strudyna balcony system
DESCRIPTION
Strudyna Balcony System (SBS) was developed for use in both Residential and Commercial areas. Continue to promote maximum transparency, a departure from traditional paneled or solid balustrade which can restrict views and the movement of air. Made with 316 stainless steel components are incredibly strong & corrosion resistant; the system is also very easy to install and maintain.TRANSCRIPT
BALCONYBALCONY
SBS V2.0
systemsystem
316 Stainless Steel Modular Balcony System
Plan view
page
Assembly parts for Balcony system A for 1 set
BALCONYBALCONYsystemsystem
2
A
Balcony system A 3D Model
www. strudyna.com
Sketch elevation front viewront vieew
NO. Name Code Size
Stanchion base
Stanchion post type A (Middle)
BC1B-1008
BC1P-MD90
Stanchion post type B (End)
for 1 set
3 PCS
1 PCS
2 PCSBC2P-EN90
51mm*90mm*85mm
40mm*9mm*874mm
40mm*9mm*874mm
Stanchion angle 8 PCSBC3H-0038 38mm*77mm*40mm
EM6 Deco stud 16 PCS2960-3630 3mm M6*30mm
Cable 1x19 8 PCSCX19-0003-1597 3mm*1597mm
Flat bar handrail type A1 1 PCSBC5H-6508-2370 50.8mm*9mm*2370.4mm
Flat bar handrail type A2 1 PCSBC6H-6508-1014 50.8mm*9mm*1014.6mm
Link plate 1 PCSBC2H-0090 50mm*3mm*90mm
Cover plate 8 PCSBC1C-2803 28mm*3mm
Link adjuster 8 PCSBC1A-1208 12mm*77mm
18 PCS- Flat head socket cap screw M8*1.25*20mmAccessories
6799-1815
16 PCS- Stud anchor- Adhesive capsule anchor (HVU)
M8*80mmPBH2-688016 PCS2 PCS
M8*80mmPBH3-0880
12 PCSM8*25mm- Screw 6933-0825
16 PCS- Domed nut M66158-761026 PCSM86158-7812
26 PCS1.5mm*8.5mm*18mm6914-1381- Washer
16 PCS6mm2000-2206- Right thread nut
6 PCS14.28mm*6mmBC2B-0006- Stanchion bush
3D Model 3D Model
M82955-0830- Threaded stud
4.1
6
3.1
1
8
3.27
5
4.2
9
2
2400
1100
2400
Balcony system A was designed for buildingswhich have a one side open balcony or a corner balcony. The system is very suitable for apartmentsand condominiums where there is a requirement for the balustrade to look modern & striking. Using wire infill for the balustrade balcony system, alongside stainless steel balusters, adds transparency, increasing the available view whilst remaining very safe for high floor balconies. System A also uses a continuous handrail, increasing aesthetic appeal and safety for the dwelling owner. The system is incredibly strong, safe & easy to install and because all of the component parts are made form 316 Stainless steel, the system will endure any weather for many years.
1.
2.
3.1
3.2
4.1
4.2
5.
7.
9.
8.
6.
Plan view
Balcony System B has been designed for apartments and condominiums with a narrow balcony, which is open on just one side. Because the application is for single sided balconies and incorporates wire infill, system B is very elegant with maximum transparency. Wire infill and steel balusters allow for a panoramic view from the balcony, barely obscuring views for its owners. Furthermore, for warmer countries, the lack of a paneled balustrade structure, e.g., Glass means that wind and fresh air are able to circulate freely. This system is a viable alternative to paneled systems, potentially adding value to any apartment or condo because of increased aesthetic and functional advantages over paneled systems. System B can be easily installed and again, because of the use of 316 Stainless in all components, the system has a high resistance to corrosive environmental circumstances that might leave other systems tarnished, or worse still in need of repair.
page
3
aaalllclclconononyyy SSSySySy ttstststememem BBBB BBBBaBaBa hhhhh hasasasas bbbbb beeeeeeeennnn dddededede iisisisisigngngngng ddedededed ffffff forororor ents and condominiums with a narrow balcony, apartmes open on just one side Because the applicationwhich is
BALCONYBALCONYsystemsystem B
www. strudyna.com
Sketch elevation front view
Balcony system B 3D Model
6 PCS14.28mm*6mmBC2B-0006- Stanchion bush
Assembly parts for Balcony system B for 1 setNO. Name Code Size
Stanchion base
Stanchion post type A (Middle)
1.
