smart energy controller technical guide · web view• suitable for residential, commercial and...

15
Additional wireless power monitor, single phase Additional wireless power monitor, single phase EN-P USER GUIDE Version 1.0 For further details, please contact: Enistic Limited, 4 Isis Business Centre, Pony Road, Oxford, OX4 2RD [email protected] www.enistic.com www.enistic.com Page 1

Upload: others

Post on 30-Jul-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

Additional wireless power monitor, single phase

EN-P

USER GUIDE

Version 1.0

For further details, please contact:

Enistic Limited, 4 Isis Business Centre, Pony Road, Oxford, OX4 2RD

[email protected]

© Copyright 2014 Enistic Limited.

www.enistic.com Page 1

Page 2: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

CONTENTS

Overview...............................................................................................................................................3

Hardware architecture..........................................................................................................................3

Wiring Guide..........................................................................................................................................3

Pairing Transmitter With a Ethernet Receiver – Photograph.................................................................3

Battery Replacement.............................................................................................................................3

Current Transformer Connection – Photograph....................................................................................3

Current Transformers Dimension..........................................................................................................3

Specifications.........................................................................................................................................3

DOCUMENT HISTORY

Version Date Author Notes

1.0 19 Jan 2015 Wasil Ali Preliminary release of alpha test details.

www.enistic.com Page 2

Page 3: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

OVERVIEW

Additional wireless power monitor, single phase (EN-P) is a meter that reads data from current clamps and sends back to the Ethernet wireless receiver (EN112). It is a low cost solution and suitable for office and industrial monitoring applications. EN-P has one input to attach Current Sensor (CT5 – CT3000) supporting readings from devices up to 3000A. It communicates with the controller through the Wireless communications (RF 433MHz ISM band). It comes in a small enclosure and can be mounted on a wall. Simple to Install and easy to configure.

• Suitable for residential, commercial and industrial monitoring purposes.

• Manufactured to comply with IEC 60687/61036/61268 and IEC 62053-21/62053-22/62053-23.

• Single receiver can handle multiple transmitters.

• Plug and play. Easy to install on site.

• Wireless, low power operation.

FEATURES

• Highly accurate design

• Manufactured to comply with international standards IEC 60687/61036/61268 and IEC 62053-21/62053-22/62053-23

• Connects with controller on 433 MHz Band

• Encrypted communications for secure operation

• Good range

ORDER CODES

EN-P - Additional wireless power monitor, single phase

EN126 - Battery 3.6V, AA, 2600mAh

Split core current sensor sizes for EN-P with order code in bold:

EN114 - CT5, EN115 - CT10, EN116 - CT15, EN117 - CT30,

EN118 - CT60, EN119 - CT100, EN120 - CT200, EN121 - CT400,

EN122 - CT600, EN123 - CT1500, EN124 - CT3000

www.enistic.com Page 3

Page 4: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

HARDWARE ARCHITECTURE

Figure 1: Hardware Architecture

Wireless power monitor, single phase is built of a processor and RF transceiver to communicate with

the controller. This device is responsible for taking the readings from Current Clamps and send

readings to the controller via RF link. Frequency off the link is 433MHz. It transmits reading to the

receiver (EN112) every 5 minutes

www.enistic.com Page 4

Page 5: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

WIRING GUIDE

Figure 2: Activity LED “Green”

Figure 3: Current Transformer Connection

Figure 4: Non-Rechargeable Battery

www.enistic.com Page 5

EN-P

Page 6: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

PAIRING TRANSMITTER WITH A ETHERNET RECEIVER – PHOTOGRAPH

In order to pair each transmitter (EN-P) with the receiver (EN112) press the pairing mode button at

the back of the receiver (EN112). During pairing mode the radio activity and server activity LEDs start

flashing for about one minute. While receiver is in pairing mode connect the battery in the

transmitter and wait so that it pairs with the receiver. Once it pairs you will see the radio activity and

server activity LEDs stop flashing.

You need to repeat the above step each time if you have multiple transmitters (EN-P).

Figure 5: Ethernet Receiver Connection Layout

www.enistic.com Page 6

EN112

Page 7: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

www.enistic.com Page 7

Page 8: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

BATTERY REPLACEMENT

Figure 6: Battery Replacement

BATTERY DETAILS Nominal Voltage 3.6V

Nominal Capacity 2.6 Ah (2600mAh)

Nominal Current 2mA

Maximum Continuous Discharge Current 70mA

Battery Weight 17g

Temperature Range –60°C ...+85 °C

Diameter 14.65mm

Length 50.3mm

Order Code: EN126

www.enistic.com Page 8

EN126

Page 9: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

CURRENT TRANSFORMER CONNECTION – PHOTOGRAPH

Figure 7: Current Transformer

Figure 8: Current Transformer Connection

www.enistic.com Page 9

Page 10: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

CURRENT TRANSFORMERS DIMENSION

www.enistic.com Page 10

Page 11: Smart Energy Controller Technical Guide · Web view• Suitable for residential, commercial and industrial monitoring purposes. • Manufactured to comply with IEC 60687/61036/61268

Additional wireless power monitor, single phase

SPECIFICATIONS

ElectricalItem Value UnitBattery for EN-P 3.6 Vdc

Battery Type Lithium Thionyl ChlorideBattery Capacity 2600 mAhPower Consumption (Typical / Maximum)

9 / 250 mW

PhysicalItem Value UnitSize (l x w x h) 110x71x42 mmFitting Wall mountStorage temperature (min -> max) -10 -> +30 °COperation temperature (min -> max) -10 –> 85 °C

Measurements and MetrologyItem Value UnitChannels 1Nominal Current 5-3000* AMin. Current 0* AMin. Current 1% ** 0.05-150* AMax. Current 5-3150* AMax. Current 1% ** 4.95-2850* AProbe Cable Length 1000-1500* mmCommunicationItem Value UnitStandard RF -Frequency 433 MHzMaximum Range between Tx and Rx (LOS) 100 m

Encryption Yes

Miscellaneous and StandardsItem Value UnitCountry of Design / Manufacture UKPackaging Cardboard box

www.enistic.com Page 11