Page 1: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

ANALYSES

+SOLAR STORAGE

Page 2: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

we need

Page 3: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

1996First Western electricity coordination council blackout 2M people affected in 14 states

2MPEOPLE

1996

Second Western electricity coordination

council blackout 7M people affected in US &

Canada

7MPEOPLE

$42-45BEST. COST

2OO1

Summer Power Crisis in CA

$6BEST. COST

2OO3

New England Blackout, 50M people affected,

2O13

SAN JOSEsubstation shooting

1977Lightening causes blackout affecting 1OM people in NY

$3OOMEST. COST

2OO5 Energy Policy Act

2OO7Energy Independence Security Act (smart grid)

2OO9 ExecutiveOrder 13514

1994 2MPEOPLE

lose power in western states

$15MEST. COST

Page 4: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Microgrid:

Page 5: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Renewables

Storage

Local Site

UtilityGrid

Page 6: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

the

Page 7: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

LOW COST RELIABIILTY SECURITY

Page 8: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

GRID OPTIMIZATION ENVIRONMENT REMOTE

LOCATIONS

Page 9: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

our

Page 10: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Quantitative Analysis Qualitative Analysis

Costs involved

Payback period& savings

Resiliency

CO2 emissions

Sustainability Efforts

Microgrid Modeling

Tools Used

HOMER

DER-CAM

ESVT

Page 11: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

our

Page 12: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Gather Data112 months, 15 mins kW & kWh, utility tariff structure

Cleanse the data2

Input Data3into HOMER, DER-CAM & ESVT [simulation results]

Analyze the results4

Compare & contrast outputs5

Page 13: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Feature

Page 14: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

HOMER DER-CAM ESVT

Parent Organization NREL LBL EPRI

Year Launched 2OOO 2OOO 2O13

User Base 1OO,OOO(193 countries)

—(42 countries) —

MOLP

Electrical Loads

Thermal Loads

Model Type Simulation Optimization Optimization

Page 15: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Financial

Page 16: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Energy Charge Demand Charge&

Energy Consumption

Time

Dem

and

(kW

) Peak LoadENERGY CHARGEEnergy Consumption* (Electric Charge/kWh)

DEMAND CHARGEEnergy Consumption* (Electric Charge/kWh)

DEMAND CHARGEPeak Load * Demand Rate ($/kW/month)

Page 17: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Case Study # 1

Northwestern University (NU) is aprivate research university based inEvanston, Illinois, with campuses inEvanston & Chicago, Illinois, SanFrancisco, California and Doha, Qatar.

LOCATION

Evanston, ILFACILITY TYPE

Research University

OWNERSHIP

NPO

Page 18: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Tech Building Visitor’s Center North Campus

SITE SELECTION

Page 19: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Tech Building Visitor’s Center

North Campus

SPACECONSTRAINT

POTENTIALALTERNATIVE

Ideal location for both quantitative &

qualitative benefits, Client’s

Interest.

?

Page 20: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

ANNUAL ENERGY PROFILEVisitor CenterENERGY CONSUMPTION ( kWh)

1,199,374 kWh PEAK LOAD ( kW )

474 kWFLAT ELECTRICITY CHARGE

7.5 cents/kWhDEMAND RATE$4.5O/kW

TOTAL ELECTRICITY CHARGE

$ 1O4,658

COST OF ENERGY (COE)

8.71 cents/kWh

Page 21: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

EN

ER

GY

CO

NS

UM

PTI

ON

AN

ALY

SIS

Daily Profile Seasonal Profile

Yearly Profile

days

hour

s

kW

Page 22: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

HO

ME

R

OU

TPU

T

Page 23: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

DE

R-C

AM

O

UTP

UT

No Storage Suggested

Page 24: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Yearly investments & operational costs (k$)

DE

R-C

AM

O

UTP

UT

Page 25: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

DE

R-C

AM

O

UTP

UT

Annualized Energy Costs (k$)

Page 26: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Optimal Dispatch for Electricity Technologies (January-week)D

ER

-CA

M

OU

TPU

T

Page 27: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

EN

ER

GY

SAV

ING

SEnergy Charges Energy

Savings

SOLAR ONLY(125 KW )

GRID ONLY

SOLAR + STORAGE(175 KW + 400 KW )

