stepless shower base detail - · pdf filecond unit opening at 2180h. robe robe ... class 1...
TRANSCRIPT
GSPublisherVersion 0.0.100.100
Callen Bray BA(Arch), BArch.(Hons) (Deakin)
Building Design & DraftingResidential - Commercial - Industrial
ABN: 38 040 205 161Phone: 0419 441 186
Email: [email protected] Building Practitioner: DP-AD 36967
Sheet No: 1Issue: 4/04/17Rev: 1
7.8m x 12.5m2 Bedroom
Proposed DPU,At: No. 515 Beenak Road, Seville, VIC, 3139For: Margaretha Derksen
DP
DP
RA
S/B
I/WE .............................................................................................................................
ACKNOWLEDGE THAT THESE PLANS ARE A TRUE AND ACCURATEREFLECTION OF OUR REQUIREMENTS AND AGREE THAT THESEPLANS ARE THE PLANS REFFERED TO IN THE MAJOR DOMESTICBUILDING CONTRACT BETWEEN "BETNALE PTY LTD"(TRADING AS SUPERIOR GRANNY FLATS) AND MYSELF/OURSELVESAND AUTHORISE THEIR USE FOR NEXT STAGE PURPOSES. I/WE AM/AREFULLY AWARE, IF ANY FURTHER CHANGES ARE TO BE MADE ON THESEPLANS WILL INCUR A VARIATION FEE.
SIGNED: .............................................................................. DATE: ............................
SIGNED: .............................................................................. DATE: ............................
PREF
L
870
870
A18
00
-151
0 (D
G)
A90
0-1
210
(DG
)
870
870
870
1500
2350A
210
0-2
110
A2000-610
(DG) A2000-1810(DG) A2000-6
10
(DG)
870
T2110-915 A2100-2110
FLOOR AREASGRD. FL. 89.0m²
SUB TOTAL 89.0m²
VER./POR. 32.0m²
TOTAL 121.0m²
WM
INST.LPGHWS
UBOCT
GAS
POSITIONGAS CYLINDERS
DP
FLOOR COVERING AREAS
CARPET
TILES
DP
LdryBathKit
Porch
DN
A600-610(DG) (OBS)
A900-910(DG)
A2000-1210 (DG) A600-910(DG) (OBS)
700
620
90 5,000 9059090 1,170
901,035 90 1,600 90 2,475 90
12,500
90 2,510 90 2,400 90 1,850 90
451,8
00
7,8
00
451,2
00
90510
903,
405
904,
125
90
901,0
3590
3,0
00
90
4512
51,6
7590
4,53
090
1,035
901,8
7590
902,
050
460
9040
0 90
907,
620
90
903,
830
903,
700
9030
0
950
451,8
00
3,92
03,
88
0
4512
51,6
7545
125 1,1
4512
51,1
7510
01,2
05
903,
700
90
8,900
451,400
45
45 1001,200
10045
45 2,555 90 2,105 600 2,050 600 675 90 3,600 90 300
2,195 600 2,050 600 4,455
45 125 1,923 125 1,923 125 1,923 125 1,923 125 1,923 125 1,923125
45
60
0
90 6,030 90
1,10
0
1,80
0
535200
120120
120
955
1,00
0
3,270 1,510 435 385
850
100 1,100 100
D
C
B
A
53.8 m2
28.1 m2
A/C
CON
DUN
IT
OPENINGAT 2180H.
ROBE
ROBE
RAMPED WALKWAY ATMAX. 1 IN 14 GRADIENT& MIN. 1m CLEARBETWEEN H/RAILS
WA
LL MOUNT
INVERTER
BULKHEADAT 2180H.
OUTSIDE
SPLAY
1200x900 STEPLESSSHOWER. CHECK IN15mm ALL SIDES
POSTS
VERGE
EAVE
S
POSTS POSTS POSTS POSTS POSTS
POS
TS
POS
TSPO
STS
POS
TS
S/B HATCHING INDICATES
LOAD BEARING WALL
RAMP
RAMP
POS
TS
PORC
H T
OPO
STS
PORCH TO POSTS
190x45 F7 H3TREATED PINEBEAMS OVERPORCH (U.N.O)
SEALED PVC DP'S FORCHARGED RAINWATERHARVESTING SYSTEM
2/190x45 F7 H3T/PINE BEAM OVER
PORCH TOPOSTS
120
0W
.
MERBAUTIMBER
DECKINGWITH MAX.
3mm GAPS
X
X
DPDP
Meals
Lounge
Bed 2
Bed 1
Wc
Entry
SEAT
2/240x45 F7LINTEL OVER
2025
75 15
40
WALL TILES
CHECK OUT
WATERPROOFSILICONE SEALANTCH
ECKO
UT
Stepless ShowerBase Detail
FLOO
RING
SET
-DOW
N
SET DOWN FLOORING HERE 20mmFOR STEPLESS SHOWER BASE.CHECK TOP OF JOISTS TO SUIT
900x1200 GLASSTONESTEPLESS SHOWER BASE
FLOOR TILES
WATERPROOFSILICONE SEALANT
SH
OWER
BA
SE
10mm WATERRESISTANTP/BOARDSUBSTRATE
Scale 1:10
25
Scale 1:2
FLOOR TILES
CONTINUOUS IN-SITU WATERPROOFMEMBRANE TO ENTIRE BATHROOMFLOOR OVER P/BOARD FLOORING(WHEN NO F.C UNDERLAY IS USED)
SKIRTING TILES
MIN
IMUM
W/P
ROOF
ING
ABO
VE F
INIS
HED
FLOO
R LE
VEL
BOND BREAKER:- FLEXIBLE SEALANT FILLET OR- 6mm BACKING ROD WITH TAPE
Wet Area Floors(Ceramic Tiles)Wall-Floor Junction
CONTINUOUS. W/PROOFSILICONE SEALANT3-5mm TO SUIT SPACERS
19mm P/BOARDFLOORING
WATER RESISTANTP/BOARD LINING
2,700
2,100
300
35x70 MGP10BATTENS &900 CTS
REFLECTIVE FOILINSULATION UNDERROOF SHEETS
STRAMIT COLORBONDCORRUGATEDROOFING AT 15°
TOP PLATE
EAVESFACE FRAME
TO BACKFASCIA
Scale 1:20
Typical EaveWall-Roof Junction
PROFILED COLORBONDGUTTERS
200mm F.C. PLANKINGWITH PAINTED FINISH
ROOF TRUSSES TOMANUFACT. DESIGN& DETAILS AT 900 CTS.
TRIMOULD
WINDOW HEADS
PLASTEREDCEILING WITHCORNICE
10mm PLASTERBOARDWALL CLADDING
COLORBONDPROFILED FASCIA
67mm MDFARCHITRAVES
PREF
LWM
INST.LPGHWS
UBOCT
GAS
POSITIONGAS CYLINDERS
20 A
MP
ISO
W/S
WIT
CH
MAX 45W
MAX 45WMAX 45W
MAX 45W
MAX 45W
MAX 45W
MAX 43W
MAX 43W MAX 43W
A/C
CON
DUN
IT
RANGEHOOD EXT. FANDUCTED THROUGH WALL
BATHROOMEXT. FAN DUCTEDTHROUGH EAVE
S/B
MAX 45W
MAX45W
MAX45W
MAX45W
4512
51,6
7512
51,1
9012
51,1
7510
01,2
05
100
1,790
100
1,790
100
451,8
00
451,3
121,3
07
1,257
451,8
951,8
9545
451251,9231251,9231251,9231251,9231251,9231251,92312545
1001,4501001,4501001,4501001,4501001,4501001,4501001,4501001,450100
2,195 600 125 1,800 125 600 4,455
45 100 2,455 100 925100
925 100
600 2,050 600
4512
51,0
7512
547
5
4512
51,7
2012
51,1
4512
51,1
7510
01,2
05
100
1,790
100
1,790
100
4512
51,0
756
00
NOTE: DOUBLEJOISTS UNDEREND WALLS
DECK 2/140x45 F7 H3 TREATED PINEBEARERS: MAX. SINGLE SPAN 2,600mm
DECK 140x45 F7 H3 TREATED PINEJOISTS: MAX. SINGLE SPAN 2,300mm AT 450 CTS
BEA
RERS
POS
TS
POSTSPOSTSPOSTSPOSTSPOSTSPOSTS
STUMPS
STU
MPS
STU
MPS
STU
MPS
STU
MPS
STU
MPS
STUMPS
STUMPS
POS
TS
STU
MPS
STU
MPS
POS
TSPO
STS
POS
TSPO
STS
BEA
RERS
BEA
RERS
BEA
RERS
BEA
RERS
BEA
RERS
STUMPSSTUMPSSTUMPSSTUMPSSTUMPSSTUMPSSTUMPS
STUMPS STUMPS
NOTE: 2/90x45 LVL15 (F17) BEARERSUNDER LOAD-BEARING WALL ONLY
NOTE: 2/90x45 LVL15 (F17) BEARERSUNDER LOAD-BEARING WALL ONLY
NOTE: 125x125F7 CYPRESS STUMPSTO THIS AREA
650
1085
500
-
SINK6
7
9
8
DW
TROUGH
WM
ABOVE FFL No.
600
10 FR WASTE
WATER PIPE LOCATIONS
1000/1800
600
BIDET
BATH
SHOWER4
3
2
1
BASIN5
No.
