensation 64
with z-Sharp
9 sec for 479 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.33 sec
120 kV
200 effective mAs
Courtesy of University Medical Center Grosshadern / Munich, Germany
![Page 21: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/21.jpg)
21
Headline
Courtesy of The CT Clinical Innovation Center, Mayo Clinic / Rochester, USA
SOMATOM
Sensation 64
with z-Sharp
7 sec for 50 mm
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 1.0 sec
120 kV
90 effective mAs
![Page 22: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/22.jpg)
22
� Unprecedented Image Quality and Detail with z-Sharp Technology
� Fastest Acquisition Speed with 0 MHU STRATON® tube
� Enhanced Workflow and Clinical Performance with Speed4D™ Technology
� Increased Diagnostic Confidence with Broad Portfolio of Advanced Applications
Take the Lead in CT
SOMATOM Sensation 64
<0.4mm
0.33s
4D
syngo
![Page 23: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/23.jpg)
23
Previously Unachievable Image Quality
z-Sharp Technology
� Industry’s highest isotropic resolution of < 0.4 mm (0.33 mm)
� at highest volume coverage
� at any position within the scan field
� with no increase in dose
� Previously unknown sharpness and clarity with complete visible spiral artifact elimination
[Flohr et al, Radiology 2003, 231(P), Flohr et al, RöFo 2004]
![Page 24: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/24.jpg)
24
Industry’s highest isotropic resolution of < 0.4 mm
![Page 25: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/25.jpg)
25
Industry’s highest isotropic resolution of < 0.4 mm
![Page 26: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/26.jpg)
26
Oversampling
0.6 mm
Z
0.6 mm
� 64 slices per rotation
� Routine < 0.4 mm isotropic resolution, with no increase in dose
32 x 0.6 mm
z-Sharp: Double z-Sampling Position 1 & 2
64 ChannelElectronics
![Page 27: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/27.jpg)
27
Industry’s highest isotropic resolution of < 0.4 mm
![Page 28: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/28.jpg)
28
Industry’s highest isotropic resolution of < 0.4 mm
![Page 29: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/29.jpg)
29
Headline
SOMATOM
Sensation 64
with z-Sharp
8 sec for 120 mm
Coronary Stent
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.37 sec
Courtesy of University of Erlangen / Erlangen, Germany
Conventional Technology
Without z-SharpSOMATOM Sensation
With z-Sharp
![Page 30: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/30.jpg)
30
Head Specimen Study: 0.5s, 150mAs, pitch 1.4
Conventional Technology
Without z-Sharp
Previously Unknown Sharpness and Clarity
Complete visible Spiral Artifact Elimination
SOMATOM Sensation
With z-Sharp
SOMATOM
Sensation 64
with z-Sharp
64 x 0.6 mm
Resolution < 0.4 mm
Rotation 0.5 sec
150 effective mAs
![Page 31: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/31.jpg)
31
Headline
SOMATOM
Sensation 64
with z-Sharp
with z-UHR
12 x 0.3 mm
Resolution 0.24 mm
Rotation 1.0 sec
120 kV
Courtesy of University Medical Center Grosshadern / Munich, Germany
![Page 32: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/32.jpg)
32
z-UHR Provides Industry’s Highest Isotropic
Resolution of 0.24 mm
z-UHR Technology
� CATPHAN phantom
measurement
demonstrates that a
isotropic resolution
of 0.24 mm is
clearly visible
0.24 mm
0.25 mm
0.26 mm
z-axis
![Page 33: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/33.jpg)
33
Precondition
for z-Sharp:
Ultra
Fast
Detector
4x1.2mm 4x1.2mm32x0.6mm
Sufficient 28.8 mm z coverage
![Page 34: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/34.jpg)
34
Precondition: Ultra Fast Detector System
![Page 35: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/35.jpg)
35
The Detector Principle
� The Detector acquires
the X-rays and converts
them to visible light
� Photodiodes transform
the light into electrical
signals
� Detector electronics
(DAS) then convert these
electrical signals into
digital Signals
DAS acquires 64 slices
per rotation!
