submittal review - comma-q€¦ · residential and light commercial floors and countertop...

5
SUBMITTAL REVIEW Submittal: No. 033.01 Spec Section: 09 2116 GWB Assemblies - Tile Backer Board and Reveal Moldings Reviewed By: Laura Landon, Comma-Q Architecture Date: October 30, 2012 Project: BPS – Belgrade Elementary School Location: Belgrade, MT Job Number: 11-03 Copy to: File, Owner This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the submittals during this review do not relieve the CONTRACTOR from compliance with the requirements of the plans and specifications. An opinion of equivalence of a specific item shall not be interpreted as an opinion of equivalence of an assembly of which the item is a component. Submittal review comments have been made within this format and not on the submittal sheets according to the following: NEN No Exceptions Noted GCAN Generally Conforms as Noted RAN Rejected for Reason as Noted IAS Incomplete as Submitted 1. 09 2116 GWB Assemblies - Tile Backer Board and Reveal Moldings Data Sheets GCAN Notes: 1. Provide 5/8” thick tile backer board per specification 2. Reveal molding finish to be Clear Anodized Aluminum. END OF REVIEW

Upload: others

Post on 06-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUBMITTAL REVIEW - Comma-Q€¦ · residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming

SUBMITTAL REVIEW Submittal: No. 033.01 Spec Section: 09 2116 GWB Assemblies - Tile Backer Board and Reveal Moldings Reviewed By: Laura Landon, Comma-Q Architecture Date: October 30, 2012 Project: BPS – Belgrade Elementary School Location: Belgrade, MT Job Number: 11-03 Copy to: File, Owner

This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the submittals during this review do not relieve the CONTRACTOR from compliance with the requirements of the plans and specifications. An opinion of equivalence of a specific item shall not be interpreted as an opinion of equivalence of an assembly of which the item is a component. Submittal review comments have been made within this format and not on the submittal sheets according to the following:

NEN No Exceptions Noted GCAN Generally Conforms as Noted RAN Rejected for Reason as Noted IAS Incomplete as Submitted

1. 09 2116 GWB Assemblies - Tile Backer Board and Reveal Moldings Data Sheets GCAN

Notes: 1. Provide 5/8” thick tile backer board per specification 2. Reveal molding finish to be Clear Anodized Aluminum.

END OF REVIEW

Page 2: SUBMITTAL REVIEW - Comma-Q€¦ · residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming

MARTEL CONSTRUCTION, INC. LETTER OF TRANSMITTAL1203 South Church Avenue Bozeman, MT 59715-5801

Telephone: (406) 586-8585 Facsimile: (406) 586-8646 DATE 10/26/12 JOB NO. 12-001TRANSMITTAL/SUBMITTAL NO. 33.01

TO: Comma Q Architects RE: Gypsum Board Assembles - Product Data109 North Rouse Ave #1 Re-Submittal Bozeman, MT 59715

ATTENTION: Laura Landon BELGRADE ELEMENTARY SCHOOL

We are hand deliveringWe are sending via Email

X ATTACHED UNDER SEPARATE COVER TheThe following items:

Shop drawings Prints Plans Samples Specifications

Copy of letter Change order X Product Data

COPIES DATE DWG NO. DESCRIPTION

11

09 2116 Gypsum Board Assembles - 2.03 DENSHIELD TILE BACKER 09 2116 Gypsum Board Assembles - 2.04 Reveal Molding for GWB

THESE ARE TRANSMITTED as checked below:X For approval Approved as Submitted Resubmit Copies for Approval

For your use Approved as Noted Submit Copies for Distribution As requested Returned for Corrections Return Corrected Prints For review and comment

FOR BIDS DUE PRINTS RETURNED AFTER LOAN TO US

REMARKS:

COPY TO File SIGNED: Mike Wilkinson - Project Engineer

If enclosures are not as noted, kindly notify us at once.

