SVCS-1 Single Zone Control Panel

310mm x 230mm x 120mm GRF plastic.Sealed lead acid batteries.Auto cut off to protect batteries.Relay to provide volt free fault indication.Close/Auto/Open Function. Front of panel keyswitch to control open/close function of actuators/vents (full override priority).Facility to connect smoke heads to automatically reset once smoke has cleared.Upto 72 hour battery back up on mains failure.

Inputs for:Breakglass callpointsSmoke detectorsFire alarm volt free aux. contactsFiremans Override switch

Outputs for:2/3wire 24Vdc actuators up to 2amp*

230 Vac

24 Vdc 2 amp max load ( *Upgradeable to higher amperage with additional batteries)

2 wire polarity inversion or 3 wires drive open drive closeAdjustable 1-100 seconds

VOLTAGE SUPPLY

VOLTAGE OUTPUT ELECTRIC CONNECTIONDRIVE TIME

120 GRF l i I f

Page 3: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

CONTROLS

SVCS-1 Single Zone Control Panel

0V +12 +5 0V WD RD AX1AX2O/CFLT 0V +5 C O nc com no +24 SS+24s

On timeAdjust

150mA TNeut LiveFS1

230V ac in from3amp fused spur.

ENSURE CABINETIS EARTHED INACCORDANCEWITH CURRENTREGULATIONS

FS4

FS2-BATT 1

FS3-BATT 20V OPEN CLOSEU3

OPEN

AUTO

CLOSE

A2A3

A1

B5B6

B4

FIREMANSOVERRIDE

GREY

GREY

GREY

BROWN

BROWN

BROWN

BLACK

BLACK

BLACK

OPEN

AUTO

CLOSE

FIREMANSOVERRIDE

OPEN

AUTO

CLOSE

L1 in

L1 out

L2

SMOKEVENT

0V Connection ONLY to be used forBelimo type Actuators and

Software Version ????*1BEL

To Actuators

Page 4: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

CONTROLS

SVCS-1 Multi Zone Control Panel

72 hour battery back up on mains failure.300mm x 200mm x 150mm IP65 steel enclosure.Sealed lead acid batteries.Auto cut off to protect batteries.Relay to provide volt free fault indication.Close/Auto/Open Function. Front of panel keyswitch to control open/close function of actuators/vents (full overide priority).Facility to connect smoke heads to automatically reset once smoke has cleared.

Each zone has Input for:

Breakglass callpointsSmoke detectorsFire alarm volt free aux. contactsFiremans Override switch

Each zone has Outputs for:2/3wire 24Vdc actuators up to 2amp* load

230 Vac

24 Vdc 2 amp max load ( *Upgradeable to higher amperage with additional batteries)

2 wire polarity inversion or 3 wires drive open drive closeAdjustable 1-100 seconds

VOLTAGE SUPPLY

VOLTAGE OUTPUT ELECTRIC CONNECTIONDRIVE TIME

Page 5: Smoke Control Systems Catalogue 2012

CONTROLS

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

Introduction Smoke Control SystemsÊs PACS (Programmable-Addressable Control System) is an ideal solution to control multiple vents and inputs while reducing cabling and associated costs. With the addition of a small communication board to our existing VCS-S1 control panels the need for need for large multi-zone control panels is no longer required, reducing on average wiring costs by 75%.

FeaturesA Master Controller operates up to 200 outstations as a stand alone system or can be integrated with an existing Fire Alarm System.

Outstations Work autonomously and report their status back to the Master Controller Inputs from Fire Alarm, Break Glass Call Point, Smoke Sensors and Firefighters Override switch. Outputs 24Vdc up to 10 amps for: 2 wire polarity inversion actuators, 3 wire drive open -

drive close actuators, 3 wire drive open hold open actuators or 2 wire solenoid drives

Master Controller Gives the fire officer complete control of the AOV system Ability to override any automatic signals that the outstations have received. Monitors all outstations and display any faults reported.

Outstation36Vdc or 230 Vac 24v 2-10 amp max load 2 wire polarity inversion,drive open hold open or 3 wires drive open drive closeAdjustable 1-100 seconds

VOLTAGE SUPPLYVOLTAGE OUTPUT ELECTRIC CONNECTION

DRIVE TIME

CommsMaster230 Vac 5v / 24v 3 wires data only

n/a

Addressable Control System

Page 6: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

ACTUATORS

K- Series Extra Heavy Duty

For opening and closing vents in facades and roof areas (e.g. bottom hung, top hung, side hung, vertical & horizontal pivot windows)For smoke and heat exhaust (SHEVS) and natural ventilation systems.Suitable for integration with building management systems (BMS / LON / CAN)Soft start and soft load disconnection (electronically controlled)*Synchronized multiple operation without additional control module.

