sub pump curve catlg-60hz
TRANSCRIPT
-
8/12/2019 Sub Pump Curve Catlg-60Hz
1/69
An ISO 9001 & ISO 14001 Company
Pumping trust. Worldwide.
For specific models only.
ISO1400& 18 :0 0 22 00: 41 C00 O9 MO P
S AI N
N YA
CE ISR BTI YFIEDB
C.R.I.
SUBMERSIBLE
PUMPS
C.R.I.
SUBMERSIBLE
PUMPS60Hz60Hz
-
8/12/2019 Sub Pump Curve Catlg-60Hz
2/69
C . R . I . I S O N E A M O N Gthe few pioneers in the world to produce 100% stainless steel submersible
pumps. Having achieved a record production capacity of over one million
pumps per annum, today C.R.I. is rubbing its shoulders with the best brands
in the world, with advanced technology and safety standards as its hallmarks.
T H E B E G I N N I N Gof C.R.I., way back in 1961, was a resolute attempt to produce a few irrigation
equipments using the limited facilities of an in-house foundry.Eventually the
founder's dream was coming true as the small production unit he started keptgrowing rapidly.Now, after five eventful decades, it is an enormous, widely
reputed organization, which produces more than 1000 varieties of perfectly
engineered pumps and motors and sells its products in numerous countries
spread across 6 continents.
T H E I N F R A S T R U C T U R Eof C.R.I. is pretty comprehensive with state-of-the-art machineries and
high potential R&D wing, all within its own covered area of 150,000 square
metres. The production environment is accredited with ISO 9001 & 14001
certifications and the products are CE, UR/UL, TSE & ISI certified. The R&D
team always stays in tune with the changing scenario and seldom fails in
coming up with outstanding solutions every time.
N E E D L E S S T O S A Y ,behind this legendary growth lies the untiring, innovative, enthusiastic and
dedicated team work.And, of course, a flawlessly maintained value system
too.The name C.R.I. itself encapsulates the company's ethos: Commitment,
Reliability, Innovation.
Pumping trust. Worldwide.
-
8/12/2019 Sub Pump Curve Catlg-60Hz
3/69
C O N T E N T S
P a g e N o .
SILVER L INE SERIES
General Information
Group Performance curvesMaterials of Construction
Exploded view drawings
Performance tables and curves
Dimension and Net weight tables
04
0910
11
14
38
STAINLESS STEEL SERIES
General Information
Group Performance curves
Material of Construction
Exploded view drawing
Performance tables and curves
Dimensions and Net weight tables
41
42
44
45
50
120
TABLE CHARTS
Pipe frict ion loss table
Conversion table
128
129
Vision, Mission and Values
To be the industry leader providing best - in - class fluid management
solutions to individual and institutional customers and societies
in our chosen markets.
We will achieve this through our dedicated efforts to enhance the
welfare of all our stakeholders and by living by our values of
commitment,reliability and innovation.
-
8/12/2019 Sub Pump Curve Catlg-60Hz
4/69
G E N E R A L I N F O R M A T I O N
Pumping trust. Worldwide.
SILVER LINES E R I E SSTAINLESS STEEL & SILVER LINE SERIES
MODEL IDENTIFICATION CODE
S X X - XXX - XX (X)
NOMINAL MOTOR DIAMETER
(This digit will be applicable only when the
pump is suitable for different dia motor)
NUMBER OF STAGES
NOMINAL FLOW (US gpm)TYPE OF MATERIALS
OF CONSTRUCTION
DEEPWELL
SUBMERSIBLE PUMP
NOMINAL
PUMP DIAMETER
DEEPWELL SUBMERSIBLE PUMP
(M)
MINING APPLICATION
(This digit will be applicable only for the
pumps suitable for mining application)
4
-
8/12/2019 Sub Pump Curve Catlg-60Hz
5/69
G E N E R A L I N F O R M A T I O N
C.R.I. Submersible Pumps are the products of the expertise gained from over
five decadesofexperience, endurance and workmanship. These products are
engineered toperfectionwithutmost care and stringent quality control at all
stages to ensure a trouble free service.
Description : C.R.I. 4" Silver line series submersible pumps are built with
thermoplastic impellers, diffusers and inbulit check valve. All vital components of
these pumps are made of corrosive resistance thermoplastic and the shaft is of
SS 304/431. Pumps are multi stage centrifugal type. The optimal design of
impellers and diffusers enables the best possible hydraulic efficiency.
The pump is firmly coupled to a submersible electric motor which operates
submerged beneath the surface of water. Built in check valve prevents back flow
and reduces the risk of water hammering. All mounting dimensions of pumps &
motors are in accordance with NEMA standard.
C.R.I. Submersible pumps can be offered with either C.R.I. 'W' Series, water
filled rewindable submersible motors / C.R.I. 'R' Series, encapsulated semi wet
type submersible motor / C.R.I. "L" Series edible oil filled motors or any other
NEMA standard motors.
Features : Best operating efficiency Floating impeller design to handle sand
S.S. 304 / Ceramic top bearing Highly durable Can be easily dismantled
and repaired Can be handle more upthrust loads Wearing ring in diffuser for
long life Available M.O.C. : Type P & V.
Applications : Residential Irrigation Civil water supply Fountains
Industrial and rural water supply Fire fighting Pressure boosting units
Gardens Sprinkler systems
l l
l l l
l l
l
l l l l
l l l
l l
SILVER LINE SERIES SUBMERSIBLE PUMPS
7
7
Pumping trust. Worldwide.Pumping trust. Worldwide.
-
8/12/2019 Sub Pump Curve Catlg-60Hz
6/69
Pumped Liquids
Clean, Thin, Non-aggresive, Non explosive, Clear, Cold, Fresh Water without abrasives, Solid particles or fibre
having the following characteristics
Maximum temperature of Pumped liquid
NOMINAL DIAMETER 4(100mm)
POWER RANGE - 10 HP
SPEED 3450 rpm
3 - 120DISCHARGE
RANGE 0.7 - 27
15 - 1020TOTAL
HEADRANGE
US gpm
3m /h
ft
m 4.5 - 311
OUTLET SIZE IN INCHES 1, 1, 1 & 2
PUMP OPERATING LIMITATIONS
Motor
Minimumcooling flow
along the
motor
Vertical
installation
Horizontal
installation
minimum30angle
0.25 ft/s 91.4 33 C)F ( 91.4F (33 C)4
Performance Curve Conditions
a) The performance curves show pump performance at rated Speed(3450rpm) and voltage
b) The measurements were made with airless water at a temperature of 68F (20 C)
c) Pipe friction losses have not been included in the performance curves and charts.
d) Q/H: The curves are inclusive ofcheck valve & suction inter-connector losses at the actual speed.
e) Efficiency curve Eff% shows pump stage efficiency
f) Curves tolerance is according to ISO 9906, Annex-A
g) The performance are at rated voltage and are only indicative actual discharge depends on availability
of water in well, based on strength of water source, height of water column, submergence of pump, etc.,.
h) The given performance are for the specified materials of construction of pump.
Temperature
Permissible amount of sand
Chlorine ion density
Allowable solids
Specific gravity
Hardness (Drinking water)
Viscosity
Turbidity
pH
a)
b)
c)
d)
e)
f)
g)
h)
i)
91.4F (33 C) (max)
0.82 lb/1000 gal (max)
500 ppm (max)
3000 ppm (max)
1.004 (max)
300 ppm (max)
6 21.75 x 10m /sec (max)
50 ppm silica scale (max)
6.5 to 8.5
G E N E R A L I N F O R M A T I O N
Group Performance Curves
In view of continuous developments, the given information / descriptions / specifications / illustrations are s ubject to change without notice.
00
0 10 20 30 40 50 60 70 80 90 100 110 120
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
20 4 6 8 10 12 14 16 18 20 22 24 26
Q - (m / h)
Q - (lps)
Q - (US gpm)
0
200
400
600
800
1000
1200
1400
1600
1800
28
100
200
300
400
500
100
200
400
500
300
600
700
800
3450 rpm60 Hz
5gpm
7gpm
10gpm
15gpm
20gpm
25gpm
40gpm
50gpm
70gpm
90gpm
H-(PSI)
H-(m)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.
98
-
8/12/2019 Sub Pump Curve Catlg-60Hz
7/69
Part No. Description
Bush-LTBUp Thrust WasherSleeveStrainerSuction Inter ConnectorCable GuardCasing Top PlateDiffuser
12.0213.0313.0514.0317.0017.0417.0518.03
Part No. Description
SpacerImpellerValve HousingValve SeatValve SpringPump ShellValve BracketValve Disc
18.1219.0021.0021.0121.0221.0421.0521.06
Part No. Description
ValvePump ShaftCouplingBracketLock NutO-RingScrewWasher
21.0722.0022.0125.0332.0632.0932.1232.16
1110
18.03
19.00
25.03
19.00
18.12
18.03
14.03
21.04
32.12
17.04
32.12
13.05
22.00
22.01
32.16
17.05
21.00
21.06
21.01
21.05
21.02
21.07
12.02
32.06
13.05
13.03
32.12
32.09
25.03
12.02
18.12
12.02
17.05
19.00
25.03
17.05
12.02
17.00
21.00
32.12
21.06
21.01
21.05
21.02
21.07
12.02
32.06
13.05
13.03
18.03
19.00
12.02
12.02
22.00
17.00
14.03
32.12
17.04
32.12
13.05
21.04
22.01
19.00
19.00
19.00
32.16
17.05
18.03
32.16
17.05
25.03
32.16
17.05
18.03
18.12
17.05
25.03
18.12
32.09
25.03
G E N E R A L I N F O R M A T I O N
Exploded Views
S4P (5 - 25 gpm) S4V (5 - 25 gpm)
Note: Type - V is available only for specific models upto 1 outlet size.
Delrin is the registered trademark of Dupont. *Noryl, ** Lexan is the registered trademark of GE plastics.
NOMINAL DIA. 4
PART NAME
CHECK VALVE HOUSING
CHECK VALVE
CHECK VALVE SEAT
OUTER SHELL
IMPELLER
DIFFUSER CHAMBER
STOP RING
TYPE - VTYPE - P
SS - 304
DELRIN
NBR
INTERMEDIATE BEARING
(SLEEVE / BUSH)
SS - 304 / NBR/BRONZE
SUCTION INTER CONNECTOR SS - 304
PUMP SHAFT HEXAGONAL SS - 304
SS - 304
LEXAN** / NORYL
SS - 304
CABLE GUARD SS - 304
COUPLING SS - 329
INLET SCREEN
NORYL* / DELRIN
Nylon-6(Polyamide)
DELRIN
NBR
SS - 304
LEXAN**
SS - 304
SS - 304 / NBR
Nylon-6(Polyamide)
SS - 304
SS - 304
SS - 329
SS - 304SS - 304
NORYL* / DELRIN /LEXAN**
Materials of Construction
I n v ie w o f con ti nu ou s d evel op me nt s, th e g iven i nf or ma ti on / d escr ip ti on s / spe ci fi ca ti on s / i ll us tr at io ns a re sub je ct to cha ng e w it ho ut no ti ce . A ll mo un ti ng d imen si on s a re i n a ccor da nce w it h N EMA S ta nd ar ds .
