spec 7300

2
PT. LABORINDO SARANA Jl. Arteri Raya Pondok Indah No. 8A JAKARTA. 12240 Telp. : (21) 722-5036, 726-1079 Fax. : (21) 726-1079 Email : [email protected] , [email protected] Applied Biosystems 7300 Real-Time PCR System An integrated platform for the detection and quantification of nucleic acid sequences. Specification: - Dimension: (WxDxH) : 34 x 45 x 49 cm Weight: 34 kg - Thermal cycling system: Peltier-based, 96 well format for 0.2 mL tube. - Supported run: 20 – 100 uL - Temperature accuracy : ± 0.25 C of display temperature - Temperature uniformity : ± 0.50 C, 30 second after clock start - Quantitative PCR run time : < 2 hours - Optical system: Single excitation, four emission filters and CCD camera - Multicomponenting algorithm : Yes - Excitation source: fluorescence lamp - Excitation filter : 1 (one) - Emission filter : 4 (four) - The emission filter are optimized for use with FAM, SYBR-green I, VIC, JOE, TAMRA, and ROX fluorescence dyes - Data collection : Data collected in all 4 filters for all wells regardless of plate setup. Plate set up may be altered after run completes. - Performance: The 7300 system can distinguish between sample containing 5,000 and 10,000 template copies with a confidence level of 99.7% 9 logs of linear dynamic range - Software: SDS Software (for data collection, data analysis, instrument control) Primer express (for primer and probe design Includes : - Dell Tower Computer

Upload: andry-wiguna

Post on 14-Apr-2016

222 views

Category:

Documents


0 download

DESCRIPTION

7300

TRANSCRIPT

Page 1: Spec 7300

PT. LABORINDO SARANAJl. Arteri Raya Pondok Indah No. 8AJAKARTA. 12240Telp. : (21) 722-5036, 726-1079Fax. : (21) 726-1079Email : [email protected], [email protected]

Applied Biosystems 7300 Real-Time PCR SystemAn integrated platform for the detection and quantification of nucleic acid sequences.

Specification:- Dimension:

(WxDxH) : 34 x 45 x 49 cm

Weight: 34 kg

- Thermal cycling system: Peltier-based, 96 well format for 0.2 mL tube.

- Supported run: 20 – 100 uL

- Temperature accuracy : ± 0.25 C of display temperature

- Temperature uniformity : ± 0.50 C, 30 second after clock start

- Quantitative PCR run time : < 2 hours

- Optical system: Single excitation, four emission filters and CCD camera

- Multicomponenting algorithm : Yes

- Excitation source: fluorescence lamp

- Excitation filter : 1 (one)

- Emission filter : 4 (four)

- The emission filter are optimized for use with FAM, SYBR-green I, VIC, JOE, TAMRA, and ROX fluorescence dyes

- Data collection : Data collected in all 4 filters for all wells regardless of plate setup. Plate set up may be altered after run completes.

- Performance: The 7300 system can distinguish between sample containing 5,000 and 10,000 template

copies with a confidence level of 99.7% 9 logs of linear dynamic range

- Software: SDS Software (for data collection, data analysis, instrument control) Primer express (for primer and probe design

Includes :- Dell Tower Computer- UPS- Starting reagents and consumables :

TaqMan Universal PCR mastermix

SYBR Green Universal PCR Mastermix

Microplate

Optical adhesive cover

- Installation and user training on site

Page 2: Spec 7300

PT. LABORINDO SARANAJl. Arteri Raya Pondok Indah No. 8AJAKARTA. 12240Telp. : (21) 722-5036, 726-1079Fax. : (21) 726-1079Email : [email protected], [email protected]