KONČAR – Electrical Engineering Institute Inc.

Department for rotating machines

Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385 1 3666 377 Web: www.koncarmonitoring.com Email: [email protected]

Architecture:

• Data acquisition unit with the real time controller and 6,7” touch display

Inputs:

• Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V)

Communication:

• Ethernet 10/100

Power supply:

• DC: 80 V to 370 V • AC: 85 to 264 V , frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground)

Temperature range:

• Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions:

• Suitcase – typical dimensions WHD: 430x320x180

• Cabinet – Typical dimensions WHD: 400x400x300

Data visualization:

• 6,7 ” touch display for local HMI • Web browser for local and remote access

Data logging:

• Database for long-term data archival

Standards compliance:

• EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1)

• Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29)

SRI specification

Page 2: SRI specification...KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax:

SRI instrument measures mechanical imperfections such as out-of-roundness and non-concentricity with respect to the bearing surface, with relative displacement probes positioned over track area that is adjacent to each bearing. The reading which results from these imperfections, usually known as runout, must be reduced if it exceeds the recommended value.

www.koncarmonitoring.com

SRI

2 3

SLOW-ROLL RUNOUT INSTRUMENT

1

Ethernet

AGAP Features

• On-line analysis • Automatic report generation • Data export to other systems • Database for long-term data archival • Detailed of-line measurement data analysis • Comparisons to earlier recorded data • Reduces the potential damage costs • Better asset management

2

1

1

1 1

1

1 1

SENSORS: 1 – relative displacement sensors 2 – key phasor

SRI

Web HMI (detailed data analysis )

Report

Page 3: SRI specification...KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax:

KONČAR – Electrical Engineering Institute Inc.

Department for rotating machines

Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385 1 3666 377 Web: www.koncarmonitoring.com Email: [email protected]

Architecture:

• Data acquisition unit with the real time controller and 6,7” touch display

Inputs:

• Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V)

Communication:

• Ethernet 10/100

Power supply:

• DC: 80 V to 370 V • AC: 85 to 264 V , frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground)

Temperature range:

• Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions:

• Suitcase – typical dimensions WHD: 430x320x180

• Cabinet – Typical dimensions WHD: 400x400x300

Data visualization:

• 6,7 ” touch display for local HMI • Web browser for local and remote access

Data logging:

• Database for long-term data archival

Standards compliance:

• EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1)

• Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29)

SRI specification