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
-
8/12/2019 Sub Pump Curve Catlg-60Hz
8/69
Exploded View - S4P (40 gpm) Exploded Views
Part No. Description
Bush-LTBUp Thrust WasherSleeveStrainerSuction Inter ConnectorCable GuardThrust PadDiffuserWearing Ring
12.0213.0313.0514.0317.0017.0411.0418.0317.01
Part No. Description
SpacerImpellerValve HousingValve SeatValve SpringPump ShellValve BracketValve DiscChamber Cover
18.1219.0021.0021.0121.0221.0421.0521.0618.04
Part No. Description
ValvePump ShaftCouplingBracketLock NutO-RingScrewWasherSuction Inter Connector Plate
21.0722.0022.0125.0332.0632.0932.1232.1617.02
Part No. DescriptionBush-LTBSleeveStrainerSuction Inter ConnectorCable GuardDiffuserChamber Cover
12.0213.0514.0317.0017.0418.0318.04
Part No. Description Part No. DescriptionImpellerValve HousingValve SeatValve SpringPump ShellValve BracketValve Disc
19.0021.0021.0121.0221.0421.0521.06
ValvePump ShaftCouplingBracketLock NutO-RingScrewWasher
21.0722.0022.0125.0332.0632.0932.1232.16
S4P (50 & 70* gpm) S4P (90 gpm)
18.03
11.04
19.00
17.01
18.04
13.05
18.03
11.04
19.00
17.01
18.04
13.05
18.03
11.04
19.00
17.01
18.04
18.03
11.04
19.00
17.01
18.04
32.12
17.04
32.12
21.04
22.00
17.02
14.03
17.00
13.05
17.02
22.01
21.00
21.06
32.09
25.03
12.02
32.06
13.05
32.16
13.05
18.03
11.04
19.00
17.01
18.04
13.05
21.00
32.12
21.06
21.01
21.05
21.02
21.07
12.02
32.06
13.0513.03
18.03
19.00
18.12
18.03
19.00
18.12
19.00
17.02
14.03
17.00
21.04
32.12
17.04
32.12
13.05
22.00
22.01
32.09
25.03
18.03
22.01
32.12
19.00
18.04
18.03
19.00
18.04
18.03
19.00
18.04
13.05
25.03
12.02
13.05
14.03
21.00
32.12
21.06
21.01
21.05
21.02
21.07
32.09
25.03
12.02
32.06
13.05
32.16
18.03
19.00
18.04
18.03
19.00
18.04
18.03
19.00
13.05
25.03
12.02
18.03
18.04
17.00
22.00
21.04
17.04
32.12
G E N E R A L I N F O R M A T I O N
All mounting dimensions are in accordance with NEMA Standards. * For 70 gpm internal NRV is not provided.
All mounting dimensions are in accordance with NEMA Standards.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
1312
-
8/12/2019 Sub Pump Curve Catlg-60Hz
9/69
Per formance Table
Nominal Diameter : 4" Nominal Flow : 5 gpm Outlet Size : 1" NPT
Per fo rm anc e Curves
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.
Nominal Diameter : 4" Nominal Flow : 5 gpm Outlet Size : 1" NPT
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4V-5-11
PUMPMODEL
HP
1/2
PSI
0 8.8 8.5 7.9 7.6 7.1 6.7 6.1 5 .5 4.8 3.5
20 8.7 8.2 7.9 7.5 6.9 6.4 5.9 5.4 4.0
30 8.6 8.1 7.8 7.4 6.8 6.3 5.8 5.3 3.9
40 9.0 8.5 8.0 7.7 7.3 6.7 6.2 5.7 5.2 3.8
50 8.6 8.0 7.7 7.2 6.8 6.3 5.8 5.3 3.9
60 7.8 7.5 7.0 6.6 6.0 5.4 4.7
70 6.9 6.4 5.8 5.2 4.1
80 5.8 5.3 3.9
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
146 13 7 12 9 12 0 11 10 3 9 4 85 7 7 68 59 5 1 42 33 25 1 6
S4P-5-11
155
HP
Shut Off - PSI
S4P- 5-153/4
S4V- 5-15
212
PSI
0 9.0 8.7 8.3 8.0 7.7 7.5 7 .1 6.9 6.5 6.1 5.7 4.5
20 8.9 8.5 8.1 7.9 7.6 7.4 7.0 6.8 6.4 6.0 5.6 5.1 4.6
30 8.9 7.4 8.0 7.9 7.6 7.3 7.0 6.7 6.3 5.9 5.5 5.1 4.5
40 8.9 8.4 8.0 7.9 7.6 7.3 7.0 6.7 6.3 5.9 5.5 5.1 4.5
50 8.8 8.3 7.9 7.8 7.6 7.2 6.9 6.6 6.2 5.8 5.4 5.0
60 8.6 8.3 7.9 7.9 7.6 7.4 7.0 6.8 6.4 6.0 5.6 5.3 4.6
70 7.9 7.6 7.3 7.0 6.7 6.3 5.9 5.5 5.3 4.5
80 7.2 6.9 6.5 6.1 5.7 5.1 4.8
4 0 6 0 8 0 1 00 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0 2 2 0 2 4 0 2 6 0 2 8 0 3 0 0 3 20 3 40 3 60 3 80 4 00 4 50
1 94 1 86 1 7 7 16 8 16 0 15 1 14 2 1 34 1 25 1 1 6 10 8 9 9 9 0 8 2 7 3 6 5 5 6 4 7 3 9 1 7
HP
Shut Off - PSI
S4P-5-191
S4V-5-19
268
40 60 80 100 120 140 160 180 200 220 240 260 280 300 350 400 450 500 550 600
250 241 232 224 215 206 198 189 181 172 163 155 146 137 116 94 72 51 29 7
PSI
0 8.7 8.6 8.3 8.2 7.6 7.0 6.3 5.5 4.4
20 9.0 8 .6 8.5 8 .2 8 .1 7 .9 7 .6 7 .0 6.3 5 .6 4 .5
30 9.0 8.6 8.5 8.2 8.1 7.9 7.6 7.4 6.8 5.8 4.9
40 8.9 8.6 8.5 8.2 8.1 7.9 7.6 7.4 7.0 6.3 5.6 4.6
50 8.9 8.6 8.4 8.2 8.1 7.9 7.6 7.4 7.0 6.8 6.0 4.9
60 9.0 8.6 8.5 8.2 8.1 7.9 7.7 7.4 7.1 6.9 6.7 6.3 6.1 5.7 4.6
70 8.5 8.2 8.1 7.9 7.6 7.4 7.0 6.8 6.6 6.3 5.8 5.5 5.2 4.6
80 8.0 7.8 7.5 7.3 7.0 6.8 6.5 6.2 5.8 5.5 4.9 4.5
S I L V E R L I N E S E R I E S
In view of continuous developments, the given information / descriptions / specifications / illustrations are s ubject to change without notice.
S4P-560Hz
3450 rpm
2.01.801.601.401.201.00.800.600.40
180
140
100
60
20
550
450
350
250
150
50
Q - (m /h)
Q - (US gpm)
Q - (lps)
0
0
0.20
0.05 0.1 0.30.15 0.2 0.25 0.35 0.4 0.45 0.5 0.55 0.6
9876543210
120
40
80
160
0 0
100
200
300
400
500
600
0
40
80
120
160
200
240
S4P-5-11(HP)*
S4P-5-15(HP)*
H-(m)
H-(PSI)
H-(ft)
S4P-5-19(1HP)*
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
1514
-
8/12/2019 Sub Pump Curve Catlg-60Hz
10/69
Per formance Table Per fo rm anc e Curves
Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT
Shut Off - PSI
S4P-7-133/4
PSI
0 11.5 11.0 10.7 10.1 9.6 9.2 8.7 8.1 7.5 6.4 5.7 5.0
20 11.4 1 0.9 10.6 1 0.0 9.5 9.1 8.6 8.0 47.3 6.3 5.5
30 11.4 10.9 1 0.5 10.0 9.5 9.1 8.6 8.0 7.1 6.3 5.5
40 11.3 10.8 10.4 9.9 9.4 9.0 8.5 7.8 7.0 6.2 5.4
50 11.3 10.8 10.4 9.9 9.4 9.0 8.5 7.8 6.8 6.2 5.4
60 11.5 11.2 10.7 10.6 9.8 9.3 8.4 8.1 7.5 6.6 6.1 5.3
70 11.2 10.7 10.3 9.8 9.3 8.4 8.1 7.5 6.5 6.1 5.3
80 10.6 10.2 9.8 9.3 8.4 8.0 7.4 6.5 6.0
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
1 74 1 66 1 57 1 48 1 40 1 31 1 23 1 14 1 05 9 7 8 8 4 9 7 1 6 2 5 3 4 5 3 6 2 7 1 9 1 0
HP
S4V-7-13
183
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-7-10
PUMPMODEL
HP
1/2
PSI
0 11.5 10.2 9.6 8.8 8.3 7.2 5.9 4 .9
20 11.3 10.0 9.6 8.6 8.1 6.9 5.6 4.9
30 11.3 1 0.0 9.6 8.5 8.1 6.9 5.4 4.9
40 11.3 1 0.0 9.6 8.5 8.0 6.9 5.2
50 11.2 9.9 9.5 8.3 7.9 6.8 5.2
60 11.2 9.9 9.4 8.3 7.9 6.8 5.0
70 11.0 9.8 9.3 8.2 7.8 6.7 4.9
80 9.7 9.2 8.0 7.8 6.7 4.8
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
13 4 12 5 11 6 10 8 99 9 0 8 2 73 6 5 56 4 7 3 9 30 21 13
S4V-7-10
143
Shut Off - PSI
S4P-7-171
HP
S4V-7-17
226
PSI
0 11.5 11.3 10.9 10.6 10.3 10.0 9 .6 9.2 8.7 8.2 7.6 7.0 5.6
20 11.4 11.2 10.8 10.5 10.2 9 .9 9.5 9.1 8.6 8.0 7.5 6.9 6.3 5.7
30 11.3 11.1 10.7 10.5 10.2 9.8 9.4 9.0 8.5 7.9 7.3 6.9 6.3 5.6
40 11.4 11.1 10.7 1 0.5 1 0.2 9.8 9.4 8.9 8.5 7.9 7.3 6.8 6.2
50 11.4 1 1.0 1 0.7 1 0.4 1 0.1 9.7 9.6 8.9 8.4 7.8 7.2 6.7 6.1
6 0 11. 3 10. 9 10. 6 10. 3 10 .0 9 .6 9 .2 8 .7 8.2 7 .6 7. 0 6.6 6. 1
7 0 1 1. 2 1 0. 9 1 0. 6 1 0. 3 1 0. 0 9 .6 9 .2 8 .7 8 .2 7 .6 7 .0 6 .4 5 .9
8 0 10 .8 1 0. 5 10. 2 9 .9 9.5 9. 1 8 .6 8 .1 7 .5 6.9 6 .3 5. 7
40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 450 500 550 600 650
209 200 192 183 174 166 157 14 140 131 123 114 105 97 88 79 71 62 53 32
Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT
S I L V E R L I N E S E R I E S
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are s ubject to change without notice.