![Page 36: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/36.jpg)
36
Highest Sintilator Efficiency in the MarketComparison of decay time and afterglow
CsJ: Cesium Iodide
YGO: Yttrium Gadolinium Oxide
UFC: Siemens Ultra Fast Ceramic
* Competitive information provided is based on interpretation of available data and may require independent verification
![Page 37: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/37.jpg)
37
The Detector Principle
� The Detector acquires
the X-rays and converts
them to visible light
� Photodiodes transform
the light into electrical
signals
� Detector electronics
(DAS) then convert these
electrical signals into
digital Signals
DAS acquires 64 slices
per rotation!
![Page 38: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/38.jpg)
38
Highest Efficiency and Best Sensitivity with
Siemens Front-Lit Diode
z
![Page 39: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/39.jpg)
39
Photodiodes Transform
Light into Electrical Signals
Competitor A 64 / B 64
Back-Lit Diode- Light cross talk
- Bad sensitivity
- Lowest efficiency
+ No need for bond wires
Siemens Sensation 64
Front-Lit Diode+ No light cross talk
+ Best sensitivity
+ Highest efficiency
- >256-slice density limitation
* Competitive information provided is based on interpretation of available data and may require independent verification
![Page 40: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/40.jpg)
40
2 x 32>
1 x 64
![Page 41: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/41.jpg)
41
� Unprecedented Image Quality and Detail with z-Sharp Technology
� Fastest Acquisition Speed with 0 MHU STRATON® tube
� Enhanced Workflow and Clinical Performance with Speed4D™ Technology
� Increased Diagnostic Confidence with Broad Portfolio of Advanced Applications
Take the Lead in CT
SOMATOM Sensation 64
0.4mm
0.33s
4D
syngo
![Page 42: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/42.jpg)
42
1st2nd3rd1st + 2nd +3rd
Reasons to Go Beyond 0.4 sec RotationFurther Improve Temporal Resolution and Speed
� Conventional approach: multi segment recon + more z-coverage
� Drawback: > 2 segment recon - inadequate for robust cardiac exam.
� Siemens Solution: fastest 0.33 sec rotation + z-Sharp Technology
![Page 43: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/43.jpg)
43
A Paradigm Shift in X-Ray Tube Technology
STRATON X-Ray Tube
� Direct oil cooling of the anode enables extremely high cooling rate of 5.0 MHU/min and compact design
� 0 MHU anode heat storage capacity
Conventional Tube
STRATON X-ray Tube
![Page 44: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/44.jpg)
44
STRATON Competitor A Competitor B Competitor C
5.0 MHU/min 1.7 MHU/min 1.6 MHU/min 1.4 MHU/min
� Industry’s highest cooling rate - app. 3 times faster than competition
� 1/4 the size of competitive x-ray tubes
Smallest Tube Size Enables Fastest Rotation
STRATON X-Ray Tube with 0.33 secCooling Rate
* Competitive information provided is based on interpretation of available data and may require independent verification
![Page 45: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/45.jpg)
45
� Unprecedented Image Quality and Detail with z-Sharp Technology
� Fast Acquisition Speed with 0 MHU STRATON® tube
� Enhanced Workflow and Clinical Performance with Speed4D™ Technology
� Increased Diagnostic Confidence with Broad Portfolio of Advanced Applications
Take the Lead in CT
SOMATOM Sensation 64
<0.4mm
0.33s
4D
syngo
![Page 46: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/46.jpg)
46
When Time is of the Essence
Enhanced Workflow and Performance
Revolution in 3D and 4D Imaging Workflow
�WorkStream4DTM - Direct volume planning with a tenfold
reduction of data
Minimal Dose, Maximum Quality, and Fully Automated
�CARE Dose4DTM - Highest image quality while saving up
to 66 %* dose with realtime mA adjustment
Simplify Your Contrast Workflow
�CARE ContrastTM - One button synchronized scanning and
contrast injection for easy use
* Results May Vary. Data on File.
