summary of content - jicable hvdc'13 · summary of content page ... iet, the institution of...

144
Summary of Content Page Organizers / Technical Support Honorary Committee, Steering Committee Organization Committee, International Scientic and Technical Committee General objectives and topics Audiovisual technical presentations Technical visits V1: Visit of the primary substation “Boule” V2: Visit of the static reactive power compensator in Nanterre V3: Visit of the R&D site «EDF Lab les Renardières » Tutorials T1: Impact of EMF on current ratings and cable systems T2: Guide for rating calculations of HV cables T3: Guidelines for submarine cable projects T4: Issues related to long HVAC cables T5: Electrical modelling of MV cables and off-line diagnostic Jicable‘15 Prize Young researchers contest Receptions International technical exhibition General information Dates and venue Ofcial languages Abstracts Proceedings Badges Practical Information Meals Car parking WiFi Space Insurance Useful tips Hotel reservations Getting to Versailles CD-ROM sales Sightseeing suggestions Addresses to note Conference Welcome Desk opening hours

Upload: vuongkhanh

Post on 08-Jul-2018

228 views

Category:

Documents


0 download

TRANSCRIPT

Summary of Content

Page

Organizers / Technical Support Honorary Committee, Steering Committee Organization Committee, International Scientifi c and Technical Committee General objectives and topics Audiovisual technical presentations Technical visits V1: Visit of the primary substation “Boule” V2: Visit of the static reactive power compensator in Nanterre V3: Visit of the R&D site «EDF Lab les Renardières » Tutorials T1: Impact of EMF on current ratings and cable systems T2: Guide for rating calculations of HV cables T3: Guidelines for submarine cable projects T4: Issues related to long HVAC cables T5: Electrical modelling of MV cables and off-line diagnostic Jicable‘15 Prize Young researchers contest Receptions International technical exhibition General information Dates and venue Offi cial languages Abstracts Proceedings Badges Practical Information Meals Car parking WiFi Space Insurance Useful tips Hotel reservations Getting to Versailles CD-ROM sales Sightseeing suggestions Addresses to note

Conference Welcome Desk opening hours

Jicable’159th International Conference on Insulated Power Cables

Paris - Versailles - France - June 21st - 25th 2015

Organization

SEE, Société de l’Électricité, de l’Électronique et des Technologies de l’Information et de la Communication

CIGRE, International Council on Large Electric Systems

SYCABEL, Syndicat Professionnel des Fabricants de Fils et Câbles Électriques et de Communication

ERDF, Électricité Réseau Distribution France

RTE, Réseau de Transport d’Électricité

SERCE, Syndicat des Entreprises de Génie Électrique et Climatique

With the technical and scientifi c support of

AEIT, Federazione Italiana di Elettrotecnica, Elettronica, Automazione, Informatica e Tele-comunicazioniAESIEAP, Association of the Electricity Supply Industry of East Asia and the Western Pacifi c*AFNOR, French Standardization SystemAPUA, Association of Power Utilities of Africa*ASEFA, Certifi cation d’Appareillage ElectriqueAUE, Arab Union of ElectricityCAFELEC, Confédération Africaine d’ÉlectricitéCENELEC, European Committee for Electro-technical Standardization*CIGRE, International Council on Large Electric Systems (International and French National Committee)CIRED, International Conference on Electricity DistributionCIS, Electric Power Council, RussiaCOMELEC, Comité Maghrébin de l’ÉlectricitéELECTROSUISSEENTSO-E, European Network of Transmission Systems Operators for ElectricityEUREL, Convention of National Societies of Electrical Engineers of EuropeEURELECTRIC, The Union of the Electricity Industry*EUROPACABLE, The European Confederation of National Associations of Manufacturers of Insulated Wire and CableFENELEC, National Federation of Electricity, Electronics and Renewable Energies, MoroccoFNCCR, Fédération Nationale des Collectivités Concédantes et Régies*HAPUA, Head of ASEAN Power Utilities / Authorities*IEC, International Electro-technical Commission

IEEE DEIS, Dielectrics and Electrical Insulation Society *IEEE ICC, Insulated Conductors Committee*IEEE, French SectionIET, The Institution of Engineering and Technology*ÖVE, Österreichischer Verband für ElektrotechnikPPA, Pacifi c Power AssociationProspective 21OO, Preparing the Future, FranceSEE, Société de l’Electricité, de l’Electronique et des Technologies de l’Information et de la CommunicationSRBE/KBVE, Société Royale Belge des ElectriciensUFE, Union Française de l’ElectricitéUTE, Union Technique de l’ElectricitéVDE, Verband der Elektrotechnik, Elektronik, Informationstechnik e.V. / Deutscher Elektrotechniker* (to be confi rmed)

Committees

Honorary CommitteeRay AWAD, Chairman of Jicable’11 ISTC (International Scientifi c and Technical Committee), CanadaKen BARBER, Chairman of Jicable’07 ISTC, AustraliaHorst BLECHSCHMIDT, Chairman of Jicable’95 ISTC, GermanyRobert-Pierre FAUDEL, Chairman of Jicable’87 & Jicable’91 Steering Committee, FranceZensuke IWATA, Chairman of Jicable’03 ISTC, Nuclear Fuel Industries, Ltd, JapanRoland NATALINI, Chairman of Jicable’99 Steering Committee, FranceRobert ROSEVEAR, Chairman of Jicable’99 ISTC, Southampton Dielectrics Consultants Ltd, United-KingdomRalph SAMM, Chairman of Jicable’91 ISTC, USAPierre-Henri SEDES, Chairman of Jicable’95 Steering Committee, FranceRoger TELLIER, Chairman of Jicable’84 & Jicable’87 ISTC, FranceBruno THOMAS, Chairman of Jicable’03 Steering Committee, France

Steering Committee

ChairmanLaurent TARDIF, SYCABEL

MembersPhilippe ADAM, CIGREHugues de GROMARD, Club JicableLucien DESCHAMPS, Prospective 21OOMichel DUBREUIL, RTEJacques FILLOUX, SERCEFrançois GERIN, SEEAnnie KIRCHE, ERDFRégis PAUMIER, SYCABEL

Organization Committee

ChairmanLucien DESCHAMPS, Prospective 21OO

SecretaryBernard DALLE, BMD Consulting

MembersPhilippe ADAM, CIGREMellyha BAHOUS, SEEPhilippe BARATON, EDF R&D / ERDFSylvie BARBAZANGES, Prysmian Câbles et Systèmes FrancePierre-Marcel DEJEAN, Prysmian Câbles et Systèmes FranceVera DUBEUX-TORRES, Prospective 21OOJacques FILLOUX, SERCEPhilippe GIFFARD, SYCABELJACQUES HORVILLEUR, SEEJean-Michel LEQUEUX, Epistol-ConsultFlore MANIER, SEEMax MUSQUIN, Silec Cable /General CableSophie ROYNETTE, RTEHoussam TANZEGHTI, EDF - R&DBéatrice VINCLER, NEXANS

International Scientifi c and Technical Committee

ChairmanMarco MARELLI, Prysmian, Italy

Vice-ChairmenPierre ARGAUT, CIGRE, B1 CommitteeKenneth BARBER, NAN Electrical Cable, AustraliaThomas C. CHAMPION III, Georgia Tech NEETRAC, USA*Francis KRÄHENBÜHL, Nexans Suisse SA, SwitzerlandPaul PENSERINI, RTE / CNER, FranceMozart de SIQUEIRA CAMPOS ARAUJO, Brennand Energia, BrazilHideo TANAKA, VISCAS Corporation, JapanLisheng ZHONG, Xi’an Jiatong University, China

SecretaryJean BECKER, Nexans / Sart Consult, Belgium

MembersMarcelo de Araujo ANDRADE, Prysmian, ItalyRay AWAD, Hydro-Québec TransEnergie, CanadaRohini BHATTACHARYYA, Ducab, United Arab EmiratesWillem BOONE, KEMA Nederland BV, The NetherlandsMichael CHANG, Nexans, ChinaAnthony FALCONER, Aberdare Cables, FranceAlain GILLE, Verbraeken Construction, BelgiumErnst GOCKENBACH, Leibniz Universität Hannover, GermanyStanislaw GUBANSKI, Chalmers University of Technology, SwedenUnnur Stella GUDMUNDSDOTTIR, DONG Energy, DenmarkNigel HAMPTON, Georgia Tech NEETRAC, USAThomas HJERTBERG, Borealis AB, SwedenSeung-lk JEON, LS Cable, KoreaMarc JEROENSE, ABB AB, SwedenJa Yoon KOO, Hanyang University, KoreaKieron LEEBURN, CBI Electric, African Cables Ltd, South AfricaDavid LINDSAY, ABB, USA*Mohamed MAMMERI, Silec Cable, FranceAndrea MANSALDO, Eirgrid Ireland*Juan Manuel MAXIMO-LEON, Conductores Monterrey, S.A, MexicoHans A. MAYER, Consultant, AustraliaPierre MIREBEAU, Nexans, FranceRachel MOSIER, Power Delivery Consultants, USAN. MURUGESAN, Central Power Research Institute, India*Petru NOTINGHER, Université Montpellier 2, CNRS, FranceHarry E. ORTON, Orton Consulting, CanadaRonald PLATH, Ing.-Büro HPS, GermanyAleksandra RAKOWSKA, Tu Poznan Univ. of Technology, PolandJean-Louis RAUD, SERCE, FranceDirk RITTINGHAUS, Energycableconsult, GermanyRobert ROSEVEAR, Southampton Dielectric Consultant Ltd, UKJacint Rovira, Groupo General Cable Sistemas SA, SpainIgnacio Manuel RUIZ, Edenor, ArgentinaCandelario de J. SALDIVAR CANTU, Viakon Conductores Monterrey, Mexico

Jan SCHUTTEN, Prysmian, The NetherlandsJoão José dos SANTOS OLIVEIRA, Consultor de Redes Subterraneas, BrazilNgapuli Irmea SINISUKA, Institut Teknologi Bandung, IndonesiaJohn SMITH III, General Cable Corporation, USASteve SWINGLER, University of Southampton, UKVictor SYTNIKOV, R&D Center @FGC UES, RussiaRoger TAMBRUN, ERDF, FranceGilbert TEYSSEDRE, Laplace, Université P Sabatier, CNRS, FranceJean-Charles TOURAINE, Prysmian Câbles & Systèmes, FranceSidnei UEDA, Nexans, BrazilAriel VALDENEGRO, Universidad de Chile, ChileUberto VERCELOTTI, MPD TCE CESI Spa, ItalyLiming YANG, State Grid Electric Power Research Institute, ChinaVitaliy YAROSLAVISKIY, Cable Technology Lab., Inc., USAErnesto ZACCONE, Prysmian Powerlink S.r.l., ItalyWalter ZENGER, USI, USADongping ZHANG, Tennet Offshore GmbH, GermanyTiebin (Tom) ZHAO, Electrical Power Research Institute, USA* to be confi rmed

General objectives and topics

What is Jicable’15 ?Jicable’15 is an international forum for the exchange of information in the fi elds of research, industrial development, installation, operation and diagnosis relating to AC and DC insulated power cables and their accessories from low voltage and special cables up to ultra-high voltage cables and new technology cables.

Why is Jicable’15 important ?Insulated power cables are increasingly used in electrical power transmission and distribution networks. This is due to the signifi cant progress achieved in the development of new technologies with higher performances, and motivated by increasing environmental pressure. Cables are recognised as a reliable means for the transportation and distribution of electrical energy.Jicable’15 will allow in-depth analysis of the State-of-the-Art and future perspectives: new materials, evolution in technologies, improvements in manufacturing process, improvement of maintenance policies and remaining life estimation, lessons learned from service experience, dielectric phenomena, thermal and thermo-mechanical behaviour, … new innovative technical solutions for high power transmission: new superconductive materials as well as a closer look at major submarine cable projects connecting High Voltage networks in many countries.

Who will be taking part in Jicable’15 ?As for the 8 earlier Jicable conferences held between 1984 and 2011 (748 delegates from 47 countries at Jicable’11), Jicable’15 will prove very useful to the following segments of the cable industry: researchers, engineers, decision-makers, raw materials suppliers, manufacturers, consultants, installers and users.

The following topics will be discussed:1. Materials, New Materials and Ageing Assessment in AC and DC2. Cables and Accessories Design - Modelling3. Testing Methods: Electrical and not Electrical4. Cables, Environment and Sustainable Development5. Diagnosis, Maintenance, Remaining Life Estimation and Management6. Economy of Cable Systems7. LV and MV Cable Systems8. HV and EHV AC Cable Systems9. HVDC Cable Systems10. Submarine Cable Systems11. Cables for the Future12. Industrial and Special Cables13. Technical challenges encountered with cable systems

Audiovisual technical presentations

The Jicable’15 Organization Committee has made it possible for research laboratories and companies to hold audiovisual presentations during the conference.Projections will take place during the conference according to a program which will be issued each day.

Technical visits

Thursday, June 25th 2015 - 09:00

Technical Visit V1Visit of the primary substation “Boule”

Technical Visit V2Visit of the static reactive power compensator in Nanterre

Technical Visit V3Visit of the EDF R&D site «Laboratoires des Renardières »

Technical Visit V1Visit of the primary substation “Boule”The 225/20 kV Boule substation, which will be in service in late 2015, will serve a dense urban area located in the western suburbs of Paris. Built to meet the load growth, it will also help secure the supply of the business district ‘La Défense’. Located on a 2300 m2 plot of land, it will host, in 2017, three 225 kV / 20 kV transformers of 70 MVA each. Ultimately, it will feed sixty underground connections. All of the HV and MV installations are located in a 5-level building. This building was the subject of an extensive architectural study in order to best integrate in the urban environment.Duration : half dayCapacity : 30 peopleFee : 60 €, including transport.

Technical Visit V2Visit of the static reactive power compensator in NanterreThe static reactive power compensator in Nanterre is an installation that controls voltage by injecting reactive power into the network. This process is particularly required in case of an urban dense underground network involving inductive power injection in order to compensate the capacitive behaviour of the cables. This equipment is both adaptable and fast. It avoids the risk of voltage collapse in a few tenths of a second. It ensures the operating safety of the power system and guarantees the quality of supply. The equipment is one of the innovations now being implemented in strategic substations. It contributes to making electricity networks smart and effi cient. Duration : half dayCapacity : 30 peopleFee : 60 €, including transport.

Technical Visit V3Visit of the EDF R&D site «Laboratoires des Renardières »The EDF R&D’s site “Les Renardières” in the south of Paris is one of the three research sites of the group EDF in France. This technical visit is an opportunity to visit laboratories such as the “EDF Networks Lab” and the “Concept-GRID”.

The EDF Networks Lab represents all EDF R&D’s testing facilities for all electrical system equipment. These tests cover the entire range of electrical tests from low to high voltage.The Concept Grid is a unique experimental platform to support and anticipate the evolution of electrical systems. This set of facilities operates under medium and low voltage and allows a wide range of experiments making Concept Grid a fi rst rate tool for preparing tomorrow’s networks.Its unique design places it mid-way between laboratory tests and experiments in the fi eld. Concept Grid makes it possible to conduct complex testing campaigns, in complete safety that would be impossible to perform on a real network.Duration : 1 dayCapacity : 40 peopleFee : 95 €, including transport and lunch.

Tutorials

Five high level tutorials will be given in english by professors on Sunday, June 21st 2015 - 13:30 - 17:00 (break from 15:00 to 15:30), for a limited number of people.

Tutoriel T1 Impact of EMF on current ratings and cable systems

Tutoriel T2 Guide for rating calculations of HV cables

Tutoriel T3 Guidelines for submarine cable projects

Tutoriel T4 Issues related to long HVAC cables

Tutoriel T5 Electrical modelling of MV cables and off-line diagnostic

Tutorial T1:Impact of EMF on current ratings and cable systemsby Harry Orton, Consulting Engineers International, CanadaTutorial T1 presents guidelines for managing the rating of a HV underground power cable electric system when magnetic fi eld mitigation techniques are added to the system. The addition of any mitigation device may modify the ambient conditions surrounding the cables so examples are provided in the tutorial to give good technical solutions leading to practical installations. Extensive case studies will be discussed. A summary table is provided to assist with the most judicious selection of the shielding method as well as economical evaluation of investment costs. Also the cost of additional losses and maintenance of the mitigation device is discussed.Tutorial organized in cooperation with the CIGRE Study Committee B1.

Tutorial T2 Guide for rating calculations of HV cablesby Frank H. de Wild, DNV GL, NetherlandsTutorial T2 is based on very recent CIGRE work which includes the current rating of insulated power cables: directly buried, submarine and in-air installations are considered in detail, addressing problems with establishing the ampacity of both new and existing power cables. In the tutorial, three major topics will be considered:Starting points for rating calculations.Guide for calculating the current rating in situations which are not fully described in the existing IEC standards. Tools and techniques available for performing cable rating calculations.

This tutorial will give the participant the most recent overview of all possibilities and impossibilities, do’s and don’ts, solutions and remaining ‘gaps’ regarding the complete topic of underground power cable current rating.Tutorial organized in cooperation with the CIGRE Study Committee B1.

Tutorial T3Guidelines for submarine cable projectsbyChristian Jensen, Manager Projects, Energinet.dkTutorial T3 presents guidelines concerning many aspects of submarine cable projects and in particular for offshore generation. Main topics are offshore surveys for consenting and installation purposes, system design of cable connections, cable design, cable installation, testing, maintenance and dynamic cables for fl oating generation. Examples are included. The tutorial can be used as an introduction to the subject and a basis for further discussions regarding submarine cable issues.Tutorial organized in cooperation with the CIGRE Study Committee B1.

Tutorial T4Issues related to long HVAC cablesbyFilipe Miguel Faria da Silva, Faculty of Engineering, Aalborg, Denmark* and Ken Barber, Nan Electric Cable, Australia**

1. Power System Technical Performance Issues* The fi rst part of Tutorial T4 describes system technical performance issues related to power systems with long AC cables. The study areas are divided into planning, system impact and equipment design. The presentation includes examples and explanations such phenomena occurring as a result of various system operations, guidelines for simulation, interpretation of the results, possible mitigation measures, recommendations on modelling and results measurements performed on the 100 km long Horns Rev 2 AC cable.

2. Implementation issues** The second part of Tutorial T4 will start with a practical defi nition of a long length AC cable system and reasons for the recent signifi cant growth in the demand for such systems. Then, it will address the modern developments which have occurred in cable and accessory design as well as installation techniques which have made this possible. The various challenges for practical implementation such as matching ratings, protection systems, controlling EMF, reactive compensation, sheath bonding, directional drilling, rights of way, testing, monitoring and reliability of supply will be addressed. Finally some practical examples of more than 50 long length AC cable systems which have been identifi ed will be discussed to highlight some of these issues.

Tutorial organized in cooperation with the CIGRE Study Committees C4 and B1.

Tutorial T5Electrical modelling of MV cables and off-line diagnosticByMinh Nguyen-Tuan* and Thierry Espilit**, Electricité de France, R&D, FranceThe development and the asset management of underground and submarine links go along an increasing demand for theoretical and experimental studies of the cables behaviour. The purpose of this tutorial is to provide elements both in terms of fi ne electrical modelling, and in terms of measurements for off-line diagnostic of MV cable links.

1. Electrical modelling of cables* In the fi rst part of the tutorial, we will present cable models, which must be carefully chosen to get reliable simulation results.

The following topics will be addressed:Existing models, for steady-state and transients studies;Cable systems electrical characteristics;

Limitations of existing models and areas for improvement.

2. Off-line diagnostic** In the second part, we will present diagnostic measurement methods for MV underground links. These methods have been specifi cally developed in order to prevent short time failure and to rank types of cable sections for network renewal operations.

The following topics will be addressed:Methods based on tangent delta and partial discharges measurements; Limitations of currently used criteria;Possibility of adapting the diagnostic operations based on the characteristics of diagnostic systems available.

Jicable’15 Prize

The Jicable’15 prize will be awarded to the authors of the best communication 2015, by an ad hoc jury and presented on stage at the end of the conference during the Closing Session.(The Jicable’11 award to Mrs Blandine Hennuy)

Young researchers contest

The Organizers of Jicable’15 are setting up a Young Researchers Contest to encourage the participation of students and young researchers and to promote professions of the cable. The call for papers was sent to engineering schools and universities. It was based upon the same 13 topics as for the conference. 25 communications were accepted and will compete. The authors of the three best communications will receive prizes, respectively 1500 € fi rst prize, 1 000 € second prize and 500 € (third prize).Accepted papers will appear in the Jicable’15 Proceedings.

Receptions

Welcome Cocktail at Versailles Congress CentreSunday, June 21st 2015 from 18:30 to 20:00The Welcome Cocktail will take place after the “Welcome Lecture: Brazil’s situation in terms of energy - Challenges and perspectives” given by Josias Matos de Araujo, Vice President CNB CIGRE, Director of regulation, Eletrobras, Brazil.

The Jicable «Soirée» at Versailles Academy of Equestrian ArtsOn Tuesday, June 23rd 2015 from 18:30 to 22:30:Jicable will celebrate it’s 30th anniversary with the organization of the Jicable’15 “Soirée”, at Versailles Academy of Equestrian Arts.At two-minute walk from the Congress Centre, in the exceptional setting of the “Grandes Écuries” (royal stables) of the Château de Versailles, you will enjoy a brilliant equestrian show choreographed by Bartabas for the riders of the Versailles Academy of Equestrian Arts.The show ‘La Voie de l’Écuyer Opus 2015’ (‘The Way of the Rider Opus 2015’) will be followed by an open-house tour of the royal stables, remarkable for their size and the nobility of their architecture.Then the cocktail party will be served on the golden sand of the horse riding arena, a showcase of wood and mirrors, subtly lit by Murano glass chandeliers.

(Photo Agathe Poupenay / Photoscene)

International technical exhibition

An Exhibition will be held from June 22nd to 25th 2015 inside the Congress Centre of Versailles in the

heart of the Conference area.Around 40 exhibitors will show materials, design, manufacturing, tests, laying and operation of polymer insulated power cables.Access to the exhibition will be reserved for Jicable’15 delegates and holders of invitations delivered by the exhibitors.Societies participating at the Jicable’15 exhibition:

ABB HAEFELY HIPOTRONICS PFISTERER FRANCE SAS

ALROC HIGH VOLTAGE INC PHENIX SYSTEMS AG

AP SENSING HIGH VOLTAGE PARTIAL DISCHARGE POURTIER S.A.S

ARTOFIL HIGH VOLTAGE TEST SYSTEMS

POWER DIAGNOSTIX SYSTEMS

B2 ELECTRONIC GMBH HIGHVOLT PRÜFTECHNIK PRYSMIAN GROUP

BAUR PRUF IMERYS GRAPHITE & CARBON RTE

BRUGG CABLES KINECTRICS SCAPA Group PLC

CYME INTERNATIONAL LIOS TECHNOLOGY SENSORNET

DNV GL / KEMA MEGGER SICAME

DUCAB MOHAUPT SMEETS-LOYPOS

EDF R&D / EDF CIST NEXANS STRI

EMELEC ELEKTRIK NKT CABLES GMBH UTILX EUROPE

EVERGREEN HIGHVOLTAGE OMICRON WIRESCAN

GENERAL CABLE OMNISENS

H&R CHEMPHARM ONSITE HV

General Information

Date and venueJicable’15 will be held at Versailles Congress Centre (close to Paris):10 rue de la Chancellerie 78000 Versailles - France.Phone : + 33 1 40 68 22 22Technical Sessions, Invited lectures, Tutorials, the audiovisual presentations and the exhibition will be held inside the Congress Centre from June 21st to 25th 2015.The only activities organized outside the Congress centre will be the Jicable’s Soirée and the Technical Visits.

Offi cial languagesThe offi cial languages at Jicable’15 will be French and English.Simultaneous translation will be provided in all two languages in rooms A & B for all sessions (simultaneous translation shall not be available in rooms C, D, and E).

Texts of the AbstractsThe texts of the abstracts are available from the Jicable’s website.

ProceedingsOn arrival at the Welcome Desk, each participant will receive a conference bag with a digital tablet containing the text of communications included in the program.The CD-ROM Jicable’s Archives with all proceedings from the 8 former Jicable’s Conferences from 1984 to 2011 will be on-sale at reduced price when bought with a registration (see § registration).

BadgesAn admission badge will be delivered to each participant, giving access to the conference sessions, to the audiovisual presentation and to the exhibition. It must be worn throughout the conference period.

Practical Information

MealsAll attendees will fi nd in the conference bag a list of restaurants proposing menus at a wide range of prices around the Congress Centre.

Car parkThere is a very large car park on the “Place d’Armes”, located closed to the “Château de Versailles” and in front of the Congress Centre.

WiFi spaceWiFi will be available for wireless internet users.

InsuranceThe organizers cannot be held liable for any personal accident , damage, the loss of any personal property, whatever the cause. Participants should therefore make their own insurance arrangements.

Useful tipsIn the month of June, the temperature in Versailles is usually around 20°C with a probability of rain showers.In France, the electric current is 220 V / 50 Hz. It is advised to consider the use of an electric adaptor.

Hotel bookingsAs the conference will take place at a time when the demand for hotel accommodation in Paris and Versailles is rather high, participants are advised to make their reservation as soon as possible.Voyages C. MATHEZ VIAZUR, the travel agency appointed by the organizers, has made special block bookings of rooms at reduced rates for Jicable’15 attendees, both in Paris and in Versailles.To make your hotel reservation, please contact directly:

Voyages C. MATHEZ VIAZURPascale CASSAIGNE124 Bis, Avenue de Villiers75017 Paris - France

Tel: +33 1 43 18 28 25Fax: +33 1 43 18 28 [email protected]: www.matheztravel.com

Getting to Versailles

From Roissy-Charles de Gaulle Airport:By taxi: Approximate cost 90 € plus 15 € night additional costBy metro: Take RER express train line B, direction St-Rémy-les-Chevreuse, change at St-Michel-Notre-Dame onto an RER line C and get off at Versailles Château - Rive Gauche (300 m from the Palais des Congrès). Approximate cost 15 €.

From Orly Airport:By taxi: Approximate cost 60-70 €By metro: Take the Orlyval metro link, change at Antony and get onto an RER express train line B , direction Aéroport Roissy, change at St-Michel-Notre-Dame and get onto the RER line C. Get off at Versailles Château - Rive-Gauche (300 m from the Palais des Congrès). Approximate cost 15 €.

From Paris:By Suburban train: Take the RER line C express metro and get off at Versailles Château - Rive Gauche (300 m from the Palais des Congrès). Approximate cost 4.35 €.By train: From Paris Montparnasse station, get a train towards “Plaisir Grignon” or “Chartres” and get off at “Versailles Chantiers” (about 1 km from the “Palais des Congrès”). Approximate cost 4,35 €, duration of the trip 16 minutes From Paris St Lazare station or La Défense “Grande Arche” take a train toward Versailles “Rive Droite” (about 1 km from the Palais des Congrès, duration of the trip 35 minutes).

By road:GPS: 48.8013155 / 2.1253549000000476Take one of the three motorways:Western motorway A 13, exit at “Versailles Chateau” or “Le Chesnay / Versailles Centre/ Marly le Roi”.Western motorway A 86, exit at “Versailles Chateau”.Western motorway A 12, exit at “Le Chesnay / Versailles Centre / Marly-le-Roi”.

CD-ROM Sales

CD-ROM Sales: The CD-ROM “Jicable’s Archives” containing all proceedings for the 8 former Jicable’s Conferences (more than 1200 communications from 4000 authors). This CD-ROM is supplied with a search engine allowing plain text researches from within the paper text - a quick and easy way to get the best from the archives. Normal price 200 €, 160 € if bought with a registrationCD-ROM of Jicable-HVDC13 European Seminar on materials for HVDC cables and accessories: Performance, Modelling, Testing, Qualifi cation; the conference with texts and authors presentation - normal Price 90 €, sold 60 € with a registrationSpecial price for both CD-ROM, The Jicable’s Archives and Jicable-HVDC13 normal price 290 €, sold 200 € if bought with a registrationCD-ROM of the Jicable’s Workshops, WETS’11, WETS D’11 and CABOS’11, sold 50 € (3 workshops)

Sightseeing suggestions

Created by King Louis XIVth of France to act as the vehicle for his reign, Versailles is a New Town and a model of urbanism worldwide.Its rich architectural and urban heritage makes Versailles a unique experience. Take an exploratory stride along the roads through the neighbourhoods brimming with beautiful monuments, artistic and cultural centres and parks.Versailles Tourist offi ce: http://www.versailles-tourisme.comTake advantage of your venue in Paris to visit the capital, which offers high historical and cultural areas, worldwide renowned monuments, museums and picturesque places.Practical information about Eiffel tower, Notre-Dame-de Paris cathedral, the Sacré Coeur, Arc de Triomphe, The Louvre and many other unmissable areas is available at:Paris tourism offi ce: http://www.parisinfo.com/To help you discover Paris and the area, Cityrama Paris Vision offers a wide range of excursions on climatized buses from their agency located in the Paris centre, or on minibuses from and to your hotel. They will take you to visit the capital and its surroundings, and discover Paris by night with many activities, illuminations, cruisers on the river Seine, cabarets…If you need any information, please contact directly:

Cityrama Paris Vision2 place des pyramides / 214, rue de Rivoli75001 ParisCentral reservation: +33 (0)1.44.55.61.00Web site: http://www.pariscityvision.com

Addresses to note

Before the ConferenceJicable’15 Registrations:SEE Jicable’15 - 17 rue de l’Amiral Hamelin75783 Paris Cedex 16 - FrancePhone: +33 1 56 90 37 11 or 03Fax: +33 1 56 90 37 19Site Web: http://www.jicable.org/2015/e-mail: [email protected]

During the ConferenceAll services will be transferred to:Palais des Congrès de Versailles10, rue de la Chancellerie78000 Versailles - FrancePhone: +33 1 30 97 89 01

Hotel bookingsVoyages C. MATHEZ VIAZURMrs Pascale CASSAIGNE124 Bis, avenue de Villiers75017 Paris - FrancePhone: +33 (0) 1 43 18 28 25Fax: +33 (0) 1 43 18 28 29Email: [email protected] web: www.matheztravel.com

Sightseeing reservationsCityrama Paris Vision2 place des Pyramides / 214, rue de Rivoli75001 Paris - FranceCentral reservation: +33 1 44 55 60 00Web site: http://www.pariscityvision.com

Conference Welcome Desk Opening Hours

Saturday June 20th 16:00 - 18:00Sunday June 21st 10:00 - 18:30Monday June 22nd 08:00 - 18:30Tuesday June 23rd 08:00 - 18:00Wednesday June 24th 08:00 - 18:00

Welcome lectureBy

Josias Matos de Araujo, (biography) Vice President CNB CIGRE, Director of Regulation, Eletrobras, Brazil

Brazil´s situation in terms of energy – Challenges and perspectives

Brazil has the largest electricity market in South America. The country has the largest capacity for water storage in the world being highly dependent on hydroelectricity generation capacity, which meets over 80% of its electricity demand. This dependence on hydropower makes Brazil vulnerable to power supply shortages in drought years. As a result of the ongoing drought, Brazil has constructed additional short-term natural gas-fi red generation in order to ease the burden on the nation´s hydro-electric dams, with reservoir levels falling to near critical capacity. Reservoir levels in the Southeast and Central West regions of the country were roughly half expected levels for the time of 2014, resulting approximately in 6000 MW of additional thermal capacity being put onto the grid in that region.The Brazilian interconnected system which accounts for about 98% of the Brazilian electricity market has an installed capacity of near 134 GW, with the hydro system responsible for 74% of the total installed capacity. The fi gure 1 shows the structure of the domestic supply electricity in Brazil in 2013. It can be observed that Brazil presents and electricity matrix predominantly renewable, and the domestic hydraulic generation accounts for 64 % of the supply. Adding imports, which are also mainly from renewable sources, it can be stated that 79% of electricity comes from renewable sources.The interconnect system is based on 125.000 km of transmission lines ranging from 230 Kv to 750 kV and dc links connecting the binacional Itaipu power plant (14000 MW) and Santo Antonio / Jirau power plant (6300 MW) to national grid. The Brazilian Transmission System is showed in the fi gure 2

Challenges and Perspectives

With yearly average global irradiance levels of 5.5 – 6.0 kWh/m2/day, Brazil has a high potential for the use of solar energy. Recent targets from the government for 1,400 MW of distributed solar generation by 2022 have accelerated market development, with approximately 122 MW of utility- scale solar projects being awarded long-term power purchase agreements in the 2013 federal energy supply contract auction. Brazil has a lot of challenges and perspectives for the future in the area of solar energy both in research and development to expand their sources of renewable energy.Brazil has a potential for wind power of 143 GW. At the end of 2012, Brazil had 2.5 GW of installed wind capacity, enough to power four million households, accounting for 2 percent of national electricity consumption. Brazil currently has over 7 GW of wind power projects in the pipeline to be delivered by 2016, and the government’s Decennial Energy Plan (PDE 2021) sets a 16 GW wind installed capacity goal by 2021. The local Brazilian wind market is forecast to grow at over 2 GW annually.Major biomass sources are fi rewood, sugar cane products and other agricultural waste. Sustainable biomass could have a potential of 20 GW.In 2013 Brazilian Government has launched the Inova Energia Program (the “Inova Program”),

which provides a series of subsidies and other incentives to assist Brazilian companies and technology institutes to develop and commercialize innovative technologies for the power sector, including solar power, smart grids and energy-effi cient vehicles.Eletrobras, one of the most important energy companies in Brazil, has an important role in the growing and expansion of the Brazilian generation and transmission. Eletrobras was included in the Sustainability Yearbook of 2015 of the RebecoSAM, an international investment company with a specifi c focus on sustainability investments, which is based in Zurich, Switzerland and considers economic, environmental and social criteria in its investment strategies. Eletrobras has contracted approximately 11,9 GW, individually or through purpose special company (SPE), under construction or to be started in operation. These projects and others under construction in Brazil will incorporate to Brazilian electric matrix, by 2019 approximately 22 GW, mostly come from clean energy sources and renewables.The presentation will consider the evolution of Brazilian power system both in transmission and in generation, the various changes in our model as well as all challenges we face to overcome the great issues to interconnect all regions of the country. Long transmission lines and many power plants are necessary to attend our energy consumption growth of 5% a year. So the presentation will show what we are doing in Brazil and in Eletrobras to overcome all these challenges for the next 10/20 years in the electrical sector. In 2013, the Ministry of Mines and Energy (MME) published the Power Expansion Ten Years Plan, which sets out plans for the expansion of the Brazilian power sector

Figure 1 - Domestic Electricity Supply by Source ( EPE 2014)

Figure 2 – Brazilian Interconnected System (Source: ONS)

Invited Lecture C9.iBy

Serge Roques (biography), Emeritus expert, Safran Group, France

Impact of the new electrical architectureof aircraft on insulated power cables

Starting with less than 50 kVA in the 50th’s, the trend to have more and more electrical power on board is continuous and modern commercial air planes need up to 1000 kVA and probably more in the future for next new generation of aircrafts from AIRBUS and Boeing between 2025 to 2030To reduce carbon and NOx emission and fuel consumption, the use of electrical energy on board is offering smart solutions as:

Bleed Less or No Bleed engines Electric Environmental Control Systems Electric ice protection Electrical Thrust reversers Electrical APU Electrical landing gear extension/retraction e-GTS :Green taxiing e-braking: electrical braking Electrical Nose wheel Steering Electromechanical actuators (EMA) for fl ight control surfaces

The more electrical aircraft today, the Boeing 787 (Dreamliner) requires more than 1 Megawatt of available electrical power on board, enough to power between 100 to 150 houses meeting the new electrical domestic requirements.Such growth in electrical power needed on board obliges Aircraft designers to optimize energy generation, distribution by designing de-centralized or semi decentralized electrical architecture, management of electrical consumption using an Electrical Load Management Systems.More Electrical Aircraft (MEA) means also Energy Optimized Aircraft (EOA) with, for example: the introduction of full composite structure (CFRP) on modern Aircrafts as B787 or A 350 XWB.This composite material is impacting the electrical network, introducing the new concept of Current Return Network (CRN) on B787 or Electrical Structural Network (ESN) on A350 XWB.Due to this increase of electrical energy on board and to reduce the weight of electrical cables, higher voltages have been introduced on: B787 (230VAC and +/-270 VDC ) and on A350 XWB ( 230 VAC).These new voltages induce new issues for cable design: partial discharges which could defi nitively damage the insulation and corona effect producing ionization around the cable,.These physical phenomena could lead to lose critical functions such as fl ight controls powered by electrical hydrostatic actuators (named EHA and EBHA with a back up device ) if design of

new insulation is not tackled at the beginning of system designIn addition the PWM (Pulse Wave Management) control function of the bigger electrical motors induces very high and short peaks of voltage inside the cables which stress continuously the insulation.Filtering the electrical noise emitted by these pulse modulation will lead to defi ne new fi ltering cables which will reduce the size, the weight and the heat dissipation of the conventional fi lters like coils and capacitors Protection against arc tracking initiation is also mandatory mainly with the introduction of new CFRP structure which could be severely damaged in case of cable chafi ng against the carbon structure.All new electrical aircrafts are fully electrically controlled, with no more mechanical back-up, that means that never we shall be in a situation of losing the complete electrical system on board.To address associated risks, the wiring connection has been considered as a System with the introduction of the new EWIS regulation and a distinction between Essential Network and Non Essential Network.EWIS= Electrical Wiring Interconnection SystemEWIS regulation defi ned in FAR 25- Part 25 Subpart H, known in Europe as CS 25 has been released by Sept 5th 2008 .EWIS will consider combination of physical failure induced by electrical installation or electrical technology of components and functional failure coming from the system.The fi rst commercial aircraft implementing this new EWIS regulation is the AIRBUS A350 XWB !All these evolutions means a lot of new exciting challenges for the cable industry where cables are considered as major part of the System supplying power but also data for computerized functions and also for the comfort of passengers with more and more sophisticated In Flight Entertainment Systems (IFE).To save weight several major evolutions have been implemented: higher voltages as mentioned above (230 VAC, +/- 270 VDC) but also copper cladded aluminum conductors for small gauges starting at gauge 24 and aboveThis is not the end of the story and new challenges for the cable industry are: New needs for HVAC and HVDC, Pulse Wave Modulation compatibility, EMI protection, Data on Power/ Power on Data,….. while maintaining safety and robustness at the highest level.