TOILET
ITEM ITEM
FRAME OFFSETS: SHOWER ROSE= 430 CL, SHOWER TAPS= 250 CL, SOAP HOLDER= 550 CL
600/1275
250
250
TOWEL RING
ITEM HEIGHT ABOVE FFL
1000 NOMINAL
820
1000/1600
820
SHOWER SOAP HOLDER
TOWEL RAIL
PAPER HOLDER
FITTING LOCATIONS
NOTES: - DIMENSIONS TAKEN FROM FRAME
INTERNAL ELEVATIONS SPECIFICATION
ABOVE FFL
- WET AREA SKIRTING BOARDS: SOLID TIMBER 67mm
- SPLASHBACK TILES: 200x200
- POWERPOINT LOCATION
- CEILING LIGHT OUTLET (240v)
- PHONE POINT AT 200/1000
- EXHAUST FAN (SELF SEALING)
- T.V. POINT AT 200
- SMOKE DETECTOR (DIRECT WIRED)
- INTERNAL SWITCH BOARD
ELECTRICAL LEGEND
1350 F.F.L
1275 F.F.L
1400 F.F.L
2000 F.F.L
IN ROOF
HEIGHTSPP DPP
750 F.F.L
1200 F.F.L
DPP
200 F.F.L
350 F.F.L
970 F.F.L
1000F.F.L
HEIGHT
1000 F.G.L
SPP
Sub-Floor PlanScale 1:100
Electrical PlanScale 1:100
Floor PlanScale 1:100
GENERAL NOTES
- ENERGY EFFICIENCY (WALL, FLOOR, ROOF INSULATION & GLAZING) IN ACCORDANCE WITH PART 3.12 OF THE NCC 2016: REFER TO ENERGY EFFICIENCY NOTES & GLAZING CALCULATIONS FOR DETAILS.
- WET AREAS IN ACCORDANCE WITH PART 3.8.1 OF THE NCC 2016 FOR WATERPROOFING & WATER RESISTANCE.
- STEPS: TREAD- 250mm MIN, RISER- 190mm MAX.
- BALUSTRADE : - AT STEPS- 865mm (MIN) HIGH - AT LANDING- 1000mm (MIN) HIGH
- WHERE REQUIRED, HORIZONTAL & VERT. GAPS IN BALUSTRADES MUST BE LESS THAN 125mm IN ACCORDANCE WITH NCC 2016 PART 3.9.2
- WRITTEN DIMENSIONS WILL TAKE PRECEDENCE OVER SCALE.
- UNLESS OTHERWISE INDICATED ALL WALL DIMENSIONS ARE: - EXTERNAL 90mm STUD - INTERNAL 90mm STUD
- WC / BATHROOM DOOR TO BE REMOVABLE WHERE REQUIRED AND FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH NCC 2016 PART 3.8.3.3
- ALL GLAZING TO COMPLY WITH PART 3.6 OF THE NCC 2016 & AS 1288
- MECHANICAL VENTILATION TO OUTSIDE AIR PROVIDED WHERE REQUIRED AND IN ACCORDANCE WITH NCC 2016 P.2.4.5 / 3.8.5
- ROOF TRUSSES (WHERE USED) TO HAVE A MAXIMUM SPACING OF 900mm
- WINDOW GLAZING CODES: - (OBS) OBSCURE GLASS - (TLS) TRANSLUCENT GLASS - (DG) DOUBLE GLAZED
- ROOF ACCESS (WHERE APPLICABLE)
- SMOKE DETECTOR (DIRECT WIRED)
- DOWNPIPE (STORMWATER CONNECTED)
- DOWNPIPE (WATER TANK CONNECTED)
ENERGY EFFICIENCY
CLASS 1 BUILDINGS IN CLIMATE ZONE 7 ARE REQUIRED TO ACHIEVE A MIN. 6 STAR ENERGY RATING IN ACCORDANCE WITH PART 3.12 OF THE NCC 2016. THIS IS ACHIEVED USING THE (DEEMED TO SATISFY PROVISIONS) OF PART 3.12 OF THE BCA. REFER TO ATTACHED REPORT FOR EXPLANATORY INFORMATION & OVERALL R-VALUES OF ROOF, WALL & FLOOR SYSTEMS
INSULATION VALUES
- ROOF: R- 5.0 BATTS (210mm) + REFLECTIVE FOIL INSULATION*
- WALLS: R- 2.5 WALL BATTS (90mm)
- FLOOR: R- 2.1 UNDERFLOOR BATTS (75mm)
* NOTE: REFLECTIVE FOIL INSULATION ASSUMES A SINGLE FOIL SIDED TYPE & POLY WEAVE BACKED WITH AN AVERAGE EMITTANCE VALUE OF 0.9 OUTER & 0.05 INNER. THE REFLECTIVE SIDE MUST FACE DOWNWARD (ROOF) OR INWARD (WALLS) AND BE PLACED DIRECTLY UNDER THE ROOF & WALL CLADDING TO BE EFFECTIVE
EXTERNAL GLAZING
- EXTERNAL GLAZING IS SUBJECT TO BUILDING ORIENTATION; REFER TO ATTACHED GLAZING CALCULATION FOR SPECIFIC BUILDING ORIENTATION
BUILDING SEALING
- A SEAL TO RESTRICT AIR INFILTRATION MUST BE FITTED TO EACH EDGE OF AN EXTERNAL SLIDING DOOR, WINDOWS AND OPENINGS. - DRAFT PROTECTORS ARE REQUIRED TO BE FITTED TO THE BOTTOM EDGE OF EXTERNAL SWING DOORS AND SEALS TO THE HEAD AND SIDES. - SEALS MAY BE FOAM, RUBBER, FIBROUS OR THE LIKE. - EXHAUST FANS MUST BE FITTED WITH A SELF SEALING DEVICE SUCH AS A SELF-CLOSING DAMPER OR FILTER (RANGEHOOD) - GAPS AND CRACKS AROUND ROOFS, EXTERNAL FLOORS, WALL/FLOOR/ROOF JUNCTIONS AND AROUND WINDOW AND DOOR FRAMES MUST BE MINIMISED THROUGH GOOD CONSTRUCTION PRACTICE. AND WITH THE PLACING OF CLOSE FITTING INTERNAL LINING AT JUNCTIONS, CAULKING, SKIRTING, ARCHITRAVES AND CORNICES.
SERVICES
- SERVICES PIPING AND DUCTWORK MUST COMPLY WITH THE MIN. INSULATION REQUIREMENTS OF PART 3.12.5 OF THE NCC 216.
WATERPROOFING & WATER RESISTANCE ALL WET AREA FLOORS:
- ENSURE VINYL FLOORING IS DEEMED TO BE WATERPROOF & THAT ALL JOINS ARE SEALED - UPTURN VINYL MIN. 25mm AT WALL/FLOOR JUNCTIONS TO CREATE WATERPROOF WATER STOP. SKIRTING BOARDS & ARCHITRAVES PLACED OVER UPTURN & SEALED TO VINYL WITH WATERPROOF ACRYLIC OR SILICONE SEALANT (REFER TO DETAIL) - SKIRTING BOARDS & ARCHITRAVES TO WET AREAS TO BE SOLID TIMBER (IE. PINE OR HARDWOOD, NOT MDF)
SHOWER CUBICLE:
- 42x42x3mm ALUMIN. WATERSTOP ANGLE OR VINYL FLOORING STRIP WITH MIN. HORIZONTAL DIMENSION OF 40mm EITHER SIDE, SEALED TO WALL AT ALL WALL JUNCTIONS (CORNERS) EXTENDING A MIN. OF 1800mm FROM SHOWER BASE - THERMOSET LAMINATE WALL PANELS MIN. OF 1800mm HIGH FROM SHOWER BASE
ABOVE BASINS, TROUGHS & SINKS (KITCHEN BENCH)
- 150mm HIGH WALL TILES MIN. ABOVE VESSELS WITH WATERPROOF ACRYLIC OR SILICONE SEALANT TO JUNCTIONS
ELECTRICAL NOTES - LIGHT SWITCHES TO BE AT 1000mm ABOVE FLOOR LEVEL. - HEIGHTS OF POWER POINTS MEASURED FROM FLOOR LEVEL UNLESS OTHERWISE NOTED. - UNLESS DIMENSIONED POWER POINTS TO BE LOCATED TO THE NEAREST STUD. - POWER POINTS FOR APPLIANCES & SPLIT SYSTEM AIR-CONDITIONING TO SUIT MANUFACTURERS REQ. - PROVIDE PHONE CABLING WITH CONDUIT & DRAW STRING PLUS T.V. ANTENNA CABLING THROUGH BARGE END.
ENERGY EFFICIENCY- LIGHTING - ARTIFICIAL LIGHTING MUST NOT EXCEED: CLASS 1 BUILDINGS- 5 W/m2
VERANDAH/PORCH- 4W/m2
PERIMETER LIGHTING- MIN. 40 LUMENS/W IN ACCORDANCE WITH THE NCC 2016 PART 3.12
- INTERNAL LIGHTING MUST NOT EXCEED: 445 WATTS TOTAL
- PERIMETER LIGHTING COMPLIANT WITH: 8 WATT CFL GLOBE= 50 LUMENS/W 11 WATT CFL GLOBE= 73 LUMENS/W
BUSHFIRE AREAS DESIGN & SPECIFICATION DOES NOT CONSIDER SITES SUBJECT TO BUSHFIRE ATTACK. SITES DEEMED TO HAVE A BAL OF 12.5 OR MORE HAVE ADDITIONAL CONSTRUCTION REQUIREMENTS IN ACCORDANCE WITH PART 3.7.4 OF THE NCC 2016 & AS 3959
TERMITE AREAS THE PLACEMENT OF A CHEMICAL BARRIER OR SHEET METAL "ANT CAPS" TO THE TOPS OF TIMBER STUMPS IN ACCORDANCE WITH PART 3.1.3 OF THE NCC 2016 & AS 3660.1 IS SUFFICIENT WHEN PROTECTION AGAINST TERMITE ATTACK IS REQUIRED
NOTE: A MIN. OF 400mm CLEARANCE IS REQUIRED TO THE UNDERSIDE OF BEARERS ON SITES REQUIRING TERMITE INSPECTION. THIS CAN BE REDUCED TO 150mm ON SLOPING SITES WITHIN 2m OF EXTERNAL WALLS.
