solenoid valves section level controls & flow switches...

84
7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 How to Use This Catalog . . . . . . . . . . . . . . . . . . . . . . . . .3 Valve Overview Valve Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Solenoid Selection Chart . . . . . . . . . . . . . . . . . . . . . . . .7 Coils Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Part Numbering System . . . . . . . . . . . . . . . . . . . . . . . .9 Body Porting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Housing Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Body Material / Valve Types . . . . . . . . . . . . . . . . . . . . .12 Orifice / Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Coil Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Rectified Coils / Diodes . . . . . . . . . . . . . . . . . . . . . . . .15 Manifold Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Male Bottom Port . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Bottom Port - O Ring Seal . . . . . . . . . . . . . . . . . . . . . .16 Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 3/8" Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Valves with Brazed in Fittings or Tube Ends . . . . . . . . .18 Filters and Screens . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Norgren Jr. Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Electronic / Pneumatic Interface . . . . . . . . . . . . . . . . .20 Norgren Jr. Ordering Information . . . . . . . . . . . . . . . . .21 Norgren Isolation Valves . . . . . . . . . . . . . . . . . . . . . . .22 Selection Criteria for Isolation Valves . . . . . . . . . . . . . .23 Norgren Isolation Valve PIN & Isolation Manifolds . . . .24 Isolation Valve - Back Pressure . . . . . . . . . . . . . . . . . .25 Manifolds Operator Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Isolated Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Manifold Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Acrylic Subplates . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 OEM Design Capabilities . . . . . . . . . . . . . . . . . . . . . .27 Norgren Jr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Cartridge Fitting Inserts . . . . . . . . . . . . . . . . . . . . . . . .28 Standard Manifold Ordering Information . . . . . . . . . . . . .29 Valve Ordering Information 2-Way Normally Open Valves . . . . . . . . . . . . . . . . .30-31 2-Way Normally Closed Valves . . . . . . . . . . . . . . . .32-33 3-Way Normally Closed Valves . . . . . . . . . . . . . . . .34-35 3-Way Multi-Purpose Valves . . . . . . . . . . . . . . . . . .36-37 3-Way Normally Open Valves . . . . . . . . . . . . . . . . .38-39 3-Way Directional Control Valves . . . . . . . . . . . . . .40-41 Value Added Options . . . . . . . . . . . . . . . . . . . . . . . . .42 Dimensions Standard, Norgren Jr.Valve & Mounting Brackets . .43-44 Norgren Jr. Series Manifold . . . . . . . . . . . . . . . . . . . . .45 Electronic/Pneumatic Interface . . . . . . . . . . . . . . . . . .46 Manifold Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .47 Manifold Dimensions Including Cartridge Inserts . . . . .48 Application Considerations Liquid Flow Calculations . . . . . . . . . . . . . . . . . . . . . . .49 Air/Gas Flow Calculations . . . . . . . . . . . . . . . . . . . . . .50 Solenoid Valves Section Liquid Level Switches Background . . . . . . . . . . . . . . . . .51 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Single Point Levels LS 1 Series Level Switch . . . . . . . . . . . . . . . . . . . . . . .53 Mini LS 1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 LS 1 with Slosh Shield . . . . . . . . . . . . . . . . . . . . . . . .54 LS 1 Series Ultra Low Level . . . . . . . . . . . . . . . . . . . .55 LS 1 Sidemount . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 LS 11 Plastic Sidemount . . . . . . . . . . . . . . . . . . . . . . .56 25 BN Series Teflon ® . . . . . . . . . . . . . . . . . . . . . . . . . .57 25 BN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 35 SS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 35 SS Series Sidemount . . . . . . . . . . . . . . . . . . . . . . .58 40 SS Series Sidemount . . . . . . . . . . . . . . . . . . . . . . .59 50 BN Moisture Resistance . . . . . . . . . . . . . . . . . . . . .59 50 BN Series Intermediate . . . . . . . . . . . . . . . . . . . . .60 50 BN Series Large . . . . . . . . . . . . . . . . . . . . . . . . . . .60 50 TT Series - All Teflon ® . . . . . . . . . . . . . . . . . . . . . . .61 50 SS Series - Low Specific Gravity . . . . . . . . . . . . . .62 50 SS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Bottle Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 Externally Mounted Level Control . . . . . . . . . . . . . . . .63 80% High Level Shut Off Switch . . . . . . . . . . . . . . . . .64 80% High Level Shut Off Switch Part Numbers . . . . . .65 Custom Level Controls . . . . . . . . . . . . . . . . . . . . . . . .66 627 Series Miniature Level . . . . . . . . . . . . . . . . . . . . .67 Miniature Multipoint Design . . . . . . . . . . . . . . . . . . . . .68 Standard Multipoint Level . . . . . . . . . . . . . . . . . . . . . .69 Multipoint Design Considerations . . . . . . . . . . . . . . . . .70 Multipoint Options . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 Temperature and Level Control . . . . . . . . . . . . . . . . . .72 Level Controls for 55 Gallon Drums . . . . . . . . . . . . . . .73 Assembly Options Norgren Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74 Float/Switch Assembly . . . . . . . . . . . . . . . . . . . . . . . .75 Norgren Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . .76 1000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .77 2000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .78 3000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .79 5000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .80 Application Sheets Level Switch Inquiry Application Sheet . . . . . . . . . . . .81 Flow Switch Inquiry Application Sheet . . . . . . . . . . . . .82 Valve Inquiry Application Sheet . . . . . . . . . . . . . . . . . .83 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 ®Teflon is a registered trademark of E.I. Dupont De Nemours Co. Level Controls & Flow Switches Section NCA-53 July 1999

Upload: vunhan

Post on 12-Mar-2018

219 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 1Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487

How to Use This Catalog . . . . . . . . . . . . . . . . . . . . . . . . .3Valve Overview

Valve Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Solenoid Selection Chart . . . . . . . . . . . . . . . . . . . . . . . .7Coils Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Part Numbering System . . . . . . . . . . . . . . . . . . . . . . . .9Body Porting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Housing Styles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Body Material / Valve Types . . . . . . . . . . . . . . . . . . . . .12Orifice / Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Coil Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Rectified Coils / Diodes . . . . . . . . . . . . . . . . . . . . . . . .15Manifold Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Male Bottom Port . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Bottom Port - O Ring Seal . . . . . . . . . . . . . . . . . . . . . .16Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173/8" Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Valves with Brazed in Fittings or Tube Ends . . . . . . . . .18Filters and Screens . . . . . . . . . . . . . . . . . . . . . . . . . . .18Norgren Jr. Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Electronic / Pneumatic Interface . . . . . . . . . . . . . . . . .20Norgren Jr. Ordering Information . . . . . . . . . . . . . . . . .21Norgren Isolation Valves . . . . . . . . . . . . . . . . . . . . . . .22Selection Criteria for Isolation Valves . . . . . . . . . . . . . .23Norgren Isolation Valve PIN & Isolation Manifolds . . . .24Isolation Valve - Back Pressure . . . . . . . . . . . . . . . . . .25

ManifoldsOperator Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Isolated Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Manifold Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Acrylic Subplates . . . . . . . . . . . . . . . . . . . . . . . . . . . .27OEM Design Capabilities . . . . . . . . . . . . . . . . . . . . . .27Norgren Jr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Cartridge Fitting Inserts . . . . . . . . . . . . . . . . . . . . . . . .28

Standard Manifold Ordering Information . . . . . . . . . . . . .29Valve Ordering Information

2-Way Normally Open Valves . . . . . . . . . . . . . . . . .30-312-Way Normally Closed Valves . . . . . . . . . . . . . . . .32-333-Way Normally Closed Valves . . . . . . . . . . . . . . . .34-353-Way Multi-Purpose Valves . . . . . . . . . . . . . . . . . .36-373-Way Normally Open Valves . . . . . . . . . . . . . . . . .38-393-Way Directional Control Valves . . . . . . . . . . . . . .40-41Value Added Options . . . . . . . . . . . . . . . . . . . . . . . . .42

DimensionsStandard, Norgren Jr. Valve & Mounting Brackets . .43-44Norgren Jr. Series Manifold . . . . . . . . . . . . . . . . . . . . .45Electronic/Pneumatic Interface . . . . . . . . . . . . . . . . . .46Manifold Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .47Manifold Dimensions Including Cartridge Inserts . . . . .48

Application ConsiderationsLiquid Flow Calculations . . . . . . . . . . . . . . . . . . . . . . .49Air/Gas Flow Calculations . . . . . . . . . . . . . . . . . . . . . .50

Solenoid Valves Section

Liquid Level Switches Background . . . . . . . . . . . . . . . . .51Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Single Point Levels

LS 1 Series Level Switch . . . . . . . . . . . . . . . . . . . . . . .53Mini LS 1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54LS 1 with Slosh Shield . . . . . . . . . . . . . . . . . . . . . . . .54LS 1 Series Ultra Low Level . . . . . . . . . . . . . . . . . . . .55LS 1 Sidemount . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55LS 11 Plastic Sidemount . . . . . . . . . . . . . . . . . . . . . . .5625 BN Series Teflon® . . . . . . . . . . . . . . . . . . . . . . . . . .5725 BN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5735 SS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5835 SS Series Sidemount . . . . . . . . . . . . . . . . . . . . . . .5840 SS Series Sidemount . . . . . . . . . . . . . . . . . . . . . . .5950 BN Moisture Resistance . . . . . . . . . . . . . . . . . . . . .5950 BN Series Intermediate . . . . . . . . . . . . . . . . . . . . .6050 BN Series Large . . . . . . . . . . . . . . . . . . . . . . . . . . .6050 TT Series - All Teflon® . . . . . . . . . . . . . . . . . . . . . . .6150 SS Series - Low Specific Gravity . . . . . . . . . . . . . .6250 SS Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Bottle Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Externally Mounted Level Control . . . . . . . . . . . . . . . .6380% High Level Shut Off Switch . . . . . . . . . . . . . . . . .6480% High Level Shut Off Switch Part Numbers . . . . . .65Custom Level Controls . . . . . . . . . . . . . . . . . . . . . . . .66627 Series Miniature Level . . . . . . . . . . . . . . . . . . . . .67Miniature Multipoint Design . . . . . . . . . . . . . . . . . . . . .68Standard Multipoint Level . . . . . . . . . . . . . . . . . . . . . .69Multipoint Design Considerations . . . . . . . . . . . . . . . . .70Multipoint Options . . . . . . . . . . . . . . . . . . . . . . . . . . . .71Temperature and Level Control . . . . . . . . . . . . . . . . . .72Level Controls for 55 Gallon Drums . . . . . . . . . . . . . . .73

Assembly OptionsNorgren Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74Float/Switch Assembly . . . . . . . . . . . . . . . . . . . . . . . .75

Norgren Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . .761000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .772000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .783000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .795000 Series Flow Switch . . . . . . . . . . . . . . . . . . . . . . .80

Application SheetsLevel Switch Inquiry Application Sheet . . . . . . . . . . . .81Flow Switch Inquiry Application Sheet . . . . . . . . . . . . .82Valve Inquiry Application Sheet . . . . . . . . . . . . . . . . . .83

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84

®Teflon is a registered trademark of E.I. Dupont De Nemours Co.

Level Controls & Flow Switches Section

NCA-53July 1999

Page 2: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

Norgren is proud to offer a complete line of liquid level controlsand flow switches to complement our extensive valve line. You’llfind the same Norgren engineered quality and applicationsexpertise in our level and flow controls as you have in our valves.

Norgren Reliability - Norgren valves, level controls, and flowswitches are the engineer’s choice for critical applications, fromthe complexity of medical diagnostic equipment to the harshestenvironmental conditions. In most applications, Norgren controlswill see millions of cycles before retrofit or replacement isrequired.

Norgren Design Flexibility - From high-end CAD to automatedtaping, special machining and assembly, Norgren can engineercontrols for your valve, level, or flow requirements. Our valves,manifolds, level controls and flow switches are constructed fromstandard, modular components. We can manufacture a nearlyunlimited number of differently configured controls to meet yourdeadlines. Our design flexibility applies not only to the standardunits described in this catalog, but also to a wide variety of“specials”... including one for your application. We can design acontrol product with your choice of material, electrical connection,mounting, porting, or any variety of options.

Norgren Service - After quality, service is the single mostimportant facet on which Norgren has been built. You’ll get on-timedeliveries with lead times that are the shortest in the industry. Thatincludes delivery flexibility to coincide with your inquiries forspecials and prototypes, including technical assistance to help youapply our capabilities to your applications. SERVICE, at a pricethat makes you glad you selected Norgren.

Our nationwide network of representatives is ready to help solveyour solenoid valve, level, and flow control applications now.CALL US TODAY!

Page 3: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 3

How to Use This Catalog

This catalog is conveniently organized into twosections. The first section contains valveinformation. The second section, beginning onpage 53, pertains to level controls and flowswitches.

The valve section of the catalog is organized tofollow the order of the Norgren ProductIdentification Number (PIN) System. TheNorgren PIN System is explained on page 9.Pages 9-14 parallel the order of the numberingsystem, so you can define the Norgren partnumber that meets your requirements as youuse these pages. A glossary of commonly usedvalve terms ends the valves section.

The level controls section of the catalog beginson page 51. Electrical data is followed bydescriptions and specifications of the individuallevel controls. Special level controls, includingbottles, multi-point controls, kits, assembliesand other value-added options complete theextensive line of Norgren level controls.

The flow switch data is found on pages 76-80.This is followed by the application inquirysection on pages 81-83. Norgren’s warranty ison page 84.

Solenoid Valves to Meet Your Design

Design ConsiderationsWhen the operation of your system or process requires the remotecontrol of liquid, air, gases or vacuum, the proper selection of asolenoid valve can make a significant difference in the finalperformance of the machine or process. Norgren solenoid valves,operators and manifolds have the versatility and design features tofulfill all types of applications. Some consideration should be givento the following design parameters to help you with the selectionprocess:

• Valve Type• Media

- Temperature- Lubrication- Cleanliness- Isolation

• Flow Rate• Pressure• Power Consumption• Duty Cycle• Material of Construction• Electrical Termination• Porting• Mounting

Design FlexibilityThe Norgren family of standard solenoid valves, solenoid valveoperators and manifolds provide a broad selection of solutions formost applications. Norgren’s manufacturing and design flexibilitylets you customize the products in this catalog and tailor theproduct to your exact requirements rather than tailor yourrequirements to a standard valve. Even if you don’t find what youneed in the catalog, that doesn’t mean that we can’t do it. Many ofour standard products started out as specialty items for our OEMcustomers.

CommitmentWhile the operation of solenoid valves from one company toanother is similar, Norgren Incorporated distinguishes itself withtotal customer service. From design support in the earliest phasesof your project, to just-in-time deliveries to meet your productionschedule, Norgren works with you as part of your team. So, whenmaking that critical decision, don’t just select a valve, select thevalve company that will become your partner. Select Norgren!

Page 4: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Overview

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/994

Standard Sub-Miniature Solenoid ValvesNorgren offers a complete line of subminiature 2-way and 3-waysolenoid valves. Ideally suited for the remote control of liquid, air, orvacuum.

Valves are available with a broad variety of materials ofconstruction, port sizes, seal selections, termination styles,mounting brackets, pressure and flow capabilities to meet yourmost stringent application requirements.

Our standard valves dimensionally meet the industry standardsfrom mounting holes and ports, to valve sizes and configurations.Norgren offers a wide selection of coil construction and meetsvirtually any voltage requirements.

Norgren is eager to install your fittings, attach your specificterminations to the lead wire or accommodate your uniquemounting or installation requirements.

Norgren Isolation ValvesNorgren Series 1, 2, 6 and the Norgren Jr. valves can be suppliedas a diaphragm seal isolated valve. The models can be supplied asa complete valve, or an operator to be mounted in your own cavity,or as a manifold. The diaphragm seal provides a dry isolatedbarrier for all the metal parts of the solenoid valve, maintaining onlythe seal and valve body (usually plastic), as the only wetted parts.

The diaphragm isolated valve models are available as a 2-waynormally closed valve only. However, if your application requires a3-way, we can adapt two valves on a manifold block to act as a 3-way. For more information and ordering data, please refer to theIsolated Valve section on pages 22-25.

Norgren Jr. SeriesWhen your application calls for a micro miniature valve, (.800 Dia.),low wattage (.65 watts), and great flow (.050 CV), then the NorgrenJr. series offers the right valve for the application. Norgren Jr.’spatented construction generates considerable force from the .65watt coil. Valves are available in brass or stainless steel bodyconstruction as well as an operator or in a manifold mountconfiguration. Additional specifications and ordering data areavailable on pages 19 - 21.

The Norgren Jr. series can be provided with the fitting of yourchoice installed, as well as a large variety of wire termination andprinted circuit board mountings.

Page 5: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Overview

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 5

OperatorsNorgren offers a complete line of solenoid operators forapplications where it is practical to incorporate the cavity orifice intoyour system. Use of solenoid operators facilitates system design,simplifies installation and replacement, and lowers overall costs.Operators are typically used for:• Pilot operation of larger valves• 4-Way valves• Hydraulic and pneumatic cylinders• Manifolds Operators are available for any valve series and anyvalve configuration in the Norgren product line. For cavity detailsand ordering number, consult Norgren.

FDA-Grade Polypropylene Body Valves2- and 3-way, FDA-grade polypropylene body solenoid valves areperfect for beverage dispensing, water purification, medical anddental equipment, welding machines, and control of high puritygases. The valve body is standard with either 1/8" NPTF femaleports or 7/16-20 UNF male ports. It can also be ordered with one ofeach port. Polypropylene body valves offer up to 15% higher flowrates than standard catalog valves. Optional bottom metering andlow watt versions are available.

Norgren FDA-grade polypropylene bodies are available in Series 2valves only. They can be adapted for use with Series 1 and Series3 coils on an OEM basis. When selecting this valve for food service,select ethylene propylene (food grade) seals.

ManifoldsNorgren manifold assemblies simplify complex solenoid valveinstallations into an easy to install complete manifold assembly.

Manifolding allows you to eliminate fittings, tubing and otherpotential leak points, in addition to saving valuable manufacturingand test time. Additionally, by integrating other components such asregulators, pressure switches, gauges, and check valves into theassembly, you can save size and weight.

Manifolding also facilitates troubleshooting, and valve replacementwithout disconnecting lines from the manifold base. This minimizesdowntime. Norgren provides engineering and designrecommendations for the most difficult applications. For moreinformation on manifolds, see pages 26-29.

Page 6: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Capabilities

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/996

Vacuum Service Norgren valves and manifolds are ideal for vacuum service and forthose special 3-way valve applications that require vacuum on oneport and pressure on another port. Valve construction is compatiblewith vacuum systems as high as 106 TORR. When ordering justspecify the valve number you require and note - “FOR VACUUMSERVICE”.

Oxygen Service Norgren valves can be processed for oxygen service; for use in themedical industry, spectro-analysis or other applications requiringO2. These valves are specially cleaned and packaged to becontamination-free. All hydrocarbons are removed. When orderinguse the prefix “Y” in the PIN system. See page 9.

Extended Flow Capabilities Norgren can increase the flow (Cv) capability of any of its valvesby modifying the mechanical and electrical components of thevalve. In many cases the pressure ratings (MOPD) of the valvemust be reduced to achieve the higher flow rate (Cv). When yourflow requirements exceed the catalog ratings, consult Norgren forapplication engineering assistance.

Extended Pressure Ratings Solenoid valves can be modified to increase pressure ratings(MOPD) above the standard ratings listed in the catalog. If agencyapprovals are necessary, consultation with UL and/or CSA isrequired. Consult Norgren with all your design parameters todetermine the feasibility of extending the pressure ratings.

Quiet Valves Solenoid valves have a distinct click that is inherent to their designwhen the two metal parts make contact. Norgren offers a bumperor special plunger design for OEM’s that will provide a metal toelastomer contact, thus muffling the sound. In addition to providingquiet operation, this feature also extends the life of the movingparts. Quiet valves are available on 2-way and 3-way valves, DCvoltage only. Contact Norgren for additional information on ourquiet valve option.

Agency Approvals Norgren products conform to agency approvals such as UL, AGA,CSA and NSF International. The approvals are restricted to certainproducts and specific applications. When any agency endorsementis dictated for an operation, refer to the application inquiry sheetsfor each product specified. The sheets are located in the back ofthe catalog. If additional information is needed, please contactNorgren.

Low Wattage Operators, Valves and ManifoldsNorgren offers the option of low wattage coils,as low as 1.5 watts, on many of our standardvalves. These coils offer high pressure (MOPD)operation at low current levels.

• Available in both 2-Way and 3-Way models inSeries 1, Series 2, and Series 3.

• Orifice sizes from 1/32" to 5/32".• Available in 12VDC and 24VDC.• Refer to Norgren solenoid valve charts for

wattage, pressure ratings and Cv factors.

Norgren Series 1, 2 and 3 offer selectivemodels with wattage ratings from 1.5 watts to 3watts. After reviewing the pressure rating(MOPD) of your particular valve in the partnumber section, you may add an (A) - 1.5watts, (B) - 2.0 watts, (C) - 2.5 watts, or a (D) -3.0 watts as a prefix to the part number. It isimportant to note that there is a reducedpressure rating from the standard when areduced wattage coil is used.

For the OEM, Norgren can design andmanufacture a custom coil to meet your specificflow and pressure requirements at close tostandard pricing.

When 1.5 watts is not low enough, you canselect a valve from the Norgren Jr. product linewhich goes as low as .65 watts while stillmaintaining significant flow and pressurespecifications.

Capabilities

Page 7: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Solenoid Selection Chart

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7

Selecting the Best Solenoid Operator for Your ApplicationFEATURE Series 1 Series 2 Series 3 Series 6 Norgren Jr.Size - Diameter (inches) 1 1 1-3/16 1-5/8 0.80Maximum MOPD (psi) 800 1000 1000 1200 100Vacuum Service Yes Yes Yes Yes YesMax. Cv - Body 0.305 0.305 0.490 0.610 .050Min. Cv - Body 0.030 0.030 0.030 0.035 .035Max. Cv - Stop 0.125 0.140 0.140 0.270 .025Min. Cv - Stop 0.025 0.025 0.025 0.024 .015Power Rating 6 watts 7 watts 7 watts 10 watts .65 wattsLead Wire Gauge 20 AWG/18 AWG 20 AWG/18 AWG 18 AWG 18 AWG 24 AWGLow Wattage Operators to 1.5 Watt Available Available Available N/A Available1/8" NPTF Ports - Body Yes Yes Yes Yes No1/4" NPTF Ports - Body No No Yes Yes No3/8" NPTF Ports - Body No No No Yes No#10 - 32 UNF Ports - Body Yes Yes Yes Yes Yes1/8" NPT or 1/4" NPT Male Bottom Port Yes Yes Yes No NoUL Recognized Yes Yes Yes Yes NoCSA Approved Yes Yes Yes Yes NoGrommet Style Housing Yes Yes Yes Yes YesConduit Style Housing Yes Yes Yes Yes NoSpade Terminal Style - (Standard) No 1/4" 1/4" 1/4" NoSpade Terminal Style - (Options) No 3/16" 3/16" No NoAutomotive Terminal Style No No Yes No NoYoke Style (Open Frame) No Yes Yes No NoSide Metering No No Yes Yes NoBottom Metering Yes Yes No No NoExtended Flow Capabilities Yes Yes Yes Yes YesOperator Mount Manifolds Yes Yes No Yes YesValve Mount Manifolds Yes Yes No Yes YesDiaphragm Isolated Version Yes Yes No Yes Yes

Adapter

Nut

Housing

Stop Orifice

Spring LoadedTop Seal

Coil

Plunger

Spring,Plunger, Rtn

Bottom Seal

Body

Body Orifice

Shading Ring(AC Only)

Guide Assembly

Page 8: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Coils Chart

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/998

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Coils

All standard Norgren valves are supplied with a Class “B” dry tapewound coil construction with 24" black leads, P/N (01) in theordering system, unless otherwise specified.

