steel joist floor systems best practices - microsoft · pdf filesteel joist floor systems best...
TRANSCRIPT
Copyright © 2016 Steel Joist Institute. All Rights Reserved.
Steel Joist Floor Systems Best Practices
A P R I L 2 0 , 2 0 1 6
Presented by: Michael A. West, P.E., F.ASCE
David Samuelson, P.E.
Learning Objectives • Identify Codes and Standards providing requirements and guidance for
selecting joists and Joist Girders for steel joist supported floor systems.
• Review of where standard joists, constant shear joists (KCS joists), “Special Joists” for supporting non-uniform and concentrated loads, or CJ-Series Composite Joists may be advantageous.
• Discuss SJI publications that are available to assist the Structural Engineer to design steel joist floor systems for serviceability, for selecting appropriate UL fire resistance ratings, and for adapting joists for future building uses.
2
Learning Objectives • Demonstrate SJI’s future Floor Bay Analysis tool showing how this tool can
optimize the layout and select optimal depths for non-composite K-Series, LH-Series, and DLH–Series joists and Joist Girders as well as CJ-Series composite joists.
• Learn how the recent incorporation of SJI’s Virtual Joist Girder tables within RAM Structural System, RISA, and SCIA Engineer facilitates the selection of Joist Girders within lateral load resisting frames.
• Learn how SJI’s new Virtual Joist tables can yield a reasonable approximate joist effective moment of inertia and weight for joists with non-uniform loading, concentrated loads of varying magnitude, and / or externally applied local moments.
3
Copyright © 2016 Steel Joist Institute. All Rights Reserved.
Successfully Using Steel Joists in Floor Construction
A TOOL KIT
Presented by Michael A. West, P.E., F.ASCE
Outline
Loads and Resistance Non-composite vs. Composite v. KCS-Series Joists Deck Lateral Load Resisting Frames w/ joists and JG
Serviceability Deflection Vibration
Fire Resistance Accommodating M-E-P Adaptability – modifying joists & Joist Girders
5
Loads IBC Table 1607.1
6
TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE , LO AND
MINIMUM CONCENTRATED LOADS LIVE LOADS
OCCUPANCY OR USE UNIFORM (psf) CONCENTRATED (pounds)
22. Office buildings
Corridors above first floor 80 2,000
Files and computer rooms Based on occupancy Based on occupancy
Lobbies and 1st flr. corridors 100 2,000
Offices 50 2,000
27. Schools
Classrooms 40 1,000
Corridors above first floor 80 1,000
First floor corridors 100 1,000
IBC 1607.4 Concentrated LL
Distributed over an area 2 ½ feet by 2 ½ feet:
2000/(2.5)2 = 320 psf 1000/(2.5)2 = 160 psf
7
43RD Edition Catalog
Standard Specifications, 43rd Edition
K-Series LH-Series DLH-Series Joist Girders
Load and Weight Tables SJI Code of Standard Practice
8
Composite Steel Joist Catalog
Standard Specifications for Composite Steel Joists, First Edition CJ-Series How to specify and more
9
Composite Steel Joist Catalog
Standard Specifications Responsibility of the Specifying
Professional Design Guides Examples Code of Standard Practice for Composite
Steel Joists -Composite Joist Floor Design Parameters
Check List
10
Designating CJ-Series Joists
30 is the joist depth 2188 is the “Total Factored Composite
Design Load” 1168 is the “Total Factored Composite
Live Load” 420 is the “Total Factored Composite
Dead Load”
11
30CJ 2188/1168/420
Steel Decks in Floor Construction
Form decks vs. Composite decks Profiles (and thicknesses) (Gage numbers)
1” Form Deck (0.017”-0.04”) (26-20) 1-1/2” Form Deck (0.023”-0.04”) (24-20) 2” Form Deck (0.023”-0.04”) (24-20) 1-1/2” Composite Deck (0.03”-0.06”) (22-16) 1-1/2” Comp. Deck Inverted (0.03”-0.06”) (″) 2” Composite Deck (0.03”-0.06”) (22-16) 3” Composite Deck (0.03”-0.06”) (22-16) 12
Framing Layout – A Function of
Loads and required resistance Slab thickness &
deck profile & joist spacing &
joist depth & structure depth &
story height The combinations are nearly infinite! Stay tuned for SJI’s Floor Bay Analysis Tools
13
AISC Design Guide No. 3
Serviceability Design Considerations for Steel Buildings
14
IBC – 2015 & AISC Design Guide 3
IBC Table 1604.3
AISC Design Guide 3 Non-composite, “across the bay” Span/360, max. 1 inch for dead load Span/360, max. 1 inch for 50% live load
15
Construction Live Snow/Wind Dead + Live*
Floor Members L / 360 - L / 240
* For steel structural members, the dead load shall be taken as zero.