Adaptable to special structural requirementsvia programmable microprocessor(e.g. stroke reduction)

Stepless optimization for smooth operation via adjustment of chain tension.Optional covering profile for uniform design.End position indicator (optional)Fire Test (300ÀC): TÜV-Nord, KH99.7.1

STROKEELECTRICAL CONNECTIONDOUBLE INSULATEDFORCE (PUSH ACTION)OPERATION

SPEEDCURRENT ABSORPTIONPROTECTION CLASS

KS2600mm2core +1*No250-50Npolarityinversion~7.9mm/s0.8AIP32

KSA2600mm2core +3*No300Npolarityinversion~13.1mm/s1.0AIP32

KSA2600mm2core +3*No600-300Npolarityinversion~7.5mm/s1.0AIP32

KSA2800mm2core +3*No300-200Npolarityinversion~13.1mm/s1.0AIP32

KSA2800mm2core +3*No600-200Npolarityinversion~7.5mm/s1.1AIP32

KSA21000mm2core +3*No300-100Npolarityinversion~13.1mm/s1.0AIP32

KSA21000mm2core +3*No600-100Npolarityinversion~7.5mm/s1.1AIP32

Page 7: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre, Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

ACTUATORS

SNTE

FTA 600 - Folding Arm

A robust aesthetically pleaseing automatic door actuator, the FTA600 is more suited to AOV shaft door where the the actuator is highly visable. It can also be used in the free swing mode to operate access doors automatically (additional hardware required).

Technical DataSupply voltage: 19...32 V DCCutoff current when opening: max. 1,25 Awhen closing: max. 0,40 AMax. opening force: 600 NClosing force: 150 NRunning time: approx. 30 secondsProtection class: IP 32Volt free floating contact: max. 50 V, 0,5 ASupplieds c/w cable: approx. 5 m lengthThe actuator arm opens up toan angle of 93°.

PAY ATTENTION TO HEALTH AND SAFTEY !This is an automatic openning and closing devise , when it is used on doows or windows below 2.5 meters ffl care should be taken to provent injury. The enclosed warning sign has to be clearly visable attached at the door or framework.

Additional Electric locks maybe required and can be driven direct from FTA600

Page 8: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

ACTUATORS

S Series - Chain Actuator

230 Vac

450-600-800-1000mm3 core + earthNodrive open - drive close400N (300N for 800-1000mm) ~ 23 mm/s0,8AIP 20

24 Vdc

450-600-800-1000mm2 core (black core not to be used)

Noby polarity inversion400N (300N for 800-1000mm)~ 20 mm/s2AIP 20

VOLTAGE SUPPLY

STROKE ELECTRIC CONNECTIONDOUBLE INSULATEDOPERATIONFORCE (PUSH ACTION)SPEEDCURRENT ABSORPTION (WITH MAX LOAD)

PROTECTION CLASS

Heavy duty actuator with a powerful 400N thrust and strong, double link stainlesssteel chain. Ideal for heavy windows or windows requiring large opening for smoke control or natural ventilation.24Vdc and 230Vac versions are available. Supplied with 2m cable.Standard colours: White (RAL 9010),

Minimum window height when using:Slide Brackets:900mm for 450mm stroke,1200mm for 600mm stroke, 1600mm for 800mm stroke.Pivot Brackets: 450mm for 450mm stroke, 600mm for 600mm stroke, 800mm for 800mm stroke.

Page 9: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

VENTILATION

Flap Type- Roof Ventilator

PL6 - 24 Vdc

100-300mm2 wiresNoby polarity inversion1200 N1.2AIP 54

VOLTAGE SUPPLY

STROKE ELECTRIC CONNECTIONDOUBLE INSULATEDOPERATIONFORCE (PUSH ACTION)CURRENT ABSORPTION (WITH MAX LOAD)

PROTECTION CLASS

The Stirling is an environmentally friendly prod-uct incorporating all the recyclable and sustain-able elements of Aluminium and the efficient thermal properties of Polyamide thermal break technology giving you a high performance ther-mally efficient product. It is the perfect solution for modern day buildings.

Appearance and colours help to determine the prominence, impact and character of a building combining to harmonise or contrast with there surroundings.The Stirling ventilator is available as mill finish aluminium, polyester powder painted to a wide range of BS and RAL colours with Dual Colour options easily accommodated where that little extra special feature is required

PLA - 24 Vdc

300-1000mm2 wiresNoby polarity inversion1000 - 3200N1.4 - 2.8AIP 54

Page 10: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

VENTI-LATORS

CERTICIEL

Page 11: Smoke Control Systems Catalogue 2012

ture

on

oning

ance

Stairwell AOV (System 1 LSV)

Components Description Equipment

e Options Options

o u r s o l u t i o n s f o rGlobal solutions for lighting ,

daily and smoke ventilationUK

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

Page 12: Smoke Control Systems Catalogue 2012

Smoke Control Systems Limited Unit1 Cymbio Business Centre,Northway Lane, Tewkesbury, Glos. GL20 8JGTel:0844 499 6366 Fax:0844 499 6367 Email:[email protected] www.smokecontrolsystems.co.uk

VENT ILAT ION

Louvred - Window Ventilator

24 Vdc

0-90 deg2 coreNoby polarity inversion1200 N0.65 AIP 54

Can be fitted directly into glazing system orbuilders opening.Frameless louvres also available.Certified in accordance with EN 12101-2. For Natural Smoke and Heat ExhaustVentilation systems, NSHEVs. In addition to general ventilation applications we can also supply units for specialist smoke control use.The SmoTec System has been fully tested and certi-fied to EN 12101-2.

Double glazed, louvre windows with thermally broken extruded aluminium frames. The horizontal louvres rotate on pivot bearings linked to a rack and pinion system, which ensures smooth, synchronised operation.With a maximum opening angle of 90 deg, these windows provide a large free area of ventilation compared to a standard windows.

VOLTAGE SUPPLY

STROKE ELECTRIC CONNECTIONDOUBLE INSULATEDOPERATIONFORCE (PUSH ACTION)CURRENT ABSORPTION (WITH MAX LOAD)

PROTECTION CLASS