SPECIFICATION FOOTINGS - "TYPE 1" FOOTINGS TO AS 1684.2 200 x 225 x 38 TIMBER SOLE PLATES DURABILITY CLASS 1 OR 2 OR H5 TREATED
MIN. SOLE PLATE FOUNDING DEPTHS: IN ACCORDANCE WITH AS 2870
SITE CLASSIFICATION MIN. DEPTH
A, S, M 500mm M-D 800mm H 1000mm
NOTE: SOLE PLATES MUST ALSO BE FOUNDED A MIN. OF 100mm INTO NATURAL SOIL WITH A MIN. BEARING CAPACITY OF 100 kPa. A DEEPER FOUNDING DEPTH MAY BE REQUIRED TO ACHIEVE THIS
STUMPS - 100x100 MIN. TIMBER STUMPS OF A DURABILITY CLASS 1 OR 2 OR H5 TREATED WITH A MIN. STRESS GRADE OF F4
BEARERS ROOF LOAD WIDTH- 4000mm FLOOR LOAD WIDTH- 1900mm INTERNALLY - 1700mm ON EXT. WALLS
- 2/90x45 MGP10 BEARERS WITH A MAX. CONTINUOUS SPAN OF 1600mm or
- 2/90x45 F5 BEARERS WITH A MAX. CONTINUOUS SPAN OF 1400mm
MINIMUM BEARER CLEARANCE TO GROUND LEVEL:
TERMITE INSPECTION REQUIRED: NOT REQUIRED:
150mm 400mm
NOTE: ON SLOPING SITES, 400mm WHEN REQUIRED MAY BE REDUCED TO 150mm WITHIN 2m OF EXTERNAL WALLS
FLOOR JOISTS - 90x45 MGP10 FLOOR JOISTS AT MAX. 450 CENTRES WITH A: MAX. CONTINUOUS OF 1800mm MAX. SINGLE SPAN OF 1300mm or
- 90x45 F5 FLOOR JOISTS AT MAX. 450 CENTRES WITH A: MAX. CONTINUOUS OF 1600mm
FLOORING
19mm THICK "YELLOW TONGUE" PARTICLEBOARD FLOORING.
TIMBER DURABILITY CLASS 1 OR 2 TIMBERS ARE SUITABLE FOR IN GROUND USE. ALTERNATIVELY, H5 TREATED TIMBER CAN BE USED
CLASS 1 CLASS 2
BELIAN BLACKBUTT CYPRESS (WHITE) KWILA (MERBAU) IRONBARK SPOTTED GUM TALLOWWOOD WESTERN RED CEDAR TURPENTINE RIVER RED GUM YELLOW CEDAR BALAU NORTHERN BOX TEAK
WALL FRAMES - COMMON STUDS: 90x35 F5 AT 600 CTS. - TOP PLATES: 2/35x90 F5 - BOTTOM PLATES: 45x90 MGP10 - NOGGINGS: 90x35 AT 1275 CTS. - JAMB STUDS: OPENING 0 - 900: 90x35 F5 OPENING 900 - 2600: 2/90x35 F5 OPENING 2600 - 4300: 3/90x35 F5
LINTELS - OPENINGS UP TO 1100: 90 x 45 F5 - OPENINGS UP TO 1500: 90 x 45 LVL 15 - OPENINGS UP TO 1800: 140 x 45 F7 - OPENINGS UP TO 2200: 140 x 45 LVL 15 - OPENINGS UP TO 2400: 190 x 45 F7 - OPENINGS UP TO 2600: 190 x 45 MGP10 - OPENINGS UP TO 3000: 240 x 45 F7
*ALL STRUCTURAL TIMBER SIZES, FIXINGS & TIE-DOWNS ARE TO BE IN ACCORDANCE WITH AS 1684.2 2010
BAL 12.5CONSTRUCTION IN ACCORDANCE WITH
AS 3959-2009 FOR A BAL OF 12.5
GSPublisherVersion 0.0.100.100
Callen Bray BA(Arch), BArch.(Hons) (Deakin)
Building Design & DraftingResidential - Commercial - Industrial
ABN: 38 040 205 161Phone: 0419 441 186
Email: [email protected] Building Practitioner: DP-AD 36967
Sheet No: 2Issue: 4/04/17Rev: 1
7.8m x 12.5m2 Bedroom
Proposed DPU,At: No. 515 Beenak Road, Seville, VIC, 3139For: Margaretha Derksen
DP
DP
RA
S/BI/WE .............................................................................................................................
ACKNOWLEDGE THAT THESE PLANS ARE A TRUE AND ACCURATEREFLECTION OF OUR REQUIREMENTS AND AGREE THAT THESEPLANS ARE THE PLANS REFFERED TO IN THE MAJOR DOMESTICBUILDING CONTRACT BETWEEN "BETNALE PTY LTD"(TRADING AS SUPERIOR GRANNY FLATS) AND MYSELF/OURSELVESAND AUTHORISE THEIR USE FOR NEXT STAGE PURPOSES. I/WE AM/AREFULLY AWARE, IF ANY FURTHER CHANGES ARE TO BE MADE ON THESEPLANS WILL INCUR A VARIATION FEE.
SIGNED: .............................................................................. DATE: ............................
SIGNED: .............................................................................. DATE: ............................
Lounge
Section X-X
0F.L
2,100WIND HEADS
PorchMeals
300
2,70
0 190x45 F7 H3TREATED PINEBEAMS OVERPORCH
ROOF TRUSSES TOMANUFACT. DESIGN& DETAILS AT 900 CTS.
EAVE & VERGE(FACE FRAME TOBACK FASCIA)
O/A
PLA
TES
MIN
. SOL
EPL
ATE
DEP
TH
LOADBEARING WALL
STRAMIT COLORBONDCORRUGATED ROOFINGAT 15° WITH FULL SARKING
35x70 MGP10ROOF BATTENSAT 900 CTS.
2,700T/PLATE
1,00
0
2,700T/PLATE
0F.L
2,100WIND HEADS
OSCUREGLAZED
OSCUREGLAZED
WIN
DOW
HEA
D
PROFILED METAL FASCIA& ZINCALUME GUTTERS
STRAMIT COLORBOND CORRUGATEDROOFING AT 15° WITH FULL SARKING
150mm H3 TREATEDPINE BASEBOARDSWITH 30mm GAPS
200mm F.C. PLANKINGMIN. 6mm THICKFOR BAL 12.5
EXTERNAL VENTS FITTED WITHEMBER GUARDS OF MAX. 2mmAPERTURE STAINLESS STEEL,BRONZE OR ALUMINIUM MESH.
FLY SCREENS TOOPENABLE PORTIONOF ALL WINDOWS WITHA MAX. 2mm APERTURES/STEEL, BRONZE ORALUMINIUM MESH.
SEALED PVC DP'S FORCHARGED RAINWATERHARVESTING SYSTEM
-1,200G.L
Elevation D (South)
LPG CYLINDERPOSITION
2,48
0
Elevation B (North)
2,100WIND HEADS
2,700T/PLATE
0F.L
G.L
150mm SPOTTED GUMTIMBER BASEBOARDSTO PORCH SUB-FLOORONLY WITHIN 400mmOF G.L FOR BAL 12.5
HORIZ. & VERT H/RAIL GAPSMUST BE LESS THAN 125mmWHERE LANDING HEIGHTEXCEEDS 1000mm ABOVEG.L. (NCC 2016 PART 3.9.2)
150mm H3 TREATEDPINE BASEBOARDSWITH 30mm GAPS
200mm F.C. PLANKINGMIN. 6mm THICK
FOR BAL 12.5
40x40 EAALUMINIUMCORNERS
MIN
IMUM
PROFILED METAL FASCIA& ZINCALUME GUTTERS
STRAMIT COLORBOND CORRUGATEDROOFING AT 15° WITH FULL SARKING
FLY SCREENS TO OPENABLE PORTIONOF ALL WINDOWS WITH A MAX. 2mm APERTURES/STEEL, BRONZE OR ALUMINIUM MESH.
SELECTENTRY DOOR
- MOUNTAIN ASH (VIC ASH, TASMANIAN OAK) SOLID TIMBER DOOR FRAME
- SOLID OR LAMINATED TIMBER DOOR MIN. 35mm THICK WITH GLAZING PANELS LESS THAN 400mm ABOVE G.L OR DECKING TO BE MIN. 4mm GRADE A SAFETY GLASS. THICKER GLAZING MAY BE ANNEALED GLASS
SEALED PVC DP'S FORCHARGED RAINWATERHARVESTING SYSTEM
APP
ROX.
TIMBER SUB-FLOOR CROSS BRACINGUNITS IN ACCORDANCE WITH AS 1684.2(REFER TO SECTION 8.3.5 FOR DETAILS)140x45 H3 TREATED PINE AT BETWEEN30o - 60o WITH 4/No. 14 TYPE 17 SCREWS
2,0
00
1,00
0
2,700T/PLATE
0F.L
2,100WIND HEADS
RAMPED WALKWAY AT MAX.1 IN 14 GRADIENT & MIN.1m CLEAR BETWEEN H/RAILS
STRAMIT COLORBONDCORRUGATED ROOFINGAT 15° WITH FULL SARKING
PROFILED COLORBONDBARGE & CAPPING
150mm SPOTTED GUM TIMBER BASEBOARDSTO PORCH SUB-FLOOR ONLY WITHIN 400mmOF G.L FOR BAL 12.5
MIN
IMUM
HORIZ. & VERT H/RAIL GAPS MUST BE LESSTHAN 125mm WHERE LANDING HEIGHT EXCEEDS1000mm ABOVE G.L. (NCC 2016 PART 3.9.2)
APP
ROX.