Page 3: SUBMITTAL REVIEW - Comma-Q€¦ · residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming

Stamps/Signatures

continued

Job Name

Contractor

Date

Submittal Approvals

Technical Service Hotline 1.800.225.6119 or

www.densshield.com

ManufacturerGeorgia-Pacific Gypsum LLC Georgia-Pacific Canada LP 133 Peachtree Street 7070 Mississauga Road, Unit 120 Atlanta, GA 30303 Mississauga, ON L5M 7V9 Technical Service Hotline: 1-800-225-6119

DescriptionDensShield® Tile Backer is a substrate that, when properly installed, provides significant water and moisture resistance — making it excellent for protecting both tile installations and stud cavities. DensShield Tile Backer is composed of a water-resistant treated core that is covered front and back with fiberglass mats. The mats are permanently integrated with the core during manufacturing, preventing delamination problems that can occur with paper-faced greenboard. On the tile side, DensShield Tile Backer’s exclusive heat-cured acrylic coating stops surface water and retards moisture transmission, protecting the wall cavity.

Unlike cementitious backer boards, DensShield Tile Backer has a built-in water barrier. DensShield Tile Backer is 17 lbs (7.7 kg) to 32 lbs (15 kg). lighter per panel, depending on panel size, than cement board, which makes installation easier. DensShield Tile Backer provides excellent dimensional stability and strength so it can be installed parallel or at right angles to framing in wall and ceiling applications.

DensShield Tile Backer, with its fiberglass mat design, has been indepen-dently tested, as manufactured, in accordance with ASTM D 3273 and has scored the highest achievable rating (10 out of 10) for mold resistance. DensShield Tile Backer has been shown to be excellent for tile and non-tile installations in wet and non-wet applications, in areas of high humidity, and in appropriate fire-rated wall assemblies. It is ideal for interior walls, ceilings, residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming pool areas and locker rooms.

Primary UsesDensShield Tile Backer is the first and only tile backer listed as a GREENGUARD microbial-resistant product by a leading third-party organization, GREENGUARD Environmental Institute. This listing means DensShield Tile Backer, which features fiberglass mats instead of the paper facings used on the surface of traditional tile backers, resists mold growth. The microbial-resistant test is based on ASTM Standard D 6329, a testing standard set by ASTM International, which develops testing guidelines and procedures for building material, products, systems and services.

DensShield Tile Backer provides an excellent backer for sidewalls and ceilings in bathtub and shower installations, where it provides an even, solid substrate for tile. DensShield Tile Backer may also be finished with paint or wallpaper for non-tile areas that require superior fire and moisture resistance where its moisture barrier and water-repelling qualities are desirable. DensShield Tile Backer also adds stabilizing and fire resistant qualities to countertop installations.

1/4( (6.4 mm) and 1/2( (12.7 mm) x 4* (1220 mm) wide DensShield Tile Backer can be used as a substrate in floor tile applications for residential and light commercial use as defined in the Handbook for Ceramic Tile Installation published by the Tile Council of North America.

LimitationsTiles should be applied on the grey coated side of DensShield Tile Backer.

DensShield Tile Backer should not be used in commercial saunas, steam rooms, around fireplaces or areas where prolonged exposure to heat exceeds 125° F (52° C).

DensShield Tile Backer panels should not be used as a shower pan base.

DensShield Tile Backer should not be used for exterior installations.

DensShield Tile Backer panels should not be used as a base for nailing and mechanical fastening.

DensShield Tile Backer should not be used in conjunction with passive solar heat systems.

For floors, use floor grade tile, 2( x 2( (51 mm x 51 mm) or larger.

Use framing or furring when applying over concrete or masonry block.

Adhesives alone should not be used to install DensShield Tile Backer. Nails, screws or staples may be used alone or in combination with adhesives.

Since DensShield Tile Backer has a built-in moisture barrier; never install vapor retarders directly behind DensShield Tile Backer panels. In retrofit applications, some paints or other wall coverings may constitute a vapor barrier; remove or effectively penetrate these coverings prior to installing DensShield Tile Backer panels.

DensShield Tile Backer should not be used in shower floors.

Technical DataDensShield Tile Backer panels are mold-resistant, and have scored a 10, the highest level of performance for mold resistance under the ASTM D 3273 test method.