2
3.1
3.2
4
5
6
7
8
BC1B-1008
BC1P-MD90
Stanchion post type B (End)
for 1 set
3 PCS
1 PCS
2 PCSBC2P-EN90
51mm*90mm*85mm
40mm*9mm*874mm
40mm*9mm*874mm
Stanchion angle 8 PCSBC3H-0038 38mm*77mm*40mm
EM6 Deco stud 16 PCS2960-3630 3mm M6*30mm
Cable 1x19 8 PCSCX19-0003-2108 3mm*2108mm
Flat bar handrail type B 1 PCSBC1H-6508-2290 50.8mm*9mm*2290mm
Cover plate 4 PCSBC1C-2803 28mm*3mm
Link adjuster 4 PCSBC1A-1208 12mm*77mm
12 PCS- Flat head socket cap screw M8*1.25*20mmAccessories
6799-1815
12 PCS- Stud anchor- Adhesive capsule anchor (HVU)
M8*80mmPBH2-688012 PCSM8*80mmPBH3-0880
16 PCS- Domed nut M66158-761024 PCSM86158-781224 PCS1.5mm*8.5mm*18mm6914-1381- Washer16 PCS6mm2000-2206- Right thread nut
12 PCSM8*25mm- Screw 6933-0825
8
1
3.1
3.2
2
24
5
w 3D Model 3D Model
7
6
2 PCSM82955-0830- Threaded stud
2400
1100
S
page
Balcony System C has been designed for apartments and condominiums with larger balcony areas. In particular, its most suitable for long terraces and those built with corners. This system has real functional & aesthetic appeal due to the continuous wires which run the entire length of the balcony perimeter. Because of the use of wire infill as opposed to paneled sections, balcony system C helps the terrace look and feel very open, promoting panoramic views and a feelingof increased space. In warmer climates, the wire infill also aids the movement of air throughout the area, supporting a relaxing balcony / terrace environment. Balcony system C continues to champion the trend for transparency, safety and functionality whilst remaining easy to install and weather resistant. Like all of the Strudyna balcony systems, the use of 316 stainless steel in the system component means that the system will continue to look great and perform its primary functions for many years, with little maintenance required.
for alcony
etic n the se of
ectionss, feel feelingg
wire t the
on thety whilst
Lik
Sketch elevation front view
BALCONYBALCONYsystemsystem
4
C
viewview
Assembly parts for Balcony system C for 1 setNO. Name Code Size
Stanchion post type A (Middle)
2.1
2.2
3.1
3.2
CX19-0003-1577 3mm*1577 mm 8 PCS9.2
CX19-0003-0392 3mm*392 mm 8 PCS9.3
Link angle 90 degree BC2A-1208 12mm*95.5mm 6 PCS7.
BC1P-MD90
Stanchion post type B (End)
for 1 set
2 PCS
6 PCSBC2P-EN90
Stanchion base 1. BC1B-1008 8 PCS51mm*90mm*85mm
40mm*9mm*874mm
40mm*9mm*874mm
Stanchion angle 16 PCSBC3H-0038 38mm*77mm*40mmStanchion angle link 2 PCSBC4H-J113 113.5mm*77mm*40mm
8. EM6 Deco stud 48 PCS2960-3630 3mm M6*30mm
CX19-0003-2392 3mm*2392 mm 8 PCS9.1 Cable 1x19Cable 1x19Cable 1x19
BC7H-6508-1850 50.8mm*9mm*1850.8mm4.1 Flat bar handrail type C1 1 PCS
BC8H-6508-2564 50.8mm*9mm*2564.1mm4.2 Flat bar handrail type C2 1 PCS4.3 BC8H-6508-A564 50.8mm*9mm*564.1mmFlat bar handrail type C2 1 PCS
6. Cover plate 4 PCSBC1C-2803 28mm*3mm5. Link adjuster 4 PCSBC1A-1208 12mm*77mm
36 PCS- Flat head socket cap screw M8*1.25*20mmAccessories
6799-1815
22 PCS- Stud anchor- Adhesive capsule anchor (HVU)
M8*80mmPBH2-688022 PCSM8*80mmPBH3-0880
48 PCS- Domed nut M66158-761072 PCSM86158-781256 PCS1.5mm*8.5mm*18mm6914-1381- Washer48 PCS6mm2000-2206- Right thread nut16 PCS14.28mm*6mmBC2B-0006- Stanchion bush
32 PCSM8*25mm- Screw 6933-0825
Balcony system C 3D Model
9.3
4.3.