Opening LectureBy

Pierre Bornard, (biography)Deputy CEO of RTE, Chairman of the Board of ENTSO-E

Electricity Transmission Infrastructure: a Key to the Energy Transition

Climate change will be the subject of the COP21 conference to be held in Paris in December under the auspices of the United Nations. The deep transformation of large power systems is essential to meet this challenge. Europe, which aims at being a pioneer in this change, has engaged in an ambitious energy transition, which is only possible by developing renewable energies where natural resources are most available. This requires the deployment of new technology cables and power systems for the offshore wind as well as for interconnections. In a strong regulatory and environmental background, such large-scale projects require improved technological expertise. But a timely grid construction to match the renewable generation also requires to better involve the populations concerned, to fi nd new fi nancing frameworks, and to develop always smarter grids, with a better cooperation with distribution networks.

Conférence d’accueilPar

Josias Matos de Araujo, (biography) Vice President CNB CIGRE, Directeur de la Régulation, Eletrobras, Brésil

Situation du Brésil en termes d’énergie – Dé is et Perspectives

Le Brésil a le plus grand marché de l’électricité en Amérique du Sud. Le pays a la plus grande capacité pour le stockage de l’eau dans le monde étant largement tributaires de la capacité de production d’hydroélectricité, qui se réunit plus de 80% de la demande d’électricité. Cette dépendance sur l’hydroélectricité fait du Brésil vulnérables aux pénuries d’alimentation dans les années de sécheresse. En raison de la sécheresse persistante, le Brésil a construit production supplémentaire au gaz naturel à court terme afi n d’alléger le fardeau sur les barrages hydro-électriques nation’s, avec des niveaux de réservoirs à la capacité de tomber près critique. Les niveaux des réservoirs dans les régions Sud-Est et Centre-Ouest du pays ont été à peu près la moitié les niveaux prévus pour cette période de 2014, résultant en environ 6000 MW de capacité thermique supplémentaire d’être placés sur la grille dans cette région.Le système interconnecté brésilien qui représente environ 98% du marché de l’électricité du Brésil a une capacité installée de près de 134 GW, avec le système hydro responsable de 74% de la capacité totale installée. La fi gure 1 montre la structure de l’électricité nationale d’approvisionnement au Brésil en 2013. On peut observer que le Brésil présente et de la matrice de l’électricité renouvelable prédominante, et les comptes de production hydrauliques domestiques pour 64% de l’approvisionnement. Ajout des importations, qui sont aussi principalement de sources renouvelables, on peut dire que 79% de l’électricité provient de sources renouvelables.Le système d’interconnexion est basée sur 125,000 km de lignes de transmission allant de 230 kV à 750 kV et des liens à courant continu reliant l’usine binacionalItaipu de puissance (14 000 MW) et Santo Antonio centrale / de Jirau (6300 MW) au réseau national. Le système de transmission brésilienne est montré dans la fi gure 2

Dé is et perspectives

Avec des niveaux d’éclairement énergétique mondiales moyennes annuelles de 5,5 à 6,0 kWh / m2 / jour, le Brésil a un fort potentiel pour l’utilisation de l’énergie solaire. Objectifs récents du gouvernement pour 1400 MW de production d’énergie solaire distribuée par 2022 ont accéléré le développement du marché, avec environ 122 MW de projets solaires à l’échelle utilité- étant attribués accords d’achat d’électricité à long terme dans le 2013 Federal Energy contrat de fourniture aux enchères. Le Brésil a beaucoup de défi s et perspectives pour l’avenir dans le domaine de l’énergie solaire à la fois dans la recherche et le développement d’élargir leurs sources d’énergie renouvelable.Le Brésil a un potentiel pour l’énergie éolienne de 143 GW. À la fi n de 2012, le Brésil avait 2,5 GW de capacité éolienne installée, soit assez pour alimenter de quatre millions de ménages, soit 2 pour cent de la consommation nationale d’électricité. Brésil compte actuellement plus de 7 GW de projets éoliens dans le pipeline à livrer d’ici 2016, et le plan de l’énergie décennal du gouvernement (du PDE 2021) fi xe un objectif de capacité installée de 16 GW d’éolien d’ici 2021. Le marché local du vent du Brésil devrait croître au plus de 2 GW par an.

Principales sources de biomasse sont le bois de chauffage, produits de la canne à sucre et autres déchets agricoles. Biomasse durables pourraient avoir un potentiel de 20 GW.En 2013 Gouvernement brésilien a lancé le Programme Inova Energia (le «programme Inova”), qui prévoit une série de subventions et d’autres mesures incitatives pour aider les entreprises brésiliennes et les instituts de technologie pour développer et commercialiser des technologies innovantes pour le secteur de l’énergie, y compris l’énergie solaire, intelligent grilles et des véhicules éconergétiques.rôle dans la croissance et l’expansion de la génération et la transmission du Brésil. Eletrobras a été inclus dans le Sustainability Yearbook 2015 de l’RebecoSAM, une société internationale d’investissement avec un accent particulier sur les investissements en matière de durabilité, qui est basée à Zurich, en Suisse et considère critères économiques, environnementaux et sociaux dans ses stratégies de placement. Eletrobras a contracté d’environ 11,9 GW, individuellement ou par société ad hoc (SPE), en cours de construction ou a commencé en fonctionnement. Ces projets et d’autres en cours de construction au Brésil vont incorporer à la matrice électrique brésilienne, en 2019 environ 22 GW, proviennent principalement de sources d’énergies renouvelables et d’énergie propre.La présentation examinera l’évolution du système d’alimentation brésilienne à la fois en émission et en génération, les divers changements dans notre modèle ainsi que tous les défi s auxquels nous sommes confrontés pour surmonter les grandes questions d’interconnecter toutes les régions du pays. Longues lignes de transmission et de nombreuses centrales sont nécessaires pour participer à la croissance de notre consommation d’énergie de 5% par an. Ainsi, la présentation montrera ce que nous faisons au Brésil et dans Eletrobras pour surmonter tous ces défi s pour les 10/20 prochaines années dans le secteur électrique. En 2013, le ministère des Mines et de l’Énergie (MME) a publié l’Alimentation Extension Dix ans Plan, qui défi nit des plans pour l’expansion du secteur de l’énergie brésilienne.

Figure 1 – Approvisionnement national d’électricité par source ( EPE 2014)

Figure 2 – Réseau interconnecté Brésilien (Source: ONS)

Conférence d’ouverturePar

Pierre Bornard (biography)

Les infrastructures de transport d’électricité: la clé de la transition énergétique

Le changement climatique sera l’objet de la conférence COP21 qui se tiendra à Paris en décembre sous l’égide des Nations Unies. La transformation profonde des grands systèmes électriques est indispensable pour relever ce défi .L’Europe, qui veut être pionnière dans cette mutation, s’est engagée dans une transition énergétique ambitieuse, qui ne sera possible qu’en développant les énergies renouvelables là où les ressources naturelles sont le plus disponibles. Ceci nécessite le déploiement de nouvelles technologies de câbles et de réseaux, pour l’éolien offshore comme pour les interconnexions. Ces projets de grande envergure, dans un contexte réglementaire et environnemental très contraignant, nécessitent une maîtrise accrue des technologies. Mais être au rendez-vous de la production renouvelable exige aussi de mieux associer les populations concernées, de trouver de nouveaux cadres de fi nancement, et de progresser encore dans l’intelligence des réseaux de transport, et dans leur coopération avec les réseaux de distribution.

Pierre BORNARDPierre BORNARD is currently the Deputy CEO of RTE, the French electricity Transmission System Operator. Pierre BORNARD has also been since 2013 the Chairman of the Board of ENTSO-E, the network of European Transmission System Operators (TSOs) for electricity established in accordance to the European legislation. He is also the Vice-President of Med-TSO, the association of the electricity TSOs from almost all the Mediterranean countries. Since the creation of Powernext SA (which created the French power and gas Exchanges) in 2001, Pierre BORNARD has been the Chairman of the Board of this company. He is also the Vice-Chairman of the Supervisory Board of EPEX Spot SE (a common subsidiary of Powernext, EEX AG and 3 European electricity TSOs – RTE, Elia and TenneT. EPEX Spot operates the spot electricity market in France, Germany, Switzerland and Austria). He is a Fellow of the IEEE (Institute of Electrical and Electronics Engineers).

Pierre MALLET Diplomed engineer from Ecole Polytechnique and Ecole Nationale Supérieure des Mines

de Paris. Three years with the Commission of the European Union (DG Energy): work on the

completion of the Internal Energy Market and on the development of cooperation with non EU countries.

Eleven years with EDF R&D: in charge of the Transmission Network Economics and Design Group during three years and of the Power System Dynamics and Control Branch during four years.

Local manager for EDF and Gaz de France during six years, in charge of power and gas distribution and meters management: responsible for power distribution to about 700.000 customers.

Presently Director for R&D and Innovation in ERDF in charge of the R&D programme of the company and of the developments of new solutions for the distribution system operation.

CIRED: member of the Directing and of the Technical Committees, chairman of Session 1 “Network Components” and of the French National Committee.

French member of the Networks Committee of Eurelectric, member of the Technology Committee of EDSO, French alternate member of the International Energy Agency WG on Smart Grids (ISGAN).

Josias Matos de Araújo Experience in Power Quality and Smart Grid, as Coordinator of Brazilian Power Quality

Working Group and Coordinator of Brazilian Smart Grid Working Group to defi ne Public Policies for Brazilian Grid,

Superintendent of Operation and Maintenance Engineering in Eletronorte, from 1995 to 2008,

Responsible of Electric Testing Laboratory in Eletronorte in 1990, Electric Energy Secretary of Ministry of Mines and Energy in Brazil, from October/2008

to August/2010, CFO of Cigré-Brazil, from 2005 to April/2011, 1st Vice President of Cigré-Brazil since April 2011, CEO of Eletronorte, from August/2010 up to June/2014, Director of Regulation Issues, since June/2014 Brazilian Coordinator of Transmission Business – BRACIER/CIER, from 1995 to 2008, Many Technical Articles published in National and International Symposium and

Conferences.

Serge Roques Owner of 53 Patents Since June 2007: Expert Emeritus in SAFRAN /LPS on Electromechanical Systems, Previous activity in AIRBUS: From Jan 2005 - March 2007: Vice President Engineering & Executive Expert in

Electrical Systems & Head of ESDY Department: All Systems Integration on all AIRBUS Programs - Future Aircraft Concept,

From 2004-2005: Aircraft Security Project Leader, From 2001 – 2003: Senior Expert in Electromechanical Systems, Aircraft Security

Project Leader (after events of Sept 11th 2001), From 1994 – 2001: Head of SY/ENAT – Energies Department, Electrical Systems,

Hydraulic, Utilities, Landing gear ,Braking System & General system architecture, From 1992 – 1993: Head of SY/CAL Department, Cockpit, Electrical Installation&

Electrical Technology & Flight test installations, From 1986 – 1991: Head of G341 Operational Group, Nose Section studies for A330/

A340, From 1982 - 1985: Head of ATR 42 Operational Group, Nose section: Cockpit & E/E

Bay, Wing, Nacelle, Electrical Installation During 1981: Head of ING Group (Integrated Nose Group), Multinational Team with MBB and BAe on the A320 program, From 1976 – 1980: Cockpit Design Engineer on A310, Cockpit & E/E Bay and Electrical installation Designer on A310 program, From 1970 – 1975: Cockpit Design Engineer A300, A300 & A300 Forward Facing

Crew Cockpit Programs

Pierre BORNARDPierre BORNARD est actuellement le Directeur général délégué de RTE, le gestionnaire français du réseau de transport d’électricité.

Pierre BORNARD est aussi depuis 2013 président du Conseil d’Administration d’ENTSO-E, l’associatibioson européenne des gestionnaires de réseaux de transport d’électricité, créée conformément à la législation européenne. Il est également Vice-président de Med-TSO, l’association des opérateurs de réseaux de transport d’électricité de la quasi-totalité des pays riverains de la Méditerranée.Depuis la création en 2001 de Powernext SA (qui a ouvert la bourse française de l’électricité et du gaz), Pierre BORNARD est également le Président du Conseil d’Administration de cette société. Il est aussi le Vice-Président du Conseil de Surveillance d’EPEX Spot SE (la fi liale 50-50 de Powernext et EEX AG qui opère le marché spot de l’électricité en France, Allemagne, Suisse et Autriche). Il est Fellow de l’IEEE (Institute of Electrical and Electronics Engineers).

Pierre MALLET Ingénieur diplômé de l’Ecole Polytechnique et de l’Ecole des Mines de Paris Trois ans à la Commission Européenne à la DG Energie: Travaux sur l’achèvement du

marché intérieur de l’énergie et sur le développement de la coopération avec les pays non européens.

Onze ans à EDF R&D: en charge pendant trois ans du groupe “Économie et conception des réseaux de transport, puis responsable de la branche “Dynamique et contrôle du réseau d’énergie” pendant quatre ans.

Gestionnaire local pour EDF et Gaz de France pendant six ans, en charge de la distribution de l’électricité et du gaz et de la gestion du comptage d’environ 700.000 clients.

Actuellement Directeur de la R & D et de l’innovation à ERDF en charge du programme R&D de la société et du développement de nouvelles solutions pour le fonctionnement du réseau de distribution.

CIRED: membre du Comité Directeur et du Comité Technique, président de la session 1 «Composants de réseaux» et du Comité National Français.

Membre français du Comité Réseaux d’Eurelectric, membre du Comité de la technologie d’EDSO, membre français suppléant de l’Agence internationale de l’énergie, GT sur les Smart Grids (ISGAN).

Josias Matos de Araújo Expérience dans le domaine de la qualité de l’énergie et des Smart Grids, en tant que

coordinateur du Groupe de travail Brésilien “Qualité de l’Energie” et coordinateur du Groupe de travail Brésilien “Smart Grids” pour défi nir la politique publique Brésilienne du réseau,

Directeur de l’ingénierie exploitation et maintenance d’Eletronorte, de 1995 à 2008, Responsable du laboratoire d’essais électriques d’Eletronorte en 1990, Secrétaire de l’Energie Electrique au Ministère des Mines et de l’Energie du Brésil

d’Octobre 2008 à Août 2010. CFO du CNB Cigré-Brazil de 2005 à Avril 2011, 1st Vice Président du CNB Cigré-Brazil depuis Avril 2011, Président d’Eletronorte, de juin 2010 à Août 2014, Directeur de la régulation depuis Juin 2014, Coordinateur Brésilien des activités de transport d’énergie, BRACIER/CIER, de 1995

à 2008, Nombreuses communications techniques publiées à des symposiums et conférences

internationales.

Serge Roques37 ans d’activités Engineering chez AIRBUS sur 8 programmes avion : A300, A310, A320, A330/340, ATR, A380, A400M, A350, pour:

La conception des cockpits de tous les avions cités précédemment, La conception des systèmes d’énergie non propulsive comme Chef du Département

Electrique avec :Génération, Distribution, installation et Technologie électrique pendant plus de 25 ans et Hydraulique avec les mêmes thèmes que pour électricité Génération, Distribution, installation et Technologie pendant 8 ans.

La défi nition des systèmes de SURETE à bord (porte cockpit blindée, caméras de surveillance à bord, liaison ATC directe, etc … ) suite aux événements du 11 Septembre 2001.

L’installation avec une équipe multinationale (Brème, Hambourg, Filton, Getafe et Toulouse ) de tous les systèmes de bord en plus de l’électricité et l’hydraulique.

Il a terminé sa carrière chez AIRBUS avec le titre de Vice Président Engineering, Executive Expert en Systèmes Electromécaniques.Il est possesseur de 53 Brevets « tous systèmes » auxquels il a toujours associé au moins un à deux techniciens ou ingénieurs de son Département.

TECHNICAL EXHIBITION JICABLE’15

PARIS VERSAILLES 22 24 JUNE 2015

Company BoothNumber Level Country

ABB 35 Le Nôtre – Level 2ALROC 45 Le Nôtre – Level 2AP Sensing GmbH 05 Mazarin – Level 0 GermanyARTOFIL 37 Le Nôtre – Level 2 The Netherlandsb2 electronic GmbH 02 Mazarin – Level 0 AustriaBAUR GmbH 34 Mazarin – Level 0 AustriaBRUGG CABLES 14 Mazarin – Level 0 SwitzerlandCYME International T&D Inc. 39 Le Nôtre – Level 2 CanadaDNV GL / KEMA 35bis Le Nôtre – Level 2 The NetherlandsDubai Cable Company – Ducab 29 Lobby – Level 0 United Arab EmiratesEDF R&D – EDF CIST 12 Mazarin – Level 0 FranceEMELEC Elektrik Müh. San. Tic. A.S. 38 Le Nôtre – Level 2 TurkeyEvergreen High Voltage 36 Le Nôtre – Level 2 USAGENERAL CABLE 30 Mazarin – Level 0 H&R Group (The) 42 Le Nôtre – Level 2 United KingdomHAEFELY HIPOTRONICS 22 Mazarin – Level 0HIGH VOLTAGE TEST SYSTEMS HVTS 23 Mazarin – Level 0 FranceHIGH VOLTAGE, INC 40 Le Nôtre – Level 2 USAHIGHVOLT Pruftechnik Dresden GmbH 03 Lobby – Level 0 GermanyHVPD 17 Mazarin – Level 0 IMERYS Graphite & Carbon 18 Mazarin – Level 0 SwitzerlandKINECTRICS 41 Le Nôtre – Level 2 LIOS Technology GmbH 28 Mazarin – Level 0 GermanyMohaupt High Voltage GmbH 04 Mazarin – Level 0 AustriaNEXANS 32 Mazarin – Level 0 FranceNKT CABLES GmbH & Co 26 Mazarin – Level 0 GermanyNovinium / UtilX Europe GmbH 31 Lobby – Level 0 GermanyOMICRON electronics GmbH 01 Lobby – Level 0 AustriaOMNISENS 09 Mazarin – Level 0 ONSITE HV 24 Mazarin – Level 0 PFISTERER SAS 21 Mazarin – Level 0 FrancePhenix Technologies, Inc. 07 Mazarin – Level 0 USAPOURTIER 15 Mazarin – Level 0 Power Diagnostix Systems GmbH 43 Le Nôtre – Level 2 GermanyPRYSMIAN GROUP 06 Mazarin – Level 0 RTE 16 Mazarin – Level 0 FranceSCAPA GROUP PLC 44 Le Nôtre – Level 2 Seba KMT Groupe MEGGER 20 Mazarin – Level 0SENSORNET 27 Lobby – Level 0 SICAME Group 10 Mazarin – Level 0 FranceSMEETS S.A. 19 Mazarin – Level 0 BelgiqueSTRI 25 Mazarin – Level 0 SwedenWIRESCAN 11 Mazarin – Level 0

ABB AB High Voltage Cables

ABB AB High Voltage CablesVerkövägen 94SE-371 23 KarlskronaSweden

Tel: +46 455 556 00Fax: Email: [email protected]: www.abb.com/cablesContact: ABB Reception, Karlskrona

Booth number/Stand 35 (Le Nôtre – Level 2)

ABB is a world-leading supplier of high-voltage cable systems and installation services for all types of submarine and underground power transmission applications. With experience dating back to 1883, ABB has an unrivaled track record of delivering high voltage AC and DC cable system solutions. ABB is operating two manufacturing units for high voltage cables, one in Karlskrona, Sweden and one in Huntersville NC, United States. High voltage cable links are essential components of future sustainable energy systems that will need to transmit vast amounts of electricity over long distances, often across or between countries.

ABB is a leader in power and automation technologies that enable utility, industry, and transport and infrastructure customers to improve their performance while lowering environmental impact. The ABB Group of companies operates in roughly 100 countries and employs about 140,000 people.

ABB est un fournisseur de rang mondial de systèmes de câbles à haute tension prenant en charge la défi nition, la fabrication et l’installation pour tous types de câbles sous-marins et enterrés. Avec une expérience dont l’origine remonte à 1883, ABB a un palmarès inégalé quant à fournir des solutions de systèmes de câbles à haute tension AC et DC. ABB opère deux unités de fabrication de câbles à haute tension, l’une à Karlskrona, en Suède et l’autre à Huntersville NC, aux États-Unis. Les liaisons par câbles à haute tension sont des composants essentiels des futurs systèmes d’énergie durable qui devront transmettre de grandes quantités d’électricité sur de longues distances, et cela le plus souvent à travers ou entre les pays.ABB est un leader mondial dans les technologies de l’énergie et de l’automation qui permet à ses clients dans l’industrie, le transport, les infrastructures et les utilités d’améliorer leurs performances tout en diminuant l’impact de leurs activités sur l’environnement. Le Groupe ABB est présent dans environ 100 pays et emploie quelque 140000 personnes.

ALROC

ALROCZ.I. de la Fonderie72160 TUFFEFrance

Tel: +33 2 43 71 11 80Fax: +33 2 43 71 16 51Email: [email protected]: www.alroc.frContact: Stephane VALLI

Booth number/Stand 45 (Le Nôtre – Level 2)

ALROC company conceives and manufactures for more than 25 years stripping pliers tools and machines for electric cables preparation Low Voltage (LV), Medium Voltage (MV), High Voltage (HV), for de-energised works and live works (insulated tools TST EN60900). ALROC company also designs special tools, keys and cable fi xing clamps.

Its engineering and design department produces tools adapted to the specifi c needs of its customers according to their schedule of conditions.

La société ALROC conçoit et fabrique depuis plus de 25 ans des pinces, des outils et des machines de dénudage pour la préparation des câbles électriques basse tension (BT), moyenne tension (HTA), haute tension (HTB), pour travaux hors et sous tension (outillage isolé TST EN60900). Elle conçoit également des outils spéciaux, des clefs et des colliers de maintien des câbles.

Son bureau d’études réalise des outils adaptés aux besoins spécifi ques de ses clients sur cahier des charges.

ARTOFIL

ARTOFILIndustrieweg 215753PB - DeurneThe Netherlands

Tel: +31 493329884Fax: +31 493310385Email: michelvanvelzen@artofi l.nlWebsite: www.artofi l.comContact: Michel van Velzen

Booth number/Stand 37 (Le Nôtre – Level 2)

Since 1951, ARTOFIL is the genuine manufacturer of high performance yarns, where our expertise has contributed to become the leading manufacturer of waterblocking yarns to the cable industry. With a dedicated team of experts, ARTOFIL have proven to be a full collocutor in the cable sector.

Over the years, ARTOFIL has developed a complete range of waterblocking fi ne-, fi ller- and binder yarns to be able to offer the cable manufacturers a solution to produce a cost- effective waterblocked cable design, even in a saline environment.

Our latest product developments enlarged our position in the market and put us at the forefront of waterblocking solutions. With our complete range of products we are ready for the waterblocking needs of today and tomorrow in all cable designs including subsea applications.

We are pleased to welcome you to visit our stand to share ideas to create new waterblocking cable designs in the most cost-effective way.

ARTOFIL: “ FIRST CHOICE IN COST-EFFECTIVE WATERBLOCKING CABLES SOLUTIONS.”

Depuis 1951, ARTOFIL est fabricant de fi ls haute performance. Cette expertise a permis a ARTOFIL de devenir le premier fabricant de fi lins d’étanchéité pour l’industrie du câble. Avec son équipe d’experts, ARTOFIL démontre être un interlocuteur effi cace pour l’industrie du câble.

Fruit d’une longue expérience ARTOFIL a développé une gamme complète de fi ls, fi lins et torons d’étanchéité, pour offrir aux fabricants de câbles une solution à la conception des câbles à étanchéité longitudinale y compris en environnement salin.

Nos derniers développements de produits ont élargie notre position dans ce secteur à la pointe de ce marché. Avec notre gamme complète de produits, nous pouvons répondre aux besoins d’aujourd’hui et de demain dans le secteur des fi lins d’ètanchéité pour tous les modèles de câbles, y compris en applications sous-marines.

C’est avec plaisir que nous vous accueillons sur notre stand “Artofi l” pour partager vos et nos expériences et idées dans le domaine du blocage d’étanchéité au meilleur coût.

ARTOFIL: “PREMIER CHOIX DE FILINS D’ÉTANCHEITÉ FIABLES ET ÉCONOMIQUES POUR L’INDUSTRIE DU CÂBLE.”

AP Sensing GmbH

AP Sensing GmbHHerrenberger Straße 13071034 - BoeblingenGermany

Tel: +49 7031 309 66 15Fax: +49 7031 309 66 11Email: [email protected]: www.apsensing.comContact: Jeff LEE

Booth number/Stand 05 (Mazarin – Level 0)

AP Sensing is a leading provider of DTS (Distributed Temperature Sensing) solutions for electrical transmission networks. Optical fi ber monitors high-voltage power cables, detecting hot spots and condition assessment. Real-time temperature data determines the maximum possible load for the cables (RTTR - Real Time Thermal Rating). Our sophisticated SmartVision management software suite gives operators a clear overview of the thermal status of your circuits, for optimal network planning insight. With AP Sensing’s power management solution you get maximum network performance at safe ampacity levels.

www.apsensing.com

AP Sensing est un fournisseur leader dans le domaine de la technologie DTS (Distributed Temperature Sensing, Capteurs de Température Distribués) pour les réseaux de transport d’électricité. La fi bre optique surveille les câbles électriques à haute tension et détecte les points chauds. Les données de température en temps réel contrôlent la charge maximale possible pour les câbles (RTTR - Real Time Thermal Rating, Surveillance Thermique en Temps Réel). Notre logiciel de gestion SmartVision offre aux opérateurs un aperçu clair de l’état thermique de vos circuits pour une planifi cation optimale de vos réseaux. Avec la solution de gestion énergétique d’AP Sensing vous obtenez une performance maximale du réseau à des niveaux d’intensités maximales sécuritaires.

www.apsensing.com

b2 electronic GmbH

b2 electronic GmbHRiedstrasse 16833 - KlausAustria

Tel: +43 5523 57373Fax: +43 5523 57373-5Email: [email protected]: www.b2hv.atContact : Jürgen Jakober

Booth number/Stand 02 (Mazarin – Level 0)

b2 electronic GmbH is an Austrian-based manufacturer of high-voltage test equipment for cable testing, cable diagnostics and dielectric oil testing.

HVA series - VLF (0.1 Hz) test set - b2 electronic offers a comprehensive range of VLF (0.1 Hz) test sets (HVA series) from 28 kV up to 200 kV of remarkably small dimensions and weight. Our VLF test sets are dry-type test systems, which would otherwise require routine maintenance and limit operational time.

Tan Delta (TD) diagnostic system – The tan delta measuring instruments are available as external devices or as an integrated function in a HVA high voltage generator.

Partial Discharge (PD) diagnostic system – A new range of extremely easy-to-use Partial discharge Devices complements the cable diagnostics portfolio.

Dielectric Oil test sets - Devices with a very fast switch-off time after fl ash over enables b2 Oil Test Sets to measure also modern silicon, mineral and ester oils without damaging the test sample.

Basée en Autriche, la société b2 electronic GmbH est un fabricant de matériel de test Haute Tension pour le

Série HVA – Systèmes de test VLF (0,1 Hz) – b2 electronic propose une gamme complète d’ensembles de test VLF (0,1 Hz, série HVA), de 28 kV jusqu’à 200 kV, particulièrement compacts et légers. Nos ensembles VLF sont basés sur une technologie dite « sèche », qui évite la maintenance régulière et les limites en temps de fonctionnement opérationnel dus à l’huile.

Système de diagnostic Tangente Delta (TD) – les instruments de mesure de Tangente Delta sont, soit disponibles sous forme d’accessoires externes, soit directement intégrés dans un générateur HVA Haute Tension.

Système de diagnostic à Décharges Partielles (DP) – Une nouvelle série d’appareils de mesure de Décharges Partielles extrêmement simples à utiliser complète la gamme de diagnostic de câbles.

Ensembles de test diélectriques d’huile – nos systèmes testeurs d’huile b2, avec leur temps d’extinction rapide après déclenchement d’un arc, autorisent également les mesures sur les huiles récentes minérales, silicones ou à base d’esters, sans endommager l’échantillon de test.

BAUR GmbH

BAUR GmbHRaiffeisenstraße 86832 - SulzAustria

Tel: +43 5522 4941 0Fax: +43 5522 4941 3Email: headoffi [email protected] : www.baus.euContact: Christina PLANK

Booth number/Stand 34 (Mazarin – Level 0)

BAUR GmbH is market leader of testing and measurement technology that prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems

BAUR product porfolio:• Cable fault location• Cable testing & diagnostics• Insulating fl uids testing• Cable test vans & systems

La technologie de contrôle et de mesure de BAUR GmbH empêche l’apparition de dommages dans les réseaux et les installations, permet de planifi er précisément les investissements pour l’entretien et localise précisément et le plus rapidement possible les défauts. Pour la fi abilité de vos réseaux et de vos installations.

Gamme de produits :• Localisation des défauts de cable• Essai et diagnostic de câble• Essai d’huile diélectrique• Laboratoires mobiles et systèmes

BRUGG CABLES

Brugg Kabel AG / Brugg CablesKlosterzelgstrasse 285201 - BruggSwitzerland

Tel: +41 (0) 56 460 35 25Fax: +41 (0) 56 460 35 36Email: Website: www.bruggcables.comContact: [email protected]

Booth number/Stand 14 (Mazarin – Level 0)

Brugg Cables offers a complete portfolio of products for power supply and data transmission, from system business with high-voltage cables with corresponding couplers and sealing ends to medium and low-voltage cables and fi ttings as well as fi ber-optic cables. At the same time, Brugg Cables is one of the few cable manufacturers worldwide capable of producing cable systems and accessories for the present highest voltage level of 500 kilovolts. The company cooperates closely with customers to implement turnkey projects such as cabling of power supply systems. With its Industry business unit, Brugg Cables is one of the most important suppliers of customized cable solutions for industrial applications in Europe. Brugg Cables deploys its entire technical expertise and experience and partners projects through all stages of development, design, purchasing, production, testing and logistics according to the customer’s specifi c requirements, right up to installation on site.

Des activités système avec des câbles à haute tension dotés de manchons de raccordement et de terminaisons correspondants jusqu’aux câbles à fi bres optiques en passant par les câbles et garnitures pour basse et moyenne tension, Brugg Cables proposer une gamme complète de produits destinés à l’approvisionnement énergétique et à la transmission de données. Dans ce contexte, Brugg Cables est l’un des rares fabricants de câbles au monde à réussir à fabriquer des systèmes de câbles et des accessoires pour le niveau de tension de 500 kilovolt, le plus élevé qui existe à l’heure actuelle. En étroite collaboration avec le client, Brugg Cables réalise des projets clés en mains, tels que le câblage de stations d’approvisionnement en électricité. Avec son unité opérationnelle Industry, Brugg Cables fait partie des principaux prestataires européens de solutions de câbles pour applications industrielles répondant aux attentes précises des clients. Brugg Cables déploie toutes ses connaissances techniques et toute son expérience dans l’accompagnement de projets depuis le développement jusqu’au montage sur place en passant par la conception, les achats, la production et la logistique, selon les exigences spécifi ques du client.

CYME International T&D Inc.

CYME International T&D Inc.1498 rue Roberval, Suite 104J3V 3P8 -St-Bruno-de-Montarville, QuébecCanada

Tel: 450-461-3655Fax: 450-461-0966Email: [email protected]: WWW.CYME.COMContact: Kamara WOULEYE

Booth number/Stand 39 (Le Nôtre – Level 2)

CYME International (now part of Eaton’s Cooper Power Systems) provides Power Engineering Software & Solutions for transmission, distribution and industrial power systems; featuring advanced applications for power system modeling and simulation of electrical grids of any type and a wide range of specialized engineering services related to system planning.

Our solutions stand behind thousands of T&D projects in over 100 countries around the world.

Visit us at booth 39 for a demonstration of CYMCAP, CYME cable ampacity rating program dedicated to modeling the thermal behavior of power cables installation and CYMDIST one of the most advanced analysis software package for distribution network planning.

CYME International (faisant partie d’Eaton’s Cooper Power Systems) propose logiciels et solutions d’analyse de réseaux d’énergie électrique de transport, de distribution et industriels incluant des applications avancées de modélisation et de simulation de réseaux de tous types; ainsi qu’une large gamme de services d’ingénierie reliés à la planifi cation.

Nos solutions sont au cœur de milliers de projets en T&D dans plus de 100 pays.

Venez nous rencontrer au kiosque 39 pour une démonstration de CYMCAP, le logiciel de calcul du courant maximal admissible des câbles de CYME dédié à la modélisation du comportement thermique des câbles de puissance et de CYMDIST, l’un des logiciels de planifi cation des réseaux de distribution les plus avancés.