When using this chart below note the available housing styles andthe series in which coils are available.

The following chart shows all coil options readily available, for otheroptions in OEM quantities consult Norgren. Non-standard voltages,leadwire lengths, other lead wire types and colors, may requireminimum quantities.

* For Class F coils change the second digit to a 2. Consult Norgren for minimum order quantities.** For Class H coils change the second digit to a 3. Consult Norgren for minimum order quantities.*** Full wave rectification - see p.15

Number Housing Series Type Class01 1 - Grommet 1, 2, 3, 6 Standard - dry tape wrapped with leads B**01 2 - Conduit 1, 2, 3, 6 Standard - dry tape wrapped with leads B**41 9 - Slotted 1 Free standing molded with leads B**61 9 - Slotted 2, 3, Free standing molded with leads B**61 3 - Yoke 2, 3 Free standing molded with leads B**41 2 - Conduit 1, 2, 3 Potted with leads B**31 9 - Slotted 2, 3 3/16" Vertical spade B**51 9 - Slotted 2, 3 1/4" Vertical spade B**51 3 - Yoke 2, 3 1/4" Top spade (Available with FWR option***) B**41 1 - Grommet 6 Free standing molded with leads B**41 2 - Conduit 6 Free standing molded with leads B**51 9 - Slotted 6 1/4" Vertical spade B**

Norgren standard voltages:12VDC, 24VDC, 24/60, 120/60, 110/50,220/50, 240/60.

Lead wire type -AWG 20 on Series 1 and 2 AWG 18 on Series 1 and 2 with free standing

molded coilAWG 18 on Series 3 and 6

Coil classification -Class B = 130° C or 266° F Class F = 155° C or 311° F Class H = 180° C or 356° F

*See page 9 for P/N System

Page 9: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Part Numbering System

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 9

Norgren Part Identification Numbering (PIN) System For Valves

The Norgren part number provides informationabout every aspect of the product it represents.The first letter is an optional prefix whichidentifies UL recognized, oxygen or lowwattage. The following numbers identify series,ports, housing style, material, valve function,orifice, seal, coil construction and coiltemperature, in that order. The numerical value

PREFIXES(Optional)P = PassivatedU = UL RecognizedY = Oxygen ServiceA = Low Wattage

- 1.5 WattB = Low Wattage

-2.0 WattC = Low Wattage

-2.5 WattD = Low Wattage

-3.0 WattG = Diaphragm

see page 22-24for ordering

SERIES1 = Series 12 = Series 23 = Series 36 = Series 6

PORT2 = 7/16 - 20 UNF Male (j)3 = 1/8" NPT Male Bottom (a)4 = 1/8" NPTF5 = 1/4" NPTF (b)6 = Manifold Mount (c)7 = #10-32 UNF8 = 3/8" NPT (g)

HOUSING1 = Grommet2 = 1/2" NPT Conduit3 = Yoke (d)7 = Grommet w/bracket8 = Conduit w/bracket9 = Slotted (e)0 = Slotted w/bracket (e)

BODY MATERIAL0 = Stainless Steel1 = Brass3 = Operator7 = Polypropylene (h)

FUNCTION1 = 2WNC2 = 2WNO3 = 3WNCFV4 = 3WNCLC5 = 3WNO6 = 3WMP7 = 3WDC (a)

ORIFICE0 = 1/32"1 = 3/64"2 = 1/16"3 = 5/64"4 = 3/32"5 = 1/8"6 = 5/32"7 = 3/16" (f)8 = 1/4" (f)9 = 3/8" (g)

COIL OPTIONSSee page 8

VOLTAGESee page 8

SEAL01 = Buna02 = Fluorocarbon®

03 = Neoprene®

06 = Polyurethane (2WNC only)08 = Teflon® (2WNC only)12 = Neoprene W®

13 = Ethylene Propylene (EPR(Food Grade)

16 = Chemraz® (k)

(a) = Available in Series 1, 2 & 3.(b) = Available in Series 3 & 6.(c) = Available in Series 1, 2 & 6.(d) = Available in Series 2 & 3 only and must be used

with molded spade coil or free standing moldedcoil with lead wires.

(e) = Slotted housing (used with 31 & 51 spade coiloption), available in Series 2, 3 & 6. Used withmolded coil 61 in Series 2 & 3, and 41 in Series 1.

(f) = Available in Series 3 & 6.(g) = Available in Series 6, 2WNC only.(h) = Available in Series 1, 2 & 3.(i) = Available in Series 2 only.(j) = Available in Series 2, Polypropylene body only.(k) = Available in Series 1 & 2 diaphragm only.

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC

OPTIONAL

for each respective category represents one of multiple options.Where possible, the organization of this Norgren catalog presentsinformation in the order of the part identification number.You mayuse the number as a guide to finding information within thecatalog.

The following chart is the key to understanding the Norgren PartIdentification Number:

Page 10: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Porting

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9910

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Body Porting

When selecting port sizes, the adapter is automatically sized tomatch your body port selection. If you would like any other portingarrangements, contact your Norgren representative for assistance.

SIDE PORTING Type of Porting Series 1 Series 2 Series 3 Series 6 Manifolds1/8" NPTF Yes - Std Yes - Std Yes Yes Yes1/4" NPTF No No Yes Yes Yes3/8" NPTF No No No Yes Yes7/16 - 20 UNF Male No Yes No No No7/16 - 20 UNF Male No Yes No No Now/ 1/8" NPTF Female#10 - 32 UNF Yes Yes Yes Yes Yes1/16 NPTF Yes Yes Yes Yes YesInlet or Outlet Yes Yes Yes Yes YesFemale 1/8" NPTF Yes Yes Yes Yes YesFemale #10 - 32 UNF Yes Yes Yes Yes YesFemale 1/4" NPTF No No Yes Yes Yes“O” Ring Sealing Yes Yes Yes Yes YesDual #10 - 32 UNF Yes Yes Yes Yes NoMale Port Yes with Yes with No Yes with NoManifold Mount 5/16"-24 THD 5/16"-24 THD 1/2" -20 THDMale 1/8" NPT w/ 1/8" NPTF Yes Yes Yes No No-Side Port Brass ONLYMale 1/4" NPT w/ 1/8" NPTF Yes Yes Yes No No-Side Port Brass ONLY

– Standard 180°• 90° porting is available either

right or left.• A third body port can be

added as a gauge port or toaccommodate sampling,switches and transducers, onSeries 3 and Series 6.

BOTTOM PORTING

Type of Porting Series 1 Series 2 Series 3 Series 6 Manifolds1/8" NPTF Yes - Std Yes - Std Yes Yes Yes1/4" NPTF No No Yes Yes YesFemale #10 - 32 UNF Yes Yes Yes No Yes

Adapter Porting

*See page 9 for P/N System

Norgren offers a wide selection of fittings forinstallation in your valve and manifolds. We canoffer these pre-taped and installed in yourvalves or manifolds. For more information, seepages 42-43 or ask Norgren representatives fortechnical information, or send along informationon the fitting of your choice.

Page 11: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Housing Styles

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 11

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Housing Styles

Housings are supplied standard in low carbonsteel with a yellow dichromate finish. ConsultNorgren for other plating or finish options.

Grommet (1) Grommet w/Bracket (7) 1/2" NPT Conduit Conduit w/Bracket (8)

Yoke (3)Slottedw/Spade Coil (9)

Slottedw/Leadwire Coil (9)

Slottedw/Bracket (0)

Inverted Housingw/Optional Bracket Inverted With Leads

OptionalMounting Bracket AN Connector

Other housing styles are available for OEM quantities.Consult Norgren for availability and part numbering.

* See page 9 for P/N System

Page 12: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Body Material / Valve Types

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9912

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Body Material

Norgren offers valve bodies in three standard materials. Brass,430F Stainless Steel, and injection molded Polypropylene. Norgrenalso offers bodies manufactured in 303 Stainless Steel, Aluminum,

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Valve Types

(2WNO) 2-Way Normally OpenValve with two ports, inlet and outlet. Valve is open in a de-energized state,and closes when energized. Valve has one orifice which is located in theend stop.

(2WNC) 2-Way Normally ClosedValve with two ports, inlet and outlet. Valve is closed in a de-energizedstate, and opens when energized. Valve has one orifice which is located inthe body.

(3WNCFV or 3WNCLC) 3-Way Normally ClosedValve with three ports, and two orifices. One orifice is located in the bodyand the other in the end stop. The three ports are the “IN”, “EXHAUST” and“CYLINDER”. When the valve is de-energized, the inlet is closed and theexhaust is open. When the valve is energized, the inlet is open allowingflow to the cylinder port and the exhaust orifice is blocked. 3-Way NormallyClosed Valves are available in Line Connect style (with piping adapter),and Free Vent style for exhaust to atmosphere.

(3WMP) 3-Way Multi-PurposeValve with three ports, and two orifices. One orifice is located in the bodyand the other in the end stop. The three ports are the “NORMALLY OPEN”,“NORMALLY CLOSED” and “COMMON”. When the valve is de-energized,the normally closed port is closed and the common port is open to thenormally open port. When the valve is energized, the normally closed portis open allowing flow from the common port and the normally open orificeis blocked. 3-Way Multi-Purpose Valves can be used as a 3WNC, 3WNO,or a 3WDC valve. Additionally, valve can be used to pipe the alternate flowof two different media to one port.

(3WNO) 3-Way Normally OpenValve with three ports, and two orifices. One orifice is located in the bodyand the other in the end stop. The three ports are the “IN”, “EXHAUST” and“CYLINDER”. When the valve is de-energized, the inlet is open to thecylinder port and the exhaust is closed. When the valve is energized, theexhaust is open allowing flow from the cylinder port and the inlet orifice isblocked.

(3WDC) 3-Way Directional ControlValve with three ports, and two orifices. One orifice is located in the bodyand the other in the end stop. The three ports are the “NORMALLY OPEN”,“NORMALLY CLOSED” and “IN”. When the valve is de-energized, the inletis open to the normally open port. When the valve is energized, thenormally closed port is open allowing flow from the inlet port and thenormally open orifice is blocked. 3-Way Directional Control valve can beused to divert flow from one port to another.

Delrin®, PVC or other materials for OEMapplications.

OUT

IN IN

OUTINOUTIN

EXH

IN CYL

EXH

IN CYL

N.O.

N.C. COM

N.O.

N.C. COM

IN

EXH CYL

IN

EXH CYL

N.O.

N.C. IN

N.O.

N.C. IN

Page 13: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Orifice / Seals

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 13

Orifice

Norgren offers standard-sized body orificesfrom 1/32" to 5/32" for Series 1 through 6.Series 3 and 6 orifices are also available up to1/4". We also offer a 3/8" body orifice in Series 6.

Standard end stop (top of valve) orifice sizesare available from 1/32" to 1/16" in Series 1.

Seals

SEAL MATERIALS01 Buna - N A general purpose, soft, synthetic rubbersuitable for most air, non-potable water and lightoil environments with temperatures to 200° F.

02 Fluorocarbon A soft, fluorocarbon rubber used primarily withhydrocarbon liquids such as gasoline,aerospace fuels, solvents, etc., which cancause swelling and distortion to Buna.Fluorocarbon is also used for oxygen service.The material is appropriate for highertemperature ranges, and is more resistant to“dry” heat.

03 Standard Neoprene A soft, synthetic rubber with excellent lowtemperature sealing and very good heat agingresistance.

06 Polyurethane Primarily used for high load applicationsinvolving non-corrosive gases & oils. Especiallygood for high pressure gases prone toabsorption such as CO2. Not recommended forwater, acids or chlorinated solvents.

• See page 9 for P/N System® Teflon and Neoprene are registered trademark of E.l. Dupont De Nemours Co® CHEMRAZ is a registered trademark of Green, Tweed & Co., Inc.

Up to 5/64" in Series 2 and 3 valves and up to 1/8" in Series 6valves. In addition, Norgren offers larger end stop orifices on allSeries 1, 2 & 3 to maximize flow. However, these orifices areapplication-sensitive. Please consult Norgren for assistance.

All orifices are “Precision Machined” to guarantee sealing surfacefinish and height for improved repeatability and reliability.

08 Teflon A synthetic material used in corrosive and semi-corrosive media.Teflon is virtually impervious to any fluid. Its ability to withstandhigh temperatures makes it especially suited for use with steam.However, it is not recommended for vacuum applications.

12 Neoprene W A soft, synthetic rubber that is used primarily for refrigerants,especially R-12 and R-22 with oil. The material has excellentdynamic sealing capabilities. Also characteristic of this material isimproved fluid resistance and lower swell.

13 Ethylene Propylene (EPR) Food Grade A soft, synthetic rubber ideal for beverages, potable water andsteam, (where steam pressure is below 50 PSI). Suitable for steamand hot water where temperatures are above Buna’s tolerances.EPR is not appropriate for petroleum liquids or petroleum-contaminated air. It is compatible with automotive brake fluids andphosphate ester synthetic oil.

16 Chemraz (Diaphragm Only) An inert perfluoroelastomer vulcanizate that stands up to a virtuallyunlimited range of corrosive and aggressive chemicals, includingorganic and inorganic acids, alkaline, ketones, esters, alcohols andfuels. Chemraz also demonstrates excellent resistance to heat,steam, flame, oil and ozone and retains pliability over atemperature range from -20°F to 450°F.

All standard Norgren valves are supplied withspring compensated Fluorocarbon upper seals,Buna-N lower seals and “O” Rings. Both upperand lower seals are also available in

Fluorocarbon, EPR, or Neoprene. In addition, lower seals areoffered in Teflon or polyurethane. Consult Norgren for temperaturelimits, durometer ratings, minimum order quantities orrequirements for special sealing materials.

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

V U 2 4 0 1 1 5 - 0 2 5 1 - 24VDC*

Page 14: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Spade• Available with

3/16" standardspade terminalsvertical style forSeries 2 and 3,and 1/4" standardspade terminalsvertical style forSeries 2, 3 and 6 andtop spade style forSeries 2 and 3

• Utilize the slottedhousing style forSeries 2, 3 and 6vertical spadeconstruction, as wellas yoke (open frame)for top spade

• Top spade, Series 2and 3 is available with internal arcsuppression diode or full wave rectification.

Vertical Spade Coil

Top Spade Coil

Coil Construction

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9914

Dry Coil• Tape wound coil ideal for general

purpose use in a clean dryenvironment

• Generally used with grommet andconduit style housings

• Norgren standard coil -suppliedwhen no suffixes are attached tovalve part number or as designatedon page 9

Free Standing Molded• Supplied when application requires

a more rugged, moisture resistantcoil

• Used with slotted housings, or yokein Series 2 & 3; grommet andconduit housing for Series 6

Potted Transfer Molded• Supplied when application requires a

more rugged, moisture resistant coil• Method of construction for Series 1,

2 and 3 conduit housing• Also method of construction for

Automotive Style coils and ANConnector-type for Series 6

Potted w/ Screw Terminals• Our most moisture resistant coil• Also available with internal arc

suppression diodes

Potted with Leads• Excellent for marine or automotive

applications• Available with your choice of

connector or terminal• Internally grounded, single wire

option also available

AN Connector• Supplied when application requires

a more rugged, moisture resistantcoil & connector

• High shock and vibration tested• Available with 2-Pin and 3-Pin

military style connectors• Consult factory for ordering

information

Coil Construction

B K

E

A DH

C

G

F

C D

A B

F

GE

K

A B C D E FSERIES 1.05 .94 .44 .85 .25 .64

2 & 3 (27) (24) (11) (22) (6) (16)SERIES 1.25 1.41 .54 1.25 .37 .88

6 (32) (36) (14) (32) (9) (22)

G H K97 .187 x .020

SERIES (25) .38 (5 x .5)2 & 3 1.03 (10) .250 x .032

(26) (6 x .8)SERIES 1.27 .52 .250 x .032

6 (32) (13) (6 x .8)

A B C D E F G KSERIES 1.06 1.18 1.00 .60 .61 1.19 .38 .250 x .032

2 & 3 (27) (30) (25) (15) (15) (30) (30) (6 x .8)

V U 2 4 0 1 1 5 - 0 2 5 1

Page 15: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Rectified Coils / Diodes

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 15

Rectified CoilsThere may be times when you have a standard AC circuit but can’thave the copper shading ring which is standard in this type of valvedue to media compatibility. Or, the application may be in a dirty ordusty environment where particulate causes the valve to buzz. Ineither case, a rectified coil will solve this problem. By adding twodiodes in the coil (for half-wave rectification), or four diodes (for full-wave rectification), the effective voltage to the coil is modified fromAC to DC. These rectified coils do not need any shading ring andperform as a DC coil with your standard AC input. The actual coilconstruction is designed for this type of rectification so you mustcontact the factory for ordering information. Since the addition ofthe diodes can make the physical size of the coil larger, it is notavailable in all types of coil and valve series. However, therectification can take place away from the coil, such as on thecustomer’s electronics, within their equipment. Consult Norgren foravailable options.

Arc SuppressionWhen DC voltage is disconnected from a solenoid valve, the coilreacts by generating its own voltage and sending a “spike” throughthe circuit. Depending on the size of the coil and the number ofamp turns it contains, this generated voltage can be very high. Inorder to suppress this “spike” and protect other sensitivecomponents in the electronic system, a diode is connected inparallel to the coils. Once the diode is placed in the coil it will nowhave a polarity. Since the diode only conducts in one direction thepolarity of the coil must be maintained so as not to burn out thediode and eliminate the protection it is meant to provide. Forordering data and coil availability, contact Norgren.

Rectified Coils and Coils with Arc Suppression Diodes

COIL DIODE

SWITCH

POWERSOURCE

+ –

+

COIL DIODE

SWITCH

POWERSOURCE

+ –

+

COIL

+

0

-

+

0

-

=

Page 16: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Porting

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9916

Manifold Mount Base ValvesNorgren’s standard manifold mount base valves offer a costeffective method of securing valves to manifolds, eliminatingcustom cavities or seat installations. Testing is simplified andmanifold design and “O” Ring sealing provides quick installation,interchangeability, service and replacement, without removing asingle supply line or fitting.

Norgren manifold mount style valves are available in all Series fromthe Norgren Jr. for low watt applications, to the Series 6 for highflow and high pressure requirements. Our complete line of manifoldmount type valves allows you to mix and match different stylevalves on one manifold assembly to accommodate your applicationrequirements.

See catalog valve charts for operating specifications pages 30-41.

Male Bottom PortThis option is available in Series 1, 2, & 3 with 1/8" NPT or 1/4"NPT male bottom port. The brass hex body has 1/8" NPT sideports for both the 1/8" and 1/4" models. Valves are available with amaximum orifice size of 1/8". When ordering a valve as a 2-waynormally closed version, please indicate whether the male port is tobe the inlet or outlet. The standard version has the side port as theinlet for both 2-way and 3-way valves.

This option is ideal as a 3-way operator for piloting a cylinder.Installation is fast and easy. Units also can be ordered with malethread Teflon tape to save you additional time. Available with anystandard Norgren electrical termination or housing style.

Bottom Port- “O” Ring SealNorgren offers an option on Series 1, 2, 3, and 6 for bottom portedvalves with an “O” Ring seal. This option utilizes one or two portson the bottom of the valve body to have a counterbore pocket for aface sealing “O” Ring. The manifold surface is simply machined flatwith matching hole locations and through holes matching up withthe mounting holes of the valves. When a valve is installed with themounting screws the “O” Ring provides a seal between the bottomof the valve body and the manifold surface. This feature is ideal foracrylic or other plastic manifolds where there is concern for threadlife or cracking of the block by over torquing.

Available in 2-way and 3-way valves. When only one bottom port isused, the remaining valve porting can be any of the optionsavailable in each series. Installation is quick and secure; troubleshooting or valve replacement can be accommodated withminimum effort.

Page 17: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Metering

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 17

MeteringProvides adjustable flow for dispensing a specific rate or volume offluid or gas. Permits controlled movement of a cylinder or actuator.Available in 2-Way and 3-Way valves. Norgren’s standard pressureratings and Cv’s apply.

Manifold Metering Manifold metering is available in side metering and bottom meteringversions. Please consult factory with design specifications foradditional data on metered manifolds and minimum orderquantities.Yoke housing not available with top plate.

Bottom Metering Available in Series 1 and Series 2 valves only. 1/8" NPTF ports onlyin stainless steel, brass and polypropylene. Maximum orifice size3/32" (1/8" in polypropylene).

Side Metering - Body and Adapter Available in Series 3 valves with 1/8" NPTF ports in stainless steelor brass. Series 3 with 1/4" NPTF ports available if mounting holesare not required. Series 6 valves with 1/8" or 1/4" NPTF ports instainless steel or brass. Maximum orifice size 1/8". Meteredadapters are available for 2-Way Normally Open or any 3-Wayvalves in Series 1, 2, or 3. Depending on the type of valve youselect, this metered adapter can control the flow of the inlet, outletor exhaust. When coupled with either side or bottom body metering,it allows you to control your media in two directions independently.

Full Flow Shut Off

Full Flow Shut Off

Page 18: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Fittings and Filters

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9918

Series 6 Valves with 3/8" Ports and 3/8" OrificeFor specific applications when our standard 1/4" orifice just can’tdeliver enough flow, Norgren can provide our Series 6 valve with a3/8" orifice. Typically used for gravity feed systems, this valvecomes in 2-way normally closed models only. It has a maximumoperating pressure differential of 5 PSI and a Cv factor of .90. Thishigh flow valve is supplied with 3/8" NPT ports on a standard brassor stainless steel body, or with even larger ports on a single stationmanifold base. Order by the following part numbers for grommetstyle valves with body material of: Brass- 681119 or StainlessSteel- 681019. Be sure to specify the applicable voltage or otherdesired options when ordering.

Valves with Brazed in Fittings or Tube EndsNorgren will provide any of our brass body valves with eitherbrazed in fittings or tube ends for OEM applications. Ideal fornatural gas, propane or refrigeration systems where leaking fittingsor tube connections cannot be tolerated. Select from standardfittings and tube sizes or call Norgren to discuss a customconfigured design. This feature applies to our complete line of 2-and 3-way valves and also our standard and custom manifoldassemblies.

Filters and ScreensWhile solenoid valves are highly reliable and fairly simple devices,they cannot tolerate very much contamination. If your system doesnot already include adequate filtration, Norgren can provide avariety of screens or filters to minimize contaminants and costlydown time. From a simple 50 mesh metal screen installed in thevalve port to more precise types of cartridge filters, Norgren willprovide and install the filtration necessary to keep your systemrunning.

Page 19: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Norgren Jr. Series

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 19

Norgren Jr. Series - .65 Watt

The Norgren Jr. series provides a small solution for your valverequirements but doesn’t compromise on performance. Available inall 2- and 3-way configurations the same as our standard series,the Norgren Jr. valve is only .800" in diameter, 1.73" high andweighs less than three ounces.

Unlike other low watt valves, the Norgren Jr. series is equallycompatible with air, water, gases, vacuum and many other fluids.Our patented construction* optimizes the performance of eachvalve. Norgren Jr. valves are designed for long life. Hundreds ofmillions of cycles are typical, however this may fluctuate dependingon the specific application.