SJI Technical Digest No. 5
Vibration of Steel Joist – Concrete Slab Floors
16
Acceptance Criteria – Walking (3-9 Hz)
17
Tolerance acceleration ratio
Peak acceleration ratio
Vibration – Walking Excitation
18
Activity Recommended Live Load (psf)
Walking – Paper Office 11
Walking – Electronic Office 6 – 8
Walking – Residence 6
Walking – Assembly Area 0
Walking – Shopping Mall 0
Dancing 12.5
Lively Concert 31
Sports Event 31
Rhythmic Activities 4.2
Table 1.2 - TD 5 (DG 11) Recommended Live Loads for Vibration Analysis
(For use in determining natural frequency)
Damping, β
19
Vibration – Walking Excitation
20
Table 3.1 Recommended Tolerance Accelerating
Limits
Occupancy Tolerance Acceleration Limit (ao/g)x100%
Offices, Residences 0.5 – 0.55% Assembly Areas, Worship,
Schools 0.5 – 0.55%
Shopping Malls 1.5%
AISC Design Guide No. 11
Floor Vibrations – Due to Human Activity
21
Fire-proofed vs. Unprotected
A required class of construction is a function of
Occupancy, and Height and area
Fire rated construction can be achieved in joist/Joist Girder construction, but it’s costly and makes M-E-P installation and maintenance more difficult
22
Construction Classification
IBC, Chapter 6 and Table 601 Type II, B – Noncombustible materials Type II, B – Fire-Resistance Ratings
Primary structural frame – 0 (zero) Floor construction and associated secondary
members – 0 (zero)
23
Height and Area Limits
IBC, Chapter 5 and Table 503 for Type II, B Maximum height – 55-feet Assembly (A-1 through A-5)
Stories – 2 (unlimited for A-5) Area – 8,500 to 9,500 sq.ft. (unlimited for A-5),
per story Business (B)
Stories – 3 Area – 23,000 sq.ft.
24
Height and Area Limits, cont.
IBC, Chapter 5 and Table 503 for Type II, B Educational (E)
Stories – 2 Area – 14,500 sq.ft.
Factory (F-1 and F-2) Stories – 2 for F-1 and 3 for F-2 Area – 15,500 sq.ft. for F-1 and
23,000 sq.ft. for F-2
25
Height and Area Limits, cont.
IBC, Chapter 5 and Table 503 for Type II, B Mercantile (M)
Stories – 2 Area – 12,500 sq.ft.
Residential (R-1 and R-2), not incl. R-3 and R-4
Stories – 4 for R-1 and R-2 Area – 16,000 sq.ft. for R-1 and R-2
26
SJI Technical Digest No. 10
Design of Fire-Resistive Assemblies with Steel Joists Floors and Roofs
Membrane and Spray-Applied Fire Resistive Materials
27
SJI Technical Digest No. 10
28
Appendix Tables for Floors and Roofs w/ UL Design Numbers
Group D – Concrete and Steel Floor Units Group G – Concrete and Steel Joists
UL Design G501
29
AISC Design Guide No. 19
Fire Resistance of Structural Steel Framing
30
Accommodation of M-E-P Under the framing:
Simpler Probably increases story height Need to consider structure depth vs. story ht.
