superior quality heat interface units€¦ · hiu products that are suitable when designing...

36
SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL Pegler Yorkshire

Upload: others

Post on 31-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

SUPERIOR QUALITY HEAT INTERFACE UNITSPUTTING YOU IN CONTROL

Pegler Yorkshire

Page 2: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

2

PUTTING YOU IN CONTROLDiverse industry expertise combined with cutting-

edge technological innovation mean Pegler Yorkshire’s

Control solutions help you overcome unique

challenges and meet the highest standards in

both performance and system aesthetics.

PERFORMANCE WITH PRECISIONPegler Yorkshire’s Control products enable you to balance precision fl ow control, energy effi ciency and comfort through innovative products and systems that ensure building performance criteria are met and the resulting installation is easy, effi cient and economical to operate.

Our comprehensive Terrier, Meibes and Ballorex product ranges offer proven energy saving solutions, exceptional accuracy and optimised system performance – so, whatever your project or challenge, you can be sure you’ll always be in control.

GLOBAL EXPERIENCE, COMBINED EXPERTISEWith over 100 years of manufacturing and innovation combined with extensive industry knowledge and worldwide market experience, Pegler Yorkshire offers the most advanced and complete Connect & Control systems on a global scale.

As one of Britain’s largest and most respected manufacturers and suppliers of products for the plumbing and heating industries, Pegler Yorkshire is confi dent we can provide you with all the controls, connections and support your project requires.

For more information visit www.pegleryorkshire.co.uk

Pegler Yorkshire

Page 3: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

3

Pegler Yorkshire is pleased to be associated with several infl uential industry organisations:

ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTSIntroduction 4A comprehensive range for all applications 4-5Service 6Energy effi ciency with improved SAP ratings 7

A TOTAL SUPPORT PACKAGE FOR SPECIFIERS, CONTRACTORS AND FACILITIES MANAGERSBenefi ts 8Choosing the best system for your application 9-11

PRODUCT DETAILSProduct focus 12-13A2 RX Blu-Climate range 14-17A2 UX Blu-Climate range 18-21A1 RX Blu-Climate range 22-25A1 CX Blu-Climate range 26-29

TECHNICAL GLOSSARY 30-31

DISTRICT HEATING SYSTEMS CLIMATE CONTROL 32-33

CONTENTS

Association ofPlumbing and

Heating Contractors

The BathroomManufacturers

Association

British PlumbingEmployers Council

The CopperDevelopmentAssociation

The UKCopper Board

The Chartered Institution of Building Services Engineers

ThermostaticMixing Valve

ManufacturersAssociation

Institute ofPlumbing

Scottish and Northern IrelandPlumbing Employers

Federation

ConstructionProducts

Association

The Brass Page for specifi ers, designers,

engineers and manufacturers

Brass pecCERTIFICATION LTD

Builders MerchantsFederation

The UK District Energy Association

Page 4: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTS

4

The Meibes brand and German heritage is renowned for its precision engineering quality and

innovative designs that deliver unparalleled performance, effi ciency and ease of installation.

Meibes Heat Interface Units (HIUs) facilitate the use of centralised systems for space heating and domestic hot water in multi-residential buildings. They are high performing units, engineered with fully tested and approved components, designed to provide optimum performance for end users, while ensuring that they are easy to install and maintain.

The Meibes HIUs offered by Pegler Yorkshire have been designed to meet the specifi c needs of the UK market. For example, Meibes HIUs for the UK are confi gured for top-entry pipework for ease of installation in ceiling voids

Pegler Yorkshire also holds a comprehensive range of spares for fast delivery throughout the UK.

Meibes HIUs are pre-fabricated units linked to the central heat source(s) via a network of three pipes – heating fl ow and return and a separate potable water feed. A zone valve in each unit, linked to a standard timer and room thermostats, controls the space heating for each apartment.

A patented Proportional Modulating (PM) valve intelligently prioritises the requirement for domestic hot water (DHW) over heating, in a similar way to a combi boiler.

A COMPREHENSIVE RANGE FOR ALL APPLICATIONSThe breadth of the Meibes HIU range delivers solutions for all types of centralised heating networks serving multi-residential accommodation, ensuring effective control of heating and DHW in apartments and other spaces. The design of HIUs facilitates a balanced system that delivers consistent performance, irrespective of variation in hot water demands or how far the units are from the plant room.

TYPICAL APPLICATIONS Private apartments

Local Authority accommodation

Housing Associations

Student accommodation

Nurse accommodation

Sheltered housing.