Standard construction of brass or stainless steel bodies, theNorgren Jr. series has 12" long, #24 AWG electrical leads. Theleads exit the top of the valve for ease of orientation. Buna sealsand “O” Rings are standard. Other wetted parts are Ryton® andstainless steel. The nickel plated housing provides for a durable,corrosion resistant package. Coils are available in 5, 12, 15 and 24 volt DC.

In addition to the standard 10-32 ported valves, the Norgren Jr.series is available with manifold mount bodies or as an operator.For critical applications involving corrosive or ultra pure media,Norgren Jr. isolation valves are the answer. Refer to pages 21-25for ordering information and specifications.

* U.S. Patent #5,207,245 and # 5,289,841

Page 20: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Electronic / Pneumatic Interface System

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9920

When numerous valves are required to control air, gas or vacuum within your system, Norgren Jr. electronic/ pneumaticinterface cards are the ideal solution. Select the 2- or 3-way manifold mount Norgren Jr. valve and the number ofstations you require (8, 12, and 16 are standard). Norgren will provide the entire circuit card with manifold valvesassembled and ready to install into your equipment. Valves are actuated with a standard 25 pin cable connector. Seepage 46 for specifications and dimensions.

• Single or double sided manifolds• Wide variety of base materials• Coil suppression diodes- standard• LED indicator- standard• Optional electrical manual override

Electronic/Pneumatic Interface System

Page 21: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Norgren Jr. Ordering

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 21

The following matrix system provides theselection criteria for creating a Norgren Jr. partnumber. Performance characteristics includingorifice sizes, flow coefficients (Cv) and pressure

Norgren Jr. Ordering Information

How to Order Your Norgren Jr. ValveNorgren ordering code is contained within our part number:

Standard Norgren Jr.

* Isolated Version Only† Halar is a fluoroplastic co polymer with exceptional strength and wear properties and is resistant to creep.

For ordering information of Norgren Jr isolation valves, refer to pages 22 - 25.For manifold information, refer to pages 26 - 29.

** Poppet style valves only

PREFIXES(Optional)G = Isolated 2WNC only *Y = Oxygen Service

SERIES9 = Norgren Jr.

PORT6 = Manifold Mount7 = #10-32 UNF

HOUSING1 = Grommet(Leads exit top)

BODY0 = Stainless Steel1 = Brass3 = Operator8*† = Halar®

9* = Acrylic

FUNCTION1 = 2WNC2 = 2WNO4 = 3WNC5 = 3WNO6 = 3WMP7 = 3WDC

ORIFICE2 = 1/16

SPECIFY VOLTAGE5 VDC

12 VDC15 VDC24 VDCCoils are standardClass B construction

SEAL01 = Buna02 = Fluorocarbon®

13 = EPR*

V G 9 7 1 0 1 2 - 1 3 - 5VDC

Orifice Cv Manifold ManifoldType Body/Stop Body/Stop MOPD SS Brass Operator Mount SS Mount BR

2WNC 1/16" - .050 - 100 V971012 V971112 V971312 V961012 V9611122WNO - 3/64" - .025 90 V971022 V971122 V971322 V961022 V9611223WNC 1/16" 3/64" .035 .020 80 V971042 V971142 V971342 V961042 V9611423WNO 1/16" 3/64" .050 .015 60 V971052 V971152 V971352 V961052 V9611523WMP 1/16" 3/64" .035 .015 40 V971052 V971162 V971362 V961062 V9611623WDC 1/16" 3/64" .050 .025 60 V971052 V971172 V971372 V961072 V961172

ratings are included in the standard part number chart foundbelow. Of course, Norgren will manufacture custom designs for theOEM.

Page 22: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

22 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

Norgren Isolation Valves

● Ideal for control of corrosive and aggressivemedia

● Elastomer diaphragm provides protection fromaggressive, corrosive, and gritty media

● Isolation valves can be equipped with a lowwattage coil (as low as 0.65 watts in the NorgrenJr. series)

● Valves can also be integrated into standardmanifolds or intricate custom manifoldassemblies

● Isolation valves are available in a 2-way normallyclosed configuration

● Two valves can be combined on a common basefor 3-way operation

Flow Body OrificeRates (Cv) Materials Size Porting

SERIES 1 .250Delrin®, PVC,

1/32"-5/32" 1/8" NPTKynar®

SERIES 2 .250Delrin®, PVC,

1/32"-5/32" 1/8" NPTKynar®

SERIES 6 .545Delrin®, PVC,

1/32"-1/4" 1/8" NPTKynar®

NORGREN JR. .06Acrylic,

1/16" 10-32UNFHalar®

Series Series Series Norgren Seals 1 2 6 Jr.

CHEMRAZ® Yes Yes No NoEPR Yes Yes No Yes

FLUOROCARBON® Yes Yes Yes No

De-Energized Energized

Page 23: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Isolation Valves

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 23

Selection Criteria for Isolation Style ValvesNorgren Jr.

FEATURE Series 1 Series 2 Series 6 Series 9Size 1 1 1-5/8 0.80Maximum MOPD (psi) 95 120 130 30Vacuum Service Yes Yes Yes YesMax. Cv - Body 0.250 0.250 0.545 0.06Power Rating 6 watts 7 watts 10 watts .65 wattsLead Wire Gauge 20 AWG/18 AWG 20 AWG/18 AWG 18 AWG 24 AWGOptional Low Wattage Coils Available Available N/A Standard1/8" NPTF Ports Standard Standard Standard N/A#10 - 32 UNF Ports Available Available Available Standard1/4 - 28 UNF Available Available Available N/AGrommet Housing Available Available Available StandardConduit Housing Available Available Available N/ASpade Coil Available Available Available N/AManifolds - See Pages 26-27 Available Available Available Available

PREFIXESG = Isolated SERIES

1 = Series 12 = Series 26 = Series 6

PORT6 = Manifold Mount7 = #10-32 UNF

HOUSING1 = Grommet2 = Conduit3 = Yoke7 = Grommet w/bracket8 = Conduit w/bracket9 = Slotted0 = Slotted w/bracket

BODY MATERIAL3 = Operator4 = Delrin®

5 = PVC6 = Kynar®

FUNCTION1 = 2WNC

ORIFICE0 = 1/32"1 = 3/64"2 = 1/16"3 = 5/64"4 = 3/32"5 = 1/8"6 = 5/32"7 = 3/16" (Series 6* only)8 = 1/4" (Series 6* only)

VOLTAGESee page 8

SEAL02 = Fluorocarbon®

13 = EPR* (Series 1, 2)16 = Chemraz® (Series 1, 2)

COIL OPTIONSSee page 8

V G 2 7 9 6 1 2 - 0 2 6 1 - 12VDCSeries 1, 2 & 6

PREFIXESG = Isolated SERIES

9 = Series 9 Norgren Jr.

PORT7 = #10-32 UNF8 = 1/4 - 28 UNF HOUSING

1 = Grommet (leads exit top)

BODY MATERIAL1 = Brass8 = Halar®

9 = Acrylic

FUNCTION1 = 2WNC

ORIFICE2 = 1/16"

VOLTAGE5VDC

12VDC15VDC24VDC

SEAL13 = EPR

V G 9 7 1 9 1 2 - 1 3 - 12VDCSeries 9 Norgren Jr.

Page 24: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

24 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

Norgren Isolation Valves

● Isolation valves can be combined on a manifoldblock to simplify your pneumatic or liquid circuit

● Complete line of standard manifold designs andmaterials

● Norgren offers custom designed manifoldscomplete with fittings, tubing and otheraccessories

For more information on manifolds, please refer to pages 26 through 29.

Isolation Valve Manifolds

Orifice Standard Valve BodyDiameter Cv Factor MOPD Kynar ® Delrin ® PVC

Series 1 1/32" 0.025 95 VG141610 VG141410 VG1415103/64" 0.045 75 VG141611 VG141411 VG1415111/16" 0.075 55 VG141612 VG141412 VG1415125/64" 0.115 35 VG141613 VG141413 VG1415133/32" 0.155 25 VG141614 VG141414 VG1415141/18" 0.210 15 VG141615 VG141415 VG1415155/32" 0.250 10 VG141616 VG141416 VG141516

Series 2 1/32" 0.025 120 VG241610 VG241410 VG2415103/64" 0.045 100 VG241611 VG241411 VG2415111/16" 0.075 75 VG241612 VG241412 VG2415125/64" 0.115 55 VG241613 VG241413 VG2415133/32" 0.155 45 VG241614 VG241414 VG2415141/18" 0.210 30 VG241615 VG241415 VG2415155/32" 0.250 20 VG241616 VG241416 VG241516

Series 6 1/32" 0.031 130 VG641610 VG641410 VG6415103/64" 0.058 110 VG641611 VG641411 VG6415111/16" 0.078 95 VG641612 VG641412 VG6415125/64" 0.117 70 VG641613 VG641413 VG6415133/32" 0.167 60 VG641614 VG641414 VG6415141/18" 0.241 50 VG641615 VG641415 VG6415155/32" 0.316 40 VG641616 VG641416 VG6415163/16" 0.398 30 VG641617 VG641417 VG6415171/4" 0.545 20 VG641618 VG641418 VG141518

Norgren Jr. OrificeSeries Diameter Cv Factor MOPD Kynar ® Delrin ® PVC

Series 9 1/32" 0.025 95 VG141610 VG141410 VG141510

Page 25: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Back Pressure

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 25

Diaphragm Isolation Valves have a largedifference in pressure area between open andclosed, creating a sensitivity to back pressure.Excessive back pressure can hinder the closingof the valve. Please use the back pressurecharts below to determine the maximumoperating pressure of the valve based on the

Isolation Valve Back Pressure De-rating Curves

1

100

2

5/32

1/8

3/32

5/64

1/16

3/64

1/32

3 4 5 6 7

90

80

70

60

50

40

30

20

10

0

Back Pressure - PSI

Pre

ssu

re R

atin

g -

PS

I

1

110

2

5/32

1/8

3/32

5/64

1/16

3/64

1/32

3 4 5 6 7

100

90

80

70

60

50

40

30

20

10

0

Back Pressure - PSI

Pre

ssu

re R

atin

g -

PS

I

1

110

2

5/323/161/4

1/83/32

5/64

1/163/64

1/32

3 4 5 6 7

120

130

100

9080

70

6050403020

10

0

Back Pressure - PSI

Pre

ssu

re R

atin

g -

PS

I

1 2 3 4 5 6 7 8 9 10 11 12

192021222324252627282930

18171615

Back Pressure - PSI

Pre

ssu

re R

atin

g -

PS

I

Series 1 Isolation Valves Series 2 Isolation Valves

Series 6 Isolation ValvesNorgren Jr. Series

Isolation Valves

maximum potential back pressure in the application. Choose theorifice size which meets a worst case condition.Unless a preference for diaphragm body shape is specificallyrequested, valves may be shipped with either square or roundbodies, at Norgren’s discretion, and depending on availability orsize of order.

Page 26: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Manifolds

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9926

Operator Mounting Type Manifolds• Series 1 and Series 2 operators are available for gang mounting

on aluminum, brass or plastic sub-plates.• Manifolds can be selected with 1/8" NPTF or 1/4" NPTF ports.• Orifice sizes up to 3/16" with precision machined-in seats are

standard.• Both 2-Way and 3-Way operators may be combined on the same

manifold.• Manifolds with up to 16 stations are available as standard.• An upper manifold plate can be ordered for common porting on

2-Way Normally Open and all 3-Way valves.

Isolation Style Manifold• Provides a dry isolated valve operator for the control of corrosive

and aggressive media.• The diaphragm seal (Fluorocarbon®, Chemraz® or EPR), isolates

all metal parts from the media.• The manifold material is available in PVC, Delrin®, Kynar®, and

acrylic.• Operators are available as a 2-way normally closed valve only

However, two valves can be combined for 3-way operation.• Orifice sizes are available from 1/32" to 5/32" with Cv factors up

to 0.545. Please refer to page 22 - 25 for specifications.

Manifold Mount Valve Type Manifolds• Series 1, 2, 6 and Norgren Jr. valves are available for gang

mounting on aluminum, brass or plastic sub-plates.• Manifolds can be selected with 10-32 UNF, 1/8" NPTF or 1/4"

NPTF ports.• Orifice sizes up to 1/8" in Series 1, 2, and orifice sizes up to 1/4"

in Series 6 models are available, and 1/16" in Norgren Jr.• Pressure ratings are the same as those listed for the individual

valves in this catalog except that the maximum operatingpressure is limited to 400 PSI for UL recognition.

• 2-Way and 3-Way valves may be combined on the same manifoldUp to 16 stations are available on Series 1 and 2 valves, and upto 6 stations are standard on Series 6 valves.

• An upper manifold plate can be ordered for common porting on2-Way Normally Open and all 3-Way valves. This option is notavailable for Norgren Jr.

Solenoid valve manifolds simplify the purchasing, installation,testing, and repair/replacement of solenoid valve components whileenhancing system integrity. Integrating a group of solenoid valves,pressure switches, check valves, regulators or gauges into oneassembly makes a complete package, eliminating tubing, fittingsand potential leak points. Additionally, wire harness requirementsare simplified.

ManifoldsSimplify solenoid valve installation with Norgren manifold assemblies. Norgren manifoldsprovide an economical and effective means of gang mounting solenoid valves

Modular valves and other components can bereplaced or maintained without disturbingplumbing thus reducing maintenance costs anddowntime.

® CHEMRAZ is a registered trademark of Green, Tweed & Co., Inc.

Page 27: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Manifolds

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 27

Acrylic SubplatesA great answer for simplified design and easy installation ofcomplex media flow requirements. Use of an acrylic base permitsthe flow of various media through a single base using multipleinlets and outlets. Flow paths can also be varied and directed tomeet design requirements. Norgren application engineers can helpyou select the most effective design for easy installation, access,and the best product aesthetics. Acrylic subplates are supplied forOEM applications only.

Additional OEM ManifoldDesign Capabilities

Norgren manifolds offer many additional options such as:

• Metering of valves for flow control.• Sub-plates of many materials including brass, Delrin,

430 SS, aluminum, acrylic and Kynar .• Unique configurations to accommodate pressure regulators,

pressure gauges, transducers, and/or switches as well as flowpaths to meet your specific requirements.

• Other port sizes and locations.• Internal check valves.• Teflon taped fittings.• Test ports.• Multi-media manifolds.• Flow or no-flow monitoring.

Consult Norgren for application engineering assistance.

Norgren Jr. ManifoldsAll of the manifold types described on these pages are alsoavailable in the Norgren Jr. Series.

FEATURES:• Operator Style manifolds for small profile, low cost OEM

applications.• Manifold mount style for ease of installation and service.• Inert plastic bases with isolation solenoid operators and ethylene

propylene diaphragms for aggressive or high purity media.• Electronic/Pneumatic interface circuit cards for gang mounting

multiple valves for a computer driven system.

Manifolds

Page 28: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

28 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

Manifold Assemblies withCartridge Fittings Installed

● No fittings to install, Teflon ® tape or lubricant,and no leaks

● Compatible with both air and liquids

● Available in Series 1, 2 or 6 manifold mount stylevalves with base materials of Delrin ®, PVC, brassor aluminum

● As always, Norgren is ready to manufacture a“special” to meet your exact OEM specifications

Tubing Outside DiameterSeries 1 1/4" 3/8"Series 2 1/4" 3/8"Series 6 1/4" 3/8" 1/2"

Please note: All manifolds with the cartridge fittings installed havea maximum pressure rating of 150 PSI, even though the actualvalve you select may have a higher pressure rating.

Overall manifold dimensions for this option can be found on page 48.

Minimize your labor and material cost by ordering this uniquepackage from Norgren. With cartridge fittings installed into themanifold base, you simply push in the proper size tube and you aredone.

Select the valve or manifold assembly desired. See the partidentification numbering system, the standard manifold orderinginformation or the Valve Inquiry Application Sheet found on page83. Specify on your request to have cartridge fittings installed. Besure to indicate the outside diameter (O.D.) of the tubing you willbe using. The following standard sizes are available by Series:

Page 29: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Manifolds

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 29

It’s easy to order your own standard NorgrenManifold assembly using the simple selectionchart below. First, select the manifold mountvalve or valve operator from the part numberingcharts on pages 30 through 41 or create the

Number of StationsFill in the number of valve stations you needafter the “M”. This can be up to 16 stations forseries 1, 2 or Norgren Jr. Manifold mountvalves and 6 stations for series 6 manifoldmount valves. For operator style manifoldswhere the cavity is machined into the base, 16stations is the maximum for series 1, 2 andNorgren Jr. series and 6 stations for series 6.

PortingSelect the porting configuration and port size tofit your application. Choose from the offeringsbelow and enter the appropriate letter after thenumber of stations.

Base Material Next, select the base material which offers thebest media compatibility for your application.Place the appropriate letter in the last positionof the part number sequence.

Standard Manifold Ordering Information

STD. MANIFOLD MOUNT OROPERATOR VALVE NUMBER

OPTIONAL NUMBER OFSTATIONS

PORTING VOLTAGE

MATERIAL

V 2 4 0 3 1 5 - 0 2 5 1 M 0 6 A B - B

Porting Valve Valve Common Common Outlet OutletDesignation Series Type Port Size Marking Port Size Marking Comments

A S1, S2, S6 2WNC 1/8"NPT IN 1/8"NPT OUTB S1, S2, S6 2WNC 1/4"NPT IN 1/4"NPT OUTC S1, S2, S6 3WNO 1/8"NPT EXH 1/8"NPT CYL Inlet Port is through Valve AdapterD S1, S2, S6 3WNO 1/4"NPT EXH 1/4"NPT CYL Inlet Port is through Valve AdapterC S1, S2, S6 3WNC 1/8"NPT IN 1/8"NPT CYL Exhaust Port is through Valve AdapterD S1, S2, S6 3WNC 1/4"NPT IN 1/4"NPT CYL Exhaust Port is through Valve AdapterC S1, S2, S6 3WMP 1/8"NPT NC 1/8"NPT COM N.O. Port is through Valve AdapterD S1, S2, S6 3WMP 1/4"NPT NC 1/4"NPT COM N.O. Port is through Valve AdapterJ Norgren Jr. 2WNC 1/8"NPT IN 10-21 UNF OUTR Norgren Jr. 3WNO 1/8"NPT EXH 10-21 UNF CYL Inlet Port is through Valve AdapterR Norgren Jr. 3WNC 1/8"NPT IN 10-21 UNF CYL Exhaust Port is through Valve AdapterR Norgren Jr. 3WMP 1/8"NPT NC 10-21 UNF COM N.O. Port is through Valve Adapter

Note: For 3-way directional control manifolds, use the 3-way multi-purpose manifold which most closely fits your need.For the 2-way normally open manifolds, consult Norgren.

part number from the part number identification system on page 9.Provide the numbers for the desired seal and coil constructionoptions if applicable. This will give you the valve portion of themanifold. Now, select the base to complete your assembly.

A) Aluminum - Best suited for non-critical air, vacuum or inertgases.B) Brass - Commonly used for non-potable water applications orother low pressure fluids or oils.D) Delrin® - FDA grade material is used for potable waterapplications, critical gas sampling or high purity systems.

VoltageAfter selecting your standard manifold part number, remember toinclude the operating voltage. Select the appropriate letter fromthe following standard voltages and add it at the end of yourmanifold part number:

Norgren Jr. All OtherVoltage Designation Series Series5VDC A Standard Special

12VDC B Standard Standard15VDC C Standard Special24VDC D Standard Standard24/60 E N/A Standard

110/50 F N/A Standard120/60 G N/A Standard220/50 H N/A Standard240/60 I N/A Standard

Page 30: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9930

To help you find the right valve for your application, the types ofvalves are arranged in two-page spreads (2-Way Normally Open,2-Way Normally Closed, 3-Way Normally Closed Line Connect, 3-Way Multi-Purpose, 3-Way Normally Open, 3-Way DirectionalControl). For each valve type, the first boxes are arranged byNorgren Series designation (Series 1, 2, 3 and 6). The second,smaller subset of rows designate the various orifice diameters forthe Series. Series 1 valves offer the smallest package size andtypically have lower flows and pressures for the same orifice sizeas those of our largest, Series 6, valves. As you move from left toright across the columns on the spread, you will find the Cv factor(flow coefficient) and Maximum Operating Pressure Differential

Finding the Right Valve

2-Way Normally Open

Orifice Cv Standard Valve BodyDiameter Factor MOPD Grommet

Body Stop Body Stop (psi) Stainless Steel BrassSeries 1 1/32 0.035 300 V141020 V141120

3/64 0.050 200 V141021 V1411211/16* 0.095 150 V141022 V141122

Series 2 1/32 0.035 400 V241020 V2411203/64 0.050 300 V241021 V2411211/16 0.095 180 V241022 V2411225/64* 0.135 140 V241023 V241123

Orifice Cv Standard Valve Body (Grommet)Diameter Factor MOPD Stainless Steel Brass

Body Stop Body Stop (psi) 1/8" NPTF 1/4"NPTF 1/8" NPTF 1/4"NPTFSeries 3 1/32 0.035 400 V341020 V351020 V341120 V351120

3/64 0.050 500 V341021 V351021 V341121 V3511211/16 0.095 180 V341022 V351022 V341122 V3511225/64* 0.140 140 V341023 V351023 V341123 V351123

Series 6 1/32 0.035 1000 V641020 V651020 V641120 V6511203/64 0.050 600 V641021 V651021 V641121 V6511211/16 0.095 350 V641022 V651022 V641122 V6511225/64 0.140 250 V641023 V651023 V641123 V6511233/32 0.200 175 V641024 V651024 V641124 V6511241/8 0.295 100 V641025 V651025 V641125 V651125

OUT

IN IN

* Larger stop orifice available with reduced pressure ratings; consult Norgren.

(MOPD) for the corresponding orifice diameter.Part numbers for Norgren’s valve body,operator (valve without body), manifold mountand 1/8" NPT male bottom port follow. All partnumbers are shown with grommet housingdesignated by numeral 1 in the third position.Part numbers can be modified by selecting yourchoice of housing, seal material or molded coiland placing the appropriate numbers into thedesignated position in the part numbersequence (see page 9).

Page 31: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 31

Moving further to the right, you will find partnumbers for Plastic Valve Body and Low WattValve specifications (where available). To ordera plastic valve, simply substitute the valve bodynumber for the corresponding stainless steel orbrass valve body number.

Low Watt Valves have Cv factors and pressureratings lower than standard valves. To order aLow Watt Valve, simply prefix the applicable partnumber with the letter at the top of the Low Wattspecification column for the wattage andpressure rating selected.

2-Way Normally Open (2WNO) - Valve with twoports, inlet and outlet. Valve is open in a de-energized state, and closes when energized.Valve has one orifice which is located in theend stop.