Through the framing: Requires greater attention to structure/M-E-P co-ordination, including turning the corner May limit duct sizes Joists as deep as possible X-bridging provisions (TD 2)
And a hybrid (of course) 31
SJI Technical Digest No. 12
Evaluation and Modification of Open Web Steel Joists and Joist Girders
32
Modification of Joists and Joist Girders
Modify to increase load capacity Modify for new concentrated loads Modify to shorten at headered openings
33
SJI Technical Digest No. 11
Design of Lateral Load Resisting Frames Using Steel Joists and Joist Girders
34
In Conclusion - Consider
Loads and Resistance Serviceability
Deflection Vibration
Fire Resistance Accommodation of M-E-P Adaptability And using the SJI Floor Bay Analysis Tools
35
Copyright © 2016 Steel Joist Institute. All Rights Reserved.
SJI Floor Design Tools
Presented by David Samuelson, P.E.
SJI Floor Design Tools
SJI Floor Bay Analysis Tool SJI Virtual Joist Tables SJI Virtual Joist Girder Tables
37
SJI Floor Bay Analysis Tool
38
Joist Spans
39
Joist Girder Spans
40
Noncomposite or Composite
41
Standard K, LH, & DLH or Load / Load Joist
42
Loads, Deck & Concrete Criteria
43
Steel Deck Options
44
2 – 18 Gage 3 – 22 Gage 3 – 20 Gage 3 – 18 Gage 9/16 Form – 28 Gage 9/16 Form – 26 Gage 9/16 Form – 24 Gage 9/16 Form – 22 Gage 1 Form – 26 Gage 1 Form – 24 Gage 1 Form – 22 Gage 1 Form – 20 Gage 1.5 Form – 22 Gage 1.5 Form – 20 Gage 1.5 Form – 18 Gage
Min. & Max. Joist / Joist Girder Depths, Deflection Criteria and Minimize X-Bridging
45
Deck, Concrete & Joist Summary
46
Bridging & Joist Girder Summary
47
Estimated and Actual Joist / Joist Girder Weights
48
User Defined Cost Data
49
Final Design
50
Design Run Comparisons
51
Run Data copied to Run Comparison
52
Composite Joist Comparison
53
Joist Depth must be entered for Composite Joists
54
Composite Joist Design
55
Copy Composite Joist Design to Run Comparison Table
56
Total Cost, $/sf for Noncomposite vs. Composite Joist Design
57
Future Release of SJI Floor Bay Analysis Tool – May, 2016
https://steeljoist.org/product-category/design-tools/
58
Classic Roof and Floor Framing Programs
“Standard” SJI joists only managed as simple-span infill joists supporting vertical gravity loads.
59
SJI’s Virtual Joist and Virtual Joist Girder Load Tables
Standard programs such as RAM Structural System, RISAFLOOR, SCIA, etc. do an excellent job of selecting “Standard” SJI joists.
60
Standard Joists Selected Based on Span and Uniform Loading
61
RAM Structural System Partial Framing Plan
Classic Roof and Floor Framing Programs
“Standard” joist designations and definition do not address concentrated loads, end moments, negative moments or axial loads.
62
Steel Joist \ Joist Girder Stiffness not Included in Structural Model
63
Quote from STAAD-PRO Technical Reference Manual
What are Virtual Joist / Virtual Joist Girder Tables
64
Virtual Joists and Virtual Joist Girders are a set of pseudo section properties based on commonly available joist chord pairs. The major axis moment of inertia (Ixx) is based directly on a pair of double angle joist chords and pre-adjusted for approximate deflection contribution from web strain. Allows joists and Joist Girders to be checked for flexure, shear, axial, and combined forces by treating them as doubly symmetric I –shaped beam sections. Can be inserted into stiffness based structural analysis programs such as RAM, RISAFLOOR, SCIA, etc.