SEALED PVC DP'S FORCHARGED RAINWATERHARVESTING SYSTEM
Elevation A (East)
2,0
00
1,00
0
650
1085
500
-
SINK6
7
9
8
DW
TROUGH
WM
ABOVE FFL No.
600
10 FR WASTE
WATER PIPE LOCATIONS
1000/1800
600
BIDET
BATH
SHOWER4
3
2
1
BASIN5
No.
TOILET
ITEM ITEM
FRAME OFFSETS: SHOWER ROSE= 430 CL, SHOWER TAPS= 250 CL, SOAP HOLDER= 550 CL
600/1275
250
250
TOWEL RING
ITEM HEIGHT ABOVE FFL
1000 NOMINAL
820
1000/1600
820
SHOWER SOAP HOLDER
TOWEL RAIL
PAPER HOLDER
FITTING LOCATIONS
NOTES: - DIMENSIONS TAKEN FROM FRAME
INTERNAL ELEVATIONS SPECIFICATION
ABOVE FFL
- WET AREA SKIRTING BOARDS: SOLID TIMBER 67mm
- SPLASHBACK TILES: 200x200
- POWERPOINT LOCATION
- CEILING LIGHT OUTLET (240v)
- PHONE POINT AT 200/1000
- EXHAUST FAN (SELF SEALING)
- T.V. POINT AT 200
- SMOKE DETECTOR (DIRECT WIRED)
- INTERNAL SWITCH BOARD
ELECTRICAL LEGEND
1350 F.F.L
1275 F.F.L
1400 F.F.L
2000 F.F.L
IN ROOF
HEIGHTSPP DPP
750 F.F.L
1200 F.F.L
DPP
200 F.F.L
350 F.F.L
970 F.F.L
1000F.F.L
HEIGHT
1000 F.G.L
SPP
2,700T/PLATE
0F.L
2,100WIND HEADS
A/CCONDUNIT
STRAMIT COLORBONDCORRUGATED ROOFINGAT 15° WITH FULL SARKING
PROFILED COLORBONDBARGE & CAPPING
40x40 EAALUMINIUMCORNERS
200mm F.C. PLANKINGMIN. 6mm THICK
FOR BAL 12.5
FLY SCREENS TOOPENABLE PORTIONOF ALL WINDOWS WITHA MAX. 2mm APERTURES/STEEL, BRONZE ORALUMINIUM MESH.
150mm SPOTTED GUM TIMBER BASEBOARDSTO PORCH SUB-FLOOR ONLY WITHIN 400mmOF G.L FOR BAL 12.5
150mm H3 TREATEDPINE BASEBOARDSWITH 30mm GAPS
TIMBER SUB-FLOOR CROSS BRACINGUNITS IN ACCORDANCE WITH AS 1684.2(REFER TO SECTION 8.3.5 FOR DETAILS)140x45 H3 TREATED PINE AT BETWEEN30o - 60o WITH 4/No. 14 TYPE 17 SCREWS
Elevation C (West)
A
450
400
450
900
1,300
1,700
150 1,200
200
LINEN
BULKHEAD
LINE
N S
HEL
VES
VANITY
TILE
S
450mmDEEP
B
460VANITY
SKIRTINGTILES
C
1,10
0
430
1,80
0
1,00
0
80
0
1,050
150
2,20
0
1,600T.R
T.R
MIXER/GRABRAIL
OUTL
ET /
TOP
SH
OWER
RA
IL
MIX
ER
350L.GRABRAILAT 90o
TOP
GRA
BRA
IL 750L. GRABRAIL
GRA
BRA
IL
GRABRAIL
O/A
LL T
ILES
SKIRTINGTILES
SEAT
D
450
2,17
0
140
2,0
30
565 4514
020
014
0 1,830
1,80
0
140x45NOGGIN'S
SEAT
OVER
ALL
LIN
EN
KICK
ER 1200x900STEPLESS
SHOWER BASELINEN
O/A
LL S
HOW
ER S
CREE
N
O/A
LL T
ILES
ROUTEDDOORS
400 DEEPBULKHEAD
OVER
450mmDEEP
A
1,515310
600275900900400600
1,000 620
SINK
OVER
ALL
O/H
EADS
KICK
ER
O/HEADS
CARCASS
PANTRY B/TOP
POT DRAWS CARCASS
ROUTEDDOORS
140
760
670
60
0
2,17
0
900
200
BENC
HTO
PTI
LES
B
1,850
320
CARCASSREF. SPACE
PANTRY
OVER
ALL
O/H
EADS
KICK
ER
REF.
SPA
CE
ROUTEDDOORS
140
760
670
60
0
2,17
0
900
200
BENC
HTO
PTI
LES
1,000
16 900 16 550 400 600
C
6209952016
450700300600
620
1,850
320
310
BENC
HTO
P
OVER
ALL
O/H
EADS
CARCASS
B/TOP
DRAWS
REFPOS
APPROX. TOPLASTERB'D
REF.
SPA
CE
O/HEADS
ROUTEDDOORS
POT DRAWS14
076
06
706
00
2,17
0
900
D
7501,200620
13016585320600320600
16 900 600 750 300
TILE
S
BENC
HTO
P
OVER
ALL
O/H
EADS
KICK
ER
EXT. VENTEDSLIDEOUT
RANGEHOOD
CARCASS
B/TOP
CARCASS
SERVERYB/TOP TO B/TOP
R/HOOD
300x300CHAMFEREDCORNERSHELF UNIT
ROUTEDDOORS
140
760
670
60
0
2,17
0
900
C
60
0
300
200
WMSPACE
45 Lt.TROUGH
TILE
S
WM TAPS
WM
TA
PS
W/M TAPSIN VANITY
C
850
650
700
750
T.P.H
GRABRAIL
GRA
BRA
IL
300L.GRABRAILAT 30o
SKIRTING TILES
T.P.
H
C
520TOILET
GENERAL NOTES
- ENERGY EFFICIENCY (WALL, FLOOR, ROOF INSULATION & GLAZING) IN ACCORDANCE WITH PART 3.12 OF THE NCC 2016: REFER TO ENERGY EFFICIENCY NOTES & GLAZING CALCULATIONS FOR DETAILS.
- WET AREAS IN ACCORDANCE WITH PART 3.8.1 OF THE NCC 2016 FOR WATERPROOFING & WATER RESISTANCE.
- STEPS: TREAD- 250mm MIN, RISER- 190mm MAX.
- BALUSTRADE : - AT STEPS- 865mm (MIN) HIGH - AT LANDING- 1000mm (MIN) HIGH
- WHERE REQUIRED, HORIZONTAL & VERT. GAPS IN BALUSTRADES MUST BE LESS THAN 125mm IN ACCORDANCE WITH NCC 2016 PART 3.9.2
- WRITTEN DIMENSIONS WILL TAKE PRECEDENCE OVER SCALE.
- UNLESS OTHERWISE INDICATED ALL WALL DIMENSIONS ARE: - EXTERNAL 90mm STUD - INTERNAL 90mm STUD
- WC / BATHROOM DOOR TO BE REMOVABLE WHERE REQUIRED AND FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH NCC 2016 PART 3.8.3.3
- ALL GLAZING TO COMPLY WITH PART 3.6 OF THE NCC 2016 & AS 1288
- MECHANICAL VENTILATION TO OUTSIDE AIR PROVIDED WHERE REQUIRED AND IN ACCORDANCE WITH NCC 2016 P.2.4.5 / 3.8.5
- ROOF TRUSSES (WHERE USED) TO HAVE A MAXIMUM SPACING OF 900mm
- WINDOW GLAZING CODES: - (OBS) OBSCURE GLASS - (TLS) TRANSLUCENT GLASS - (DG) DOUBLE GLAZED
- ROOF ACCESS (WHERE APPLICABLE)
- SMOKE DETECTOR (DIRECT WIRED)
- DOWNPIPE (STORMWATER CONNECTED)
- DOWNPIPE (WATER TANK CONNECTED)
ENERGY EFFICIENCY
CLASS 1 BUILDINGS IN CLIMATE ZONE 7 ARE REQUIRED TO ACHIEVE A MIN. 6 STAR ENERGY RATING IN ACCORDANCE WITH PART 3.12 OF THE NCC 2016. THIS IS ACHIEVED USING THE (DEEMED TO SATISFY PROVISIONS) OF PART 3.12 OF THE BCA. REFER TO ATTACHED REPORT FOR EXPLANATORY INFORMATION & OVERALL R-VALUES OF ROOF, WALL & FLOOR SYSTEMS
INSULATION VALUES
- ROOF: R- 5.0 BATTS (210mm) + REFLECTIVE FOIL INSULATION*
- WALLS: R- 2.5 WALL BATTS (90mm)
- FLOOR: R- 2.1 UNDERFLOOR BATTS (75mm)
* NOTE: REFLECTIVE FOIL INSULATION ASSUMES A SINGLE FOIL SIDED TYPE & POLY WEAVE BACKED WITH AN AVERAGE EMITTANCE VALUE OF 0.9 OUTER & 0.05 INNER. THE REFLECTIVE SIDE MUST FACE DOWNWARD (ROOF) OR INWARD (WALLS) AND BE PLACED DIRECTLY UNDER THE ROOF & WALL CLADDING TO BE EFFECTIVE
EXTERNAL GLAZING
- EXTERNAL GLAZING IS SUBJECT TO BUILDING ORIENTATION; REFER TO ATTACHED GLAZING CALCULATION FOR SPECIFIC BUILDING ORIENTATION
BUILDING SEALING
- A SEAL TO RESTRICT AIR INFILTRATION MUST BE FITTED TO EACH EDGE OF AN EXTERNAL SLIDING DOOR, WINDOWS AND OPENINGS. - DRAFT PROTECTORS ARE REQUIRED TO BE FITTED TO THE BOTTOM EDGE OF EXTERNAL SWING DOORS AND SEALS TO THE HEAD AND SIDES. - SEALS MAY BE FOAM, RUBBER, FIBROUS OR THE LIKE. - EXHAUST FANS MUST BE FITTED WITH A SELF SEALING DEVICE SUCH AS A SELF-CLOSING DAMPER OR FILTER (RANGEHOOD) - GAPS AND CRACKS AROUND ROOFS, EXTERNAL FLOORS, WALL/FLOOR/ROOF JUNCTIONS AND AROUND WINDOW AND DOOR FRAMES MUST BE MINIMISED THROUGH GOOD CONSTRUCTION PRACTICE. AND WITH THE PLACING OF CLOSE FITTING INTERNAL LINING AT JUNCTIONS, CAULKING, SKIRTING, ARCHITRAVES AND CORNICES.
