substation protection devices
TRANSCRIPT
![Page 1: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/1.jpg)
Presentation on
Substation Protection Devices
Presented by: Rahul KumarRoll no. 125069Regd. No. 1201211280Department of Electrical EngineeringOrissa engineering college
Guided by:ER.DEBASHISH MISHRAASST. PROFESSORDEPARTMENT OF ELECTRICAL Engineering
![Page 2: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/2.jpg)
Contents Introduction Protection devices Protection requirement Current transformer(CT) Potential transformer(PT) Relay Circuit breaker Lightning arrester Isolators Conclusion
![Page 3: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/3.jpg)
Introduction Substation Protection system
Power System-Protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults through the isolation of faulty parts.
A typical substation
![Page 4: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/4.jpg)
Why Do We Need Protection
The objective of a protection scheme is to keep the power system stable by isolating only the components that are under fault, whilst leaving as much of the network as possible still in operation.
Under abnormal working condition protection is necessary for safety of electrical equipments and safety of human being.
![Page 5: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/5.jpg)
Switchgear And Protection Devices
What are the Protection devices? The apparatus or equipments and their
associated auxiliaries employed for controlling, regulating and switching on or off the electrical circuits in the electrical power system is known as “Protection devices” or “switchgear”.
Protection devices protect the transmission lines, generators, transformers and other electrical equipments from various “faults”.
![Page 6: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/6.jpg)
Faults
Types of “faults” Short-circuit faults Open-circuit faults Faults are detected by relays(automatically)
and faulty section is isolated by circuit breakers.
The combination of relays and circuit breakers is known as “Protective system”.
![Page 7: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/7.jpg)
Content of Automatic switchgear
Current and voltage transformer Relays Circuit breakers Lightning arresters(or “Surge diverter”) Isolators(or “Disconnecting switch”) Fuse
![Page 8: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/8.jpg)
Main Protection Requirements Reliability
Selectivity
Speed
Sensitivity
![Page 9: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/9.jpg)
Current Transformer(CT)
A current transformer (CT) is used for measurement of alternating electric current.
When current in a circuit is too high to apply directly to measuring instruments, a current transformer produces a reduced current accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments.
Current transformers are commonly used in metering and protective relays in the electrical power industry.
![Page 10: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/10.jpg)
Current Transformer contd…
![Page 11: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/11.jpg)
Potential Transformer(PT)
Potential transformers (PT) (also called voltage transformers (VT)) are a parallel connected type of instrument transformer.
They are designed to present negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to enable accurate secondary connected metering.
![Page 12: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/12.jpg)
Potential Transformer contd… It gives the reference voltage to the
Relay for Over-voltage or Under-voltage Protection.
![Page 13: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/13.jpg)
Introduction To Relay
A Relay is a logical elements which process the inputs(mostly voltage and currents) from the system and issue a trip decision if a fault within its jurisdiction is detected.
Inputs to the Relays are Current from current transformer(CT) Voltage from voltage transformer(VT)
![Page 14: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/14.jpg)
Relay Panel
![Page 15: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/15.jpg)
Relay contd…
A typical protective Relay
![Page 16: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/16.jpg)
How Do Relays Detect Faults?
When a fault takes place, the current, voltage, frequency, and other electrical variables behave in a peculiar way. For example: Current suddenly increases Voltage suddenly decreases
Relays can measure the currents and the voltages and detect that there is an over-current or an under-voltage or a combination of both.
Many other detection principles determine the design of protective relays.
![Page 17: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/17.jpg)
Basic Elements of Relay
Sensing Element
Comparison Element
Control Element
Relay
To trip or signal circuit(CB)
![Page 18: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/18.jpg)
Three-Phase Diagram of the Protection
CTs
VTs
Relay
CB
Control
Protected Equipment
![Page 19: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/19.jpg)
Advantages of Relay
Maximum flexibility Provide multiple functionality Self checking and communication
facility It can be made adaptive for any
system
![Page 20: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/20.jpg)
Circuit Breaker(CB)
Circuit breakers are an automatically operated electrical devices, design to close or open contact members, thus closing and opening an electrical circuit under normal or abnormal conditions.
It operates on relays command. It handles the large voltage and
current.
![Page 21: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/21.jpg)
Operating Principle of a Circuit Breaker
A circuit breaker consists of two contacts namely “fixed” and “moving contacts” which touches each other under normal condition i.e. when circuit breaker is closed.
Whenever a fault occurs(detected by relay), the trip coil get energized, the moving contacts get pulled by some mechanism and therefore, the circuit breaker is opened and circuit is broken.
![Page 22: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/22.jpg)
Various Types of Circuit Breaker CBs are categorized based on the
intrrupting medium used.1. Air-Break Circuit Breakers (ACB)2. Oil Circuit Breakers (OCB)3. Vacuum Circuit Breakers (VCBs)4. Air-Blast Circuit Breakers (ABCB)5. SF6 Circuit Breakers
![Page 23: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/23.jpg)
Circuit breaker contd…
An Oil Circuit Breaker SF6 Circuit Breaker
![Page 24: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/24.jpg)
Lightning arrester(Surge Diverter) The device or equipment used for the
protection of the power system against voltage surge is called “surge diverter” or “lightning arrester”.
![Page 25: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/25.jpg)
Isolators
Isolators are used to isolate the high voltage from flow through line into the bus. It allows only needed voltage and rest is earth by itself if required.
Isolator
![Page 26: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/26.jpg)
Conclusion
The objective of the protection devices(system) is to keep the power system stable by isolating only the components that are under fault, while leaving as much of the network as possible.
Now a days the Substation Protection System is fully automatic.
![Page 27: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/27.jpg)
References
Power system protection and switchgear by Badri Ram TMH publication.
Fundamentals of Power system protection by Yeshwant G. Paithankar, S.R. Bhide.
Electrical Power system by A Wright. Wikipidia
![Page 28: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/28.jpg)
Questions…
?
![Page 29: Substation protection devices](https://reader035.vdocuments.net/reader035/viewer/2022062310/5887b2031a28ab817a8b4a37/html5/thumbnails/29.jpg)
Thank you...