    A substation is an assembly of apparatus, which transformthe characteristics of electrical energy from one form toanother say from one voltage level to another level.

    The switch house building of the G.S.S. has following parts:-

  • 7/31/2019 Sunny Jai Kmr Kukreja

    3/26

    The substation divided into two broad sections :-

    1. The switchyard

    2. The control room

  • 7/31/2019 Sunny Jai Kmr Kukreja

    4/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    5/26

    In this substation the power is coming from five places namely:-

    Outgoing feeders are:-

  • 7/31/2019 Sunny Jai Kmr Kukreja

    6/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    7/26

    Lighting arrestor is a device, which protects the overhead lines and other

    electrical apparatus viz, transformer from overhead voltages and lighting .

  • 7/31/2019 Sunny Jai Kmr Kukreja

    8/26

    When to carry out inspection or repair in the substationinstallation a disconnection switch is used called isolator. Its

    work is to disconnect the unit or section from all other line partson installation in order to insure the complete safety of staffworking. The isolator works at no load condition. They do nothave any making or breaking capacity.

    The isolating switches can broadly divided into followingcategories: -

    Bus isolator .

    Line isolator cum earthing switch .

    Transformer isolating switch.

  • 7/31/2019 Sunny Jai Kmr Kukreja

    9/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    10/26

    50Hz power supply also carries communication signals at high frequencyTrap is a device used for this purpose. It traps the frequency of desired levelfor communication and sends it to P.L.C.C. department. It is used to trap thecommunication signal & send PLCC room through CVT.

  • 7/31/2019 Sunny Jai Kmr Kukreja

    11/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    12/26

    AIR BLAST CIRCUIT BREAKER

  • 7/31/2019 Sunny Jai Kmr Kukreja

    13/26

    A transformer is a device that transfers electrical energy from one circuit toanother through inductively coupled conductor -the transformer's coils A

    varying current in the first or primary winding creates a varying magneticflux in the transformer's core and thus a varying magnetic field through thesecondary winding This varying magnetic field induces a varying electro-motive force, or voltage in the secondary winding This effect is calledmutual induction.

  • 7/31/2019 Sunny Jai Kmr Kukreja

    14/26

    When current in a circuit is too high to directly apply to measuringinstruments, a current transformer produces a reduced current

    accurately proportional to the current in the circuit, which can beconveniently connected to measuring and recording instruments Acurrent transformer also isolates the measuring instruments fromwhat may be very high Current transformer is a instrumenttransformer which is mainly used for measuring currents where veryhigh currents are flowing.

  • 7/31/2019 Sunny Jai Kmr Kukreja

    15/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    16/26

    To step up or step down the voltage and transfer powerfrom one a.c voltage another a.c voltage at the same

    frequency.

  • 7/31/2019 Sunny Jai Kmr Kukreja

    17/26

    100 MVA,220KV/132KV POWER TRANSFORMER

  • 7/31/2019 Sunny Jai Kmr Kukreja

    18/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    19/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    20/26

  • 7/31/2019 Sunny Jai Kmr Kukreja

    21/26

    The conductors used :-

    For 400 kV line:Taran Tulla and Marculla conductor.

    For 220 kV line: Zebra conductor is used composite of Aluminumstrands and Steel wires.

    For132 kV line: Panther conductor is used composite ofAluminum strands and Steel wires.

    The material used in these conductors is generally Aluminum

    Conductor Steel Reinforced (ACSR). The conductors run over thetowers cross arms of sufficient height with the consideration tokeep safe clearance of sagged conductors from ground level andfrom the objects (trees, buildings etc.) either side also.