signature hinged doortb (100mm) - suncoast windows · 2018. 10. 29. · sea lant sa rkin g he ad fl...
TRANSCRIPT
Installation Details
SignatureHinged Door TB(100mm)
JAMB FIXING TO SUIT(SEE NOTE)
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
2.2mm STEEL NAIL MIMIMUM.
(BY BUILDER)
STEEL LINTEL
TIMBER LINTEL
SEALANT
SARKING
HEAD FLASHING
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
WHEN FIXING)
REVEAL
(TEMPORARILY PACK
(SEE NOTE)
INTERIOR LINING
ARCHITRAVE
HEAD FIXING TO SUIT
(AT FIXING POINTS)JAMB PACKER
NOTE:
10mm MIN. CLEARANCE
JAMB FLASHING(BY BUILDER)
C
TBSHD_100
1 : 3
DRAWING NO: ISSUE:
SCALE:
PRODUCT NO:
DRAWN:
TB-SIG-HD-02-01 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2014
DATE:
DJH
04/07/14
BRICK VENEER CONSTRUCTION - HEAD & JAMB
Signature Hinged Door TB (100mm )Installation Details
02-01
(TO SUIT)
(AS PER B.C.A.)DRAIN SLOTS
SILL FLASHING
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
(BY BUILDER)
GROUT
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
(AT FIXING POINTS)
INTERIOR LINING
ARCHITRAVE
(NON-SHRINKING)
JAMB STUD
JAMB PACKER
REVEAL
JAMB FIXING TO SUIT
(BY BUILDER)
SARKING
FOOTING
BRICKWORK
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
JAMB FLASHING
INTERNAL FLOOR FINISH
ISSUE:TB-SIG-HD-02-02 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2014
DATE:TBSHD_100
ABN 78 010 409 819
PRODUCT NO:
SCALE: 1 : 3DJHDRAWN:
DRAWING NO:
04/07/14
BRICK VENEER CONSTRUCTION - SILL & JAMB
Signature Hinged Door TB (100mm )Installation Details
02-02
JAMB FLASHING
REVEAL
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
EXTERIOR CLADDING
TIMBER LINTEL
EXTERIOR TRIM
SARKING
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
(BY BUILDER)HEAD FLASHING
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
WHEN FIXING)
INTERIOR LINING
ARCHITRAVE
JAMB STUD
(TEMPORARILY PACK
(SEE NOTE)JAMB FIXING TO SUIT
(BY BUILDER)
NOTE:
10mm MIN. CLEARANCE
HEAD FIXING TO SUIT(SEE NOTE)
C
TBSHD_100
1 : 3
DRAWING NO: ISSUE:
SCALE:
PRODUCT NO:
DRAWN:
TB-SIG-HD-02-03 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2014
DATE:
DJH
04/07/14
CLADDING CONSTRUCTION - HEAD & JAMB
Signature Hinged Door TB (100mm )Installation Details
02-03
A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 20141 : 3
TBSHD_100
DRAWN:
DRAWING NO:
PRODUCT NO:
SCALE:C
ISSUE:
DATE:
DJH
TB-SIG-HD-02-04
04/07/14
CLADDING CONSTRUCTION - SILL & JAMB
GROUT(BY BUILDER)
EXTERIOR TRIM
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
INTERIOR LINING
ARCHITRAVE
JAMB STUD
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
(AT FIXING POINTS)JAMB PACKER
(SEE NOTE)
(BY BUILDER)
SARKING
JAMB FIXING TO SUIT
EXTERIOR CLADDING
(BY BUILDER)
FOOTING
SILL FLASHING
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
JAMB FLASHING
INTERNAL FLOOR FINISH
Signature Hinged Door TB (100mm )Installation Details
02-04
136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2014
PRODUCT NO:
SCALE:
ISSUE:DRAWING NO:
DATE:
TB-SIG-HD-02-05
C
TBSHD_100
1 : 3
A
DJHDRAWN: Phone (07) 3131 3777 Fax (07) 3131 3838
04/07/14
CAVITY BRICK CONSTRUCTION - HEAD & JAMB DETAIL
INTERNAL LINING ADHESIVE
(BY BUILDER)
BRICKWORK
STEEL LINTEL
2.2mm STEEL NAIL MIMIMUM.450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A
HEAD FLASHING(BY BUILDER)
INTERNAL LINING
(TO PINCH FIN)
JAMB FLASHING
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
86133TIE BRICK FLAT TB COM SD
Signature Hinged Door TB (100mm )Installation Details
02-05
PRODUCT NO:
SCALE: Phone (07) 3131 3777 Fax (07) 3131 3838
ISSUE: A
DRAWN:136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2014
TBSHD_100
1 : 3
DRAWING NO: TB-SIG-HDV-02-06
ABN 78 010 409 819
DATE:
DJH
04/07/14
CAVITY BRICK CONSTRUCTION - SILL & JAMB DETAIL
(NON-SHRINKING)GROUT
(BY BUILDER)
JAMB FLASHING
INTERNAL FLOOR FINISH
86133
BRICKWORK
TIE BRICK FLAT TB COM SD
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
INTERNAL LINING
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
INTERNAL LINING ADHESIVE
(BY BUILDER)
FOOTING
ARCHITRAVE
SILL FLASHING
NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
DRAIN SLOTS(AS PER B.C.A.)