![Page 47: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/47.jpg)
47
CARE Contrast
� Synchronized scanning and contrast injection
� One button control for easy use
� Ready for future applications using standard interface
Simplify Your Contrast Workflow
![Page 48: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/48.jpg)
48
� Start in the Control Room
�Simplify your routine
� Start in the Scan Room
�Verification of correct I.V.-
Placement
CARE Contrast CT
Simplify Your Contrast Workflow
![Page 49: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/49.jpg)
Picture
Injektron CT2TM
CARE Contrast CT
Supported by Leading Injector Manufacturers
Stellant SXTM (Single)
Stellant DTM (Dual)OptiVantage DHTM
![Page 50: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/50.jpg)
50
Minimal Dose, Maximum Quality, and Fully Automated
CARE Dose4D
%* less Dose
* Results May Vary. Data on File.
![Page 51: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/51.jpg)
51
Slice position
Scan withconstant mAScan with constant mA
500 mA
30 mA
Reduced dose levelbased on topogram
Reduced dose level based on topogram
Real-time angulardose modulation
Real time angular dose modulation
Minimal Dose, Maximum Quality, and Fully Automated
Speed4D – CARE Dose4D
![Page 52: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/52.jpg)
52
Conventional
Workflow
Revolution in 3D and 4D Imaging Workflow
Speed4D – WorkStream4D
![Page 53: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/53.jpg)
53
Revolution in 3D and 4D Imaging Workflow
Speed4D – WorkStream4D
Conventional MSCT Workflow
Workstream4D SOMATOM Sensation Workflow
Save Time and Space
![Page 54: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/54.jpg)
54
![Page 55: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/55.jpg)
55
� Direct 3D planning
and recon.
� Recon Card on
Navigator and Wizard
� Recon. parallel to
scanning
� Double oblique
planning of cardiac
standard views
� Parallel recon. of 24 phases
� HeartView CT Recon Card
on Navigator and Wizard
�Revolution in 3D and 4D Imaging Workflow
Speed4D – WorkStream4D
![Page 56: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/56.jpg)
56
Perform Raw Data Reconstruction at Both Workstations
Speed4D - WorkStream4D
syngo Acquisition
workplacesyngo CT 3D
workplace
Recon. images directly from raw data ensures optimal image quality for all slice planes
![Page 57: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/57.jpg)
57
� Unprecedented Image Quality and Detail with z-Sharp Technology
� Fastest Acquisition Speed with 0 MHU STRATON® tube
� Enhanced Workflow and Clinical Performance with Speed4D™ Technology
� Increased Diagnostic Confidence with Broad Portfolio of Advanced Applications
Take the Lead in CT
SOMATOM Sensation 64
<0.4mm
0.33s
4D
syngo
![Page 58: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/58.jpg)