DNV GL - Energy

DNV GL - EnergyUtrechtseweg 310 6812 AR - ArnhemNetherlands

Tel: + 31 26 356 9111Email: [email protected]: www.dnvgl.com/energyContact: Diederik Houtman

Booth number/Stand 35 bis (Le Nôtre – Level 2)

In DNV GL we unite the strengths of DNV, KEMA, Garrad Hassan, and GL Renewables Certifi cation. DNV GL’s 2,500 energy experts support customers around the globe in delivering a safe, reliable, effi cient, and sustainable energy supply. We deliver world-renowned testing, certifi cation and advisory services to the energy value chain including renewables and energy effi ciency. Our expertise spans onshore and offshore wind power, solar, conventional generation, transmission and distribu¬tion, smart grids, and sustainable energy use, as well as energy markets and regulations. Our testing, certifi cation and advisory services are delivered independent from each other.

At JICABLE 2015 DNV GL presents a new feature of Smart Cable Guard: the Breakdown Locator. Smart Cable Guard is a highly effi cient multifunctional online monitoring system for MV-cables that has proven to reduce the SAIDI and SAIFI fi gures considerable. Added with the Breakdown Locator even hidden faults in an isolated neutral network can be detect and located with a pinpointing accuracy of 1 % of the cable length. To learn more about this unique system and understand how it can.

DNV GL regroupe DNV KEMA, Garrad Hassan, et GL Renewables certifi cation. 2.500 experts en énergie de DNV GL aide ses clients du monde entier pour délivrer un approvisionnement énergétique sûr, fi able, effi cace et durable. Nous réalisons des tests de renommée mondiale, la certifi cation et du conseil à l’ensemble de la chaîne de valeur de l’énergie, y compris dans les domaines des énergies renouvelables et de l’effi cacité énergétique. Notre expertise couvre l’onshore, l’offshore, l’énergie éolienne, l’énergie solaire, la production conventionnelle, la transmission et la distribution, les réseaux intelligents et l’utilisation durable de l’énergie, ainsi que les marchés de l’énergie et de la réglementation. Nos services d’essais, de certifi cation et de conseil sont séparés et indépendants.

A JICABLE 2015 DNV GL présente une nouvelle fonctionnalité Smart Cable Guard: le localisateur de défauts. Intelligent Cable Guard est un système de surveillance multifonctionnel en ligne très effi cace pour câbles MT qui a démontré sa capacité à réduire considérablement les SAIDI (System Average Interruption Duration Index) et SAIFI (System Average Interruption Frequency Index ). Avec avec le localisateur de défauts, même les défauts cachés dans un réseau à neutre isolé peuvent être détectés et situés avec une précision de 1% de la longueur du câble. Pour en savoir plus sur ce système unique et de comprendre comment il peut.

Dubai Cable Company – Ducab

Dubai Cable Company – DucabDubai, Jebel Ali, P.O Box 1152900971 - DubaiUnited Arab Emirates

Tel: +971 4 815 8888Fax: +971 4 815 8111Email: [email protected]: www.ducab.comContact: Maryam Alfalasi

Booth number/Stand 29 (Lobby – Level 0)

Ducab is a leading provider of high-quality cabling products in the Middle East, with its own manufacturing facilities for cables, a copper rod mill, a PVC plant, and an aluminium plant. It also acquired its fi rst overseas plant, AEI Cables UK, earlier in 2014. Ducab has power cables that are certifi ed for nuclear and solar use, and also offers a range of lead-sheathed, fi re retardant, and rubber cables, apart from cable components and accessories. The company is jointly owned by the Governments of Abu Dhabi and Dubai, and Ducab customers are spread across multiple geographies and industry sectors. Ducab has received multiple citations from certifying authorities as well as industry bodies.

Ducab has supplied electrical cables to a number of landmark projects in the UAE, including the Burj Khalifa, Dubai Metro, Emirates Palace, Burj Al Arab, Atlantis the Palm and Yas Marina Circuit. With record sales of AED 5.1 billion for 2013, Ducab is a regional leader in the design, development, manufacture and marketing of copper and aluminum cable products for the defence, energy, industrial, construction, rail, specialty and nuclear energy sectors.

Ducab est un leader sur le marché des câbles de haute qualité au Moyen-Orient, avec ses propres usines de câbles, de cuivre machine, de PVC, et d’aluminium. En 2014, la société a également acquis sa première usine à l’étranger, AEI Cables, en Angleterre. Ducab propose des câbles d’alimentation homologués destinés à des utilisations nucléaire et solaire, ainsi qu’une large gamme de câbles gainés plomb, ignifugés et en isolation caoutchouc, en plus des composants et des accessoires de câble. La société est détenue conjointement par les gouvernements d’Abu Dhabi et de Dubaï. Les clients de Ducab sont répartis sur une large zone géographique et s’étendent à différents secteurs de l’industrie. Ducab a reçu de nombreuses citations d’autorités de certifi cation et d’organisations de son secteur.

Ducab a fourni des câbles électriques pour des projets d’envergure aux Emirats Arabes Unis, tels que la tour Burj Khalifa, le métro de Dubaï, l’Emirates Palace, les hôtels Burj Al Arab et Atlantis The Palm ainsi que le circuit de Formule 1 Yas Marina Circuit. Avec des ventes record de 1,7 milliard d’euros en 2013, Ducab est un leader régional dans la conception, le développement, la fabrication et la commercialisation de câbles en cuivre et en aluminium destinés aux secteurs de la défense, de l’énergie, de l’industrie, de la construction, du transport ferroviaire, de l’énergie nucléaire ainsi qu’ à différents secteurs spécialisés.

EDF, EDF R&D, EDF CIST

EDF22 - 30 avenue de Wagram75382 -Paris Cedex 08France

EDF R&DTel: +33 1 60 73 70 77Email: sebas [email protected]: networks-lab.edf.comContact: Sébas en CORNET

EDF CISTTel: +33 1 43 69 81 57Email: cist-consul [email protected]: engineeringtransmission.edf.comContact: Marc SAINT-FAUST

Booth number/Stand 12 (Mazarin – Level 0)

The EDF Group is the world’s largest power company, active in all activities from transmission to distribution. EDF operates in over 40 countries worldwide. It is the leading nuclear operator in the world, the leading hydropower producer in Europe and the leading electricity supplier in France

EDF owns large electrical testing laboratories dedicated to do cables and accessories research and development. A devoted team of 75 experts, engineers and technicians operates this full range of testing facilities. Particularly suitable for qualifi cation tests, these laboratories are totally open to external customers. They work independently and under the ISO 17025 accreditation. The fl exibility of our testing facilities and our teams with 50 years of experience also enable us to support manufacturers in their development and investigative tests.

In addition, the EDF power system & transmission engineering centre (CIST) focuses on all disciplines relating to power transmission (power systems and transmission grids). With its teams of multidisciplinary experts, it provides technical support to grid operators. CIST is frequently in charge of solving complex technical issues associated with the development, operation and maintenance of electricity networks.

Le groupe EDF est le plus important énergéticien au monde, présent dans tous les secteurs, du transport jusqu’à à la distribution. EDF intervient dans plus de 40 pays. Il est le premier opérateur nucléaire dans le monde, le premier producteur hydraulique en Europe et le premier fournisseur d’électricité en France.

Dans le domaine de la R&D, EDF dispose de grands laboratoires d’essais électriques pour les câbles et leurs accessoires aux Renardières. Une équipe dédiée de 75 experts, ingénieurs, techniciens met en œuvre cet ensemble complet de moyens d’essais. Particulièrement adaptés aux essais de qualifi cation, ces laboratoires sont complètement ouverts aux clients externes à EDF pour travailler en toute indépendance et sous accréditation ISO 17025. La fl exibilité de nos moyens d’essais et les 50 années d’expérience de nos équipes nous permettent d’accompagner les fabricants dans leurs essais de développement et d’investigation.

EDF dispose aussi d’un Centre d’Ingénierie sur les Systèmes de Transport (CIST) spécialisé dans l’ensemble des activités se rapportant au transport électrique (réseaux électriques et réseaux de transport). Avec ses équipes pluridisciplinaires, il fournit un appui technique aux opérateurs de réseaux. Le CIST résout régulièrement des problèmes techniques complexes liés au développement, à l’exploitation et à la maintenance des réseaux électriques.

EMELEC Elektrik Müh. San. Tic. A.S.

EMELEC Elektrik Müh. San. Tic. A.S.Eski Ankara Yolu İ.T.O.S.B 4.Cad. No:25 Tepeören Tuzla İstanbul/Turkey34959 - IstanbulTurkey

Tel: +90 216 593 37 15Fax: +90 216 593 37 21Email: [email protected]: www.emelec.com.trContact: Kemal Gursoy

Booth number/Stand 38 (Le Nôtre – Level 2)

GENERAL ACTIVITYEMELEC, as an engineering and contracting company is actively engaged in two main areas;• Production; Link Boxes of all types and design being the MAIN LINE of Production. Also included are Cable cleats, and special cable tools used in fi eld

applications.• High Voltage XLPE Power Cable Systems Project engineering; Project executions both national and overseas.

PRODUCTS, SYSTEMS AND SERVICESLink box: is electrically and mechanically one of the integral accessories of HV underground cable Bonding System, associated with HV XLPE power cable system up to 500 kV• Cross Bonding Link Box for joint locations• Direct Earthing Link Box for Terminations• Earthing with SVL type Link box for Terminations.

Cable Cleat: Trefoil and single cable applications where moderate to levels upto 40 kA-1 sec/50 kA-1 sec/63 kA-1 sec short circuit withstand are required.

ACTIVITÉ GÉNÉRALEEMELEC, en tant qu’une société d’ingénierie et de contracting, s’engage activement dans deux domaines principaux:• La Production : la conception et la fabrication de tous types de Boîtes de Liaison qui forment la ligne principale de production. Les taquets de câbles

et les outils spéciaux utilisés dans les applications sur le terrain sont également inclus dans la gamme de production.• Ingénierie de projets pour des systèmes de câbles haute tension au polyéthylène réticulé (XLPE) : exécutions des projets nationaux et dans le monde

entier.

PRODUITS, SYSTÈMES ET SERVICESLa Boîte de Liaison : électriquement et mécaniquement l’un des accessoires intégrantes de système de câble souterrain, associé à des systèmes de câbles d’alimentation HT au PR jusqu’à 500 kV.• Boîte de liaison pour des jonction de transition (en version cross-bonding)• Boîte de liaison pour les extrémités (terminaisons) : de type « mise à la terre directe »• Boîte de liaison pour les extrémités (terminaisons) : de type « mise à la terre avec limiteurs de tension de la gaine »

Taquet Câble : coinceur pour les applications de pose en trèfl e et simple des câbles où des niveaux modérés de tenue à des courts circuits jusqu’à 40 kA-1 sec / 50 kA-1 sec / 63 kA-1 sec sont obligatoires.

Evergreen High Voltage

Evergreen High VoltageP.O. Box 9Lake Placid, NY 12946USA

Tel: +1 518 480 8226Fax: +1 518 523 5973Email: [email protected]: www.evergreenhighvoltage.comContact: Bill Larzelere

Booth number/Stand 36 (Le Nôtre – Level 2)

Evergreen High Voltage, LLC is dedicated to innovation within a mature industry to provide premium quality high voltage testing equipment at a lower cost through strategic partnerships with top suppliers who can implement our designs with consistency.

All of our designs are done in the USA. Drawing on years of experience, our goal is to be the world leader for the supply of high voltage AC, DC and Impulse Test and Measurement Systems.

MANQUE FRANCAIS

Evergreen High Voltage, LLC se consacre à l’innovation dans une industrie mature pour fournir l’équipement d’essai haute tension de qualité supérieure à moindre coût grâce à des partenariats stratégiques avec les meilleurs fournisseurs qui savent mettre en œuvre nos conceptions avec cohérence.

La conception de nos équipement est intégralement développée aux Etats-Unis . Avec des années d’ expérience, notre objectif est d’être le leader mondial pour la fourniture d’équipements de test et de mesure haute tension AC, DC et Impulsion.

GENERAL CABLE

GENERAL CABLErue de Varennes Prolongée77130 - Montereau-Fault-YonneFrance

Tel: +33 (0)1 60 57 30 00Website: www.generalcable-fr.comContact: Marie-Thérèse BLANOT

Booth number/Stand 30 (Mazarin – Level 0)

General Cable has been a wire and cable innovator for over 170 years, always dedicated to connecting and powering people’s lives. With more than 13,000 employees and $6 billion in revenues, we are one of the largest wire and cable manufacturers in the world.

Our company serves customers through a global network of 38 manufacturing facilities in our core operating regions and has worldwide sales representation and distribution. We are dedicated to the production of high-quality aluminum, copper and fi ber optic wire and cable and systems solutions for the energy, construction, industrial, specialty and communications sectors. With a vast portfolio of products to meet thousands of diverse application requirements, we continue to invest in research and development in order to maintain and extend our technology leadership by developing new materials, designing new products, and creating new solutions to meet tomorrow’s market challenges.

General Cable offers our customers all the strengths and value of a large company, but our people give us the agility and responsiveness of a small one. We service you globally or locally.

Visit our Website at www.generalcable.com

Depuis 170 ans, General Cable est un pionnier dans la fabrication de câbles et fi ls, avec pour objectif constant de connecter et d’éclairer la vie des gens. Aujourd’hui, avec plus de 13000 employés et 5 milliards d’euros de chiffres d’affaires, nous sommes l’un des plus grands fabricants de câbles et fi ls au monde.

Notre entreprise sert ses clients à travers un réseau global de 38 sites de production et possède des représentants commerciaux et des points de distribution dans le monde entier. Nous nous consacrons à la production de fi ls et câbles de haute qualité en aluminium, cuivre et à fi bres optiques ainsi que de systèmes pour les secteurs de la construction, de l’industrie, spéciaux et des télécommunications. Avec une large gamme de produits pour satisfaire les besoins de milliers d’applications, nous continuons à investir en recherche et développement dans le but de maintenir et d’étendre notre leadership technologique en développant de nouveaux matériaux, en dessinant de nouveaux produits, et en créant de nouvelles solutions pour pouvoir répondre aux challenges de demain.

General Cable offre à nos clients toutes les forces et valeurs d’une grande entreprise, mais nos hommes nous donnent la fl exibilité et la réactivité d’une petite entreprise. Nous sommes à votre service mondialement ou localement.

Visitez notre site Internet : www.generalcable-fr.com

H&R Group (The)

H&R Group (The)Dudley RoadDY4 8EH - Tipton, West MidlandsUnited Kingdom

Tel: +44 (0) 121 522 0100Fax: +44 (0) 121 522 0115Email: [email protected]: www.hur.comContact: Gravin Morland

Booth number/Stand 42 (Le Nôtre – Level 2)

When cable manufacturers demand reliability they choose The H&R Group for their cable fl uid and compound technology.

Our business supplies both water blocking technology and dielectric compounds for the telecommunication, fi bre optic and medium-to-high-voltage power sectors. This portfolio includes• Dielectric fl uids for high voltage AC paper insulated cables.• Impregnating compounds for MV AC paper insulated cables.• Bitumen based Flooding Compounds for bonding and corrosion protection.• Super absorbent polymers for water blocking applications.• Conductor Sealing Products for XLPE cables…

Additionally, The H&R Group also manufacture plasticisers and waxes blended to meet specifi c cabling applications.

Investment by the business has lead to the development of water blocking products for ROV and Umbilical cables, including a range of hydrogen absorbing gels.

For further information on The H&R Group cable compound technology visit http://hur.com/en/products/cable-fi lling-compounds.html

VERSION FRANCAISE A RELIRE PAR M. DESCHAMPS

Lorsque les fabricants de câbles exigent la fi abilité, ils choisissent Le groupe H & R pour leurs composés isolants ou d’étanchéité.

Nos fournitures comprennent les produits d’étanchéité et les composés diélectriques pour la télécommunication, la fi bre optique et les câbles d’énergie de la moyenne à la haute tension. Ce portefeuille comprend• Fluides diélectriques pour câbles haute tension AC isolés au papier imprégné.• Composés d’imprégnation pour papier et câbles isolés MV AC.• Composés de bitume pour le collage et la protection contre la corrosion.• Polymères super absorbants pour les applications en blocage d’étanchéité.• les produits d’étanchéité pour conducteurs de câbles XLPE ...

En outre, le groupe H & R fabrique des plastifi ants et des cires pour répondre à des applications particulières.

L’implication de l’entreprise dans ces domaines a conduit au développement de produits d’étanchéité pour câbles ombilicaux et ROV, y compris une gamme de gels absorbeurs d’hydrogène.

Pour plus d’informations sur nos technologies de composés pour câble, visiter notre site H & R Group h p://hur.com/en/products/cable-fi lling-compounds.html

HAEFELY HIPOTRONICS

HAEFELY HIPOTRONICSBirsstrasse 3004052 - BaselSwitzerland

Tel: + 41 61 373 4111Fax:+ 41 61 373 4912Email: [email protected]: www.haefely-hipotronics.comContact: Pascal Lequitte

Booth number/Stand 22 (Mazarin – Level 0)

Haefely Hipotronics is a market leader in the fi eld of high voltage test equipment for the transformer and cable industry.

The Company offers a wide range of instruments and complete high-voltage test laboratories for measurements and diagnostics in laboratories, factories and in the fi eld.

As a leading supplier in the high voltage test equipment business, Haefely Hipotronics has a reputation for quality and reliability based on an extensive product range and vast experience. The innovative use of highly sophisticated equipment, fi rst class quality and long experience in test applications are the guarantee of accuracy, effi ciency and reliability of various test methods.

Customer-support is guaranteed by a vast worldwide network of well trained and an experienced crew of Service engineers.

The Company is part of Hubbell Inc., USA.

HIGH VOLTAGE, INC.

HIGH VOLTAGE, INC.31 County Rt 7ACopake, New YorkNY 12516USA

Tel: +1 518 329 3275Fax: +1 518 329 3271Email: [email protected]: www.hvinc.comContact: Tom Grayson / Ed Kirby

Booth number/Stand 40 (Le Nôtre – Level 2)

High Voltage, Inc. of Copake, NY produces quality products including: high voltage withstand, diagnostic, and fault-locating test equipment for shielded power cables, hipots for testing substation equipment and industrial OEM production testing applications. Products offered are: VLF ( Very Low Frequency ) AC Hipots from 30 kV to 200 kV VLFAC with variable test frequencies of 0.1 Hz to 0.01 Hz. VLF models are available with load ratings from 0.4 μƒ to 50μƒ; VLF Tan delta bridges and VLF Partial Discharge measuring instruments for power cable diagnostics and cable life trending; Concentric neutral integrity test sets, DC Hipot/Insulation testers, available from 37.5 kV to 600 kV DC, AC Dielectric test sets from 3 kV to 300 kV AC, with power ratings of up to 40 KVA; Portable AC Hipots with shielded output cable up to 50 kV AC @ 3 kVA; Liquid dielectric test sets up to 100 kV AC for testing to ASTM and IEC standards; Aerial lift testers from 120 kV AC to 300 kV AC; Cable fault locators / Surge generators with controlled energy outputs up to 36 kV; TDR/Radar and acoustic fault locating devices. High Voltage also manufactures various custom designed motor and generator test instruments. We are easy to reach ([email protected]) and happy to help you with your application or a quote. Please visit our website at www.hvinc.com and let us know how we can help you.

High Voltage, Inc. de Copake à New-York fabrique des produits de haute qualité pour les essais en haute tension.

La gamme de produits est composée d’appareils : générateur d’essai de tenue à haute tension, diagnostic et d’équipements de localisation des défauts de câbles, de générateurs haute tension pour les postes électriques HT/MT et applications industrielles en production. Les produits offerts sont: générateurs de très basse fréquence (VLF) de 30 kV à 200 kV avec des fréquences de test variables de 0,1 Hz à 0,01 Hz. Ces modèles sont disponibles avec des capacités de charge de 0,4μƒ à 50μƒ. Nous proposons également la mesure de TAN delta et de décharges partielles pour le diagnostic des câbles d’alimentation; Ensembles de test d’intégrité neutres concentriques, générateur DC à haute tension testeurs d’isolement disponibles à partir de 37.5 kV jusqu’à 600 kV DC, ensemble de tests portables AC diélectriques de 3 kV à 300 kV AC avec des puissances allant jusqu’à 40 kVA. Ensembles de tests haute tension AC portables avec câble de sortie blindé jusqu’à 50 kV AC @ 3 KVA; Essai d’huile diélectrique à 100 kV AC pour les tests aux normes ASTM et CEI; Testeurs de moyen de levage pour ligne aériennes de 120 kV à 300 kV AC ; Localisateurs de défaut câbles / générateurs de surtension avec sorties d’énergie contrôlées jusqu’à 36 kV; TDR / Radar et dispositifs acoustiques de localisation. High Voltage Inc fabrique également divers instruments comme les moteurs et générateur de tests conçus sur mesure. Nous sommes à l’écoute de vos besoins ([email protected]) et seront heureux de vous aider dans votre application ou demande de devis. Notre site web donne accès aux documentations commerciales à l’adresse www.hvinc.com

HVPD

HVPD128 metroplex Business Park, BroadwayM50 24UW - SalfordUnited Kingdom

Tel: +44 (0) 161 877 6142Fax: +44 (0) 161 877 6139Email: marke [email protected]: www.hvpd.co.ukContact: Yasmin HASOON

Booth number/Stand 17 (Mazarin – Level 0)

High Voltage Partial Discharge Ltd (HVPD) are experts in On-line Partial Discharge (OLPD) insulation condition monitoring technology for high voltage (HV) cables and plant. Our OLPD technologies are used to support Condition-Based Management (CBM) schemes applied to both medium (3.3 kV to 36 kV) and high voltage (66 kV+) power networks. HVPD’s knowledge base is built upon the ongoing R&D work in conjunction with a number of UK Universities, carried out by HVPD’s Directors and Senior Engineers over the past 30+ years. We offer a complete range of PD test services, training and remote data analysis support to our customers in over 100 countries.

High Voltage Partial Discharge (HVPD) Ltd est dotée d’une expertise éprouvée dans le domaine de la détection et surveillance des décharges partielles (DP) en ligne (c.-à-d. réseaux en service et sous tension). Nos interventions et tests sont effectués sur des installations en service que ce soit en moyenne tension (MT), haute tension (HT) ou très haute tension (THT), de tension de 3,3 kV jusqu’à 750 kV.

Le vaste savoir-faire détenu par HVPD est fondé sur l’intense activité de recherche et développement (R&D) effectué par les directeurs de HVPD et leurs ingénieurs hautement qualifi és, en conjonction avec un certain nombre d’universités britanniques, au cours des 30 dernières années.

Nous offrons à nos clients dans plus de 100 pays une gamme complète de services de tests de DP, de la formation et support d’analyse des données à distance.

HIGH VOLTAGE TEST SYSTEMS HVTS

HIGH VOLTAGE TEST SYSTEMS41 rue Victor Schoelcher68200 - MulhouseFrance

Tel: +33 (0)3 89 33 17 70Fax: + 33 (0)3 89 33 17 79Email: [email protected]: www.hvts.fr Facebook: high voltage test systems HVTSContact : Bruno HAAS

Booth number/Stand 23 (Mazarin – Level 0)

HVTS is a major actor in the design of high voltage testing labs. We supply major international companies with shielded rooms, AC & HVDC sources, impulse generators and all related testing or measuring components required to test a large variety of equipment ranging from cable drums, transformers, switchgears, and more.

We supply turn-key projects, or custom-made equipment according to your needs anywhere in the world.

HVTS is the offi cial Passoni Villa testing equipment aftersales service supplier, but we maintain and service any testing equipment from any manufacturer even for equipment of more of 10 years of age.

We rent equipment and/or technical services, and also offer removal with reallocation of existing testing lab.

HVTS modernize existing equipment by supplying up to date control units, and sell selected reconditioned & guaranteed pre-owned HV testing equipment.

HVTS agit en tant qu’acteur privilégié dans le domaine de la conception de laboratoires d’essai haute tension. Nous fournissons les plus grandes entreprises internationales en cages de Faraday, sources de tension AC ou HVDC, en générateurs de choc, et tout autre appareillage de mesure lié aux essais HT de câbles, transformateurs, et bien d’autres.

Nous proposons des projets clés en main, ou des solutions sur mesure en fonction des besoins exprimés, et ce partout dans le monde. Nous sommes le partenaire offi ciel de Passoni Villa pour le service Après-Vente de ces équipements d’essai, et assurons la maintenance et l’entretien de n’importe quelle marque d’appareillage d’essai HT, même s’il a plus de 10 ans d’âge.

Nous louons également du matériel d’occasion ainsi que nos services techniques pour des missions ponctuelles, et effectuons des modernisations de matériel existant grâce à la conception de systèmes de contrôle commande évolués. Nous vendons également une sélection de matériel d’occasion reconditionné et garanti sur stock, et assurons la formation au personnel.

HIGHVOLT Prüftechnik Dresden GmbH

Marie-Curie Straße 1001139 - DresdenGermany

Tel: +49 351 8425 700Fax: +49 351 8425 679Email: [email protected]: www.highvolt.deContact: Michael Hensel, Dr. Stefan Schierig

Booth number/Stand 03 (Lobby – Level 0)

HIGHVOLT Prüftechnik Dresden GmbH is a long-established German-based company successfully operating in the international cable industry for many years.Mobile solutions for on-site testing are in particular high demand.The AC resonant test system with variable frequency, type WRV T is used for withstand voltage tests on laid cables and offers high fl exibility with regards to cable lengths and test locations alike. Cables up to one hundred meters long can be tested by connecting several test systems in parallel. The test system is installed on a trailer allowing easy transportation and is ready to operate within a few hours without the requirement of special assembly tools.Furthermore, the WRV T-system scores with low PD background noise level and its low-maintenance. As a result these systems also become more and more popular in factory testing of long cables (e.g. submarine cables). HIGHVOLT’s DC test system, type GPM is used for factory and on-site testing of HV cables and is characterized by a modular and compact design with the voltage divider integrated into the DC module for optimal space utilization. Container or trailer solutions are offered for on-site transportation. Due to its modular design, the test system can be upgraded to higher voltages at any time. Further highlights of this new product development are the fast polarity reversal and the additionally triggered discharge device.

L’entreprise allemande riche en traditions HIGHVOLT Prüftechnik Dresden GmbH travaille depuis de très nombreuses années avec succès pour l’industrie internationale du câble et propose notamment des solutions mobiles pour les essais sur place. Le système d’essai de la tension alternative avec fréquence variable de type WRV T se distingue par une grande fl exibilité, aussi bien en termes de longueurs de câble que de lieux d’essai. Pour les longueurs de câble allant jusqu’à des centaines de kilomètres, il est possible de commuter en parallèle plusieurs systèmes d’essai. Le système d’essai se transporte facilement sur une remorque. Pour l’installation sur site, qui souvent ne dure qu’une heure, aucune aide majeure n’est nécessaire. Par ailleurs, les systèmes d’essai WRV T concèdent un faible niveau de bruit de fond DP et nécessitent un très faible entretien. Grâce à ces propriétés exceptionnelles, ces systèmes d’essai sont également utilisés de façon renforcée pour l’essai de câbles longs (tels que câbles sous-marins) dans l’usine du fabricant. L’avantage du système d’essai de la tension variable HIGHVOLT de type GPM est sa conception modulaire et compacte. Il est utilisé pour les essais en usine et sur site de câbles à haute tension. Pour l’essai sur site, HIGHVOLT propose des solutions en containers et sur remorques. Un diviseur de tension intégré dans le module de tension redressée offre un design compact. La conception modulaire permet à tout moment au client d’étendre le système d’essai à des tensions plus élevées. HIGHVOLT propose désormais dans sa gamme des cabines-écrans récemment développées et aptes aux coussins d’air formant un très bon blindage et une résistance élevée à la corrosion.

IMERYS Graphite & Carbon

IMERYS Graphite & CarbStrada Industriale 126743 - BodioSuisse

Tel: +41 91 873 2010Fax: +41 91 873 2019Email: [email protected]: www.imerys-graphite-and-carbon.comContact : Eric Lachenait

Booth number/Stand 18 (Mazarin – Level 0)

IMERYS Graphite & Carbon (www.imerys-graphite-and-carbon.com), headquarted in Switzerland, has a strong tradition and history in carbon manufacturing. Its fi rst manufacturing operation was founded in 1908. Today, IMERYS Graphite & Carbon facilities produce and market a large variety of synthetic and natural graphites and conductive carbon blacks of consistent high quality.

IMERYS Graphite & Carbon is producing very clean, easy-dispersible, low moisture specialty conductive carbon black ENSACO®250G which is widely and successfully used in the manufacture of HV and MV power cable semicons (inner and outer semicon, strippable and fully bonded) and accessories. It is also a solution for making conductive jacketing, mainly for HV submarine cables, as well as the clean extra-conductive carbon black ENSACO®350G.

IMERYS Graphite & Carbon is also producing TIMREX® graphites which are useful additives for power cable integrity testing.

IMERYS Graphite & Carbon (www.imerys-graphite-and-carbon.com), dont le siège est en Suisse, a une forte tradition ainsi qu’une longue histoire dans la fabrication de carbone. Sa première opération industrielle a été fondée en 1908. Aujourd’hui, IMERYS Graphite & Carbon produit et commercialise une grande variété de graphites synthétiques et naturels et de noirs de carbone conducteurs de qualité constante et élevée.

L’ENSACO®250G, issu du procédé de fabrication particulier d’IMERYS Graphite &Carbone, est un noir de carbone conducteur très pur, de dispersion très aisée et non hygroscopique; celui-ci est largement utilisé pour la fabrication des gaines conductrices (blindage du conducteur et blindage de l’isolant, pelable et réticulé) et des accessoires pour câbles haute et moyenne tension. L’ENSACO®250G est également utilisé dans les jaquettes conductrices pour câbles haute tension, principalement sous-marins, de même que le noir de carbone extra-conducteur très pur ENSACO®350G.

IMERYS Graphite & Carbon produit aussi des graphites TIMREX® utilisés en tant qu’additifs pour le contrôle de l’intégrité des câbles de tension.

KINECTRICS Inc.

Kinectrics Inc. 800 Kipling Ave. Unit 2M8Z 5G5 - Toronto, ONCanada

Tel: + 416.207.6000 x6342Fax: + 416.207.6532Email: [email protected]: www.kinectrics.comContact: Cheryl Tasker-Shaw

Booth number/Stand 41 (Le Nôtre – Level 2)

Kinectrics is an established independent company providing advanced technical services to the electricity industry--worldwide. Our Transmission and Distribution (TDT) group utilizes specialized lab facilities and fi eld services to perform engineering, testing, and certifi cation for utilities and related industries.

Kinectrics delivers comprehensive services for HV/EHV transmission cables including pre-qualifi cation testing, on-site after laying commissioning testing, Partial Discharge (PD) testing, and maintenance testing. We use post-failure analysis techniques and methods to identify root cause failure. Kinectrics operates mobile Resonant Test Sets (RTS) rated at 260 kV at 83 amps. We have completed projects throughout North America, Mexico, Europe, and the Middle East, including commissioning cable systems of over 50 km in length while monitoring PD activity.

Kinectrics performs type testing of HV/EHV cables and accessories, and testing of all insulation types.

For MV / LV cable assessment, Kinectrics employs several methodologies with full diagnostic capabilities. Our expertise comprises over 30 years of experience with AC Hi-Pot and PD testing of 5-46 kV cables. www.kinectrics.com

Kinectrics, entreprise indépendante réputée, propose des services techniques avancés dans le secteur de l’électricité, et cela, dans le monde entier. Notre service de transport et de distribution (TDT) fait appel à des laboratoires spécialisés et à des services extérieurs pour réaliser des missions d’ingénierie, d’essais et de certifi cation pour les services publics et des secteurs connexes.

Kinectrics propose des services complets pour les câbles de transmission HT/UHT, y compris des essais de présélection, des essais de mise en service sur place après installation, des essais relatifs à la décharge partielle (DP), ainsi que des essais de maintenance. Nous appliquons des techniques et méthodes d’analyse après défaillance afi n d’identifi er l’origine des défaillances. Kinectrics utilise des groupes mobiles d’essais avec circuit résonant (RTS) d’une valeur nominale de 260 kV et 83 A. Nous avons mené à bien des projets à travers l’Amérique du Nord, le Mexique, l’Europe et le Moyen-Orient comme la mise en place de réseaux de câbles sur plus de 50 km tout en surveillant les DP.

Kinectrics effectue des essais de type sur les câbles HT/UHT et les accessoires, ainsi que des essais de tous les types d’isolant.

Concernant l’évaluation des câbles de faible ou moyenne tension, Kinectrics applique diverses méthodologies assorties de capacités de diagnostic complètes. Notre savoir-faire s’appuie sur plus de 30 ans d’expérience dans le domaine des essais portant sur le CA à haut potentiel et les DP des câbles entre 5 et 46 kV. www.kinectrics.com

LIOS Technology GmbH

LIOS Technology GmbHSchanzenstrasse 39 Building D9 - D1351063 - CologneGermany

Tel: +49 221 99887 0Fax: +49 221 99887 150Email: [email protected]: www.lios-tech.comContact: Lucien Antonissen

Booth number/Stand 28 (Mazarin – Level 0)

EN.SURE® Real Time Condition Monitoring for Electrical Transmission & Distribution Systems

The LIOS EN.SURE® DTS product line comprises a range of real-time, multimode and single mode fi bre optic based linear temperature measuring devices. LIOS offers Real Time Thermal Rating (RTTR, DCR) solutions for ampacity predictions of the power cable, subsea cable and overhead transmission line installation, transparently integrated with its fi eld proven DTS systems for the electrical T&D industry.

One single EN.SURE DTS unit provides fast temperature sensing profi les with high spatial resolution and temperature accuracy along the optical fi bre route with monitoring ranges up to 40 km per channel.

Surveillance en temps réel EN.SURE® pour les systèmes de transmission et de distribution électriques

La gamme de produits LIOS EN.SURE® DTS comprend une série d’instruments de mesure de la température en temps réel à fi bres optiques simple mode ou multimode. LIOS proposent des solutions de mesure de la température en temps réel (Real Time Thermal Rating ou RTTR, DCR) destinées aux prévisions du courant permanent admissible d’installations de câbles d’alimentation, de câbles sous-marins et de lignes de transmission aériennes, et intégrées en transparence avec leurs systèmes DTS éprouvés pour l’industrie de la transmission et de la distribution.

Une seule unité EN.SURE DTS fournit des profi ls rapides de relevé de la température avec une résolution spatiale élevée et une précision de température le long du trajet de la fi bre optique et des plages de surveillance atteignant 40 km par canal.

SebaKMT group Megger

SebaKMT group Megger23 Rue Eugène Henaff78190 - TrappesFrance

Tél: (0033) 01.30.16.08.90Fax: (0033) 01.34.61.23.77Email: [email protected]: www.sebakmt.comContact: Patrick Triphonoff

Booth number / Stand 20 (Mazarin – Level 0)

SebaKMT, a member of Megger group, is the world leader in manufacturing of test and measuring equipment for both electrical and telecom industries. The group offers worldwide to its customers a full set of services including the supply of equipment, but also after sales and calibration services, training to the operation of its equipment and to the maintenance of the electrical equipment installed on the network.

Megger group offers a complete solution of test and measurement:• Power Cable Fault Location Portable Equipment• Power Cable Fault Location Van mounted solutions• Cable diagnostic• Fault Location TDRs and Bridges• Telecom Cable Fault Location Equipment• Buried Cables and Piping Tracing and Location Equipment• Power Quality and Transients Recording and Analysis Solutions• Building Wiring Test Equipment• Test and Predictive Maintenance of Batteries, Circuit Breakers, Transformers, Rotating Machines, Protection Relays, Power Meters• Maintenance and Test Software

SebaKMT, membre du groupe Megger, est le leader mondial, fabricant d’équipements et systèmes de recherche et localisation des défauts et de diagnostic des câbles. Le groupe apporte, dans le monde entier, à ses clients des prestations complètes intégrant la fourniture des équipements, mais également le service après-vente, la vérifi cation d’étalonnage, la formation à l’utilisation des équipements et la formation à la maintenance des ouvrages et équipements électriques du réseau.