Page 5: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

5

DESIGN

Performance

Pegler Yorkshire has various high performance Meibes HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use and against the overall building requirements. Guidance on network and temperature fl ow rates can also be provided by the Pegler Yorkshire team.

Allocating design space

Meibes HIU headline A2 RX Indirect Heating and Domestic Hot Water units are compact in size at only 500mm wide, enabling them to be fi tted into minimal cupboard space. This also provides the option to fi t them into an appliance space. Further options are also available for direct heating units at 650mm wide.

UK solution

Pegler Yorkshire ensures that UK experience, system design and installation and practices drive the solution to the product, which is why the Meibes range of HIUs is designed to meet UK needs. As a result there is no need to compromise and adapt to HIU’s with a European confi guration.

BUILD

Installation innovation

The Meibes HIU range is part of Pegler Yorkshire Connect & Control, which fully recognises the importance of minimising installation costs whilst ensuring the building performs effi ciently and optimally. Meibes HIUs were one of the fi rst to be designed with a fi rst fi x rail which is available to aid staged installation, supporting the primary network set-up.

No special commissioning required

Meibes HIUs are designed to remove complications and provide clarity on installation. There is no need to have a specialist for commissioning as the standard installation process requires a competent installer to simply follow the specifi er’s set-up parameters.

Expertise

Pegler Yorkshire is one the leading manufacturers of commercial plumbing and heating systems. Our expertise and experience enables contractors to benefi t signifi cantly when it comes to project costs, and technical and service support, by using a connect and control system they can trust.

“Whatever the application, Meibes HIU have the authoritative solution”

Page 6: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

ENERGY EFFICIENT SOLUTIONS SUITABLE FOR CENTRALISED BOILER PLANTS

6

SERVICE

Guarantee

Pegler Yorkshire provides ultimate engineering and performance confi dence. Down time can lead to client frustration and experience is the key to a well-managed building project. Meibes HIUs combine high quality components and reliability to deliver a peace of mind proposition which prevents expensive call backs.

Service

Pegler Yorkshire is committed to providing an after service experience that allows peace of mind for contractors and facility managers. A network of service teams is available with dedicated telephone support lines providing technical advice.

guaranteeon movingparts

2year

Page 7: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

7

ENERGY EFFICIENCY WITH IMPROVED SAP RATINGSCentralised heating systems are becoming increasingly popular for multi-residential properties as they offer a number of key advantages over decentralised systems with individual boilers in each apartment. These include:

Improved energy effi ciency

11% improvement in SAP ratings (compared to decentralised systems)

No gas installation throughout the building

No fl ues in apartments

Ease of access to heating plant for maintenance

Simple integration of low carbon and renewable heat sources.

Energy-saving features of Meibes HIUs

Meibes HIUs operate on a ‘no demand-no fl ow’ basis, so that when there is no demand for heating or DHW the unit effectively goes into standby. The arrangement minimises the demand on the main network, reduces energy consumption and ensures the apartment is not over-heated.

The performance of the units is based on primary fl ow temperatures of 65°C, enabling use with low carbon heat sources such as heat pumps. The resulting low return water temperatures also help to maximise condensing when condensing boilers are used.

To help ensure minimum heat losses from the system, all pipework is pre-insulated to save energy and reduce onsite insulation work. For further energy savings an A-rated pump aligns water fl ows with heating demand to minimise pump energy consumption.

Page 8: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

8

Meibes HIUs deliver key benefi ts for all parties in the supply chain, from initial system design

through to everyday operation and maintenance. All backed by the expertise and support of

Pegler Yorkshire.

BENEFITS FOR SPECIFIERS AND DEVELOPERS Lower capital costs

Reduced installation time

Simpler design of heating systems

Simpler pipework systems

No hot water storage necessary

Improved energy effi ciency and SAP rating

Facilitates integration of different heat sources

All distribution at low pressure and temperature

Easier to gain planning consent.

BENEFITS FOR CONTRACTORS Ease of installation

Faster fi x times

Ability to separate fi rst and second fi x

Ease of access to components

Annual servicing requirement.

BENEFITS FOR FACILITIES/PROPERTY MANAGERS All plant in a single plant room

No need to enter apartments for routine maintenance

Reduced energy consumption

Heat metering for billing residents

Ease of renewables inclusion

Reduced carbon footprint

Reduced annual boiler servicing cost over individual boilers.

A TOTAL SUPPORT PACKAGE FORSPECIFIERS, CONTRACTORS AND FACILITIES MANAGERS

Page 9: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

9

CHOOSING THE BEST SYSTEM FOR YOUR APPLICATION

The Meibes HIU range includes a number of different models for different applications. Use the

fl ow chart below to select the most appropriate model for your project.