58
Increased
Diagnostic
Confidence with broad portfolio of
advanced syngo applications
syngo InSpace 4D
� For diagnosis & surgical planning
� One-click Bone removal
� Advancen Vessel Analyses
syngo Circulation**
� One-click heart isolation
� One-click coronary segmentation
� Automatic quantification
of stenoses
� Full evaluation of
left-ventricular function
� Cardio Best Phase
** Available on Leonardo Workplace end of 2005* Results May Vary. Data on File.
![Page 59: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/59.jpg)
59
Tool for Computer Assisted, Automatic Display
of Suspicious Pulmonary Nodules
syngo LungCare
with “NEV”
![Page 60: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/60.jpg)
60
Rapid and Accurate Visualization of Clinically
Significant Colon Polyps and Lesions
syngo ColonographyCT
![Page 61: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/61.jpg)
61
Solution for Stroke Diagnosis
and Brain Tumor Perfusion
syngo Perfusion CT
![Page 62: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/62.jpg)
62
Our vision for
of CTthe future
![Page 63: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/63.jpg)
63
Make CT the first imaging test in
management of CAD patients
![Page 64: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/64.jpg)
64
Establish CT as the standard
choice in acute care
![Page 65: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/65.jpg)
65
Exploring ways to add
new contrasts to CT
![Page 66: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/66.jpg)
66
The World’s First Dual Source CT
![Page 67: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/67.jpg)
67
Excellence in CT
DefinitionSOMATOM
![Page 68: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/68.jpg)
68
SOMATOM DefinitionThe World’s First Dual Source CT
� Faster than Every Beating Heart
� Full Cardiac Detail at Half the Dose
� One-Stop Diagnosis in Acute Care
� Beyond Visualization with Dual Energy
Faster than Every Beating Heart
Full Cardiac Detail at Half the Dose
One-Stop Diagnosis in Acute Care
Beyond Visualization with Dual Energy
![Page 69: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/69.jpg)
69
Faster than Every Beating Heart
All heart rates without ß-Blocker
with constant 83 ms temporal resolution
SOMATOM
DefinitionWorld’s first DSCT
HR independent
temp Res. 83 msec
Rotation 0.33 s
Spatial Res. < 0.4 mm
6 sec for 120 mm
HR 79-86 bpm
Courtesy of University of
Erlangen / Erlangen, Germany
LAD/RCA End Diastolic LAD/RCA End Systolic
![Page 70: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/70.jpg)
70
Faster than Every Beating Heart
All heart rates without ß-Blocker
with constant 83 ms temporal resolution
SOMATOM
DefinitionWorld’s first DSCT
HR independent
temp Res. 83 msec
Rotation 0.33 s
Spatial Res. < 0.4 mm
7 sec for 140 mm
HR 72 bpm
Courtesy of University of
Erlangen / Erlangen, Germany
End Systolic
End Diastolic
![Page 71: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/71.jpg)
71
SOMATOM
DefinitionWorld’s first DSCT
HR independent
temp Res. 83 msec
Rotation 0.33 s
Spatial Res. < 0.4 mm
6 sec for 118 mm
Exposure ~ 5mSv
HR 78 bpm
Courtesy of University of
Erlangen / Erlangen, Germany
Full Cardiac Detail at Half the Dose
Dual Source CT = 1/2 x dose
Single Source
< 55 55-70 70-90 >90 bpm
Dual Source
100%
50%
![Page 72: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/72.jpg)
72
Full Cardiac Detail at Half the Dose
Dual Source CT = 1/2 x Dose
100%
50%
Single Source without ECG Pulsing
Dual Source CTwith Pitch Adaptation and
Adaptive ECG Pulsing
60 70 80 90 100 110 120
x
x
x
Single Source CT
with ECG Pulsing
Heart rate in bpm
Relative Dose
Source: Cynthia McCollough PhD, Mayo Clinic Rochester, USA
RSNA 2005 talk: SSE16-06 / Physics (CT: Cardiac Imaging I) / Monday, Nov 28 2005, 03:50 PM - 04:00 PM, S401AB