Le groupe Megger vous propose une solution de test et maintenance complète :• Systèmes portables de Recherche et Localisation de défauts sur les câbles d’énergie• Solutions de Recherche et Localisation de défauts sur les câbles d’énergie intégrées en véhicule• Diagnostic des câbles • Echomètres et Ponts de Localisation• Recherche et Localisation de défauts sur les réseaux de télécommunications cuivre• Traçage et localisation de câbles et canalisations enterrées• Enregistrement et Analyse de la qualité de l’énergie distribuée et des perturbations• Contrôle des installations électriques BT• Test et Maintenance Prédictive des Batteries, Disjoncteurs, Transformateurs, Machines Tournantes, Relais de Protection, Compteurs d’Energie• Logiciel de maintenance et test assistés

Mohaupt High Voltage GmbH

Mohaupt High Voltage GmbHGewerbepark 4 aA - 6142 - MiedersAustria

Tel: +43 5225 63758Email: [email protected]: www.mohaupt.hv.comContact: Karin Pieber

Booth number/Stand 04 (Mazarin – Level 0)

Mohaupt HV is a small team of experts located in Mieders, Innsbruck, Austria. The company was found in 2008 and it is owned by Peter Mohaupt who has more than 20 years of experience in the fi eld of high voltage. Our activities are the development and manufacturing of high voltage test equipment, specifi cally for transmission component manufacturers such as power cables, insulators, switchgears and others.

Mohaupt High Voltage (MHV) develops and manufactures all components in Austria. Besides measuring systems (such as PD detectors), there are no trading products. We offer the full range of HV sources (DC, VLF and AC) and their auxiliary components (feeders, dividers etc.). We are specialized on low loss HV reactors for laboratory testing as well as for on site testing, HV transformers, regulating transformers, DC and VLF test systems.

MHV is prepared for customer specifi c solutions and turn key projects - all engineering is done in house, so we can offer you a maximum of fl exibility to get an optimized solution for your individual purposes.

La société Mohaupt High Voltage GmbH est constituée d’une petite équipe d’experts travaillant sur le site de Mieders à proximité d’Innsbruck en Autriche. L’entreprise a été fondée en 2008 par son propriétaire, Monsieur Peter Mohaupt. Ce dernier jouit d’une expérience de plus de 20 ans dans le domaine de la technique de contrôle de haute tension.

Notre activité réside dans le développement et la fabrication de systèmes de contrôle de haute tension, en particulier pour les composants des éléments de transmission, comme par exemple les câbles, les isolateurs, les commutateurs et autres.

La société Mohaupt High Voltage développe et fabrique tous les composants sur son site en Autriche.

A l’exception des systèmes de mesure (comme par ex. les mesureurs de décharge partielle), il n’existe pas de produits vendus dans le commerce.

Nous proposons l’ensemble de la gamme de sources de haute tension (CC, VLF et CA) ainsi que leurs composants en aval (alimentation, répartiteurs, etc.).

Nous sommes spécialisés dans la fabrication de bobines à haute tension à faible perte destinées à des contrôles en laboratoire ou sur site.

Nous produisons en outre des transformateurs d’essai, des transformateurs à tension réglable ainsi que des systèmes de contrôle CC et VLF.

La société Mohaupt High Voltage GmbH est spécialisée dans l’élaboration de solutions spécifi ques pour les clients et de projets clé en main.

L’ensemble de l’ingénierie est réalisée au sein de l’entreprise ce qui permet d’obtenir un maximum de fl exibilité et des solutions sur mesure répondant aux exigences individuelles de nos clients.

NEXANS

NEXANS4-10 rue Mozart92587 - Clichy CEDEXFrance

Tel: +33 (0)1 55 62 70 00Fax: +33 (0)1 55 62 78 00Email: [email protected]: www.nexans.com

Booth number/Stand 32 (Mazarin – Level 0)

About Nexans

Nexans brings energy to life through an extensive range of cables and cabling systems that deliver increased performance for our customers worldwide. Nexans’ teams are committed to a partnership approach that supports customers in four main business areas: Power transmission and distribution (submarine and land), Energy resources (Oil & Gas, Mining and Renewables), Transportation (Road, Rail, Air, Sea) and Building (Commercial, Residential and Data Centers). Nexans’ strategy is founded on continuous innovation in products, solutions and services, employee development, customer training and the introduction of safe, low-environmental-impact industrial processes.

In 2013, Nexans created a Foundation to introduce sustained initiatives for access to energy for disadvantaged communities worldwide.

We have an industrial presence in 40 countries and commercial activities worldwide, employing close to 26,000 people and generating sales in 2014 of 6.4 billion euros.

For more information, please consult: www.nexans.com

A propos de Nexans

Nexans donne de l’énergie à la vie par une large gamme de câbles et de systèmes qui permet d’accroître l’effi cacité de ses clients dans le monde entier. En tant que partenaires, les équipes du Groupe interviennent au service de leurs clients dans quatre domaines principaux d’activités : le transport et la distribution d’énergie (réseaux terrestres et sous-marins), le secteur de l’énergie (pétrole et gaz, mines et énergies renouvelables), les transports (routiers, ferroviaires, aériens et maritimes) ainsi que le bâtiment .La stratégie de Nexans s’appuie sur l’ innovation permanente des produits, des services et des systèmes, mais aussi sur la motivation des équipes, l’information des clients et l’adoption de procédés industriels sûrs et respectueux de l’environnement.

En 2013, Nexans a créé une Fondation d’entreprise destinée à soutenir des actions en faveur de l’accès à l’énergie pour les populations défavorisées à travers le monde.

Présent industriellement dans 40 pays et avec des activités commerciales dans le monde entier, Nexans emploie près de 26 000 personnes. En 2014, le Groupe a réalisé un chiffre d’affaires de 6,4 milliards d’euros.

Pour plus d’informations : www.nexans.com

NKT CABLES GmbH & Co. KG

NKT CABLES GmbH & Co. KGDüsseldorfer Straße 40051061 - CologneGermany

Tel: +49 221 676 0Fax: +49 221 676 2646Email: [email protected]: www.nktcables.comContact: Helmut HÖLSCHER

Booth number/Stand 26 (Mazarin – Level 0)

nkt cables is one of the most experienced companies worldwide in the fi eld of energy transmission, convincing public utilities and the industry with innovative cables and accessories for low, medium and high voltage up to 550 kV. An innovative grid monitoring system is also part of nkt cables’ product range. Specialties are cables with very long lengths for offshore wind energy systems. nkt cables is a technology leader in the fi eld of catenary systems for very high speed railways. Low voltage building wires, installation cables, harnesses for the automotive industry and special wires for the industry complete nkt cables’ portfolio.

nkt cables est l’une des sociétés les plus expérimentées au monde dans le domaine des réseaux de transport et de distribution de l’énergie : un véritable attrait pour les services publics et l’industrie, qui repose sur des câbles et des accessoires innovants en basse, moyenne et haute tension (jusqu’à 550 kV). Un système novateur de surveillance des réseaux fait également partie des solutions apportées par nkt cables. Nous avons, parmi nos spécialités, des câbles de très grandes longueurs pour les liaisons offshore. nkt cables est également un leader technologique dans le domaine des systèmes de caténaires pour lignes ferroviaires à très grande vitesse. Des fi ls et câbles basse tension pour la construction et l’installation, des faisceaux de câbles pour l’industrie automobile ainsi que des fi ls et câbles spéciaux pour l’industrie complètent la gamme nkt cables.

OMICRON electronics GmbH

OMICRON electronics GmOberes Ried 16833 - KlausAustria

Tel: +43 59495Fax: +43 59495 9999Email: [email protected]: www.omicron.atContact:

Booth number/Stand 01 (Lobby – Level 0)

OMICRON is an international company serving the electrical power industry with innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confi dence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the product range complete.

Customers in more than 140 countries rely on the company’s ability to supply leading edge technology of excellent quality. Service centers on all continents provide a broad base of knowledge and extraordinary customer support. All of this together with our strong network of sales partners is what has made our company a market leader in the electrical power industry.

OMICRON est une société internationale qui développe et commercialise des solutions innovantes de test et de diagnostic pour l’industrie électrique. Les produits OMICRON offrent aux utilisateurs une fi abilité extrême dans l’évaluation de leurs équipements primaires et secondaires. Des services dans le domaine du conseil, de la mise en service, du test, du diagnostic et de la formation viennent compléter l’offre OMICRON.

Des clients dans plus de 140 pays bénéfi cient déjà de la capacité d’OMICRON à mettre en œuvre les technologies les plus innovantes dans des produits d’une qualité irréprochable. Les centres de support implantés sur tous les continents leur offrent en outre une expertise et une assistance de tout premier plan. Tout ceci, associé à un réseau solide de partenaires commerciaux a contribué à faire de notre société un leader sur son marché dans l’industrie électrique.

Omnisens

OmnisensRiond Bosson 31110 - MorgesSwitzerland

Tel: +41 21 510 2121Email: [email protected]: www.omnisens.comContact: Jane Rowsell

Booth number/Stand 09 (Mazarin – Level 0)

Interested in cable condition monitoring and optimization? Come and visit Omnisens, a leader in fi ber-optic distributed sensing. Find out more about Omnisens Cobra cable integrity monitoring solutions, which help optimize performance and monitor the condition of terrestrial and subsea high voltage power cables. Perhaps monitoring fatigue and the operating condition of subsea umbilicals interests you too.Through its dedicated team, Omnisens follows a project’s evolution from design, through project management, commissioning, data interpretation and on-site or remote service and support, delivering fully integrated, continuous asset integrity monitoring.With experience gathered from cable installations across the world, we would love to discuss your project!

La surveillance et l’optimisation de câble de puissance vous intéresse ? Venez nous voir ! Omnisens est leader dans le domaine de la mesure répartie par fi bres optiques ; nous vous parlerons de nos solutions « Omnisens Cobra » qui permettent de surveiller l’état de câbles haute tension terrestres et sous-marins et d’en optimiser les performances. Sans doute êtes-vous aussi intéressé par les conditions d’exploitation des ombilics sous-marins ou la gestion de leur surveillance en fatigue.

Chez Omnisens, une équipe expérimentée prendra en charge votre projet de la conception jusqu’à la mise en service, avec suivi du projet, interprétation des données, support technique sur site et à distance avec l’assurance de fournir à nos clients une solution complétement intégrée pour la surveillance continue d’infrastructures

Nous mettrons toute notre compétence acquise dans l’installation de systèmes de monitoring à fi bre optique pour la surveillance de câbles de par le monde au service de vos projets.

For a complete description of your company’s activities: www.omnisens.com

Onsite hv international ag

Onsite hv international agTöpferstrasse 56004 - LuzernSwitzerland

Tel: +41 41 500 51 20Fax: +41 41 500 05 51Email: [email protected]: www.onsitehv.comContact: G. Cejka

Booth number/Stand 24 (Mazarin – Level 0)

Onsite high voltage – the New Brand for the Electrical Energy Industry.

State of the art high voltage products and innovative power utility services – made in Switzerland.

Onsite high voltage is providing high-end testing and diagnostic tools for the electrical energy branch. We are the reliable partner for utilities, power suppliers and grid operators as well as producers of equipment for electrical grids.• Modern on-site testing and diagnostics for MV and (E) HV Power Cables using Damped AC (DAC) – testing technology• From 30 kV up to 500 kV• Advanced on-site diagnosis of power transformers with On-Load Tap Changer Using Transformer Diagnostic System

Phenix Technologies, Inc

Phenix Technologies, Inc75 Speicher DriveAccident MarylandMD 21520USA

Tel: +1 301 746 8118Fax: +1 301 895 5570Email: [email protected]: www.phenixtech.comContact:

Booth number/Stand 07(Mazarin – Level 0)

Phenix Technologies is a manufacturer of electrical testing equipment for testing transformers, motors, cables, circuit breakers, reclosers, insulation materials, switchgear, utility worker’s rubber goods/protective gear; offers a wide range of testing solutions

Our 80,000-square-foot headquarters located in Accident, Maryland, USA is a modern manufacturing facility where all aspects of electrical and mechanical design, software design, and production are performed.

Our engineers offer a unique blend of theoretical knowledge and practical experience that’s vital to the development of custom solutions for industry leaders. As members of world-wide professional and technical organizations, our engineers offer innovative solutions for any project.

Phenix Technologies has 40 years of experience and ISO 9001 quality certifi cation.

Our Service and Calibration Department travels worldwide to assist customers during and after equipment installation to ensure optimum equipment performance and customer satisfaction.

Phenix Technologies offers a wide range of testing solutions for utilities, transformer and motor manufacturers/repair shops, cable manufacturers, independent testing companies, original equipment manufacturers.

Phenix Technologies est un fabricant d’équipement de test électrique et offre une large gamme de solutions de test pour les manufactures et utilisateurs de produit de haute tension comme: transformateurs, moteurs, câbles, disjoncteurs, réenclencher, matériaux d’isolation, de commutation, les produits de protection en caoutchouc

Phenix est basé dans la ville de Accident en Maryland and notre usine avec son 80 000 mètre carrés de dimension est une usine de fabrication moderne où tous les aspects de la conception électrique et mécanique, de logiciels et de la production sont effectuées selon la certifi cation ISO 9001.

Phenix a un bureau des ingénieurs qui offre un mélange unique de connaissances théoriques et d’expérience pratique qui est vitale pour le développement de solutions sur mesure pour les nos clients dans l’industrie de la haute tension.

Phenix est membres d’organisations professionnelles et techniques à l’échelle mondiale et a 40 années d’expérience dans son marché à niveau international offrent des solutions innovantes pour toutes les projets.

Le nôtre département d`étalonnage e les notre bureau de service avec des voyages à travers le monde pourront aider les clients avant et après l’installation de l’équipement pour assurer une performance optimal et la satisfaction des clients.

Phenix Technologies propose une large gamme de solutions de test pour les sociétés électriques, les producteurs des transformateur, machines tournantes, Câbles, le Bureau de de réparation et aussi les sociétés de service et mise en ligne des systèmes de haute tension.

PFISTERER SAS

PFISTERER SAS35 avenue d’Italie68110 - IllzachFrance

Tel: + 33 (3) 89 31 90 29Fax: + 33 (3) 89 31 90 28Email: michel.bartissol@pfi sterer.frWebsite: www.pfi sterer.frContact: Michel BARTISSOL

Booth number/Stand 21 (Mazarin – Level 0)

PFISTERER is a leading independent manufacturer of cable accessories and overhead line accessories for the sensitive interfaces in energy networks. The business group is headquartered in southern German Winterbach in Stuttgart.

PFISTERER develops, produces and sells internationally successful solutions for voltage levels from 110 V to 850 kV; With a full range of products for use in energy networks, consultation, assembly and training, the manufacturer is a valued partner worldwide for companies involved in energy supply, operates production sites in Europe, China, South America and South Africa and has sales branches in 19 countries in Europe, Asia, Africa, South America and the USA. The business group currently employs around 1,400 staff members.

PFISTERER est un fabricant indépendant, leader dans les domaines très pointus des accessoires de câbles de réseaux de transport électrique et de lignes aériennes. Le siège social du groupe est situé à Winterbach, près de Stuttgart, dans le sud de l’Allemagne.

PFISTERER développe, fabrique et commercialise avec succès à l’international, des solutions adaptées à des niveaux de tension allant de 63 à 850 kV.

Grâce à une gamme complète de produits dans les domaines des réseaux électriques, au conseil, aux prestations de montage et de formation, PFISTERER est un partenaire apprécié dans le monde entier par les entreprises impliquées dans la production d’énergie électrique, la construction d’usines et l’électrifi cation des réseaux ferroviaires.

PFISTERER possède des usines implantées en Europe, en Chine, en Amérique du Sud et en Afrique du Sud et dispose de fi liales commerciales dans 19 pays d’Europe, d’Asie, d’Afrique, d’Amérique du Sud ainsi qu’aux USA. Le Groupe PFISTERER emploie près de 1 400 personnes de par le monde.

POURTIER - Gauder Group

POURTIER - Gauder GroupParc de l’Esplanade1 rue Enrico Fermi77400 - Saint-Thibault-des-VignesFrance

Tel : +33 (0)1 64 21 84 00Fax: +33 (0)1 64 26 61 10Email: [email protected]: www.pourtier-setic.comContact: Philippe Letout

Booth number/Stand 15 (Mazarin – Level 0)

POURTIER – Gauder Group offers excellent and reputed experience in designing and manufacturing stranding machines and cabling machines for Power cables production. More than 1500 lines (i.e. 10000 individual machines) are in production worldwide.

POURTIER has taken the leadership in the fi eld of stranding and cabling of high voltage and extra high voltage cable for AC or DC cable: high performance stranding line type RFS 630 and RFS 800 for stranding of High voltage aerial cables as well as advanced stranding lines for “MILLIKEN” (AC cables) or “concentric”(DC Cables) construction up to 3000 sqmm using the most performant compacting system. Also stranding of trapezoidal aluminium wires has been developed to produce the new type of conductor for highest performance of aerial cables. These conductors are using central core made of steel (ACSS/TW and ACSR/TW) or made of composite material (ACCC™).

Drum twister laying lines are used for laying up of MV, HV and EHV power cables with take up drums as big as 5 meter in diameter and 50 tons in weight; lines for Milliken are equipped with the latest innovation including waterproofi ng systems in line and most performant correction system to ensure the perfect quality of MILLIKEN conductor for underground cables.

POURTIER – Gauder Group offre son expérience dans le développement et la fabrication de machines d’assemblage pour câbles de puissance. Plus de 1500 lignes (i.e. 10000 machines individuelles) sont en production dans le monde.

POURTIER est leader sur le marché de l’assemblage des câbles haute tension et très haute tension AC ou DC : la ligne de câblage type RFS 630 et RFS 800 pour les câbles aériens haute tension ainsi que les lignes d’assemblage hautes performance pour la construction de câbles « Milliken » (câbles AC) ou « concentriques » (câbles DC) jusqu’à 3000 mm² en utilisant le système de compactage le plus poussé. D’autre part, le câblage de fi ls d’aluminium trapézoïdaux a été développé pour produire de nouveaux types de conducteurs aériens plus performants. Ces conducteurs utilisent un porteur central en acier (ACSS/TW et ACSR/TW) ou en matériau composite (ACCC™).

Les lignes d’assemblage à réception tournante sont utilisées pour l’assemblage de câbles de puissance moyenne tension, haute tension et très haute tension avec des enrouleurs jusque 5 mètres de diamètre et de 50 tonnes : les lignes pour câbles Milliken sont équipées avec les innovations les plus récentes incluant les systèmes d’étanchéité longitudinale et le système de correction sophistiqué afi n d’assurer une qualité parfaite du conducteur Milliken pour les câbles souterrains.

Power Diagnostix Systems GmbH

Power Diagnostix Systems GmbHVaalser Straße 25052074 - AachenGermany

Tel: +49 241 74927Fax: +49 241 79521Email: [email protected]: www.pdix.comContact: Markus Söller

Booth number/Stand 43 (Le Nôtre – Level 2)

Power Diagnostix provides instruments and engineering services for high-voltage diagnostic applications. Our series of digital PD detectors is used for evaluation of electrical insulation by electric utilities, manufacturers, and R&D institutes worldwide. In addition to digital PD detectors, Power Diagnostix produces instruments for commissioning tests of high voltage systems, automated control of HV tests, fi ber optic connections for analog or digital signal transmission, and for other applications in high voltage labs.

Especially for the application of PD testing on MV, HV, or EHV cables Power Diagnostix offers various solutions. The ICMfl ex, ICMcompact and the TDAcompact, instruments for partial discharge and for loss factor measurements, are compatible with different power supplies such as VLF test systems, resonant test sets, or others. Various sensors, like differential foil sensors, CTs for cross bonding links, or embedded sensors on cable joints and terminations can be used for permanent monitoring with the SPECmonitor.

Power Diagnostix Systems GmbH produit une gamme d’appareils pour les diagnostics en haute tension. La série des détecteurs de décharges partielles est utilisée dans le monde entier pour évaluer l´état de l’isolation électrique d’équipements installés sur site, en usine ou laboratoires de R&D. En complément de ces détecteurs, Power Diagnostix produit des appareils d’exploitation de tests sur système haute tension, contrôle automatisé de tests HT, connexion par fi bre optique pour transmission de signal analogue ou digital et autres applications en laboratoire haute tension.

Spécialement pour l’application de test PD sur MV, HV ou câbles EHV, Power Diagnostix offre diverses solutions. L’ICMfl ex, ICMcompact, et TDAcompact, appareils de mesure de décharge partielle et de perte de facteur sont compatibles avec divers fournisseurs d’énergie tel les systèmes de test VLF, sets de test de résonance ou autres. Divers capteurs comme les capteurs à fi lm différentiel, les CT pour raccordement de câble ou capteurs intégrés sur joints de câble et raccordement peuvent être utilisés pour la surveillance permanente avec le SPECmonitor.

PRYSMIAN Group

Prysmian GroupViale Sarca 22220126 - MilanoItaly

Tel: +39 0264491Fax: +39 0264491Email: [email protected]: www.prysmiangroup.comContact: Energy R&D Director – Luca De Rai

Booth number/Stand 06 (Mazarin – Level 0)

Prysmian Group is world leader in the energy and telecom cables and systems industry. With more than 130 years of experience, sales of nearly €7 billion in 2014, some 19,000 employees across 50 countries and 89 plants, the Group is strongly positioned in high-tech markets and offers the widest possible range of products, services, technologies and know-how. It operates in the businesses of underground and submarine cables and systems for power transmission and distribution, of special cables for applications in many different industries and of medium and low voltage cables for the construction and infrastructure sectors. For the telecommunications industry, the Group manufactures cables and accessories for voice, video and data transmission, offering a comprehensive range of optical fi bres, optical and copper cables and connectivity systems. Prysmian is a public company, listed on the Italian Stock Exchange in the FTSE MIB index.

Prysmian Group est leader mondial de l’industrie des câbles et systèmes d’énergie et télécommunication. Fort de plus de 130 années d’expérience, des ventes de près de 7 milliards d’euros en 2014, avec 19000 employés dans 50 pays et 89 usines, le groupe est fortement positionné sur les marchés de haute technologie pour lesquels il offre une large gamme de produits et services.

Il opère dans les métiers des câbles et systèmes sous-marins et terrestres pour la transmission et la distribution d’énergie, des câbles spéciaux pour les applications industrielles en moyenne et basse tension, pour la construction et les infrastructures. Dans l’industrie des télécommunications, le groupe fabrique des câbles et accessoires pour la transmission de la voix, des données et des images (VDI), avec une gamme complète de fi bres optiques, câbles cuivre et à fi bre optique, et connectivité. Prysmian est une société publique cotée à la bourse italienne, à l’indice FTSE MIB.

RTE – Réseau de Transport d’Electricité

RTE – Réseau de Transport d’ElectricitéTour Initiale – 1 Terrasse BelliniTSA 4100092919 Paris La Défense cedexFrance

Phone: + 33 (0)1 41 02 18 96Fax: + 33 (0)1 41 02 17 45Email: [email protected]: www.rte-france.comContact: Magali HUET

Booth number/Stand 16 (Mazarin – Level 0)

RTE, Réseau de Transport d’Electricité, is the French transmission system operator. Its public service mission is to provide to all its customers economical, reliable and clean access to electrical power. RTE connects its customers using an adapted network and provides them with targeted and valuable solutions, considering economic effi ciency, environmental respect and security of supply. For this purpose, RTE manages, maintains and develops high and extra-high voltage transmission system. RTE is responsible to keep the balance between supply and demand in a reliable and safe electricity system. RTE conveys electricity throughout France, from power generation facilities (French and Europeans) to industrial consumers directly connected to the transmission grid, and to distribution grid providing the link between RTE and end users. With 100,000 km of 63,000 to 400,000 volt lines and 48 cross-border lines, the transmission system managed by RTE is the largest one in Europe. RTE has 8,500 employees.

RTE, Réseau de Transport d’Electricité, est une entreprise de service. Notre mission fondamentale est d’assurer à tous nos clients l’accès à une alimentation électrique économique, sûre et propre. RTE connecte ses clients par une infrastructure adaptée et leur fournit tous les outils et services qui leur permettent d’en tirer parti pour répondre à leurs besoins, dans un souci d’effi cacité économique, de respect de l’environnement et de sécurité d’approvisionnement en énergie. A cet effet, RTE exploite, maintient et développe le réseau à haute et très haute tension. Il est le garant du bon fonctionnement et de la sûreté du système électrique. RTE achemine l’électricité entre les fournisseurs d’électricité (français et européens) et les consommateurs, qu’ils soient distributeurs d’électricité ou industriels directement raccordés au réseau de transport. 105 000 km de lignes comprises entre 63 000 et 400 000 volts et 48 lignes transfrontalières connectent le réseau français à 33 pays européens, offrant ainsi des opportunités d’échanges d’électricité essentiels pour l’optimisation économique du système électrique. RTE emploie 8 500 salariés.

Scapa UK Ltd

Scapa UK LtdManchester Road, Ashton-under-LyneGreater Manchester OL7 0EDUnited Kingdom

Phone: +44 161 301 7400Fax: +44 161 301 7475Email: [email protected]: www.scapa.com/en/cable-Contact: Jeff TateGlobal Market Manager - Cable Materials

Booth number/Stand 44 (Le Nôtre – Level 2)

Scapa has over 102 years of experience in the development manufacture and supply of cable protection tapes to the global power cable industry. This gives Scapa a pedigree you can count on. With this know-how as a backdrop Scapa now has one of the widest ranges of water blocking, woven cable tapes and cable components in the industry and is a key supplier and reference partner to most of the world’s manufacturers of power and data cables.There are three ways to buy cable tapes from Scapa:Core range – Choose one of our proven cable wrapping tapes from one of the most extensive ranges in the industryMade to Measure – If one of our standard products doesn’t match your application requirements, within our portfolio of cloths, coatings, super absorbent polymers and processes, we can produce something that doesInnovation Projects – If a more advanced solution or a new way of doing things is needed for the next generation of cable protection, our engineers and R&D team can work in partnership to deliver the ideal solutionAs part of the Scapa Group with production sites, R&D facilities and logistics all over the world, you can rely on us to match your needs globally and locally.

Scapa a plus de 102 ans d’expérience dans le développement et la fabrication de rubans spécialisés pour la confection des câbles à travers le monde. Cela procure à notre entreprise des fondements sur lesquels vous pouvez compter. Grace à ce savoir-faire, Scapa a maintenant l’une des gammes les plus larges en rubans gonfl ants hydro bloquants, en rubans tissés et en composants pour câble dans cette l’industrie. Scapa est un fournisseur et partenaire clé pour la majorité des fabricants mondiaux de câbles de puissance et de transmission de données.Il y a trois façons d’acheter du ruban adhésif chez Scapa :Gamme Principale – Choisissez dans nos rubans spécialisés pour câble parmi la gamme la plus large du marché.Fait sur mesure - Si l’un de nos produits standard ne correspond pas à vos exigences d’application, parmi notre gamme de tissus, des revêtements ou des polymères super absorbants, nous pouvons ajuster le produit en fonction de vos besoins.Projets Innovation - Si une solution plus avancée ou un nouveau projet est nécessaire pour la prochaine génération de câbles, nos ingénieurs et notre équipe R & D peuvent vous fournir la solution idéale.Faisant partie intégrante de Scapa avec les sites de production, des services R&D et de la logistique dans le monde, vous pouvez compter sur nous afi n de satisfaire vos besoins localement et mondialement.

SENSORNET

Booth number/Stand 27 (Lobby – Level 0)

SICAME Group

SICAME Group1 rue B. Lachaud – BP n° 119231 - PompadourFrance

Tel: + 33 (5) 55 73 89 00Fax: + 33 (5) 55 98 53 51Email: [email protected]: www.sicame.fr

Booth number/Stand 10 (Mazarin – Level 0)

Groupe Sicame companies design, manufacture and market:• equipment for the construction and maintenance of electric, public lighting and telecommunications networks, such as accessories having a mechanical

function (reinforcing brackets for poles, anchoring and suspension clamps for cables, spacers, vibration dampers, etc.) and accessories having an electrical function (connectors, connections, etc.),

• a complete range of equipment to enable “linemen” and installers to works in complete safety when working on high and low voltage structures, and to ensure the protection of equipment and individuals against the direct and indirect effects of lightning,

• complete ranges of industrial connector products (non-insulated connectors, pre-insulated connectors, loose and coiled connectors, cabling accessories) and tools for electricians and manufacturers.

The Group’s offering is backed up by after-sales services and training courses.

Today the Group provides more than 20,000 products approved by the most important public enterprises in electricity and telecommunications as well as by electrical installers, automotive, aerospace and rail companies.

Les entreprises du Groupe Sicame conçoivent, fabriquent et commercialisent :• des équipements pour la construction et la maintenance de réseaux électriques, d’éclairage public et de télécommunications, à savoir des accessoires

à fonction mécanique (ferrures d’armement des poteaux, pinces d’ancrage et de suspension des câbles, entretoises, amortisseurs de vibrations,…) et des accessoires à fonction électrique (connecteurs, raccords…),

• une offre complète d’équipements pour permettre aux « lignards» et aux installateurs de travailler en toute sécurité lors des interventions sur ouvrage hors et sous tension, et pour assurer la protection des biens et personnes contre les effets directs et indirects de la foudre,

• des gammes complètes de produits de connectique industrielle (cosses nues, préisolées, en vrac et en bandes, accessoires de câblage) et outillage pour les électriciens et les industriels.

Le Groupe a une offre enrichie de Services après-vente et de Formations .

Aujourd’hui, il propose plus de 20 000 produits agréés par les plus grandes entreprises publiques d’électricité, de télécommunications, par les installateurs électriques les sociétés automobiles, aérospatiales et ferroviaires.Inscription obligatoire

SMEETS S.A.

SMEETS S.AChaussée de Mons, 1891600 - Sint-Pieters-LeeuwBelgique

Tel: +32 23771140Fax: +32 23772407Email: [email protected]: Jean-François de VIGNE

Booth number/Stand 19 (Mazarin – Level 0)

SMEETS S.A.(since 1921) is the exclusive agent/importer of Loypos in Europe, North & South America, India, Africa and the Middle-East. SMEETS has his own slitting unit for tapes.

LOYPOS Corp. is the dedicated manufacturer of high quality semiconductive and non-conductive tapes for high voltage and extra high voltage cable. LOYPOS also produces WATERBLOCKING woven tapes with high tensile strength.

LOYPOS and SMEETS have been business partners for more than a decade, exporting their tapess throughout the 5 continents as well as ensuring a presence in South-Korea, Belgium, India and the USA.

SMEETS (since 1921) also exports ‘’SOFT WATERBLOCKING YARNS’’ and many other components for the cable industry.

SMEETS S.A. (depuis 1921) est l’agent/importateur exclusif de LOYPOS pour l’Europe, L’Amérique du Nord et du Sud, L’inde, L’Afrique et le Moyen-Orient. SMEETS possède son propre centre de découpe pour rubans.

LOYPOS CORP. fabrique des rubans semi-conducteurs et non-conducteurs de très haute qualité pour les câbles Haute Tension et Extra Haute Tension. LOYPOS offre aussi des rubans tissés étanches à très haute résistance mécanique.

LOYPOS et SMEETS travaillent en partenariat depuis plus de 12 ans, exportent leurs rubans sur les 5 continents et assurent une présence en Corée du Sud, en Belgique, en Inde et aux USA.

SMEETS (depuis 1921) exporte aussi ses ‘’FILINS GONFLANTS’’ et ses autres composants pour l’industrie du câble.

STRI

STRIBox 707771 80 - LudvikaSweden

Tel: +46 240 79500Fax: +46 240 15029Email: [email protected]: www.stri.seContact: Carolyn Stanley

Booth number/Stand 25 (Mazarin – Level 0)

STRI is a leading independent company specializing in high voltage testing and consulting within high voltage technology and power system applications. Our specialists and engineers deliver solutions to help improve performance, effi ciency, reliability, profi tability, and to minimize impact on the environment. Our clients are power grid companies, power producers, industries, railway companies, authorities, agencies and manufacturers of electrical equipment all over the world.

Our world class accredited high voltage laboratory and climate test hall are equipped to handle tests on products with system voltages up to 800 kV AC and DC. We have extensive experience in testing AC and DC sea and land cables. We also offer the following tests: • Pollution ; • Accelerated ageing ; • Test of line confi guration ;• Measurement of E-fi eld distribution ; • Delection of corona activities with UV-video camera. In addition to our unique ion migration test facility, we also have facilities for PQ-, material- and mechanical testing for cables.

STRI est une société indépendante de premier plan spécialisée dans les activités d’essai et de conseil en haute tension pour les applications de technologie haute tension et de systèmes d’alimentation. Nos spécialistes et ingénieurs offrent des solutions pour améliorer les performances, l’effi cacité, la fi abilité, la rentabilité et minimiser l’impact sur l’environnement. Nos clients sont des compagnies de réseau électrique, des producteurs d’électricité, des industries, des entreprises de chemin de fer, des administrations, des agences et des fabricants d’équipements électriques partout dans le monde.

Notre hall de test climatique et notre laboratoire haute tension accrédités et de classe mondiale sont équipés pour effectuer des tests sur les produits avec des tensions système allant jusqu’à 800 kV CA et CC. Nous possédons une vaste expérience des tests des câbles sous-marins et terrestres AC et DC. Nous proposons également les tests suivants : • pollution ; • vieillissement accéléré ; • test de confi guration de ligne ; • mesure de la distribution du champ électrique ; • détection des activités corona avec caméra vidéo UV. En plus de notre unique centre de test de la migration des ions, nous disposons également d’installations pour PQ, essais matériels et mécaniques pour les câbles.

Novinium / UtilX Europe GmbHNovinium / UtilX Europe GmbHMühlengrund 131675 - BückeburgGermany

Tel: +49 5722 28525 0Fax: +49 5722 28525 19Email: [email protected]: www.cablecure.deContact: Martin Hesse

Booth number/Stand 31 (Lobby – Level 0)

UtilX Europe GmbH, located in Bückeburg, Germany is the European branch of USA based Novinium Inc. Novinium is the global leader in life-extension technologies for underground power cables. It offers proprietary, patented CableCURE® injection services, CableWISE® online, non-destructive cable assessment services and other reliability and testing services worldwide through its direct service operations and authorized licensees.

Cab leCURE® technology is an underground transmission and distribution cable rehabilitation process that signifi cantly extends the useful life of underground power cable beyond its estimated service life. Only in Europe over 3 million system meter successfully have been treated with CableCURE®.

CableWISE® technology provides a detailed assessment of the condition of medium or high voltage cable systems. CableWISE® is not just partial discharge detection, but an online, non-destructive condition assessment technique.

UtilX Europe GmbH, avec siège social à Bückeburg, Allemagne, est la succursale européenne de Novinium Inc.Novinium est le leader mondial en technologie d’extension de vie pour les câbles de moyenne et haut tension. Novinium offre les services brevetés : CableCURE® service d’injection des câbles, CableWISE® mesure en tension et non destructive avec appréciation, et des autres services de test et en augmentation de fi abilité. Novinium agit mondial en service direct et avec les partenaires autorisées.

La technologie CableCURE® est un processus de réhabilitation de câbles sous terrain qui augment signifi ant la durée de vie opérationnelle au-delà de son estimation. Seul en Europe plus de 3 millions de mètres système ont était traitée avec succès avec CableCURE®.