400
350
300
250
200
150
100
50
280
260
900
0.6250.3750.125
2.51 1.50.5
0.75
240
220
700
800
200
180600
12119
2
8
0.5
765 10
160
140
500
120
100
300
400
80
60 200
40
20
100
43210
0
00
0 0.25
Q - (lps)
Q - (US gpm)
Q - (m /h)
S4P-760Hz
3450 rpm
S4P-7-10(HP)*
S4P-7-13(HP)*
S4P-7-17(1HP)*
H-(m)
H-(PSI)
H-(ft)
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
1716
-
8/12/2019 Sub Pump Curve Catlg-60Hz
11/69
Per formance Table Per fo rm anc e Curves
Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient PerformancePUMPMODEL
HP
Shut Off - PSI
S4 P - 7 - 21 1
299
0 11.5 11.1 10.8 10.4 10.1 9.1 8.0 6 .9 5.1
20 11.4 11.1 10.7 10.3 10.1 9.6 9.0 8.0 6 .9 5.1
30 11.4 11.1 10.7 10.3 10.0 9.5 9.1 8.7 7.6 6.0
40 11.3 11.0 10.6 10.2 10.0 9 .5 9.1 8.6 7.9 7.0 5.2
50 11.2 10.9 10.6 10.2 9 .9 9.4 9.0 8.6 8.0 7.6 6.0
60 11.4 10.8 10.4 10.1 9 .9 9.3 8.9 8.6 8.0 7.6 7.1 5.2
70 11.4 1 1.1 1 0.8 1 0.4 1 0.1 9.6 9.3 8.8 8.5 8.0 7.5 7.0 6.0
8 0 1 1.4 1 1.0 1 0.8 1 0.3 1 0. 0 9 .6 9 .3 8. 8 8 .5 7 .9 7.5 7 .0 6.0 5 .3
120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580
247 238 229 221 212 203 195 186 177 169 160 152 143 134 126 104 82 61 39 17
HP
Shut Off - PSI
S 4P - 7 - 2 8 2
372
PSI
0 11.5 11.3 11 9 .8 9.2 8.9 8.1 7.3 6 .4 5.3 4
20 11.5 11.3 1 1 10.7 9.8 9 .2 8.9 8.1 7.2 6 .4 5.2 4
30 11.5 11.3 11.2 11.0 10.7 10.4 10.0 9 .5 8.7 7.8 6.9 5.9 5.0 3.4
40 11.5 11.3 11.2 11.0 10.7 10.4 9.9 9.2 8.9 8.1 7.2 6.4 5.2 4.0
50 11.5 1 1.3 1 1.0 10.8 1 0.6 10.1 9.9 9.2 9.5 8.7 7.8 6.9 6.0 5.0
60 11.5 1 1.3 1 1.0 1 0.8 1 0.6 1 0.1 9.8 9.2 9.5 8.8 8.1 7.2 6.4 5.2
7 0 1 1.5 1 1.2 1 1.0 1 0.8 1 0. 5 10 .1 9 .9 9. 7 9 .4 8 .9 8.7 7 .8 6.9 6 .0
8 0 1 1. 5 1 1. 2 1 1. 0 1 0. 8 1 0. 5 1 0. 1 9 .9 9 .7 9 .4 8 .9 8 .7 8 .1 7 .2 6 .4
160 200 220 240 260 280 300 320 340 360 380 400 450 500 550 600 650 700 750 800 850 900 950 1000
312 294 286 277 268 260 251 242 234 225 216 208 186 165 143 121 100 78 56 35
HP
Shut Off - PSI
S4P - 7 - 26 2
345
PSI
0 11.5 11.3 10.9 10.5 9.9 9.1 8 .4 7 .5 6 .5 5.4 3 .8
20 11.4 11.0 10.9 10.6 10.2 9 .9 9.0 8.0 7.0 6.1 5.3 3.8
30 11.4 11.0 10.9 10.6 10.2 9 .9 9.5 8.7 8.1 7.7 6.0 4.8
40 11.4 11.1 10.9 10.6 10.2 9.9 9.5 9.1 8.4 7.5 6.1 5.4
50 11.5 11.1 10.9 10.5 0.2 9.9 9.5 9.1 8.9 8.1 7.2 5.8 4.8
60 11.5 1 1.2 1 0.8 1 0.5 1 0.1 9.8 9.5 9.1 8.8 8.4 7.5 6.5 5.4
7 0 1 1.4 1 0.9 1 0.6 1 0.4 1 0. 1 9 .8 9 .5 9. 1 9 .0 8 .7 6.3 7 .2 5.8 4 .7
8 0 1 1. 4 1 0. 9 1 0. 6 1 0. 4 1 0. 1 9 .8 9 .5 9 .1 9 .0 8 .8 8 .3 7 .5 6 .5 5 .4
160 200 220 240 260 280 300 320 340 360 380 400 450 500 550 600 650 700 750 800 850 900 950 1000
288 271 262 253 245 236 227 219 210 201 193 184 162 141 119 97 76 54 32
400
350
300
250
200
150
100
50
280
260
900
0.6250.3750.125
2.51 1.50.5
0.75
240
220
700
800
200
180600
12119
2
8
0.5
765 10
160
140
500
120
100
300
400
80
60 200
40
20
100
43210
0
00
0 0.25
Q - (lps)
Q - (US gpm)
Q - (m /h)
S4P-760Hz
3450 rpm
S4P-7-21(1 HP)
S4P-7-26 (2 HP)
S4P-7-28 (2 HP)H-(m)
H-(PSI)
H-(ft)
S I L V E R L I N E S E R I E S
PSI
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are s ubject to change without notice.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
1918
-
8/12/2019 Sub Pump Curve Catlg-60Hz
12/69
Per formance Table Per fo rm anc e Curves
Nominal Diameter : 4" Nominal Flow : 10 gpm Outlet Size : 1" NPT Nominal Diameter : 4" Nominal Flow : 10 gpm Outlet Size : 1" NPT
0 16.0 15.5 14.9 1 4.4 1 3.9 1 2.6 11.9 1 1.6 10.6 9.8 8.5 7.7
20 15.8 15.2 14.6 14.2 13.3 12.3 11.6 10.9 10.2 9.2 8.1
30 15.5 14.9 14.4 13.9 12.6 11.9 11.3 10.6 9.8 8.5 7.7
40 15 .5 1 4.9 1 4.4 1 3.9 12 .6 1 1. 9 11. 3 10 .6 9.8 8.550 14 .2 1 3.3 1 2.3 1 1.6 10 .9 1 0. 2 9.2 8. 160 11.9 11.3 10.6 9.8 8.5 7.7
2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 10 1 20 1 30 1 4 0 1 50 1 60 1 7 0 18 0 19 0 20 0 2 10
95 91 87 82 78 74 69 65 61 56 5 2 4 8 43 39 35 30 26 22 17 13
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-10-06
PUMPMODEL
HP
1/2
104
PSI
S4V-10-06
Shut Off - PSI
S4P-10-08
139
3/4S4V-10-08
PSI
0 15.8 14.8 14.0 1 2.7 11.6 10.6 9.2 7.820 15.6 14.6 13.7 12.4 11.4 10.6 8.9 7.030 15.6 14.6 13.7 12.4 11.4 10.3 8.9 7.0
40 15.3 14.4 13.4 12.2 11.1 9.9 8.5 7.0
50 15.0 14.2 13.1 11.9 10.9 9.8 8.4
60 14 .8 1 4.0 1 2.7 1 1.6 10 .7 9.6 8.4
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 2 0 3 4 0 3 60 3 8 0 4 0 0
130 12 1 11 3 10 4 95 8 7 7 8 6 9 6 1 5 2 4 3 3 5 26 17
Shut Off - PSI
S4P-10-10
174
PSI
0 15.9 1 5.1 14.2 13.6 1 2.9 1 1.9 1 0.9 9.9 9.1 8.0 6.0
20 15.7 14.9 14.0 13.4 12.7 1 1.7 10.7 9.7 8.8 7.5
30 15.5 14.7 13.9 13.2 12.4 11.4 1 0.4 9.5 8.6 7.0
40 15.9 15.5 14.7 13.9 13.2 12.4 11.4 10.4 9.5 8.6 7.0
50 15.9 15.4 14.6 13.8 13.1 12.3 11.3 10.3 9.4 8.5 6.960 15 .9 1 5.1 1 4.2 1 3.6 12 .9 1 1. 9 10. 9 9. 9 9.1 8.0 6 .0
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 2 0 3 4 0 3 60 3 8 0 4 0 0
1 65 1 57 1 48 1 39 1 31 1 22 1 13 1 05 9 6 8 7 7 9 7 0 6 1 5 3 4 4 3 5 2 7 1 8
1S4V-10-10
Shut Off - PSI
S4P-10-14
245
PSI
0 16.2 15.8 15.3 14.9 1 4.5 13.7 13.3 12.8 12.2 11.5 10.8 8.9 7.020 16.1 15.7 15.2 14.8 14.3 13.6 13.2 12.7 12.0 11.3 10.6 9.9 8.9 6.9
30 16.0 15.6 15.1 14.7 14.1 13.6 13.1 12.6 12.0 11.3 10.6 9.8 8.9 8.3
40 15.5 15.1 14.5 14.1 13.6 13.1 12.6 12.0 11.1 10.5 9.6 8.8 8.2
50 15.9 15.4 15.0 14.3 14.0 13.3 12.8 12.2 11.5 11.0 10.4 9.5 8.7 8.160 15 .8 1 5.3 1 4.9 1 4.5 1 37 1 3. 3 12. 8 12 .2 1 1. 5 1 0. 8 1 0.3 9.4 8 .6 8 .0 7 .0
8 0 1 00 1 20 1 40 1 6 0 1 80 2 00 2 20 2 40 2 60 2 8 0 3 0 0 3 20 3 40 3 60 3 80 4 00 4 50 5 00 5 50
2 10 2 0 1 1 93 1 8 4 17 5 1 67 1 5 8 1 49 1 4 1 1 3 2 12 3 1 15 1 0 6 9 7 8 9 8 0 7 1 5 0 2 8
1S4V-10-14
Shut Off - PSI
S4P-10-17
292
2
PSI
0 16.0 15.5 15.2 14.8 1 4.4 14.0 13.5 13.0 12.5 12.0 11.3 9.8 7.8
20 15.9 15.4 15.1 14.7 14.1 13.9 13.4 12.9 12.4 11.8 11.2 10.6 9.7 7.9
30 15.8 15.3 15.0 14.6 14.2 13.8 13.3 12.8 12.3 11.7 11.1 10.5 9.6 9.1 6.8
40 15.8 15.3 15.0 14.6 14.2 13.8 13.2 12.7 12.2 11.6 11.0 10.4 9.8 9.0 8.0
50 16 .1 1 5.5 1 5.2 1 4.8 14 .4 1 4. 0 13. 5 13 .0 1 2. 5 1 2. 0 1 1.3 1 0.3 9 .5 9 .3 8 .9
60 15 .5 1 5.2 1 4.8 1 4.4 14 .0 1 3. 5 13. 0 12 .5 1 2. 0 1 1. 3 1 0.3 9.5 9 .2 8 .8 8 .0
1 80 2 00 2 20 2 40 2 6 0 2 80 3 00 3 20 3 40 3 60 3 8 0 4 0 0 4 20 4 40 4 60 4 80 5 00 5 50 6 00 6 50
2 14 2 0 5 1 9 7 1 88 1 7 9 1 71 1 6 2 1 53 1 4 5 1 36 1 2 7 1 19 1 10 1 0 1 9 3 8 4 7 5 5 4 3 2
Shut Off - PSI
S4P-10-24
419
3
PSI
0 160 15.7 15.3 15.1 1 4.9 14.7 14.0 1 3.2 12.4 1 1.5 1 0.3 9.1 7.3
20 15.9 15.6 15.3 15.0 14.9 1 4.7 14.4 13.9 13.1 12.3 11.4 10.2 9.0 7.2
30 15.8 15.5 15.2 15.0 14.8 14.6 14.4 14.0 13.7 12.8 12.2 10.5 9.6 8.4
40 15.7 15.5 15.2 1 4.69 14.8 14.5 14.3 14.0 13.7 13.2 12.4 11.4 10.3 9.2 7.4
50 15.6 15.4 15.1 14.9 14.7 14.4 14.2 13.9 13.6 13.2 12.8 12.2 10.5 9.6 8.4
60 16 .0 1 5.7 1 5.3 1 5.1 14 .9 1 4. 7 14. 3 14 .1 1 3. 9 1 3. 6 1 3.2 1 2.8 12 .4 11 .4 1 0.3 9. 2 7 .4
2 60 2 80 3 00 3 20 3 4 0 3 60 3 80 4 00 4 20 4 40 4 6 0 4 8 0 5 00 5 50 6 00 6 50 7 00 7 50 8 00 8 50
3 .6 2 98 2 89 2 81 2 7 2 2 6 3 2 5 5 2 4 6 2 3 7 2 29 2 2 0 2 1 1 2 0 3 1 8 1 1 5 9 1 3 8 1 16 9 4 7 3
S4P-1060Hz
3450 rpm
16141210864
Q - (m /h)
Q - (US gpm)
Q - (lps)0.9
3.3 3.6
3001000
240
270
800
210
600
700
900
0.750.45 0.6
150500
90
120 400
300
0.30.15
60 200
0
0
30
0
100
3.02.4 2.71.8 2.11.50.9
2
0.3 0.60
0
1.2
180
1.05
0
50
100
150
200
250
300
350
400
450
S4P-10-06(HP)*
S4P-10-08(HP)*
S4P-10-10(1HP)*
S4P-10-14(1HP)*
S4P-10-17(2HP)
S4P-10-24(3HP)H-(m)
H-(PSI)
H-(ft)
S I L V E R L I N E S E R I E S
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are s ubject to change without notice.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
2120
-
8/12/2019 Sub Pump Curve Catlg-60Hz
13/69
Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 15 gpm Outlet Size : 1" NPTDiameter Nominal : 4" Nominal Flow : 15 gpm Outlet Size : 1" NPTDiameter