MANIFOLD MOUNT 1/8" PLASTIC Valve BodyOPERATOR NPT

Stainless Steel Brass Male 1/8" NPTF 7/16 - 20 UNFSeries 1 V141320 V161020 V161120 V131120

V141321 V161021 V161121 V131121V141322 V161022 V161122 V131122

Series 2 V241320 V261020 V261120 V231120V241321 V261021 V261121 V231121V241322 V261022 V261122 V231122V241323 V261023 V261123 V231123

OPERATOR MANIFOLD MOUNT 1/8" PLASTIC Valve BodyNPT

1/8" NPTF 1/4" NPTF Stainless Steel Brass Male 1/8" NPTF 7/16 - 20 UNFSeries 3 V341320 V351320

V341321 V351321V341322 V351322V341323 V351323

Series 6 V641320 V651320 V661020 V661120V641321 V651321 V661021 V661121V641322 V651322 V661022 V661122V641323 V651323 V661023 V661123V641324 V651324 V661024 V661124V641325 V651325 V661025 V661125

For Example: B241114 is a two-way normally closed valve with abrass body, grommet housing and orifice size or 3/32". The correctMOPD for this valve would be 20 PSI at 2.0 watts.

Gray areas indicate that the options described in the columnheader are not available.

Page 32: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

ORIFICE Cv STANDARD Valve Body - GrommetDIAMETER Factor MOPD Stainless Steel Brass

Body Stop Body Stop (psi) 1/8" NPTF 1/4" NPTF 1/8" NPTF 1/4" NPTF OPERATORSeries 3 1/32 0.035 1000 V341010 V351010 V341110 V351110 V341310

3/64 0.050 600 V341011 V351011 V341111 V351111 V3413111/16 0.095 400 V341012 V351012 V341112 V351112 V3413125/64 0.140 300 V341013 V351013 V341113 V351113 V3413133/32 0.185 250 V341014 V351014 V341114 V351114 V3413141/8 0.265 150 V341015 V351015 V341115 V351115 V341315

5/32 0.330 100 V341016 V351016 V341116 V351116 V3413163/16 0.385 40 V341017 V351017 V341117 V351117 V3413171/4 0.450 15 V341018 V351018 V341118 V351118 V341318

Series 6 1/32 0.035 1200 V641010 V651010 V641100 V651110 V6413103/64 0.050 1000 V641011 V651011 V641101 V651111 V6413111/16 0.095 500 V641012 V651012 V641102 V651112 V6413125/64 0.140 300 V641013 V651013 V641103 V651113 V6413133/32 0.200 200 V641014 V651014 V641104 V651114 V6413141/8 0.295 150 V641015 V651015 V641105 V651115 V641315

5/32 0.370 110 V641016 V651016 V641106 V651116 V6413163/16 0.435 60 V641017 V651017 V641107 V651117 V6413171/4 0.610 30 V641018 V651018 V641108 V651118 V6413183/8 0.900 5 V681019† V681119†

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9932

2-Way Normally Closed

OUTINOUTIN

ORIFICE Cv STANDARD Valve Body MANIFOLD MOUNT*DIAMETER Factor MOPD Grommet OPERATOR Valve Body-Grommet

Body Stop Body Stop (psi) SS Brass SS BrassSeries 1 1/32 0.035 800 V141010 V141110 V141310 V161010 V161110

3/64 0.050 500 V141011 V141111 V141311 V161011 V1611111/16 0.095 300 V141012 V141112 V141312 V161012 V1611125/64 0.135 200 V141013 V141113 V141313 V161013 V1611133/32 0.175 175 V141014 V141114 V141314 V161014 V1611141/8 0.245 100 V141015 V141115 V141315 V161015 V161115

5/32 0.290 50 V141016 V141116 V141316 V161016 V161116Series 2 1/32 0.035 1000 V241010 V241110 V241310 V261010 V261110

3/64 0.050 600 V241011 V241111 V241311 V261011 V2611111/16 0.095 400 V241012 V241112 V241312 V261012 V2611125/64 0.135 300 V241013 V241113 V241313 V261013 V2611133/32 0.175 250 V241014 V241114 V241314 V261014 V2611141/8 0.245 150 V241015 V241115 V241315 V261015 V261115

5/32 0.290 100 V241016 V241116 V241316 N/A N/A

* Manifold Mount valve has maximum 400 MOPD rating for UL recognition.** Plastic body valves have a maximum pressure rating of 200 PSI.† These valves are supplied with 3/8" NPTF ports.

Page 33: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 33

** Plastic body valves have a maximum pressure rating of 200 PSI.† These valves are supplied with 3/8" NPTF ports.

Two-Way Normally Closed (2WNC) - Valve withtwo ports, inlet and outlet. Valve is closed in ade-energized state, and opens when energized.Valve has one orifice which is located in thebody.

1/8 PLASTIC BODY PLASTIC VALVE** LOW WATT SpecificationsNPT CV Factor 1/8" NPTF 7/16 - 20 Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

MALE Body Stop FEMALE UNF Body Stop A B C DSeries 1 V131110 0.030 125 300 500 775

V131111 0.050 30 100 175 300V131112 0.085 - 30 65 95V131113 0.125 - 15 40 65V131114 0.170 - 10 25 40V131115 0.225 - - - 4

N/A 0.280 - - - -Series 2 V231110 N/A N/A N/A 0.030 300 540 780 1000

V231111 0.062 V241711 V221711 0.050 50 125 240 340V231112 0.090 V241712 V221712 0.085 15 60 100 160V231113 N/A N/A N/A 0.125 5 30 55 95V231114 0.205 V241714 V221714 0.170 3 20 40 55V231115 0.245 V241715 V221715 0.225 - 12 25 35

N/A 0.310 V241716 V221716 0.280 - 7 14 20

MANIFOLD MOUNT Valve Body LOW WATT SpecificationsGROMMET Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

Stainless Steel Brass Body Stop A B C DSeries 3 0.030 300 540 780 1000

0.050 50 125 240 3400.085 15 60 100 1600.125 5 30 55 950.180 3 20 40 550.225 - 12 25 350.280 - 7 14 20

- - - - -

Series 6 V661010 V661110V661011 V661111V661012 V661112V661013 V661113V661014 V661114V661015 V661115V661016 V661116V661017 V661117V661018 V661118

Page 34: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9934

3-Way Normally ClosedLine ConnectFor Free Vent, change fifth digit from 4 to 3

EXH

IN CYL

EXH

IN CYL

ORIFICE Cv STANDARD Valve Body MANIFOLD MOUNTDIAMETER Factor MOPD Grommet OPERATOR Valve Body-Grommet

Body Stop Body Stop (psi) SS Brass SS BrassSeries 1 1/32 1/32 0.035 0.025 200 V141040 V141140 V141340 V161040 V161140

3/64 3/64 0.050 0.065 150 V141041 V141141 V141341 V161041 V1611411/16 1/16* 0.085 0.115 100 V141042 V141142 V141342 V161042 V1611425/64 1/16* 0.125 0.115 80 V141043 V141143 V141343 V161043 V1611433/32 1/16* 0.165 0.115 60 V141044 V141144 V141344 V161044 V1611441/8 1/16* 0.240 0.115 40 V141045 V141145 V141345 V161045 V161145

5/32 1/16* 0.285 0.115 10 V141046 V141146 V141346 V161046 V161146Series 2 1/32 1/32 0.035 0.025 250 V241040 V241140 V241340 V261040 V261140

3/64 3/64 0.050 0.065 175 V241041 V241141 V241341 V261041 V2611411/16 1/16 0.085 0.115 125 V241042 V241142 V241342 V261042 V2611425/64 5/64* 0.125 0.140 100 V241043 V241143 V241343 V261043 V2611433/32 5/64* 0.165 0.140 75 V241044 V241144 V241344 V261044 V2611441/8 5/64* 0.240 0.140 45 V241045 V241145 V241345 V261045 V261145

5/32 5/64* 0.285 0.140 20 V241016 V241146 V241346 N/A N/A

ORIFICE Cv STANDARD Valve Body - GrommetDIAMETER Factor MOPD Stainless Steel Brass

Body Stop Body Stop (psi) 1/8" NPTF 1/4" NPTF 1/8" NPTF 1/4" NPTFSeries 3 1/32 1/32 0.035 0.025 250 V341040 V351040 V341140 V351140

3/64 3/64 0.050 0.065 175 V341041 V351041 V341141 V3511411/16 1/16 0.085 0.115 125 V341042 V351042 V341142 V3511425/64 5/64* 0.125 0.145 100 V341043 V351043 V341143 V3511433/32 5/64* 0.165 0.145 75 V341044 V351044 V341144 V3511441/8 5/64* 0.240 0.145 45 V341045 V351045 V341145 V351145

5/32 5/64* 0.290 0.145 20 V341046 V351046 V341146 V3511463/16 5/64* 0.345 0.145 10 V341047 V351047 V341147 V3511471/4 5/64* 0.415 0.145 5 V341048 V351048 V341148 V351148

Series 6 1/32 1/32 0.035 0.025 300 V641040 V651040 V641140 V6511403/64 3/64 0.050 0.065 250 V641041 V651041 V641141 V6511411/16 1/16 0.090 0.115 200 V641042 V651042 V641142 V6511425/64 5/64 0.135 0.180 175 V641043 V651043 V641143 V6511433/32 3/32 0.180 0.210 125 V641044 V651044 V641144 V6511441/8 1/8 0.275 0.240 85 V641045 V651045 V641145 V651145

5/32 1/8 0.370 0.240 50 V641046 V651046 V641146 V6511463/16 1/8 0.455 0.240 30 V641047 V651047 V641147 V6511471/4 1/8 0.650 0.240 15 V641048 V651048 V641148 V651148

* Larger stop orifice available with reduced pressure ratings; consult Norgren.

Page 35: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 35

Three-Way Normally Closed (3WNCFV or3WNCLC) Valve with three ports, and twoorifices. One orifice is located in the body andthe other in the end stop. The three ports arethe “IN”, “EXHAUST” and “CYLINDER”. When

1/8 PLASTIC BODY PLASTIC VALVE** LOW WATT SpecificationsNPT CV Factor 1/8" NPTF 7/16 - 20 Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

MALE Body Stop FEMALE UNF Body Stop A B C DSeries 1 V131140 0.030 0.025 100 - 150 -

V131141 0.050 0.060 - 80 120 -V131142 0.085 0.105 - 45 650 -V131143 0.120 0.105 - 25 - 50V131144 0.150 0.105 - - 20 35V131145 0.225 0.105 - - 10 20

N/A 0.270 0.105 - 7 - 10Series 2 V231140 N/A N/A N/A N/A 0.030 0.025 150 185 210 -

V231141 0.062 .065 V241741 V221741 0.050 0.060 80 120 140 170V231142 0.090 .115 V241742 V221742 0.085 0.105 45 60 - 95V231143 N/A N/A N/A N/A 0.120 0.125 25 - 50 65V231144 0.205 .140 V241744 V221744 0.150 0.125 20 - 35 55V231145 0.245 .140 V241745 V221745 0.225 0.125 - 10 20 30

N/A 0.310 .140 V241746 V221746 0.270 0.125 - 7 10 20

MANIFOLD MOUNT Valve Body LOW WATT SpecificationsOPERATOR Grommet Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

1/8" NPTF 1/4" NPTF Stainless Steel Brass Body Stop A B C DSeries 3 V341340 V351340 0.030 0.025 150 185 210 -

V341341 V351341 0.050 0.060 80 120 140 170V341342 V351342 0.085 0.105 45 60 - 95V341343 V351343 0.120 0.125 25 - 50 65V341344 V351344 0.150 0.125 20 - 35 55V341345 V351345 0.225 0.125 - 10 12 30V341346 V351346 0.270 0.125 - 7 10 20V341347 V351347 - - - - -V341348 V351348

Series 6 V641340 V651340 V661040 V661140V641341 V651341 V661041 V661141V641342 V651342 V661042 V661142V641343 V651343 V661043 V661143V641344 V651344 V661044 V661144V641345 V651345 V661045 V661145V641346 V651346 V661046 V661146V641347 V651347 V661047 V661147V641348 V651348 V661048 V661148

** Plastic Body valves have a maximum pressure rating of 200 PSI.

Note: Series 6 manifold mount 3-Way valves have a 1/4" NPTF adapter as standard. 1/8" NPTF available upon request.

the valve is de-energized, the inlet closed and the exhaust is open.When the valve is energized, the inlet is open allowing flow to thecylinder port and the exhaust orifice is blocked. Three-WayNormally Closed Valves are available in Line Connect style (withpiping adapter), and Free Vent style.

Page 36: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9936

3-Way Multi-PurposeN.O.

N.C. COM

N.O.

N.C. COM

ORIFICE Cv STANDARD Valve Body MANIFOLD MOUNTDIAMETER Factor MOPD Grommet OPERATOR Valve Body-Grommet

Body Stop Body Stop (psi) SS Brass SS BrassSeries 1 1/32 1/32 0.035 0.025 150 V141060 V141160 V141360 V161060 V161160

3/64 3/64 0.050 0.065 100 V141061 V141161 V141361 V161061 V1611611/16 1/16* 0.085 0.115 80 V141062 V141162 V141362 V161062 V1611625/64 1/16* 0.125 0.115 60 V141063 V141163 V141363 V161063 V1611633/32 1/16* 0.165 0.115 35 V141064 V141164 V141364 V161064 V1611641/8 1/16* 0.240 0.115 20 V141065 V141165 V141365 V161065 V161165

5/32 1/16* 0.285 0.115 10 V141066 V141166 V141366 N/A N/ASeries 2 1/32 1/32 0.035 0.025 175 V241060 V241160 V241360 V261060 V261160

3/64 3/64 0.050 0.065 125 V241061 V241161 V241361 V261061 V2611611/16 1/16 0.085 0.115 100 V241062 V241162 V241362 V261062 V2611625/64 5/64* 0.125 0.140 75 V241063 V241163 V241363 V261063 V2611633/32 5/64* 0.165 0.140 50 V241064 V241164 V241364 V261064 V2611641/8 5/64* 0.240 0.140 25 V241065 V241165 V241365 V261015 V261165

5/32 5/64* 0.285 0.140 15 V241066 V241166 V241366 N/A N/A

ORIFICE Cv STANDARD Valve Body - GrommetDIAMETER Factor MOPD Stainless Steel Brass

Body Stop Body Stop (psi) 1/8" NPTF 1/4" NPTF 1/8" NPTF 1/4" NPTFSeries 3 1/32 1/32 0.035 0.025 175 V341060 V351060 V341160 V351160

3/64 3/64 0.050 0.065 125 V341061 V351061 V341161 V3511611/16 1/16 0.085 0.115 100 V341062 V351062 V341162 V3511625/64 5/64* 0.125 0.145 75 V341063 V351063 V341163 V3511633/32 5/64* 0.165 0.145 50 V341064 V351064 V341164 V3511641/8 5/64* 0.240 0.145 25 V341065 V351065 V341165 V351165

5/32 5/64* 0.290 0.145 15 V341066 V351066 V341166 V3511663/16 5/64* 0.345 0.145 10 V341067 V351067 V341167 V3511671/4 5/64* 0.415 0.145 5 V341068 V351068 V341168 V351168

Series 6 1/32 1/32 0.035 0.025 275 V641060 V651060 V641160 V6511603/64 3/64 0.050 0.065 200 V641061 V651061 V641161 V6511611/16 1/16 0.090 0.115 175 V641062 V651062 V641162 V6511625/64 5/64 0.135 0.180 125 V641063 V651063 V641163 V6511633/32 3/32 0.180 0.210 100 V641064 V651064 V641164 V6511641/8 1/8 0.275 0.240 60 V641065 V651065 V641165 V651165

5/32 1/8 0.370 0.240 40 V641066 V651066 V641166 V6511663/16 1/8 0.455 0.240 25 V641067 V651067 V641167 V6511671/4 1/8 0.650 0.240 15 V641068 V651068 V641168 V651168

* Larger stop orifice available with reduced pressure ratings; consult Norgren.

Page 37: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 37

Three-Way Multi-Purpose (3WMP) - Valve withthree ports, and two orifices. One orifice islocated in the body and the other in the endstop. The three ports are the “NORMALLYOPEN”, “NORMALLY CLOSED” and“COMMON”. When the valve is de-energized,

1/8 PLASTIC BODY PLASTIC VALVE** LOW WATT SpecificationsNPT CV Factor 1/8" NPTF 7/16 - 20 Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

MALE Body Stop FEMALE UNF Body Stop A B C DSeries 1 V131160 0.030 0.025 - 80 - 95

V131161 0.050 0.060 - 25 40 60V131162 0.085 0.105 - - - 20V131163 0.120 0.105 - - - 8V131164 0.150 0.105 - - - -V131165 0.225 0.105 - - - -

N/A 0.270 0.105 - - - -Series 2 V231160 N/A N/A N/A N/A 0.030 0.025 - - 95 130

V231161 0.062 .065 V241761 V221761 0.050 0.060 - - 50 75V231162 0.090 .115 V241762 V221762 0.085 0.105 - - 10 20V231163 N/A N/A N/A N/A 0.120 0.125 - - - 15V231164 0.205 .140 V241764 V221764 0.150 0.125 - - - -V231165 0.245 .140 V241765 V221765 0.225 0.125 - - - -

N/A 0.310 .140 V241766 V221766 0.270 0.125 - - - -

MANIFOLD MOUNT Valve Body LOW WATT SpecificationsOPERATOR Grommet Cv Factor 1.5 Watt 2.0 Watt 2.5 Watt 3.0 Watt

1/8" NPTF 1/4" NPTF Stainless Steel Brass Body Stop A B C DSeries 3 V341360 V351360 0.030 0.025 - - 95 130

V341361 V351361 0.050 0.060 - - 50 75V341362 V351362 0.085 0.105 - - 10 20V341363 V351363 0.120 0.125 - - - 15V341364 V351364 0.150 0.125 - - - -V341365 V351365 0.225 0.125 - - - -V341366 V351366 0.270 0.125 - - - -V341367 V351367 - - - - - -V341368 V351368 - - - - - -

Series 6 V641360 V651360 V661060 V661160V641361 V651361 V661061 V661161V641362 V651362 V661062 V661162V641363 V651363 V661063 V661163V641364 V651364 V661064 V661164V641365 V651365 V661065 V661165V641366 V651366 V661066 V661166V641367 V651367 V661067 V661167V641368 V651368 V661068 V661168

** Plastic Body valves have a maximum pressure rating of 200 PSI.

Note: Series 6 manifold mount 3-Way valves have a 1/4" NPTF adapter as standard. 1/8" NPTF available upon request.

the common port is open to the normally open port. When thevalve is energized, the normally closed port is open allowing flowfrom the common port and the normally open orifice is blocked.Three-Way Multi-Purpose Valves can be used as a 3WNC, 3WNO,or a 3WDC valve. Additionally, this valve can be used to pipe thealternate flow of two different media to one port.

Page 38: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9938

3-Way Normally OpenIN

EXH CYL

IN

EXH CYL

ORIFICE Cv STANDARD Valve BodyDIAMETER Factor MOPD Grommet OPERATOR

Body Stop Body Stop (psi) Stainless Steel BrassSeries 1 1/32 1/32 0.035 0.025 160 V141050 V141150 V141350

3/64 3/64 0.050 0.065 125 V141051 V141151 V1413511/16 1/16* 0.085 0.115 100 V141052 V141152 V1413525/64 1/16* 0.125 0.115 80 V141053 V141153 V1413533/32 1/16* 0.165 0.115 60 V141054 V141154 V1413541/8 1/16* 0.240 0.115 40 V141055 V141155 V141355

5/32 1/16* 0.285 0.115 10 V141056 V141156 V141356Series 2 1/32 1/32 0.035 0.025 200 V241050 V241150 V241350

3/64 3/64 0.050 0.065 150 V241051 V241151 V2413511/16 1/16 0.085 0.115 125 V241052 V241152 V2413525/64 5/64* 0.125 0.140 100 V241053 V241153 V2413533/32 5/64* 0.165 0.140 75 V241054 V241154 V2413541/8 5/64* 0.240 0.140 60 V241055 V241155 V241355

5/32 5/64* 0.285 0.140 25 V241056 V241156 V241356

ORIFICE Cv STANDARD Valve Body - GrommetDIAMETER Factor MOPD Stainless Steel

Body Stop Body Stop (psi) 1/8" NPTF 1/4" NPTFSeries 3 1/32 1/32 0.035 0.025 200 V341050 V351050

3/64 3/64 0.050 0.065 150 V341051 V3510511/16 1/16 0.085 0.115 125 V341052 V3510525/64 5/64* 0.125 0.145 100 V341053 V3510533/32 5/64* 0.165 0.145 75 V341054 V3510541/8 5/64* 0.240 0.145 60 V341055 V351055

5/32 5/64* 0.290 0.145 45 V341056 V3510563/16 5/64* 0.345 0.145 10 V341057 V3510571/4 5/64* 0.415 0.145 5 V341058 V351058

Series 6 1/32 1/32 0.035 0.025 400 V641050 V6510503/64 3/64 0.050 0.065 250 V641051 V6510511/16 1/16 0.090 0.115 200 V641052 V6510525/64 5/64 0.135 0.180 175 V641053 V6510533/32 3/32 0.180 0.210 125 V641054 V6510541/8 1/8 0.275 0.240 85 V641055 V651055

5/32 1/8 0.370 0.240 50 V641056 V6510563/16 1/8 0.455 0.240 35 V641057 V6510571/4 1/8 0.650 0.240 15 V641058 V651058

* Larger stop orifice available with reduced pressure ratings; consult Norgren.

Page 39: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 39

Three-Way Normally Open (3WNO) - Valve withthree ports, and two orifices. One orifice islocated in the body and the other in the endstop. The three ports are the “IN”, “EXHAUST”

MANIFOLD MOUNT Valve Body 1/8 PLASTIC BODY PLASTIC VALVE**Grommet NPT Cv FACTOR 1/8" NPTF 7/16 - 20

Stainless Steel Brass Male Body Stop FEMALE UNFSeries 1 V161050 V161150 V131150

V161051 V161151 V131151V161052 V161152 V131152V161053 V161153 V131153V161054 V161154 V131154V161055 V161155 V131155

N/A N/A N/ASeries 2 V261050 V261150 V231150 N/A N/A N/A N/A

V261051 V261151 V231151 0.062 0.065 V241751 V221751V261052 V261152 V231152 0.090 0.115 V241752 V221752V261053 V261153 V231153 N/A N/A N/A N/AV261054 V261154 V231154 0.205 0.140 V241754 V221754V261055 V261155 V231155 0.245 0.140 V241755 V221755

N/A N/A N/A 0.310 0.140 V241756 V221756

STANDARD Valve Body - Grommet MANIFOLD MOUNT Valve BodyBrass OPERATOR Grommet

1/8" NPTF 1/4" NPTF 1/8" NPTF 1/4" NPTF Stainless Steel BrassSeries 3 V341150 V351150 V341350 V351350

V341151 V351151 V341351 V351351V341152 V351152 V341352 V351352V341153 V351153 V341353 V351353V341154 V351154 V341354 V351354V341155 V351155 V341355 V351355V341156 V351156 V341356 V351356V341157 V351157 V341357 V351357V341158 V351158 V341358 V351358

Series 6 V641150 V651150 V641350 V651350 V661050 V661150V641151 V651151 V641351 V651351 V661051 V661151V641152 V651152 V641352 V651352 V661052 V661152V641153 V651153 V641353 V651353 V661053 V661153V641154 V651154 V641354 V651354 V661054 V661154V641155 V651155 V641355 V651355 V661055 V661155V641156 V651156 V641356 V651356 V661056 V661156V641157 V651157 V641357 V651357 V661057 V661157V641158 V651158 V641358 V651358 V661058 V661158

** Plastic Body valves have a maximum pressure rating of 200 PSI.

Note: Series 6 manifold mount 3-Way valves have a 1/4" NPTF adapter as standard. 1/8" NPTF available upon request.

and “CYLINDER”. When the valve is de-energized, the inlet is openand the exhaust is closed. When the valve is energized, theexhaust is open allowing flow from the cylinder port and the inletorifice is blocked.