La technologie CableWISE® donne une appréciation détaille de l’état des câbles et le système des câbles en moyenne, haut et très haute tension. CableWISE® est plus qu’une system de détection de décharge partielle : CableWISE® est non destructive et fournit une appréciation complète de système.

WIRESCAN AS

WIRESCAN ASKveldroveien 7NO-1407 - VinterbroNorway

Tel: +47 47 90 88 00Email: [email protected]: www.wirescan.noContact: Pal RØSJØ

Booth number/Stand 11 (Mazarin – Level 0)

Wirescan AS delivers products and services for diagnosis, condition assessment and monitoring of electrical cables and umbilicals. With Wirescan’s test equipment LIRA® Portable and the LIRA® technology (LIne Resonance Analysis) the company provide Cable Fault Location, Cable Condition Assessment, and Cable Condition Monitoring for Utilities (Power Transmission & Distribution), Oil & Gas, Offshore Wind, Nuclear Power Plants, and Cable Manufacturers industries globally.

Wirescan´s patented LIRA® Technology is a non-destructive test method to monitor the global progressive degradation of the cable insulation due to harsh environment conditions (high temperature, humidity, radiation, etc.), and detect local degradation of the insulation material due to mechanical impacts or local abnormal environment conditions.Wirescan´s patented LIRA® Technology was developed by the Institute for Energy Technology (IFE) in Halden, Norway, as part of an OECD Project, to fulfi ll the need for improved cable diagnostic tools at Nuclear Power Plants.Present shareholders in Wirescan AS are Siemens Venture Capital Energy GmbH, SåkorninVest II AS/Procom Venture AS, IFE Venture AS, and Schlumberger BV.Wirescan AS is qualifi ed by Sellihca and Achilles JQS, and member of INTSOK Norwegian Oil & Gas Partners and Subsea Valley.

Wirescan AS fournit des produits et services pour le diagnostic, évaluation de l’état et de la surveillance de câbles ombilicaux et électriques. Avec l’équipement d’essai de Wirescan LIRA® portable et la technologie de LIRA® (Ligne résonance Analyse) la société de fournir de défaut de câble Lieu, Câble évaluation de l’état, et Cable Condition Monitoring for Utilities (Power Transmission & Distribution), Oil & Gas, éolien offshore, l’énergie nucléaire Plantes, et fabricants de câbles secteurs au niveau mondial.Wirescan’s breveté LIRA® Technology est une méthode de contrôle non destructif pour surveiller la dégradation progressive mondial de l’isolation du câble en raison de conditions diffi ciles de l’environnement (haute température, humidité, rayonnement, etc.), et de détecter la dégradation locale du matériau d’isolation en raison aux impacts mécaniques ou des conditions environnementales locales anormales.Wirescan’s technologie brevetée LIRA® a été développé par l’Institut de technologie de l’énergie (IFE) à Halden, en Norvège, dans le cadre d’un projet de l’OCDE, pour répondre au besoin d’amélioration des outils de diagnostic de câble dans les centrales nucléaires.Actionnaires présents dans Wirescan AS sont Siemens Venture Capital Energy GmbH, SåkorninVest II AS / Procom Venture AS, IFE Venture AS, et Schlumberger BV.Wirescan AS est qualifi é par SELLIHCA et Achille JQS, et membre du INTSOK Norwegian Oil & Gas Partners et Subsea Valley.

Jicable’15 - Topics1. Materials, New Materials and Ageing Assessment in AC and DC

► Materials characterization: electric, physical and chemical, ► New materials for cables and accessories ► Nanotechnologies : nanotubes, nano-fi lled polymers, … ► Bio-materials and environment-friendly materials ► Ageing laws: methods, experimentation, validity

2. Cables and Accessories Design - Modelling ►Electrical, thermal and thermo-mechanical design ►AC resistance of Conductors ►Steady state and dynamic conditions ►Ampacities ►Sheath bonding, Grounding and protection ►Cable characteristics and cable modelling ►Associated computer codes and validation ►Voltage and current system coordination ► Issues related to Cable integration in networks

3. Testing Methods: Electrical and Non Electrical ► Defi nitions ► Selection criteria ► Validity ► Development tests, evaluation, prequalifi cation tests, type tests, acceptance and after laying tests ► Low frequency testing ► PD testing as maintenance tool ► Testing of Conductor Connectors

4. Cables, Environment and Sustainable Development ► Impact of cables on the environment (overhead, underground, submarine) ► Magnetic fi eld limitation and health effects ► Environment friendly design ► Impact of the environment on cable systems (tropical, etc.) ► Corrosion ► Derating in metallic structures ► Specifi c technologies ► Lifecycle analysis ► End-of-life treatment methods ► Developments in cable regulations ► Coexistence of cables and nearby systems (eg. Telecommunications)/Shared structures

5. Diagnosis, Maintenance, Remaining Life Estimation and Management ►Methods for assessing the properties and characteristics of materials and possible impact on the performances of cables and accessories ► Monitoring ► On-line diagnosis of materials ► Fault location ► Methods of examination ► Expert systems ► Remaining life estimation in different environments: temperature, electric fi elds, ionizing irradiations,... ► Life extension

6. Economy of Cable Systems ► Cost reduction and optimisation of cable systems ► Experience in service ► Shared installation structures: multipurpose pre-installed ducted systems in roads, galleries, tunnels, … ► Cost reduction and optimisation of civil works and laying techniques ► Financial investments ► Availability and insurances

7. LV and MV Cable Systems ► LV and MV cables and accessories (insulated underground and overhead networks)

► New materials, environmentally concerned design, ► Developments in manufacturing processes and techniques ► Laying methods, experience in service and quality assurance, comparative performances of cables buried with and without mechanical protection ► Operating conditions, thermo-mechanical behaviour, reliability, failure analysis, operating life extension ► Cables for smart grids ► Use of telecommunication cables in conjunction with LV and MV cable circuits, powerline communications ► Safety in case of fi re ► Standardization

8. HV and EHV AC Cable Systems ► HV and EHV AC cables and accessories ► New developments ► Forced cooling, water cooling, … ► New materials, environmentally oriented design ► Developments in manufacturing processes and techniques ► Laying methods, technical specifi cations, shared installation structures, quality assurance, prevention of third party damage, new innovative laying methods with reduction of the duration of works and of the disturbance of the side residents ► Operating conditions, maintenance, service experience, reliability, failure analysis operating life extension, improving performances and operating at design limits, upgrading and uprating ► Technical and economical optimisation (high stresses, taking into account reliability, availability, temperature in normal, overload and short-circuit conditions, etc.) ► Integration in networks ► Use of telecommunications cables in conjunction in HV and EHV links, powerline communications ► Safety in case of fi re ► Maintaining the integrity of accessories ► Prevention of Third Party damage ► Standardization

9. HVDC Cable Systems ► HV and EHV DC cables and accessories ► Transition joints ► Phenomena associated at the interfaces, cables and accessories ► Space charge measurements (interfaces and materials) ► Aging and reliability ► Simulations and numerical models ► Testing: investigation, development, Qualifi cation, Type Tests, Routine and Sample tests … ► Qualifi cation procedures including Extension of Qualifi cation ► Operational experience ► Change from AC to DC

10. Submarine Cable Systems ► AC and DC cable systems ► Mechanical Testing ► Technical and economical optimization for the different parts of the installation ► Cable systems for offshore wind power plants and oil platforms ► Dynamic cables ► Use of Aluminium ► DC cables and accessories ► Laying, embedding and protection techniques ► Operating conditions, feedback ► Availability of submarine links ► Integration in the network

11. Cables for the Future ► Gas-insulated cables (SF6 and other gases)

Technologies under development EHV / UHV cables Long-distance use Laying and civil engineering Repair methods

► Superconducting links

Feedback from the fi rst High Temperature Superconducting links (HTSC) Prospects for new High Temperature Superconductors (HTSC) Low-temperature properties of insulating materials Technical-economical evaluation Questions related to the integration of superconducting links in standard networks Other new underground power transmission systems

12. Industrial and Special Cables ► Technologies and installation (eg. land, underwater, overhead and spatial cables); wind power plants, PV photovoltaic / solar energy cables, nuclear power plants, etc.) ► Substation cables, generation station cables, LV secondary cables, … ► Cables with improved fi re behaviour and fi re resistance ► Cables submitted to harsh external conditions: high mechanical stresses, chemical attack, ionizing irradiations,… ► Other Special Cables: aerospace, automotive, rolling Stock, railway, marine, lift and crane cables, oil & gas, airport beaconing, … ► New materials ► Developing manufacturing techniques

13. Technical challenges encountered with cable systems ► Integration of long cables (high power) in networks (compensation, static stability and dynamics of networks, distribution of the power fl ows in the mixed networks), ► Generation output with cable systems: compensation, no load voltage, ► Long length lines for bulk power transmission (tens of km to hundred km), how to ensure reliability and operability.

Young Researchers Contest

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: F

Chairman: GUBANSKI Stanislaw; Chalmers University of Technology, SwedenRapporteurs: NOTINGHER Petru; Institut d’Électronique du Sud - Université Montpellier 2,

CNRS, FranceTEYSSEDRE Gilbert; CNRS / Laplace, Université P. Sabatier, France

F2.01 The investigation of conduction current and dissipation power distributions in XLPE under HVDC at high temperature environment

FUJITOMI Toshiyuki, KATO Tsuyoshi, MIYAKE Hiroaki, TANAKA Yasuhiro; Tokyo City University, Tokyo, Japan

F2.02 Study of XLPE dielectric properties for HVDC cables during combined thermal and electrical ageing

HASCOAT Aurélien, CASTELLON Jérôme, AGNEL Serge; Institut d’Electronique du Sud, Université Montpellier 2, Montpellier, FranceFRELIN Wilfried, EGROT Philippe; EDF R&D, Les Renardières, FranceHONDAA Pierre, AMMI Soraya; RTE, Paris-La Défense, FranceLEROUX Dominique, ANDERSSON Johan, ERIKSSON Virginie; BOREALIS, Stenungsund, Sweden

F2.03 Infl uence factors of fi eld inversion in HVDC cables

FUCHS Karsten, BERGER Frank; Ilmenau University of Technology, Ilmenau, GermanyFISCHER Andreas, DRUMMER Dietmar; Institute of Polymer Technologie Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen-Nürnberg, Germany

F2.04 Analysis of technical planning principles for partial underground cabling in meshed extra-high voltage Grids

VEERASHEKAR Kishan; Friedrich Alexander University Erlangen-Nuremberg, Erlangen, GermanySIEBELS Carsten; TenneT TSO GmbH, Bayreuth, GermanyLA SETA Piergiovanni; Siemens AG, Erlangen, GermanyFUCHS Bernhard; RWTH Aachen University, Aachen, Germany

F2.05 Eco-friendly nanodielectrics with enhanced thermal and electrical properties for HVDC cable insulation

ZHOU Yao, HE Jinliang, HU Jun, DANG Bin; State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing, China

F2.06 Effect of state of stress on space charge accumulation in silicon rubber insulation of HVDC cables

GUO David; State Key Lab of Control and Simulation of Power Systems and Generation Equipment, Dept of Electrical Engineering, Tsinghua University, Beijing, China

F2.07 Spatially-resolved measurement and diagnostic method for power cables using interference characteristics of travelling waves

FISCHER Erik, WEINDL Christian; Institute of Electrical Energy Systems, University of Erlangen-Nuremberg, Erlangen, Germany

F2.08 Modeling of viscoelastic dynamic bending stiffness for VIV analysis of submarine cables

HEDLUND Johan; ABB AB, High Voltage Cables, Karlskrona, Sweden

F2.11 DC cable modeling and High Voltage Direct Current grid grounding system

LOUME Dieynaba, BERTINATO Alberto, NGUYEN TUAN Minh; SuperGrid Institute, Villeurbanne, FranceRAISON Bertrand; G2elab, Saint Martin d’Hères, France

F2.12 Development and engineering application of ±160 kV XLPE to three-terminal VSC HVDC project in China

HOU Shuai, FU Mingli, ZHAO Linjie; Electric Power Research Institute of China Southern Power Grid, Guangzhou, China

F2.14 Relationship between breakdown strengths and trapping parameters of serviced XLPE cables

LIU Ning, CHEN George; University of Southampton, Southampton, UKXU Yang; Xi’an Jiaotong University, Xi’an, China

F2.15 Effects of voltage magnitude on growth characteristics of electrical trees in silicone rubber

ZHANG Yunxiao, ZHOU Yuanxiang, SCHNETTLER Armin; State Key Lab of Control and Simulation of Power Systems and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing, ChinaZHANG Xu; North China Electric Power Research Institute Co Ltd, Beijing, China

F2.16 Optimization of High Voltage electrodes and HV cable accessories design by using MATLAB and FEMM

TUNA Enis; Demirer Kablo, Bilecik, Turkey

F2.17 Infl uence on measured conductor AC resistance of High Voltage cables when the shield is used as return conductor

HÖGÅS Marcus, RYDLER Karl-Erik; SP Technical Research Institute of Sweden, Borås, Sweden

F2.18 Measurement of the conductor temperature in power cable production

FRECHEN Henning, PUFFER Ralf, SCHNETTLER Armin; RWTH Aachen University, Aachen, GermanyBRAMMER Gregor; Forschungsgemeinschaft für Elektrische Anlagen und Stromwirtschaft e.V., Mannheim, Germany

F2.19 Improvement of ampacity ratings of Medium Voltage cables in protection pipes by comprehensive consideration and selective improvement of the heat transfer mechanisms within the pipe

BALZER Constantin, HINRICHSEN Volker; TU Darmstadt, High Voltage Laboratories, Darmstadt, GermanyDREFKE Christoph, STEGNER Johannes, SASS Ingo; TU Darmstadt, Geothermal Science and Technology, Darmstadt, GermanyHENTSCHEL Klaus; Bayernwerk / e-on, Regensburg, Germany

F2.20 Characterization of Transparent Fluorescent Silicones for Optical Monitoring of High-Voltage Cable Accessories

KUCHARCZYK Krzysztof, BANASZAK Szymon, GAWRYLCZYK Konstanty; West Pomeranian University of Technology, Szczecin, PolandLEISTNER André; Polymerics GmbH, Berlin, GermanySIEBLER Daniel; BAM Federal Institute of Materials Research and Testing, Berlin, GermanyHEIDMANN Gerd; IPH Institut “Prüffeld für Elektrische Hochleistungstechnik” GmbH (CESI Group), Berlin, Germany

F2.21 Predicted rating system for directly buried cables

HUANG Ru, PILGRIM James A., LEWIN Paul L.; University of Southampton, Southampton, UKSCOTT David, BLACKWELL Anna, MORRICE Daniel; National Grid plc, Warwick, UK

F2.22 Space charge behaviors of PP/EPDM/ZnO nanocomposites for recyclable HVDC cable

DANG Bin, HE Jinliang, HU Jun, ZHOU You; State Key Lab of Power Systems, Dept. of Electr. Eng., Tsinghua Univ., Beijing, China

F2.23 Estimating the losses in three core submarine power cables using 2D and 3D FEA simulations

STURM Sebastian, PAULUS Johannes; University of Applied Sciences Würzburg-Schweinfurt, Schweinfurt, GermanyBERGER Frank; Ilmenau University of Technology, Ilmenau, GermanyABKEN Karl-Ludwig; Norddeutsche Seekabelwerke GmbH /General Cable, Nordenham, Germany

F2.24 Thermal impedance of insulated overhead power cables heated by joule losses and solar radiation

CHATZIPANAGIOTOU Panagiotis, TOSCANO Alexandros Saverio, PAPAGIANNOPOULOS Ioannis; Aristotle University of Thessaloniki, Department of Electrical and Computer Engineers, Thessaloniki, GreeceDE MEY Gijbert; Ghent University, Department of Electronics and Information Systems, Ghent, BelgiumWIECEK Boguslaw; University of Lodz, Institute of Electronics Technical, Lodz, PolandMARANDA Witold, NAPIERALSKI Andrzej; Technical University of Lodz, Department of Microelectronics and Computer Science, Lodz, Poland

F2.25 Measurement and modeling of surface charge accumulation on insulators in HVDC gas insulated line (GIL)

ZHANG Boya, WANG Qiang, ZHANG Guixin; Tsinghua University, Beijing, China

Jicab

le’15

- At

a gl

ance

Roo

m A

Roo

m B

Roo

m C

Roo

m D

Roo

m E

Roo

m F

(P

oste

r Ses

sion

)O

ther

s

Satu

rday

Jun

e 20

th

16:0

018

:00

Wel

com

e of

dele

gate

sSu

nday

Jun

e 21

st

10:0

018

:30

Wel

com

e of

dele

gate

s13

:30

17:0

0Tu

toria

ls: T

1,

T2, T

3,T4

& T

517

:15

18:3

0W

elco

me

Lect

ure

18:3

020

:00

Wel

com

e Co

ckta

ilM

onda

y Ju

ne 2

2nd

09:0

010

:30

Sess

ion

A0O

peni

ng S

essio

n

11:0

012

:30

Sess

ion

A1HV

and

EHV

Cab

le

Syst

ems

Sess

ion

B1Su

bmar

ine

Cabl

e Te

chno

logy

Sess

ion

C1Re

mai

ning

Life

Es

ma

on

of LV

and

Sess

ion

D1Te

s n

g m

etho

ds:

PD m

easu

rem

ents

Sess

ion

E1Ec

onom

ics o

f Cab

le

Syst

ems

14:3

016

:00

Sess

ion

A2HV

: Ins

talla

on

met

hods

Sess

ion

B2De

sign

of

Subm

arin

e Li

nes

Sess

ion

C2Sy

stem

relia

bilit

y m

anag

emen

tSe

ssio

n D2

Relia

bilit

y di

agno

s c

sSe

ssio

n E2

Cabl

e ra

ngs

ca

lcul

a o

ns 1

Sess

ion

F2Yo

ung

Rese

arch

ers

Cont

est

16:3

018

:30

Sess

ion

A3HV

Ope

ra n

g Co

ndi

ons

Sess

ion

B3

Subm

arin

e ca

ble

tes

ng

&

Sess

ion

C3

Diag

nosis

met

hods

Sess

ion

D3Th

erm

o-m

echa

nica

l Tes

ng

Sess

ion

E3Ca

ble

ra n

gs

calc

ula

ons

2Tu

esda

y Ju

ne 2

3rd

09:0

010

:30

Sess

ion

A4HV

AC

New

dev

elop

men

tsSe

ssio

n B4

Inst

alla

ons

of

Subm

arin

e lin

esSe

ssio

n C4

MV

cabl

e di

agno

sisSe

ssio

n D4

On

site

and

Labo

rato

ry Te

sts 1

Sess

ion

E4M

odel

ling

11:0

012

:30

Sess

ion

A5HV

cab

le in

tegr

a o

n in

ne

twor

k

Sess

ion

B5Su

bmar

ine

Cabl

esGe

nera

l

Sess

ion

C5HV

and

EHV

cabl

e di

agno

sisSe

ssio

n D5

On

site

and

Labo

rato

ry Te

sts 2

Sess

ion

E5Ca

ble

and

acce

ssor

ies D

esig

n,

aplic

a o

ns

14:3

016

:00

Sess

ion

A6HV

DCCa

bles

& S

yste

ms

Sess

ion

B6M

ater

ials

for H

VDC

cabl

esSe

ssio

n C6

Mai

nten

ance

Sess

ion

D6Sp

ecifi

c Te

s n

g Tr

ends

1Se

ssio

n E6

Tech

nica

l Cha

lleng

es

Sess

ion

F6.1

Mat

eria

ls, A

gein

gSe

ssio

n F6

.2Di

agno

sis, M

aint

enan

ce,

16 :3

018

:00

Sess

ion

A7Te

s n

g &

Qua

lifi c

a o

n of

HV

DC C

able

Sys

tem

sSe

ssio

n B7

New

mat

eria

ls

Sess

ion

C7Ca

bles

and

syst

ems,

m

odel

ling

and

asse

ssm

ent

Sess

ion

D7Sp

ecifi

c Te

s n

g Tr

ends

2Se

ssio

n E7

Mat

eria

l rel

ated

spec

ial

feat

ures

Jicab

le’1

5“S

oiré

e”Fr

om 1

8:30

Wed

nesd

ay J

une

24th

09:0

010

:30

Sess

ion

A8Te

s n

g of

HVD

C Sy

stem

sSe

ssio

n B8

Mat

eria

l for

Ac

cess

orie

s and

Se

ssio

n C8

Impr

ovem

ent o

f Ca

ble

Ra n

gsSe

ssio

n D8

Tes

ng

eval

ua o

nsSe

ssio

n E8

New

cab

le a

nd

acce

ssor

ies m

oni-

11:0

012

:30

Sess

ion

A9M

ater

ials

and

Spac

e Ch

arge

sSe

ssio

n B9

Mat

eria

l Pe

rform

ance

sSe

ssio

n C9

Spec

ial C

able

s Av

ioni

csSe

ssio

n D9

Envi

ronm

ent a

nd

sust

aina

bilit

y 1

Sess

ion

E9De

sign

of LV

MV

cabl

e sy

stem

s

Sess

ion

F9.1

LV, M

V, H

V, E

HV &

futu

re

cabl

es -

Sess

ion

F9.2

Cabl

es a

nd A

cces

sorie

s De

sign

Mod

ellin

g14

:30

16:0

0Se

ssio

n A1

0HV

DC T

rans

ient

Ph

enom

ena

Sess

ion

B10

Cabl

es fo

r the

Fu

ture

Sess

ion

C10

Indu

stria

l and

Spec

ial C

able

sSe

ssio

n D1

0En

viro

nmen

t and

su

stai

nabi

lity

2Se

ssio

n E1

0Ch

alle

ngin

g En

viro

nmen

t16

:30

18:0

0Se

ssio

n A1

1 Cl

osin

g se

ssio

n

Thur

sday

Jun

e 25

th

09:0

018

:00

Tech

nica

l Visi

ts

V1, V

2 &

V3

Sunday June 21st, 2015 - 17:15

AW Welcome lecture

Sunday June 21st, 2015 - 17:15 - 18:30 - Room: A

AW.i Welcome Lecture: “Brazil’s situation in terms of energy - Challenges and perspectives”

MATOS DE ARAUJO Josias; Vice President CNB CIGRE, Director of regulation, Eletrobras, Brazil

Monday June 22nd, 2015 - 09:00

A0 Opening session

Monday June 22nd, 2015 - 09:00 - 10:30 - Room: A

A0.i Opening Lecture: “European Electricity Transmission Infrastructure: a Key to the Energy Transition”

BORNARD Pierre; Deputy CEO of RTE, Chairman of the board of ENTSO-E, France

Monday June 22nd, 2015 - 11:00

A1 HV and EHV cable systems

Monday June 22nd, 2015 - 11:00 - 12:30 - Room: A

Chairman: ARGAUT Pierre; CIGRE SC B1, France (CIGRE)Rapporteur: MAMMERI Mohamed; General Cable / Silec Cable, France

A1.1 Worldwide experiences and challenges with EHV XLPE cable projects 330 kV to 500 kV

WEINLEIN Andreas, PETERS Ulrich, LAAGE Uwe, MEMMER Horst; Südkabel GmbH, Mannheim, Baden Württemberg, Germany

A1.2 The network connection of Niehl 3 CCPP - The fi rst 380 kV long-distance cable project in Germany since the Bewag projects in 2000

SCHELL Fabian; FICHTNER, Stuttgart, GermanyUHLENKÜKEN Heinz; Rheinische Netzgesellschaft, Cologne, Germany

A1.3 138 kV cable system qualifi cation to IEC 60840-2011 / ICEA S-108-720-2012 / AEIC CS-9-06 / IEEE 48-2009 / IEEE 404-2012

GANATRA Ravi; CME Wire and Cable, Suwanee, USAPERKEL Josh; NEETRAC, Atlanta, Georgia, USAUZELAC Milan; G & W Electric, Chicago, USAZAMUDIO José; Viakable, Monterrey, Mexico

A1.4 Qualifi cation of a 150 kV transition joint for connecting external gas pressure three-core cable with extruded single core cables

VAN ROSSUM Jos, BARTHOLOMEUS Robert, OLTMANS Maurice, GEENE Henk, BODEGA Riccardo; Prysmian Netherlands B.V., Delft, The NetherlandsROSS Rob, MOUSAVI GARGARI Shirma; TenneT, Arnhem, The NetherlandsVAN DOELAND Wouter; Energy Solutions, Delft, The Netherlands

A1.5 PQ test and fi rst 230 kV cable system project in Mexico

MAXIMO Juan, SALDIVAR Candelario; Viakable Operaciones, San Nicolas de los Garza, Mexico

A1.6 Cable installation in mountainous areas, example of a successful installation and service

BOSSE Anika, BÜSCHER Astrid, EWERT Walter; nkt cables, Cologne, GermanyLACKNER Johannes, BRANDSTÖTTER Erich; VERBUND Hydro Power GmbH, Vienna, Austria

B1 Submarine cable technology

Monday June 22nd, 2015 - 11:00 - 12:30 - Room: B

Chairman: JEROENSE Marc; ABB AB, High Voltage Cables, SwedenRapporteur: BOUDINET Nathalie; RTE, France

B1.1 Use of aluminium conductors in submarine power cables

WORZYK Thomas, LÅNGSTRÖM Sonny; ABB AB, Karlskrona, Sweden

B1.2 Latest technologies for submarine cable protection and repair

HASEGAWA Mamoru; Sumotomo Electric Industries, ltd., Osaka, Japan

B1.3 Potential use of new water tree retardant insulation in submarine cables

CREE Stephen; Dow Electrical & Telecommunications Europe, Horgen, Zurich, SwitzerlandCARONIA Paul, PERSON Timothy; Dow Electrical & Telecommunications USA, Collegeville, Pennsylvania, USA

B1.4 Development of 320 kV subsea/underground HVDC extruded cable system

SHIGEMORI Naoto, MORI Hiroki, YAGI Yukihiro; VISCAS Corporation, Ichihara, Chiba, JapanSAKAI Yasuhiro; VISCAS Corporaation, Hiratsuka, Kanagawa, Japan

B1.5 Key technical research on submarine optic fi ber and power composite cable with long length, three cores & high voltage

ZHANG Jianmin; Zhongtian Technology Submarine Cable Co., Ltd, Nantong, ChinaXIE Shuhong; Zhongtian Technology Group Co., Ltd, Nantong, China

B1.6 The Oslofjord project - The world’s fi rst installed 420 kV submarine cable connection combining SCFF cables and XLPE cables with fl exible factory joints

OLDERVOLL Froydis, JENSEN Geir; Statnett SF, Oslo, NorwaySLÅTTEN Stein Arne, ELDERS Jostein, KALDHUSSÆTER Einar; Nexans Norway AS, Oslo, Norway

C1 Remaining life estimation of LV and MV cables

Monday June 22nd, 2015 - 11:00 - 12:30 - Room: C

Chairman: SINISUKA Ngapuli Irmea; Institut Teknologi Bandung, IndonesiaRapporteur: DENIZET Isabelle; General Cable, France

C1.1 Assessment of overheating in XLPE MV cable joints by partial discharge measurements

EBERG Espen, HVIDSTEN Sverre; SINTEF Energy Research, Trondheim, NorwayBERGSET Kristina I.; The Norwegian University of Science and Technology (NTNU), Trondheim, Norway

C1.2 Risk on failure, based on PD measurements in actual MV PILC and XLPE power cables

QIAN Yizhou; Technical University Eindhoven, Eindhoven, The NetherlandsWAGENAARS Paul, STEENNIS Fred; DNV GL, Arnhem, The NetherlandsHARMSEN Denny; Alliander, Arnhem, The NetherlandsSOEPBOER Piet; Enexis, Arnhem, The NetherlandsBLEEKER Pascal; Locamation, Enschede, The Netherlands

C1.3 Main objectives and results of the EU project ADVANCE with focus on aging assessment of cable insulation used in nuclear power plants through electrical measurements

MOREAU Christophe, FRANCHET Maud; EDF R&D, Moret-sur-Loing, FranceFABIANI Davide, VERARDI Luca, MONTANARI Gian-Carlo; UNIBO, Bologna, ItalyFRANÇOIS Sandrine; EDF SEPTEN, Villeurbanne, France

C1.4 Prediction of power cable failure rate based on failure history and operational conditions

SACHAN Swati, ZHOU Chengke, BEVAN Geraint, ALKALI Babakalli; Glasgow Caledonian University, Glasgow, UK

C1.5 Dielectric loss evolution for miniature cables with PE insulation through various stages of degradation

BERNIER Simon, DRAPEAU Jean-François, JEAN Daniel; Hydro-Québec (IREQ), Varennes, Québec, Canada

C1.6 Aging management for XLPE and EPR medium voltage cables in nuclear plant environments

BANERJEE Sarajit, ROUISON David, SEDDING Howard; Kinectrics Inc., Toronto, Ontario, Canada

D1 Testing methods: PD measurements

Monday June 22nd, 2015 - 11:00 - 12:30 - Room: D

Chairman: FENGER Mark; Prysmian Group, CanadaRapporteur: SIMÉON Éric; Nexans, France

D1.1 Partial discharge measurements in the sub-VLF-range

RETHMEIER Kay; Kiel University of Applied Sciences, Kiel, GermanyBLANK Rudolf; b2 electronic GmbH, Klaus, Austria

D1.2 The application of PD monitored AC voltage test in Beijing 500 kV power cable lines acceptance

AN Jianqiang, LI Zhen, DONG Yi, ZHU Zhanwei, SUN Changqing; Beijing Electric Power Company, Beijing, ChinaXIAO Chuanqiang; SINDIA Instruments, Beijing, China

D1.3 Long-term experiences and review with offl ine and online PD measurements on-site on EHV XLPE cable systems 330 kV to 500 kV

WEINLEIN Andreas, PETERS Ulrich, SCHROEDER Gero, HAERING Dominik; Südkabel GmbH, Mannheim, Baden Württemberg, Germany

D1.4 Results of 10 years after installation tests combined with PD detection on MV cable-systems

DE VRIES Frank, SMIT Jacco; Alliander, Alkmaar, The NetherlandsVAN SLOGTEREN John; Liander, Arnhem, The Netherlands

D1.5 PD characteristics under the aspect of different voltage wave shapes and frequencies

PETZOLD Frank, GOETZ Daniel, PUTTER Hein; Seba Dynatronic, Baunach, GermanySTEPHAN Marco, MARKALOUS Sacha; Hagenuk KMT, Radeburg, Germany

D1.6 On-site combination of withstand voltage testing and partial discharge measurement for XLPE power cable accessories

ELFARASKOURY Adel; Egyptian Electricity Holding Company, Extra High Voltage Research Centre, Cairo, Egypt

E1 Economics of cable systemsMonday June 22nd, 2015 - 11:00 - 12:30 - Room: E

Chairman: PENSERINI Paul; RTE, FranceRapporteur: GIFFARD Philippe; SYCABEL, France

E1.1 Electrothermal coordination in cable based transmission grids operated under market based conditions

OLSEN Rasmus, RASMUSSEN Carsten; Energinet.dk, Fredericia, DenmarkHOLBOELL Joachim; Technical University of Denmark, Kgs. Lyngby, DenmarkGUDMUNDSDOTTIR Unnur Stella; Dong Energy, Fredericia, Denmark

E1.2 Copper or aluminium cable conductors, broadly compared in a life-cycle perspective

BOONE Wim, KACKER Arnav, BAL Remco; DNV GL, Arnhem, Gelderland, The Netherlands

E1.3 Operating a 10 kV cable on a system voltage of 20 kV: the long term test

SMIT Jacco, DE VRIES Frank, SEBREGTS Ger; Alliander, Arnhem, The NetherlandsBOONE Wim; DNV GL, Arnhem, The Netherlands

E1.4 Cable selection challenges

BALLOUR Sami, ALHAMMADI Khadija; DUCAB, Dubai, United Arab Emirates

E1.5 Effi cient project management of high voltage underground cable systems against self-evident facts

DUBREUIL Michel, POMBOURCQ Hervé; RTE, Paris, France

E1.6 The use of life cycle cost analysis to determine the most effective cost of installation 500 kV of Java-Sumatra power interconnection system

NUGRAHA Herry, SILALAHI Zivion; PLN Indonesia, Jakarta, IndonesiaSINISUKA Ngapuli; ITB, School of Electrical Engineering and Informatics, Bandung, Indonesia

Monday June 22nd, 2015 - 14:30

A2 HV: installation methodsMonday June 22nd, 2015 - 14:30 - 16:00 - Room: A

Chairman: GILLE Alain; Verbraeken Construction NV, BelgiumRapporteur: RAUD Jean-Louis; SERCE, France

A2.1 Production, installation and commissioning of two 380 kV underground lines for the pump-storage plant project of Linth Limmern (Swiss Alps)

BIOLLEY Claude, MOUCHANGOU Christian; Nexans Suisse SA, Cortaillod, Switzerland

A2.2 Installation and commissioning of Patuxent river crossing (HDD, 1.4km) project in US

JOO Jaeyun, JEON Seung-ik, KIM Byungsoo; LS Cable & System, Gumi, Republic of Korea

A2.3 138 kV insulated cable system for temporary connection of transmission lines and substations

SILVESTRE Gustavo, CAPARROZ Sergio; AES Eletropaulo, São Paulo - SP, BrazilLOPES Julio Cesar, ARAUJO Simone, PINHEIRO Walter; TAG Inovação Tecnológica, São Paulo - SP, Brazil

A2.4 Analysis between open cut and trenchless methods for installation of underground high voltage systems

CRESTAN Giovanni, BATISTA Vital, FUJIHARA Jody, CHAVES Claudimar, KRAUSS Sanzio; Sedra Engenharia, São Paulo - SP, Brazil

A2.5 Non-offset design of cables in manhole considering the mechanical behavior of XLPE cables in duct

KANG Yeon-woog, KANG Ji-won, JANG Tae-in, JUNG Chae-kyun, YOON Jong-keun; KEPCO, Daejeon, Republic of Korea

A2.6 Study on thermal backfi ll materials for directly buried HV cables

BURCEANU Monica; Laborelec, Linkebeek, BelgiumVAN DER BORGHT Pieter; Elia, Brussels, Belgium

B2 Design of submarine lines

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: B

Chairman: VERCELLOTTI Uberto; CESI S.p.A., ItalyRapporteur: FRANCHET Maud; EDF R&D, France

B2.1 AC transmission systems for large scale and remote offshore wind farms

OLSEN Espen, HATLO Marius; Nexans Norway AS, Halden, NorwayKARLSTRAND Johan; JK Cablegrid Consulting AB, Karlskrona, Sweden

B2.2 Comparison of losses in an armoured and unarmoured three phase cable

FARIA DA SILVA Filipe, LETH BAK Claus; Aalborg University, Aalborg, DenmarkEBDRUP Thomas, F. JENSEN Christian; Energinet.dk, Erritsø, Denmark

B2.3 Design and manufacturing of ±200 kV HVDC submarine power cable in Zhoushan fl exible DC transmission project

HU Ming, ZHANG Jianmin; Zhongtian Technology Submarine Cable Co., Ltd, Nantong, ChinaXIE Shuhong; Zhongtian Technology Group Co., Ltd, Nantong, China

B2.4 Development of dynamic submarine MV power cable design solutions for fl oating offshore renewable energy applications

MARTA Marco, MUELLER-SCHUETZE Sven, OTTERSBERG Heiner; Norddeutsche Seekabelwerke GmbH / General Cable, Nordenham, Lower Saxony, GermanyISUS Daniel; General Cable Sistemas, Manlleu, Catalunya, SpainJOHANNING Lars, THIES Philipp R.; University of Exeter, Penryn, UK