4.1.
1 7
8 9.2
2.2
9.1
3.2. 3.1.6
2.1.
2.1.
5
www. strudyna.com
3D Model 3D Model
2 PCSM82955-0830- Threaded stud
page 4
Plan view
2000
700
2000
Plan view
4.2.
4
- Flat head socket cap screwAccessories
- Stud anchor- Adhesive capsule anchor (HVU)
- Domed nut
- Washer- Right thread nut
- Screw
Assembly parts for Balcony system D (Commercial)No. Name
Stanchion post type A (Middle)
2.1
2.2
3.1
3.2
Link angle 90 degree7.
Stanchion post type B (End)
Stanchion base (Flexible) 1.
Stanchion angleStanchion angle link
8. Link for double stanchion post9.
10.
EM6 Deco stud
4. Flat bar handrail type D
6. Cover plate5. Link adjuster
Code
BC2A-0C08
BC1P-MD11
BC2P-EN11
BC3B-0008
BC3H-0038BC4H-J143
BC3A-1208
2960-3630
Contact sale team
BC1C-2803BC1A-1208
Size Name Code Size
12mm*131.5mm
50mm*100mm*90mm
40mm*9mm*1074mm
40mm*9mm*1074mm
38mm*77mm*40mm143.5mm*77mm*40mm
12mm*30mm
3mm M6*30 mm
Cable 1x19 CX19-0003-xxxx 3mm*xxxx mm
50.8mm*9mm*xxxxmm
28mm*3mm12mm*77mm
www. strudyna.com
M8*1.25*20mm
M8*80mm
M8*80mm
M6M8
1.5mm*8.5mm*18mm
6mm
M8*25mmM8*30mm
M8
6799-1815
PBH2-6880
PBH3-0880
6158-76106158-7812
6914-1381
2000-2206
6933-08256933-0830
2955-0830- Threaded stud
page 5
Balcony System D was developed for use in public areas, helping to create a modern visually appealing system that also compliments any existing building infrastructure. For use indoor or outside in public areas, Strudyna Balcony System D continues to promote maximum transparency, a departure from traditional paneled or solid balustrade which can restrict view’s and the movement of air. System D, like the systems detailed previously in this brochure, is very strong and safe with a tensioned wire infill. Wire infill promotes transparency and unrestricted views beyond any perimeter. In warmer countries, the wire infill also helps aid the movement of air in any space, helping to keep the environment cool and relaxing. Made with 316 stainless steel components, balcony system D is incredibly strong & corrosion resistant; the system is also very easy to install and maintain. These features arevery desirable in public areas, especially if the balustrade is very large as this equals a significant saving in terms of installationand ongoing operational expenditure. The system will continue to look great and last for years even inharsh environmental circumstances.
Balcony system D 3D Model
Strudyna Balcony system D (Commercial)
4 M.
15.6 M.
4.8 M.
Sketch elevation right side viewPlan view
3D Model
*See more assembly parts details at page 13-16
BALCONYBALCONYBALCONYsystemsystemsystem D
page 6www. strudyna.com
AA
Rule
AA
ule
A guide to specifying Strudyna Balcony Systems
Select the type of Strudyna Balcony System which is most suitable for your terrace or balcony. Picture 1
Refer to the criteria laid out in the standard IBC of America for the conditions governing balcony design and installation. These conditions and recommendations have been summarized below.