Page 40: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9940

3-Way Directional ControlN.O.

N.C. IN

N.O.

N.C. IN

ORIFICE Cv STANDARD Valve BodyDIAMETER Factor MOPD Grommet OPERATOR

Body Stop Body Stop (psi) Stainless Steel BrassSeries 1 1/32 1/32 0.035 0.025 230 V141070 V141170 V141370

3/64 3/64 0.050 0.065 160 V141071 V141171 V1413711/16 1/16* 0.085 0.115 120 V141072 V141172 V1413725/64 1/16* 0.125 0.115 80 V141073 V141173 V1413733/32 1/16* 0.165 0.115 60 V141074 V141174 V1413741/8 1/16* 0.240 0.115 35 V141075 V141175 V141375

5/32 1/16* 0.285 0.115 20 V141076 V141176 V141376Series 2 1/32 1/32 0.035 0.025 275 V241070 V241170 V241370

3/64 3/64 0.050 0.065 200 V241071 V241171 V2413711/16 1/16 0.085 0.115 150 V241072 V241172 V2413725/64 5/64* 0.125 0.140 100 V241073 V241173 V2413733/32 5/64* 0.165 0.140 75 V241074 V241174 V2413741/8 5/64* 0.240 0.140 50 V241075 V241175 V241375

5/32 5/64* 0.285 0.140 25 V241076 V241176 V241376

ORIFICE Cv STANDARD Valve Body - GrommetDIAMETER Factor MOPD Stainless Steel

Body Stop Body Stop (psi) 1/8" NPTF 1/4" NPTFSeries 3 1/32 1/32 0.035 0.025 275 V341070 V351070

3/64 3/64 0.050 0.065 200 V341071 V3510711/16 1/16 0.085 0.115 150 V341072 V3510725/64 5/64* 0.125 0.145 100 V341073 V3510733/32 5/64* 0.165 0.145 75 V341074 V3510741/8 5/64* 0.240 0.145 50 V341075 V351075

5/32 5/64* 0.290 0.145 25 V341076 V3510763/16 5/64* 0.345 0.145 10 V341077 V3510771/4 5/64* 0.415 0.145 5 V341078 V351078

* Larger stop orifice available with reduced pressure ratings; consult Norgren.

Page 41: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Valve Ordering Information

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 41

** Plastic Body valves have a maximum pressure rating of 200 PSI.

Three-Way Directional Control (3WDC) - Valvewith three ports, and two orifices. One orifice islocated in the body and the other in the endstop. The three ports are the “NORMALLYOPEN”, “NORMALLY CLOSED” and “IN”. When

MANIFOLD MOUNT Valve Body 1/8 PLASTIC BODY PLASTIC VALVE**Grommet NPT Cv FACTOR 1/8" NPTF 7/16 - 20

Stainless Steel Brass Male Body Stop FEMALE UNFSeries 1 V161070 V161170 V131170

V161071 V161171 V131171V161072 V161172 V131172V161073 V161173 V131173V161074 V161174 V131174V161075 V161175 V131175

N/A N/A N/ASeries 2 V261070 V261170 V231170 N/A N/A N/A N/A

V261071 V261171 V231171 0.062 0.065 V241771 V221771V261072 V261172 V231172 0.090 0.115 V241772 V221772V261073 V261173 V231173 N/A N/A N/A N/AV261074 V261174 V231174 0.205 0.140 V241774 V221774V261075 V261175 V231175 0.245 0.140 V241775 V221775

N/A N/A N/A 0.310 0.140 V241776 V221776

STANDARD Valve Body - Grommet MANIFOLD MOUNT Valve BodyBrass OPERATOR Grommet

1/8" NPTF 1/4" NPTF 1/8" NPTF 1/4" NPTF Stainless Steel BrassSeries 3 V341170 V351170 V341370 V351370

V341171 V351171 V341371 V351371V341172 V351172 V341372 V351372V341173 V351173 V341373 V351373V341174 V351174 V341374 V351374V341175 V351175 V341375 V351375V341176 V351176 V341376 V351376V341177 V351177 V341377 V351377V341178 V351178 V341378 V351378

the valve is de-energized, the inlet is open to the normally openport. When the valve is energized, the normally closed port isopen allowing flow from the inlet port and the normally openorifice is blocked. Three-Way Directional Control valve can beused to divert flow from one port to another.

Page 42: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Value-Added Valve Options

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9942

Take the opportunity to reduce multiple parts and multipleprocesses to one complete valve assembly purchase. Have all yourfittings Teflon® taped, installed and leadwire trimmed to the properlength and the connector of your choice attached.

Norgren Incorporated offers a wide array of fittings and electricalterminations for a complete manifold or solenoid valve assembly.We offer pre-taped (Teflon®) fittings, factory installed and leakchecked, and shipped to you under one part number.

Let Norgren show you the benefits of part number consolidation,from overall part cost to internal cost and time reduction.

Features:• Reduce your inventory requirements• Plan for one part rather than multiple components• Shift quality responsibility for complete assembly to Norgren

Value-Added Valve Options

Take Norgren Service Another Step… or Two

Whether you are considering design changesof an existing product or a new productdevelopment, contact Norgren early in thedevelopment stage. Norgren can bring a highlevel of application expertise and technicalsupport to your design project.

We can evaluate the entire system, includingpressure controls, fittings, transducers, gaugesand overall pack aging requirements, to provideyou with a cost-effective system rather than ajigsaw puzzle of components.

We provide support from design throughinstallation. When product design is completed,tested and approved, Norgren will talk to yourmanufacturing personnel concerning packagingand handling requirements.

Don’t wait any longer to contact Norgren withyour requirements!

Teflon® is a registered trademark of E.I. Dupont De Nemours Co.

Page 43: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 43

All Dimensions in Inches (mm)

Standard Valve

N

H

K

E

D

C

B

FR

A

M

G

D

C

BFH

G

E

A

A B C D E F G H K M N R

Series .99 .28 1.33 2.12 2.47 1.12 .64 33-1/2° .73 1/8-27#8-32

1/8-271 (25) (7) (33) (54) (63) (29) (16) (19) NPTF

UNC xNPTF1/4 MFT

Series .99 .28 1.51 2.32 2.66 1.12 .64 33-1/2° .73 1/8-27#8-32

1/8-272 (25) (7) (38) (59) (68) (29) (16) (19) NPTF

UNC xNPTF1/4 MFT

Series 1.18 .355 1.65 2.46 2.80 1.19 .78 .91 1/8-27#10-32

1/8-273 (30) (9) (42) (62) (71) (30) (20)

41°(23) NPTF

UNF xNPTF1/4 MFT

1/4-18#8-32

or

0°NPTF

UNC x1/4-18

1/4 MFTNPTF

Series 1.62 .344 G-2.04 2.86 3.54 1.58 1.03 1.24 1/8-27 1/8-276 (41) (9) (52) (73) (90) (40) (26) 45° (31) NPTF #10-32 NPTF

or UNF x orC-1.87 1/4-18 5/16 1/4-18(48) NPTF MFT NPTF

A B C D E F H M N P RSeries .94 .27 2.12 2.47 .64 1.12 1.32 1/8-27 NPTF 1/8-27 NPTF .44 (11) 1/8-27 NPTF

1 (24) Hex (7) (54) (63) (16) (29) (33) 1/4-18 NPTF .56 (14)Series .94 .27 2.32 2.66 .64 1.12 1.51 1/8-27 NPTF 1/8-27 NPTF .44 (11) 1/8-27 NPTF

2 (24) Hex (7) (59) (68) (16) (29) (38) 1/4-18 NPTF .56 (14)

A B C D E FSeries 1 2.13 (54) 1.33 (34) .20 (5) 2.63 (67) 1.45 (37) 1.93 (49)Series 2 2.13 (54) 1.52 (39) .20 (5) 2.63 (67) 1.45 (37) 1.93 (49)Series 3 2.13 (54) 1.66 (42) .20 (5) 2.63 (67) 1.66 (42) 2.08 (53)Series 6 2.13 (54) 1.97 (50) .20 (5) 2.63 (67) 2.15 (55) 2.68 (68)

13/16-32UN-2A

Leadwire#24 AWG

#10-32 UNF-2B

1.29

(33

)

.75 (19)

.80 (20)

1.73

(44

)

2x .

21 (

5)

.50 (13)

2X#6-32 x .218 MFT

.42

(11)

2x # 10-32UNF-2B

Leadwire#24 AWG

#10-32 UNF-2B

.74 (19)

.80 (20)

D

C

B

HP

FR

N

E

A

M

Bracket Dimensions

Hex Male Valve Standard

Mounting Brackets

E

F

A D

C

B

Operator Standard A B C D E F G HSeries 1.02 .52 1.32 1.67 .64 1.12 3/4-32 UNEF 1/8-27 NPTF

1 (26) (13) (34) (42) (16) (29)Series 1.02 .71 1.52 1.86 .64 1.12 3/4-32 UNEF 1/8-27NPTF

2 (26) (18) (39) (47) (16) (29)Series 1.16 .71 1.52 1.86 .78 1.19 3/4-32 UNEF 1/8-27 NPTF

3 (30) (18) (39) (47) (20) (30) or1/4-18 NPTF

Series 1.64 G- 1.79 2.48 1.03 1.58 1-32 UN 1/8-27 NPTF6 (42) .97 (25) (46) (63) (26) (40) or

C- 1/4-18NPTF.80 (20)

Norgren Jr. Standard

Norgren Jr.Operator

Page 44: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9944

All Dimensions in Inches (mm)

Manifold Mount Valve

Norgren Jr.Manifold Mount

Manifold Mount Interface

Plastic Body Standard

D

C

N

B

FR

M

E

A

1.73

(44

)

.42

(11)

Leadwire#30 AWG

#10-32 UNF-2A.74 (19)

.80 (20)

#10-32 UNF-2B

.16

(4)

A B C D E F M N RSeries .99 1.07 1.87 2.22 .64 1.12 5/16 24 UNF .25 1/8-27 NPTF

1 (25) (27) (48) (56) (16) (29) (6)Series .99 1.26 2.07 2.41 .64 1.12 5/16 24 UNF .25 1/8-27 NPTF

2 (25) (32) (53) (61) (16) (29) (6)Series 1.62 G- 2.55 3.23 1.03 1.58 1/2 20 UNF .31 1/8-27 NPTF

6 (41) 1.73 (44) (65) (82) (26) (40) (8) orC- 1/4-18 NPTF

1.56 (40)

A B RSeries 5/16 - 24 UNF-2B .09 .311 & 2 x .26 MFT (2) (8)

Series 1/2 - 24 UNF-2B .27 .516 x .32 MFT (7) (13)

A B C D E F G H K L M N Rø 1.62 x .53

.42 .66 1.85 2.67 3.00 1.12 .64 1.00 .63 1.52 1/8-27 Deep for #10 1/8-27(11) (17) (47) (68) (76) (29) (16) (25) (16) (39) NPT self-tapping NPTFMax screws

Female PortingA B C D E F G H K L M N R

ø 1.62 x .53.42 .66 1.85 2.67 3.00 1.12 .64 1.00 .63 2.00 7/16-20 Deep for #10 1/8-27(11) (17) (47) (68) (76) (29) (16) (25) (16) (51) UNF-2A self-tapping NPTFMax screws

Male Porting

A B Max

R

40

Norgren Jr. Manifold Mount Interface

A B RLow 10-32 UNF-2B .08 .22Watt x .150 MFT (2) (5)

A B Max

R

40

NOTE: A is underseat connection**B is overseat connection***

NOTE: A is underseat connection**B is overseat connection***

D

E

B

H K

C

FR

M

G

L

N

A

E

D

B

C

FR

M

G

A

H K

L

Page 45: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 45

All Dimensions in Inches (mm)

Norgren Jr. Series Manifold DimensionsManifold Mount Valve Type Manifold

Operator Mounting Type Manifolds - Including Isolation Type Manifolds

.50

(13)

.14

(4)

.14 (4) #10-32 UNF-2B Ports

.63 (16) .85 (22) Typ

.14

(4)

.14 (4)

.27

(7)

2.25

(57

)

.75

(19)

.29

(7)

#10-32 UNF-2B Ports 1/8-27 NPTF

1/8-27 NPTF1.00 (25)

.80 (20)

.50 (13)

.50

(13)

.14

(4)

.14 (4) #10-32 UNF-2B Ports

2x .14 (2) Thru

.63 (16) .85 (22) Typ

.14

(4)

.14 (4)

.27

(7)

Typ

1.85

(47

)

.75

(19)

.29

(7)

#10-32 UNF-2B Ports 1/8-27 NPTF1/8-27 NPTF1.00 (25)

.80 (20) Typ

.50 (13)

Page 46: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9946

All Dimensions in Inches (mm)

Electronic/Pneumatic Interface CardsDimensions & Specifications

ElectricalCoil Suppression Diode: Type 1 N4128Total Load Per Solenoid: 135 MA - 5 VDC(Solenoid & L.E.D.) 60 MA - 12 VDC

50 MA - 15 VDC37 MA - 124 VDC

Working Range: 5 VDC 4.5V - 6V12 VDC 10.5V - 13V15 VDC 13V - 17V24 VDC 21V - 26V

Printed Circuit BoardThickness: .093FB4 Glass/EPOXYPlating: Tin/Lead Copper Clad

ModelDimension 8 Station 12 Station 16 Station

A 6.25 8.25 10.25(159) (210) (260)

B 5.75 7.75 9.75(146) (197) (248)

Valve Number

1 1 1 12 2 2 23 3 3 34 4 4 45 5 5 56 6 6 67 7 7 78 8 8 89 9 9

10 10 1011 11 1112 12 1213 1314 1415 1516 16

17-18 No Connection19-20 Ground (Used only with Manual Overrides)21-23 No Connection24-25 Common Positive Voltage

LED 1

R1

D1

1

19 & 20

24 & 25Solenoid

S1

5.00

(12

7)

6.00

(15

2)

B

DB 25 PinConnector

4x .14 (2) ThruMounting Holes Connector

Manual Overide(Optional)

Outlet Ports#10-32 UNF

Solenoid Valve

Supply Port1/8-27 NPTF

LED Status Indicator

External PowerSupply Input

A

Dimension and Pin Chart

Page 47: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 47

All Dimensions in Inches (mm)

Manifold DimensionsManifold Mount Valve Type Manifolds

Operating Mounting Type Manifolds

P

N

M

W

T

R

Z

Z

S

K

L

YD

D

H

D D

F

A B

P

N

M

W

T

R

Z

S

KZ

C

C

J J

J

D

F

A B

L

J

A B D F H K L M N P R S T W Y ZSeries .28 1/8-27

1 .75 1.06 .14 .52 .15 1.25 .52 (7) 2.62 2.97 1.12 .64 1.82 .75 .41 NPTF(19) (27) (4) (13) (4) (32) (13) .34 (67) (75) (29) (16) (46) (19) (10) 1/4-18

(9) NPTFSeries .28 1/8-27

2 .75 1.06 .14 .52 .15 1.25 .52 (7) 2.82 3.16 1.12 .64 2.01 .75 .41 NPTF(19) (27) (4) (13) (4) (32) (13) .34 (72) (80) (29) (16) (51) (19) (10) 1/4-18

(9) NPTFSeries .38 2.73* 1/8-27

6 .94 1.69 .19 .84 .20 1.75 .84 (10) 3.55 4.23 1.58 1.03 (69) 1.00 .56 NPTF(24) (43) (5) (21) (5) (45) (21) .44 (90) (108) (40) (26) 2.56** (25) (14) 1/4-18

(11) (65) NPTF

A B C D F J K L M N P R S T U W Y ZSeries .78 1.06 .16 .19 .52 .16 1.00 .50 .42 2.33 2.67 1.12 .64 1.52 #8-32 UNC 1.00 .58 1/8-27

1 (20) (27) (4) (5) (13) (4) (25) (13) (10) (59) (68) (29) (16) (39) x 1/4 MFT (25) (15) NPTFSeries .78 1.06 .16 .19 .52 .16 1.00 .50 .42 2.52 2.87 1.12 .64 1.72 #8-32 UNC 1.00 .58 1/8-27

2 (20) (27) (4) (5) (13) (4) (25) (13) (10) (64) (73) (29) (16) (44) x 1/4 MFT (25) (15) NPTF

* = Grommet ** = Conduit

Page 48: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Dimensions

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9948

All Dimensions in Inches (mm)

Manifold Dimensions Including Cartridge Inserts

M

N

P

R

S

L Z Z

W

T

Y

K

F

D

C

A

B

D

C

H

A B C D F H K L M N P R S T W Y ZSeries .92 1.06 .30 .14 .52 .15 1.50 .52 .33 2.87 3.53 1.12 .64 2.07 1.00 .60

1/41 (23) (27) (8) (4) (13) (4) (38) (13) (8) (73) (90) (28) (16) (53) (25) (15)1.10 1.06 .30 .14 .60 .15 1.75 .60 .38 2.87 3.69 1.12 .64 2.07 1.00 .62

3/8(28) (27) (8) (4) (15) (4) (45) (15) (10) (73) (94) (28) (16) (53) (25) (16)Series .92 1.06 .30 .14 .52 .15 1.50 .52 .33 3.07 3.71 1.12 .64 2.26 1.00 .60

1/42 (23) (27) (8) (4) (13) (4) (38) (13) (8) (78) (99) (28) (16) (57) (25) (15)1.10 1.06 .30 .14 .60 .15 1.75 .60 .38 3.07 3.88 1.12 .64 2.26 1.00 .62

3/8(28) (27) (8) (4) (15) (4) (45) (15) (10) (78) (99) (28) (16) (57) (25) (16)Series 2.73*

6 1.17 1.69 .19 .19 .84 .20 2.00 .84 1.17 3.55 4.23 1.58 1.03 (69) 1.00 .551/4(30) (43) (5) (5) (21) (5) (51) (21) (30) (90) (107) (40) (26) 2.56** (25) (14)

(65)2.98*

1.41 1.69 .19 .19 .84 .20 2.25 .84 1.41 3.80 4.65 1.58 1.03 (76) 1.25 .783/8(36) (43) (5) (5) (21) (5) (57) (21) (36) (97) (118) (40) (26) 2.81** (32) (20)

(71)2.98*

1.41 1.69 .19 .19 .84 .20 2.25 .84 1.41 3.80 4.65 1.58 1.03 (76) 1.25 .781/2(36) (43) (5) (5) (21) (5) (57) (21) (36) (97) (118) (40) (26) 2.81** (32) (20)

(71)

* = Grommet ** = Conduit

Page 49: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Application Considerations

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 49

Cv = GPM

∆PS.G.

1. Find pressure differential on horizontal axis.

2. Draw vertical line to intersect with curve; at this point draw hori-zontal line to vertical axis. This is the flow for a valve with a Cvfactor of 1.

3. Now, use Norgren’s Cv factor from the catalog listing, and multi-ply this Cv by the flow from step two above. This is the flowthrough the specific valve you have selected.

4. If the media is not water, multiply the flow by a correction factor.Examples of correction factors are:

Gasoline 1.200Ethyl Alcohol 1.120MIL-H-5606A

Hydro-oil 1.087

Other Fluids = 1S.G.

0

5

10

15

20

25

30

35

40

100 200 300 400 500

PRESSURE DIFFERENTIAL (PSI)

600 700 800 900 1000

FLOWIN GPM@ 70°F

Liquid Flow CalculationsEXAMPLEMedia: GasolinePressure differential: 200Cv factor - Norgren Series 1 valve, 1/32 orifice,

2-Way Normally Closed:.035Pressure Differential

on Chart = 200Water flow x Cv factor = 14 x .035 = 0.490Valve Flow with water

x Correction factor = 0.490 x 1.200 = .588 GPM

This is the flow of gasoline through a NorgrenPIN 141040 valve under these conditions.

Page 50: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Application Considerations

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9950

Air/Gas Flow Calculations1. Find back pressure on horizontal axis.

2. Draw vertical line to intersect with operating pressure curve; atthis point draw horizontal line to vertical axis. This is the flow fora valve with a Cv factor of 1 in SCFM (standard cubic feet perminute).

3. Use the Cv factor from the catalog listing, and multiply this Cvby the flow from step two above. This is the air flow through thespecific valve you have selected.

4. If the media is not air multiply the flow by a correction factor.Examples of correction factors are:

Helium 2.69Hydrogen 3.85Methane 1.33Oxygen .95Propane .80

Other Fluids = 1S.G.

0

20

40

60

80

100

120

140

160

20

20

40

60

80100

120

140

160

180

200

220

240

40 60 80 100

PRESSURE DIFFERENTIAL (PSI)

120 140 160 180 200

FLOWIN SCFM@ 70°F

EXAMPLEMedia: OxygenBack Pressure: 100Operating Pressure: 120Cv factor - Norgren Series 6 valve, 3/64 orifice,

2-Way Normally Closed:.050

Back Pressure on Chart = 100Operating Pressure Curve = 120Air flow x Cv factor = 50 x .050 = 2.50Valve Flow with air

x Correction factor = 2.50x.95 = 2.375 SCFM

This is the flow of oxygen through a NorgrenPIN 651111 valve under these conditions.

Page 51: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Liquid Level Switches Background

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 51

High Quality Liquid Level Switches Engineered for Extended Service

Design Considerations

• Pressure• Temperature• Mounting• Termination• Media Characteristics, such as

- Specific gravity- Corrosive characteristics- Viscosity

• Actuation Point(s)• Materials of construction• Switch life/Switch load

Norgren Leveline liquid level switches aredesigned to meet a complete range ofapplication requirements. Norgren has thedesign engineering and application engineeringexpertise to help you select the best levelcontrol for your application.

The switch contact ratings, as listed in theswitch data chart, are based on use with aresistive type load. For applications requiringthe control of an inductive or capacitance load,additional interface circuitry may be required.Please contact Norgren for assistance or tohave a life-cycle test performed on your loadwith Norgren Leveline switches.

HermeticallySealed

Reed SwitchPermanent

Magnet

Float

Operation

The hermetically sealed reed switch located inside the stem isactuated by a magnetic field created by a magnet equipped float.As the float rises and falls the magnetic field passing the switch inthe stem causes the switch to either close or open.

Norgren Leveline switches can be mounted from tank top or tankbottom or can be adapted for side mounting. Switches will operatenormally with up to a 30° tilt from vertical .

Most single point switches operate in either a Normally Open (NO)or Normally Closed (NC) mode. Selecting the mode is as easy asremoving the retaining clip and reversing the float on the stem.Norgren switches are shipped normally open as standard.However, some are non reversible and must be ordered as NO, NCor SPDT.

Design Flexibility

Interface Protection Many Norgren Leveline models can be modified to detectthe level of two dissimilar liquids such as oil and water.

Mounting StylesOther mounting configurations are available such asflanges, bent stem, different NPT, straight thread andmetric size mounting plugs.

Terminations A variety of wire terminations, custom lead lengths, cablejackets and connectors are also available.

In addition to single point detectors, Norgren also offers multipointproducts for OEM applications. Complete the Application InquirySheet on page 81 and fax to 303-795-9487 or call Norgren at 303-794-2611.

Page 52: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Electrical Data

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9952

Electrical Data

Norgren Standard Reed Switches are SPST orSPDT.The Diagrams Below Show the Typical Wiring.

