slides
TRANSCRIPT
![Page 1: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/1.jpg)
RFID Systems and Operating Principles
University of HoustonBauer College of BusinessSpring 2007
Presentation Source: RFID Handbook, Chapter 3
![Page 2: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/2.jpg)
Overview
Please read Chapter 3 of the RFID Handbook for this section
RFID Systems can be categorized based on: Operating principles Frequency
![Page 3: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/3.jpg)
CLASSIFICATION BY OPERATING PRINCIPLE
![Page 4: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/4.jpg)
LC Circuit An LC circuit consists of an inductor, represented by the letter L,
and a capacitor, represented by the letter C. When connected together, an electrical current can alternate between them.
The resonance effect occurs when inductive and capacitive reactances are equal. The word resonance refers to a class of phenomena in which a small driving perturbation gives rise to a large effect in the system.
Applications of Resonance: Tuning: LC circuits are set at resonance for a particular carrier frequency Voltage Magnification Current Magnification Load Impedence
![Page 5: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/5.jpg)
![Page 6: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/6.jpg)
Electronic Article Surveillance (EAS)
![Page 7: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/7.jpg)
Why EAS?
RFID = Identification + EAS Shoplifters steal more than US$10 billion a
year from U.S. retailers ($60 billion worldwide)
Shoplifting means: lost sales higher inventory costs tighter margins
![Page 8: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/8.jpg)
1-Bit Transponders
A bit is the smallest unit of information that can have only two states: “1” = “transponder in interrogating zone” “0” = “no transponder in interrogating zone”
![Page 9: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/9.jpg)
EAS system architecture
Reader antenna Security element (tag) Deactivation device Activator device
![Page 10: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/10.jpg)
![Page 11: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/11.jpg)
Radio Frequency
Components: The radio frequency (RF) uses LC resonant
circuits adjusted to a particular frequency Tags: Modern Systems employ coils etched
between foils in the form of a stick-on label
![Page 12: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/12.jpg)
Radio Frequency Operation:
The reader generates a magnetic field in the radio frequency range
When tag is moves into the vicinity of the magnetic alternating field, energy from the alternating field induces voltage in the tag’s coil (Faraday’s Law)
If the frequency of the reader’s field corresponds with the frequency of the tag’s circuit, the tag’s circuit produces a sympathetic oscillation (also starts to oscillate)
![Page 13: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/13.jpg)
Radio Frequency
Operation:
The current that that flows in the tag’s circuit, as a result of the sympathetic oscillation, ultimately acts against its cause – the magnetic field of the reader
This “resistance” leads to a small voltage drop in the reader’s coil and ultimately leads to decrease in magnetic field strength
To ensure better detection rate, the reader may “sweep” across frequencies: 8.2 MHz+- 10%
![Page 14: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/14.jpg)
![Page 15: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/15.jpg)
![Page 16: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/16.jpg)
Radio Frequency
Deactivation Item is placed into deactivator
Deactivator generates a sufficiently high magnetic field that the induced voltage destroys the foil capacitor of the circuit
Capacitors are designed with intentional short-circuit points, called “dimples”
The breakdown of the capacitor is irreversible
![Page 17: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/17.jpg)
Radio Frequency
Problems: The detection rate can be as low as 70%
The detection rate is heavily influenced by certain materials (especially metal) – affect the resonant frequency of the coil
Both reader antenna and tag must have adequate size to ensure adequate data transmission
![Page 18: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/18.jpg)
![Page 19: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/19.jpg)
Microwave
Operation: Exploits the generation of “Harmonics” by components (e.g.
capacitance diodes)
The harmonic of a sinusoidal voltage A with a frequency fA is a sinusoidal voltage B, whose frequency fB is an integer multiple of fA
Tag receives frequency wave from the reader and “multiplies” the frequency and sends it back to the reader
After receiving the “multiplied” frequency signal, the sensor is able to detect the presence of the tag. (E.g. the sensor tuned to the second harmonic triggers alarm when it detects that frequency)
![Page 20: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/20.jpg)
![Page 21: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/21.jpg)
Microwave
Advantages: If the signal is modulated (ASK, FSK), then
interference from other signals can be prevented – the harmonic is also modulated
Microwave EAS systems are less sensitive to metal parts – typical frequencies used are 915 MHz (Europe), 2.45GHz, or 5.6 GHz
Microwave systems are typically used to protect textiles
![Page 22: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/22.jpg)
![Page 23: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/23.jpg)
Frequency Divider
Operation: Operates in the long wave range at 100-135.5 kHz
Tag derives power from the magnetic field; frequency received from the reader is divided by two by the microchip and send back to the reader
The signal is half the original frequency - subharmonic
Signal can be modulated (ASK or FSK) to filter interference
Tag has to be removed from a product after purchase
![Page 24: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/24.jpg)
Electromagnetic EAS Operate using strong magnetic fields in range of10-20kHz
Due to the extremely low frequency, they are the only systems suitable for products containing metal
Signal contains summation of differential frequency of the extra signals by superimposing additional signals with higher frequencies over main signal
The tags are usually in the form of self-adhesive magnetic strips with lengths ranging from 2cm to 20cm
To deactivate: cashier runs a strong permanent magnet along the metal strip magnetization of the element. Can be reactivated any number of times.