The condition of balcony installation1) Function : (See picture no.1) The balcony is appropriate with the private area and the public area; e.g. building, apartment or condominium. The height of balcony is specified as following this.1.1 The private area should apply to the height of balcony at 900 mm. 1.2 The public area should apply to the height of balcony at 1100 mm.2) The strength of the pole: (See the picture no.2)2.1 The force all directions at 0.85 kN/m (product is not damage.) 2.2 The pressure strength of cable at 0.22 kN/m (cable is not broken.)3) The gap: (See the picture no.3)3.1 The gap between the cable; the width should not be over 102 mm. (our product has the gap at 100 mm.)3.2 The gap between the poles should not be over 1200 mm. If it is over 1200 mm, it should have the pole at the centre.4) The size of handrails: The handrails as round type, the diameter should be 35-40 mm. For the other handrails should measure the perimeter between 102-160 mm. 5) The quantity of connector for the pole and wall5.1 Link adjuster used for connecting between pole and wall- Height of the pole 900mm use 2 pcs - Height of the pole 1,100mm use 3 pcs5.2 Link angle 90 degree connect at the angle of the pole- Height of the pole 900mm use 3 pcs - Height of the pole 1,100mm use 5 pcs6) The point of angle for the top handrail has to use the connector every points: (See the picture no.5)6.1 The balcony type A use the Link plate for connecting.6.2 The balcony type B use the Stanchion angle link L shape for connecting.7) Stainless steel anchor: (See picture no.6)7.1 Use Chemical anchor- the length from the edge of cement to the drilling hole is between 50-80mm.7.2 Use Metal anchor – the length from the edge of the cement to the drilling hole 80mm up.8) Cable fitting (EM6): (See picture no.4)8.1 Use with the cable 1x19.8.2 Cable dia 3.4mm .(for the mock up sample we use cable dia 3mm)8.3 The length of cable 3.4mm dia.per piece is not over 2400mm.8.4 The height of balcony 900mm, use the cable 8 pcs.8.5 The height of balcony 1100mm, use the cable 10 pcs.9) The whole structure: ( Balcony system type A, B, C & D )9.1 All the parts with the thread, the thread have to be right hand thread.9.2 Balcony system use the thread M6 and M8 only.9.3 All the parts with the thread M6, there are used for assembly with cable fittings only.
Private areaH 900 mm.
Force All directions 0.89 kN/m.
All gap = 100 mm.
Step 1
Step 2
Link Plate
Stanchion Angle Link
Min 50 mm.
Min 50 mm.
Picture 2
Picture 3
Picture 6Picture 5Picture 4
243
Private areaH 1,100 mm.
page 7www. strudyna.com
Howto
Hot
Balcony system A
A
11 2 3 4 5 6 7 8 9 10
3 42
owwowo
Study the installation guide and follow the installation steps detailed over the following pages.
Contact the Strudyna Sales team if you require further information regarding our proprietary Balcony Systems and their installation or if you are interested in additional products, services and capability available from Strudyna.
1. Prepare all components and tools
Electric drillHex wrench/Spanner
6, 10, 13
BT7991
BFWA/E1 SFNUT/RBNUT/DIN1587
PBH3
BC1A BC1CBC2A
BC3H BC4H (Link)
Tools Nuts & Bolts
Stanchion Post Components
See more information on page 15-16
For more information please see pages 13-15
Assembly & Installation Procedures for Strudyna Balcony Systems.
Step 3
Step 4
BC3BBC1B
BC2B
BC2HBC3A
BT933
BC1P, BC2P
900 1100
BC1H, BC5H, BC6HBC7H, BC8H
PBH1 PBH2
page 8www. strudyna.com
2. Once you have organized your balcony system components, carefully follow the installation guide as laid out below and in the following pages. Assemble each post as per the below diagrams
Angled connection for handrail to wall
Post Balcony Type A,B,C (Residential) 900 mm.
Post Balcony Type D (Commercial) 1100 mm.
Assembly Procedure for Strudyna Balcony Systems A, B, C & D
Type 5
End post Middle post Corner post
Handrail with link adjuster
Link plate detail
Type 1
Angled connection for handrail to wall
Type 2 Type 3 Type 4
Type 6
End post
Type 1
Middle post
Type 2
Double post
Type 3 Corner post
Type 4
*Recommended to use Type 3 double post for every 2400 mm. (refer to the length of cable per piece is not over 2400 mm)
Type 5
page 9www. strudyna.com
Handrail with link adjusterType 4
Link plate DetailType 5
Angled connection for handrail to wall
Type 6
NO. Name Code Size
Stanchion base
Assemble each post as per the below diagrams.
