smile beautifully with sustainable aesthetic solutions

6
With Sustainable Aesthetic Solutions Smile Beautifully

Upload: danghanh

Post on 08-Dec-2016

219 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Smile Beautifully With Sustainable Aesthetic Solutions

With Sustainable Aesthetic SolutionsSmile Beautifully

Page 2: Smile Beautifully With Sustainable Aesthetic Solutions

■ Prosthetic Selection and Placement Wide-ranging portfolio of restorative solutions

■ Prosthetic Planning The BellaTek® Encode® Impression System

■ Implant Placement Implant design and surface topography

■ Peri-Implant Health Management The 3i T3® Implant Management System

■ Site Preparation Comprehensive selection of regenerative products

1 Sullivan DY, Sherwood RL, Porter SS. Long-term performance of OSSEOTITE® Implants: A 6-year follow-up. Compendium. 2001 Apr;Vol.22, No.4.

2 Javed F, Romanos GE. The role of primary stability for successful immediate loading of dental implants. A literature review. J Dent. 2010 Aug;38(8):612-20.

3 Fransson C, Lekholm U, Jemt T, Berglundh T. Prevalence of subjects with progressive bone loss at implants. Clinical Oral Implants Research. 2005;16:440–446.

4 Zitzmann NU, Berglundh T. Definition and prevalence of peri-implant diseases. J Clin Perio. 2008;35:286–291.5 Lazzara RJ†, Porter SS†. Platform Switching: A new concept in implant dentistry for controlling post restorative crestal bone levels. Int J Periodontics Restorative Dent. 2006;26:9-17.

† Dr. Lazzara and Dr. Porter have financial relationships with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

Sustainable Aesthetics

›› Clinicians require solutions that can meet the clinical challenge of providing aesthetic outcomes that are sustainable over time.

■ Delayed Osseointegration

Implants lacking a complex surface topography1 and primary stability require more time for osseointegration.2

■ Peri-implantitis The prevalence of implants

experiencing peri-implantitis has been reported in excess of 12%.3,4

■ Crestal Bone Loss Average implant crestal bone

remodeling can exceed 1.5mm following the first year of function, leading to compromised aesthetics.5

Smile Beautifully withSustainable Aesthetic Solutions

BIOMET 3i provides a comprehensive portfolio of surgical and restorative treatment options with SureSealTM Technology to assist in achieving long-term aesthetic results.

Page 3: Smile Beautifully With Sustainable Aesthetic Solutions

■ CAD/CAM BellaTek® Abutments and stock titanium abutments with gold-nitride coating for improved aesthetics vs. an uncoated titanium abutment

■ BellaTek Encode® Healing Abutments provide optimized solutions to clinicians by eliminating the need for implant level impressions.*

Key benefits include:

• Hard-tissue and Soft-tissue Maintenance • Patient Specific Abutment • Traditional Impression or Intraoral Scanning

■ Contemporary Hybrid 3i T3® Implants facilitate sustainable aesthetics through Dual Acid-Etched (DAE) surface technology and integrated platform switching.

■ Endobon® Xenograft Granules

■ OsseoGuard® and OsseoGuard Flex® Membranes

■ RegenerOss® Grafting Materials

BELLATEK CAD/CAM ABUTMENTS

BELLATEK ENCODE HEALING ABUTMENTS

3i T3 TAPERED IMPLANTS

ENDOBON XENOGRAFT GRANULES OSSEOGUARD AND

OSSEOGUARD FLEX MEMBRANES

GINGIHUE® ABUTMENTS

Sustainable Aesthetics Product Portfolio

Manufacturer: Collagen Matrix, Inc., Oakland, NJ

Manufacturer: BIOMET France Sarl.

* Procedure may vary based on patient and clinical variables. Not all cases can be performed without implant level impressions.

Page 4: Smile Beautifully With Sustainable Aesthetic Solutions

■ The BIOMET 3i SureSealTM Connection with Gold-Tite® Screw Technology provides up to 113% greater Certain® Implant/abutment clamping force than an uncoated screw.6

■ Custom restorations with BIOMET 3i UCLA Castable Abutments

■ PEEK & titanium temporary cylinders for soft-tissue sculpting during healing in single or multi-unit cases

■ Studies show implants with the BIOMET 3i integrated platform switching feature demonstrated crestal bone loss as low as 0.37mm.*7 3i T3® Implants incorporate this same feature.

■ The 3i T3 Implant utilizes the proven OSSEOTITE® Surface technology at the coronal aspect of the implant. In a five-year study, the dual acid-etched surface of the OSSEOTITE Implant presented no increased risk of peri-implantitis or soft-tissue complications versus a machined surface.8

6 Suttin Z†, Towse R†. Effect of abutment screw design on implant system seal performance. Presented at the European Association for Osseointegration, 20th Annual Scientific Meeting; October 2012; Copenhagen, Denmark. http://biomet3i.com/Pdf/Posters/P-450_Effect_of_Screw_Design_on_Implant_Seal.pdf

Bench testing: not necessarily indicative of clinical outcomes.7 Östman PO,†† Wennerberg A, Ekestubbe A, Albrektsson T.

Immediate occlusal loading of NanoTite prevail implants: A prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res. 2010 Mar;12(1):39-47.

8 Zetterqvist L††, Feldman S, Rotter B, Vincenzi G, Wennström JL, Chierico A, Stach RM† and Kenealy JN†. A prospective, multicenter, randomized-controlled 5-year study of hybrid and fully etched implants for the incidence of peri-implantitis. J Periodontol 2010 April;81:493-501.