However, system performance depends on tag position
![Page 25: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/25.jpg)
![Page 26: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/26.jpg)
Acoustomagnetics Tags come in the form of small, thin plastic boxes
The box contains two metal strips Hard metal strip Strip made from amorphous metal (can vibrate) Ferromagnetic substances are “magnetostrictive” – change in length due
to magnetization
The strip vibrates at high amplitude at resonant frequency of the system
The strip continues to oscillate even after the reader’s field is switched off - like a tuning fork. Hence, itself generates a magnetic alternating field that can be detected by security system higher sensitivity.
To deactivate the tag, it has to be demagnetized
![Page 27: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/27.jpg)
![Page 28: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/28.jpg)
Transmission Procedures
HDX: data transfer from the transponder to the reader alternates with data transfer from the reader to the transponder
FDX: data transfer from the transponder to the reader takes place at the same time as the data transfer from the reader to the transponder
SEQ: transfer of energy from the reader takes place for a limited period of time. Data transfers occur in between these energy pulses
![Page 29: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/29.jpg)
FDX, HDX, SEQ
Source: RFID Handbook
![Page 30: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/30.jpg)
Advantages of SEQ Systems
The available operating voltage is up to twice that of a comparable half/full duplex systems
The energy available to the chip can take, theoretically any value
![Page 31: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/31.jpg)
Inductive coupling
Almost always operated passively
Frequency range used (wavelength): <135 KHz (2400 m), 13.56 MHz (22.1 m)
Components Electronic data-carrying device – Microchip Large coil area – Antenna
![Page 32: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/32.jpg)
Inductive coupling
Operation: Reader’s antenna coil generates a strong EM field, which
penetrates cross-section of coil
Because frequency used is >>> distance between reader and transponder’s antennae, the EM field can be treated as a simple magnetic alternating field Voltage generated by Inductance
Circuit resonates at transmission frequency of reader – very high current generated in reader by resonance step-up which produce required field strengths for operation
The two coils can also be interpreted as a transformer (distance between coils < 0.16 λ – transponder is in Near Field
![Page 33: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/33.jpg)
Inductive coupling
Efficiency of power transfer between reader and transponder is proportional to: Operating frequency Number of windings (higher frequencies need lower windings) Area enclosed by transponder coils Distance between two coils
Data Transfer from Transponder Reader Load Modulation: switching a load resistor on and off at the
transponder’s antenna controlled by data – changes voltage and hence, amplitude
Sensitivity: Two modulation sidebands sent along with main signal (subcarriers), or subharmonics used
![Page 34: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/34.jpg)
Inductive coupling
![Page 35: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/35.jpg)
Electromagnetic backscatter coupling Operated at UHF frequencies: 868 MHz (Europe) and 915 MHz
(USA); and microwave frequencies: 2.5 GHz and 5.8 GHz
Used for long-range systems Gap between reader and transponder > 1m
To achieve ranges of >15m – backscatter transponders have backup batteries to supply power
To maximize battery power, “stand-by” mode used when transponder moves out of range of reader
The battery of an active transponder never provides power for the transmission of data between transponder and reader. Exclusively serves for supply to microchip.