Stanchion post type A (Middle)
Link adjuster
Flat bar handrail type A1
Cover plate
Stanchion angle
2.1
2.2
1.
3.1
3.2
4.1
4.2
5.
6.
7.
8.
9.10.11.
12.13.
15.14.
BC1B-1008
BC1P-MD90
Stanchion post type B (End) BC2P-EN90
BC1A-1208
BC5H-6508-XXXX
BC1C-2803
BC3H-0038
51mm*90mm*85mm
40mm*9mm*874mm
40mm*9mm*874mm
38mm*77mm*40mm
Stanchion angle link BC4H-J113 113.5mm*77mm*40mm
50.8mm*9mm*XXXXmm
Flat bar handrail type A2 BC5H-6508-XXXX 50.8mm*9mm*XXXXmm
Link plate BC2H-0090 50mm*3mm*90mm
28mm*3mm
12mm*77mm
12mm*95.5mm
Flat head socket cap screw
M8
Accessories
Component
6799-18156933-0825
PBH2-6880PBH3-0880
6158-7812
6914-1381Washer
Screw
M8*30mm2955-0830Threaded studDome nut
Link angle 90 degree BC2A-1208
6.
9.
11
4.1
7.
4.1
4.2
7.
5.
12.
6.
9.
M8*1.25*20mm
Stud anchor Adhesive capsule anchor (HVU)
M8*80mm
M8*80mm
1.5mm*8.5mm*18mm
M8*25mm
14.28mm*6mmBC2B-0006Stanchion bush
End postType 1
1.
2.2
3.1
6.7. 9.
9.
10.
11
11
1015
13
13
13
13
14.
14.
Corner postType 3
1.1.
2.2 2.2
3.1
9.9.
9.
10.15.
10.
1111
13
13
13 133.2
13
14.
8.
13
14.
Middle postType 2
13
13
2.1
1.
3.1
9.
10.
11
15.
14.
14.14.
10.
13 13
Use with Stud anchor PBH2-6880
The Installation Procedures for Strudyna Balcony Systems A, B & C (Residential)
page 10www. strudyna.com
End postType 1
Corner postType 4
Middle postType 2
Double postType 3
NO. Name Code Size
Stanchion base (Flexible)
Assembly each post as below
Stanchion post type A (Middle)
Link adjuster
Cover plate
Stanchion angle
2.1
2.2
1.
3.1
3.2
4.
5.
6.
8.9.19.210.
12.
11.
BC3B-0008
BC1P-MD11
Stanchion post type B (End) BC2P-EN11
BC1A-1208
BC1C-2803
BC3H-0038
50mm*100mm*90mm
40mm*9mm*1,074mm
40mm*9mm*1,074mm
38mm*77mm*40mm
Stanchion angle link BC4H-J143 143.5mm*77mm*40mm
28mm*3mm
12mm*77mm
12mm*131.5mm
Flat head socket cap screw
M8
Accessories
Component
6799-18156933-0825
PBH2-6880PBH3-0880
6158-7812
6914-1381Washer
Screw
Dome nut
Link angle 90 degree BC2A-1208
5. 8.
3.1
3.2
M8*1.25*20mm
Stud anchor Adhesive capsule anchor (HVU)
M8*80mmM8*80mm
1.5mm*8.5mm*18mm
M8*25mm6933-0830 M8*30mm
7. 12mm*30mmBC3A-1208Link for double stanchion post
Use with Stud anchor PBH2-6880
Assembly Guide for Balcony System D (Commercial)
10.
10.
10.10.1.
11.
11.
11.
1.
11.
11.1.
3.1
3.13.1
2.2
8.
9.1
9.2
9.2 9.2
6.
1.
12.
12.
12.
12.
8.4.
10
12.
9.1 9.1
12.
12.11.
12.11.
12.
8. 8.
2.2
2.2
2.1
7
8.
8.
9.2
9.112.11.