Form A SPST - Single Pole / Single Throw

Normally Open Dry

Normally Closed Dry

Form C SPDT - Single Pole / Double Throw

SPDT Dry Condition

Each Norgren level switch varies in rating depending on the unit,see the chart below for electrical ratings.

Switch Ratings Max - Resistive Loads

NOTE: Above ratings are for resistive loads only

RED

RED

RED

RED

BLACK

REDN.O.

N.C.COM.WHITE/RED

Contact Rating Volts Amps AC Amps DC0-50 .20 .13

10 VA 120 .08 .05240 .04 N/A0-50 .40 .30

20 VA 120 .17 .13240 .08 .060-50 .50 .50

50 VA 120 .41 .41240 .20 .20

100 VA120 .83 N/A240 .41 N/A

The reed switch is designed for reliability tomillions of cycles. To ensure long life andrepeatability, see the contact protectioninformation below.

Contact ProtectionIn order to take advantage of the long life,highly reliable characteristics of a reed switch, itis essential to provide protection whenswitching inductive loads.

When current is interrupted, the inductance ofthe load generates a high frequency voltage,which appears across the switch contacts. If thevoltage is large enough, it can cause arcing.Arcing can cause the contacts to weld to eachother resulting in unreliable switchingperformance. It isessential toprotect the circuitby suppressingthe voltage toprevent arcing.This can easilybe accomplishedthrough the useof a diode for DCcircuits (Figure 1)and a resistor-capacitor networkfor AC circuits(Figure 2).

Contacts

Magnet

N

S

HermeticallySealed Glass

Common

Magnet

N

S

HermeticallySealed Glass

NormallyOpen Blade

NormallyClosed Blade

+ -

ReedSwitch

InductiveLoad

Figure 1D.C. Contact Protection

Figure 2A.C. Contact Protection

1N4004

+ -

ReedSwitch

InductiveLoad

Page 53: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 53

All Dimensions in Inches (mm)

LS 1 Series Level SwitchesCompact, Rugged,Yet Economical!The LS 1 Series of liquid level switches from Norgren provide a reliable, compact, low cost solution to liquid-level controlfor the selective OEM. This family of plastic level switches offers a broad variety of answers to many of today’s demandingapplications. Whether your problem is size, material compatibility, or wave motions falsely actuating switches, your answershould be found on these pages or through a quick conversations with Norgren. A variation to these standards will surelysolve the most discriminating application.

FEATURES:• Small, compact size with small displacement• Highly reliable, yet inexpensive• Seamless cellular construction• Temperature range up to 225°F• Excellent chemical resistance• Material is FDA Approved• Unique hex designed stem

SPECIFICATIONS:

MAXIMUM PRESSURE @70° FFoamed Float 150 PSI (10.3 bar)Hollow Float 10 PSI (.69 bar)

TEMP. OPERATING RANGEFoamed Float -40° to 150° F (-40° to 66° C)Hollow Float (PBT) -40° to 225° F (-40° to 107° C)

LEADWIREPolypro Units 22 AWG, 24" longPBT Units 22 AWG, 24" long

RECOMMENDED MINIMUM LIQUID SP GRFoamed Polypro Float .72PBT Float .65

PolypropyleneFoamed Float

PBTHollow Float

1.00

(25

)

A

1.58

(40

)

1.00 (25)

9/16 Hex

1/8 NPT

9/16 Hex

7/16-20 UNF

9/16 Hex

3/8-16 UNC

OtherPart Stem Float Wetted Switch

Number MTG Material Material Parts RatingV0255-024† 1/8" NPT Polypro Polypro Polypro 20VA*V0342-024 1/8" NPT Polypro Buna Polypro 20VA*V0506-024† 1/8" NPT Polypro Polypro 316 SS 10VAV0507-024† 1/8" NPT Polypro Polypro Polypro 10VAV0615-024† 7/16-20 UNF Polypro Polypro Polypro 20VA*V0689-024† 1/8" NPT Polypro Polypro Polypro 3VA SPDTV1072-024 7/16-20 UNF PBT PBT PBT 20VA*V1073-024 1/8" NPT PBT PBT PBT 20VA*

LS 1 Series Ordering Numbers:

* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC† “NSF Certified” - These products conform to the requirements of NSF Criteria C@ - Special and/or Devices.

- For NSF label add prefix N to the part number when ordering.

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

PolypropyleneHollow Float

Page 54: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9954

All Dimensions in Inches (mm)

FEATURES:• All Polypropylene construction ideal for beverage dispensing and

ice machines• Compact size allows for minimum displacement• Easily adaptable to other switch types and float combinations for

OEM applications

SPECIFICATIONS:MAXIMUM PRESSURE @70° F

Foamed Float 150 PSI (10.3 bar)Hollow Float 10 PSI (.69 bar)

TEMP. OPERATING RANGEFoamed Float -40° to 150° F (-40° to 66° C)Hollow Float (PP) -40° to 150° F (-40° to 66° C)Hollow Float (PBT) -40° to 225° F (-40° to 107° C)

LS 1 Series with Slosh ShieldThe LS 1 Series with Slosh Shield Provides a Means of Dampening Turbulent Fluids…

FEATURES:• Ultra compact size fits through small bottle or tank openings• Seamless cellular construction for a rugged float design• Ideal for food and beverage applications• Unique hex stem design minimizes potential for liming

Specifications

Mini LS 1 Series Ordering Numbers:

Maximum Pressure 150 PSI (10.3 bar) @ 70°FTemp. Operating Range -40°F to 150°F (-40° to 66°C)Mounting 1/8" NPT or 7/16 - 20 UNFLeads 22 AWG, 24" longRecommended Minimum Liquid SP GR .90Float Material Seamless Cellular PolypropyleneStem and Other Parts Polypropylene

Part Number MTG Material Switch RatingV0763-024† 1/8" NPT Polypro 20VAV1339-024† 1/8" NPT Polypro 10VAV1340-024† 7/16-20 UNF Polypro 20VA

OtherPart Stem Float Wetted Switch

Number MTG Material Material Parts RatingV1347-001† 1/8" NPT Polypro Polypro Polypro 20VAV1347-002† 7/16-20 UNF Polypro Polypro Polypro 20VAV1347-003† 1/8" NPT PBT PBT PBT 20VAV1347-004† 7/16-20 UNF PBT PBT PBT 20VAV2841-024 1/8" NPT Polypro Hollow Polypro Polypro 20VAV2842-024 7/16-20 UNF Polypro Hollow Polypro Polypro 20VA

1.00

(25

)A

1.58

(40

)

.75 (19)

9/16 Hex

A

1.58

(40

)

1.38 (35)

9/16 Hex

Mini LS 1 SeriesThe LS 1 Series with a Float Diameter of .75 Fits Into Those Hard to Reach Places…

A - actuation point isapproximately midway offloat travel in liquid with aspecific gravity of 1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

A - actuation point isapproximately midway offloat travel in liquid with aspecific gravity of 1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

LEADWIREPolypro Units 22 AWG, 24" long PBT Units 22 AWG, 24" long

RECOMMENDED MINIMUM LIQUID SP GRFoamed Polypro Float .72Hollow Polypro Float .55PBT Float .65

LS 1 Series with Slosh Shield:

† “NSF Certified” - these products conform to the requirements of NSF Criteria CS - Special and/or Devices.- for NSF label add prefix N to the part number when ordering.

† “NSF Certified” - these products conform to the requirements of NSF Criteria CS - Special and/or Devices.- for NSF label add prefix N to the part number when ordering.

Page 55: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

FEATURES:• Sidemount design fits small vessels• Minimal float travel and displacement• Highly chemical resistant

LS 1 Series - SidemountSidemounted Unit Ideal or Tight Spaces

Single Point LevelsAll Dimensions in Inches (mm)

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 55

FEATURES:• Due to the float shape and displacement, the reed switch is

activated with float riding close to the surface of the liquid• Variety of stem materials to meet your specific requirements• Float can be combined with other floats on a miniature multi-level

control only (see pages 67-68) for a custom liquid level sensor tomeet your needs

• Available in different lead wire lengths, with connectors for OEM’s

Part Stem Float Other SwitchNumber Material Material Wetted Parts Rating

V0508-024 Polyacetal Buna N 316 SS 20VAV0509-024 Polypro Polypro Polypro 20VA

Maximum PressureType B 70 PSI (4.8 bar)Type P 40 PSI (2.8 bar)

Temperature RangeType B -40°F to 176°F (-40° to 80°C)Type P -40°F to 176°F (-40° to 80°C)

Mounting PF 1/4Leads 22 AWG, 24" longRecommended Minimum Type B .60Liquid SP GR Type P .80

Maximum 50 PSI (3.4 bar)Pressure

Temp. Operating -40° to 180°F in Water (-40° to 82°C)Range 40° to 225°F in Oil (-40° to 107°C) (Stainless and Brass)Mounting 1/8" NPT

Part Stem Float Other SwitchNumber Material Material Material Rating

V0768-024 Polypro Buna N 316 SS 20VA N.C.V0769-024 Brass Buna N 316 SS 20VA N.C.V0774-024 316 SS Buna N 316 SS 20VA N.C.

1.22

(31

)

1.26 (32)

2.36 (60)

.87 (22)

PF 1/4

Type B

Type P

Specifications:

LS 1 Series Ultra Low Level:

LS 1 Series Ultra Low LevelWhen You Just Can’t Detect Low Enough - The Norgren Ultra Low Level Switch Can DetectLiquids as Low as 5/8"

1.00

(25

)

1.58

(40

)

1.88 (48)

1/8 NPT

Specifications

LS 1 Sidemount Ordering Numbers

Page 56: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

56 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

LS 11 Plastic Sidemount

● Direct side mounted level controls inPolypropylene and PBT

● All polypropylene construction offers broad fluid compatibility

● Single unit offers normally open or normallyclosed operation

● Mounting available internally or direct external entry

Normally Open Dry Condition:Float rises with liquid level to stop, where upon switch closes.

Normally Closed Dry Condition:Float falls with liquid level to stop, where upon switch closes.

Actuation point is 15° +10° of float arc.

Maximum Pressure 100 PSI (6.9 bar) @ 70°F

Temp. Operating Range-40°F to 150°F (-40° to 66°C) Polypro-40°F to 225°F (-40° to 107°C) PBT

Leads 22 AWG, 24" longRecommended Minimum Liquid SP GR .65

Part Number Mounting Material Switch RatingV1870-024† 1/2" NPT Polypro 20VAV1871-024 1/2" NPT PBT 20VAV1872-024† 5/8-11 UNC Polypro 20VAV1873-024 5/8-11 UNC PBT 20VA

1.90

(48

)

.68

(17)

4.03 (102)

1.00 (25) 2.87 (73)

2.37 (60)

5/8-11 UNC

1.90

(48

)

.68

(17)

4.00 (102)

2.87 (73)

2.37 (60)

1/2" NPT

Specifications

LS 11 Ordering Numbers:

† “NSF Certified” - these products conform to the requirements of NSF Criteria C2 - Special and/or Devices.

- for NSF label add prefix N to the part number when callingAll Dimensions in Inches (mm)

Page 57: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 57

All Dimensions in Inches (mm)

1.00

(25

)A

1.50

(38

)

.85 (22)

1/8 NPT

1/2 Hex

1.00

(25

)

A

1.50

(38

)

1.00 (25)

1/8 NPT

1/2 Hex

Switch Rating SPST 20VAOperating Pressure 1000 PSI Maximum (69.8 bar)Operating Temperature -40° to +300°F (-40 to 149°C)Float Material Teflon®

Other Wetted Materials 300 Series Stainless, EpoxyLeads 22 AWG, 24" longRecommended Minimum Liquid SP GR .75

Part Number Stem Material Switch RatingV1275-024 316 SS 20VA N.O. DRY*V1276-024 316 SS 20VA N.C. DRY*

Part Stem Float Other SwitchNumber Material Material Wetted Parts Rating

V0105-024 316 SS Buna N 316 SS 20VAV0106-024 Brass Buna N 316 SS 20VA

Maximum Pressure 150 PSI (10.3 bar)Temperature Operating Range -40° to 225°F (-40° to 107°C) in oil

to 180°F (82°C) in waterMounting 1/8" NPTLeads 22 AWG, 24" longRecommended Minimum Liquid SP GR .50

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

A - actuation point is approximately midway of floattravel in liquid with a specific gravity of 1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

25 BN Series—Teflon ® FloatNorgren Offers Its 25 BN Series with a Spring Biased TEFLON ® Float for High Pressure Applications

FEATURES:• Small float design (.850 Dia.) provides flexibility for those tight

spaces• Solid Teflon float design for pressures up to 1000 PSI• Variety of stem float combinations to meet your technical and

cost requirements

Specifications:

25 BN Series Ordering Numbers:

* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC ® Teflon is a registered trademark of E.I. Dupont De Nemours Co.

25 BN SeriesBuna N General Purpose Single Point Detector

Specifications:

25 BN Series Ordering Numbers:

FEATURES:• Small, compact size• Precise repeatability• Reliable, long-life performance• Highly resistant to shock and vibration• Stem available in 316 SS or Brass

Page 58: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9958

All Dimensions in Inches (mm)

35 SS SeriesCompact Stainless Steel Detector for High Corrosive, High Temperature ApplicationsFEATURES:• Compact size• Long operating life• Highly resistant to shock and vibration

1.06

(27

)

A

1.50

(38

)

1.10 (28)

1/8 NPT

1/2 Hex

2.95

(75

)

2.00

(50

)

1.06

(27

)

1.10 (28)

1.57 (40).59(15)

PF 1/8

.59(15)

PF 1/8

2.95

(75

)

2.31

(59

)

1.00

(25

)

1.00 (25)

1.57 (40)

Actuation Levelin SG of 1.0

Actuation Levelin SG of 1.0

Maximum Pressure 275 PSI (19.0 bar)Temp. Operating Range -40° to 300°F (-40° to 149°C)Mounting 1/8" NPTLeads 22 AWG, 24" longRecommended Minimum Liquid SP GR .80

Part Stem Float Other SwitchNumber Material Material Wetted Parts Rating

V0107-024† 316 SS 316 SS 316 SS 20VA*V0511-024 Brass 304 SS 316 SS 20VA*

Maximum Pressure SS 275 PSI (19.0 bar)

Buna 150 PSI (10.3 bar)Temp. Operating Range -40° to 300°F (-40 to 149°C)

Buna Float -40° to 225°F (-40 to 107°C) in oil-40° to 180°F (-40 to 82°C) in water

Mounting 3/8 - 24Leads 22 AWG, 24" longRecommended Minimum

Liquid SP GR SS .80 Buna .50

A - actuation point is approximately midway of floattravel in liquid with a specific gravity of 1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

® Teflon is a registered trademark of E.I. Dupont De Nemours Co.* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC† “NSF Certified”- these products conform to the requirements of NSF Criteria

Cs - Special and/or Device.- for NSF label add prefix N to the part number when ordering

Specifications:

35 SS Series Ordering Numbers:

35 SS Series - Sidemount“Bent Stem” Level Control for Mounting thru Tank Walls

FEATURES:• 90° bend allows for side mounting where access to tank top and

bottom is restricted• Available in all 316 SS construction

Specifications:

35 SS Series Sidemount Ordering Numbers:

L1 Dimension is Actuation Level in Liquid Specific Gravity of 1.0

Stainless Steel Floats:L1=2.50 (63.5mm) ±3/16"

Buna Floats:L1=2.75 (6.9mm) ±3/16"

Part Stem Float Other SwitchNumber Material Material Wetted Parts Rating

V2350-024 316 SS 316 SS PH 15-7 MO 20VAV2351-024 316 SS Buna PH 15-7 MO 20VA

V2352-024 Brass 316 SSBeryllium

20VACopper

V2353-024 Brass BunaBeryllium

20VACopper

Page 59: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 59

All Dimensions in Inches (mm)

40 SS Series SidemountDirect Side Mounted Level Controls

Maximum Pressure 400 PSI (27.6 bar)Temp. Operating Range -40° to 300°F (-40 to 149°C)Leads 22 AWG, 24" longRecommended Minimum

Liquid SP GR .58

Part Stem / Float Other Wetted SwitchNumber Material Mounting Material Rating

V1344-001 Brass / Buna Stainless / Epoxy SPST 20VAV1344-002 Brass / Buna Stainless / Epoxy SPST 100VAV1344-003 304 SS / Buna Stainless / Epoxy SPST 20VAV1344-004 304 SS / Buna Stainless / Epoxy SPST 100VAV1344-005 304 SS / 316 SS 316 SS SPST 20VAV1344-006 304 SS / 316 SS 316 SS SPST 100VA

Maximum Pressure 150 PSI (10.3 bar)Temperature -40° to 225°F (-40° to 107°C) in oilOperating Range to 180°F (82°C) in water

Mounting 1/4" NPTLeads 18 AWG, 36" longRecommended Minimum Liquid SP GR .55

Part Stem Other Wetted SwitchNumber Mounting Material Materials Rating

V2723-024 3/8-24 UNF 316 SS 304 SS 20VAV2722-024 1/2" NPT 316 SS 304 SS 20VA

1.88

(48

)

A

2.70

(69

)

1.88 (48)

1/4 NPT

Moisture ResistantShrink Tubing

5/8 Hex

.66

(17)

.69 (18) 3.28 (83)

3/8-24 UNF11/16 Hex

.66

(17)

1.08 (27).31 (8)

4.38 (111)

15/16 Hex1/2 NPT

Specifications:

40 SS Series Sidemount Ordering Numbers:

FEATURES:• Precise repeatability• Ease of installation• Internal and external mounting available

50 BN Moisture Resistant Liquid Level SwitchConstruction Provides Maximum Resistance to Moisture, Condensation or Water.

FEATURES:• Ideal for use in sumps or bilges• Construction can be adapted to other Norgren switches• Dual wall polyolefin shrink tubing resists moisture

Specifications:

Liquid Level Switch Ordering Numbers:

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

Page 60: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9960

All Dimensions in Inches (mm)

50 BN Series LargeLarge Size General Purpose Detector

FEATURES:• Large float provides maximum displacement in high viscosity

fluids• Can be easily extended to multiple float arrangement up to 72"

long (see pages 69-70)• Rugged design for heavy duty service

50 BN Series IntermediateIntermediate Size General Purpose Detector

FEATURES:• Highly reliable, yet inexpensive• Compact, narrow displacement• Stem available in 316 SS or Brass• Long operating life

1.75

(45

)

A

2.50

(64

)

1.19 (30)

1/8 NPT

1/2 Hex

1.75

(45

)

A

2.70

(69

)

1.19 (30)

1/4 NPT

5/8 Hex

1.88

(48

)

A

2.75

(69

)

1.88 (48)

1/4 NPT

5/8 Hex

Maximum Pressure 150 PSI (10.3 bar)Temp. Operating Range -40° to 225°F (-40° to 107°C) in oil

to 180°F (82°C) in waterMounting 1/8" NPT - 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum Liquid SP GR .58

Part Stem Float Other SwitchNumber MTG Material Material Wetted Parts Rating

V0512-024 1/4" 316 SS Buna N 316 SS 100VAV0513-024 1/4" Brass Buna N 316 SS 100VAV0514-024 1/4" 316 SS Buna N 316 SS 20VAV0515-024 1/4" Brass Buna N 316 SS 20VA

OtherPart Stem Float Wetted Switch

Number MTG Material Material Parts RatingV0108-024 1/8" 316 SS Buna N 316 SS 100VAV0109-024 1/8" Brass Buna N 316 SS 100VAV0500-024 1/4" 316 SS Buna N 316 SS 100VAV0501-024 1/4" Brass Buna N 316 SS 100VAV0502-024 1/8" 316 SS Buna N 316 SS 20VAV0503-024 1/8" Brass Buna N 316 SS 20VAV0504-024 1/4" 316 SS Buna N 316 SS 20VAV0505-024 1/4" Brass Buna N 316 SS 20VA

Maximum Pressure 150 PSI (10.3 bar)Temp. Operating Range -40° to 225°F (-40 to 107°C) in oil

to 180°F (82°C) in waterMounting 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum Liquid SP GR .55

Specifications:

50 BN Series Inter. Ordering Numbers:

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

Specifications:

50 BN Series Large Ordering Numbers:

Page 61: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 61

All Dimensions in Inches (mm)

1.88

(48

)

A

2.50

(64

)

1.38 (35)

1/4 NPT

5/8 Hex

Maximum Pressure 70 PSI (4.8 bar)Temp. Operating Range -40° to 300°F (-40 to 149°C)Mounting 1/4" NPTLeads 22 AWG, 24" longRecommended Minimum Liquid SP GR .90

Part Stem Float SwitchNumber Material Material Description Rating

V0111-024 TFE PFA SPST, NO Dry 20VA*V0112-024 TFE PFA SPST, NC Dry 20VA*V0113-024 TFE PFA SPST 3VA

A - actuation point is approximately midway of floattravel in liquid with a specific gravity of 1.0.

UL RecognizedFile No. E 129277

CSA ApprovedFile No. LR 90981

50 TT SeriesTeflon ® Level Detector for High Purity, High Corrosive Applications

FEATURES:• All Teflon® wetted surfaces• PFA float for greater resistance to corrosives• Low particulate generation• Chemically inert

Specifications:

50 TT Series Ordering Numbers:

* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC® Teflon is a registered trademark of E.I. Dupont De Nemours Co.

Page 62: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9962

All Dimensions in Inches (mm)

50 SS SeriesStainless Steel Detector for High Pressure, Corrosive and High Temperature Applications

Features:• All stainless steel wetted surfaces• High resistance to corrosive chemicals• Operates in high temperatures• Operates in high pressure environments.

50 SS Series Low Specific GravityBuoyant Float Design for Media with Specific Gravity as Low as .40

Features:• Ideal for use as a high, low or intermediate level alarm in the

storage of propane and butane• Float design can be adapted to Norgren multi-level configuration

for total control• Temperature range of -40° F to 300° F

A

4.50

(11

4)

1/2 NPT

7/8 Hex

3.50 (89)

A

2.70

(69

)

2.00

(51

)

1/4 NPT

5/8 Hex

2.15 (55)

Maximum Pressure 300 PSI (20.7 bar)Temp. Operating Range -40° to 300°F (-40° to 147°C)Mounting 1/2" NPTLead Wires 18 AWG, 24" longRecommended Minimum Liquid SP GR .40

Part Stem / Float Other Wetted SwitchNumber Material Materials Rating

V1348-001 Brass / 316 SS Stainless Steel SPST 20VAV1348-002 Brass / 316 SS Stainless Steel SPST 100VAV1348-003 Brass / 316 SS Stainless Steel SPDT 20VAV1348-004 316 SS / 316 SS Stainless Steel SPST 20VAV1348-005 316 SS / 316 SS Stainless Steel SPST 100VAV1348-006 316 SS / 316 SS Stainless Steel SPDT 20VA

Maximum Pressure 750 PSI (51.7 bar)Temp. Operating Range -40° to 300°F (-40 to 149°C)Mounting 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum Liquid SP GR .73

Part Stem Float Other SwitchNumber Material Material Wetted Parts Rating

V0110-024† 316 SS 316 SS 316 SS 100VAV0110-024 Brass 316 SS 316 SS 100VAV0110-024† 316 SS 316 SS 316 SS 20VAV0110-024 Brass 316 SS 316 SS 20VA

† “NSF Certified”- these products conform to the requirements of NSFCriteria C2 - Special and/or Devices.

- for NSF label add prefix N to the part number when ordering.