Signature Hinged Door TB (100mm )Installation Details
02-06
SCALE:C
136 Zillmere Road, Boondall, Q 4034, AustraliaPhone (07) 3131 3777 Fax (07) 3131 3838DJHABN 78 010 409 819
TBSHD_100
1 : 3
DRAWING NO: ISSUE:TB-SIG-HD-02-07 A
COPYRIGHT 2014DRAWN:
DATE:PRODUCT NO: 04/07/14
BLOCKWORK CONSTRUCTION - HEAD & JAMB DETAIL
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.
BX336 (2304)
(SEAL TO OPENING & FRAME)ANGLE 40 x 25 x 2.7mm
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
ANCHOR FIXING
INTERNAL LINING
(SEE NOTE)BLOCKWORK
FIX ANGLE TO FRAME
INTERNAL LINING ADHESIVE
(SEE NOTE)WITH STAINLESS STEEL RIVETS
REINFORCING BAR
(INISDE ANGLE ONLY - SEE NOTE)
NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRYAND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
Q2481 (2111)ANGLE 25 x 20 x 1.4(SEAL TO OPENING & FRAME)
Signature Hinged Door TB (100mm )Installation Details
02-07
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819 COPYRIGHT 2014
PRODUCT NO:
DRAWING NO:
1 : 3DRAWN:
ISSUE:
SCALE:C
TBSHD_100
TB-SIG-HD-02-08
DATE:
DJH
A
20/11/14
BLOCKWORK CONSTRUCTION - SILL & JAMB DETAIL
(SEAL TO OPENING & FRAME)
(NON-SHRINKING)
(SEAL TO OPENING & FRAME)
INTERNAL FLOOR FINISH
ANGLE 25 x 20 x 1.4
INTERNAL LINING
2.2mm STEEL NAIL MIMIMUM.
INTERNAL LINING ADHESIVE
WITH STAINLESS STEEL RIVETS
TANKING ON ALL OPENING SURFACES(AS PER B.C.A. SEE BELOW)
(SEE NOTE)
300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A
BLOCKWORK
FOOTING
(SEE NOTE)
FIX ANGLE TO FRAME
FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT
GROUT
450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT
Q2481 (2111)
NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRYAND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
BX336 (2304)ANGLE 40 x 25 x 2.7mm
REINFORCING BAR
Signature Hinged Door TB (100mm )Installation Details
02-08
ANGLE 25 x 20 x 1.4(SEAL TO OPENING & FRAME)
PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRYSURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TO
FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
(SEE NOTE)
INTERNAL LINING ADHESIVE
INTERNAL LINING
CONCRETE PANEL
NOTE:
(SEAL TO OPENING & FRAME)ANGLE 40 x 25 x 2.7mm
WITH S.S. RIVETFIX ANGLE TO FRAME
BX336 (2304)
Q2481 (2111)
FIXING TO SUIT(INSIDE ANGLE ONLY - SEE NOTE)
C
TBSHD_100
ABN 78 010 409 819
136 Zillmere Road, Boondall, Q 4034, AustraliaDRAWN:
COPYRIGHT 20141 : 3
DRAWING NO: ISSUE:TB-SIG-HD-02-09 A
Phone (07) 3131 3777 Fax (07) 3131 3838
PRODUCT NO: DATE:
DJH SCALE:
04/07/14
CONCRETE CONSTRUCTION - HEAD & JAMB DETAIL
Signature Hinged Door TB (100mm )Installation Details
02-09
C
TBSHD_100
ABN 78 010 409 819
136 Zillmere Road, Boondall, Q 4034, AustraliaDRAWN:
COPYRIGHT 20141 : 3
DRAWING NO: ISSUE:TB-SIG-HD-02-10 A
Phone (07) 3131 3777 Fax (07) 3131 3838
PRODUCT NO: DATE:
DJH SCALE:
04/07/14
CONCRETE CONSTRUCTION - SILL & JAMB DETAIL
FIX ANGLE TO FRAME
ANCHOR FIXING(INSIDE ANGLE ONLY - SEE NOTE)
PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY
FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.
AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.
INTERNAL LINING
INTERNAL LINING ADHESIVE
SURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TONOTE:
(SEAL TO OPENING & FRAME)ANGLE 40 x 25 x 2.7mm
(SEE NOTE)CONCRETE PANEL
SUBSILL '15' 100BE015 (3353)
(SEAL OVER FIXING HEAD - SEE NOTE)
PACKER
BACKING ROD
URETHANE SEALANT
FIXING TO SUIT
SEAL SUBFRAME
SILL SEALED TO SUBSILL
83353
BX336 (2304)
(SEE NOTE)WITH STAINLESS STEEL RIVETS
Q2481 (2111)ANGLE 25 x 20 x 1.4(SEAL TO OPENING & FRAME)
Signature Hinged Door TB (100mm )Installation Details
02-10
SEAL
2.APPLY SEALANT TO VERTICAL FACE OF DAM ANGLE AND ALSO TO THE FLOOR OF THE SUBSILL.POSITION DAM ANGLE AGAINST STRUCTURE. SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL.
SEAL OVER FIXINGS
DAM ANGLE TO SUIT
BACKING ROD
SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL. SEAL OVER FIXINGS AND UNDER SUB SILL TO STRUCTURE.
(SEAL TO OPENING & SUBSILL)
TANKING APPLIED TO OPENING SURFACE(BY BUILDER)
(TYPE & QUANTITY PROJECT SPECIFIC)SUBSILL FIXING
PACKING AT FIXING POINTS
TANKING APPLIED TO OPENING SURFACE(BY BUILDER)
THEN FIX TO STRUCTURE. SEAL SUBSILL ENDS TO STRUCTURE.1. INSTALL SUBSILL INTO OPENING WITH DAM ANGLE FITTED. PACK SUBSILL LEVEL
(FIT INTO SUBSILL BEFORE FIXING)DAM ANGLE TO SUIT
SUBSILL TO SUIT(SEAL ENDS TO OPENING)
ISSUE:TB-SIG-HD-02-11 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
C COPYRIGHT 2014
DATE:TBSHD_100
ABN 78 010 409 819
PRODUCT NO:
SCALE: 1 : 4DJHDRAWN:
DRAWING NO:
04/07/14
SUBSILL DAM ANGLE INSTALLATION
Signature Hinged Door TB (100mm )Installation Details
02-11
ANGLE 40 x 25 x 2.7mm
BE015 (3353)
(FIXING ANGLE - SEAL TO OPENING & WINDOW)
SUBSILL '15' 100
ANGLE 25 x 20 x 1.4
BX336 (2304)
Q2481 (2111)
83353SEAL SUBFRAME
83611
(SEAL TO OPENING & SUBSILL)ANGLE DAM 100
(TRIM ANGLE - SEAL TO OPENING & WINDOW)
SILICONE SEAL ALL EXPOSED GAPSBETWEEN SUBSILL, DAM ANGLE & ANGLES
C
TBSHD_100
1 : 1.5
DRAWING NO:
PRODUCT NO:
COPYRIGHT 2014DJH SCALE:
ISSUE:TB-SIG-HD-02-12 A
Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia
ABN 78 010 409 819DRAWN:
DATE: 04/07/14
SUBSILL DAM ANGLE INSTALLATION WITHE FIXING & TRIM ANGLES
Signature Hinged Door TB (100mm )Installation Details
02-12