solar protection relays & energy monitoring | bluelog | egauge | mainspro

15
SOLAR PROTECTION RELAYS & ENERGY MONITORING PRODUCT FEATURES BCJ Controls

Upload: bcj-controls

Post on 22-Jan-2018

67 views

Category:

Devices & Hardware


0 download

TRANSCRIPT

Page 1: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

SOLAR PROTECTION RELAYS&

ENERGY MONITORINGPRODUCT FEATURES

BCJ Controls

Page 4: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

COMAP MAINSPRO PRODUCT FEATURES:

• Flexible supply voltage and measurement range

• Suited for standard DIN rail installation or door-mount

• User friendly interface with easy setting (no software tools needed)

• Simple wiring with removable connectors

• Remote binary communication

• Compact design for installation in restricted spaces

Page 5: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

COMAP MAINSPRO PRODUCT FEATURES:

• Lost of Mains function and history track function (Last 5 events history log)

• Integrated mechanical lock to secure your settings

• Breaker failure protection

• Watchdog relay output

• Increased resolution of frequency protection settings

• Resistance to frequency jumping

Page 6: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

ABB CM-UFD.M33 CHARACTERISTICS

• – Monitoring of voltage and frequency in single-phase and three-phase mains (2-wire, 3-

wire or 4-wire AC systems)

• – Over- and undervoltage, 10-minutes average value as well as over- and

underfrequency monitoring

• – Two-level threshold settings for over-/undervoltage and over-/underfrequency

• – ROCOF monitoring and vector shift detection are configurable

• – Interrupted neutral detection

• – Default settings in accordance with Great Britain Engineering Recommendations

G59/3 and G83/2

Page 7: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

ABB CM-UFD.M33 CHARACTERISTICS

• – True RMS measuring principle

• – All threshold values and tripping delays are adjustable

• – Error memory for up to 99 entries (incl. cause of error, measured value, relative

timestamp)

• – Password setting protection

• – 3 control inputs (e.g. for feedback signal, remote trip)

• – 3 c/o (SPDT) contacts

• – Multiline, backlit LCD display

Page 8: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

COMAP INTELLIPRO PV FEATURES

• Dynamic grid support

• Directional reactive power undervoltage protection

• Many frequency, voltage, and current protections

• Compatible with ComAp PC tools

• Possible to enable the appropriate functions required by your utility

• Detailed history log completely records the nature of mains disturbances including

brown-outs

• Watchdog reporting provides better reliability of the installation

Page 9: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

COMAP INTELLIPRO PV FEATURES

• Advanced online communication notifies instantly of changes in the mains-

connection

• Door-mount possibility with clear graphical display

• Password protection for full security

• Features new Pole Slip protection

• Certified according to IEC 60255, VDE 0126-1-1 and BDEW

• Applicable for requirements of G59/3, G10, G83 and IEEE1547 and VDE-AR-N 4105

Page 10: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

EGAUGE EG3000-016 SPECS:

• 1% Accurate (Compliant to ANSI C12.1)

• Solid State Memory Records:

• 1 second granularity for 10 minutes

• 1 minute average for 1 year

• 15 minute average for 30 years

• Up to 12 Circuits on 3-phases (120V−480V, 50−60Hz).

Page 11: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

EGAUGE EG3000-016 SPECS:

• 3 + N Voltage Inputs to measure reactive power.

• Data can be accessed on a remotely through the in-built web-server. The online

display is updated every second, giving instant data on any load or generation

changes. It records the most recent 30 years of data in the built-in solid-state

memory.

• Web connection - ethernet required (another model is available which uses ethernet

over power - call for details)

• This unit requires specific CTs to function. Get in contact for advice on the ideal set

up.

Page 12: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

BLUE'LOG X-SERIES SPECS

• Supply voltage: 20 - 60 V DC

• Current consumption: typically 5 W

• Operating temperature: -20 - 70°C

• Protection class: IP 20

• Dimensions: 110 x 148 x 63 mm

• Installation:

Wall installation, Top-hat rail installation in electrical distribution board, in control

cabinets

• Modem: Ethernet connection (10 / 100 MBit)

Page 13: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

BLUE'LOG X-SERIES SPECS

• Display/operation:

1 x display (291 x 118 pixels)

3 x LED

2 x operating buttons + 1 directional pad

1 x reset button

3 x DIP switches for bus termination

• Communication:

2 x RS485/RS422 (auto-detection)

1 x CAN

4 x digital/analog inputs (dry contact, S0, voltage input (0 - 24 V, 0 - 1 V, 0 - 100 mV)

current input (0 - 20 mA), PT1000, configurable via software)

4 x digital outputs (open collector max. 60 V/100 mA or voltage output max. 200 mA;

configurable via software)

4 x digital inputs (dry contact, for e.g. ripple control receiver, S0, configurable via software)

Page 14: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

BCJ CONTROLS

• At BCJ Controls we produce Secondary Protection Switchboards with solar

protection relays for Commercial Solar over 30kW grid connections.

• BCJ Controls - commercial solar network protection unit - switchboard

manufacturing including protection relay & anti-islanding and zero export devices

• BCJ Controls is a solar technology company set up by ex-utility industrial sparkies.

Between them they have a large amount of experience in electrical grid protection,

as well as dealing with utilities on a day-to-day basis.

Page 15: Solar Protection Relays & Energy Monitoring | Bluelog | Egauge | MainsPro

VISIT US:

BCJ Controls

2,17 Lorraine St,

Peakhurst NSW Australia

2210

(02) 9534 8465

www.bcjcontrols.com.au