Specifications:

Low Gravity Float Ordering Numbers:

A - actuation point isapproximately midway offloat travel in liquid with aspecific gravity of 1.0.

Specifications:

50 SS Series Ordering Numbers:

A - actuation point isapproximatelymidway of float travelin liquid with aspecific gravity of1.0.

Page 63: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 63

All Dimensions in Inches (mm)

���

3.75

(95

)

1/8 NPT or 3/8-24 THD

1/4 NPT 1/4 NPT1.63 (41)

4.03

(10

2)

5.63

(14

3)

2.00

(51

)

.44

(11)

1/2 NPT

3/4 NPT

3/4 NPTInlet

2.00 (51)

2 NPT

Maximum Pressure 50 PSI (3.4 bar)Temp. Operating Range 0° to 120°F (-18 to 49°C)Port Sizes Bottle 1/8" NPT or 3/8-24 2B THD

Body 1/4" NPTLeads 22 AWG, 24" longWetted Materials Body Aluminum

Housing PolycarbonateFluorocarbon316 SS

Part Number Float Type Switch Type P/N with J-BoxV1264-101 Buna N 20VA SPST 1264-201V1264-102 316 SS 20VA SPST 1264-202V1264-103 Buna N 100VA SPST 1264-203V1264-104 316 SS 100VA SPST 1264-204V1264-105 Buna N 20VA SPDT 1264-205V1264-106 316 SS 20VA SPDT 1264-206

Maximum Pressure 400 PSI (27.6 bar) @ 70°F (21.1°C)Temperature Range -40° to 300°F SS Float (40°c to 149°C)

(40°c to 149°C) -40° to 225°F in oil - Buna-N Float(40°C to 107°C) -40° to 180°F in water - Buna-N Float

Port Size 3/4" NPTLeads 18 AWG, 24" longWetted Materials Housing - Bronze, Beryllium Copper, Brass, 316 SS or Buna N

Part Stem Float Top SwitchNumber Material Material Port Rating

V0770-024 Polypro Polypro 1/8" NPT 20VAV0771-024 Brass Buna N 1/8" NPT 20VAV0772-024 316 SS Buna N 1/8" NPT 20VAV0773-024 316 SS 316 SS 1/8" NPT 20VAV2354-024 Polypro Polypro 3/8-24 UNF 20VAV2355-024 Brass Buna N 3/8-24 UNF 20VAV2356-024 316 SS Buna N 3/8-24 UNF 20VAV2357-024 316 SS 316 SS 3/8-24 UNF 20VA

Note: SPST switches are shipped in a normally open dry conditions.Logic can be switched by removing grip ring and reversing float.

Bottle LevelNorgren Keeps You in Control with Level Detection that You Can Actually See

Features:• Available with a variety of port sizes to easily adapt externally to

your equipment• Available with switch logic per your requirements• Different bottle sizes available• Units can be customized with solenoid valve to automatically drain

Specifications:

Bottle Level Ordering Numbers:

Externally Mounted Level ControlIdeal Switch When Installation of the Level Switch Inside the Tank is Either Impractical or Inaccessible…

Features:• Rugged bronze housing• 316 SS float ideal for water, hydrocarbons• Available with a variety of switch configurations• Available with J/Box and terminal strip attached

Specifications:

Level Control Ordering Numbers:

Page 64: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

64 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

80% Shut-Off Switch forRecovery Refill Cylinders

● Designed specifically for overfill protection ofRefrigerant Recovery Tanks

● Meets rigid UL Requirements for RefrigerantRecovery Equipment

● Switches have been specified to meet thedimensions of the recovery tank manufacturer

● Customize a switch to meet your specific needsincluding multiple floats, various actuation levelsand a variety of wire or connector terminations

Features:• Pressure rating to 400 PSIG (27.6 bar)• Standard for 30# and 50# D.O.T. refrigerant

tanks• Grooved stems keep floats from moving or

falling off• Can be customized for use in other size

cylinders• Available with multiple floats• UL endurance tests performed at 120/60,

240/60, 24/60, 5 VDC, 12 VDC, 24 VDC

CONNECTOR SELECTION DATA

Ground Pin

Master Keyway

Ground Pin is Longer

AMP CONNECTORMATES WITH AMP P/N 206060-1

BRAD HARRISON 3-PINMATES WITH BH-P/N 70303

BRAD HARRISON 2-PINMATES WITH BH-P/N 70023

Page 65: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 65

All Dimensions in Inches (mm)

80% Shut-Off Switch Part Numbering System

3.19

(81

)

1.45

(37

) 5.31

(13

5)

.90 (23)

4 PIN ReceptacleAMP #206153-1

3 PIN ReceptacleBrad Harrison #70212

1-1/16 HEX

3/4-14 NPT

Specifications:

Refrigerant Level Ordering Numbers:

Part “A” “B” Tank Tank PINNumber Dim. Dim. Mfgr. Size Type

V0708-0013.19 5.31 (MAN)*,

30#, 50# Brad 3-Pin(81) (135) (WOR)**

V0808-0013.19 5.31 (MAN)*,

30#, 50# AMP 3-Pin(81) (135) (WOR)**

V1007-0013.19 5.31 (MAN)*,

30#, 50# Brad 3-Pin(81) (135) (WOR)**

V1038-0018.40 10.13 (MAN)*,

250# Brad 3-Pin(213) (257) (WOR)**

V1047-0016.75 8.88 (MAN)*,

100# Brad 3-Pin(172) (226) (WOR)**

V1302-0013.562 5.688

(AMTROL) 26# Brad 3-Pin(90) (144)

V1303-0013.875 6.00

(AMTROL) 50# Brad 3-Pin(98) (152)

V1546-0018.40 10.13 (MAN)*,

250# AMP 3-Pin(213) (257) (WOR)**

V1628-0013.562 5.688

(AMTROL) 26# AMP 3-Pin(90) (144)

V1629-0013.875 6.00

(AMTROL) 50# AMP 3-Pin(98) (152)

V1632-0016.75 8.88 (MAN)*,

100# AMP 3-Pin(172) (226) (WOR)**

Maximum Pressure 400 PSIG Maximum (27.6 bar)Operating Range -40° to 221°F SS Float (-40° to 105°C)

Switch Type SPST, Normally Closed DrySwitch Rating 20VAMounting Plug 3/4" NPT

* MAN = Manchester** WOR = Worthington

Page 66: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Single and Multi-Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9966

Norgren offers two types of custom single and multi-point liquidlevel control designs to meet your specific requirements (see layouton following pages).

Norgren custom level controls allow you to select from variousstandard mounting configurations, materials of construction, floatsizes and materials, along with multiple switch logic and locations.

The Norgren 627 Miniature Series offers mountings from 1/8" NPTto 1" NPT, and lengths up to 48". The standard size multi-pointoffers mountings, from 1/2" NPT to 3" 150# flanges, and lengths to72". Both series could facilitate other mountings to meet yourneeds.

Multi-Point Application ConsiderationsInterface Detection

• Top float detects overall fluid level• Bottom float weighted to sink in lighter fluid and detect presence

of heavier fluid• Ideal for oil-water separators

Hi-Hi Alarm

• Add an additional float, a separate switch, and independentwiring to provide a backup alarm

• Consider utilizing NC Dry switch logic so any open circuit (brokenwire, etc.), will indicate an alarm condition

Dual Level Control with Single Float• Ideal for applications where switch logic allows switches to be

held closed at extreme ends of float travel• Eliminate cost of second float• Allows maximum volume in small tanks

Don’t Let the Catalog Limit YourDesign Requirements• If your application requires a 2" NPT but you

want the 5/16" tubing and 1" float design fromour 627 Series, or any other mountingconfiguration from our standard components,contact Norgren.

Custom Liquid Level ControlsTo Meet Your Specific Requirements

USE THE APPLICATION INQUIRY SHEET ON PAGE 81 FOR QUOTATION AND ORDERING

If your custom liquid level control requirementsare immediate, refer to page 74-75, and order aNorgren KIT and other accessory componentsto customize, build or modify your own multi-level control “IN HOUSE.”

Page 67: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 67Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487

627 Series Miniature Multi-Point Level Switches

● Apply any of our Single Point Detectors to your Multi-Point Application

● Up to 48" overall length

● Up to 5 control points

● UL Recognized File #E129277

● CSA Approved File #90981

Norgren Miniature Multi-Point Level controls provide a convenientmethod of customizing your level control with standard lead timesand costs. Our Miniature Multi-Point offers floats as small as .787diameter for those hard to reach areas with up to 5 actuation levelson a single tank entry. Extend your imagination and allow Norgrento build your custom level control when an off the shelf switch won’t do.

Obtain a copy of Norgren Level Switch Inquiry ApplicationSheet and define the general requirements:

1. Mounting type.2. Stem and float material.3. Float type, noting temperature ranges, pressure limitations and

minimum recommended specific gravity.4. Switch type, considering voltage and load requirements.5. Wiring group, noting that wiring group I can be utilized with up to 5

levels and wiring group ll can be utilized with 3 levels max.6. Number of actuation points and the distance from the bottom of the

mounting plug- Specify L1 through L5.7. LO-Overall length, which is L1 plus the “C” dimension of your float

selection.8. Switch logic, either normally closed or normally open. When

specifying switch logic, please indicate switch condition when tank isdry.

9. Provide a sketch or drawing along with other pertinent information forproper switch selection.

A = minimum distance to highest level B = minimum distance between levels using two floats C = distance from lowest level to end of unit

USE THE APPLICATION INQUIRY SHEET ON PAGE 81 FOR QUOTATION AND ORDERING

L1

L0

L2

L3

L4

L5 A

BC FLOAT NUMBER A DIM. B DIM. C DIM.

V0118-001 3/4" 1-1/2" 1"V0126-002 3/4" 1-1/2" 1"V0289-001 3/4" 1-1/2" 1"V0564-002 1" 2" 1-1/8"V1093-001 3/4" 1-1/2" 1"V1415-001 5/8" 1-9/32" 3/4"V1416-001 3/4" 1-1/2" 1"V2161-001 3/4" 1-1/2" 1"V2304-001 3/4" 1-1/2" 1"

Page 68: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Multi-Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9968

All Dimensions in Inches (mm)

Miniature Multi-Point Design ConsiderationsMounting Styles

WIRINGSPST SWITCHES

Group 1 Group 2Wire #22 AWG #22 AWG

Common Black NoneNO/NC SW Com. NO/NC

L1 Red Red RedL2 Yellow Yellow YellowL3 Blue Blue BlueL4 BrownL5 Orange

SELECTIONCHOICES

TYPE A TYPE B TYPE C TYPE D TYPE E TYPE F

UnitConfiguration

Mounting 1/8" NPT 1/4" NPT 1" NPT 3/4" NPT5/16" 3/8" -24

Tubing THDMaximum 316 SS, Brass up to 48"

Length or PVC up to 24"

V0630-001 V0118-001 Buna N V0126-002 V0564-002 V1093-001 V1415-001 V1416-001316 SS Float (closed cell) Float Polypropylene 304 SS Float Polypro Float Buna Float PBT Float

FLOATCHOICES

Maximum 400 PSI 150 PSI 150 PSI 400 PSI 150 PSI 150 PSI 10 PSIPressure (19 bar) (10.3 bar) (10.3 bar) (27.6 bar) (10.3 bar) (10.3 bar) (.69 bar)Operating -40°F to 300°F -40°F to 225°F -40°F to 150°F -40°F to 300°F -40°F to 150°F -40°F to 225°F -40°F to 225°F

Temperature (-40°C to 149°C) (-40°C to 107°C) (-40°C to 66°C) (-40°C to 149°C) (-40°C to 66°C) (-40°C to 107°C) (-40°C to 107°C)in oil in oil

180°F (82°C) 180°F (82°C)in water in water

Rec. Min..80 .50 .72 .95 .90 .80 .65Liquid SP GR

V2116-001 V2304-001 V1417-001316 SS Float PVC Float Polypro Float

(Hollow)

FLOATCHOICES

Maximum 275 PSI 50 PSI 10 PSIPressure (19 bar) (3.4 bar) (.69 bar)Operating -40°F to 300°F -40°F to 150°F -40°F to 150°F

Temperature (-40°C to 149°C) (-40°C to 66°C) (-40°C to 66°C)Rec. Min.

.70 .80 .55Liquid SP GR

Stem and 316 SS and Brass up toMounting 48" LengthMaterial PVC up to 24" LengthSwitches SPST, 10VA or 50VA

SPDT, OptionalFloat Stops Brass Units -

Beryllium Copper Grip ringsSS Units - ARMCO PH 15-7 MOPVC Units - PVC316 SS Collar Optional

Leads 22 AWG, 24" long

Specifications:1.

06 (

27)

1.10 (28)

1.00

(25

)

1.00 (25)

1.00

(25

)

1.00 (25)

1.50

(38

)

.90 (23)

1.00

(25

)

.75 (19)

.79

(20)

.79 (20)

1.00

(25

)

1.00 (25)

1.00

(25

)

1.00 (25)

1.00

(25

)

1.00 (25)

1.00

(25

)

1.00 (25)

Page 69: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 69Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487

Standard Multi-Point Level Switches

● Customize Norgren's larger single pointdetectors for your multi-point application

● Up to 72" overall length

● Up to 6 control points

● Standard Multi-Point Level controls provide aconvenient method of customizing your levelcontrol with standard lead times and costs

● Standard Multi-Point offers up to 6 actuation levels on a single tank entry

Obtain a copy of Norgren Level Switch Inquiry ApplicationSheet and define the general requirements: (see page 84)

1. Determine mounting type.2. Select the stem and float material.3. Choose float type, noting temperature ranges, pressure limitations,

and minimum recommended specific gravity.4. Select switch type considering voltage and load requirements.5. Specify wiring group.6. Determine the number of actuation points and the distance from the

bottom of the mounting plug. Specify L1 through L6.7. Specify LO-Overall length, which is L1 plus the “C” dimension of

your float selection.8. Determine switch logic, either normally closed or normally open.

When specifying switch logic, please indicate switch condition whentank is dry.

9. Provide a sketch or drawing along with other pertinent informationfor proper switch selection.

L1

L0

L2

L3

L4

L6

L5

WIRINGSPST SWITCHES SPDT SWITCHES

Group 1 Group 2 Group 3 Group 4Wire #22 AWG #22 AWG #22 AWG #22 AWG

Common Black None Black NoneNO/NC SW Com. NO/NC NO NC SW Com NO NC

L1 Red Red Red Red Wh/Red Red Wh/Red Wh/Blk/RedL2 Yellow Yellow Yellow Yellow Wh/Yellow Yellow Wh/Yellow Wh/Blk/YelL3 Blue Blue Blue Blue Wh/Blue Blue Wh/Blue Wh/Blk/BlueL4 Brown Brown Brown Brown Wh/Brown Brown Wh/Brown Wh/Blk/BrnL5 Orange Orange Orange Orange Wh/Orange Orange Wh/Orange Wh/Blk/OrngL6 Gray Gray Gray Gray Wh/Gray Gray Wh/Gray Wh/Blk/Gray

Page 70: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Multi-Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9970

All Dimensions in Inches (mm)

Multi-Point Design ConsiderationsMounting StylesSELECTION

CHOICESTYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6

UnitConfiguration

Mounting 1/2" NPT 1-1/4" NPT 2" NPT3" 150# 1/2" 1-1/2

CS Flange Tubing NPTMax. Length 72" 72" 72" 72" 72" 72"

V0127-001 V0114-001 V0489-001 V2305-001316 SS Float Buna N (closed cell) Float Buna N (closed cell) Float PVC Float

FLOATCHOICES

Maximum 750 PSI 150 PSI 150 PSI 15 PSIPressure (51.7 bar) (10.4 bar) (10.4 bar) (1.03 bar)Operating -40°F to 300°F -40°F to 225°F -40°F to 225°F -40°F to 150°F

Temperature (-40°C to 149°C) (-40°C to 107°C) in oil (-40°C to 107°C) in oil (-40°C to 66°C)180°F (82°C) in water 180°F (82°C) in water

Recommended Min..73 .58 .55 .55Liquid SP GR

Stem and 316 SS and Mounting Material Brass up to 72" Length

Switches SPST, 10VA, 50VA or 100VASPDT, Optional

Float Stops Brass Units - Beryllium Copper Grip ringsSS Units - ARMCO PH 15-7 MO316 SS Collar Optional

Leads 22 AWG, 24" long

FLOAT NUMBER A DIM. B DIM. C DIM.V0127-001 1-1/2" 3" 2"V0114-001 1-1/2" 3" 2"V0489-001 1-1/2" 3" 2"V2305-001 1-1/2" 3" 2"

Specifications:

2.00

(51

)

2.15 (55)

1.75

(44

)

1.19 (30)

1.88

(48

)

1.88 (48)

1.88

(48

)

1.88 (48)

A = minimum distance to highest levelB = minimum distance between levels using two floatsC = distance from lowest level to end of unit

AC

B

USE THE APPLICATION INQUIRY SHEET ON PAGE 81 FOR QUOTATION AND ORDERING

Page 71: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Multi-Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 71

All Dimensions in Inches (mm)

OPTION B: Adjust A Level FittingAvailable for mounting styles types 2, 3, 4 and 6. Special fitting onmounting plug allows for sliding level switch stem up and down,allowing for precise setting of levels.

OPTION C: Bulkhead Compression FittingFor mounting type E miniature and type 5 multi-point level controls.

OTHER OPTIONS:Norgren welcomes the challenge of building your total controlassembly. We can provide custom bottles, assemblies, machining,flanges or other special mounting requirements.

Multi-Point OptionsOPTION A: Junction Boxes with Terminal Strips

Am

ou

nt

of

Ad

j

J/Box comes pre-wired for levels, complete with wiring diagram

Page 72: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Multi-Point Levels

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9972

All Dimensions in Inches (mm)

Temperature and Level ControlCombined for Ease of Installation. Convenient Switch-Wiring and Installation of the Level andTemperature Switch Through One Opening.

Specifications:

Liquid Level Switch Ordering Numbers:

1.50

(38

)

1.75

(45

)

4.25

(10

8)

1.19 (30)

Black

Red

Green

1/4 NPT

5/8 Hex

Maximum Pressure 150 PSI (10.3 bar)Operating Temperature -40° to 225°F (-40 to 107°C) in oil

-40° to 180°F (-40 to 82°C) in waterLead Wires No. 18 AWG, 24" longWetted Materials Beryllium Copper, epoxyThermostat Rating 6A/120V 100VA (Non-inductive)

4A/240V 100VA (Non-inductive)Recommended Minimum Liquid SP GR 0.58

Part Stem Float Switch TemperatureNumber Material Material Rating Switch

V0777-024 Brass Buna N100VA N.C. Open on 160°FSPST* ±20°F, Increasing

V0778-024 Brass Buna N100VA N.O. Close on 160°FSPST* ±20°F, Increasing

V1430-024 Brass Buna N20VA N.C. Open on 160°F

SPDT* ±20°F, Increasing

V1431-024 Brass Buna N20VA N.O. Close on 160°F

SPDT* ±20°F, Increasing

FEATURES:• Simplifies installation for hydraulic power units• Materials of construction ideal for water, hydrocarbons• Available with a variety of switch configurations and temperature

settings

Page 73: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Multi-Point Levels

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 73

All Dimensions in Inches (mm)

Level Controls for 55 Gallon DrumsObtain Valuable Information From the Unused 3/4" Bung Fitting In Your Drum By Installing aNorgren High, Low, or High And Low Level Switch.

Easy to install, the Norgren level switch will provide a signal forhigh level alarm to prevent spills, low level signal to warn operatorit’s time to refill, or high and low alarm combined for total control.High and low level signals can either provide input to alarms or canbe combined with a relay or controller to operate valves or pumps.

Units are available in brass mounting and stem material, and Buna-N float for use in hydrocarbons as well as all stainless steelconstruction for more aggressive media.

32 (

81)

A D

im

.94

(24)

.90 (23)

5/16 (8)

1-1/16 Hex

High and Low Level

HighActuation

Level

LowActuation

Level

LowLevel

HighLevel

32 (

81)

A D

im

C D

im

3/4 NPT

Low Level

ActuationLevel

White

Green

Red

Black

Red

Black

Red

Black

B D

im

.94

(24)

PVC Cable6 ft (183cm)

High Level

ActuationLevel

Part Stem / Float SwitchNumber Material Logic Function

V1295-001 Brass/Buna N.O. Dry High LevelV1295-002 Brass/Buna N.C. Dry Low LevelV1295-003 Brass/Buna N.O./N.C High Level/Low LevelV1295-004 304 SS/304 SS N.O. Dry High LevelV1295-005 304 SS/304 SS N.C. Dry Low LevelV1295-006 304 SS/304 SS N.O./N.C High Level/Low Level

Dim Brass/Buna-N Stainless SteelA 31.00 (79cm) 30 (77cm)B 2.00 (51) 2.63 (67)C 1.25 (32) 1.50 (38)

Switch Rating 150 PSI (10.3 bar)Operating Pressure 100 PSIG Max (6.9 bar)Operating Temperature -40° to 300°F (-40 to 149°C) - SS Version

-40° to 225°F (-40 to 107°C) - Buna (Oil)-40° to 180°F (-40 to 82°C) - Buna (Water)

Minimum Media Buna N Floats .70Liquid SP GR Stainless .80

Specifications

Level Controls For 55 Gal. Drum Ordering Numbers:

Page 74: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

74 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

Off the shelf components allow you to assemble acustom level control in minutes… Start with thebasic Norgren Kit and add up to 4 Norgren Kit Jr. ‘sto build your level control with up to six levels.

● Each starter Norgren Kit contains:1 - Mounting Plug2 - Switch/float assembly2 - 12" extension tubes1 - Tube end fitting3 - Tube unions1 - Tube connector

● Each Norgren Kit Jr. contains:1 - Switch/float assembly1 - Tube union1 - Wire marker label

Norgren Kit

Part Number Material Mounting Temperature PressureV0525-001 Buna N Float 1-1/4" NPT to 180°F in water

150 PSI maxV0525-002 Brass Accessories 2" NPT 0°F to 225°F in oilV0525-003 Buna N Float 1-1/4" NPT to 180°F in water

150 PSI maxV0525-004 316 SS Accessories 2" NPT 0°F to 225°F in oil

V0526-001316 SS Float

2" NPT 0°F to 300°F 500 PSI maxBrass Accessories

V0526-002316 SS Float

2" NPT 0°F to 300°F 500 PSI max316 SS Accessories

Part Number Float Material Stem Material Fitting Material Temperature Pressure (Max)V0527-001 1-3/16" Dia. Buna N Brass Brass to 180°F in water

150 PSIV0527-002 use with 1-1/4" mtg 316 SS 316 SS 0°F to 225°F in oilV0528-001 1-7/8" Dia. Buna N Brass Brass to 180°F in water

150 PSIV0528-002 use with 2" mtg 316 SS 316 SS 0°F to 225°F in oilV0529-001 2" Dia. 316 SS Brass Brass

0°F to 300°F 500 PSIV0529-002 use with 2" mtg 316 SS 316 SS

Norgren Kit

Norgren Kit Jr.