B2.5 Design studies for French submarine links

BOUDINET Nathalie, CHARVET Jean, DORY Matthieu, LAURE Emmanuelle, MOINDROT Vincent, LESUR Frédéric; RTE, Paris, France

B2.6 Wet designs for HV submarine power cables

KARLSTRAND Johan; JK Cablegrid Consulting AB, Karlskrona, SwedenFURUHEIM Knut-Magne; Nexans Norway AS, Halden, NorwayHVIDSTEN Sverre, FAREMO Hallvard; SINTEF Energy, Trondheim, Norway

C2 System reliability management

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: C

Chairman: MAXIMO Juan; Viakable Operaciones, MexicoRapporteur: CABAU Matthieu; RTE, France

C2.1 Repeated fi eld tests - Utility case studies of the value of trending

HAMPTON Nigel, PERKEL Josh; NEETRAC, Atlanta, Georgia, USAHERNANDEZ Jean Carlos; Universidad de Los Andes, Merida, Venezuela

C2.2 Performance optimization of underground power cables using real-time-thermal-rating

OLSCHEWSKI Martin, HILL Wieland; LIOS Technology GmbH, Cologne, Germany

C2.3 Improving cable system reliability by monitored withstand diagnostics - Featuring high effi ciency at reduced test time

BAWART Manfred; BAUR Prüf und Messtechnik, Sulz, AustriaFERRER CAMPS Carlos, GAMEZ Joseba Koldo, VILLALONGA Antoni; Endesa Distribucion Electrica, Palma de Mallorca, SpainFERRERES José Luis; MARTIN BAUR S.A., Barcelona, Spain

C2.4 Design and implementation of a DTS system for 220 kV cable temperature monitoring and fi re detection in a 9.4 km tunnel

CHEN David; Transpower New Zealand Limited, Auckland, New ZealandWILDASH Bob; Wildash Consulting Limited, Paraparaumu, New Zealand

C2.5 Underground power cable health indexing and risk management

MEIJER Sander, VAN DER WIELEN Peter, VERMEER Mischa, WETZER Jos, DE HAAN Evert; DNV GL, Arnhem, The Netherlands

C2.6 Belgian experience with real time temperature system in combination with distributed temperature sensing techniques

LEEMANS Pieter; Elia, Brussels, Belgium

D2 Reliability diagnosis

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: D

Chairman: ORTON Harry E.; Orton Consulting Engineers International, CanadaRapporteur: MUSQUIN Max; General Cable ( Silec Cable), France

D2.1 Diagnostics of control and instrumentation cables in nuclear power plant via time-frequency domain refl ectometry with optimal reference signal

LEE Chun-kwon, CHANG Seung-jin, JUNG Moon-kang, HAN Yee-jin, LEE Geon-seok, PARK Jin Bae, SHIN Yong-june; Yonsei University, Seoul, Republic of Korea

D2.2 Long lengths transmission power cables on-site testing up to 500 kV by damped AC voltages

SEITZ Paul, QUAK Benjamin; Seitz Instrumetns AG, Niederrohrdorf, SwitzerlandGULSKI Edward; onsite hv solutions ag, Luzern, SwitzerlandWILD Manuel; Stuttgart University of Technology, Stuttgart, GermanyDE VRIES Frank; Liandon B.V., Alkmaar, The Netherlands

D2.3 New integrated solution for DAC and VLF testing and diagnosis of distribution power cable circuits

QUAK Benjamin, SEITZ Paul P.; Seit Instrumetns AG, Niederrohrdorf, SwitzerlandGULSKI Edward; onsite hv solutions ag, Luzern, SwitzerlandDE VRIES Frank; Liandon B.V., Alkmaar, The Netherlands

D2.4 End of life of underground medium voltage cables on Pacifi c islands

HENNUY Blandine, PIOT Sam; Laborelec, Linkebeek, BelgiumCOULON Sébastien; EDT, Papeete, French Polynesia

D2.5 Expanding the performance of on site testing with frequency tuned resonant test systems

ERDENIZ Sadettin, GÜRSOY Kemal; EMELEC Electrical Engineering &Trading PLC, Istanbul, TurkeyMOHAUPT Peter, GEIGER Toni; Mohaupt High Voltage, Mieders, Austria

D2.6 Effectiveness and comparability of condition tests on MV cables

BUYS Peter, VAN HOUWELINGEN Dirk; Stedin BV, Rotterdam, The Netherlands

E2 Cable ratings calculations 1

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: E

Chairman: RITTINGHAUS Dirk; Energycableconsult, GermanyRapporteur: RÉMY Christian; Prysmian Câbles & Systèmes, France

E2.1 A guide for rating calculations of insulated cables

DE WILD Frank; DNV GL, Arnhem, The NetherlandsVAN ROSSUM Jos; Prysmian, Delft, The NetherlandsANDERS George; Anders Consulting, Toronto, Ontario, CanadaBRIJS Bruno; Elia Engineering, Brussels, BelgiumBASCOM Rusty; Electrical Consulting Engineers, P.C., Schenectady, New York, USAPILGRIM James A.; University of Southampton, Southampton, UKCOELHO Marcio; Procable, São Paulo - SP, BrazilHUELSKEN Georg; nkt cables, Cologne, GermanyKULJACA Nikola; Prysmian Group, Milan, ItalyMARTINSSON Bo; ABB, Karlskrona, SwedenNAM Seok-hyun; LS Cable ltd., Gyeongbuk, Republic of KoreaRAKOWSKA Aleksandra; Poznan University of Technology, Poznan, PolandRÉMY Christian; Prysmian Group, Gron, FranceTAKAHASHI Tsuguhiro; CRIEPI, Nagasaka, JapanCORSARO Pietro; Brugg Kabel AG, Brugg, Aargau, SwitzerlandFALCONER Antony; Aberdare Cable, Port Elisabeth, South AfricaGONZÁLEZ Alberto; GasNatural Fenoza, Madrid, SpainWAITE Francis; National Grid Plc, Warwick, UK

E2.2 Gravitational cooling of cable installations

BRAKELMANN Heinrich; BCC Cable Consulting, Rheinberg, GermanyWASCHK Volker; nkt cables, Cologne, Germany

E2.3 HVDC cable rating methodology: Thermal, electrical and mechanical constraints

HUANG Ziyi, PILGRIM James A., LEWIN Paul L., SWINGLER Steve; University of Southampton, Southampton, UKTZEMIS Gregory; National Grid Plc, Warwick, UK

E2.4 Calculation of the current rating for complex cable arrangement in a deep tunnel

ANDERS George; Lodz University of Technology, Lodz, PolandBOCHENSKI Boguslaw; Kinectrics Inc., Toronto, Ontario, CanadaHENNING Gunnar; ABB AB, High Voltage Cables, Karlskrona, Sweden

E2.5 Accurate analytical formula for calculation of sheath and armour losses of three core submarine cables

HATLO Marius, OLSEN Espen, STOLAN Ronny; Nexans AS, Halden, NorwayKARLSTRAND Johan; JK Cablegrid Consulting AB, Karlskrona, Sweden

E2.6 Electrical contacts impact on the DC resistance measurement of metallic conductors: application on an industrial measurement device

ZEROUKHI Youcef, NAPIERALSKA-JUSZCZAK Ewa, MORGANTI Fabrice; Laboratory of Electro-technical Systems and Environment (LSEE), University of Artois, Béthune, FranceVEGA Guillaume; Nexans, Lens, FranceKOMEZA Krzysztof; Institute of Mechatronics and Information Systems Technical University of Lodz, Lodz, Poland

F2 Young researchers contest

Monday June 22nd, 2015 - 14:30 - 16:00 - Room: F

Chairman: GUBANSKI Stanislaw; Chalmers University of Technology, SwedenRapporteurs: NOTINGHER Petru; Institut d’Électronique du Sud - Université Montpellier 2,

CNRS, FranceTEYSSEDRE Gilbert; CNRS / Laplace, Université P. Sabatier, France

F2.01 The investigation of conduction current and dissipation power distributions in XLPE under HVDC at high temperature environment

FUJITOMI Toshiyuki, KATO Tsuyoshi, MIYAKE Hiroaki, TANAKA Yasuhiro; Tokyo City University, Tokyo, Japan

F2.02 Study of XLPE dielectric properties for HVDC cables during combined thermal and electrical ageing

HASCOAT Aurélien, CASTELLON Jérôme, AGNEL Serge; Institut d’Electronique du Sud, Université Montpellier 2, Montpellier, FranceFRELIN Wilfried, EGROT Philippe; EDF R&D, Les Renardières, FranceHONDAA Pierre, AMMI Soraya; RTE, Paris-La Défense, FranceLEROUX Dominique, ANDERSSON Johan, ERIKSSON Virginie; BOREALIS, Stenungsund, Sweden

F2.03 Infl uence factors of fi eld inversion in HVDC cables

FUCHS Karsten, BERGER Frank; Ilmenau University of Technology, Ilmenau, GermanyFISCHER Andreas, DRUMMER Dietmar; Institute of Polymer Technologie Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen-Nürnberg, Germany

F2.04 Analysis of technical planning principles for partial underground cabling in meshed extra-high voltage Grids

VEERASHEKAR Kishan; Friedrich Alexander University Erlangen-Nuremberg, Erlangen, GermanySIEBELS Carsten; TenneT TSO GmbH, Bayreuth, GermanyLA SETA Piergiovanni; Siemens AG, Erlangen, GermanyFUCHS Bernhard; RWTH Aachen University, Aachen, Germany

F2.05 Eco-friendly nanodielectrics with enhanced thermal and electrical properties for HVDC cable insulation

ZHOU Yao, HE Jinliang, HU Jun, DANG Bin; State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing, China

F2.06 Effect of state of stress on space charge accumulation in silicon rubber insulation of HVDC cables

GUO David; State Key Lab of Control and Simulation of Power Systems and Generation Equipment, Dept of Electrical Engineering, Tsinghua University, Beijing, China

F2.07 Spatially-resolved measurement and diagnostic method for power cables using interference characteristics of travelling waves

FISCHER Erik, WEINDL Christian; Institute of Electrical Energy Systems, University of Erlangen-Nuremberg, Erlangen, Germany

F2.08 Modeling of viscoelastic dynamic bending stiffness for VIV analysis of submarine cables

HEDLUND Johan; ABB AB, High Voltage Cables, Karlskrona, Sweden

F2.09 Effect of lightning impulses on a partially grown electrical tree

CORNISH Darryn R., NYMUPANGEDENGU Cuthbert; School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, South Africa

F2.10 Guide to EHV/HV cable sheath bonding application software

VALERO Alvaro; Technical University of Madrid (LCOE-F2I2), Madrid, Spain

F2.11 DC cable modeling and High Voltage Direct Current grid grounding system

LOUME Dieynaba, BERTINATO Alberto, NGUYEN TUAN Minh; SuperGrid Institute, Villeurbanne, FranceRAISON Bertrand; G2elab, Saint Martin d’Hères, France

F2.12 Development and engineering application of ±160 kV XLPE to three-terminal VSC HVDC project in China

HOU Shuai, FU Mingli, ZHAO Linjie; Electric Power Research Institute of China Southern Power Grid, Guangzhou, China

F2.13 Investigation of charge injection threshold fi eld on LDPE and XLPE materials

LIU Ning, CHEN George; University of Southampton, Southampton, UK

F2.14 Relationship between breakdown strengths and trapping parameters of serviced XLPE cables

LIU Ning, CHEN George; University of Southampton, Southampton, UKXU Yang; Xi’an Jiaotong University, Xi’an, China

F2.15 Effects of voltage magnitude on growth characteristics of electrical trees in silicone rubber

ZHANG Yunxiao, ZHOU Yuanxiang, SCHNETTLER Armin; State Key Lab of Control and Simulation of Power Systems and Generation Equipments, Department of Electrical Engineering, Tsinghua University, Beijing, ChinaZHANG Xu; North China Electric Power Research Institute Co Ltd, Beijing, China

F2.16 Optimization of High Voltage electrodes and HV cable accessories design by using MATLAB and FEMM

TUNA Enis; Demirer Kablo, Bilecik, Turkey

F2.17 Infl uence on measured conductor AC resistance of High Voltage cables when the shield is used as return conductor

HÖGÅS Marcus, RYDLER Karl-Erik; SP Technical Research Institute of Sweden, Borås, Sweden

F2.18 Measurement of the conductor temperature in power cable production

FRECHEN Henning, PUFFER Ralf, SCHNETTLER Armin; RWTH Aachen University, Aachen, GermanyBRAMMER Gregor; Forschungsgemeinschaft für Elektrische Anlagen und Stromwirtschaft e.V., Mannheim, Germany

F2.19 Improvement of ampacity ratings of Medium Voltage cables in protection pipes by comprehensive consideration and selective improvement of the heat transfer mechanisms within the pipe

BALZER Constantin, HINRICHSEN Volker; TU Darmstadt, High Voltage Laboratories, Darmstadt, GermanyDREFKE Christoph, STEGNER Johannes, SASS Ingo; TU Darmstadt, Geothermal Science and Technology, Darmstadt, GermanyHENTSCHEL Klaus; Bayernwerk / e-on, Regensburg, Germany

F2.20 Characterization of Transparent Fluorescent Silicones for Optical Monitoring of High-Voltage Cable Accessories

KUCHARCZYK Krzysztof, BANASZAK Szymon, GAWRYLCZYK Konstanty; West Pomeranian University of Technology, Szczecin, PolandLEISTNER André; Polymerics GmbH, Berlin, GermanySIEBLER Daniel; BAM Federal Institute of Materials Research and Testing, Berlin, GermanyHEIDMANN Gerd; IPH Institut “Prüffeld für Elektrische Hochleistungstechnik” GmbH (CESI Group), Berlin, Germany

F2.21 Predicted rating system for directly buried cables

HUANG Ru, PILGRIM James A., LEWIN Paul L.; University of Southampton, Southampton, UKSCOTT David, BLACKWELL Anna, MORRICE Daniel; National Grid plc, Warwick, UK

F2.22 Space charge behaviors of PP/EPDM/ZnO nanocomposites for recyclable HVDC cable

DANG Bin, HE Jinliang, HU Jun, ZHOU You; State Key Lab of Power Systems, Dept. of Electr. Eng., Tsinghua Univ., Beijing, China

F2.23 Estimating the losses in three core submarine power cables using 2D and 3D FEA simulations

STURM Sebastian, PAULUS Johannes; University of Applied Sciences Würzburg-Schweinfurt, Schweinfurt, GermanyBERGER Frank; Ilmenau University of Technology, Ilmenau, GermanyABKEN Karl-Ludwig; Norddeutsche Seekabelwerke GmbH /General Cable, Nordenham, Germany

F2.24 Thermal impedance of insulated overhead power cables heated by joule losses and solar radiation

CHATZIPANAGIOTOU Panagiotis, TOSCANO Alexandros Saverio, PAPAGIANNOPOULOS Ioannis; Aristotle University of Thessaloniki, Department of Electrical and Computer Engineers, Thessaloniki, GreeceDE MEY Gijbert; Ghent University, Department of Electronics and Information Systems, Ghent, BelgiumWIECEK Boguslaw; University of Lodz, Institute of Electronics Technical, Lodz, PolandMARANDA Witold, NAPIERALSKI Andrzej; Technical University of Lodz, Department of Microelectronics and Computer Science, Lodz, Poland

F2.25 Measurement and modeling of surface charge accumulation on insulators in HVDC gas insulated line (GIL)

ZHANG Boya, WANG Qiang, ZHANG Guixin; Tsinghua University, Beijing, China

Monday June 22nd, 2015 - 16:30

A3 HV operating conditions

Monday June 22nd, 2015 - 16:30 - 18:15 - Room: A

Chairman: SALDIVAR CANTU Candelario de J.; Viakable Operaciones, MexicoRapporteur: DUBOIS David; Nexans, France

A3.1 Indirect pipe water cooling study for a 220 kV underground XLPE cable system in New Zealand

JOYCE Richard; Transpower New Zealand Limited, Wellington, New ZealandLLOYD Simon, WILLIAMS Alan; Cable Consulting International, Sevenoaks, Kent, UK

A3.2 Cable replacement in a generation plant

JORAND Patrick, MOUSSET Fabrice, MAUGAIN Yves; EDF CIST, Saint-Denis, FranceOUENZAR Mehdi, GUYOT Hervé; SPAC, Clichy, France

A3.3 Degradation mechanism of SCOF cable due to cable core movement

MATSUYA Yuji, KAYA Takeshi, SOGA Manabu; The Kansai Electric Power Co., Inc., Osaka, JapanTSUTSUMI Takahiko, OKAMOTO Gaku; J-Power Systems Corporation, Osaka, JapanITABASHI Hideyuki, MITSUYAMA Yasuichi; VISCAS Corporation, Tokyo, Japan

A3.4 Performance evaluation of integrity monitoring based on optical fi bre distributed temperature and distributed acoustic sensing

CONWAY Chris; Bandweaver, Richmond, UKMONDANOS Michael; Silixa Ltd, Elstree, UK

A3.5 150 kV gas pressure cable systems in the Netherlands: experienced systems

SMIT Jacco, DE VRIES Frank, STEENIS Arie; Liandon B.V., Arnhem, The NetherlandsROSS Rob, SIBBALD Peter; TenneT, Arnhem, The Netherlands

A3.6 Operating records and recent technology of DTS system and dynamic rating system (DRS)

WATANABE Tsunefumi; J-Power systems Corporation, Osaka, Japan

A3.7 Application of knowledge engineering approach to mitigate the infant mortality risk of HV cable system in Mea Thailand

RAJAKROM Asawin; Metropolitan Electricity Authority, Bangkok, Thailand

B3 Submarine cable testing & qualifi cations

Monday June 22nd, 2015 - 16:30 - 18:15 - Room: B

Chairman: DE WILD Frank; DNV GL, The NetherlandsRapporteur: CHARLES Fabien; General Cable, France

B3.1 Long term qualifi cation of XLPE electrical insulation systems for offshore deep water cables

FAREMO Hallvard; SINTEF Energy Research, Trondheim, NorwayBENGTSSON Karl Magnus, KVARME Hans; Nexans Norway AS, Oslo, Norway

B3.2 Recommendations for mechanical tests on sub-marine cables

BOEDEC Marc, DUBOIS David; Nexans, Calais, FranceCLASEN Geir, STOLAN Ronny; Nexans, Halden, NorwayBRADLEY Caroline; National Grid Plc, Warwick, UKKRÜGER OLSEN Sören; Energinet, Ballerup, DenmarkKIM Sungyun; LS Cable & System, Gyeongbuk, Republic of KoreaMCPHAIL Allen; Cabletricity Connections Ltd., Vancouver, Washington, USAMIRAMONTI Gianni; Prysmian, Milan, ItalyKOUTI Tuomo; Prysmian, Kirkkonummi, FinlandJEROENSE Marc, TYRBERG Andreas; ABB, Karlskrona, SwedenNAKAJIMA Takenori; VISCAS Corporation, Tokyo, JapanPRIETO MONTERRUBIO Juan; Red Eléctrica de España, Madrid, SpainANTON Svetlana; nkt cables, Cologne, GermanyGEORGALLIS George; Hellenic Cables, Sousaki Korinthias, GreeceBOUDINET Nathalie, THEODULE Lucie; RTE, Paris La Défense, FranceISUS Daniel; General Cable, Manlleu, Catalunya, SpainGUIZZO Luca; TERNA, Rome, Italy

B3.3 Testing the allowable compressive limit of HVAC submarine cables

REDA Ahmed; Curtin University, Perth, Western Australia, Australia

B3.4 Type test and special tension test of 230 kV XLPE submarine cable system

ONA Satoshi, KAZAMA Tatsuya, NOZAKI Takehiro, MASHIO Shoji; J-Power Systems Corporation, Osaka, Japan

B3.5 Challenge of fault location on long submarine power cables

BAWART Manfred; BAUR Prüf und Messtechnik, Sulz, AustriaMARZINOTTO Massimo; TERNA, Rome, ItalyMAZZANTI Giovanni; University of Bologna, Bologna, Italy

B3.6 Extension of qualifi cation applied on a MV extruded submarine cable in France

MAMMERI Mohamed, MAURY Romain; General Cable, Montereau-Fault-Yonne, FranceDE ROBIEN Gabriel; EDF, Paris, FranceBELLOIR Vincent; ERDF, France

B3.7 Measurements of losses on three core submarine power cables

FRELIN Wilfried, MOREAU Christophe; EDF R&D, Moret-sur-Loing, FranceWILLEN Dag, THIDEMANN Carsten, WASCHK Volker; nkt cables, group gmbh & KG, GermanyDE ROBIEN Gabriel; EDF CIST, Saint-Denis, FranceBOUDINET Nathalie; RTE, Paris La Défense, France

C3 Diagnosis methods

Monday June 22nd, 2015 - 16:30 - 18:15 - Room: C

Chairman: BOONE Willem; DNV GL, The NetherlandsRapporteur: NAUD Antoine; RTE, France

C3.1 Localized temperature sensing (LTS) as new approach to HV cable system monitoring and uprating

BALZA Xabier; General Cable, Barcelona, SpainBENGOECHEA Javier; Lumiker, Bilbao, SpainGONZÁLEZ Alberto, MARTÍN-DORADO Ángel; Unión Fenosa Distribución, Madrid, Spain

C3.2 Fiber optic temperature sensor using intermodal interference for linear infrastructures monitoring

MUSIN Frédéric, MEGRET Patrice, WUILPART Marc; University of Mons - FPMs - SET, Mons, BelgiumGRANDJEAN Henri; ORES, Louvain-la-Neuve, BelgiumCALLEMEYN Jan, FOHAL Jean-Christophe; CERISIC, Mons, Belgium

C3.4 Long power cables: exposing incipient faults and optimizing performance using extra-long distance fi ber optic distributed temperature monitoring

ROCHAT Etienne, NIKLÈS Marc, MATVICHUK Baz, ROWSELL Jane; Omnisens SA, Morges, Switzerland

C3.5 Estimating the impact of VLF frequency on effectiveness of VLF withstand diagnostics

HAMPTON Nigel, PERKEL Josh; NEETRAC, Atlanta, Georgia, USAHERNANDEZ Jean Carlos; Universidad de Los Andes, Merida, VenezuelaTOMER Vivek, KUNTSEVICH Marina; Dow Chemical, Spring House, USA

C3.6 Off-line diagnostic measurements: Type of measurement versus insulation weakness targeted

ESPILIT Thierry; EDF R&D, Ecuelles, FranceDRAPEAU Jean-François; IREQ, Varennes, Québec, CanadaHVIDSTEN Sverre; SINTEF Energy Research, Trondheim, NorwayTAMBRUN Roger; ERDF, Paris La Défense, France

C3.7 Online PD monitoring of short cable systems installed in sub-stations

GARNACHO Fernando; LCOE-FFII, Madrid, SpainORTEGO Javier, SÁNCHEZ-URÁN Miguel Ángel; ETSIDI-UPM, Madrid, SpainGONZÁLEZ Alberto; UFD-Gas Natural Fenosa, Madrid, Spain

D3 Thermo-mechanical testing

Monday June 22nd, 2015 - 16:30 - 18:30 - Room: D

Chairman: MARELLI Marco; Prysmian Group, ItalyRapporteur: DHUICQ Bernard; General Cable, France

D3.1 North Auckland and Northland 220 kV cable project - managing thermo-mechanical forces in large conductor XLPE cable circuits

JOYCE Richard, MCBURNEY Ian, GREGROY Brian; Transpower New Zealand Limited, Wellington, New Zealand

D3.2 Cigre WG B1.34: mechanical forces with large conductor cross section XLPE cables

KAUMANNS Johannes; LS Cable & System, Gumi-si, Republic of KoreaBACCHINI Marco; Prysmian, Milan, ItalyGEHLIN Gunnar; Svenska Kraftnaet, Stockkolm, SwedenGREGORY Brian; Cable Consulting International, Sevenoaks, Kent, UKJOHNSON Dennis; Powereng., Lenexa, USAKURATA Tatsuo; J-Power systems Corporation, Osaka, JapanMAY Hans-Peter; nkt cables, Cologne, GermanyPYE Caroline; Mott McDonald, Brighton, IrelandREINOSO Ricardo; Red Eléctrica de España, Madrid, SpainSAMUEL Jourice; Nexans, Calais, FranceTARNOWSKI Janislaw; IREQ, Varennes, Québec, CanadaVAN DEN THILLART Ron; Tennet, Tilburg, The NetherlandsVILHELMSEN Morten; Energinet.dk, Frederica, DenmarkWALD Detlef; Eifelkabel, Villmergen, Switzerland

D3.3 Thermo-mechanical analysis of MV underground long links

TANZEGHTI Houssam, BRULENT Yves; EDF R&D, Ecuelles, FranceTAMBRUN Roger; ERDF, Paris, France

D3.4 Thermo-mechanical behavior of HV and EHV large conductor XLPE cables in duct-manhole systems

ECKROAD Steve, ZHAO Tiebin; EPRI, Palo Alto, California, USAGALLOWAY Stephen J., GREGORY Brian; Cable Consulting International, Sevenoaks, Kent, UKKING Stephen M.; Dassault Systemes UK Ltd, Warrington, Cheshire, UK

D3.5 Measurement of thermomechanical properties of 400 kV 2500 mm2 cable

PILGRIM James A., HUNTER Jack, PALMER Neil; University of Southampton, Southampton, UKGREGORY Brian; Cable Consulting International, Sevenoaks, Kent, UKMOORHOUSE David; National Grid plc, Warwick, UK

D3.6 Evaluation on thermo-mechanical characteristics of outdoor termination by full scale real test in underground power cable systems

JUNG Chae-kyun, PARK Hung-sok, KANG Ji-won; KEPCO Research Institute, Daejeon, Republic of KoreaROH Tae-hyueng, KIM Jae-seung; KEPCO Head Offi ce, Seoul, Republic of Korea

D3.7 220 kV transpower NZ North Auckland and Northland (NAaN) project - design validation of thermo-mechanical behaviour

ROUILLARD Vincent; Victoria University, Melbourne, Victoria, AustraliaRAHMAN Naveed; Nexans Olex, Tottenham, Victoria, Australia

D3.8 Cable installation in vertical shaft

MAGNANI Francesco; Prysmian Power Link S.r.l, Milan, ItalyBACCHINI Marco; Cable Installation Consultant, Italy

E3 Cable ratings calculations 2

Monday June 22nd, 2015 - 16:30 - 18:30 - Room: E

Chairman: COLLA Luigi; Prysmian Power Link Srl, ItalyRapporteur: DORISON Eric; EDF R&D, France

E3.1 A new approach for estimation of the dynamic thermal rating model parameters

FARAHANI Alireza, KAMARA Wouleye; CYME Int/Eaton Corp., Montréal, Québec, CanadaANDERS George; Lodz University of Technology, Lodz, PolandBIC Emmanuel; General Cable, Montereau-Fault-Yonne, FranceKEPPLER Uwe; AP Sensing, Boeblingen, Germany

E3.2 Results and verifi cations from REE experience on monitoring isolated cables with DTS

ALVAREZ-CORDERO Gabriel, SOTO-CANO Lourdes, GONZALEZ-MORALES Gerardo; Red Eléctrica de España, Alcobendas, Madrid, Spain

E3.3 New issues in current rating of power cables installed in unventilated tunnels

DORISON Eric, FRELIN Wilfried; EDF R&D, Moret-sur-Loing, FranceANDERS George; Lodz University of Technology, Lodz, PolandMOREAU Olivier; EDF CIST, Dubai, United Arab Emirates

E3.4 Refi nement in ambient temperature selection for current rating calculations

LESUR Frédéric, LEJOUR Victor; RTE, Paris, France

E3.5 Derating factors for multiple circuits of low and medium voltage cable installations

BOCHENSKI Boguslaw; Kinectrics Inc., Toronto, Ontario, CanadaANDERS George; Lodz University of Technology, Lodz, Poland

E3.6 A novel cooling solution for an intersection of a 2x2 duct bank with HV cables crossed by a steam pipe

ANDERS George; Lodz University of Technology, Lodz, PolandBRAKELMANN Heiner; BCC Cable Consulting, Duisburg, GermanyCHERUKUPALLI Sudhakar; BC Hydro, Vancouver, Canada

E3.7 Snaking of cables in empty pipes

MAIOLI Paolo; Prysmian SpA, Milan, ItalyBACCHINI Marco; Prysmian Power Link Srl, Milan, Italy

E3.8 Review of underground cable impedance and admittance formulas

AMETANI Akihiro, LAFAIA Isabel, MAHSEREDJIAN Jean; Polytechnique Montreal, Montréal, Québec, CanadaNAUD Antoine; Reseau de Transport d’Electricite, Paris, France

Tuesday June 23rd, 2015 - 09:00

A4 HV AC new developments

Tuesday June 23rd, 2015 - 09:00 - 10:30 - Room: A

Chairman: WANG Ying; Prysmian Group, ItalyRapporteur: JOUBERT Vincent; General Cable (Silec Cable), France

A4.1 The degassing process of HV XLPE cables and its infl uence on selected electrical properties

HUOTARI Pekka; Maillefer Extrusion Oy, Vantaa, FinlandBENGTSSON Magnus; Nexans Norway AS, Halden, NorwayBOSTRÖM Jan-Ove, SMEDBERG Annika; Borealis AB, Stenungsund, Sweden

A4.2 Development of a up to 400 kV XLPE cable with low-smoke properties to be installed in a tunnel

WALD Detlef; Eifelkabel, Villmergen, SwitzerlandATAY Feyzullah, CIHAN Ismet; Demirer Kablo, Istanbul, TurkeyWILLIAMS Paul; UK Power Networks, Crawley, UK

A4.3 Development of compact designed 66/77 kV class XLPE cable system

MARUICHI Shinji; VISCAS Corporation, Ichihara, Chiba, JapanOONO Koichi, MOKI Masaya, NIINOBE Hiroshi; VISCAS Corporation, Shinagawa-Ku, Tokyo, Japan

A4.4 Development of 500 kV XLPE cable accessories

LI Guoji, TAKAHASHI Kenji; SWCC Showa Cable Systems Co Ltd, Sagamihara-city, Kanagawa-pref, JapanSUMIMOTO Tsutomu; SHOWA-TBEA (Shandong) CABLE ACCESSORIES CO., LTD., Xintai City, Shandong Province, ChinaLIU Zhaojian; TBEA Shandong Luneng Taishan Cable Co., Ltd., Xintai City, Shandong Province, ChinaKUWAKI Akihisa; EXSYM CORPORATION, Sagamihara City, Kanagawa Province, Japan

A4.5 Improved design for anti-scattering in fault condition of outdoor termination

JUN Myunghun, KIM Youngbum, CHOI Soogeol, KIM Jinwoo; ILJIN Electric, Seoul, Republic of Korea

A4.6 Compact paperless joint for transition from LPFF to XLPE cables

CORSARO Pietro; Brugg Kabel AG, Brugg, Aargau, Switzerland

B4 Installations of submarine lines

Tuesday June 23rd, 2015 - 09:00 - 10:30 - Room: B

Chairman: ZHANG Dongping; TenneT TSO GmbH, GermanyRapporteur: CHARVET Jean; RTE, France

B4.1 New approach to installation of offshore wind energy cables

GRIFFIOEN Willem, GUTBERLET Christophe; Plumettaz SA, Bex, SwitzerlandMULDER-GROOTOONK Jeannette; Wavin T&I, Dedemsvaart, The NetherlandsHOJSGAARD Lars; nkt Cables AS, Broendby, DenmarkGRATHWOHL Willy; nkt Cables AS, Asnaes, DenmarkBRINGSELL Håkan; nkt Cables AB, Falun, SwedenSOERENSEN Johnny, BORCH-JENSEN Niels-Joergen; Siemens Windpower, Brande, Denmark

B4.2 Lillebælt - Installation and commissioning of world’s fi rst 400 kV 3-cores submarine cable

AHRENKIEL VILHELMSEN Morten; Energinet.dk, Fredericia, DenmarkKROGH Flemming; ABB HVC, Karlskrona, Sweden

B4.3 Dynamic cable installation for Fukushima fl oating offshore wind farm demonstration project

YAGIHASHI Kiyotomo, TATENO Yuji; VISCAS Corporation, Shinagawa-Ku, Tokyo, JapanMANABE Hiroki, SAKAKIBARA Hiroyuki; Furukawa Electric CO., Ltd., Chiyoda, Tokyo, Japan

B4.4 Development of a three-terminal ready HVDC interconnector between France and Great Britain via the island Alderney: the FAB Project

WAERAAS DE SAINT MARTIN Gro, CHARVET Jean; RTE, Paris, FranceKELLY Sean; Transmission Investment, London, UK

B4.6 Zanzibar interconnector 132 kV submarine cable in Tanzania

NAKAMURA Yoshiharu, OTA Masanori; VISCAS Corporation, Tokyo, JapanDONAGHY Robert; ESB International, Dublin, Ireland

C4 MV cable diagnosis

Tuesday June 23rd, 2015 - 09:00 - 10:30 - Room: C

Chairman: SMITH III John T.; General Cable Corporation, USA (to be confi rmed)Rapporteur: TOURAINE Jean-Charles; Prysmian Câbles & Systèmes, France

C4.1 On line diagnosis experimentations for MV cables in ERDF distribution network

DIGARD Hervé; EDF R&D, Moret-sur-Loing, FranceTAMBRUN Roger; ERDF, Paris La Défense, France

C4.2 Accurate on-line fault location (full breakdowns) for MV cables with Smart Cable Guard

STEENNIS Fred; DNV GL, Arnhem, The NetherlandsVAN HUIJKELOM Martijn; Enexis, Arnhem, The NetherlandsVAN MINNEN Frank; Alliander, Arnhem, The NetherlandsBLEEKER Pascal; Locamation, Enschede, The Netherlands

C4.3 On-site condition assessment of XLPE MV cable joints by using an insulation tester

BENJAMINSEN Jan Tore, ENOKSEN Henrik, HVIDSTEN Sverre; SINTEF Energy Research, Trondheim, Norway

C4.4 Combined application of diagnostics tools for MV underground cables

NEIER Tobias; BAUR Prüf und Messtechnik, Sulz, Austria

C4.5 Best practice guideline for the complete condition monitoring (cm) of offshore wind farm (OWF) cable networks

GIUSSANI Riccardo, SELTZER-GRANT Malcolm, RENFORTH Lee; HVPD Ltd, Manchester, UK

C4.6 Challenges associated with diagnostic selection for condition assessment of long MV underground feeder circuits

DRAPEAU Jean-François, BERNIER Simon, JEAN Daniel; Hydro-Québec (IREQ), Varennes, Québec, Canada

D4 On-site and laboratory tests 1

Tuesday June 23rd, 2015 - 09:00 - 10:30 - Room: D

Chairman: PLATH Ronald; Technische Universität Berlin, GermanyRapporteur: MOREAU Christophe; EDF R&D, France

D4.1 Investigation of electrical and morphological properties of 10 kV XLPE cable insulation specimens

SHUVALOV Mikhail, OVSIENKO Vladimir; JSC “VNIIKP”, Moscow, RussiaLAHTI Mikko, HUOTARI Pekka; Maillefer Extrusion Oy, Vantaa, Finland

D4.2 Condition of shielded 5 kV pink EPR insulated cables after 25 years of service in wet environment

FRYSZCZYN Bogdan; Cable Technology Laboratories, Inc., New Brunswick, New Jersey, USAMANTEY Andrew; EPRI, Charlotte, NC, USA

D4.3 Measures to reduce skin-effect losses in power cables with optimized conductor design and their evaluation by measurement

PLATH Ronald, SCHUHMANN Rolf, SUCHANTKE René; Technical University Berlin, Berlin, GermanyWASCHK Volker; nkt cables, Cologne, GermanySCHROEDER Gero; Südkabel GmbH, Mannheim, Baden Württemberg, Germany