SERVICES
- SERVICES PIPING AND DUCTWORK MUST COMPLY WITH THE MIN. INSULATION REQUIREMENTS OF PART 3.12.5 OF THE NCC 216.
WATERPROOFING & WATER RESISTANCE ALL WET AREA FLOORS:
- ENSURE VINYL FLOORING IS DEEMED TO BE WATERPROOF & THAT ALL JOINS ARE SEALED - UPTURN VINYL MIN. 25mm AT WALL/FLOOR JUNCTIONS TO CREATE WATERPROOF WATER STOP. SKIRTING BOARDS & ARCHITRAVES PLACED OVER UPTURN & SEALED TO VINYL WITH WATERPROOF ACRYLIC OR SILICONE SEALANT (REFER TO DETAIL) - SKIRTING BOARDS & ARCHITRAVES TO WET AREAS TO BE SOLID TIMBER (IE. PINE OR HARDWOOD, NOT MDF)
SHOWER CUBICLE:
- 42x42x3mm ALUMIN. WATERSTOP ANGLE OR VINYL FLOORING STRIP WITH MIN. HORIZONTAL DIMENSION OF 40mm EITHER SIDE, SEALED TO WALL AT ALL WALL JUNCTIONS (CORNERS) EXTENDING A MIN. OF 1800mm FROM SHOWER BASE - THERMOSET LAMINATE WALL PANELS MIN. OF 1800mm HIGH FROM SHOWER BASE
ABOVE BASINS, TROUGHS & SINKS (KITCHEN BENCH)
- 150mm HIGH WALL TILES MIN. ABOVE VESSELS WITH WATERPROOF ACRYLIC OR SILICONE SEALANT TO JUNCTIONS
ELECTRICAL NOTES - LIGHT SWITCHES TO BE AT 1000mm ABOVE FLOOR LEVEL. - HEIGHTS OF POWER POINTS MEASURED FROM FLOOR LEVEL UNLESS OTHERWISE NOTED. - UNLESS DIMENSIONED POWER POINTS TO BE LOCATED TO THE NEAREST STUD. - POWER POINTS FOR APPLIANCES & SPLIT SYSTEM AIR-CONDITIONING TO SUIT MANUFACTURERS REQ. - PROVIDE PHONE CABLING WITH CONDUIT & DRAW STRING PLUS T.V. ANTENNA CABLING THROUGH BARGE END.
ENERGY EFFICIENCY- LIGHTING - ARTIFICIAL LIGHTING MUST NOT EXCEED: CLASS 1 BUILDINGS- 5 W/m2
VERANDAH/PORCH- 4W/m2
PERIMETER LIGHTING- MIN. 40 LUMENS/W IN ACCORDANCE WITH THE NCC 2016 PART 3.12
- INTERNAL LIGHTING MUST NOT EXCEED: 445 WATTS TOTAL
- PERIMETER LIGHTING COMPLIANT WITH: 8 WATT CFL GLOBE= 50 LUMENS/W 11 WATT CFL GLOBE= 73 LUMENS/W
BUSHFIRE AREAS DESIGN & SPECIFICATION DOES NOT CONSIDER SITES SUBJECT TO BUSHFIRE ATTACK. SITES DEEMED TO HAVE A BAL OF 12.5 OR MORE HAVE ADDITIONAL CONSTRUCTION REQUIREMENTS IN ACCORDANCE WITH PART 3.7.4 OF THE NCC 2016 & AS 3959
TERMITE AREAS THE PLACEMENT OF A CHEMICAL BARRIER OR SHEET METAL "ANT CAPS" TO THE TOPS OF TIMBER STUMPS IN ACCORDANCE WITH PART 3.1.3 OF THE NCC 2016 & AS 3660.1 IS SUFFICIENT WHEN PROTECTION AGAINST TERMITE ATTACK IS REQUIRED
NOTE: A MIN. OF 400mm CLEARANCE IS REQUIRED TO THE UNDERSIDE OF BEARERS ON SITES REQUIRING TERMITE INSPECTION. THIS CAN BE REDUCED TO 150mm ON SLOPING SITES WITHIN 2m OF EXTERNAL WALLS.
SPECIFICATION FOOTINGS - "TYPE 1" FOOTINGS TO AS 1684.2 200 x 225 x 38 TIMBER SOLE PLATES DURABILITY CLASS 1 OR 2 OR H5 TREATED
MIN. SOLE PLATE FOUNDING DEPTHS: IN ACCORDANCE WITH AS 2870
SITE CLASSIFICATION MIN. DEPTH
A, S, M 500mm M-D 800mm H 1000mm
NOTE: SOLE PLATES MUST ALSO BE FOUNDED A MIN. OF 100mm INTO NATURAL SOIL WITH A MIN. BEARING CAPACITY OF 100 kPa. A DEEPER FOUNDING DEPTH MAY BE REQUIRED TO ACHIEVE THIS
STUMPS - 100x100 MIN. TIMBER STUMPS OF A DURABILITY CLASS 1 OR 2 OR H5 TREATED WITH A MIN. STRESS GRADE OF F4
BEARERS ROOF LOAD WIDTH- 4000mm FLOOR LOAD WIDTH- 1900mm INTERNALLY - 1700mm ON EXT. WALLS
- 2/90x45 MGP10 BEARERS WITH A MAX. CONTINUOUS SPAN OF 1600mm or
- 2/90x45 F5 BEARERS WITH A MAX. CONTINUOUS SPAN OF 1400mm
MINIMUM BEARER CLEARANCE TO GROUND LEVEL:
TERMITE INSPECTION REQUIRED: NOT REQUIRED:
150mm 400mm
NOTE: ON SLOPING SITES, 400mm WHEN REQUIRED MAY BE REDUCED TO 150mm WITHIN 2m OF EXTERNAL WALLS
FLOOR JOISTS - 90x45 MGP10 FLOOR JOISTS AT MAX. 450 CENTRES WITH A: MAX. CONTINUOUS OF 1800mm MAX. SINGLE SPAN OF 1300mm or
- 90x45 F5 FLOOR JOISTS AT MAX. 450 CENTRES WITH A: MAX. CONTINUOUS OF 1600mm
FLOORING
19mm THICK "YELLOW TONGUE" PARTICLEBOARD FLOORING.
TIMBER DURABILITY CLASS 1 OR 2 TIMBERS ARE SUITABLE FOR IN GROUND USE. ALTERNATIVELY, H5 TREATED TIMBER CAN BE USED
CLASS 1 CLASS 2
BELIAN BLACKBUTT CYPRESS (WHITE) KWILA (MERBAU) IRONBARK SPOTTED GUM TALLOWWOOD WESTERN RED CEDAR TURPENTINE RIVER RED GUM YELLOW CEDAR BALAU NORTHERN BOX TEAK
WALL FRAMES - COMMON STUDS: 90x35 F5 AT 600 CTS. - TOP PLATES: 2/35x90 F5 - BOTTOM PLATES: 45x90 MGP10 - NOGGINGS: 90x35 AT 1275 CTS. - JAMB STUDS: OPENING 0 - 900: 90x35 F5 OPENING 900 - 2600: 2/90x35 F5 OPENING 2600 - 4300: 3/90x35 F5
LINTELS - OPENINGS UP TO 1100: 90 x 45 F5 - OPENINGS UP TO 1500: 90 x 45 LVL 15 - OPENINGS UP TO 1800: 140 x 45 F7 - OPENINGS UP TO 2200: 140 x 45 LVL 15 - OPENINGS UP TO 2400: 190 x 45 F7 - OPENINGS UP TO 2600: 190 x 45 MGP10 - OPENINGS UP TO 3000: 240 x 45 F7
*ALL STRUCTURAL TIMBER SIZES, FIXINGS & TIE-DOWNS ARE TO BE IN ACCORDANCE WITH AS 1684.2 2010
BAL 12.5CONSTRUCTION IN ACCORDANCE WITH
AS 3959-2009 FOR A BAL OF 12.5
Internal Elevations- Bathroom Scale 1:50
Kitchen
L'dry WC
GSPublisherVersion 0.0.100.100
Callen Bray BA(Arch), BArch.(Hons) (Deakin)
Building Design & DraftingResidential - Commercial - Industrial
ABN: 38 040 205 161Phone: 0419 441 186
Email: [email protected] Building Practitioner: DP-AD 36967
Sheet No: 3Issue: 4/04/17Rev: 1
7.8m x 12.5m2 Bedroom
Proposed DPU,At: No. 515 Beenak Road, Seville, VIC, 3139For: Margaretha Derksen
I/WE .............................................................................................................................