Page 75: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Assembly Options

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 75

All Dimensions in Inches (mm)

Accessory Norgren Kit Components

J/Box W/TerminalPart NumberV0523-001

Mounting Plug Tube ConnectorPart Number Mounting Material A DIMV0533-001 3/8" NPT Brass 1.75V0533-002 3/8" NPT 316 SS 1.75

Bulkhead Connector 1/2" TubePart Number MaterialV0536-001 BrassV0536-002 316 SS

Union Elbow 1/2" TubePart Number MaterialV0537-001 BrassV0537-002 316 SS

Mounting PlugPart Number Mounting Material A DIMV0600-001 1-1/4" NPT Brass 1.25V0600-002 1-1/4" NPT 316 SS 1.25V0601-001 2" NPT Brass 1.75V0601-002 2" NPT 316 SS 1.75

Accessory Norgren Kit Components

1/2" NPT with 6" Tube ExtendedPart Number MaterialV0541-001 BrassV0541-002 316 SS

1-1/4" NPT with 6" Tube ExtendedPart Number MaterialV0542-001 BrassV0542-002 316 SS

2" NPT with 6" Tube ExtendedPart Number MaterialV0543-001 BrassV0543-002 316 SS

1/2" Tube Union for connecting tubesand switch assemblyPart Number MaterialV0534-001 BrassV0534-002 316 SS

1/2" OD TubingPart Number Length MaterialV0538-001 12" BrassV0538-002 12" 316 SSV0539-001 24" BrassV0539-002 24" 316 SSV0540-001 36" BrassV0540-002 36" 316 SS

1/2" Tube End Fitting for sealing and switch assemblyPart Number MaterialV0535-001 BrassV0535-002 316 SS

Float/Switch AssemblyPart Stem Float Lead

Number Material Material A DIM B DIM ColorV0530-001 Brass Buna N 4.00 1.19 RedV0530-002 Brass Buna N 4.00 1.19 BlackV0530-003 316 SS Buna N 4.00 1.19 RedV0530-004 316 SS Buna N 4.00 1.19 BlackV0531-001 Brass Buna N 4.25 1.88 RedV0531-002 Brass Buna N 4.25 1.88 BlackV0531-003 316 SS Buna N 4.25 1.88 RedV0531-004 316 SS Buna N 4.25 1.88 BlackV0532-001 Brass 316 SS 4.45 2.10 RedV0532-002 Brass 316 SS 4.45 2.10 BlackV0532-003 316 SS 316 SS 4.45 2.10 RedV0532-004 316 SS 316 SS 4.45 2.10 Black

A D

im

B Dim

A D

im

B Dim

A D

im

B Dim

For UseWith AnyMounting

Not ForUse With2" NPTMounting

Not ForUse With2" NPTMounting

A

2.58 (66)

1.50

(38

)

1.50 (38)

A

1/2 NPT

2.13 (54)

1.19

(30

)

Page 76: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Norgren Flow Switches

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9976

Norgren flow sensors provide a simple andinexpensive way of monitoring flow of coolant orlubricating oil to bearings and process systems.

Where maximum or minimum flow detection isrequired Norgren offers a choice of models tosuit your needs. We offer our flow switches in avariety of materials which are compatible withmost media.

Flow rates from .1 to 20 GPM and other specialflow rates are available on request; our technicalsupport department will assist you with yourapplications.

Norgren Flow SwitchesFor Automatic Control and Monitoring of Liquid and Gas FlowsThe principle of operation for Norgren Flow switches is simple. A hermetically sealed, magnetically sensitive reed switch ishoused in a brass, stainless steel or plastic body. A magnet equipped piston is calibrated to react to a specific flow rate. Asthe piston is displaced, the reed switch provides a signal. The flow switches detect an increase or decrease in the pre-setflow. Norgren flow switches can be calibrated from .1 GPM to 1.5 GPM and from .5 GPM to 20 GPM in the adjustableseries.

Flow Switch

CalibrationMedia0 = Oil GPM1 = Oil CC2 = H

20 GPM

Standard3 = H

20 CC

4 = Gas CFM

Logic0 = N.O.1 = N.C.2 = SPDT

Wire Length24" STANDARD36"48"72"

Series1 = 10002 = 20003 = 3000 Material

Body Piston0 = SS SS1 = Brass Brass2 = Brass SS3 = Acrylic Delrin®

4 = Delrin® Delrin®

Flow RateSee pages 81-84

Reed Switch0 = 100VA SPST**1 = 20VA SPST**2 = 20VA SPDT**3 = 3VA SPDT**

O-Ring00 = No “O” Ring (Series 1000 only)01 = Buna (Standard)02 = Viton03 = Neoprene®

08 = Teflon®

13 = EthylenePropylene

FS - V 1 2 1 0 1 - 0 0 2 4 - 0150*

Flow Switch Part Numbering System

* Unless otherwise specified, all flow switches are set to activate on increasing flow.** 100 Watt SPST option on Series 2000 & Series 3000 only** 20VA SPST standard on Series 1000 and 2000 only** 20VA SPDT standard on Series 3000 only** 3VA SPDT option on Series 1000 onlyNote: Not all number combinations are valid

With only one moving part mechanical reliability is inherent.Electrically the hermetically sealed reed switch is considered areliable solid state device without the necessary “burn in time”required for true solid state components.

Norgren flow switches are easy to install with standard fittings andcommon threads. Norgren flow switches require no special tools forinstallation.

Page 77: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 77Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487

1000 Series Compact Flow Switch

● Single moving part ensures reliability

● Available in Brass, Stainless Steel, Acrylic orDelrin ®

● Set points from 0.10 GPM to 1.5 GPM

● Suitable for water and oil

SPECIFICATIONS:

WETTED PARTSHousing Brass, Stainless Steel, Acrylic or Delrin®

Piston Brass, Stainless Steel, Teflon® or Delrin®

Epoxy Formulated Resin“O” Ring NA

OPERATING TEMPERATUREBrass -20° F to +300° FStainless Steel -20° F to +300° FAcrylic Up to 165° F

PRESSURE RATING1000 PSIG Brass/SS150 PSIG Acrylic

ACCURACY ±15%

REPEATABILITY 1 %

SWITCH SPST 20VA StandardSPDT 3VA Optional

FLOW SETTING Standard in water, other media on request

• Consult Norgren for more options. Ratings may vary depending upon optional material selected.

®Teflon and Delrin are registered trademarks of E.l. Dupont De Nemours Co.

Brass Flow Setting Stainless SteelPart Number GPM Part Number

FS-V12101-0024-0010 .10 FS-V12001-0024-0010FS-V12101-0024-0025 .25 FS-V12001-0024-0025FS-V12101-0024-0050 .50 FS-V12001-0024-0050FS-V12101-0024-0075 .75 FS-V12001-0024-0075FS-V12101-0024-0100 1.00 FS-V12001-0024-0100FS-V12101-0024-0150 1.50 FS-V12001-0024-0150

.38

(10)

2.75 (70)

1.00 (25)

1/4-18 NPT 1/4-18 NPT

.38

(10)

1.00 (25)

.63 (16)

STANDARD FLOW SWITCHES AVAILABLE:(All are normally open dry.)

USE THE APPLICATION INQUIRY SHEET ON PAGE 82 FOR QUOTATION AND ORDERING

All Dimensions in Inches (mm)

Page 78: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

78 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

● Simple, inexpensive means to monitor process flow

● Ideal as a monitor for coolant or lubricant to bearings

● Detects flow in process systems

● Available in Brass, Stainless Steel, Acrylic or Delrin ®

● Liquid set points from 200 CC/Min to 1.5 GPM

● For gas set points, consult Norgren

SPECIFICATIONS:

WETTED PARTSHousing Brass, Stainless Steel, Acrylic or Delrin®

Piston Brass, Stainless Steel, Teflon®* or Delrin®

Epoxy Formulated Resin“O” Ring Buna, or Fluorocarbon

OPERATING TEMPERATUREBrass -20° F to +300° FStainless Steel -20° F to +300° FAcrylic Up to 165° F

PRESSURE RATINGBrass/SS 1000 PSIGAcrylic 150 PSIGproof pressure 2500 psig**burst pressure 5000 psig**

ACCURACY ±10%

REPEATABILITY 1 %

SWITCH SPST 20VA StandardSPDT 3VA Optional

FLOW SETTING Standard in water, other media on request

• Consult Norgren for more material options. Ratings may vary depending uponmaterial selected.

* Some Options may not be available at time of printing.** Consult Norgren for Acrylic and Delrin® ratings.® Teflon and Delrin are registered trademarks of E.l. Dupont De Nemours Co.

2000 Series Flow Switch

4.13 (105)

2.38 (60)

1.25 (32)

1.00 (25)

.50(13)

.50(13)

.50

(13)

.50(13)

1/2-14 NPT Conduit(Standard)

2x .28 (7)Mounting Holes

1/4-18 NPT

1.75

(44

)

2x .2

5 (6

)

Brass Part Number Flow Setting GPM Stainless Steel Part NumberFS-V22101-0124-0010 .10 FS-V22001-0124-0010FS-V22101-0124-0025 .25 FS-V22001-0124-0025FS-V22101-0124-0050 .50 FS-V22001-0124-0050FS-V22101-0124-0075 .75 FS-V22001-0124-0075FS-V22101-0124-0100 1.00 FS-V22001-0124-0100FS-V22101-0124-0150 1.50 FS-V22001-0124-0150

Flow Rate GPM Pressure Drop PSI.2 1.5.6 2.0

1.0 2.52.0 4.03.0 5.5

PRESSURE DROPSTANDARD FLOW SWITCHES AVAILABLE(All P/N’s are Normally Open Dry)

All Dimensions in Inches (mm)

Page 79: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

7/99 79Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487

3000 Series Adjustable Flow Switch

● Wide Range of Sets Points for Liquid and Gas

● Liquid set points from 0.5 GPM to 20 GPM

● Easy to install and adjust

● Detects minimum or maximum flow

● Available in brass or stainless steel

● For gas set points, consult Norgren

SPECIFICATIONS:WETTED PARTSHousing Brass, Stainless SteelPiston Brass, Stainless SteelEpoxy Formulated Resin“O” Ring Buna, or Fluorocarbon

OPERATING TEMPERATUREBrass -20° F to 300° FStainless Steel -20° F to 300° F

PRESSURE RATING 1000 PSIG

ACCURACY ±10%

SWITCH SPDT 20VA StandardSPST 100VA Optional

FLOW SETTING Standard in water, other media on request

* Consult Norgren for more material options. Ratings may vary depending upon material selected.

Part Number Material Flow Setting GPMFS-V32122-0124-0000 Brass 0.5 GPM to 20 GPMFS-V32022-0124-0000 Stainless Steel 0.5 GPM to 20 GPM

Set Point GPM Flow Rate GPM Pressure Drop PSI2 12 88 14 48 18 8

16 16 2.516 22 6

4.13 (105)

2.56 (65)

.63 (16)

1/2-14 NPT

.63 (16)

1/2-14 NPT

1.25

(32

)

1.25

(32

)

1.25

(32

)

Pressure Drop

Standard Flow Switches Available

USE THE APPLICATION INQUIRY SHEET ON PAGE 82 FOR QUOTATION AND ORDERING

All Dimensions in Inches (mm)

Page 80: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

80 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99

● Economical design for broad range ofapplications

● 2-position, normally off

● Ideal for pool, spa and water industry

● Plastic and stainless steel anti-corrosive construction

● Large, 1/2" and 3/4" ports

SPECIFICATIONS:

MATERIALS (WETTED PARTS)Housing PVCStem PolypropylenePiston PolypropyleneSpring Stainless Steel

OPERATING TEMPERATURE 120° F Max

OPERATING PRESSURE 100 PSIG @ 100°F Max50 PSIG @ 120°F Max

SWITCH SPST, 20VA Pilot Duty

LEAD WIRES 22 AWG 24" long

PORT SIZE 1/2" NPT, 3/4" IPS

ACTUATION ON FLOW INCREASE .25 GPM - 6 GPM ±20%

5000 Series Flow Switch

3.30

(84

)1.

31 (

33)

1.53 (39)

3/4 IPS

3.55

(91

)

1.73 (44)

1/2 NPT

Flow Setting1/2" NPT GPM 3/4" IPS

FS-V5111V-0025 .25 FS-V5100V-0025FS-V5111V-0050 .50 FS-V5100V-0050FS-V5111V-0075 .75 FS-V5100V-0075FS-V5111V-0100 1.00 FS-V5100V-0100FS-V5111V-0200 2.00 FS-V5100V-0200FS-V5111V-0300 3.00 FS-V5100V-0300

Series Body Style Inlet Outlet Material FlowFS-5 1=angle 0=3/4" IPS 0=3/4" IPS V=PVC 0025

1=1/2" NPT 1=1/2" NPT 00500075010002000300

PART NUMBER IDENTIFICATION SYSTEM:(All P/N’s are Normally Open, Dry)

STANDARD FLOW SWITCHES AVAILABLE:(All P/N’s are Normally Open, Dry)

All Dimensions in Inches (mm)

Page 81: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Application Sheets

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 81

Level Switch Inquiry Application Sheet

Name ___________________________________________ Company _______________________________________________

Address__________________________________________ City __________________E-mail________________________

State_____________ Zip ______________________ Telephone_________________________ Fax ________________________

Description of application _____________________________________________________________________________________

_________________________________________________________________________________________________________

Immediate Quantity ____________ Prototype Y ______N ______ Estimated Yearly Quantity ________________________________

Submit Sketch of Tank with Switch Location or Competitor Part Number ________________________________________________

_________________________________________________________________________________________________________

MEDIA INFORMATIONLiquid Media _________________________ Specific Gravity ______________________ Viscosity __________________________

Maximum Temp. ______________________ Minimum Temp. ______________________ Operating Temp. ____________________

Maximum Pressure____________________ Operating Pressure ___________________ Tank Material ______________________

MINIATURE MULTI-POINT LEVEL SWITCHMounting: Top_________________ Bottom_________________ Side _________________

Mounting Type: Type A Type B Type C Type D Type E Type F

1/8" NPT__ 1/4" NPT__ 1" NPT__ 3/4" NPT__ 5/16" Tubing__ 3/8-24__ Other ____________

Stem Material: 316 SS_____ Brass_____ PVC_____ Other_______ Float Part Number _______________

STANDARD MULTI-POINT LEVEL SWITCHMounting: Top_________________ Bottom_________________ Side _________________

Mounting Type: Type 1 Type 2 Type 3 Type 4 Type 5 Type 6

1/2" NPT__ 1-1/4" NPT__ 2" NPT__ 3"150# FL(CS)__ 1/2" Tubing__ 1-1/2 NPT__ Other ____________

Stem Material: 316 SS_____ Brass_____ Other_______ Float Part Number_______________________________

SUCTION TUBE LIQUID LEVEL CONTROLMounting Type: Type E __________ Type F __________ Type G___________ Other ___________________________________

Stem Material: PVC ____________Polypropylene ____________ Other___________ Float Part Number __________________

Overall Length Suction Tube: LS _____________________ LSE (Extended) ___________________________

OTHER SELECTION CRITERIAJunction Box __________ Conduit Adapter __________ Bulkhead Fitting Adapter _____________ Adjust A Level ______________

SWITCH TYPE10VA SPST___________ 50VA SPST__________ 100VA SPST __________ 3VA SPDT ___________ 20VA SPDT ___________

Voltage ___________________ Load Description_____ Wiring Group I _________ Wiring Group II ____________

DIMENSIONAL DATAActuation Level: Inches/MM Indicate N.O. or N.C. with Float in Dry Condition

L6 ________________________ N.O._____________________________ N.C. __________________________

L5 ________________________ N.O._____________________________ N.C. __________________________

L4 ________________________ N.O._____________________________ N.C. __________________________

L3 ________________________ N.O._____________________________ N.C. __________________________

L2 ________________________ N.O._____________________________ N.C. __________________________

L1 ________________________ N.O._____________________________ N.C. __________________________

Length Overall LO ______________

Please Refer to Catalog for Limitation on Numbers of Levels with Each Switch Type and Wiring Group

Application Comments _____________________________________________________________________________________

_________________________________________________________________________________________________________

Copy this page. Fill in the blanks.Fax it to Norgren at (303) 795-9487Call us at (303) 794-2611Date ____/____/____

Page 82: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Application Sheets

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9982

Flow Switch Inquiry Application Sheet

Name ___________________________________________ Company _______________________________________________

Address__________________________________________ City ______________________E-mail _______________________

State_____________ Zip ______________________ Telephone_________________________ Fax ________________________

TO ORDER A FLOW SWITCH BUILT TO YOUR SPECIFICATIONS FILL OUT THE FOLLOWING INFORMATION:

1. Media Being Sensed _____________________________________________________________________________________

2. Specific Gravity__________________________________________________________________________________________

3. Pressure: Operating _________________ & Max ___________________

4. Set point Desired: Increasing ________________________________ or Decreasing __________________________________

5. Viscosity @ Operating Temperature __________________________________________________________________________

6. Temperature: Operating _________________________Max._______________________ & Min. ________________________

7. Material: Brass _________________ Stainless Steel__________________ Other __________________

8. Electrical Contact Requirement:

100 Watt SPST_____________ 20VA SPST ________________ 20VA SPDT ________________ 3VA SPDT ______________

• 100 Watt SPST Option On Series 2000 & Series 3000 Only• 20VA SPST Standard on Series 1000 Only• 20VA Standard on Series 2000 & Series 3000 only• 3VA SPDT option on Series 1000 Only

9. Quantity of Units ___________________________________

10.OEM _____________ or User_________________________

Copy this page. Fill in the blanks.Fax it to Norgren at (303) 795-9487Call us at (303) 794-2611 Date ____/____/____

Page 83: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Application Sheets

7/99 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 83

Valve Inquiry Application Sheet

Name ___________________________________________ Company _______________________________________________

Address__________________________________________ City ____________________E-mail _________________________

State_____________ Zip ______________________ Telephone_________________________ Fax ________________________

Description of application _____________________________________________________________________________________

_________________________________________________________________________________________________________

Valves Per System______________ Manifold ______________________________ (Submit System Schematic)

Immediate Quantity _____________ Prototype Y ______N ______ Estimated Yearly Quantity _______________________________

MEDIA INFORMATION

Air - Y_________ N _____________ Lubricated - Y_________ N _____________ Oxygen Service - Y_________ N _____________

Liquid Media _________________________ Specific Gravity ______________________ Viscosity __________________________

Inlet Pressure ____________________________________ Minimum Temp. ____________________________________________

Downstream Pressure (-) ___________________________ Minimum Temp. ____________________________________________

Maximum Oper. Pressure Diff. (MOPD) (=)________________________Operating Temp. __________________________________

Flow Required Body __________________________ (CV, GPM, SCFM, ETC.) At Operating Pressure ________________________

Flow Required Stop __________________________ (CV, GPM, SCFM, ETC.) At Operating Pressure ________________________

TYPE OF VALVE

Standard Poppet Type Valve - Y_________ N _____________ Isolated Style Valve - Y_________ N _____________ (2WNC Only)

2WNC_________ 2WNO ________ 3WNCFV_________ 3WNCLC ________ 3WNO ________ 3WMP ________ 3WDC _______

Standard Valve Body ____________ Manifold Mount Body ________________ Operator_______ Other _________

Body Material - Brass ___________ 430 SS __________Other____________ (See Page 12 for Body Material)

UL Recognized ________________ CSA Approved _____________________ Food Grade___________________ Other ________

BODY PORTING INFORMATION (SEE PAGES 8 FOR BODY PORTING AVAILABILITY)

Inlets Ports Body - Side__________ Bottom __________ Size ____________ (ie 1/8" NPT, 1/4" NPT, 10-32 UNF)

Outlet Ports Body - Side _________ Bottom __________ Size ____________ (ie 1/8" NPT, 1/4" NPT, 10-32 UNF)

Adapter Porting- Size_____________________________ (ie 1/8" NPT, 1/4" NPT, 10-32 UNF) Other ____________

BODY OPTIONS INFORMATION

Side-Metered Orifice ____________ Side-Metered Common ______________ Bottom-Metered Orifice _______________________

SEAL SELECTION (SEE PAGE 11 FOR SEAL OPTIONS AVAILABLE)

Lower Seal (Buna Standard) _______________________ Upper Seal (Viton Standard) ____________________________________

Seal Selections Special Information_____________________________________________________________________________

_________________________________________________________________________________________________________

COIL SELECTION CRITERIA

Housing Style (See Page 9 For Info) _________________ (ie. Grommet) Bracket - Y_________ N _________

Housing/Plating Special Request _______________________________________________________________________________

_________________________________________________________________________________________________________

Class B________ Class H _______ Molded Coil_______ Tape Wound (Dry) ________________ Wattage Req’d________________

Voltage ________ AC/DC ________ HZ______________ Minimum Voltage_________________ Maximum Voltage _____________

Rectified - Y_________ N ________ Lead Wire (24" STD) ____________ Termination ____________ Spade Style _____________

Continuous Duty_________ Intermittent Duty ___________ Max. Time On _________ Max. Time Off ________ Cycle Rate_______

Will Valve Be in a Moisture Environment _______________ Coil Comments ________

Application Comments _____________________________________________________________________________________

_________________________________________________________________________________________________________

Copy this page. Fill in the blanks.Fax it to Norgren at (303) 795-9487Call us at (303) 794-2611Date ____/____/____

Page 84: Solenoid Valves Section Level Controls & Flow Switches …resources.norgren.com/document_resources/USA/Controls.pdf2 Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/99 Norgren

Warning / Warranty

Littleton, CO USA Phone 303-794-2611 Fax 303-795-9487 7/9984

Warning

These products are intended to use inindustrial compressed air systems only. Do notuse these products where pressures andtemperatures can exceed those listed underSpecifications .

Before using these products with fluids otherthan those specified, for non-industrialapplications, life-support systems, or otherapplications not within published specifications,consult Norgren.

Through misuse, age, or malfunction,components used in fluid power systems canfail in various modes. The system designer iswarned to consider the failure modes of allcomponent parts used in fluid power systemsand to provide adequate safeguards to preventpersonal injury or damage to equipment in theevent of such failure modes. System designersmust provide a warning to end users in thesystem instructional manual if protectionagainst a failure mode cannot be adequatelyprovided.

System designers and end users arecautioned to review specific warnings found ininstruction sheets packed and shipped withthese products. System designers should alsoprovide for all OSHA requirements includingTitle 29 CFR 1910.147 Lockout/Tagout.

It should be recognized that warnings arevalid for any product, regardless ofmanufacturer, and are not restricted to productsmanufactured by Norgren. Norgren’s reputationfor product quality and performance is wellestablished. We feel we have the additionalobligation to provide information or warnings tocustomers to assist them in applying ourproducts in a reasonable and safe manner.

WarrantyLimited Warranty, Disclaimer and Limitationof Remedies

Items sold by Norgren are warranted to befree from defects in materials and workmanshipfor a period of one year from the datemanufacture, provided said items are usedaccording to Norgren’s recommended usagesand within Norgen’s specifications. Norgren’sliability is limited to the repair of, or replacementin kind of, at Norgren’s sole option, any itemsproved defective, provided these items arereturned to Norgren prepaid. To confirm date ofpurchase, invoice date or invoice number mustbe furnished; otherwise, date code on productwill be used to determine eligibility for warrantycoverage. The warranties expressed above arein lieu of and exclusive of all other warranties.

There are no other warranties, expressedor implied, except as stated herein. There areno implied warranties of merchantability orfitness for a particular purpose, which arespecifically disclaimed. Norgren’s liability forbreach of warranty as herein stated in theexclusive remedy, and in no event shallNorgren be liable or responsible forincidental or consequential damages, even ifthe possibility of such incidental orconsequential damages has been madeknown to Norgren.

Norgren reserves the right to discontinuemanufacture of any product or change productmaterials, design, or specifications withoutnotice.