D4.4 AC resistance measurements on skin-effect reduced large conductor power cables with standard equipment

SCHROEDER Gero, HAERING Dominik, WEINLEIN Andreas, BOSSMANN Axel; Südkabel GmbH, Mannheim, Baden Württemberg, GermanyPLATH Ronald; Ing.-Büro HPS Berlin, Berlin, GermanyVALTIN Markus; Electronics - Web and More GbR, Berlin, GermanyMAJID Maitham; Balfour Beatty Utility Solutions, Dartford, UK

D4.5 DC conductivity characterization of cables and correlation with lab measurements

CHARRIER Dimitri; Nexans Research Center, Lyon, France

D4.6 Hyperbaric chamber to test robustness of electric cables

FRÉANI Laurent; Tech-Plus, Bandol, FranceLE PÉCHON Jean-Claude; JCLP Hyperbarie, Paris, France

E4 Modelling

Tuesday June 23rd, 2015 - 09:00 - 10:30 - Room: E

Chairman: HAMPTON Nigel; Georgia Tech NEETRAC, USARapporteur: NGUYEN TUAN Minh; EDF R&D, France

E4.1 Use of conformal transform for current rating calculations of underground cable systems

LESUR Frédéric; RTE, Paris, France

E4.2 Effi ciency of cable transposition to decrease the induced voltage on linear third-party installations

LYS Benoit, CABAU Matthieu, LESUR Frédéric; RTE, Paris, France

E4.3 Evaluation of “cross-talk” in power cables by use of 3d fi nite element computations

HOYER-HANSEN Martin, SOLHEIM Kristian Thinn, LERVIK Jens Kristian; SINTEF Energy Research, Trondheim, Norway

E4.4 Wide-frequency modelling of submarine cables for deep water DC power delivery

CARVALHO Karolina, SOUZA Luiz Felipe, RABELO Balduino, LIMA Luiz André; GE Global Research Center - Brazil Technology Center, Rio de Janeiro, RJ, Brazil

E4.5 Infl uence of the screen/armour permeability in magnetic fi elds generated by HV cables

FARIA DA SILVA Filipe, LETH BAK Claus; Aalborg University, Aalborg, DenmarkEBDRUP Thomas; Energinet.dk, Fredericia, Denmark

E4.6 Boutre-Trans project: 225 kV AC underground cable installed in the South-East of France

LAFAIA Isabel, AMETANI Akihiro, MAHSEREDJIAN Jean; Polytechnique Montreal, Montréal, Québec, CanadaNAUD Antoine; Reseau de Transport d’Electricite, Paris, FranceCORREIA DE BARROS Maria Teresa; University of Lisbon, Lisbon, Portugal

Tuesday June 23rd, 2015 - 11:00

A5 HV cable integration in network

Tuesday June 23rd, 2015 - 11:00 - 12:30 - Room: A

Chairman: BARBER Kenneth; NAN Electric Cable, AustraliaRapporteur: ALLAIS Arnaud; Nexans Research Center, France

A5.1 Reliability of cable based transmission grids operated based on temperature limits

OLSEN Rasmus; Energinet.dk, Fredericia, DenmarkHOLBOELL Joachim; Technical University of Denmark, Kgs. Lyngby, DenmarkGUDMUNDSDOTTIR Unnur Stella; Dong Energy, Fredericia, Denmark

A5.2 Installation of cables system connections to gas insulated metal-enclosed switchgear (GIS)

MIREBEAU Pierre; Nexans, Calais, FranceMICHON Franck, MANSOUR Jawdat, SANTANA José; Prysmian Group, Gron, FranceMAMMERI Mohamed, DHUICQ Bernard; General Cable, Montereau-Fault-Yonne, FranceBAIL Roland; SYCABEL, Paris, FranceGUILLEMIN Martial; RTE, Paris, FranceTAILHADES Philippe; GIMELEC, Paris, FranceLECLERC Frédéric; SIEMENS, Grenoble, FranceFICHEUX Arnaud; Alstom, Aix-les-Bains, France

A5.3 Study on overvoltage of 500 kV cable-overhead mixed lines

YAN Biao, CHEN Li, CHEN Jie, TAO Fengbo, WANG Jingjun; Jiangsu Electric Power Company Research Institute, Nanjing, China

A5.4 French feedback on civil and installation works of transmission underground cable systems

GUYOT Hervé; SERCE, Paris, FranceHASCOET Serge, LESUR Frédéric; RTE, Paris, France

A5.5 Transient studies of power cable sections in 380 kV transmission system

MACKOW Andrzej, KIZILCAY Mustafa; University Siegen, Siegen, North Rhine-Westphalia, Germany

A5.6 Installation of twenty-four (24) lines of 150 kV XLPE power cables at 2.5 m depth below ground level in the tropical urban city Jakarta

STEVEN John Yuddy; PLN Indonesia, Jakarta, IndonesiaSINISUKA Ngapuli; Institut Teknologi Bandung, Bandung, Indonesia

B5 Submarine cables - GeneralTuesday June 23rd, 2015 - 11:00 - 12:30 - Room: B

Chairman: CAMPBELL Steven; Superior Essex Energy, USARapporteur: DOMENECH Sabina; General Cable, France

B5.1 Analysis of electric fi eld distribution in XLPE insulation of DC submarine cable

FAN Yadong, WANG Jianguo, HONG Zejun, ZHOU Mi, CAI Li, LI Xianqiang; Wuhan University, Wuhan, China

B5.2 Development of submarine MV-AC power cable with aluminum conductor

MUELLER-SCHUETZE Sven, OTTERSBERG Heiner, SUHR Carsten, KRUSCHE Ingo; Norddeutsche Seekabelwerke GmbH / General Cable, Nordenham, Lower Saxony, GermanyISUS FEU Daniel; General Cable, Manlleu, Barcelona, Spain

B5.3 Impact of HVDC cable confi guration on compass deviation

MEIJER Sander, DE GRAAF Roald; DNV GL, Arnhem, The NetherlandsHEMPHILL Stephen, MCGUCKIN Mick; Mutual Energy, Belfast, Ireland

B5.4 Thermal rating method of j tubes using fi nite element analysis techniques

CHIPPENDALE Richard, CANGY Priank, PILGRIM James A.; University of Southampton, Southampton, UK

B5.5 Degradation rates in high voltage subsea cables with polymeric water barrier designs

ANDERSEN VE Torbjørn, HVIDSTEN Sverre, HØLTO Jorunn; SINTEF Energy Research, Trondheim, NorwayFURUHEIM Knut-Magne, HEDSTRÖM Hanna; Nexans Norway AS, Halden, Norway

B5.6 EPR insulated cables for modern offshore systems

COLLA Luigi, ZACCONE Ernesto; Prysmian Power Link Srl, Milan, ItalyREIG Aida; Prysmian Powerlink, Drammen, Norway

C5 HV and EHV cable diagnosis

Tuesday June 23rd, 2015 - 11:00 - 12:30 - Room: C

Chairman: TANAKA Hideo; VISCAS Corporation - Power Cable Division, Tokyo, JapanRapporteur: BIC Emmanuel; General Cable, France

C5.1 Permanent PD monitoring experience on shanghai 500 kV power cable lines

JIANG Jun, GAO Xiaoqing, QIAN Tianyu; Shanghai Electric Power Company, Shanghai, ChinaXIAO Chuanqiang, DAI Hongbin; SINDIA, Beijing, China

C5.2 Effective on-site testing and non-destructive diagnosis of new installed and service aged HV (EHV) power cables up to 230 kV

GULSKI Edward, JONGEN Rogier; onsite hv solutions ag, Luzern, SwitzerlandPARCIAK Jaroslaw; onsite hv solutions Central Europe Sp. Z o.o., Warsaw, PolandMINASSIAN Rafael; onsite hv solutions Americas Inc., Toronto, Ontario, CanadaRAKOWSKA Aleksandra, SIODLA Krzysztof; Poznan University of Technology, Poznan, Poland

C5.3 Short-term partial discharge monitoring as a diagnostic tool on 400 kV XLPE cable

HABEL Markus; IPH GmbH Berlin, Berlin, Germany

C5.4 Condition monitoring of electrical cables using line resonance analysis (LIRA)

FANTONI Paolo; Wirescan AS, Vinterbro, Norway

C5.5 An alternative approach about fault location on HVAC and HVDC cables during commissioning and operation

BÖHME Frank, SCHIERIG Stefan, HENSEL Michael; HIGHVOLT Prüftechnik Dresden GmbH, Dresden, Saxony, Germany

C5.6 Laboratory testing of 33 kV and 132 kV subsea cables with insulation defects

SELTZER-GRANT Malcolm, GIUSSANI Riccardo, RENFORTH Lee; HVPD Ltd, Manchester, UK

D5 On-site and laboratory tests 2

Tuesday June 23rd, 2015 - 11:00 - 12:30 - Room: D

Chairman: HENNUY Blandine; Laborelec, BelgiumRapporteur: SANTANA José; Prysmian Câbles & Systèmes, France

D5.1 Robust characterization of the DC-conductivity of HVDC insulation materials at high electric fi elds

GHORBANI Hossein; ABB AB, High Voltage Cables, Karlskrona, SwedenOLSSON Carl-Olof; ABB AB, Corporate Research, Västerås, SwedenANDERSSON Carl-Johan, ENGLUND Villgot; Borealis AB, Stenungsund, Sweden

D5.2 The impact of water fi lling of cable conductors during accelerated water tree ageing tests

HVIDSTEN Sverre, FAREMO Hallvard, HELLESOE Svein Magne; SINTEF Energy Research, Trondheim, Norway

D5.3 Automated temperature monitoring and control system for type and design testing of high voltage XLPE insulated cable systems

BOEV Ivan, BOBKO Rick, LI Ziqin; Kinectrics Inc., Toronto, Ontario, Canada

D5.4 Progress in optical PD detection for translucent and transparent HV cable accessories with improved fl uorescent optical fi bers

PLATH Ronald; Technical University Berlin, Berlin, GermanyHABEL Wolfgang, SIEBLER Daniel, ROHWETTER Phillip, LOTHONKAM Chayiaporn; BAM Berlin, Berlin, GermanyHEIDMANN Gerd, VATERRODT Klaus; IPH GmbH Berlin, Berlin, GermanyLEISTNER Aniela, LEISTNER André; Polymerics, Berlin, GermanyPEPPER Daniel; Beuth Hochschule, Berlin, Germany

D5.5 Optical PD detection in high voltage cable accessories

EIGNER Alexander, KRANZ Thomas; Tyco Electronics Raychem GmbH, Ottobrunn, GermanyVATERRODT Klaus, HEIDMANN Gerd; IPH GmbH Berlin, Berlin, Germany

D5.6 Online partial discharge testing of power cables in high noise environment

KHAN Ammar Anwar; Qualitrol, Glasgow, UK

E5 Cable and accessories - Design, applications

Tuesday June 23rd, 2015 - 11:00 - 12:30 - Room: E

Chairman: KVARTS Thomas; DONG Energy, DenmarkRapporteur: DORY Matthieu; RTE, France

E5.1 Infl uence of heat-shrink joints and terminations on tan delta values of a medium voltage cable installation at very low frequency

JOUBERT Theresa; Vaal University of Technology, Vanderbiljpark, South AfricaWALKER Jerry; Walmet Technologies, Vereeniging, South Africa

E5.2 AC resistance of submarine cables

MAIOLI Paolo, BECHIS Massimo; Prysmian SpA, Milan, ItalyDELL’ANNA Gaia; Prysmian Power Link Srl, Milan, Italy

E5.3 Study of the behaviour of a n-metal cable screen subject to an adiabatic short-circuit

DOMINGO CAPELLA José María; Grupo General Cable Sistemas SL, Barcelona, Spain

E5.4 Evaluation of how semiconducting versus insulation sealing materials infl uences high voltage cables production and testing

HUUVA Ramona, HATLO Marius; Nexans Norway AS, Halden, Norway

E5.5 XLPE cables with aluminium laminated sheath

ROENNINGEN Terje, SIVERTSVOLL Børre Johansen; Siemens AS, Trondheim, NorwayFAREMO Hallvard, BRUASET Are, PEDERSEN Atle, LERVIK Jens Kristian; SINTEF Energy Research, Trondheim, Norway

E5.6 Frequency dependency of single-core cable parameters

BREMNES Jarle J.; Unitech Power Systems AS, Oslo, NorwayEVENSET Gunnar; Power Cable Consulting AS, Halden, Norway

Tuesday June 23rd, 2015 - 14:30

A6 HVDC cables & systems

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: A

Chairman: SWINGLER Steve; University of Southampton, UKRapporteur: SAMUEL Jorice; Nexans, France

A6.1 Development and engineering application of ±160 kV XLPE to three-terminal VSC HVDC project in China

HOU Shuai, FU Mingli, ZHAO Linjie; Electric Power Research Institute of China Southern Power Grid, Guangzhou, Guangdong, China

A6.2 Rating of HVDC submarine cable crossings

HUANG Ziyi, PILGRIM James A., LEWIN Paul L., SWINGLER Steve; University of Southampton, Southampton, UKTZEMIS Gregory; National Grid Plc, Warwick, UK

A6.3 Experience and challenge of cable connections of offshore wind farms in German North Sea

WERLE Volker, ZHANG Dongping, JUNG Jochen; TenneT TSO GmbH, Bayreuth, Germany

A6.4 345 kV DC XLPE extruded cable systems development

MAMMERI Mohamed, PAUPARDIN Marie-Laure, LECOURTIER Nathalie; General Cable, Montereau-Fault-Yonne, France

A6.5 Review of HVDC insulated transmission cables technologies

MIREBEAU Pierre; Nexans, Paris, FranceFROHNE Christian; Nexans, Hannover, GermanyLARSEN Vegar Syrtveit; Nexans, Oslo, Norway

A6.6 Development process of extruded HVDC cable systems

HAERING Dominik, SCHROEDER Gero, WEINLEIN Andreas, BOSSMANN Axel; Südkabel GmbH, Mannheim, Baden Württemberg, Germany

B6 Materials for HVDC cables

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: B

Chairman: GUBANSKI Stanislaw; Chalmers University of Technology, SwedenRapporteur: TEYSSEDRE Gilbert; CNRS / Laplace, University P. Sabatier, France

B6.1 Study of the thermal ageing of the XLPE for HVDC applications

BILLORE Justine, AUGE Jean-Louis, JOUBERT Charles; Ampere Laboratory, Villeurbanne, FrancePRUVOST Sébastien, GAIN Olivier; IMP Laboratory, Villeurbanne, FranceALLAIS Arnaud, DARQUES Michaël; SuperGrid Institute, Villeurbanne, France

B6.2 Long term performance of XLPE insulation materials for HVDC cables

ERIKSSON Virginie, ANDERSSON Johan, ENGLUND Villgot, HAGSTRAND Per-Ola, KONTRO Anna, NILSSON Ulf H., SILFVERBERG Emy, SMEDBERG Annika; Borealis AB, Stenungsund, Sweden

B6.3 Key properties of next generation XLPE insulation material for HVDC cables

ENGLUND Villgot, ANDERSSON Johan, ERIKSSON Virginie, HAGSTRAND Per-Ola, LOYENS Wendy, NILSSON Ulf H., SMEDBERG Annika; Borealis AB, Stenungsund, Sweden

B6.4 Effect of static mechanical strain on the DC conductivity of extruded cross-linked polyethylene cable insulation

HESTAD Øystein L., ENOKSEN Henrik, HVIDSTEN Sverre; SINTEF Energy Research, Trondheim, Norway

B6.5 DC electrical conductivity in LDPE-based nanocomposites

HOANG Anh, GUBANSKI Stanislaw, SERDYUK Yuriy; Chalmers University of Technology, Gothenburg, SwedenPALLON Love, LIU Dongming, COBO SANCHEZ Carmen, GEDDE Ulf; KTH Royal Institute of Technology, Stockholm, Sweden

B6.6 Loss of dielectric strength of polymers due to high-frequency voltages in HVDC applications

BIRLE Matthias, LEU Carsten; Technische Universität Ilmenau, Research Unit High-Voltage Technologies, Ilmenau, Germany

C6 Maintenance

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: C

Chairman: AWAD Ray; Ray Awad Inc., CanadaRapporteur: GALERON Didier; Nexans, France

C6.1 Hydro-Québec advancements with infrared imaging for the maintenance of the underground medium voltage cable system

TRÉPANIER Michel, CÔTÉ Jacques; Hydro-Québec, Montréal, Québec, Canada

C6.2 REE’s research and development projects related to predictive maintenance based on monitoring of critical parameters in high voltage underground cables

DONOSO Gonzalo, REINOSO Ricardo, GARCÍA Rafael, ALVARADO Luis Felipe; Red Eléctrica de España, Madrid, SpainORTEGO Javier; DIAEL, Madrid, SpainTESTA Luigi; Prysmian Cables and Systems, Barcelona, Spain

C6.3 Rejuvenation of EPR-insulated medium voltage underground cables

VARJIAN Richard, BUSBY David, BERTINI Glen; Novinium, Inc, Auburn, Washington, USA

C6.4 DGA (dissolved gas analysis) diagnostic method reveals internal carbonization in oil-fi lled High Voltage extruded cable terminations

SINGH Nirmal, SINGH Sandeep, REYES Rommy; DTE Energy, Detroit, MI, USAHLAVAC Jeff, SCHMIDT Robert; Lincoln Electric System, Lincoln, Nebraska, USAUZELAC Milan; G&W Electric Company, Bolingbrook, IL, USAZHAO Tiebin, KUMMER David; EPRI, Charlotte, NC, USA

C6.5 Prelocating and pinpointing faults on underground Medium-Voltage cables: review of Hydro-Quebec’s experience

REYNAUD Lionel, PINEAU Daniel; Hydro-Québec (IREQ), Varennes, Québec, CanadaCÔTÉ Jacques; Hydro-Québec, Montréal, Québec, Canada

C6.6 Dielectric diagnosis of extruded cable insulation by very low frequency and spectroscopy techniques - a few case studies

BURJUPATI Nageshwar Rao; Central Power Research Institute, Bangalore, Karnataka, India

D6 Specifi c testing trends 1

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: D

Chairman: ZHAO Tiebin (Tom); EPRI - Electrical Power Research Institute, USARapporteur: FAVRIE Chantal, France

D6.1 Experiences of combined HV & EHV qualifi cations to IEC, AEIC and challenges IEEE 48 & 404

RILEY Caryn, PERKEL Josh, HILL Ray, HAMPTON Nigel; NEETRAC, Atlanta, Georgia, USA

D6.2 How to perform a pre-qualifi cation test - interpretation of the standard

PULTRUM Edwin, SLOOT Wouter, EILANDER Cor, BAAS Alphons, BIN Gu; KEMA Laboratories, Arnhem, The Netherlands

D6.3 Effectiveness of tests after installation on power cable systems

VAN DER WIELEN Peter, VAN MAANEN Bernd, STEENNIS Fred; DNV GL, Arnhem, The Netherlands

D6.4 Final countdown for CPR cable classifi cation - View from a notifi ed body

CORNELISSEN Christian; VDE Testing and Certifi cation Institute, Offenbach, Germany

D6.5 Testing submarine cables for combined axial compression and bending loads

TYRBERG Andreas, ERIKSSON Erik; ABB AB, High Voltage Cables, Karlskrona, SwedenGRØNSUND Jørgen, KLÆBO Frank; MARINTEK, Department of Structural Engineering, Trondheim, Norway

D6.6 Weibull analysis as a tool to describe DC breakdown performance and distribution in polyethylene for HVDC at laboratory scale

CHARRIER Dimitri, GUFFOND Raphael, MAZEL Christelle, MERLE Daphne, ALLAIS Arnaud; Nexans Research Center, Lyon, France

E6 Technical challenges

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: E

Chairman: KOO Ja-yoon; Hanyang University, Republic of KoreaRapporteur: TARDY Kevin; RTE, France

E6.1 Progress control in the context of the project management for the execution of a 320 kV HVDC land cable project - Dolwin 2

EBERT Sebastian, BORN Johann; ABB AG, Mannheim, Baden Württemberg, Germany

E6.2 Integration of an 88 km 220 kV AC cable into the Victorian electricity network in Australia

MCMILLAN Lee, JANJIC Miron; Beca Pty Ltd, Melbourne, Victoria, AustraliaCHRISTMAS Ian; Beca Pty Ltd, Brisbane, Australia

E6.3 HVDC & HVAC cable systems delivered on long length drums

SANTANA José, MICHON Franck, MANSOUR Jawdat; Prysmian Group, Gron, FranceMIREBEAU Pierre, ADAM Dominique; Nexans, Calais, FranceMAMMERI Mohamed, DHUICQ Bernard; General Cable, Montereau-Fault-Yonne, FranceBAIL Roland; SYCABEL, Paris, FranceLESUR Frédéric; RTE, Paris, France

E6.4 Cable quality assurance of offshore projects in the German North Sea

ZHANG Roland Dongping, WERLE Volker, JUNG Jochen; TenneT TSO GmbH, Bayreuth, Germany

E6.5 Cable constraints due to background harmonic amplifi cations

FILLION Yannick, DESCHANVRES Simon, BOUDINET Nathalie; RTE, Paris, France

E6.6 Watertight cable designs in hydropower generation plants

SIVERTSVOLL Børre Johansen, RØNNINGEN Terje; Siemens AS, Trondheim, NorwayFAREMO Hallvard, LERVIK Jens Kristian; SINTEF Energy Research, Trondheim, NorwayHØNSI Kåre, WILNES Rolf; Statkraft Energi AS, Oslo, NorwayHALVORSON Hans Lavoll, JACOBSEN Ole Kristian; BKK Nett AS, Bergen, Norway

F6.1 Materials, ageing

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: F

Chairman: MONTANARI Gian Carlo; DEI - University of Bologna, Italy (to be confi rmed)Rapporteur: CHARRIER Dimitri; Nexans Research Center, France

F6.1.01 A study on the chemical & structural changes of thermally aged XLPE cable insulation by FTIR and thermal analysis techniques

NAGESHWAR RAO Burjupati; Central Power Research Institute, Bangalore, Karnataka, India

F6.1.02 Development of a new liquid antioxidant for stabilizing XLPE compounds or for direct peroxide injection process

LABBÉ Denis; Ecole d’ingénieur de Genève, Geneva, SwitzerlandHILL Jonathan, TAN Siren, RIDER Chris; Addivant Tenax Road, Trafford Park, Manchester, UK

F6.1.03 Dielectric strength of ϒ-radiation cross-linked, high vinyl-content polyethylene

ANDERSSON Mattias, JARVID Markus, MÜLLER Christian; Department of Chemical and Biological Engineering/Polymer Technology, Chalmers University of Technology, Gothenburg, SwedenJOHANSSON Anette, GUBANSKI Stanislaw; Department of Materials and Manufacturing Technology/High Voltage Engineering, Chalmers University of Technology, Gothenburg, SwedenFOREMAN Mark; Department of Chemical and Biological Engineering/Nuclear Chemistry, Chalmers University of Technology, Gothenburg, SwedenANDERSSON Mats; Ian Wark Research Institute, University of South Australia, Mawson Lakes, Australia

F6.1.04 Practical research on upgrading of 10 kV power cable

YAN Biao, ZHOU Li, CHEN Jie, TAO Fengbo; Jiangsu Electric Power Company Research Institute, Nanjing, China

F6.1.05 Ensuring future reliability using manufacturers’ standards to assess cable system performance after installation

HAFNER Gerhard; Wiener Netze, Vienna, AustriaZIEGLER Steffen, LANZ Benjamin; IMCORP, Manchester, USA

F6.1.06 Suggestion of new factors for the PE-based MV cable diagnosis using VLF tan-delta

KIM Sung-min, JEON Si Sik, KIM Dongsub; Korea Electrical Corporation, Jeollanam-do, Republic of Korea

F6.1.07 On the mechanism of leakage conduction in cable dielectrics

CHANDUPATLA Chakradhar Reddy, TIWANA Alampratap Singh; Indian Institute of Technology Ropar, Rupnagar, India

F6.1.08 Effect of carbon black selection on semiconductive compound water content and uptake behavior

BONACCHI Daniele, VAN BELLINGEN Christine; IMERYS Graphite and Carbon, Bodio, SwitzerlandLABBÉ Denis; P&M Cable Consulting LLC, Geneva, Switzerland

F6.2 Diagnosis, maintenance, remaining life, economy

Tuesday June 23rd, 2015 - 14:30 - 16:00 - Room: F

Chairman: MAYER Hans; Consultant, AustraliaRapporteur: ANGOULEVANT Olivier; Prysmian Câbles & Systèmes, France

F6.2.01 The experience in applying new recovery voltage parameters for the impregnated paper insulation cable condition diagnostics

KONONENKO Alexander, HOHRYAKOV Alexey; RISI, Lytkarino, Moscow region, Russia

F6.2.02 Failure experience of Medium Voltage cable heat shrink accessories in Saudi Arabian transmission network

AL DHUWAIAN Abdullah A.; Saudi Electricity Company, Buraydah, Qassim, Saudi Arabia

F6.2.03 On-line monitoring and relative trending of dielectric loss in cross-linked HV cable systems

YANG Yang, DONALD Hepburn, CHENGKE Zhou; Glasgow Caledonian University, Glasgow, UKWENJUN Zhou; Wuhan University, Wuhan, ChinaWEI Jiang, BIN Yang; Wuhan Power Supply Company, Wuhan, China

F6.2.04 Diagnosis of water tree in power cable based on loss current harmonic component energized by variable frequency resonance power source

ZHOU Li, YAN Biao, CHEN Jie, TAO Fengbo; Jiangsu Electric Power Company Research Institute, Nanjing, China

F6.2.05 Solutions for thefts in overhead-underground transition towers in Red Eléctrica de España

MARCELO Alvaro, GARCÍA FERNÁNDEZ Rafael, LÓPEZ-MENCHERO CÓRDOBA Maria Dolores; Red Eléctrica de España, Alcobendas, Madrid, Spain

F6.2.06 PD testing and monitoring of HV cable systems

KOLTUNOWICZ Wojciech, BADICU Laurentiu-Viorel, HUMMEL Rene, BRONIECKI Ulrike, GEBHARDT Daniel; OMICRON Energy Solutions GmbH, Berlin, Germany

F6.2.07 Subsea and EHV cables require a challenging purity degree of XLPE-material

PRUNK Harry, LIEDER Holger; SIKORA AG, Bremen, Germany

F6.2.08 Optasense® distributed acousticsensing (DAS) systems for the power network

SINGH Kuljit; Optasense Ltd, Cody Technology Park, Ively Road, Farnborough, GU14 0LX, Hampshire, UK

F6.2.09 Decision making and forecasting using the data available to utilities - pitfalls, challenges, and case studies of ways forward

WALD Detlef; Eifelkabel, Villmergen, SwitzerlandPERKEL Josh, HAMPTON Nigel; NEETRAC, Atlanta, Georgia, USA

F6.2.10 Resilient 12 to 36 kV touch safe aerial network solution with a competitive total cost of ownership

EFRAIMSSON Lars, HAGMAN Ingvar, ÅHMAN Johan; nkt Cables AB, Falun, Sweden

Tuesday June 23rd, 2015 - 16:30

A7 Testing & Qualifi cation of HVDC cable systems

Tuesday June 23rd, 2015 - 16:30 - 18:00 - Room: A

Chairman: ZACCONE Ernesto; Prysmian Power Link Srl, ItalyRapporteur: BOUDINET Nathalie; RTE, France

A7.1 Qualifi cation of an extruded HVDC cable system at 525 kV

GUSTAFSSON Anders, JEROENSE Marc, GHORBANI Hossein, QUIST Tobias, SALTZER Markus, FARKAS Andreas; ABB AB, High Voltage Cables, Karlskrona, SwedenAXELSSON Fredrik, MONDIET Vincent; ABB AB, Kabeldon, Alingsås, Sweden

A7.2 The space charge characteristic in DC-XLPE cable after 400 kV PQ test

KATAYAMA Tomohiko, YAMAZAKI Takanori, MURATA Yoshinao, MASHIO Shoji, IGI Tsuyoshi; J-Power Systems Corporation, Hitachi-shi, Ibaraki-ken, JapanHOZUMI Naohiro, HORI Masahiko; Toyohashi University of of Technolgy, Toyohashi-shi, aichi-ken, Japan

A7.3 Development and high temperature qualifi cation of innovative 320 kV DC cable with superiorly stable insulation system

ALBERTINI Marco, BAREGGI Alberto, CAIMI Luigi, DE RAI Luca, FRANCHI BONONI Stefano, POZZATI Giovanni; Prysmian SpA, Milan, ItalyBOFFI Paolo; Prysmian Cavi e Sistemi SRL, Milan, Italy

A7.4 Lightning impulse test requirement for HVDC transmission systems

JANSSON Henrik, WORZYK Thomas; ABB AB, Karlskrona, Sweden

A7.5 Space charge evolution in composite XLPE HVDC cable insulation during VSC pre-qualifi cation programme

TZIMAS Antonios, LUCAS Guillaume, DYKE Kevin, PERROT Fabrice; Alstom Grid, Stafford, UKYAGI Yukihiro, TANAKA Hideo; VISCAS Corporation, Ichihara, Chiba, JapanDODD Stephen; University of Leicester, Leicester, UK

A7.6 Cigre WG B1.42: Recommendations for testing DC transition joints for power transmission at a rated voltage up to 500 kV

ARGAUT Pierre; CIGRE SC B1, Paris, France

B7 New materials

Tuesday June 23rd, 2015 - 16:30 - 18:00 - Room: B

Chairman: HJERTBERG Thomas; Borealis AB, SwedenRapporteur: FRELIN Wilfried; EDF R&D, France

B7.1 High performance thermoplastic cable insulation systems for fl exible network operation

VAUGHAN Alun, HOSIER Ian; University of Southampton, Southampton, UKSTEVENS Gary C, PYE Amy, THOMAS Janet, SUTTON Simon; Gnosys Global Ltd, Surrey, UKGEUSSENS Theo; Dow Europe GmbH, Horgen, Zurich, Switzerland

B7.2 Recent developments in cure control for crosslinkable polyethylene (XLPE) power cable insulation

PERSON Timothy, COGEN Jeffrey; The Dow Chemical Company, Collegeville, Pennsylvania, USASUN Yabin; Dow Chemical (China) Investment Co. Ltd., Shanghai, China

B7.3 Self healing high voltage electrical insulation materials

LESAINT Cedric, HESTAD Øystein L., HVIDSTEN Sverre; SINTEF Energy Research, Trondheim, NorwayGLOMM Wilhelm; SINTEF Materials and Chemistry, Trondheim, Norway

B7.4 The characteristics of recyclable thermo-plastic based on polyethylene blends for extruded cables

LI Lunzhi, ZHONG Lisheng, ZHANG Kai, CHEN Guanghui; State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaHOU Shuai, FU Mingli; Electric Power Research Institute of China Southern Power Grid, Guangzhou, Guangdong, China

B7.5 Validation of power cable material technology with reduced degassing burden

SUN Yabin; Dow Chemical (China) Investment Co. Ltd., Shanghai, ChinaPERSON Timothy; The Dow Chemical Company, Collegeville, Pennsylvania, USA

B7.6 Development of a XLPE insulating with low peroxide by-products

MAMMERI Mohamed, DENIZET Isabelle, GARD Jean-Christophe; General Cable, Montereau-Fault-Yonne, France

C7 Cables and systems, modelling and assessment

Tuesday June 23rd, 2015 - 16:30 - 18:00 - Room: C

Chairman: MOSIER Rachel; Power Delivery Consultants, USARapporteur: CHARMETANT Adrien; Nexans, France

C7.1 A study on state assessment method of power cable system to be upgraded

YAN Biao, ZHOU Li, CHEN Jie, WANG Jingjun; Jiangsu Electric Power Company Research Institute, Nanjing, China

C7.2 Validation of a generic tool of kinetic simulation of cable ageing

BEN HASSINE Mouna, MAURIN Romain, MARQUE Grégory; EDF R&D, Moret-sur-Loing, France

C7.3 Identifi cation of cable local thermal stress with time domain refl ectometry

ESPILIT Thierry; EDF R&D, Ecuelles, FranceFRANÇOIS Sandrine; EDF SEPTEN, Lyon, FranceFAGEON Jean-Marie; EDF DPN, Paris, France

C7.4 Modeling and simulation of failures in high temperature superconducting cable for detection and location via time-frequency domain refl ectometry

LEE Geon Seok, KWON Gu Young, CHANG Seung-jin, LEE Chun-kwon, HAN Yee-jin, PARK Jin Bae, SHIN Yong-june; Yonsei University, Seoul, Republic of Korea

C7.5 Maintenance decision models for Java-Bali 150 kV power transmission submarine cable using rams

SILALAHI Zivion, NUGRAHA Herry; PLN Indonesia, Jakarta, IndonesiaSINISUKA Ngapuli; ITB, School of Electrical Engineering and Informatics, Bandung, Indonesia

C7.6 Research on error control of optimal computation combining temperature fi eld with ampacity of cables under complicated conditions

SHAN Jiang; Wuhan Talentum Electric Power CO., TLD, Wuhan, ChinaLI Yin, ZHU Xueliang, ZHAI Guangxin, WANG Wei; State Grid Electric Power Research Institute, Wuhan, China

D7 Specifi c testing trends 2

Tuesday June 23rd, 2015 - 16:30 - 18:00 - Room: D

Chairman: ZENGER Walter; USI, USARapporteur: PAUPARDIN Marie-Laure; General Cable, France

D7.1 Type testing of 150 kV - 161 kV cable system combining AEIC, ICEA and IEC test protocols

JOVANOVIC Ivan; G&W Electric Company, Bolingbrook, IL, USAGEORGALLIS George, CONSTANTINOU Constantinos; Hellenic Cables SA, Marousi, GreeceWU Grand; G&W Electric Company, Shanghai, China

D7.2 Suitability of test voltages applied to high and extra-high voltage extruded cables for quality acceptance during commissioning and for condition assessment during operation

MÄTZOLD Stefan, HAUSCHILD Wolfgang, HENSEL Michael; HIGHVOLT Prüftechnik Dresden GmbH, Dresden, Saxony, Germany

D7.3 New qualifi cation tests for high loaded MV joints

HENNUY Blandine; Laborelec, Linkebeek, BelgiumSTEENNIS Fred, VAN MAANEN Bernd; DNV GL, Arnhem, The NetherlandsDE RIDDER Eddy, STUL Simon; Nexans Network Solutions, Erembodegem, BelgiumAERNS Ben; Alliander, Arnhem, The NetherlandsBOKMA Leon; Westland Infra, Poeldijk, The NetherlandsBUYS Pieter; Stedin BV, Rotterdam, The NetherlandsCOLIN Philippe; ORES, Louvain-La-Neuve, BelgiumMEIER Ralf; 3M, Neuss, GermanyOOSTERLEE Piet; Delta Netwerkbedrijf, Goes, The NetherlandsSEURINCKX Kenny; Eandis, Melle, BelgiumSOEPBOER Piet; Enexis, Den Bosch, The NetherlandsTANZEGHTI Houssam; EDF, Paris, FranceVAN DEN BERG Marcel; Sibelga, Brussels, Belgium

D7.4 Restoring lead alloy solder on cable joint for fl uid fi lled low pressure 145 kV with increasing pressure class

ALMEIDA Geraldo; Techsys Cables, Santo André - SP, BrazilSOUZA Paulo; AES ELETROPAULO, São Paulo - SP, BrazilBARIONI Carlos; Daimom Engenharia, São Paulo - SP, BrazilPINHEIRO Walter; Walter Pinheiro, São Paulo - SP, Brazil