What are Virtual Joist / Virtual Joist Girder Tables
65
Virtual joist and Virtual Joist Girder tables allow joist member stiffness to be accounted for in the overall building model. Once the building model is completed, standard SJI joist and Joist Girder designations are called out on the plans.
SDSM&T Comparison Study of VJ and VJG Tables
66
Joist Girder Frame Model
67
24 @ 5'-0" = 120'-0"
23'-6"
FRAME MODEL @ GRID LINE B & E
P P P
WIN
D =
100
0 pl
f
1 2 3 4
5 6 7
WIN
D =
100
0 pl
fG3 G3G4P : DL = 2.4 kips LL = 4.0 kips TL = 6.4 kips WL = 7.0 kips
VJ / VJG Tables permit easy determination of required effective Ixx for joist /Joist Girders in the structural model.
Virtual Joist Girder
68
Reporting Loads
Note: Please contact the Project Structural Engineer of Record if the final effective Joist Girder Moment of Inertia (Ixx) varies from the tabulated target value by more than 10%.
Virtual Joist / Virtual Joist Girders
69
SCIA Screen Shot
Joist and Girder Designations displayed in VJG Format
70
RAM Steel Partial Framing Plan
RISAFLOOR – Draw Virtual Joist Girders
71
Virtual Joist Girder
72
RISAFLOOR- Draw Virtual Joists
73
Virtual Joists
74
RISAFLOOR
75
RISAFLOOR Weight Takeoff
76
RISAFLOOR – VJ / VJG Moment of Inertia
77
RISAFLOOR – VJ / VJG Moment of Inertia
78
Min Izz effective = 134 in4
SCIA Virtual Joist Designation
79
SCIA Special Joist Designation
80
SCIA VJG Designation
81
How should a Virtual Joist or Virtual Joist Girder be Specified on the Structural Drawings?
It is important to specify all joists and Joist Girders using conventional SJI designation nomenclature.
82
185/100 Uniform Load (PLF)
50’ Span
ASD 28K7 Joist
Standard Joist Designation ASD 28 K 7
Allowable Strength Design
Joist Depth in inches
Joist Series
Chord Size
How should a Virtual Joist or Virtual Joist Girder be Specified on the Structural Drawings?
83
Joist Space 11.9K 11.9K 11.9K 11.9K 11.9K 11.9K 11.9K
Joist Girder Span (C.L. of column to C.L. of column)
Standard Joist Girder Designation
ASD 44G 8N 11.9K Allowable Strength Design
Depth of Girder in inches
Number of Joist Spaces
Load in Kips at Each Panel Point
SCIA – Standard SJI Joist Designations Shown on Structure Labels in Structure
84
Conclusions SJI’s Virtual Joists permit the determination of joist weight and effective Ixx for complex load cases. Recent incorporation of SJI’s Virtual Joist Girder Tables within RAM Structural System, RISAFLOOR, and SCIA Engineer allows one to readily determine Joist Girder weights and effective moments of inertia in a lateral load resisting frame. Utilizing SJI’s Virtual Joist / Virtual Joist Girder Tables, one can now determine the estimated weight and cost for complex loaded “Special” joists and non-symmetrically loaded Joist Girders.
85
Conclusions
SJI’s Floor Bay Analysis Tool facilitates the calculation of estimated total floor costs for K, LH, DLH and CJ-Series composite joists. Current codes, specifications, design guides, and design tools make the design of joists and Joist Girders more efficient than ever before.
86
Future SJI Webinars on VJ / VJG Tables
May 18, 2016 RAM Structural System June 1, 2016 SCIA Engineer June 15, 2016 RISAFLOOR
87
https://steeljoist.org/product-category/webinars/
Copyright © 2016 Steel Joist Institute. All Rights Reserved.
THANK YOU
88