Per formance TableDepth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-15-05
PUMPMODEL
HP
1/2
77
PSI
0 24 23.2 21.4 20.8 20.1 19.1 17.7 16.4 15.3 14.1 10.9
2 0 23 .6 22 .3 21 .1 20 .5 1 9. 6 1 8.4 1 7 15. 9 1 4.7 12 .5 10 .8
3 0 2 0. 8 2 0. 1 1 9. 1 1 7. 7 1 6. 4 1 5. 3 1 4. 1 1 0. 9
4 0 1 9. 1 1 7. 7 1 6. 4 1 5. 3 1 4. 1 1 0. 9
1 5. 9 1 5. 9 1 4. 7 1 2. 5 1 0. 8
1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 10 1 2 0 1 30 1 4 0 15 0 16 0 1 70 1 80 1 90 2 0 0
72 68 64 59 55 51 46 42
S4V-15-05
Shut Off - PSI
S4P-15-073/4
PSI
0 24 23.4 22.8 22.1 21.4 20.4 19.7 18.9 17.9 17.2 16.4 15.4 14.6 13.3 11.3 9.3
20 23.7 21.1 22.5 21.8 20.9 20 19.3 18.4 17.6 16.8 15.9 15 14 12.3 10.3
3 0 2 2. 1 2 1. 4 2 0. 4 1 9. 7 1 8. 9 1 7. 9 1 7. 2 1 6. 4 1 5. 4 1 4. 6 1 3. 3 1 1. 3 9 .3
4 0 2 0. 4 1 8. 7 1 8. 9 1 7. 9 1 7. 2 1 6. 4 1 5. 4 1 4. 6 1 3. 3 1 1. 3 9 .3
50 18.4 17.6 16.8 15.9 15 15 12.3 10.3
6 0 16 .4 15 .4 14 .6 13 .3 1 1. 3 9 .3
3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00 1 1 0 1 20 1 3 0 1 40 1 5 0 1 60 1 70 1 8 0 1 90 2 0 0 2 10 2 20
96 91 87 83 78 74 70 65 61 57 52 48 44 39 35 31 26 22 18 1 3
S4V-15-07
109
Shut Off - PSI
S4P-15-091
S4V-15-09
140
Shut Off - PSI
S4P-15-121
S4V-15-12
186
PSI
0 23.5 2 2.8 22 20.7 19.7 19 18.3 17 15.9 1 4.4 1 3.5 12 9.1
20 23.4 22.6 21.8 20.5 19.5 18.8 18.2 16.8 15.7 14.2 13.3 11.7
30 23.2 22.4 21.4 20.2 19.4 18.7 17.7 16.5 15.2 13.9 12.8 10.6
40 23.2 22.4 21.4 20.2 19.4 18.7 17.7 16.5 15.2 13.9 12.8 10.6
5 0 23 .1 22 .2 21 .1 2 0. 1 1 9.2 1 8.5 17. 5 1 6.3 15 .0 13 .8 12 .6 10 .5
60 22.8 22 20.7 19.7 19 18.3 17 15.9 14.4 13.5 12 9.1
70 22 20.7 19.7 19 18.3 17 15.9 14.4 13.5 12 9.1
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 40 2 60 2 80 3 0 0 3 2 0 3 40 3 6 0 3 8 0 4 0 0
1 77 1 68 1 59 1 51 1 42 1 33 1 25 1 16 1 07 9 9 9 0 8 1 7 3 6 4 5 5 4 7 3 8 2 9 2 1 1 2
Shut Off - PSI
S4P-15-15 2
239
PSI
0 22.2 2 1.7 21.2 20.3 19.6 19 18.4 1 7.7 16.8 16 15.1 13.8 12.7 11
2 0 2 2. 1 2 1. 6 2 1 2 0. 1 1 9 .5 1 8. 9 1 8 .2 1 7. 5 1 6 .5 1 5. 8 1 4 .8 1 3. 5 1 2 .3 1 0. 5
3 0 2 1. 6 2 1 2 0. 1 1 9. 5 1 8 .9 1 8. 2 1 7 .5 1 6. 5 1 5 .8 1 4. 8 1 3 .5 1 2. 3 1 0 .5
4 0 2 1. 5 2 0 .8 1 9. 9 1 9. 3 1 8. 7 1 8 1 7. 3 1 6 .4 1 5. 6 1 4 .5 1 3. 3 1 1 .9 1 0
5 0 2 0. 1 1 9. 5 1 8 .9 1 8. 3 1 7 .6 1 6. 7 1 5. 9 1 5 1 3. 7 1 2. 6 1 0 .8
6 0 1 9.6 19 1 8.4 17 .7 16 .8 16 1 5.1 13 .8 12 .7 11
7 0 1 9 18 .4 1 7.7 16 .8 16 15 .1 1 3.8 12 .7 11
140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 550
1 78 1 6 9 16 1 1 52 1 43 1 3 5 1 26 1 1 7 10 9 1 00 9 1 8 3 7 4 6 5 5 7 4 8 3 9
Shut Off - PSI
S4P-15-22 3
349
PSI
0 24.0 22.5 21.8 20.0 19.0 16.5 14.0 12.0 9.0
20 24.0 2 2.5 2 2.0 20.0 1 9.0 16.5 1 4.0 12.0 9.0
30 23.0 2 2.0 2 0.6 19.0 1 7.5 15.7 1 3.4 10.5 7.5
40 24.0 2 2.4 2 1.5 2 0.1 1 8.9 1 6.4 13.9 1 1.9 9.0
50 24.0 2 3.0 22.0 21.1 19.1 17.5 15.7 1 3.4 10.5
60 24.0 23.0 2 2.3 21.5 20.1 18.8 16.4 14.2 12.0 9.0
7 0 2 3. 9 2 3. 0 2 2. 4 2 1. 9 2 1 .0 1 9. 5 1 7 .4 1 5. 7 1 3 .4 1 0. 5
8 0 2 3. 8 2 3. 0 2 2 .5 2 1. 9 2 1 .4 2 0. 1 1 8. 9 1 6. 3 1 3. 9 1 1. 8 9 .1
120 140 160 180 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950
286 277 268 260 251 229 208 186 165 143 121 100 78 56 35
PSI
0 24 22.9 21.8 20.1 19 17.8 16.5 14.9 13.2 10.6
20 23.6 22.4 21.2 19.8 15.6 17.3 16 14.5 12.6
30 23.5 22.3 21 19.6 18.4 17.2 15.7 14 11.9
40 23.5 22.3 21 19.6 18.4 17.2 15.7 14 11.9
5 0 21 .8 20 .2 19 .1 17 .9 1 6. 6 15 1 3.3 10. 7
6 0 20 .1 19 17 .8 16 .5 1 4. 9 1 3.2 1 0.6
7 0 19 17 .8 16 .5 14 .9 1 3. 2 1 0.6
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 40 2 60 2 80 3 0 0 3 2 0 3 40 3 6 0 3 8 0 4 0 0
1 31 122 1 13 1 05 9 6 87 79 7 0 6 1 53 44 35 2 7 1 8
S I L V E R L I N E S E R I E S
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
350
300
250
200
150
100
50
Q - (lps)
1.50
5.44.84.2
1.20
3
0.90
6
2.4
0.60
8
3.6
104
1.8
2
0.6 1.2
0.30
40
100
0
0
0
00
80
120
160
200
240
200
300
400
500
600
700
800
6
Q - (US gpm)
Q - (m /h)
S4P-1560Hz
3450 rpm
S4P-15-05 (HP)*
S4P-15-12 (1HP)*
S4P-15-15 (2HP)
S4P-15-22(3HP)
12 14 16 18 20 22 24 26
H-(m)
H-(PSI)
H-(ft)
S4P-15-09 (1HP)*
S4P-15-07 (HP)*
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
2322
-
8/12/2019 Sub Pump Curve Catlg-60Hz
14/69
Nominal : 4" Nominal Flow : 20 gpm Outlet Size : 1" NPTDiameter
Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 20 gpm Oultlet Size : 1" NPTDiameter
Per formance Table
Shut Off - PSI
S 4P - 2 0 - 28 5
Shut Off - PSI
S 4P - 2 0 - 17 3
Shut Off - PSI
S4P-20-122
Shut Off - PSI
S4P-20-091
Shut Off - PSI
S4P-20-071
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-20-5
PUMPMODEL
HP
3/4
PSI
S4V-20-5
S4V-20-07
S4V-20-09
S4V-20-12
77
112
138
199
277
447
0 30 27 24 20 16 10
20 27 26 23 18 15 10
30 26 22 18 15 7
40 22 18 14
50 18 12
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
70 61 52 44 35 26 18 9
PSI
0 29 27 25 23 21 18 14 8
20 28 26 24 23 20 16 13.5 6.5
30 28 26 24 22 19 16 12 6
40 28 26 24 22 19 15 11.5 6
50 26 24 21 18 15 10
60 23 21 18 14 8.5
70 21 17 14 8
80 17 14 7
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
105 9 7 88 79 70 62 53 44 36 27 18 10
PSI
0 30 28 27 25 23 21 19 17 14 9
20 29 28 26 25 23 20 18 15 11 7
30 29 28 26 24 22 20 18 15 11
40 29 27 26 24 22 20 18 15 11
50 29 27 26 24 22 20 17 14 9
60 27 25 24 21 19 17 14 9
70 25 23 21 19 16 13 9
80 23 21 18 16 13
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
1 30 12 2 11 3 10 4 96 8 7 7 8 70 6 1 52 44 35 20 18 9
PSI
0 29.8 2 8.7 27.5 26.6 25.6 24.5 23.4 2 2.2 20.9 17.8 17.3 15.5 13.8
20 29.5 28.4 27.3 26.4 25.3 24.2 23.2 21.9 20.1 17.7 16.9 15.1
30 29.3 28.1 27 26.1 25 24 22.8 21.6 19.4 17.6 1 6.7 15
40 29.3 28.1 27 26.1 25 24 22.8 21.6 19.4 17.6 16.7 15
50 29.3 28.1 27 26.1 25 24 22.8 21.6 19.4 17.6 16.7 15
6 0 2 9. 8 2 8. 7 2 7. 5 2 6. 6 2 5. 6 2 4. 5 2 3. 4 2 2. 2 2 0. 9 1 7. 8 1 7. 3 1 5. 5 1 3. 8
7 0 2 8. 7 2 7. 5 2 6. 6 2 5. 6 2 4. 5 2 3. 4 2 2. 2 2 0. 9 1 7. 8 1 7. 3 1 5. 5 1 3. 8
8 0 2 7. 3 2 6. 4 2 5. 3 2 4. 2 2 3. 2 2 1. 9 2 0. 1 1 7. 7 1 6. 9 1 5. 1
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 2 0 3 4 0 3 60 3 80 4 00
1 90 1 81 1 7 3 16 4 15 5 14 7 13 8 1 29 1 21 1 1 2 10 3 9 5 8 6 7 7 6 9 6 0 5 2 4 3 3 4 2 6
PSI
0 30.0 27.9 25.5 23.0 20.0 16.0 10.0
20 29.9 29.0 27.9 25.5 23.0 20.0 16.0 10.0
30 29.9 29.0 27.9 26.9 24.0 21.8 18.5 13.9
40 29.8 29.0 27.9 26.9 25.9 2 3.0 20.0 15.9
50 29.7 29.0 2 7.9 26.9 2 5.5 2 4.0 21.8 18.5 1 3.9
60 29.7 29.0 27.9 2 6.9 25.5 24.0 23.0 20.0 16.0
70 30.0 29.6 29.0 28.8 26.9 25.5 24.0 23.0 22.0 18.8 14.0
80 30.0 29.6 29.0 28.8 26.9 25.5 24.0 23.0 22.0 20.0 16.0
6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 2 0 2 4 0 2 6 0 2 8 0 3 0 0 3 5 0 4 00 4 50 5 00 5 50 6 00 6 50
2 47 2 3 8 2 2 9 2 2 1 2 12 2 03 1 9 5 1 8 6 1 7 7 1 69 1 60 1 5 2 1 4 3 1 2 1 1 00 7 8 5 6 3 5
PSI
0 30.0 28.4 27.2 25.9 24.5 22.9 21.0 18.7 16.0 13.0
20 29.9 28.4 27.2 2 5.9 24.5 22.9 21.0 18.7 16.0 13.0
30 29.0 28.0 27.0 25.0 23.5 22.0 20.5 16.0 15.0
40 29.9 2 8.8 2 7.2 2 6.2 2 4.5 2 2.9 21.0 1 8.7 1 6.0 13.0
50 29.0 28.0 27.0 25.9 2 3.5 22.0 20.5 18.0 15.0
60 28.8 27.2 26.2 24.5 2 2.9 21.0 18.7 17.0 13.0
70 29.0 28.0 2 7.0 2 5.0 2 3.5 2 2.0 2 0.5 16.0 1 5.0
80 29.0 27.2 26.2 24.5 22.9 2 1.0 18.7 16.0
6 0 8 0 1 00 1 50 2 0 0 2 5 0 3 0 0 3 5 0 4 0 0 4 5 0 5 0 0 5 5 0 6 0 0 6 5 0 7 00 7 50 8 00 8 50 9 00 9 50
4 16 4 0 7 3 9 8 3 7 7 3 55 3 33 3 1 2 2 9 0 2 6 8 2 47 2 25 2 0 3 1 8 2 1 6 0 1 39 1 1 7 9 5 7 4 5 2 3 0
S I L V E R L I N E S E R I E S
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
320 1050
400
350
300
250
200
150
100
50
S4P-2060Hz
3450 rpm300
280
260
1000
950
850
900
30282624222018161412108640 2
7.006.005.004.003.002.00
800
750
700
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0.30
1.000
1.80
220
200
160
140
180
240
1.50
1.20
100
60
80
40
0
20
0.900.600
120