Installation Guide for Strudyna Balcony System A, B & C (Residential)Tip For accurate installation, follow these 6 simple steps.
page 11www. strudyna.com
243
243
9 mm.
9 mm.
4.
1. 2. 3.
6.5.
Min 50 mm.
Ø 8 mm
Tip Use Loctite for safety.
243
Installation Guide for Strudyna Balcony System D (Commercial)Tip For accurate installation, follow these 6 simple steps.
page 12www. strudyna.com
243
243
9 mm.
9 mm.
Tip Use Loctite for Safety
4.
1. 2. 3.
6. 5.
Ø 8 mm
Min 100 cm.
243
www. strudyna.com page 13
Stanchion post
A
T
BC1P BC2P
BC1P
BC2P
type A(Middle)
type B(End)
Technical DataFlat bar material : AISI316
N/ASurface treatment : "M.F. " (Matte finished) TAP :
Order no.
BC1P-MD90
BC1P-MD11
BC2P-EN90
A (mm)
40
4040 9
BC2P-EN11 40 9
874
1074
L(mm)
874
107430
30
L1(mm)
30
30
T(mm)
9
99
9
ØD (mm)
9
96.9
6.9
ØD1(mm)
6.9
6.9
Stanchion post
L
L1
ØD ØD1
L1
Item
BC3H
Technical DataSheet material : AISI316L - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A
Order no.Item
T(mm)
A(mm)
BC3H-0038 40 3
40
L(mm)
38
113.5 3
B (mm)
77
77BC4H-J113
40 143.5 377BC4H-J143Stanchion angle
BC4H (Link)
A
T
L L
B
BC1B Order no.Item
Technical DataCasting material : AISI316 - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A
BC1B-1008
L1(mm)
90
T(mm)
8
A (mm)
51
B (mm)
30 85
H(mm)
L1
L1
T
T
B
B
H
H
A
A
Stanchion base
BC3B Order no.Item
Technical DataCasting material : AISI316 - DIN 1.4408Surface treatment : "M.F." (Matte finished)TAP : N/A
BC3B-0008 90
T(mm)
L1(mm)
100 10
A (mm)
50
B (mm)
30
H(mm)
Stanchion base
Ae)
ost
BC1A
Link adjuster
ØD
M
ØD(mm)
12
L(mm)
77
M(thread)
M8L
Order no.
BC1A-1208
Item
Technical DataBar material : AISI316Surface treatment : "M.F. " (Matte finished)TAP : N/A
L(mm)
131.595.5
ØD(mm)
1212
M (thread)
M8M8
M
L
Link angle 90 degree
BC2A Order no.
BC2A-0C08BC2A-1208
Item
Technical DataBar material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A
Order no.
BC2H-0090
A(mm)
40
T(mm)
3
L(mm)
50
T
A
L
BC2H
Link plate
Item
Technical DataSheet material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A
ML
ØD
ØD
Connector
A
T
BC1H, BC5H, BC6HBC7H, BC8H
Technical DataSheet material : AISI316
N/ASurface treatment : "M.F. " (Matte finished)TAP :
Order no.Item
L(mm)
A (mm)
BC5H-6508-XXXXBC6H-6508-XXXX
A1 A
B
C
TypeFor System
A2
BC1H-6508-XXXX B
50.850.8
50.8
50.850.8
T(mm)
9
99
99
BC7H-6508-XXXXBC8H-6508-XXXX
C1 C2
L
* Contact to Strudyna Sale team for checking the length and hole* Contact to Strudyna Sale team for more information of system D
selectselect
select
selectselect
H, BC5H, BC6HH, BC8H
Flat bar handrail
BC1C
Cover plateTechnical DataSheet material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : N/A
ØD(mm)
28
T(mm)
39
ØD1(mm)
Order no.
BC1C-2803
Item
TØD
ØD1
www. strudyna.comTAP : 27.1
page 14
Order no.
BC3A-1208
L(mm)
30
ØD (mm)
12
M (thread)
M8
ItemBC3A
Link for double stanchion postTechnical DataThreaded stud : Bar Forging material AISI316, EN 1.4401Surface treatment : Matt finishedTAP : N/A
Flat bar handrail
I316L: "M.F. : "M F : N/A
ble stanchion postble stanchion postble stanchion post: Bar Forging material
" (Matte finished)" (Ma
www. strudyna.com
Nuts & Bolts
Technical DataMaterial : AISI316 - DIN 1587
Order no.