* compared with today's most dose-efficient single x-ray tube CT scannersat heart rates above 75 bpm
![Page 73: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/73.jpg)
73
One-Stop Diagnosis in Acute Care
Trauma imaging with 200 cm scan range
and 78 cm bore & FoV
![Page 74: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/74.jpg)
74
One-Stop Diagnosis in Acute Care
ECG-gated 12 s chest pain protocol
without ß-Blocker
![Page 75: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/75.jpg)
75
One-Stop Diagnosis in Acute Care
Most patient sizes with full image quality
and speed utilizing up to 160 kW
SOMATOM
DefinitionWorld’s first DSCT
Rotation 0.33 s
Collimation 0.6 mm
Spatial Res. < 0.4 mm
Spiral Pitch 1.0
Scan Time 33s @ 1994mm
Effective mAs 2 x 150
130 Kg weight
Courtesy of University of
Erlangen / Erlangen, Germany
![Page 76: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/76.jpg)
76
One-Stop Diagnosis in Acute Care
Most patient sizes with full image quality
and speed utilizing up to 160 kW
SOMATOM
DefinitionWorld’s first DSCT
Rotation 0.33 s
Collimation 0.6 mm
Spatial Res. < 0.4 mm
Spiral Pitch 1.5
Scan Time 17s @ 1476mm
Effective mAs 2 x 150
100 Kg weight
Courtesy of University of
Erlangen / Erlangen, Germany
![Page 77: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/77.jpg)
77
Beyond Visualization with Dual Energy
Direct Angio CT
![Page 78: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/78.jpg)
78
SOMATOM
DefinitionWorld’s first DSCT
Rotation 0.5 s
Collimation 0.6 mm
Spatial Res. < 0.4 mm
Spiral Pitch 1.0
Scan Time 5 s @ 300 mm
Dual Energy effective mAs
80 kV, 350mA
140 kV, 150mA
Courtesy of University of
Erlangen / Erlangen, Germany
Beyond Visualization with Dual Energy
Direct Angio CT
![Page 79: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/79.jpg)
79
Beyond Visualization with Dual Energy
Charactarization of tumor tissue
![Page 80: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/80.jpg)
80
Dual Source CT
Beyond Visualization with Dual Energy
140kV
Bone
450 HU Iodine
144 HU
80kVBone
670 HU Iodine
296 HU
![Page 81: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/81.jpg)
81
SOMATOM Definition – The World’s firstPotential New Clinical Applications and Research Areas:
� Direct subtraction of either vessels or bone during scanning
� Characterization of tumor tissue
� Differentiation of body fluids
SOMATOM DefinitionBeyond Visualization with Dual Energy
![Page 82: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/82.jpg)
82
SOMATOM Definition
RSNA abstracts
� Can Dual-Source MDCT Technology Provide 83 ms Temporal
Resolution for Single Segment Recon.of Coronary CT Angio.?Mannudeep Kalra MD
Compared to single source MDCT (165MS temporal resolution for single segment
reconstruction), the dual source MDCT scanner has better temporal resolution of 83
MS for single segment reconstruction of ECG gated CCTA. Faster, dual source
MDCT can improve image quality of CCTA, evaluate patients with higher heart rate in
shorter time, and avoid artifacts from cardiac motion.
Source:
www.rsna.org
� Design of a 64-Slice Dual-Source CT (DSCT) Scanner
Herbert Bruder PhD
Due to the constant temporal resolution of DSCT, which is below 100 ms for all heart
rates, coronary CTA exams can be performed without beta-blockers. Compared to
single source 64-slice MSCT, the fast volume coverage (increased pitch values),
combined with efficient mA modulation, enables cardiac CT examinations at 30-57%
of the radiation dose.
� Dose Performance of a New 64-Channel DSCT ScannerCynthia McCollough PhD
The use of a cardiac wedge filter, 310 ms pulsing window, HR-dependent pitch, and
3-D adaptive filtering allows DSCT to achieve 85 ms temporal resolution – at
equivalent image noise and with a single-segment reconstruction - using only 30 to
57% of the dose of MDCT (factors of 1.7 to 3.0 reduction in dose).
