single loop analogue addressable fire control panel
TRANSCRIPT
![Page 1: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/1.jpg)
Single Loop Analogue addressable fire control Panel
![Page 2: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/2.jpg)
Single Loop Fire Control Panel
• 1 Loop not expandable Panel
• Up to 240 devices on the Loop
• LCD Graphic display
• Navigation keys
• System status leds
• 1 Extinguish channel optional card (certified according EN 12094-1)
• Certified according to EN54-4 ed EN54-2 by IMQ
• Low Cost
![Page 3: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/3.jpg)
Single Loop Fire Control Panel
• New generation technology, software selectable protocol
• Up to 240 devices on the Loop
• Self addressing feature
• Up to 2000 m loop length
• Open Line or Loop selectable
• Loop diagnostic feature (detectors contamination level, Loop signal quality, real time value)
• Each device equiped with a short circuit Isolator
![Page 4: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/4.jpg)
Single Loop Fire Control Panel
•1,4 A Switching Power supply
• Thermal compensated battery charger
• Battery supervision (efficiency check)
• 30 Zones
![Page 5: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/5.jpg)
Single Loop Fire Control Panel
•Self restorable fuses protect outputs and battery
•Battery disconnection in case of deep discharge
•24V Output for external devices feed
•Supervised Dialer Output
• 1 A Supervised Alarm Output
• RS485 BUS for up to 4 repeater connection. On each repeater event view and scroll, reset silence etc.
• RS232 port for UP/Downloading
• 1 Supervised + 1 dry contact fault output
![Page 6: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/6.jpg)
Single Loop Fire Control Panel
Using the LCD Graphic display the start up and all the requested programming can be easily done from the front panel
![Page 7: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/7.jpg)
Single Loop Fire Control Panel
Using PC Software a clear indication of Loop devices which report the exact connection sequence is available
With a double click device’s parameters can be accessed
![Page 8: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/8.jpg)
Single Loop Fire Control Panel
Real Time monitor of each device state is available where a wide range of information are reported
![Page 9: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/9.jpg)
Single Loop Fire Control Panel
Up to 8 timers with yearly programming are available
![Page 10: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/10.jpg)
Single Loop Fire Control Panel
Logic equation definable by installer to fulfill each installation requirement
![Page 11: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/11.jpg)
Single Loop Fire Control Panel
•Optional Card for single channel extinguish system management
SMARTLetLoose/ONE
![Page 12: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/12.jpg)
Single Loop Fire Control Panel
•CPD EN12094-1 Approved
![Page 13: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/13.jpg)
Single Loop Fire Control Panel
• 1 supervised input for manual release• 1 supervised input for stop release
• 1 supervised input for pressure switch for baloon supervision and release confirm• 1 supervised output for Pre Extinguish signalling
• 1 supervised output for released signalling
![Page 14: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/14.jpg)
Single Loop Fire Control Panel
•SmartLight/G : Up to 240 loop devices, 30 Zones
•SmartLight/S : up to 64 loop devices, 16 zones
•SmartLetLoose/ONE : single channel gas extinguish management card
![Page 15: Single Loop Analogue addressable fire control Panel](https://reader035.vdocuments.net/reader035/viewer/2022062217/56649e4c5503460f94b41fe5/html5/thumbnails/15.jpg)
THANK YOU