6158-7610
M (thread)
M6M86158-7812
S.W. (mm)
1012.8
L(mm)
1215LDome nut
BNUT/DIN1587
S.W.
M
Item
Adhesive capsule for stud anchor PBH2-6880Technical DataMaterial : AISI316 - DIN 1.4401
L(mm)
M (thread)
75M8106M8LStud anchor
PBH2
PBH3
PBH1 L
M
M
Order no.
PBH1-6875PBH2-6880
PBH3-0880
Item
BT933
Technical Data Material : AISI316 - DIN 933
ØD (mm)
13
ItemOrder no.
6933-0825
6933-0830 13 30 M8
L(mm)
25
M (thread)
M8L
M
ØDScrew
TAP : 27.1
page 15
SF960
Cable Fitting
Order no.
2960-3630
Ø Cable(mm)
3
ØOD(mm)
6.35
L1(mm)
12
M(thread)
M6
L(mm)
30
EM6 deco stud cable
M
LL1
ØODItem
CX19
Order no.Size LengthItem
Ø Size (mm)
Order no.
CX19-0003-0000 3
Limit Tension(kN)
4.45
Hamma X 1x19
LOC2
Loctite 263L
ØD
Cable Lenght (mm)
select LOC2 - 6350 50 ml.
SizeTechnical DataCable material : AISI316Construction : Spiral strandConfiguration : 1x19 = 1+6+12Module of elasticity : 132 +/-10 kN/mmNote : Limit tension is calculated at 60% of MBL.
Technical DataBar material : AISI316LSurface treatment : "M.F. " (Matte finished)TAP : 57.10
BT7991 L(mm)
ØD (mm)
16 20
M (thread)
M8
Flat head socket cap screwL
M
ØD
Order no.
6799-1815
Item
Technical Data Material : AISI316 - DIN 7991
Order no. L(mm)
M (thread)
2955-0830 30M8
ItemSF955
Threaded stud
L
Ø M
Technical DataThreaded stud : Bar Forging material AISI316, EN 1.4401Surface treatment : Matt finishedTAP : N/A
AISI316 - DIN 1.4401
ded stud Data
tud : Bar Forging material
ACCESSORIES
MOCK UP BALCONY
Nuts & Bolts
T
BFWA/E1
Technical DataSheet material : AISI316Surface treatment : "E.P." (Electro polished)
Order no. T(mm)
ØD1(mm)
6914-1381 1.58.5Washer ØD
ØD1
Item
T
Order no. T(mm)
2000-2206
S.W. (mm)
105
M
S.W.
Item
Technical DataBar material : AISI316Surface treatment : "E.P. " (Electro polished)Bar material : AISI316
Right thread nut
SFNUT/R
www. strudyna.com page 16www. strudyna.com
Exclusive AgentsYear 2014
Keng Wah Hardware Co. Pte. Ltd.Blk 2 Kitchener Road #01-85Singapore 200002Tel : +(65) 6392 4896Fax : +(65) 6296 4736Email : [email protected]
Structural Dynamics Australia4 / 14 Dover Drive Burleigh Heads Queensland 4220 AustraliaTel : +07 5568 7084Fax : +07 5576 5166Email : [email protected]
Anzor Fasteners Ltd.8 Arrenway Drive Albany,Auckland, New ZealandTel : +(64) 9 476 0001Fax : +(64) 9 476 0090Email : [email protected]
Structural Dynamics Europe Limited.Unit 10 Wingate Rd. Gosport, Hampshire,UK. PO12 4DPTel : +44 (0) 845 262 5557Fax : +44 (0) 239 294 0272Email : [email protected]
TØDØD1
BC2B Order no. T(mm)
ØD1(mm)
ØD(mm)
18
M(thread)
M6
ØD(mm)
14.28BC2B-0006 68.45
Item
Stanchion bushTechnical Data Bar material : AISI316Surface treatment : Machine finished
Stainless steel 316 grade