When tested in conformance with ASTM E 96, DensShield Tile Backer panels achieved a perm rating of less than 1.5 (42.9 ng/Pa •s •m2) alone, 1.0 (28.6) with dry set mortars.

In a test by an independent testing laboratory, DensShield Tile Backer was subjected to a shower of water at 110°F (43.3°C), 12 minutes per hour, 24 hours a day, 7 days a week for six months. The installation had no grout between the tiles. No deterioration occurred to either the DensShield Tile Backer board, the framing members or the wall cavity.

Page 4: SUBMITTAL REVIEW - Comma-Q€¦ · residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming

5/8 ( (15.9 mm) DensShield® Fireguard® Tile Backer is UL and ULC classified as Type DS and included in numerous assembly designs invested by UL and ULC for hourly fire resistance ratings, including1-hour and 2-hour wall assemblies.

5/8 ( (15.9 mm) DensShield Fireguard Tile Backer is classified as “Type X” in accordance with ASTM C 1178 and may replace Type X gypsum board specified in generic rated wall assemblies listed in the Gypsum Association Fire Reference Design Manual, Publication GA-600.

DensShield Tile Backer has passed the Robinson Floor Test/ASTM C 627 in both 1/4 ( (6.4 mm) and 1/2( x 4* (12.7 mm x 1220 mm) wide thicknesses with a rating of light commercial.

Sizes and EdgesThickness Width x Length1/4( (6.4 mm) 4* x 4* (1220 mm x 1220 mm)1/2( (12.7 mm) 32( x 5* (813 mm x 1524 mm) 4* x 5* (1220 mm x 1524 mm) 4* x 8* (1220 mm x 2438 mm)5/8( (15.9 mm) 4* x 8’ (1220 mm x 2438 mm)

Edges: Square Conforms to ASTM C 1178 Fiberglass Mat Water-Resistant Gypsum Backing Panel

Technical Service Hotline 1.800.225.6119 or

www.densshield.com

©2011 Georgia-Pacific Gypsum LLC. All rights reserved. Printed in the U.S.A. on 10% post-consumer recycled stock. 1/11 GP-TM Lit. Item #532266.

U.S.A.– Georgia-Pacific Gypsum LLCCanada – Georgia-Pacific Canada LP

SALES InforMATIon AnD orDEr PLAcEMEnTU.S.A. Midwest: 1-800-876-4746 West: 1-800-824-7503 South: 1-800-327-2344 Northeast: 1-800-947-4497

CANADA Canada Toll Free: 1-800-387-6823 Quebec Toll Free: 1-800-361-0486

TEcHnIcAL InforMATIon U.S.A. and Canada: 1-800-225-6119 www.gpgypsum.com

TrADEMArKS DENSSHIELD, FIREGUARD and the GEORGIA-PACIFIC logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. GREENGUARD is used under license through the GREENGUARD Environmental Institute. WArrAnTIES, rEMEDIES AnD TErMS of SALE For current warranty information for this product, please go to www.gpgypsum.com and select the product for warranty information. All sales of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com.UPDATES AnD cUrrEnT InforMATIon The information in this document may change without notice. Visit our website at www.gpgypsum.com for updates and current information.cAUTIon for product fire, safety and use information, go to www.gp.com/safetyinfo or call 1-800-225-6119.HAnDLInG AnD USE–cAUTIon This product contains fiberglass facings which may cause skin irritation. Dust and fibers produced during the handling and installation of the

product may cause skin, eye and respiratory tract irritation. Avoid breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use a dust mask or NIOSH/MSHA approved respirator as appropriate in dusty or poorly ventilated areas.fIrE SAfETY cAUTIon Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/sys-tems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions neces-sary for your safety and the safety of others without regard for any fire rating of any product or assembly/system.

laura
Rectangle
laura
New Stamp
laura
Text Box
X
laura
Text Box
Laura Landon 10/30/12
Page 5: SUBMITTAL REVIEW - Comma-Q€¦ · residential and light commercial floors and countertop applications in high moisture areas such as baths, showers, kitchens, laundries, swimming
laura
Text Box
FINISH TO BE CLEAR ANODIZED ALUMINUM.
laura
Rectangle