![Page 83: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/83.jpg)
83
Diagnostic Speed and Confidence
CT Clinical Engines
� To achieve the best possible clinical outcomes you need:
�Best possible image quality using the most innovative CT
Technology
�Fast data processing using state-of the-art workflow solutions
�Intuitive, automated clinical software solutions
� The CT Clinical Engines combine exactly these 3 key
components in a single CT solution helping you to achieve
the best possible clinical outcomes
![Page 84: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/84.jpg)
84
� CT Clinical Engines offer you a unique and complete CT
solution for their clinical need
� Seamlessly integrating your diagnostic workflow from
image acquisition through diagnosis and reporting
� Offering you a new level in diagnostic speed and
confidence
Diagnostic Speed and Confidence
CT Clinical Engines
![Page 85: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/85.jpg)
85
syngoWebSpace3D Reading. Wherever You Are
![Page 86: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/86.jpg)
86
How many miles do your customers walk to do 3D reading
for CT?
![Page 87: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/87.jpg)
87
The Idea:
3D Reading. Wherever You Are.
� Anywhere in the healthcare enterprise...
�on the ward
�in the doctor‘s office
�in conference rooms
�in the referring physician’s office
� At home…
�on call duties
�as a second opinion
� While traveling…
�utilize your waiting time on airports
![Page 88: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/88.jpg)
88
� Data transfer from CT scanner to
syngo WebSpace Server in parallel
to Multi Modality Workplace and
PACS
� Real-time streaming from Siemens
CT scanner to syngo WebSpace*
otherwise DICOM streaming
SiemensCT only
� Connect computer to the internet
(≥1Mbit recommended)
� Install plug-in (500kB) on any up-to-
date Windows-Computer
(≥ 1GHz, 512MB RAM)
� Start working with syngo WebSpace
� Temporary thin slice storage on
syngo WebSpace server
� 3D Applications run on
syngo WebSpace server
* Pending 510(k): The information about this product is being provided for planning purposes only.WIP, the information about this product is preliminary. The product is under development and not commercially available in the U.S. and its future availability can not be assured.
![Page 89: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/89.jpg)
89
Enhance Your CT Diagnosis –
Evaluate in Every Dimension
�State of the art 2D, 3D and 4D post processing
tools of our syngo InSpace4D clinical software
solution, e.g.
�MIP and MPR together with advanced 4D
�bone removal
�automated vessel analysis tools
�...
![Page 90: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/90.jpg)
90
Server HW
High Performance ServerUp to 4 VolPros 4GB for high
speed 3D rendering
syngoWebSpace*
3D Reading. Wherever You Are
+
syngo InSpace 4DAll your favorite functions
inc. 4D, Bone Removal, AVA
* Pending 510(k): The information about this product is being provided for planning purposes only.WIP, the information about this product is preliminary. The product is under development and not commercially available in the U.S. and its future availability can not be assured.
![Page 91: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/91.jpg)
91
syngoWebSpace
3D Reading. Wherever You Are
![Page 92: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/92.jpg)
92
� Save your time –
Connect to CT data everywhere
� Enhance your diagnosis –
Read CT images in every dimension
� Add value to your resources –
Turn every PC into a 3D workplace
� Follow your intuition –
Plug and play syngo within your network
syngoWebSpace USP’s
3D Reading. Wherever You Are
![Page 93: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/93.jpg)
93
syngoWebSpace Packages 3D Reading. Wherever You Are
� syngoWebSpace “Clinic”up to 20 concurrent sessions
e.g. for a larger clinic with radiology and cardiology department
� syngoWebSpace “Department”up to 10 concurrent sessions
e.g. for one department in a smaller hospital
� syngoWebSpace “Expert”up to 5 concurrent sessions
e.g. for a radiology or cardiology practice
![Page 94: Siemens CT - Medisinsk teknologisk forening](https://reader030.vdocuments.net/reader030/viewer/2022012723/61b57bf543857a7fa3190ecc/html5/thumbnails/94.jpg)
94
“I'm really excited, about this new product.
Within a matter of seconds
I can connect my laptop to the server and interact with a
routine abdominal or even multiphase cardiac dataset
using full 3D and 4D capabilities.
And this is something that is really going to speed up our
clinical workflow!”
Axel Kuettner, MD, University of Erlangen / Erlangen, Germany