ACKNOWLEDGE THAT THESE PLANS ARE A TRUE AND ACCURATEREFLECTION OF OUR REQUIREMENTS AND AGREE THAT THESEPLANS ARE THE PLANS REFFERED TO IN THE MAJOR DOMESTICBUILDING CONTRACT BETWEEN "BETNALE PTY LTD"(TRADING AS SUPERIOR GRANNY FLATS) AND MYSELF/OURSELVESAND AUTHORISE THEIR USE FOR NEXT STAGE PURPOSES. I/WE AM/AREFULLY AWARE, IF ANY FURTHER CHANGES ARE TO BE MADE ON THESEPLANS WILL INCUR A VARIATION FEE.
SIGNED: .............................................................................. DATE: ............................
SIGNED: .............................................................................. DATE: ............................
4
2
3
4
2 3
56
2
35 1 5
1
7
1
4
Report from Option 12- With Verandah- NCC GLAZING CALCULATOR VOLUME TWO v205 2014.xlsx printed 30/03/2017
NCC VOLUME TWO GLAZING CALCULATOR (first issued with NCC 2014)
Building name/description Climate zone CU CSHGC
7 CONSTANTS 4.937 0.170
Storey Floor Construction Area
Direct contact Wall insulation option chosen for 3.12.1.4
Air Movement Suspended 89m² CU CSHGC x Area
Area of storey 89m² ALLOWANCES 4.9 15.1
Area of glazing 23.1m² (26% of area of storey)
Number of rows for table below 12 (as currently displayed)
GLAZING ELEMENTS, ORIENTATION SECTOR, SIZE and PERFORMANCE CHARACTERISTICS SHADING CALCULATION DATA
Glazing element Orientation Size Performance P&H or device Exposure Size
ID
Facing
sector
Height
(m)
Width
(m)
Area
(m²)
Total
System
U-Value
(AFRC)
Total
System
SHGC
(AFRC)
P
(m)
H
(m)
P/HEs
Area
used
(m²)
U x area
/ winter
access
Element share
of % of
allowance used
SHGC x
Es x area
Element share
of % of
allowance used12
1 S 2.00 1.21 3.30 0.60 0.45 2.60 0.09 0.52 2.42 0.60 9% of 132% 0.8 9% of 53%12
2 S 0.60 0.91 3.30 0.60 0.45 0.80 0.56 0.34 0.55 0.14 2% of 132% 0.1 1% of 53%12
3 S 0.60 0.61 3.30 0.60 0.45 1.20 0.19 0.46 0.37 0.09 1% of 132% 0.1 1% of 53%12
4 S 0.90 0.91 3.30 0.60 0.45 1.50 0.15 0.48 0.82 0.20 3% of 132% 0.2 3% of 53%12
5 W 1.80 1.51 3.30 0.60 0.30 2.90 0.05 1.09 2.72 0.67 10% of 132% 1.8 22% of 53%12
6 Lounge N 2.00 1.81 3.30 0.60 1.70 2.60 0.33 0.48 3.62 0.90 14% of 132% 1.0 13% of 53%12
7 Lounge NE 2.00 0.61 3.30 0.60 1.80 2.60 0.35 0.70 1.22 0.30 5% of 132% 0.5 6% of 53%12
8 Lounge NW 2.00 0.61 3.30 0.60 1.80 2.60 0.35 0.70 1.22 0.30 5% of 132% 0.5 6% of 53%12
9 E 0.90 1.21 3.30 0.60 0.30 1.90 0.08 1.07 1.09 0.27 4% of 132% 0.7 9% of 53%12
10 Bed 1 N 2.10 2.11 4.30 0.61 2.30 2.70 0.43 0.39 4.43 1.43 22% of 132% 1.1 13% of 53%12
11 Entry E 2.10 2.11 4.30 0.61 2.90 2.50 1.16 0.42 4.43 1.43 22% of 132% 1.1 14% of 53%12
12 N 1.40 0.25 5.60 0.77 1.80 1.80 1.00 0.25 0.25 0.11 2% of 132% 0.0 1% of 53%
IMPORTANT NOTICE AND DISCLAIMER IN RESPECT OF THE GLAZING CALCULATOR
Copyright © 2014 – Australian Government, State and Territory Governments of Australia. All Rights Reserved
Kitchen
Laundry
Bed 2
CALCULATED OUTCOMES
Conductance - FAILED Solar heat gain - PASSED
Entry
Meals
Bathroom
WC
�The Glazing Calculator has been developed by the ABCB to assist in developing a better understanding of glazing energy efficiency parameters.
While the ABCB believes that the Glazing Calculator, if used correctly, will produce accurate results, it is provided "as is" and without
any representation or warranty of any kind, including that it is fit for any purpose or of merchantable quality, or functions as intended or at all.
Your use of the Glazing Calculator is entirely at your own risk and the ABCB accepts no liability of any kind.
Proposed DPU 7.8m x 12.5m
No wall insulation concession used
Description
(optional)
1
Standard
(only)
page 1 of 1
870
870
A18
00
-1510 (DG
)
A90
0-1210
(DG)
870
870
870
A210
0-2110
A2000-610
(DG)A2000-1810
(DG)A2000-610
(DG)
870
T2110-915A2100-2110
INST.LPGHWS
POSITIONGAS CYLINDERS
Ldry Bath Kit
Porch
A600-610(DG) (OBS)
A900-910(DG)
A2000-1210 (DG)A600-910(DG) (OBS)
ROBE
Meals
Lounge
Bed 2
Bed 1
Wc
Entry
N
S
NW
W E
NE
SESW
Orientation(Refer to Site Plan)
N
S
NW
W E
NE
SESW
Orientation(Refer to Site Plan)
Glazing CalculationsClimate Zone: 6Standard Air Movement
Windows 1-9: "Accent Windows"Aluminium Framed, Double Glazed, Sliding Windows.(3mm Energy Advantage / 10mm Argon Sealed / 3mm Clear)SHGC: 0.60Total U-Value: 3.3
Windows 10-11: "Accent Windows"Aluminium Framed, Single Glazed, Sliding Doors.(5mm Energy Advantage)SHGC: 0.61Total U-Value: 4.3
Window 12: Glazed Panels to Front Door, Single Clear Glazed (3mm)SHGC: 0.77 (assumed worst case)Total U-Value: 5.6 (assumed worst case)
Building Fabric R-ValuesWall Construction- Climate Zone 7- Min R-Value to be achieved R- 2.8
1. Outdoor Air Film (7 m/s) R- 0.042. F.C. Plank Cladding R- 0.093. Wall Insulation Batts (90mm) R- 2.504. Plasterboard (10mm) R- 0.065. Inside Air Film (Still Air) R- 0.12
Total R- 2.8
Roof Construction- Climate Zone 7: Upward Heat Flow- Unventilated Roof Space- 0.75 Solar Absorptance (Dark Green)- Min R-Value to be achieved R- 5.1
1. Outdoor Air Film (7 m/s) R- 0.042. Metal Roof Cladding R- 0.003. Poly Backed Ref. Foil Ins. (Ref. side down) R- 0.004. Reflective Roof Airspace R- 0.55 (as per NCC 2016 3.12.1.2)5. Ceiling Insulation Batts (210mm) R- 5.006. Plasterboard Ceiling R- 0.067. Inside Air Film (Still Air) R- 0.11
Total R- 5.8
Floor Construction- Climate Zone 7: Downward Heat Flow- Enclosed Sub-Floor- Min R-Value to be achieved R- 2.75
1. Inside Air Film (Still Air) R- 0.162. Particleboard Flooring (19mm) R- 0.153. Underfloor Insulation Batts (75mm) R- 2.104. Subfloor Air Film (Still Air) R- 0.165. Ground Thermal Resistance (Rgx) R- 0.58
Total R- 3.15
BUSHFIRE PRONE AREA - BAL: 12.5 CONSTRUCTION AS PER AS 3959-2009 FOR BAL LEVEL 12.5 SUBFLOOR SUPPORTS:- NONE
FLOORS:- NONE
EXTERNAL WALLS:- MIN. 6mm F.C WALL CLADDING. ALL JOINTS TO BE COVERED, SEALED, OVERLAPPED, BACKED OR BUTT-JOINTED TO PREVENT GAPS GREATER THAN 3mm
VENTS:- EXTERNAL VENTS FITTED WITH EMBER GUARDS OF MAX. 2mm APERTURE STAINLESS STEEL, BRONZE OR ALUMINIUM MESH.
WINDOWS & GLAZING:- FLY SCREENS OR SECURITY SCREEN WHEN FITTED TO HAVE MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH.- FLY SCREEN OR SECURITY SCREEN FRAME WHEN FITTED TO BE EITHER METAL OR BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E.- WINDOWS TO BE COMPLETELY PROTECTED BY A BUSHFIRE SHUTTER THAT COMPLIES WITH AS 3959 CLAUSE 5.5.1 OR- WINDOWS TO BE COMPLETELY PROTECTED BY EXTERNAL SCREENS WITH MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH WITH METAL OR BUSHFIRE RESISTANT TIMBER FRAME OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E. OR - WINDOW FRAMES & JOINERY TO BE METAL OR BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E. AND - EXTERNALLY FITTED HARDWARE TO BE METAL. AND - GLAZING LESS THAN 400mm ABOVE THE GROUND OR DECK TO BE MIN. 4mm GRADE A SAFETY GLASS OR THICKER GLAZING MAY BE ANNEALED (EXTERNAL LEAF IN DOUBLE GLAZING ONLY) AND - OPENABLE PORTIONS OF ALL WINDOWS TO BE SCREENED INTERNALLY OR EXTERNALLY WITH MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH WITH METAL OR BUSHFIRE RESISTANT TIMBER FRAME OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E.