No. of bathrooms

No. of bathrooms

No. of bathrooms

Heating & DHW

Heating to be connected to

the supply (direct)

orSeparatedvia a heat exchanger (indirect)?

Direct Heating & DHW

Indirect Heating & DHW

Stored DHW requirement?

DHW requirement for shower/

bath?

One

Two

+Accessories

+Accessories

+Accessories

+Accessories

Meibes HIU

A1 RX

Heat Exchanger

Type of Emitter?

Meibes HIU

A2 RX

Meibes HIU

A2 RX

Radiator

Meibes HIU

A2 UX

Meibes HIU

A2 UX

Underfloor

CylinderMeibes

HIU A1 CX

Instantaneous DHW

requirement?

DHW requirement for shower/

bath?

One

Two

DHW requirement for shower/

bath?

One

Two

DHW requirement for shower/

bath?

One

Two

No. of bathrooms

Page 10: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

10

SYSTEM BENEFITS Reduces heat losses

Reduces pumped volume around primary circuit

Removes peak load issues

Protects against variation in fl ow and return rates between apartments

Separate heating circuit

Flexible temperature control

Low maintenance requirements.

HEAT INTERFACE

UNIT

RADIATOR/UNDERFLOOR

HEATING

CENTRAL HEAT

GENERATOR

(Primary heating separate to

apartment circuit)

Heating flowHeating returnPotable water

Primary flow

DHW flowPrimary return

Mains water

INDIRECT SYSTEM – A2 RX/A2 UXThe indirect system provides both indirect space heating and indirect DHW. The system uses twin heat exchange units to supply instantaneous DHW and space heating.

The Proportional Modulating Valve operates in the same way as a combi diverter valves. Whenever there is a call for DHW, the PM valve diverts the primary fl ow through the heat exchanger to generate DHW, using all available energy to support the DHW demand. Typically, this results in the heating circuit being closed for just a few minutes, having minimal impact on occupant comfort.

When the DHW demand has been satisfi ed the primary fl ow reverts to the space heating system.

The comprehensive Meibes HIU range ensures that these units can be used with a range of

different system confi gurations.

DIRECT SYSTEM – A1 RXThe direct confi guration delivers the primary heating direct to the apartment circuit, with indirect DHW.

SYSTEM BENEFITS Reduced cost

Less space required in apartment

Low maintenance requirements.HEAT

INTERFACE UNIT

HEAT EMITTER

(Primary heating direct to

apartment circuit)

Heating flowHeating returnPotable water

Primary flow

DHW flowPrimary return

Mains water

CENTRAL HEAT

GENERATOR

INDIRECT FOR CYLINDER SYSTEM – A1 CXWhen using a cylinder system the primary circuit is separate to the secondary circuit, so that hot water is supplied from the cylinder, ensuring hot water is always available. The system incorporates a zone valve which is controlled by standard controls such as a time clock and a room thermostat to switch off the unit when there is no demand, thereby reducing network load.

SYSTEM BENEFITS Simple design

Differential pressure control

Heat usage metered

Hot water reserve in apartment.

CENTRAL HEAT

GENERATOR

DHW CYLINDER

HEATINTERFACE

UNIT

HEAT EMITTER

(Using a cylinder system)

Heating flowHeating returnPotable water

Primary flow

DHW flowPrimary return

Mains water

CHOOSING THE BEST SYSTEM FOR YOUR APPLICATION

Page 11: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

11

A2 RX

A1 RX

A1 CX

A2 UX

Page 12: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

12

PRODUCT FOCUS

Strainer – protects from system debris and prolongs life

Strainer – protects from system debris and prolongs life

Blending valve

Differential Pressure Control Valve – improved control, performance and installation

Heat exchanger (IH)

Pump – A-rated pump ensures efficient performance

Proportional Modulation Valve – gives priority to heating over DHW

Heat exchanger (DHW) – provides highly efficient performance from a compact unit

Primary return

Primary flow

Cold water mains DHW

Heating flow

Heating return

A2 RX HIU

Page 13: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

13

FEATURES Heat meter measures the

differential between fl ow and return temperatures

MID approved factory fi tted ultrasonic heat meters

Conforms to EN1434-3;1997

RHI and OMS compliant

Common Mbus output into data extraction

10 year battery life

Permanent display (shown in kWh).

HEAT METERSMeibes HIUs can be factory-fi tted with optional heat meters, allowing for accurate, measurement of heat energy use in individual apartments. Use of factory-fi tted heat meters reduces onsite work and enables optimum use of skilled labour for more complex tasks. Factory-fi tted units are pressure tested before delivery to site.