![Page 36: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/36.jpg)
Electromagnetic backscatter coupling Data transmission Reader
Modulated reflection cross-section Efficiency by which objects reflect EM waves – “Reflection
cross-section”. Objects that are in resonance with wave front that hits them have large reflection cross-section
Proportion of incoming power is reflected. The reflection characteristics are influenced by altering the load connected to the antenna in time with the data stream to be transmitted. The amplitude of reflected power is thus modulated
The reader has a “directional coupler” which differentiates between forward and backward signals
![Page 37: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/37.jpg)
Close coupling
Ranges between 0.1 cm – 1 cm
Transponder inserted into reader or placed on marked surface (“touch and go”)
Allows transponder coil to be precisely positioned in air gap of a ring-shaped or U-shaped core
High freq AC in reader generates high freq magnetic field in core and air gap – which provides power supply to chip in transponder
![Page 38: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/38.jpg)
Close coupling
Frequencies in range 1- 10 MHz used
In contrast to inductively coupled or microwave systems, the efficiency of power transfer is very good
Suited for operation of chips with high power consumption – microprocessors (need 10 mW for operation)
Contact-less smart cards – ISO 10536
![Page 39: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/39.jpg)
Close coupling
Data transfer transponder reader Magnetic coupling: Load modulation with
subcarrier used for magnetically coupled data transfer. Frequency and modulation specified in ISO 10536 standard
Capacitive coupling: Plate capacitors in reader and transponders arranged so that they are exactly parallel to one another – defined in ISO 10536
![Page 40: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/40.jpg)
Electrical coupling
Uses electrostatic fields for transmission of energy and data
Load modulation used to transfer data from transponder to reader
![Page 41: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/41.jpg)
Data Transfer from Reader
All known digital modulation procedures used ASK: Amplitude shift keying (most used) FSK: Frequency shift keying PSK: Phase shift keying
![Page 42: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/42.jpg)
CLASSIFICATION BY FREQUENCY
![Page 43: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/43.jpg)
Basic Types of RFID SystemsFrequency Band Characteristics Typical
Applications
Low
100-500 kHz
Short to medium read range, inexpensive, low reading speed
Access control
Animal/Human identification
Inventory Control
Medium
10-15 MHz
Short to medium read range
Potentially inexpensive
Medium reading range
Access Control
Smart Cards
High
UHF: 850-950MHz
Microwave: 2.4 – 5.8 GHz
Long read range
High reading speed
Line of sight required (Microwave)
Expensive
Railroad car monitoring
Toll collection systems
![Page 44: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/44.jpg)
Agenda
13.56MHz RFID Systems (HF) Operating principles are similar to LF
400-1000MHz RFID Systems (UHF)
2.4GHz RFID Systems (Microwave)
![Page 45: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/45.jpg)
How to select an appropriate RFID System? For each application, there is an appropriate RFID system in terms of:
Operating principles Frequency Range Coupling
Functionality Read-only Read-write Motion-detection
Physical form: Stationary readers Handheld Readers Tunnels, Gates
Cost
![Page 46: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/46.jpg)
13.56MHz RFID Systems
Library RFID System from Tagsys
Tag
Circulation Desk Station
Programming Station Security Gate
![Page 47: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/47.jpg)
13.56MHz – Operating Principles Mostly passive – no battery
Low cost Longer life-time
Inductive coupling is used for data transmission
![Page 48: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/48.jpg)
13.56MHz – Operating Principles RF field at 13.56MHz is not absorbed by water or
human tissue
Sensitive to metal parts in the operating zone (this applies to all RFID systems)
As the magnetic field has vector characteristics, tag orientation influences performance of the system (distance) Rotating fields
Since inductive RFID systems are operated in the near field, interference from adjacent systems is lower compared to other systems
![Page 49: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/49.jpg)
13.56MHz - Tags
Tags are available in different shapes and have different functionality
A few turns (<10) of antenna are sufficient to produce a passive tag low cost
![Page 50: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/50.jpg)
13.56MHz –Shape of Tags
ISO Cards (ISO 14443, ISO 15693)
Durable industrial tags
Thin and flexible smart labels
![Page 51: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/51.jpg)
13.56MHz –Functionality
Memory size (from 64 bit - ID tags to several Kbytes)
Memory types: ROM, WORM/OTP, R/RW
Security mechanisms can be implemented
Multi-tag capability – several tags can be read at once
![Page 52: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/52.jpg)
13.56MHz – Readers Range
“Proximity” (<100 mm) Handheld devices, printers, terminals Small size, low cost
“Vicinity” (<1.5m) More complex Higher power consumption
“Medium range” (<400 mm)
![Page 53: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/53.jpg)
13.56MHz –Physical Form of Readers Application
Mobile
Stationary
![Page 54: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/54.jpg)
13.56MHz –Readers
Readers can have several antennas to allow for: Greater operating range Greater volume/area coverage Random tag orientation
