    SITE ANALYZER TOP View

  • 8/14/2019 Site Analyzer

    2/12

    Side view of Site Analyzer

  • 8/14/2019 Site Analyzer

    3/12

    Description of all the Keys Used in site master

    1. Soft KeysActivate the function described directly to the right ofthe key.

    2. Hard Key

    Mode -Activates the mode menu. Use this to select Measure Match,

    Fault Location, Measure Power, or Utilities mode.

    ConfigActivates the configuration menu for the current mode. Usethis to set variable parameters (e.g. frequency band, distance, andunits)

    CalibrateActivates the calibration menu. MarkerActivates the marker menu. Use this to turn markers on or

    off and to move the active marker.

  • 8/14/2019 Site Analyzer

    4/12

  • 8/14/2019 Site Analyzer

    5/12

    6. Cursor Keys

    Left Arrow

    During:

    Data EntryDeletes previously entered data one character at a time.

    Marker UseMoves active marker left one point at a time.

    All other timesAs defined by the function descriptionRight Arrow

    During:

    Marker UseMoves active marker right one point at a time.

    All other timesAs defined by the function description

  • 8/14/2019 Site Analyzer

    6/12

    6. Cursor KeysUp Arrow

    During:Data EntryIncrease the numeric value.

    Marker UseMoves the marker to the maximum trace value.

    While pressing the Contrast keyIncrease the display contrast.

    All other timesAs defined by the function description.

    Down ArrowDuring:

    Data EntryDecrease the numeric value.

    Marker UseMoves the marker to the minimum trace value.

    While pressing the Contrast keyDecrease the display contrast.

    All other timesAs defined by the function description

  • 8/14/2019 Site Analyzer

    7/12

    7. Battery LED

    The Yellow LED lights when the unit is power from an external DC

    power source. It blinks while charging the internal battery. Once the

    battery is fully charged the yellow LED stops blinking. The green LED

    lights whenever the unit is on.

    8. Contrast KeyHold while pressing the up/down arrow keys to adjustthe contrast of the display.

    9. I/O (On/Off)-Turns the instrument on and off. The key must be pressedfor at least onhalf (1/2) second.

  • 8/14/2019 Site Analyzer

    8/12

    Description of Different port in Site master

    Antenna Test PortFemale N connector for connecting to theantenna. Use a phase-stable cable for best results.

    Parallel Printers Port25-pin (DB9) parallel connector for connectingto HP- type inkjet printers. A printer cable is not included.

    Computer/Power Sensor Port9 Pin RS-232 (DB9)serial connector forconnecting to a PC or to Bird power sensors.

    DC InputInput for external power supplies. Plug either the ac powersupply or the cigarette lighter adapter into the dc input. The external

    supplies operate the unit and charge the internal battery.

  • 8/14/2019 Site Analyzer

    9/12

  • 8/14/2019 Site Analyzer

    10/12

    How site analyzer Calibrated

    Step 1- Press the Calibrate key

    Step 2- Connect the Cal Combo Open connector to the unit antennaport.

    Step 3- Press the Open soft key then wait for the unit to beep anddisplay Done.

    Step 4- Connect the Cal Combo Short connector to the unit antennaport.

    Step 5- Press the Short soft key then wait for the unit to beep anddisplay Done.

    Step 6- Connect the Cal Combo Load connector to the unit antennaport.

    Step 7- Press the Load soft key then wait for the unit to beep anddisplay Done.

    Step 8- Remove the Cal Combo from the unit.

  • 8/14/2019 Site Analyzer

    11/12

    How we select the measure match mode

    Step 1- Turn On the Site Analyzer. Press ON/OFF key for second.

    Step 2- Press the MODE key.

    Step 3- Press the Measure Match key.

    Frequencies can be set manually or chosen from a list of presets (band

    lists). If the start, stop, center, or span frequency is manually set, the

    band list will indicate Custom.

  • 8/14/2019 Site Analyzer

    12/12

    How we select the measurement Units

    When making a match measurement, select one of three units for the Y

    (vertical) scale.

    VSWR (ratio)

    Rtn Loss (dB)

    Cbl Loss (dB)