Demand Charges Demand Savings

ENERGY CHARGES

$71,913ENERGY SAVINGS

$18,O71DEMAND

CHARGES$14,113

DEMAND SAVINGS

$561

ENERGY CHARGES

$77,2OOENERGY SAVINGS

$12,784DEMAND

CHARGES$14,171

DEMAND SAVINGS

$5O3TOTAL

SAVINGS N/A TOTAL SAVINGS

$

13,287 TOTAL SAVINGS

$

18,632COE/KWH 8.71 CENTS 7.6O

CENTSCOE/KWH 7.1O

CENTSCOE/KWH

ENERGY CHARGES

$71,913ENERGY SAVINGS N/ADEMAND

CHARGES$14,113

DEMAND SAVINGS N/A

Page 28: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

FIN

AN

CIA

LO

UTC

OM

E ASSUMPTIONS

System Size 125 kW 175 kW + 4OO kW

Project Payback 2.7 years 5.7 years

IRR (2O Years) 26.8% 11.6%

NPV $39O,123 $37O,557

CAPEX $O.34M $1.45M

SOLAR ONLY SOLAR + STORAGE

ANCILLARY SERVICES – 400 KW BATTERY

1. ITC Benefit: 3O%2. Discount Rate: 6%3. Demand Charge Escalator: 3%4. Inflation: 2%5. Solar Panel Cost: $1.5/Watt6. Flow Battery Cost: $73O/kWh

1. Arbitrage - NA2. Frequency Regulation:

$34,O8O/year3. Demand Response: $15,526/year

Page 29: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

QU

ALITATIV

E

BE

NE

FITS

Output from Homer

QUANTITY ONLY GRID SOLAR + STORAGE % Change

Carbon di Oxide 758,004 604,586 -20.24%

Sulphur di Oxide 3,286 2,621 -20.24%

Nitrogen Oxides 1,607 1,281 -20.29%

AN

UU

AL

EM

ISS

ION

S

Research Purpose Showcase Sustainability

Page 30: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference
Page 31: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Risks &

Page 32: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

TECHNOLOGY CASH FLOW LOAD UTILITY

Effe

cts

Miti

gatio

n

Actual performance less than optimal

O&M costs more than expected

Customer non-paymentIncentives withheld or need verification

Customer load changes dramatically

Utility changes tariff structure in a way that is unfavorable

Performance guaranteeMeaningful WarrantyEPC with hardware specific experience

Creditworthy customerTransparent incentive programsFor owner: Min. required payments

Customer load changes dramatically

For owner: Specify acceptable

changes to loadin contract

Support a powerful trade organization Faith in the current status-quo utility model

Page 33: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

TECHNOLOGY LOAD

Effe

cts

Miti

gatio

n

Actual performance less than optimal

O&M costs more than expected

Customer load changes dramatically

Performance guaranteeMeaningful WarrantyEPC with hardware specific experience

Customer load changes dramatically

For owner: Specify acceptable

changes to loadin contract

Page 34: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Our

Page 35: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

Importance of analyzing Mission Critical Loads.

COE (Solar + Storage) < COE (Grid)

Page 36: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

microgrids are a viable option

Despite this,

when ITC and ancillary services are considered.

Page 37: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

HOMER & DER-CAM are more sophisticated toolscompared to other tools available in the market. eg: ESVT, etc.

Page 38: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

We learned some

Page 39: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

what makes a

+SOLAR STORAGE MARKET

Higher UtilityTariff RatesGenerally

> $O.1O/kWhDemand Charges

> $12.5/kW/Month

Availability of Ancillary Services

Page 40: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference

DescriptionSolar PV and energy storage savings

are packaged and price as a fixed monthly charge

Energy storage savings accrue to the 3rd party owner, who in turn offers a lower PAA rate

Customer signs a PPA for solar generation and lease or shared savings for energy

storage

Customer Transactio

nOne Bill for the customer

Two Bills: • Energy @ PPA rate• Pass through

a demand savings

Two Bills: • Energy @ PPA rate• Payment for lease or

shared demand savings

Contract Risk Customer Third-party owner Third-party owner

Ability to Finance Easy Moderate Moderate

Common 3rd Party Agreement Types

LEASE SUBSIDIZED PPA DUAL AGREEMENT

Page 41: Solar Storage Analyses by Team NU for Argonne Energy Storage Conference