† Dr. Kenealy, Dr. Stach, Mr. Suttin and Mr. Towse contributed to the above research while employed by BIOMET 3i.

† † Dr. Östman and Dr. Zetterqvist have financial relationships with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

* Results are not necessarily typical, indicative or representative of all recipient patients.

PREFORMANCE® PEEK & TITANIUM TEMPORARY CYLINDERS

3i T3 PARALLEL WALLED IMPLANTS

ALLOGRAFT ALLOGRAFT PUTTY

UCLA ABUTMENTSGOLD-TITE SCREW

■ ■ ■ ■

Page 5: Smile Beautifully With Sustainable Aesthetic Solutions

Implant/Abutment

Implant

Screw

SureSealTM TechnologyBIOMET 3i SureSeal technology is designed for seal integrity through the implant/ abutment connection.

■ This is achieved with a combination of the BIOMET 3i patented* Gold-Tite® Screw with the Certain® Internal Connection and precision manufacturing.

9 Byrne D, Jacobs S, O’Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont. 2006 May–Jun;15(3):164-171.

10 Suttin Z,† Towse R,† Cruz J.† A novel method for assessing implant-abutment connection seal robustness. Poster Presentation: Academy of Osseointegration, 27th Annual Meeting; March 2012; Phoenix, AZ.

† Mr. Cruz, Mr. Suttin and Mr. Towse contributed to the above research while employed by BIOMET 3i.

†† Dr. Patrick R. Schmidlin has a financial relationship with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

††† USPTO 6287116 and additional patents pending.* Primary researcher’s PhD fellowship was supported by BIOMET 3i LLC. Aim of study was to develop a customized and standardized measurement device

allowing repetitive non-destruction evaluation of implant leakage. Three implant systems were tested (n=20, 4 of each group, which were negative controls). The research was funded by BIOMET 3i LLC. Poster presentation can be reviewed at: http://biomet3i.com/PDF/Posters/Poster_Al-Jadaa_et_al_GELT.pdf.

** Poster presentation can be reviewed at: http://biomet3i.com/PDF/Posters/P16-Suttin.pdf

■ Gas Enhanced Leakage Test*

Anas Al-Jadaa1, Timo Peltomaki, Thomas Attin1, Patrick R. Schmidlin††

Clin Oral Implants Res. 2013 Dec 16. doi: 10.1111/clr. 12314. [Epub ahead of print]

• Gas Enhanced Leakage Testing (GELT) for implants was carried out by the University of Zurich, Switzerland.

• Twenty samples each of the BIOMET 3i and competitive implant systems were evaluated.

■ Seal Strength Test**

Zach Suttin†, Ross Towse†, Joell Cruz†

• A study assessed the Implant-Abutment Junction (IAJ) seal robustness of industry leading dental implant systems subjected to a dynamic loading test10

Thommen® SPI Astra TechTM Straumann®

3i T3®

Element OsseoSpeedTM Bone Level With DCD®

Dynamic Fluid Leakage Testing (Leak or Fracture)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

MEAN SEAL TEST DATA

Nitrogen Leakage Rate (hPa/min)Saline Leakage (ml)

Astra Tech

Nobel Biocare®

BIOMET 3i

¥ Pre-clinical studies are not necessarily indicative of clinical results.

¥ Pre-clinical studies are not necessarily indicative of clinical results.

■ Implant/abutment seal strength

The combination of the Certain internal connection and the Gold-Tite Screw provides a robust implant/abutment junction (IAJ) interface through exacting tolerances and proprietary technology that generates increased clamping forces.

■ Implant/abutment clamping force

Patented††† Gold-Tite Surface lubrication allows the screw to rotate further, increasing clamping force and maximizing abutment stability.9

Page 6: Smile Beautifully With Sustainable Aesthetic Solutions

ART1258

REV A 05/14

Global Headquarters4555 Riverside DrivePalm Beach Gardens, FL 334101-800-342-5454Outside the U.S.: +1-561-776-6700Fax: +1-561-776-1272www.biomet3i.com

BIOMET 3iEurope, Middle East & AfricaWTC Almeda Park, Ed. 1, Planta 1ªPl. de la Pau, s/n08940, Cornellà de Llobregat(Barcelona) SpainPhone: +34-93-470-55-00Fax: +34-93-371-78-49

EC REP

■ Smile Beautifully ■ Smile Confidently ■ Smile Healthy

For more information regarding Smile TherapyTM System Solutions, please contact your local BIOMET 3i Sales Representative.

BIOMET 3i offers a family of synergistic system solutions to help you and your patients achieve beautiful, confident and healthy smiles.

JoinUs

FollowUs

WatchUs

DownloadIt

3i T3, Bellatek, Certain, Encode, Endobon, Gold-Tite, OsseoGuard, OsseoGuard Flex, OSSEOTITE and RegenerOss are registered trademarks of BIOMET 3i LLC. Providing Solutions - One Patient At A Time, Smile Therapy and SureSeal are trademarks of BIOMET 3i LLC. ©2014 BIOMET 3i LLC. Astra Tech is a trademark of Dentsply. Nobel Biocare is a registered trademark of Nobel Biocare. Straumann is a registered trademark of Straumann Holding AG. Thommen SPI is a registered trademark of Thommen Medical.

All trademarks herein are the property of BIOMET 3i LLC unless otherwise indicated. This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated, or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the product package insert and the BIOMET 3i Website: www.ifu.biomet3i.com.