Q - (US gpm)
Q - (m /h)
Q - (lps)
32
S4P-20-05(HP)*
S4P-20-07(1HP)*
S4P-20-09(1HP)*
S4P-20-12(2HP)*
S4P-20-17(3HP)
S4P-20-28(5HP)
H-(m)
H-(PSI)
H-(ft)
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
2524
-
8/12/2019 Sub Pump Curve Catlg-60Hz
15/69
Per formance Table
Nominal Diameter : 4" Nominal Flow : 25 gpm Outlet Size : 1" NPT
Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 25 gpm Oultlet Size : 1" NPTDiameter
S I L V E R L I N E S E R I E S
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indi cate Most Efficient Perfor mance
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
S4P-25-05
S4P-25-07
S4P-25-13
S4P-25-22
PUMPMODEL
HP
1
77
106
136
197
332
2
1
3
5
PSI
S4V-25-05
S4V-25-07
S4P-25-09
S4V-25-09
0 36.0 32.0 2 7.0 2 1.0
20 35.0 31.0 25.0 18.0
3 0 3 4. 0 3 0. 0 2 4. 0 1 6. 0
4 0 2 8. 0 2 4. 0 1 5. 5
5 0 2 3. 0 1 4. 0
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 5 0 4 0 0 4 50 5 00 5 5 0
63 54 40 37 28 20 11
PSI
0 37.0 3 5.0 3 2.0 30.0 2 6.0 21.0 8.0
20 37.0 34.0 31.0 29.0 26.0 19.0
30 36.0 34.0 31.0 28.0 24.0 18.0
4 0 3 6. 0 3 3. 0 3 1. 0 2 8. 0 2 3. 0 1 5. 0
5 0 33 .0 3 0.0 2 7.0 2 2.0 1 4
6 0 30 .0 2 7.0 2 2.0 8 .0
7 0 26 .0 2 1.0 8 .0
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 5 0 4 0 0 4 50 5 00 5 50
91 83 74 65 57 48 39 30 22 13 4
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 5 0 4 0 0 4 50 5 00 5 50
1 28 11 9 11 0 10 2 93 8 4 7 6 67 5 8 50 41 32 24 15
PSI
0 38 35.4 32.7 30.9 29.0 25.2 2 0
20 37.4 34.7 31.4 30.4 28 23.9
30 36.7 34 31.8 30 27.1 22.6
40 36.7 34 31.8 30 27.1 2 2.6
50 36 33.4 31.4 29.5 26.2 21.3
60 38 35.4 32.7 30.9 29.0 25.2 20
7 0 35 .4 3 2.7 3 0.9 2 9.0 25. 2 2 0
80 31.4 30.4 28 23.9
PSI
0 38.9 37.9 36.7 34.6 32.7 27.7 22
20 38.7 37.6 36.2 34.1 31.5 30.2 27.5 21.8
30 38.4 37.3 35.7 33.7 31.3 3 0.2 27.7 25.8
40 38.4 37.3 3 5.7 33.7 3 1.3 3 0.2 27.7 25.6 2 2.4
50 38 37 35.3 33.3 31 29.8 27.4 25 22.2
60 38 37 35.3 33.3 31 29.8 27.4 25 22
70 38.9 37.9 36.7 34.6 32.7 30.2 29.6 27.2 24.5 22
8 0 3 8.9 3 7.9 3 6.7 34. 6 3 2.7 3 0. 1 29 .3 2 6. 9 24 .3 2 1.8
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 4 0 2 6 0 2 8 0 3 00 3 5 0 4 0 0 4 50 5 00 5 50
1 89 1 8 0 1 71 1 6 3 1 54 1 4 5 1 37 1 2 8 1 19 1 1 1 1 02 9 4 8 5 7 6 6 8 4 6 2 4
PSI
0 39.8 37.8 35.6 33.3 31 28 24
20 39.8 38 35.8 33.5 31.5 28.3 23.5
30 39.8 39 36.7 34.5 32.1 29.5 26
40 39.8 38.9 38 35.8 33.5 31.5 28.3 24.5
50 39.5 38.4 37.8 35.7 34.5 32.1 29.5 2 6
60 39.0 38.8 37.8 36.7 35.8 33.5 31.5 28.5 24.8
70 39.0 38.5 37.8 35.7 35.8 34.5 32.1 29.5 27.6
80 39.8 38.8 38.1 37.8 35.7 3 5.8 34.5 33.5 31.5 28.5 24.8
6 0 8 0 1 00 1 2 0 1 40 1 60 1 80 2 0 2 20 2 40 2 6 0 2 8 0 3 0 0 3 50 4 0 4 50 5 00 5 5 0 6 0 0 6 5 0 7 00
306 297 289 280 271 263 254 245 237 228 219 211 202 181 159 137 116 94 72 51
* Marked models are also available in Type-V construction.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
S4P-2560Hz
3450 rpm
1.61.20.80.40
0 1.0 2.0 3.0 4.0 5.0 6.0
2.4
9.0
2.0
7.0 8.0
Q - (lps)
Q - (m /h)
Q - (US gpm)403632
0
700
650
600
24201612 28
550
500
400
450
300
350
200
250
100
150
0 4
50
0
8
40
0
80
120
160
200
240
280
320
20
40
60
80
100
120
140
160
180
200
220
S4P-25-13 (3HP)
S4P-25-09 (2HP)*
S4P-25-07 (1HP)*
S4P-25-05 (1HP)*
H-(m)
H-(PSI)
H-(ft)
S4P-25-22(5HP)
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
2726
-
8/12/2019 Sub Pump Curve Catlg-60Hz
16/69
-
8/12/2019 Sub Pump Curve Catlg-60Hz
17/69
Nominal : 4" Nominal Flow : 50 gpm Outlet Size : " NPTDiameter 2
Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 50 gpm Oultlet Size : 2" NPTDiameter
Per formance Table
S I L V E R L I N E S E R I E S
S4P-5060Hz
3450 rpm
6050 70
4.8
1614
4.03.63.2
12
4.4
600180
500
240
160
200140
400
300
160
120
12080
100
S4P-50-20(7HP)
S4P-50-17(7HP)
S4P-50-13(5HP)
S4P-50-11(5HP)
40302010
2.8
108
2 2.41.6
6
1.2
4
0.80.4
2
200
8060
40
0
0
20
00
40100
0
0
S4P-50-08(3HP)
S4P-50-06(2HP)
S4P-50-05(2HP)
Q - (US gpm)
Q - (lps)
3Q - (m/h)
H-(m)
H-(PSI)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-50-05
PUMPMODEL HP
2
56
69
95
123
151
192
238
PSI
Shut Off - PSI
S 4P -5 0- 06 2
Shut Off - PSI
3S4P-50-08
Shut Off - PSI
5S4P-50-11
Shut Off - PSI
5S4P-50-13
Shut Off - PSI
7S4P-50-17
Shut Off - PSI
7S4P-50-20
0 74 70 66 61 57 51 45 37 2620 63 58 53 47 40 31 1130 50 45 35 2240 30 15
2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 10 1 20 1 30 1 4 0 1 50 1 60 1 7 0 18 0 19 0 20 0 2 10
46 4 1 3 7 33 2 9 2 4 20 16 11 7 3
PSI
0 75 72 68 65 61 58 53 46 37 30 18
20 69 66 62 58 53 49 43 33 2230 61 57 52 47 41 30 1740 50 44 36 24 550 34 22
2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 0 0 1 10 1 20 1 30 1 4 0 1 50 1 60 1 7 0 18 0 19 0 20 0 2 10
59 5 5 5 0 46 4 2 3 7 33 28 24 20 1 6 11 7 3
PSI
0 73 69 62 5 6 4 9 40 21
20 71 66 61 54 46 33
30 68 65 59 52 44 30 740 63 57 50 41 2650 56 49 39 2460 49 37 20
70 35 13
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 20 3 4 0 3 6 0 3 80 4 00
83 7 4 6 6 5 7 48 40 31 22 14 5
PSI
0 75 7 2 6 9 6 6 63 59 5 4 4 7 4 3 3 4 2 0 6
20 73 70 67 64 60 56 51 46 39 26 12 340 72 69 66 63 59 54 50 44 34 18 560 69 66 63 59 60 57 43 33 19 580 60 56 51 46 39 26 12 5
100 51 42 35 22 8
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 20 3 4 0 3 6 0 3 80 4 00
14 1 1 33 12 4 1 15 10 7 9 8 8 9 81 72 63 5 5 4 6 3 7 2 9 2 0 11 3
PSI
0 75 72 69 66 63 60 5 7 54 51 41 2520 73 70 67 64 61 58 55 52 49 45 41 2540 75 71 68 66 63 60 57 54 51 47 43 38 32 2560 71 68 66 63 60 57 54 51 47 43 38 32 25 15 380 64 61 58 55 52 49 45 41 35 29 21 9
100 58 55 51 48 44 40 35 26 19 7
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 50 4 0 0 4 5 0 5 00 5 50
1 82 1 74 1 6 5 15 7 14 8 1 39 1 31 1 22 1 1 3 1 05 9 6 8 7 7 9 7 0 6 1 4 0 1 8
PSI
0 74 72 70 68 66 63 61 54 47 36 20
20 75 73 71 69 67 6 5 62 60 57 54 47 36 2040 74 72 70 68 66 64 61 59 56 53 50 47 36 2060 74 72 70 68 66 63 61 59 56 53 50 47 43 39 25 580 71 69 67 65 62 60 57 54 51 40 45 41 36 30 24 5
100 66 63 61 59 56 53 50 47 44 39 34 27 20 12
2 0 4 0 6 0 8 0 1 00 1 2 0 1 4 0 1 6 0 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 0 0 4 50 5 0 0 5 50
2 28 2 1 9 2 1 1 2 02 1 93 1 8 5 1 7 6 1 6 7 1 59 1 50 1 4 1 1 33 1 24 1 15 1 0 7 8 5 6 3 4 2 2 0
PSI
0 75 72 68 64 60 56 52 4 6 37 25 4
20 74 70 62 60 58 54 49 41 34 1830 73 69 66 62 58 53 49 42 32 1840 68 65 61 56 51 45 40 25 7
60 60 56 51 46 37 24 7
80 49 43 33 22
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 20 2 4 0 2 6 0 2 8 0 3 00 3 20 3 4 0 3 6 0 3 80 4 00
113 105 9 6 8 7 7 9 70 61 53 44 35 27 18 9 2
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
3130
-
8/12/2019 Sub Pump Curve Catlg-60Hz
18/69
Nominal : 4" Nominal Flow : gpm Outlet Size : " NPTDiameter 70 2
Per formance Table Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 70 gpm Oultlet Size : 2" NPTDiameter
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-70-04
PUMPMODEL
HP
2
47
60
154
83
PSI
Shut Off - PSI
S4P-70-05 3
Shut Off - PSI
7S4P-70-13
Shut Off - PSI
5S4P-70-07
107Shut Off - PSI
5S4P-70-09
0 100 95 9 0 85 79 7 4 70 65 6 0 55 5010 93 88 87 81 76 81 67 61 56 49
20 89 84 78 73 68 64 60 55 49
30 65 60 56 52 48
5 10 15 20 25 30 35 40 45 50 5 5 6 0 65 70 75 80 85 90
46 43 41 39 37 35 33 30 28 26 2 4 2 2 20 17 15 13 11 9
PSI
0 107 103 95 81 77 70 62 50
10 103 100 94 90 787 82 79 68 5320 94 87 82 79 75 73 69 66 56 48
30 80 77 79 70 65 62 55 51
5 10 15 20 25 30 35 40 45 50 60 70 80 90 1 00 1 10 120 130
59 57 54 52 50 48 46 44 41 39 35 31 26 22 18 13
S I L V E R L I N E S E R I E S
PSI
0 100 95 8 7 83 76 71 6 6 6 1 56 5 0
20 100 90 85 80 75 67 63 57 54 45
30 95 87 73 76 71 66 61 56 50 4240 82 75 70 65 60 55 49 4350 67 63 57 54 45
1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00 1 10 1 20 1 3 0 1 40 1 50 1 6 0 1 70 1 80 1 9 0 2 00