D7.5 Bending stiffness of submarine cables

MAIOLI Paolo; Prysmian SpA, Milan, Italy

D7.6 Improved method of determining bending stiffness of underground cables

TARNOWSKI Janislaw; Hydro-Québec (IREQ), Varennes, Québec, Canada

E7 Material related special features

Tuesday June 23rd, 2015 - 16:30 - 18:00 - Room: E

Chairman: LEEBURN Kieron; CBI Electric, African Cables Ltd, South AfricaRapporteur: MICHON Franck; Prysmian Câbles & Systèmes, France

E7.1 The need to update / upgrade test procedures for connectors used in MV underground joints

FAIRLEY Barry, HAMPTON Nigel, PARKER Thomas; NEETRAC, Atlanta, Georgia, USA

E7.2 Infl uence of expansion on electric fi eld distribution of stress cones for high voltage cable accessories

ZIERHUT Stefan; STRESCON GmbH, Esslingen a. N., Germany

E7.3 Current rating of power cables with temperature limit imposed on backfi ll/duct bank boundary

FARAHANI Alireza, GAROUX Laure, KAMARA Wouleye; CYME Int/Eaton Corp., Montréal, Québec, CanadaANDERS George; Lodz University of Technology, Lodz, Poland

E7.4 The 110 kV cable thermal fi eld analysis based on the thermal path model and simulation calculation

ZHAO Miao, YU Qinxue, ZHONG Lisheng; State Key Laboratory of electrical insulation and power equipment, Xi’an Jiaotong University, Xi’an, ChinaHOU Shuai, FU Mingli; Electric Power Research Institute of China Southern Power Grid, Guangzhou, Guangdong, China

E7.5 Improvements on dry type design for GIS and transformer termination up to 300 kV, by means of adjustable compression force

SEKULA Oldrich, SUN Guoyan; Brugg Kabel AG, Brugg, Aargau, Switzerland

E7.6 Effect of impurities on electric fi eld distribution in HV XLPE insulation

MONAJJED Omar; Liban Cables - Nexans, Beirut, Lebanon

Wednesday June 24th, 2015 - 09:00

A8 Testing of HVDC systems

Wednesday June 24th, 2015 - 09:00 - 10:30 - Room: A

Chairman: STEENNIS Fred; DNV GL - Energy, The NetherlandsRapporteur: HONDAA Pierre; RTE, France

A8.1 Space charge evolution in XLPE HVDC cable with thermal-step-method and pulse-electro-acoustic

TZIMAS Antonios, LUCAS Guillaume, DYKE Kevin, PERROT Fabrice; Alstom Grid, Stafford, UKBOYER Ludovic, MIREBEAU Pierre; Nexans, Calais, FranceDODD Stephen; University of Leicester, Leicester, UKCASTELLON Jérôme, NOTINGHER Petru; Université Montpellier, Montpellier, France

A8.2 Development of an industrial space charge measurement facility for extruded HVDC full scale cables

BOYER Ludovic, MIREBEAU Pierre; Nexans France, Calais, FrancePLOPEANU Mihai; Ofrim Group, Bucharest, RomaniaCASTELLON Jérôme, NOTINGHER Petru, AGNEL Serge; Institut d’Electronique du Sud - Université Montpellier 2, Montpellier, FranceJOSSIEN Dominique, DEPUIDT Yves; Enitram, Dunkerque, France

A8.3 Partial discharge testing of XLPE cables for HVDC: Challenges and opportunities

CAVALLINI Andrea, MONTANARI Gian-Carlo; DEI - University of Bologna, Bologna, ItalyBOYER Ludovic, LUTON Marie-Hélène, MIREBEAU Pierre; Nexans France, Calais, France

A8.4 Laboratory and fi eld partial discharge measurement in HVDC power cables

SELTZER-GRANT Malcolm; HVPD Ltd, Manchester, UK

B8 Material for accessories and sheathing

Wednesday June 24th, 2015 - 09:00 - 10:30 - Room: B

Chairman: BHATTACHARYYA Rohini; Ducab, United Arab EmiratesRapporteur: AIT AMAR Abdellatif; Nexans, France

B8.1 Lifetime prediction of an external protection of cold-shrinkable joint in EPDM rubber subjected to thermal ageing

BEN HASSINE Mouna, TOURCHER Christophe, MARQUE Grégory; EDF R&D, Moret-sur-Loing, FranceNAÏT-ABDELAZIZ Moussa, ZAÏRI Fahmi; Laboratoire de Mécanique de Lille, Villeneuve d’Ascq, FranceCOLLIN Xavier; Laboratoire des Procédés et Ingénierie en Mécanique et Matériaux, Paris, France

B8.2 Fracture behavior and thermo-oxidative ageing of EPDM

KARTOUT Christopher, CRISTIANO-TASSI Antonella, MARQUE Grégory; EDF R&D, Moret-sur-Loing, FranceCRETON Costantino; SIMM - ESPCI, Paris, France

B8.3 Temperature and electric fi eld dependence of XLPE MV cable joint stress control sleeves

ENOKSEN Henrik, HVIDSTEN Sverre; SINTEF Energy Research, Trondheim, NorwaySANDEN Mai-Linn, MAUSETH Frank; Norwegian University of Science and Technology, Dept. of Electric Power Engineering, Trondheim, Norway

B8.4 Effect of silicone rubber’s electric conductance characteristic on interface charge distribution inside XLPE insulated HVDC cable termination

DU Boxue, ZHU Lewei, LI Zhonglei; School of Electrical Engineering and Automation, Tianjin University, Tianjin, ChinaZHAO Hong; Harbin University of Science and Technology, Harbin, China

B8.5 Self-healing cable sheaths in extruded polymeric power cables

RHODES Rhys, GERMAN Ian, STEVENS Gary C; Gnosys Global Ltd, Guildford, Surrey, UK

B8.6 Designing a new inline insulated piercing trough connector for conductor cross-sections 1.5 to 25 mm2

SOEPBOER Piet, LEPPINK Sebastian, BROERSMA Tjeerd; Enexis, ‘s-Hertogenbosch, The Netherlands

C8 Improvement of cable ratings

Wednesday June 24th, 2015 - 09:00 - 10:30 - Room: C

Chairman: KRÄHENBÜHL Francis; Nexans Suisse SA, SwitzerlandRapporteur: BELLOT Frédéric; General Cable, France

C8.i Invited Lecture: “Smart Grids and insulated power cables”

MALLET Pierre; Director for R&D and Innovation in ERDF, France

C8.1 Ampacity and other design considerations for Medium Voltage cables used in renewable energy applications

BASCOM III Earle C. (Rusty); Electrical Consulting Engineers, P.C., Schenectady, New York, USAALLEN JR Richard W.; Consultant, Northboro, Massachusetts, USA

C8.2 Enhanced medium voltage cable ratings by improving cable trench design and thermal conditions

MEIJER Sander, DE WILD Frank; DNV GL, Arnhem, The NetherlandsAL AGHBARI Abdulla, AL NEAIMI Maryam, ASHAAR Muhannad, ALABBADI Mohd; DEWA, Dubai, United Arab Emirates

C8.3 Lifetime extension of medium voltage cables

WOSCHITZ Rudolf, PIRKER Alex; Graz University of Technology, Graz, AustriaSTEURER Herbert; Netz Burgenland Strom GmbH, Eisenstadt, AustriaHESSE Martin; UtiLX Europe GmbH, Bückeburg, Germany

C8.4 Development of the super-capacity insulated wire cable for distribution line

LEE Kyongtae; ILJIN Electric, Kyunggi-Do, Hwasung-Si/Annyoung-Dong, Republic of KoreaLEE Moonseok; SK Chemical, Daejeon-si, Republic of KoreaLEE Mincheol; KEPCO, Kwang-ju, Republic of Korea

D8 Testing evaluations

Wednesday June 24th, 2015 - 09:00 - 10:30 - Room: D

Chairman: GULSKI Edward; onsite hv solutions ag, SwitzerlandRapporteur: GUILLEMIN Martial; RTE, France

D8.1 System impedances for power cable umbilicals

SOLHEIM Kristian Thinn, LERVIK Jens Kristian; SINTEF Energy Research, Trondheim, Norway

D8.2 High voltage XLPE cable partial discharge localization technology based on high frequency signal transmission

BINWU Wang, XUELIANG Zhu, GUANGXIN Zhai; Wuhan Talentum Electric Power CO., TLD, Wuhan, Hubei, ChinaWEI Wang; State Grid Electric Power Research Institute, Wuhan, Hubei, China

D8.3 ICEA standard S-97-682-97 hyperbaric accelerated water treeing test (AWTT) performed at 250 and 310 bar

SMITH III John T.; General Cable Corporation, Scottsville, Texas, USAISUS Daniel; General Cable Corporation, Manlleu, Catalunya, SpainALFORD Michael D., HAJIAGHAJANI Masoud; Chevron Energy Technology Company, Houston, Texas, USAWHIDDON John T.; Aker Solutions - Umbilicals NA, Mobile, Alabama, USA

D8.4 Performing type tests for the qualifi cation of three-core submarine cables and accessories for connections of offshore wind farms

JEGUST Detlef; IPH GmbH Berlin, Berlin, Germany

D8.5 Research and experiments of electromagnetic wave transmission rate in different kinds of cable

BINWU Wang, XUELIANG Zhu, GUANGXIN Zhai; Wuhan Talentum Electric Power CO., TLD, Wuhan, Hubei, ChinaWEI Wang; State Grid Electric Power Research Institute, Wuhan, Hubei, China

D8.6 Measurement of the AC resistance of small cross section power cables

WU Wei Ning, ZHU Shi Jing, LUO Jian Bo, CHEN Xiong, SONG Chang Po, QU Xiao Lei; State Grid Electric Power Research Institute, Nan Jing, Jiang Su Province, ChinaWANG Ying; Prysmian Group, Milan, Italy

E8 New cable and accessories monitoring applications

Wednesday June 24th, 2015 - 09:00 - 10:30 - Room: E

Chairman: SYTNIKOV Victor; R&D Center @FGC UES, RussiaRapporteur: LENCOT Gérard; Prysmian Câbles & Systèmes, France

E8.1 The introduction of PD detection with on-line PD diagnosis system in EHV underground power cable

KIM Jae-seung, ROH Tae-hyueng, KIM Dong Kyu, KIM Jin, KIM Youn Chan; KEPCO, Seoul, Republic of Korea

E8.2 Toward acoustic detection of partial discharges in high voltage cables

CZASZEJKO Tadeusz, STEPHENS Jarman; Monash University, Melbourne, Victoria, Australia

E8.3 Development of advanced partial discharge measurement for XLPE cable system

TAKAHASHI Toshihiro, NOZAWA Yusuke, OKAMOTO Tatsuki; Central Research Institute of Electric Power Industry (CRIEPI), Yokosuka, Japan

E8.4 On-line partial discharge screening of MV and HV cables: feasibility and potential

MONTANARI Gian-Carlo; University of Bologna, Bologna, ItalyHEBERER Stephan, SCERBO Luigi; Techimp, Bologna, Italy

E8.5 Ultrasonic extrusion quality monitoring of multilayer HV cables during production

HUMPHREYS-JONES Gareth; Acuity Products Limited, St. Asaph, UK

E8.6 Laboratory investigation of a service aged HV cable termination

TAMUS Zoltán Ádám, CSÁNYI Gergely Márk; Budapest University of Technology and Economics, Budapest, Hungary

Wednesday June 24th, 2015 - 11:00

A9 Materials and space charges

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: A

Chairman: MARZINOTTO Massimo; Terna S.p.A., ItalyRapporteur: EYSSAUTIER Quentin; Nexans, France

A9.1 Observation of space charge accumulation in cable insulating materials at voltage polarity reversal

TANAKA Yasuhiro, KODERA Ryota, KATO Tsuyoshi, MIYAKE Hiroaki; Tokyo City University, Tokyo, JapanMORI Hiroki, YAGI Yukihiro; VISCAS Corporation, Ichihara, Chiba, Japan

A9.2 Space charge distribution in XLPE plates with non-uniform conductivity

OLSSON Carl-Olof, KÄLLSTRAND Birgitta, LUNDMARK Maria, JOHANSSON Kenneth, ARNSTEN Sara, MA Bin; ABB AB, Corporate Research, Västerås, SwedenSALTZER Markus, JEROENSE Marc; ABB AB, High Voltage Cables, Karlskrona, Sweden

A9.3 Behaviors of water tree propagation after accelerated aging under different polarity DC voltages

ZHOU Kai, LI Tianhua, YANG Mingliang, HUANG Ming, LI Kangle; School of Electrical Engineering and Information, Sichuan University, Chengdu, Sichuan, China

A9.4 Development of XLPE nano-composite used for HVDC ±250 kV cable system compatible with LCC and VSC

NAM Jin-ho, PARK Wan-ki; LS Cable & System, Gyeongi, Republic of KoreaJEON Seung-ik; LS Cable & System, Gyeongbuk, Republic of KoreaLEE In-ho; LS Cable & System, Gangwon, Republic of KoreaHWANGBO Seung; Honam University, Gwangju, Republic of KoreaKIM Jeong-tae; Daejin University, Gyeongi, Republic of KoreaLEE June-ho; Hoseo University, Chungnam, Republic of KoreaKOO Ja-yoon; Hanyang University, Gyeongi, Republic of Korea

A9.5 Research and development of ±320 kV fl exible HVDC power cable

HU Ming; Zhongtian Technology Submarine Cable Co., Ltd, Nantong, ChinaXIE Shuhong, WU Xiaowei; Zhongtian Technology Group Co., Ltd, Nantong, China

A9.6 Triple jumps of XLPE insulated HVDC cable development in China: From 160 kV, 200 kV to 320 kV

XIE Shuhong; Zhongtian Technology Group Co., Ltd, Nantong, ChinaFU Mingli; China South Power Grid International Co., Ltd, Guangzhou, Guangdong, ChinaYIN Yi; Shanghai Jiao Tong University, Shanghai, China

B9 Material performances

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: B

Chairman: GOCKENBACH Ernst; Leibniz Universität Hannover, Germany (to be confi rmed)Rapporteur: NOTINGHER Petru; Institut d’Électronique du Sud - Université Montpellier 2, CNRS,

France

B9.1 High quality carbon black to surpass traditional solution for HV semicons?

BONACCHI Daniele, VAN BELLINGEN Christine; IMERYS Graphite and Carbon, Bodio, SwitzerlandLABBÉ Denis; P&M Cable Consulting LLC, Geneva, Switzerland

B9.3 Non-contact surface metrology of degraded conductor screens in XLPE cables

HOELTO Jorunn, BAKKEN Kristine, HVIDSTEN Sverre; SINTEF Energy REsearch, Trondheim, Norway

B9.4 Remnant static mechanical stresses and water tree ageing of XLPE power cables

ILDSTAD Erling, GROV-PLASSEN Kurt Albert; Norwegian University of Science and Technology, Trondheim, NorwayFAREMO Hallvard; SINTEF Energy Research, Trondheim, Norway

B9.5 Evaluation of degradation of PVC by dielectric spectroscopy, and SEM and FTIR analyzes

HANDALA Mohand Amokrane, ZEBOUDJ Farida; University Mouloud Mammeri, Tizi-Ouzou, AlgeriaBELHITECHE El Hadi; Université Med Boudiaf, M’sila, Algeria

B9.6 The infl uence of operating conditions of cable lines in grids on selected properties of extruded cable insulation

ZAWODNIAK Jozef Jacek; ENEA Operator S.A., Poznan, PolandRAKOWSKA Aleksandra; Poznan University of Technology, Poznan, Poland

C9 Special Cables - Avionics

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: C

Chairman: SCHUTTEN Jan; Prysmian Group, The NetherlandsRapporteur: JEANGUILLAUME Alain; Draka Fileca, France

C9.i Invited Lecture: “Impact of the new electrical architecture of aircraft on insulated power cables”

ROQUES Serge; Emeritus Expert in SAFRAN Group, France

C9.1 New cable family for new power supply need in aerospace environment

IGNAZI Pierre, GAUCHY Stéphane; DRAKA FILECA, Sainte Geneviève, France

C9.2 Validating and quantifying reliability improvements of new cable designs - A case study of 600 V self sealing cables

FLETCHER Chris; Duke Energy, Charlotte, NC, USAMCAULIFFE Joe; Southwire, Carollton, USAPERKEL Josh; NEETRAC, Atlanta, Georgia, USA

C9.3 Low bending radius aerospace power feeder cables for reliable electrical architectures of more electrical aircrafts

DAUMAND Thierry, LECLUSE Wilfried, PINTO Olivier, RYBSKI Patrick; Nexans, Draveil,

D9 Environment and sustainability 1

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: D

Chairman: ZHONG Lisheng; State Key Laboratory of electrical insulation and power equipment, Xi’an Jiaotong University, China

Rapporteur: MOINDROT Vincent; RTE, France

D9.1 Feedback on the management of transmission lines magnetic fi elds in France

CABAU Matthieu, LESUR Frédéric, DESCHAMPS François; RTE, Paris, France

D9.2 Failures in underground power cables - return of experience

VAN MAANEN Bernd, PLET Cornelis, VAN DER WIELEN Peter, MEIJER Sander, DE WILD Frank, STEENNIS Fred; DNV GL, Arnhem, The Netherlands

D9.3 Assessment of environmental impact of submarine cables and offshore connections

SAFFROY Damien, LESUR Frédéric, RAOUX Aurore; RTE, Paris, France

D9.4 Choice of electrically conductive plate for shielding the magnetic fi eld from underground high voltage cables

SUN Guoyan, RIESINGER Jens, SEKULA Oldrich, CORSARO Pietro; Brugg Kabel AG, Brugg, Aargau, Switzerland

D9.5 Heat dissipation of high voltage cable systems - a technical and agricultural study

BRÜGGMANN Jan, JUNGNITZ Ludger, UTHER Dirk; Amprion GmbH, Dortmund, GermanyTRÜBY Peter; Albert Ludwigs University, Freiburg, Germany

D9.6 Thermal ratings of submarine HV cables informed by environmental considerations

HUGHES Tim, HENSTOCK Tim, PILGRIM James A., DIX Justin, GERNON Tom, THOMPSON Charlie; University of Southampton, Hants, UK

E9 Design of LV MV cable systems

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: E

Chairman: FALCONER Antony; Aberdare Cables, South AfricaRapporteur: BÉNARD Laurent; Prysmian Câbles & Systèmes, France

E9.1 Copper-clad aluminum as an alternative to copper fl exible conductors for electric power cables: opportunities and challenges

BAREGGI Alberto, CASIRAGHI Flavio, DE RAI Luca, MARTELLI Davide; Prysmian SpA, Milan, ItalyMAZZUCATO Alessandro; Prysmian Cavi e Sistemi Italia SRL, Milan, ItalyPERUZZOTTI Franco, PEZZONI Antonio; Dynext SRL, Legnano, Milan, ItalyANELLI Pietro; G.B. Studio, Milan, ItalyFOX Dustin, YANCE Syarif; Copperweld, Nashville, Tennessee, USA

E9.2 Connection to MV cable longitudinal aluminium screen

TOURCHER Christophe; EDF R&D, Moret-sur-Loing, FranceSIMEON Eric; SYCABEL, Paris, FranceTAMBRUN Roger; ERDF, Paris La Défense, France

E9.3 Comparative study of circuit integrity cable designs and materials for Australian/New Zealand market

IVANOV Ivan, ALEXANDER Graeme; Nexans Olex, Melbourne, Victoria, Australia

E9.4 Electro-thermal analysis of low and medium voltage cable joints

GOUDA Ossama; Cairo University, Cairo, Egypt

E9.5 Mechanical connectors used inside MV accessories: A system approach

QUAGGIA Dario, TOGNALI Stéphane; Prysmian Group, Milan, ItalyLENCOT Gérard; Prysmian Group, Marne la Vallée, France

E9.6 Catalyst alternatives to replace DBTDL to crosslink silane grafted polyethylene

LEVIGOUREUX Sophie, GARCIA Pedro, FICQUENET Marjorie, DENIZET Isabelle; General Cable, Montereau-Fault-Yonne, France

F9.1 LV, MV, HV, EHV and future cables

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: F

Chairman: JEON Seung-ik; LS Cable & System, Republic of KoreaRapporteur: BOYER Ludovic; Nexans, France

F9.1.01 Cables with smooth welded aluminum sheath

JEOUNG Bumyong, KIM Jinwoo, MUN Byeongcheol, KIM Daeyoen, KIM Youngjun, LEE Kyongtae, KIM Jungsik; ILJIN Electric, Hwasung-Si, Kyunggi-Do, Republic of Korea

F9.1.02 Expanding the performance potential of the universal cable system by the use of DOW endurance ™ HFDC-4202 EC water tree retardant crosslinked polyethylene insulation

BRIGANDI Paul; Dow Electrical & Telecommunications USA, Collegeville, Pennsylvania, USAANDERSSON Christian, BRINGSELL Håkan; nkt Cables AB, Falun, SwedenCREE Stephen; Dow Electrical & Telecommunications Europe, Horgen, Zurich, Switzerland

F9.1.03 Effect of the fault impedance on the performance of directional over current relays in medium voltage power cables- a case study

AMIN Ahmed; Dar Engineering, Cairo, Egypt

F9.1.04 Investigation of temperature dependence of DC diagnostic tests on LV PVC insulated cables

TAMUS Zoltán Ádám, CSÁNYI Gergely Márk, TOMON Gergely; Budapest University of Technology and Economics, Budapest, Hungary

F9.1.05 Urban 220 kV cable transmission: perpetual developments

SONAR Vikas, PATIL Vikrant; Pune University, Pune, Maharashtra, IndiaBAGDE Sanjeev; Nagpur Univerisity, Nagpur, Maharashtra, IndiaSHARMA Arvind; Gorakhpur University, Gorakhpur, Uttar Pradesh, India

F9.1.06 The completion of 275 kV Suruga-Higashishimizu line

OGAWA Tomoya; Chubu Electric Power Co., Inc, Nagoya, Japan

F9.1.07 A study on the thermal behavior characteristic of 345 kV underground transmission line XLPE cable

LEE Jihun, KO Yongwoo, HONG Dongsuk; Taihan Electric Wire Co., Ltd, Seoul, Republic of KoreaBAE Juho, KIM Dujin, KOO Donggheol, LEE Euichan; Korea Electric Power Corporation, Seoul, Republic of Korea

F9.1.08 Effect of water fi lled voids on the thermo-electrical behaviour of XLPE insulated cables using FEA method

MECHERI Yacine, BOUAZABIA Slimane, BOUHADDICHE Rafi k; Université des Sciences et de la Technologie USTHB, Bab-Ezzouar, Algiers, Algeria

F9.1.09 Hybrid energy transfer lines with liquid hydrogen and superconducting cable - prototypes of future high power lines

VYSOTSKY Vitaly, FETISOV Sergey; Russian Scientifi c R&D Cable Institute, Moscow, Russia

F9.1.10 Syntactic foam as an alternative electrical insulation material for superconducting cable systems

WINKEL Daniel, PUFFER Ralf, SCHNETTLER Armin; RWTH Aachen University, Aachen, Germany

F9.2 Cables and accessories design-Modelling

Wednesday June 24th, 2015 - 11:00 - 12:30 - Room: F

Chairman: CHANG Michael; Nexans, China (to be confi rmed)Rapporteur: PELTON Guillaume; ERDF, France

F9.2.02 Electric fi eld distribution in polyethylene insulation used in the electric cables affected by water trees in the presence of space charges

MEZIANI Madjid, MEKHALDI Abdelouahab, TEGUAR Madjid; Ecole Nationale Polytechnique d’Alger, El-Harrach, Algiers, Algeria

F9.2.03 Thermal capability of the XLPE power cable jacket under fault conditions

DANG Chinh; Hydro-Québec Technologie, Varennes, Québec, CanadaALIBHAY Saleman; Hydro-Québec Équipement, Montréal, Québec, CanadaCÔTÉ Jacques; Hydro-Québec Distribution, Montréal, Québec, Canada

F9.2.04 Transient analysis of 3-core SL-type submarine cables with jacket around each core

ANDERS George; Lodz University of Technology, Lodz, PolandGEORGALLIS George; Hellenic Cables, Athens, Greece

F9.2.05 Cable joint to FFLP cable for provisional repair with quick installation

ALMEIDA Geraldo; Techsys Cables, Santo André - SP, BrazilVASCONCELLOS Gil; Matrixenergia, São Paulo - SP, BrazilTALHOFER Fellipe; LIGHT SA, Rio de Janeiro, RJ, Brazil

F9.2.06 Design and analysis of high current heat cycles test set for underground cable

PHAYOMHOM Att; Metropolitan Electricity Authority, Bangkok, Thailand

F9.2.07 Thermal dissipation analysis of underwater towed-cable with impulse current using FEM

PAN Pan, CAI Bingyu, ZHANG Jianmin, XUE Jianlin; Zhongtian Technology Submarine Cable Co., Ltd, Nantong, ChinaXIE Shuhong; Zhongtian Technology Group Co., Ltd, Nantong, China

F9.2.08 Thermal bottlenecks in Landfall - 3-core submarine cables

STØLAN Ronny, OLSEN Espen, HATLO Marius; Nexans Norway AS, Halden, Norway

F9.2.09 Replacement of porcelain bushings with polymeric bushings in HV underground XLPE cable termination box

KIM Jae-seung, ROH Tae-hyueng, KIM Dong Hyu, KIM Jin, KIM Youn Chan; KEPCO, Seoul, Republic of Korea

F9.2.10 Computationally light two-zone moisture migration modelling for underground cables - critical temperature vs. Critical heat fl ux

MILLAR Robert John, DEGEFA Merkebu, LEHTONEN Matti; Aalto University, Espoo, Finland

F9.2.11 A novel lumped l-C ladder method for computing switching overvoltages in EHV long shunt-compensated cables

BENATO Roberto, DAMBONE SESSA Sebastian; University of Padova-Department of Industrial Engineering, Padova, ItalyPIETRIBIASI Davide; Prysmian Power Link, Milan, Italy

F9.2.12 Development of a 500 kV PPLP MI cable system for HVDC applications

JUNG Eui-hwan, KIM Sung-yun, CHAE Byung-ha, YOON Hyun-sung, KANG Chae-hong, LEE Su-kil, JEON Seung-ik; LS Cable & System, Gu-mi, Gyeongbuk, Republic of Korea

Wednesday June 24th, 2015 - 14:30

A10 HVDC transient phenomena

Wednesday June 24th, 2015 - 14:30 - 16:00 - Room: A

Chairman: JIANG Yun; Shanghai Electric Power Company, China (to be confi rmed)Rapporteur: LUTON Marie-Hélène; Nexans France, France

A10.1 The study on the transient electric fi eld distribution of HVDC cable

LI Zhonghua, LIU Lele, GUO Wenmin, CHEN Yu; Harbin University of Science and Technology, Harbin, China

A10.2 Modeling of DC cables for transient studies

NGUYEN TUAN Minh; EDF R&D, Moret-sur-Loing, FranceXEMARD Alain; EDF R&D, Clamart, FranceWOLFF Quentin; EDF CIST, Saint-Denis, France

A10.3 Transient thermal phenomenon in HVDC extruded cables under test and operating condition - numerical simulation and measurements

LUTON Marie-Hélène; Nexans France, Calais, FranceFROHNE Christian; Nexans Germany, Hannover, GermanyKARLSTRAND Johan; JK Cablegrid Consulting AB, Karlskrona, Sweden

A10.4 Transients on DC cables connected to VSC converters

DENNETIERE Sebastien, SAAD Hani, HONDAA Pierre, NAUD Antoine; RTE, Paris La Défense, France

A10.5 Transient space charge phenomena in HVDC model cables

VU Thi Thu Nga (*), TEYSSEDRE Gilbert, VISSOUVANADIN Bertrand, STEVEN John Yuddy, LAURENT Christian; Laboratoire Plasma et Conversion d’Energie, Université Paul Sabatier, Toulouse, France(*) second affi liation: University Power Electric, Hanoi, Viet Nam

A10.6 On the way to compare the polarity reversal withstand capability of HVDC mass-impregnated and extruded cable systems

MARZINOTTO Massimo; TERNA S.p.A., Rome, ItalyMAZZANTI Giovanni; University of Bologna, Bologna, ItalyVERCELLOTTI Uberto; CESI S.p.A., Milan, ItalyJAHN Heiko; FGH Engineering & Test GmbH, Mannheim, Baden Württemberg, Germany

B10 Cables for the future

Wednesday June 24th, 2015 - 14:30 - 16:00 - Room: B

Chairman: RAKOWSKA Aleksandra; TU Poznan University of Technology, Polytechnika Poznanska, Poland

Rapporteur: MIREBEAU Pierre; Nexans France, France

B10.1 Update on world’s fi rst superconducting cable and fault current limiter installation in a German city center

STEMMLE Mark; Nexans Deutschland GmbH, Hannover, GermanyMERSCHEL Frank; RWE Deutschland AG, Essen, GermanyNOE Mathias; Karlsruhe Institute of Technology, Karlsruhe, GermanyHOBL Achim; Nexans SuperConductors GmbH, Hürth, Germany

B10.2 Development of termination for HTS cable

ADACHI Kazuhisa, HENMI Kiyoshi, NAKANISHI Tatsuhisa, MIDO Nobuhiro, SEMA Nobuyuki, HASEGAWA Takayo; SWCC Showa Cable Systems Co Ltd, Sagamihara-city, Kanagawa-pref, Japan

B10.3 The test results of superconducting AC and DC cables in Russia

SYTNIKOV Victor, BEMERT Sergey, ROMASHOV Maxim; R&D Center @FGC UES, Moscow, Russia

B10.4 Current status of development and demonstration of HTS power cable system in Korea

JANG Yongseo, KIM Youngwoong, KIM Yanghoon, CHOI Changyoel, RYU Cheolhwi, SUNG Heogyung; LS Cable & System, Gunpo-si, Gyeonggi-do, Republic of Korea

B10.5 High power underground transmission lines

IMAMOVIC Denis, TENZER Michael, KOCH Hermann; Siemens AG, Erlangen, Germany

C10 Industrial and special cables

Wednesday June 24th, 2015 - 14:30 - 16:00 - Room: C

Chairman: ROVIRA Jacint; Groupo General Cables Sistemas SA, SpainRapporteur: BEN HASSINE Mouna; EDF R&D, France

C10.1 Development of an alternative solution to mica tape for fi re resistant cables

WALD Detlef; Eifelkabel, Villmergen, SwitzerlandORTON Harry; Orton Consulting Engineers International, North Vancouver, CanadaDI Jimmy; Volsun Electronics, Suzhou, China

C10.2 Cables for oil, gas and petrochemical industry

THOMBRE Arun, MOURAD Bahaa; DUCAB, Dubai, United Arab Emirates

C10.3 Acceptance criteria in nuclear power plant cable qualifi cation

PLAČEK Vít, KÁBRT Jan, HNÁT Vladimír, ŽÁK Pavel; UJV Rez, a. s., Hlavní 130, Rez, 250 68 Husinec, Czech Republic

C10.4 Electrical performance improvement of cross-linked polyethylene cables using inorganic fi ller

ESSAWI Sherif; Electrical Power Dept., Petrojet, Cairo, EgyptSAAD Loai; Electrical Power and Machines Eng. Dept., Aswan University, Aswan, EgyptASAAD Jeanette; Polymers and Pigments Dept., National Research Center, Cairo, EgyptMOSTAFA Mahmoud; Electrical Power and Machines Eng. Dept., Ain Shams University, Cairo, Egypt

C10.5 Determination of fi re behavior of polymer cable materials and mathematical modeling of highly-fi lled halogen-free compound burning

SHUVALOV Mikhail, KAMENSKIY Mikhail, KRYUCHKOV Aleksandr, STEPANOVA Tatiana, FRIK Andrey, SAVIN Dmitry; VNIIKP, Moscow, Russia

D10 Environment and sustainability 2

Wednesday June 24th, 2015 - 14:30 - 16:00 - Room: D

Chairman: KOEPFER Rolf; SYCABEL, FranceRapporteur: BARBEAU Sophie; Nexans, France

D10.1 Life cycle assessments of extruded AC and DC power cable systems

HAERING Dominik, SCHROEDER Gero, SAAM Christoph, WEINLEIN Andreas, BOSSMANN Axel; Südkabel GmbH, Mannheim, Baden Württemberg, Germany

D10.2 Life cycle assessment improvement medium voltage cable for French market

HOUSTIN Amélie; General Cable, Montereau-Fault-Yonne, France

D10.3 Circular economy concept for power cables

SLUIJER Harrie, VAN ROSSUM Jos, MIDDEL Frank, LAUWERS Sander, TAMMENGA Hanneke, LAMBALLAIS Lawrence, SNAAK Emma; Prysmian Netherlands B.V., Delft, The NetherlandsHERMANS Dominique, VAN SLOGTEREN John, ERKAMP Martin, DE VRIES Hendrik; Alliander, Arnhem, The Netherlands

D10.4 Controlling fl uid leaks in damaged fl uid fi lled cables

RHODES Rhys, STEVENS Gary C, GERMAN Ian; Gnosys Global Ltd, Guildford, Surrey, UKLAURICHESSE Delphine, BERTRAND Yves; EDF R&D, Moret-sur-Loing, France

D10.5 Condition assessment of high voltage (22 kV) aerial bundled cable (ABC)

MUXWORTHY Martin, MAFFEI Mark, ALEXANDER Graeme; Nexans Olex, Tottenham, Victoria, Australia

D10.6 Comparison of quickfi eld simulation of three single core XLPE cables, in fl at formation, with complex loading, between not taking drying out and taking drying out of soil into account

LE ROUX Joubert; Vaal University of Technology, Vanderbijlpark, South Africa

E10 Challenging environment

Wednesday June 24th, 2015 - 14:30 - 16:00 - Room: E

Chairman: BECKER Jean; Nexans / SART Consult, BelgiumRapporteur: COLOMBIER Serge; Prysmian Câbles & Systèmes, France

E10.1 CPR (construction products regulation) on medium and low voltage distribution cables for Spanish electric utilities

GENERÓ Neus, CALVERAS Daniel; General Cable, Manlleu, Catalunya, SpainPADILLO Francesc, MAURI Manel; Prysmian, Vilanova i la Geltrú, Catalunya, SpainBARGALLÓ Jordi; Top Cable, Rubí, Catalunya, Spain

E10.2 Accelerated aluminum corrosion upon water ingress in damaged low voltage underground power cables

KRUIZINGA Bart, WOUTERS Peter; Eindhoven Unversity of Technology, Eindhoven, The NetherlandsSTEENNIS Fred; DNV GL - Energy, Arnhem, The Netherlands

E10.3 Long-term effect of water tree aged cables injected by silicone liquid under continuous electrical and thermal stress

LI Kangle; Sichuan University, Chengdu, China

E10.4 Assessing smoke and heat release during combustion of electric cables using cone calorimeter

BURJUPATI Nageshwar Rao, ARUNJOTHI R.; Central Power Research Institute, Bangalore, Karnataka, India

E10.5 Lethal combustion product evaluation of polymeric materials used in power cables

NAGESHWAR RAO Burjupati; Central Power Research Institute, Bangalore, Karnataka, India

E10.6 High safety and low maintenance aerial cable system withstanding extreme weather

EFRAIMSSON Lars, HAGMAN Ingvar, KÖHLER Jan, BRINGSELL Håkan; nkt Cables AB, Falun, Sweden

A11 Closing session

Wednesday June 24th, 2015 - 16:30 - 18:00 - Room: A

The Closing session will include three parts:

Round Table: World researches on HVDC materials, cables and cable systems

Jicable’15 Young Researcher Awards

Jicable’15 Award and closing of the Conference