EXTERNAL DOORS:- SIDE HUNG EXTERNAL DOORS AND DOOR FRAMES TO BE COMPLETELY PROTECTED BY A BUSHFIRE SHUTTER THAT COMPLIES WITH AS 3959 CLAUSE 5.5.1. OR- BE PROTECTED EXTERNALLY BY SCREENS WITH MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH WITH METAL OR BUSHFIRE RESISTANT TIMBER FRAME OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E OR
- ALTERNATIVELY DOORS AND DOOR FRAMES COMPLY WITH THE FOLLOWING: DOORS SHALL BE: - NON-COMBUSTIBLE OR - A SOLID TIMBER, LAMINATED TIMBER OR RECONSTITUTED TIMBER HAVING A MINIMUM THICKNESS OF 35mm FOR THE FIRST 400mm ABOVE THE THRESHOLD. OR - A HOLLOW CORE DOOR WITH A NON-COMBUSTIBLE KICKPLATE ON THE OUTSIDE FOR THE FIRST 400mm ABOVE THE THRESHOLD OR - BE PROTECTED EXTERNALLY BY SCREENS WITH MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH WITH METAL OR BUSHFIRE RESISTANT TIMBER FRAME OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E AND
- GLAZING PANELS LESS THAN 400mm ABOVE THE GROUND OR DECK TO BE MIN. 4mm GRADE A SAFETY GLASS OR THICKER GLAZING MAY BE ANNEALED AND- DOOR FRAMES LESS THAN 400mm ABOVE THE GROUND OR DECK TO BE METAL OR OR BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E. AND- DOORS SHALL BE TIGHT-FITTING TO THE DOOR FRAME. AND- WEATHER STRIPS, DRAUGHT EXCLUDERS OR DRAUGHT SEALS SHALL BE INSTALLED AT THE BASE OF SIDE HUNG DOORS.
ROOF:- NON-COMBUSTIBLE ROOFING (METAL) TO BE USED- ROOF/WALL JUNCTIONS TO BE SEALED TO PREVENT GAPS GREATER THAN 3mm- ROOF/GABLE/EAVES VENTS TO BE FITTED WITH EMBER GUARDS OF MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH- METAL ROOFS TO BE: - FULLY SARKED AND - HAVE GAPS GREATER THAN 3mm (UNDER CORRUGATIONS & RIBS) SEALED AT THE FASCIA OR WALL LINE WITH MAX. 2mm APERTURE STAINLESS STEEL/ BRONZE/ALUMINIUM MESH OR MINERAL WOOL INSULATION.
EAVES. FASCIAS & GABLES: EAVES, BARGES & GABLE CLADDING TO BE:- NON-COMBUSTIBLE OR- MIN. 6mm FIBRE CEMEMTOR- BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E2, APPENDIX E
- JOINS IN EAVES LININGS, FASCIAS AND GABLES MAY BE SEALED WITH PLASTIC JOINING STRIPS OR TIMBER STORM MOULDS- JUNCTIONS TO BE SEALED TO PREVENT GAPS GREATER THAN 3mm OR SEALED WITH MAX. 2mm APERTURE S/STEEL, BRONZE OR ALUMINIUM MESH
GUTTERS & DOWNPIPES:- IF INSTALLED, GUTTER GUARDS SHALL BE NON-COMBUSTIBLE
DECKS, STEPS & LANDINGS:- MATERIALS USED TO ENCLOSE THE SUB-FLOOR THAT ARE LESS THAN 400mm ABOVE THE GROUND MUST BE: - NON-COMBUSTIBLE OR - MIN. 6mm FIBRE CEMEMTOR - BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E1, APPENDIX E
- DECKING AND STAIR TREADS THAT ARE LESS THAN 400mm BELOW GLAZING ELEMENTS BE NON-COMBUSTIBLE OR BUSHFIRE RESISTANT TIMBER OR A TIMBER SPECIES SPECIFIED IN PARAGHAPH E1, APPENDIX E
BALUSTRADES & HANDRAILS:- NONE
WATER & GAS SUPPLY PIPES:- WHEN EXPOSED AND ABOVE GROUND MUST BE METAL
BUSHFIRE RESISTANT TIMBER:- SILVERTOP ASH- BLACKBUTT- RIVER RED GUM- SPOTTED GUM- RED IRONBARK- MERBAU (KWILA)- TURPENTINE
ABOVE GROUND EXPOSED TIMBER MUST ALSO BE DURABILTY CLASS 1 OR 2:
- PARAGHAPH E1, APPENDIX E COMPATIBLE SPECIES (GENERAL CONSTRUCTION): - BELIAN - BLACKBUTT - MERBAU (KWILA) - IRONBARK (RED & GREY) - TALLOWOOD - MERBAU (KWILA) - TURPENTINE - RIVER RED GUM - BALAU - NORTHERN BOX
- PARAGHAPH E2, APPENDIX E COMPATIBLE SPECIES (WINDOWS & DOORS): - BELIAN - BLACKBUTT - CYPRESS - MERBAU (KWILA) - IRONBARK (RED & GREY) - SPOTTED GUM - TALLOWOOD - TURPENTINE - RIVER RED GUM - BALAU - NORTHERN BOX
- BUSHFIRE RESISTANT TIMBER SPECIES: - BLACKBUTT - MERBAU (KWILA) - RIVER RED GUM - SPOTTED GUM - TURPENTINE
- ABOVE GROUND PROTECTED OR EXPOSED & PAINTED PARAGHAPH E2, APPENDIX E COMPATIBLE SPECIES (WINDOWS & DOORS): - MOUNTAIN ASH (VIC ASH, TASMANIAN OAK)
GSPublisherVersion 0.0.100.100
Callen Bray BA(Arch), BArch.(Hons) (Deakin)
Building Design & DraftingResidential - Commercial - Industrial
ABN: 38 040 205 161Phone: 0419 441 186
Email: [email protected] Building Practitioner: DP-AD 36967
Sheet No: 4Issue: 4/04/17Rev: 1
7.8m x 12.5m2 Bedroom
Proposed DPU,At: No. 515 Beenak Road, Seville, VIC, 3139For: Margaretha Derksen
I/WE .............................................................................................................................
ACKNOWLEDGE THAT THESE PLANS ARE A TRUE AND ACCURATEREFLECTION OF OUR REQUIREMENTS AND AGREE THAT THESEPLANS ARE THE PLANS REFFERED TO IN THE MAJOR DOMESTICBUILDING CONTRACT BETWEEN "BETNALE PTY LTD"(TRADING AS SUPERIOR GRANNY FLATS) AND MYSELF/OURSELVESAND AUTHORISE THEIR USE FOR NEXT STAGE PURPOSES. I/WE AM/AREFULLY AWARE, IF ANY FURTHER CHANGES ARE TO BE MADE ON THESEPLANS WILL INCUR A VARIATION FEE.
SIGNED: .............................................................................. DATE: ............................
SIGNED: .............................................................................. DATE: ............................
ELECTRICAL EASEMENT
DECK
EXISTINGGARAGE
DP
DP
(108.43 m)
0° 0' 4"
(127.20 m)
180° 0' 4"
72.32 m285° 15' 30"
15.76 m
9.24 m
5,400
7,200
GATE
ALL-WEATHERGRAVEL
DRIVEWAY
Lot 2No. 5150.822ha8,220m2
BEENAK ROAD
DAM
EMBANKMENT
EMBANKMENT
EMBANKMENT
JUVENILEMOUNTAIN ASH
MATUREMOUNTAIN ASH
MATUREMOUNTAIN ASH
MATUREMOUNTAIN ASH
LARGE EXOTICORNAMENTAL
JUVENILEMOUNTAIN
ASH
JUVENILEMOUNTAIN
ASH
PROPOSEDDPU
T1: MATUREMOUNTAIN ASH1,100mm DIA.
TRUNK
ALL-WEATHERGRAVEL
DRIVEWAY
T2: JEVENILEMOUNTAIN ASH500mm DIA.
TRUNK
TREE PROTECTIONZONE: 447 m2
T.P.Z
T.P.Z
SIDE SETBACK
TREE PROTECTION ZONEMINOR ENCROACHMENT5.6 m2 - 1.25% (LESS THAN 10%)
SITE COVERAGE DETAILS
OVERALL SITE AREA:
EXISTING DWELLING: EXISTING CLASS 10: PROPOSED DPU: PROPOSED DPU PORCH:
OVERALL SITE COVERAGE:
TOTAL PERMEABLE AREA:
8,220 m2
7,685 m2 (93%)
225 m2
175 m2
89 m2 (+40%)32 m2
521 m2 (6.3%)
EXISTING
POST &
WIRE FEN
CE
SITE
FAL
L
T4: MATURENATIVE
600mm DIA.TRUNK
JUVENILENATIVE
T.P.Z
T.P.Z
TREE PROTECTIONZONE: 113 m2
TREE PROTECTION ZONEMINOR ENCROACHMENT6.0 m2 - 5.3% (LESS THAN 10%)
S.R.Z
S.R.Z
SEPTICTANK SAND FILTER
90mm UPVC UNDERSLUNGSTORMWATER CONNECTEDTO WATER TANK VIA CHARGEDSYSTEM: PVC DP'S TO BE SEALEDUP TO HEIGHT OF TANK INLETOVERFLOW
L.P.O.D: WATER TANK OVERFLOWCONNECTED TO COMPLIANTRUBBLE PIT/ SOAKAGE TRENCHAS PER COUNCIL INFORMATION
DP
DP
5,20
0
6,000
3,440 13,200
6,000 2,470
EXISTINGDWELLING
EXISTINGPERGOLA
EXISTINGCARPORT
EXISTINGCARPORT
VEGETABLEGARDEN
EMBANKMENTAPPROX. 1.8m HIGH
TIMBER POST & RAIL FENCE
RAMPED WALKWAY AT MAX.1 IN 14 GRADIENT & MIN.1m CLEAR BETWEEN POSTS
SETB
AC
K TO
SH
ED
T3: JEVENILEMOUNTAIN ASH500mm DIA.