79 75 71 66 62 58 53 49 45 40 36 32 27 23 19 14
PSI
0 105 96 87 79 70 62 54 4320 103 94 83 75 67 59 50 4030 100 93 84 73 66 57 48 3840 95 83 74 67 57 49 3650 50 80 71 63 55 45
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 2 0 3 4 0 3 60 3 80 4 00
98 90 81 73 64 55 47 38 29 21
PSI
0 104 97 9 2 8 5 78 72 6 7 62 5 6 4 9
20 102 9 6 90 83 76 70 65 60 54 48 3730 103 94 87 82 73 69 64 57 53 45 3540 101 94 87 83 75 68 63 57 53 45 35
50 96 91 84 77 71 66 61 55 48 43 34
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 2 0 3 4 0 3 60 3 80 4 00
1 46 1 37 1 29 1 20 11 1 10 3 9 4 8 5 7 7 6 8 5 9 5 1 4 2 3 3 2 5
1101009080706050403020
S4P-7060Hz
3450 rpm
10
1.0
2
0
0
00
40
0
0
80
120
160
200
240
280
320
360
20
40
60
80
100
120
10
30
50
70
90
110
20
40
80
60
120
100
160
140
2.0 3.0 4.0 5.0 6.0
4 6 8 10 12 14 16 18 20 22 24
Q - (US gpm)
Q - (lps)
Q - (m / h)
S4P-70-04(2HP)
S4P-70-05(3HP)
S4P-70-07(5HP)
S4P-70-09(5HP)
S4P-70-13(7HP)
H-(m)
H-(PSI)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
3332
-
8/12/2019 Sub Pump Curve Catlg-60Hz
19/69
Nominal : 4" Nominal Flow : gpm Outlet Size : " NPTDiameter 90 2
Per formance Table Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 90 gpm Oultlet Size : 2" NPTDiameter
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
S4P-90-03
PUMPMODEL HP
1
PSI
Shut Off - PSI
6S4P-90-13
Shut Off - PSI
5S4P-90-11
Shut Off - PSI
4S4P-90-09
Shut Off - PSI
3S4P-90-06
Shut Off - PSI
S4P-90-04 2
PSI
0 102 89 75
10 106 98 84 68
20 90 80 62
5 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00 1 10 1 20 1 30 1 40 1 50 1 60 1 70 1 80 1 90
34 28 23 19 1 5 1 0 6
S I L V E R L I N E S E R I E S
28
36
55
83
101
112
0 90 82 63
10 88 93 75 5020 51
5 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 00 1 10 1 20 1 30 1 40 1 50 1 60 1 70 1 80 1 90
26 24 19 15 1 1 6
PSI
0 102 91 82 73 58
10 99 89 80 7120 112 97 87 78 66
30 87 82 73 58
5 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 10 1 10 1 20 1 30 1 40 1 50 1 60 1 70 1 80 1 90
53 51 46 42 38 33 29 25 20 16 12
PSI
0 114 101 78 6 610 113 9 9 76 6420 112 97 73 62
30 107 89 72
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 70 2 8 0 2 9 0 3 0 0 3 10 3 2 0 3 3 0
74 65 57 48 39 31 22
PSI
0 115 99 87 79 68
20 112 98 86 77 6630 107 9 6 85 7540 107 93 83 7450 106 92 82 72
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 2 0 3 4 0 3 60 3 8 0 4 0 0
92 8 3 7 5 6 6 57 49 4 0 3 1 2 3
PSI
0 108 98 89 76 68
20 106 97 87 74 6 740 104 98 85 72 6560 116 103 94 83 72 6380 114 102 93 82 70 59
100 105 90 80 68
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 0 0 4 50 5 0 0 5 5 0
107 9 9 90 81 73 64 55 47 38 29
S4P-9060Hz
3450 rpm
00
0
40
60
80
100
120
10
30
50
70
90
110
20
20
130
140
150
10 20 30 40 50 60 70 80 90 100 110 120
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
20 4 6 8 10 12 14 16 18 20 22 24 26
Q - (m / h)
Q - (lps)
Q - (US gpm)
0
50
100
150
200
250
300
350
400
450
S4P-90-13(6HP)
S4P-90-11(5HP)
S4P-90-9(4HP)
S4P-90-6(3HP)
S4P-90-4(2HP)
S4P-90-3(1HP)
28
40
60
80
100
120
140
160
180
200
H-(m)
H-(PSI)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
3534
-
8/12/2019 Sub Pump Curve Catlg-60Hz
20/69
Nominal : 4" Nominal Flow : gpm Outlet Size : " NPTDiameter 90 2
Per formance Table Per fo rm anc e Curves
Nominal : 4" Nominal Flow : 90 gpm Oultlet Size : 2" NPTDiameter
HP
Shut Off - PSI
7S4P-90-16
Shut Off - PSI
10S4P-90-20
Shut Off - PSI
10S4P-90-22
145
182
201
S I L V E R L I N E S E R I E S
0 113 105 96 88 80 70
10 112 103 94 8 6 7 8 6 8
20 110 102 93 84 7 6
30 109 102 9 2 86 75
40 107 1 02 90 80 74
50 105 100 88 80 70
60 105 96 88 80 70
2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 00 2 20 2 40 2 60 2 80 3 0 0 3 5 0 4 00 4 5 0 5 0 0 5 5 0
1 32 1 23 1 14 1 06 9 7 88 8 0 7 1 6 3 54 45 37
PSI
0 113 105 97 89 81 72 62
10 113 105 97 89 81 72 6 2
20 114 106 98 9 0 82 7 2 6 3
30 114 107 9 9 91 83 73 64
40 114 107 99 91 83 73 64
50 113 1 05 97 89 81 72 62
60 113 105 97 89 81 72 62
2 0 4 0 6 0 8 0 1 00 1 25 1 5 0 1 7 5 2 0 0 2 25 2 50 2 75 3 00 3 25 3 5 0 3 7 5 4 00 4 2 5 4 5 0 4 7 5
1 71 1 63 1 54 1 4 5 13 7 12 6 11 5 1 04 9 4 8 3 7 2 6 1 5 0 3 9
PSI
0 110 104 97 90 82 74 66
10 110 104 97 90 82 74 66
20 111 105 98 91 83 75 6 7
30 110 104 97 9 0 82 7 4 6 6
40 110 104 9 7 90 82 74 66
50 11 1 05 9 8 91 83 75 67
60 110 1 06 99 92 84 76 68
2 0 4 0 6 0 8 0 1 00 1 25 1 5 0 1 7 5 2 0 0 2 25 2 50 2 75 3 00 3 25 3 5 0 3 7 5 4 00 4 2 5 4 5 0 4 7 5
1 88 1 8 0 1 71 1 6 2 1 5 1 43 1 3 2 1 21 1 1 0 1 00 8 9 7 8 6 7 5 6 4 5
S4P-9060Hz
3450 rpm
00
0
40
60
80
100
120
10
30
50
70
90
110
20
20
130
140
150
10 20 30 40 50 60 70 80 90 100 110 120
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
20 4 6 8 10 12 14 16 18 20 22 24 26
Q - (m / h)
Q - (lps)
Q - (US gpm)
0
50
100
150
200
250
300
350
400
450
S4P-90-22(10HP)
S4P-90-20(10HP)
S4P-90-16(7HP)
28
40
60
80
100
120
140
160
180
200
H-(m)
H-(PSI)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient PerformancePUMPMODEL
PSI
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
3736
-
8/12/2019 Sub Pump Curve Catlg-60Hz
21/69
Dimensions (in inches)& Weight (in lbs without packing)
4" Stainless theromoplastic Pump Ends -10 HP 5-90gpm
STAINLESS STEEL
S E R I E SDischarge in
gpm HP
No.ofStages
DischargeNPT
Pump End
Pump Model OD Ht. Wt.
11 1 S4P-5-11 3.8 17 10
5 15 1 S4P-5-15 3.8 22 11
1 19 1 S4P-5-19 3.8 25 14
10 1 S4P-7-10 3.8 18 10
13 1 S4P-7-13 3.8 21 12
1 17 1" S4P-7-17 3.8 26 13
1 21 1 S4P-7-21 3.8 29 16
2 26 1 S4P-7-26 3.8 35 19
2 28 1 S4P-7-28 3.8 36 20
6 1 S4P-10-06 3.8 15 8
8 1 S4P-10-08 3.8 17 9
10 1 10 1 S4P-10-10 3.8 19 10
1 14 1 S4P-10-14 3.8 23 13
2 17 1 S4P-10-17 3.8 27 16
3 24 1 S4P-10-24 3.8 33 18
5 1 S4P-15-05 3.8 15 8
7 1 S4P-15-07 3.8 17 10
15 1 9 1 S4P-15-09 3.8 19 10
1 12 1 S4P-15-12 3.8 22 12
2 15 1 S4P-15-15 3.8 26 14
3 22 1 S4P-15-22 3.8 34 19
5 1 S4P-20-05 3.8 15 8
1 7 1 S4P-20-07 3.8 17 1020 1 9 1 S4P-20-09 3.8 20 10
2 12 1 S4P-20-12 3.8 23 12
3 17 1 S4P-20-17 3.8 30 14
5 28 1 S4P-20-28 3.8 44 21
1 5 1" S4P-25-05 3.8 17 8
1 7 1" S4P-25-07 3.8 20 10
25 2 9 1" S4P-25-09 3.8 22 11
3 13 1" S4P-25-13 3.8 28 15
5 22 1" S4P-25-22 3.8 43 23
1 4 2" S4P-40-04 3.8 15 8
2 6 2" S4P-40-06 3.8 17 10
3 9 2" S4P-40-09 3.8 21 12
40 4 12 2" S4P-40-12 3.8 24 14
5 15 2" S4P-40-15 3.8 29 16
6 18 2" S4P-40-18 3.8 33 18
7 23 2" S4P-40-23 3.8 39 22
10 30 2" S4P-40-30 3.8 49 28
2 5 2" S4P-50-05 3.8 20 9
2 6 2" S4P-50-06 3.8 22 11
3 8 2" S4P-50-08 3.8 27 13
50 5 11 2" S4P-50-11 3.8 33 17
5 13 2" S4P-50-13 3.8 38 19
7 17 2" S4P-50-17 3.8 47 23
7 20 2" S4P-50-20 3.8 54 25
2 4 2" S4P-70-04 3.8 21 9
3 5 2" S4P-70-05 3.8 24 12
70 4 7 2" S4P-70-07 3.8 31 17
5 9 2" S4P-70-09 3.8 37 22
7 13 2" S4P-70-13 3.8 49 30
1 3 2" S4P-90-03 3.8 17 10
2 4 2" S4P-90-04 3.8 20 11
3 6 2" S4P-90-06 3.8 26 13
4 9 2" S4P-90-09 3.8 34 17
90 5 11 2" S4P-90-11 3.8 39 20
6 13 2" S4P-90-13 3.8 45 22
7 16 2" S4P-90-16 3.8 53 26
10 20 2" S4P-90-20 3.8 64 30
10 22 2" S4P-90-22 3.8 70 34
7
In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide.
SILVER LINE SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
38
-
8/12/2019 Sub Pump Curve Catlg-60Hz
22/69
Pumped Liquids
C.R.I. Submersible Pumps are the products of the expertise
gained from over five decadesofexperience, endurance and
workmanship. These products are engineered toperfectionwith
utmost care and stringent quality control at all stages to ensure a
trouble free service.
Description : C.R.I. 4, 6, 8 & 10 Stainless steel series
submersible pumps are made of corrosion resistance stainless
steel with built in check valve. All vital components of these pump
models are made of high quality 304 / 316 grade stainless steel
and theshaft is of S.S 304 / 329 / 431. The optimal design of
impellers and diffusers enables the best possible hydraulic
efficiency.