![Page 55: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/55.jpg)
13.56MHz – Conveyor Performance A reader that reads 10 to 30 tags per second
Successful tagging of items on a conveyor running at 3 meters/sec and spaced 0.10 m
![Page 56: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/56.jpg)
13.56MHz – Overall Performance Application fit is the key
Memory size, security level
Smaller operating distances allow faster data transmission, longer operating distances impose lower transmission speed
Greater resistance to noise Outside of the ISM band
![Page 57: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/57.jpg)
400-1000 MHz UHF RFID-Systems (UHF)
![Page 58: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/58.jpg)
Uses EM Propagation The amount of energy collected is a function of the aperture of the
receiving antenna, which in simple terms is related to the wavelength of the received signal
Operating range is dependent on the radiant power of the reader, the operating frequency, and the size of a tag antenna
400-1000 MHz UHF RFID-SystemsOperating Principles
![Page 59: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/59.jpg)
400-1000 MHz UHF RFID-SystemsWave Properties EM waves are related to light and behave in a
similar manner
EM waves can be reflected off radio conductive reflective surfaces, refracted as they pass the barrier between dissimilar electric media, or detracted around a sharp edge
UHF waves have shorter waves and, thus, are more effected when passing objects
![Page 60: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/60.jpg)
400-1000 MHz UHF RFID-SystemsPenetration into Liquids EM waves penetrate into different liquids,
depending on the electrical conductivity of the liquid
Water has high conductivity will reflect and absorb the signal
Oil and petroleum liquids have low conductivity will allow EM to pass
![Page 61: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/61.jpg)
400-1000 MHz UHF RFIDRange Read range depends on:
Transmitter (reader) power Energy requirements of the tags (for passive tags) Absorption factor of materials to which the tag is
attached Tag size
The smaller the tag, the smaller the energy capture area, the shorter the read range
![Page 62: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/62.jpg)
400-1000 MHz UHF RFIDInterference Electrical noise from motors, florescent lights,
etc is minimal at UHF
Noise from other RFID systems, mobile phones, etc.
Frequency Hoping Spread Spectrum (FHSS) can reduce interference
![Page 63: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/63.jpg)
400-1000 MHz UHF RFIDRead Direction UHF allows for directional antennas This allows to direct the signal to particular
groups of tags
![Page 64: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/64.jpg)
Orientation of the tag antenna with respect to the reader’s antenna will impact range (not important for some systems)
Tag Orientation
![Page 65: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/65.jpg)
2450 MHz RFID Systems
![Page 66: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/66.jpg)
2450 MHz RFID Systems
Microwave RFID systems have been in wide-spread use for over 10 years in transportation applications Rail car tracking Toll collection Vehicle access control
![Page 67: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/67.jpg)
2450 MHz RFID SystemsOperating Principles Modulated backscatter Microwave systems operate in the “far field” long
range systems
Microwave signals are attenuated and reflected by materials containing water or human tissue and are reflected by metallic objects It is possible to design tags that work on metallic
objects
Line of sight is not required for operations
![Page 68: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/68.jpg)
2450 MHz RFID SystemsOperating Principles UHF and microwave signals easily penetrate wood,
paper, cardboard, clothing, paint, dirt, and similar materials
Because of short wave length and reflective properties of metal, high reading readability can be achieved in metal-intensive environments
Sensitive to orientation Rotating antennas can solve the problem
![Page 69: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/69.jpg)
2450 MHz RFID SystemsOperating Principles UHF and Microwave systems are allocated
many MHz of spectrum independent operation of different systems, less interference
Microwave systems have a proven record of reliability
![Page 70: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/70.jpg)
2450 MHz RFID SystemsPhysical Form of Tags Tags come in various forms
Tags are smaller than their LF and HF counterparts
3 major types of tags EZ pass type Tags for logistical purposes Thin and flexible smart labels
![Page 71: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/71.jpg)
2450 MHz RFID SystemsTags From 64 bits to several Kbytes ROM, OTP, R/RW All required security levels can be realized Multiple tags can be read in the same zone
![Page 72: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/72.jpg)
2450 MHz RFID SystemsReaders “Proximity” “Vicinity” Handheld Stationary
![Page 73: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/73.jpg)
2450 MHz RFID SystemsPerformance Compared to inductive systems, the UHF and
microwave systems can have longer range, higher data rates, smaller antennas, more flexibility in form factors and antenna design
Object penetration and no line-of-sight readability can be better for LF systems
![Page 74: Slides](https://reader033.vdocuments.net/reader033/viewer/2022060111/55631aebd8b42a81528b51a0/html5/thumbnails/74.jpg)
Conclusion
Operating principles impact: Appropriateness of a particular RFID system for a
particular application
Vulnerabilities of RFID systems Interference Security attack