TRUNK
PROPOSED SEPTICEFFLUENT FIELD
MIN. 20,000 Lt.WATER TANK & PUMP(FOR POTABLEWATER SUPPLY)
Site PlanScale 1:200
Tree ProtectionTree Protection Zones in accordance with Australian Standard AS 4970-2009 have been applied to Native & Exotic Trees 5m ormore in height that are within the vincity of proposed building works. These Tree Protection Zones have been applied todemonstrate that the proposed building works will not encroach on these Tree Protection Zones and therefore not impact onthe health or stability of these Trees. Once the Proposed Building Work commences, the following restrictions are to beobserved and empoyed within the Tree Protection Zones in accordance with the Australian Standard AS 4970-2009:Protection of trees on development sites:
(a) The existing soil level must not be altered either by fill or excavation.(b) The soil must not be compacted or the soils drainage changed.(c) No fuels, oils, chemicals, poisons, rubbish or other materials harmful to trees are to be disposed of or stored.(d) No storage of equipment, machinery or material is to occur.(e) Open trenching to lay underground services e.g: drainage, water, gas etc. must not occur.(f) Nothing whatsoever, including temporary services wires, nails, screws or any other fixing device, is to be attached to any tree.(g) No building or any other structure is to erected.(h) Tree roots must not be severed or injured.
NOTE: WASTEWATER FROM PROPOSED DPU TO BEDISPOSED OF VIA A SEPTIC SYSTEM IN ACCORDANCE
WITH LOCAL AUTHORITY REQUIREMENTS
BAL 12.5CONSTRUCTION IN ACCORDANCE WITH
AS 3959-2009 FOR A BAL OF 12.5
GSPublisherVersion 0.0.100.100
Ca
llen Bra
y B
A(A
rch ), BA
rch .(Hons ) ( D
eakin )
Building Design & DraftingResidential - Com
mercial - Industrial
ABN : 38
040
205 16
1Phone : 0
419 441 186
Email : Callen _Bray @
Hotm
ail .comRegistered Building Practitioner : DP-A
D 3696
7
Sheet No : 5
Issue : 4/04/17
Rev : 1
7.8m
x 12.5m2 Bedroom
Proposed DPU ,A
t : No . 515 Beenak Road , S
eville , VIC , 3139For : M
argaretha Derksen
I/WE .............................................................................................................................
ACKNOW
LEDGE TH
AT TH
ESE PLA
NS A
RE A TRUE A
ND ACCURA
TEREFLECTION OF OUR REQUIREM
ENTS A
ND AG
REE THA
T THES
EPLA
NS A
RE THE PLA
NS REFFERED TO IN TH
E MA
JOR DOMES
TICBUILDING
CONTRACT BETW
EEN "BETNALE PTY LTD"
(TRADING
AS
SUPERIOR G
RANNY FLA
TS) A
ND MYS
ELF/OURSELVES
AND A
UTHORIS
E THEIR US
E FOR NEXT STA
GE PURPOS
ES. I/WE A
M/A
REFULLY A
WA
RE, IF ANY FURTH
ER CHA
NGES
ARE TO BE M
ADE ON TH
ESE
PLANS
WILL INCUR A
VARIA
TION FEE.
SIG
NED: .............................................................................. DATE: ............................
SIG
NED: .............................................................................. DATE: ............................
ELECTRIC
AL EASEMEN
T
DEC
K
EXISTING
GA
RAG
E
(108.43 m)
0° 0' 4"
69.79 m90° 0' 13"
(127.20 m)
180° 0' 4"
72.32 m285° 15' 30"
15.76 m
9.24 m
5,400
7,200
9,600
GATE
ALL-W
EATH
ERG
RAVEL
DRIVEW
AY
Lot 2
No
. 5150.822ha8,220m
2
BEENA
K ROA
D
DAM
SEASONAL CREEK
TREELINE
EMBAN
KMEN
T
EMBAN
KMEN
T
EMBAN
KMEN
T
JUVENILE
MO
UNTAIN
ASH
MATURE
MO
UNTAIN
ASH
MATURE
MO
UNTAIN
ASH
MATURE
EUCALYPTUS
MATURE
MO
UNTAIN
ASH
LARGE EXO
TICO
RNAM
ENTAL
JUVENILE
MO
UNTAIN
ASH
JUVENILE
MO
UNTAIN
ASH
PROPO
SEDD
PU
T1: MA
TUREM
OUN
TAIN
ASH
1,100mm
DIA
.TRUN
K
ALL-W
EATH
ERG
RAVEL
DRIVEW
AY
T2: JEVENILE
MO
UNTA
IN A
SH500m
m D
IA.
TRUNK
TREE PROTEC
TION
ZON
E: 447 m2
T.P.Z
T.P.Z
SIDE SETBAC
K
TREE PROTEC
TION
ZON
EM
INO
R ENC
ROA
CH
MEN
T5.6 m
2 - 1.25% (LESS TH
AN
10%)
SITE CO
VERAG
E DETA
ILS
OVERA
LL SITE AREA
:
EXISTING
DW
ELLING
: EXISTIN
G C
LASS 10:
PROPO
SED D
PU: PRO
POSED
DPU PO
RCH
:
OVERA
LL SITE CO
VERAG
E:
TOTA
L PERMEA
BLE AREA
:
8,220 m2
7,685 m2 (93%
)
225 m2
175 m2
89 m2 (+
40%)
32 m2
521 m2 (6.3%
)
EXISTING POST & WIRE FENCE
SITE FALL
T4: MA
TUREN
ATIVE
600mm
DIA
.TRUN
K
T5: MA
TURERA
DIA
TA PIN
E800m
m D
IA.
TRUNK
JUVENILE
NATIVE
T.P.Z
T.P.ZT.P.Z
TREE PROTEC
TION
ZON
E: 113 m2
TREE PROTEC
TION
ZON
EM
INO
R ENC
ROA
CH
MEN
T6.0 m
2 - 5.3% (LESS TH
AN
10%)
S.R.Z
S.R.Z
SEPTICTAN
KSAN
D FILTER
5,200
6,000
3,44013,200
6,0002,470
EXISTING
DW
ELLING
EXISTING
PERGO
LA
EXISTING
CARPO
RT
EXISTING
CARPO
RT
VEGETABLE
GARD
EN
EMBA
NKM
ENT
APPRO
X. 1.8m H
IGH
TIMBER PO
ST & RAIL FEN
CE
RAM
PED W
ALKW
AY A
T MA
X.1 IN
14 GRA
DIEN
T & M
IN.
1m C
LEAR BETW
EEN PO
STS
SETBACK TO SHED
T3: JEVENILE
MO
UNTA
IN A
SH500m
m D
IA.
TRUNK
PROPO
SED SEPTIC
EFFLUENT FIELD
Site Plan
Scale 1:30
0
Tree
Prote
ctio
nTre
e Pro
tec
tion Zo
nes in a
cc
ord
anc
e w
ith Australia
n Stand
ard
AS 4970-2009 have
be
en a
pp
lied
to N
ative
& Exo
tic Tre
es 5m
or
mo
re in he
ight tha
t are
within the
vincity o
f pro
po
sed
build
ing w
orks. The
se Tre
e Pro
tec
tion Zo
nes ha
ve b
ee
n ap
plie
d to
de
mo
nstrate
that the
pro
po
sed
build
ing w
orks w
ill not e
ncro
ac
h on the
se Tre
e Pro
tec
tion Zo
nes a
nd the
refo
re no
t imp
ac
t on
the he
alth o
r stab
ility of the
se Tre
es. O
nce
the Pro
po
sed
Building
Wo
rk co
mm
enc
es, the
follo
wing
restric
tions a
re to
be
ob
serve
d a
nd e
mp
oye
d w
ithin the Tre
e Pro
tec
tion Zo
nes in a
cc
ord
anc
e w
ith the Austra
lian Sta
nda
rd AS 4970-2009:
Prote
ctio
n of tre
es o
n de
velo
pm
ent site
s:
(a) The
existing
soil le
vel m
ust not b
e a
ltere
d e
ither b
y fill or e
xca
vatio
n.(b
) The so
il must no
t be
co
mp
ac
ted
or the
soils d
raina
ge
cha
nge
d.
(c) N
o fue
ls, oils, c
hem
ica
ls, po
isons, rub
bish o
r othe
r ma
teria
ls harm
ful to tre
es a
re to
be
disp
ose
d o
f or sto
red
.(d
) No
stora
ge
of e
quip
me
nt, ma
chine
ry or m
ate
rial is to
oc
cur.
(e) O
pe
n trenc
hing to
lay und
erg
round
servic
es e
.g: d
raina
ge
, wa
ter, g
as e
tc. m
ust not o
cc
ur.(f) N
othing
wha
tsoe
ver, inc
luding
tem
po
rary se
rvice
s wire
s, nails, sc
rew
s or a
ny othe
r fixing d
evic
e, is to
be
atta
che
d to
any tre
e.
(g) N
o b
uilding
or a
ny othe
r structure
is to e
rec
ted
.(h) Tre
e ro
ots m
ust not b
e se
vere
d o
r injured
.
NO
TE: WA
STEWA
TER FROM
PROPO
SED D
PU TO BE
DISPO
SED O
F VIA A
SEPTIC SYSTEM
IN A
CC
ORD
AN
CE
WITH
LOC
AL A
UTHO
RITY REQUIREM
ENTS
BAL 12.5
CO
NSTRUC
TION
IN AC
CO
RDAN
CE W
ITHA
S 3959-2009 FOR A BAL O
F 12.5