These pumps are of multistage centrifugal type, which can be
firmly coupled to a submersible electric motor, which operates
submerged beneath the surface of water. Built in check valve
prevents back flow, and reduces the risk of water hammer. All
mounting dimensions of pumps and motors are in accordance
with NEMA standards. C.R.I. Submersible pumps can be
offered with either C.R.I. 'W' Series, water filled rewindable
submersible motors / C.R.I. 'R' Series, encapsulated semi wet
type submersible motors C.R.I. "L" Series edible oil filled motors
or any other NEMA standard motors.
Features : Best operating efficiency Precise parts made of SS
304/316 Highly durable & Hygiene Good resistance to sand
Can be easily dismantled and repaired Can handle more
upthrust loads Available M.O.C. : Type S & N Additional
intermediate bearing in higher stage pumps Carbon upthrust
pad Rubber bust bearing in all stages SS 329 coupling for
longer life
Applications : Residential Irrigation Civil water supply
Fountains Industrial and rural water supply Fire fightingPressure boosting units Gardens Sprinkler systems
Mining Oil & Gas De-watering and food process industry
Golf course De-salination plants
l l
l l
l l
l l
l
l l
l l l
l l l
l l l
l l l
l l
Clean, Thin, Non-aggresive, Non explosive, Clear, Cold, Fresh Water without abrasives, Solid particles or fibrehaving the following characteristics
Maximum temperature of pumped liquid
Performance curve conditions
Motor Minimum cooling flow
along the motorVertical
installation
Horizontal installationminimum 30angle
4
6" & 8"
0.25 ft/s
0.5 ft/s
9 1. 4 3 3 C)F(
91.4F(33 C)
91.4F(33 C)
91.4F(33 C)
a) The performance curves show pump performance at rated Speed(3450r pm) and voltage
b) The measurements were made with airle ss water at a temperature of 68F (20C)
c) Pipe friction losses have not been included in the performance curves and charts.
d) Q/H: The curves are inclusive of check valve & suction inter-connector losses at the actual speed.
e) Efficiency curve Eff% shows pump stage efficiency
f) C urves tolerance is according to ISO - 9906 Annex-A
g) The performance are at rated voltage and are only indicative Actual discharge depe nds on availabilityof water in well, based on strength of water source, height of water column submergence of pump, etc.,.
h) The given performance are for the specified materials of construction of pump.
10 0.5 ft/s 91.4F(33 C) 91.4F(33 C)
4140
Temperature 91.4 C) (max)F (33a)
Permissible amount of sand 0.42 lb / 1000 gal (max)b)
Chlorine ion density 500 ppm (max)c)
Allowable solids 3000 ppm (max)d)
Specific gravity 1.004 (max)e)
Hardness (Drinking water) 300 ppm (max)f)
Viscosity 6 21.75 x 10m /sec (max)g)
Turbidity 50 ppm silica scale(max)h)
i) pH 6.5 to 8.5
G E N E R A L I N F O R M A T I O N
NOMINAL DIAMETER
POWER RANGE
SPEED
DISCHARGERANGE
TOTALHEAD
RANGE
US gpm
3m /h
ft
m
OUTLET SIZE IN INCHES
4(100mm)
0.3 - 10HP
3450 rpm
2 - 96
0.45 - 22
20 - 2220
6 - 677
1,1, 1 & 2
8(200mm)
7.5 - 125HP
3450 rpm
150 - 635
34 - 144
20 - 1270
6 - 387
5
6(150mm)
1.5 - 75HP
3450 rpm
21 - 400
5 - 91
10 - 2100
3 - 640
2,3 & 4
PUMP OPERATING LIMITATIONS
10(250mm)
15 - 250HP
3450 rpm
120 - 1080
27-245
25-1470
8-448
6
In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
-
8/12/2019 Sub Pump Curve Catlg-60Hz
23/69
Group Performance Curves Group Performance Curves
STAINLESS STEEL SERIESS T A I N L E S S S T E E L S E R I E S
300
50
0
100
0
100
200
150
250
300
200
400
350
450
400
500
600
500
550
700
0
400
200
600
800
1000
1200
1400
1600
1900
1800
2000
600
750
Q - (m/h)
100
6.3
24
0
0
1
4
2
8
3 4
12 16 20
5 6
0 20 40 60 80
Q - (US gpm)
130
8
28
10
36
14
50
18
70
Q - (lps)
22
90
26
110
30 34
150 250 450350 550 650
38 42
150
46 50
1 70 190
750 850 950 1050 1 150
54 58 62 66 70
210 230 250
800
650
S6S-75
S6S-9
0
S6S-1
10
S6S-
150
S6S-
240
S8S-
390
S8S-
475
S10S-
625
S10S-8
00
S6S-
300
H-(m)
H-(PSI)
H-(ft)
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.
Q - (m/h)
200
0
0
400
600
800
1000
1200
168 24 4032 48
Q - (US gpm)
7256 64 80 88 96
1400
1600
1800
2000
2200
2400
H-(ft)
H-(m)
S4S-
40
S4S-75S
4S-5
S4S-7
S4S-
10
S4S-
16
S4S-
25
0
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.5 6.05.0
0
40
120
80
160
200
280
240
320
400
360
440
480
520
560
600
640
720
680
0
100
200
300
400
500
600
700
800
900
1000
H-(PSI)
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
4342
-
8/12/2019 Sub Pump Curve Catlg-60Hz
24/69
Exploded view - 4 Radial Flow Pump
All mounting dimensions are in accordance with NEMA Standards
Part No. Part Name
Up Thrust washer
Sleeve
Suction Inter Connector
Wearing Ring
Locking Strap
Cable Guard
Chamber-Rubber Bush
Chamber-CT Pad
Bush-Rubber
Chamber - Bearing
Spacer
Chamber-Suction
Impeller
Valve Housing
Pump Shaft
Lock Nut
Nut
Screw
Spring Washer
13.03
13.05
17.00
17.01
17.03
17.04
18.00
18.05
18.06
18.09
18.12
18.17
19.00
21.00
22.00
32.06
32.07
32.12
32.14
Materials of Construction
CHECK VALVE HOUSING SS-304 SS-316 SS-304 SS-316
CHECK VALVE DISC SS-304 SS-316 SS-304 SS-316
CEHCK VALVE SEAT NBR NBR NBR NBR
DIFFUSER CHAMBER SS-304 SS-316 SS-304 SS-316
IMPELLER SS-304 SS-316 SS-304 SS-316
SPLIT CONE WITH NUT*** SS - 304 SS-316 SS-304 SS-316
IMPELLER WEAR RING /NBR NBR NBR NBR
SEAL (NECK) RING
UP THRUST WASHER / SS-304/TEFLON / SS-316 / SS-420/ SS-329/
STOP RING SS - 420 / BRONZE TEFLON CARBON CARBON
INTERMEDIATE BEARING NBR NBR NBR NBR
SUCTION INTERSS-304 SS-316 SS-304 SS-316
CONNECTOR
INLET SCREEN SS-304 SS-316 SS-304 SS-316
PUMP SHAFT SS-304 / 431** SS-329** SS-431 SS-329
COUPLING SPLINES SS-329 SS-329 SS-329 SS-329
LOCKING STRAPS SS-304 SS-316 SS-304 SS-316
CABLE GUARD SS-304 SS-316 SS-304 SS-316
PART NAMENOMINAL DIA. 4"
TYPE - NTYPE - S TYPE - S
NOMINAL DIA. 6", 8" & 10
TYPE - N
** Provided only for 4" - 75 gpm*** Applicable for 4" - 75 gpm and 6" - 75 gpm to 300 gpm
Note : 4" - 5 gpm to 40 gpm pumps are provided with hexagonal shaft and other pumps are with cylindrical shaft.
21.00
18.05
32.06
13.05
13.03
17.01
18.00
18.06
19.00
17.01
18.09
18.06
13.05
17.01
18.00
18.06
19.00
17.01
18.00
18.06
19.00
17.03
32.14
32.07
18.17
18.12
17.01
32.12
17.04
17.00
22.00
32.12
G E N E R A L I N F O R M A T I O N
In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
4544
-
8/12/2019 Sub Pump Curve Catlg-60Hz
25/69
All mounting dimensions are in accordance with NEMA StandardsAll mounting dimensions are in accordance with NEMA Standards
Exploded view - 4 Mixed Flow Pump Exploded view - 6 Radial Flow Pump
32.12
21.00
19.03
19.00
19.02
17.01
18.00
18.06
19.03
19.00
19.02
32.1217.01
18.00
18.06
19.03
19.00
19.02
17.01
18.02
18.05
13.03
19.00
19.02
17.01
18.19
18.12
22.00
17.00
17.03
32.14
32.07
17.04
32.00
Part No. Part Name
Up Thrust washer
Sleeve
Suction Inter Connector
Wearing Ring
Locking Strap
Cable Guard
Chamber-Rubber Bush
Chamber-CT Bearing
Bush-CT Pad
Bush-Rubber
Spacer
Chamber-Top
Impeller
Split Cone
Split Cone Nut
Valve Housing
Valve Seat
Valve Disc
Pump Shaft
Key
Nut
Screw
Spring Washer
13.03
13.05
17.00
17.01
17.03
17.04
18.00
18.02
18.05
18.06
18.12
18.19
19.00
19.02
19.03
21.00
21.01
21.06
22.00
32.05
32.07
32.12
32.14
21.00
21.06
21.01
18.19
18.06
19.03
19.00
19.02
17.01
18.00
18.06
19.03
19.00
19.02
17.01
18.00
18.06
19.03
19.00
19.02
13.05
17.01
18.02
18.05
13.03
32.12
17.04
18.12
22.00
17.03
32.14
32.07
17.00
32.05
Part No. Part Name
Up Thrust washer
Suction Inter Connector
Wearing Ring
Locking Strap
Cable Guard
Chamber-Rubber Bush
Chamber-CT Bearing
Bush-CT Pad
Bush-Rubber
Spacer
Chamber-Suction
Impeller
Split Cone
Valve Housing
Pump Shaft
Bolt
Screw
Spring Washer
13.03
17.00
17.01
17.03
17.04
18.00
18.02
18.05
18.06
18.12
18.19
19.00
19.02
21.00
22.00
32.00
32.12
32.14
G E N E R A L I N F O R M A T I O N
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
4746
-
8/12/2019 Sub Pump Curve Catlg-60Hz
26/69
All mounting dimensions are in accordance with NEMA StandardsAll mounting dimensions are in accordance with NEMA Standards
Exploded view - 6 - Mixed Flow Pumps Exploded view - 8 & 10 - Mixed Flow Pumps
21.00
17.03
21.02
21.06
21.01
32.09
21.05
18.00
18.06
19.03
19.00
19.02
12.05
18.06
18.02
17.01
19.02
19.00
19.03
18.06
18.00
14.03
32.07
17.00
22.01
32.04
18.12
17.01
22.00
19.02
19.00
13.03
32.05
17.04
32.12
32.12
17.01
19.02
19.00
19.03
18.06
18.00
17.01
Part No. Part Name
Counter Thrust Ring
Up Thrust
WasherStrainer
Suction Inter Connector
Wearing Ring
Locking Strap
Cable Guard
Chamber-Rubber Bush
Bush-Rubber
Spacer
Impeller
Split Cone
Split Cone nut
Valve Housing
Valve Seat
Valve Spring
Valve Bracket
Valve Disc
Pump Shaft
Coupling
Grub Screw
KeyNut
O-Ring
Screw
12.05
13.03
14.03
17.00
17.01
17.03
17.04
18.00
18.06
18.12
19.00
19.02
19.03
21.00
21.01
21.02
21.05
21.06
22.00
22.01
32.04
32.0532.07
32.09
32.12
Part No. Part Name
Up Thrust washer
Suction Inter Connector
Wearing Ring
Locking Strap
Cable Guard
Chamber-Rubber Bush
Chamber-CT bearing
Bush-CT Pad
Bush-Rubber
Spacer
Chamber-Top
Impeller
Neck Ring
Split Cone
Split Cone Nut
Valve Housing
Valve Seat
Valve Disc
Pump ShaftNut
Screw
Spring Washer
13.03
17.00
17.01
17.03
17.04
18.00
18.02
18.05
18.06
18.12
18.19
19.00
19.01
19.02
19.03
21.00
21.01
21.06
22.0032.07
32.12
32.14
21.00
21.06
21.01
18.19
18.06
19.03
19.00
19.02
19.01
17.01
17.03
32.14
32.07
18.00
18.06
19.03
19.00
19.02
19.01
17.01
18.02
18.05
13.03
19.00
19.02
17.04
32.12
18.12
22.00
17.01
17.00
19.01
32.12
G E N E R A L I N F O R M A T I O N
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
4948
-
8/12/2019 Sub Pump Curve Catlg-60Hz
27/69
Depth To Pumping Water Level or Lift, in Feet.Shaded Areas Indicate Most Efficient Performance
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
Shut Off - PSI
S4S-5-09
S4S-5-13
S4S-5-18
S4S-5-22
S4S-5-26
S4S-5-31
S4S-5-39
S4S-5-48
PUMPMODEL
HP
1/3
112
160
212
270
316
354
450
597
3/4
1
1/2
1
1
2
3
PSI
PSI
0 7.5 7 6 5.5 5 4 3.5 2.5
20 7.5 7 6.5 5.5 5 4 3.5 2.5 1
30 7 6.5 6 5.5 4.5 4 3 2
40 7.5 7 6.5 5.5 5 4.5 3.5 2.5 160 7.5 7 7 6 .5 5.5 5 4.5 3.5 2.5 180 7.5 7 7 6.5 6.5 6 6 4.5 3.5 2.5 1
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 5 0 3 00 3 50 4 00 4 5 0 5 0 0 5 5 0 6 00 6 5 0 7 0 0
2 65 2 5 7 2 4 8 2 3 9 2 3 0 2 09 1 8 7 1 6 9 1 4 3 1 22 1 00 7 8 5 7 3 9
Per formance Table
Nominal Diameter : 4" Nominal Flow : 5 gpm Outlet Size : 1" NPT Nominal Diameter : 4" Nominal Flow : 5 gpm Outlet Size : 1" NPT
Per fo rm anc e Curves
In view of continuous developments, the given information / descriptions / specifications / illustrations are subject to change without notice.
0 8 7.2 6.5 5.9 5 4
20 8 7 6.3 5.7 4.6 3.6 2.530 7.6 7 6.3 5.5 4.5 3.5 2.3
40 7.7 7 6.2 5.5 4.5 3.5 2.3
60 6 5 4 2.980 3.8 2.5
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 5 0 3 00 3 50 4 00 4 5 0 5 0 0 5 5 0 6 00 6 5 0 7 0 0
104 9 5 86 78 70 60 52 43 32 26
0 8 7.5 7 6.5 5 3.5 1
20 7.5 7 7 6.5 6 5.5 3.5 130 7.5 7 7 6.5 5 .5 5 4.5 2 .540 7.5 7 6.5 6 5.5 5 4.5 3.5 1.560 7.5 7 6.5 6 5.5 5 4 3.5 2.5 1.5
80 6.5 6 5.5 4.5 4 3.5 2.5 1
PSI 2 0 4 0 6 0 8 0 1 00 1 20 1 4 0 1 6 0 1 8 0 2 0 0 2 50 3 0 0 3 5 0 4 0 0 4 50 5 00 5 5 0 6 0 0 6 50 7 00
1 52 1 43 1 35 1 36 1 25 1 17 1 00 9 1 8 3 7 4 5 2 3 0 9
PSI
0 8 7 6 5 3.5 2
20 7.5 7.5 7 6 5 3.5 2
30 7.5 7 7 6 .5 5.5 4.5 3 1
40 7.5 7 7 6 .5 6 5 3.5 2
60 7.5 7 6.5 6 .5 6 5.5 5 4 2.580 8 7.5 7 6.5 6 6 5.5 5 4.5 4 2.5 1
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 5 0 3 00 3 50 4 00 4 5 0 5 0 0 5 5 0 6 00 6 5 0 7 0 0
2 04 1 9 6 1 8 7 1 78 1 7 0 1 61 1 5 2 1 43 1 3 5 1 28 1 0 4 8 3 6 1 3 9 1 7
PSI
0 8 7 6.5 6 5.5 4 4.5 3.5 2.5
20 7.5 6.5 6 5.5 5 4.5 3.5 2.5 1.5
30 7.5 7 6.5 6 5.5 4.5 4 3 2.5
40 7.5 6.5 6 5.5 5 4.5 3.5 3 1.560 7.5 7 6 .5 5.5 5.5 4.5 4 3.5 2.580 7.5 7.5 7 7 6 5 .5 5 4.5 4 3 2 1
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 5 0 3 00 3 50 4 00 4 5 0 5 0 0 5 5 0 6 00 6 5 0 7 0 0
2 96 2 8 7 2 7 8 2 70 2 4 8 2 26 2 04 1 83 1 6 1 1 3 9 1 1 7 9 6 7 4 5 2
PSI
0 7.5 7 7 6 .5 6 5.5 5 4.5 4 3 2 .5 1
20 7.5 7 7 6.5 6 5.5 5 4.5 4 3 2.5 1 .530 7.5 7 6.5 6 5.5 5 4.5 4 3.5 3 1.7
40 7.5 7 7 6.5 6 5.5 5 4.5 4 3 2.560 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 2.5 180 8 7.5 7 6.5 6 5.5 5 4.5 4 3.5 2.5 1
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 1300
3 43 3 2 2 3 00 2 78 2 5 7 2 35 2 1 3 1 91 1 70 1 43 1 2 6 1 4 8 3 6 1 3 9 1 7
PSI
0 7.5 7.5 7 7 6.5 6.5 6 5.5 5.5 5 4.5 4 3 1.8
20 7.5 7 .5 7 7 6.5 6.5 6 5.5 5 .5 5 4.5 4 3 2.530 7.5 7.5 7 6.5 6 .5 6 6 5.5 5 5 4.5 4 3 240 7.5 7.5 7 7 6.5 6.5 6 5.5 5.5 5 4.5 4.5 4 3 1.8
60 7.5 7.5 7 7 6.5 6.5 6 5.5 5.5 5 4.5 4.5 4 3.5 2.5
80 7.5 7.5 7 7 6.5 6.5 6 5.5 5.5 5 4.5 4.5 4 3.5 3 2
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 1300
4 65 4 43 4 2 2 4 0 0 3 7 8 3 5 7 3 3 5 3 13 2 9 1 2 7 0 2 4 8 2 2 8 2 0 4 1 8 3 1 81 1 17 7 4 3 0
S T A I N L E S S S T E E L S E R I E S
PSI
0 7.5 7 6 5.5 4.5 3.5 2.520 7.5 7 6 5 .5 4.5 3.5 2.5
30 7.5 7.5 6.5 6 5 4 3 240 7.5 7.5 7 6 5 .5 4.5 3.5 2.5 1
60 7.5 7 7 6.5 6 5.5 4.5 3 .5 2.5 180 7.5 7.5 7 6.5 6.5 6 6 5.5 4.5 3.5 2.5 1
2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 60 1 80 2 00 2 5 0 3 00 3 50 4 00 4 5 0 5 0 0 5 5 0 6 00 6 5 0 7 0 0
2 46 2 3 7 2 28 2 20 2 1 1 2 02 1 9 3 1 85 1 6 3 1 41 1 2 0 9 8 7 0 5 4 3 3
Refer general information for performance curve conditions and for other details.
Curve tolerances according to ISO 9906, Annex-A.
Q -(m/h)
30 1 2 4 5 76 8
Q -(US gpm)
0.00
0.12
0.04
0.08
P2(kW)
0.00
0.08
0.16
P2HP
0
10
20
30
40EFF%
P2
3
0 0.20 0.600.40
0
200
100
1 2
1.00.80 1.20 1.601.40 1.80
4 5 76 8
300
500
400S4S-5-13(HP)
600
800
700
900
1000
1100
S4S-5-39(2HP)
1200
1300
S4S-5-48(3HP)
S4S-560Hz
3450 rpm
150
50
0
100
50
100
150
200
250
0
400
350
300
250
200
300
350
400
450
500
550
Q -(US gpm)
0
H-(m)
H-(PSI)
H-(ft)
EFFICIENCY(%)
S4S-5-09( HP)31
S4S-5-18(HP)
S4S-5-22(1HP)
S4S-5-26(1HP)
S4S-5-31(1HP)
Pumping trust. Worldwide.
STAINLESS STEEL SERIES
C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N
5150
-
8/12/2019 Sub Pump Curve Catlg-60Hz
28/69
Per formance Table
Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT Nominal Diameter : 4" Nominal Flow : 7 gpm Outlet Size : 1" NPT
Per fo rm anc e CurvesDepth To Pumping Water Level or Lift, in Feet.Shaded Areas Indic ate Most Efficient Perform ance
Shut Off - PSI
S4S-7-08
PUMPMODEL
HP
1/3
101
PSI
134Shut Off - PSI
S4S-7-11 1/2
Shut Off - PSI
S4S-7-15 3/4
171
Shut Off - PSI
S4S-7-19 1
225
Shut Off - PSI
S4S-7-26 1
298
Shut Off - PSI
S4S-7-32 2
385
P2(HP)
Q -(US gpm)0 21 43 5 6 87 109 11 12
0.00
0.12
0.04
0.08
P2(kW) 0.16
0.00
0.08
0.16
0.24
0
10
20
30
40
EFF%
P2
Q -(m/h)
S T A I N L E S S S T E E L S E R I E S
0 10.7 9.7 8 .5 7.3 5 .7 4
20 10.3 9.3 8.3 7.5 5.4 3.4
30 10.2 9 8 6.5 5
40 10 9 8 6.5 4.5
50 8.9 7.2 6.2 4.5
60 7.6 5.6 4.1
70 5.5 3.9
2 0 4 0 6 0 8 0 1 00 1 20 1 40 1 60 1 8 0 2 0 0 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 00 4 5 0 5 0 0
93 84 75 67 58 49 41 32 23 15
0 11 10 9.5 8.5 7 .5 6.5 5.5 4 3 1.7
20 11 10 9 8 7 6 5 3.5 2 .5 1 .7
30 10.5 9 .5 9 8 7 6 5 3.5 2.3
40 10.5 9.5 8.5 8 7 5.5 4.5 3.5 2
50 9.5 8.5 7.5 6.5 5.5 4.5 3 2
60 8.5 7.5 6.5 5.5 4 3 1.7
70 7.5 6.5 5 4 3 1.5
PSI 2 0 4 0 6 0 8 0 1 00 1 20 1 40 1 60 1 8 0 2 0 0 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 00 4 5 0 5 0 0
1 24 115 1 07 9 8 89 80 72 6 3 5 4 4 6 3 7 28 2 0 1 1
PSI
0 11 1 0 9.5 9 8 .5 8 7 6.5 4.5 3.5
20 10.5 10 9.5 9 8.5 7.5 7 6 5.5 4.5 3.5
30 10.5 10 9.5 9 8 7.5 7 6 5.5 4.5 3.5 2.540 10.5 10 9.5 8.5 8 7.5 6.5 6 5 4.5 3.5 2.3
50 11 10.5 9.5 9 8.5 8 7.5 6.5 6 5 4.5 3.5 2.3
60 10 9.5 9 8.5 8 7 6.5 5.5 5 4 3 2.5
70 9.5 9 8.5 7.5 7 6.5 5.5 5 4 3 2.5
2 0 4 0 6 0 8 0 1 00 1 20 1 40 1 60 1 8 0 2 0 0 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 00 4 5 0 5 0 0
1 63 1 54 1 46 1 37 1 28 1 20 1 11 1 02 9 3 8 5 7 6 6 7 5 9 5 0 4 1 2 0
PSI
0 11 10.5 10 10 9.5 9 8 .5 7 5 .5 4
20 11 10.5 10 9 .5 9 8.5 8.5 8 7 6 4 1.5
30 11 10.5 10 9 .5 9 8.5 8 7.5 7 6.5 5 3
40 1 10.5 10 9.5 9 8.5 8 7.5 7 6.5 6 4 1.6
50 11 10.5 1 0 9.5 9 8.5 8 7.5 7 6.5 6 5 3
60 10.5 10 10 9.5 9 8.5 8 7.5 7 6.5 5.5 5 4.5 1.7
70 10.5 10 9.5 9.5 9 8.5 8 7.5 7 6 5.5 5 4 3.5
2 0 4 0 6 0 8 0 1 00 1 20 1 40 1 60 1 8 0 2 0 0 2 2 0 2 40 2 60 2 80 3 0 0 3 5 0 4 00 4 5 0 5 0 0
2 07 1 9 8 1 8 9 1 80 1 7 2 1 6 3 1 54 1 4 6 1 3 7 1 28 1 2 0 1