Data from the heat meters can be collected manually or via a wired or wireless network. Pre-payment can also be incorporated.

FIX RAILSFirst fi x rails allow a faster installation that can be staged to align with progress on other parts of the project. For example, the fi rst fi x may be carried out in the early stages, with the HIUs themselves being installed later in the project schedule. This reduces the risk of onsite damage to the HIUs.

The fi rst fi x rail is secured to the wall in the appropriate position allowing all plumbing connections to be made, pressure tested, fl ushed and fi lled. Depending on the nature of the contract, this may also support staged billing for work carried out and products installed.

Primary Bypass Module

First fix Rail (also available with Primary Bypass Module)

FEATURES WRAS approved ball valves

Factory sealed fl ow/return connections

Available with bypass for easy system fl ushing

Fix rail supports primary pipe work testing.

FEATURES Ability to consolidate

readings from up to 400 meters

Allows data extraction to be directly or remotely confi gured

Flexible programming allows meter readings to be time defi ned

Data can be retrieved or sent automatically via email as CSV-fi le or xml-fi le

SD card as back-up to prevent risk of data loss.

DATA EXTRACTIONThe most popular form of data extraction from heat meters is an Mbus network connection, which can be pre-fi tted to the heat meter. The data extraction unit sends a master signal to slave meters, which then report on energy consumption data. The readings can be sent via email or pulled directly from the data logger.

Where required, heat meters can be fi tted with radio-based data extraction systems.

Available May 2014

Page 14: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

14

PRODUCT DETAILS

MEIBES HIU INDIRECT UNIT

A2 RX BLU-CLIMATE RANGE

Page 15: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

15

MEIBES HIUA2 RX BLU-CLIMATE RANGE

The A2 RX is a higher capacity version of the A1 RX, suitable for apartments with two bathrooms.

FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Indirect Heating

Compact design – 500mm wide

Available in 15 and 19 litres per minute of DHW

HIU enables secondary heating for radiators

High specifi cation Differential Pressure Control Valve

Unique trickle bypass to enable unit primed for DHW

Available with case with window for viewing heat meter

Also available without case for fi tting within an existing cabinet

First fi x rails and bypass option also available

Complete with WRAS approved ball valves

Top connections for easy contractor access.

A2 RX Blu-Climate HIU range options

HIU model With box With heat meter Code

Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM Yes Yes 687900

Meibes A2 RX Blu-Climate HIU 15 IDH & HW Yes No 687901

Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM B No Yes 687902

Meibes A2 RX Blu-Climate HIU 15 IDH & HW B No No 687903

Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM Yes Yes 687904

Meibes A2 RX Blu-Climate HIU 19 IDH & HW Yes No 687905

Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM B No Yes 687906

Meibes A2 RX Blu-Climate HIU 19 IDH & HW B No No 687907

A2 RX Blu-Climate HIU accessory options

Accessory Code

Meibes A2 RX Fix Rail 687550

Meibes A2 RX Fix Rail TP 687551

687902/687906

Page 16: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

16

PRODUCT DETAILS

MEIBES HIU TECHNICAL & PERFORMANCE DATA& PERFORMANCE DATA& O C

A2 RX BLU-CLIMATE RANGE

A2 RX Blu-Climate HIU

Technical data

Description

TypeHeat Interface Unit for indirect heating and

instantaneous domestic hot water

Mounting Wall mounted

Size (WxDxH, height of the case) 500 x 350 x 750mm

Heating system 2 pipe flow

Construction

Pipework Fully insulated flexible stainless steel with brass fittings

Plates heat exchanger Stainless steel (heat exchanger space heating fully insulated)

Casing White powder coated sheet steel cover

Primary fluid Low pressure hot water

Secondary fluid – heating Low pressure hot water

Secondary fluid – domestic hot water Potable hot water service

Duty (primary) domestic hot water mode

Heat transfer capacity 42kW 50kW

Flow rate 0.275 l/s (990 l/h) 0.282 l/s (1,014 l/h)

Minimum flow temperature primary 65ºC 65ºC

Duty (secondary) domestic hot water

Heat transfer capacity 42kW @ 40K ΔT 50kW @ 40K ΔT

Flow rate 15 l/min (0.250 l/s) 19 l/min (0.317 l/s)

Fluid temperature in 10ºC 10ºC

Fluid temperature out 50ºC 50ºC

Blending valve 35-65ºC 35-65ºC

Duty (secondary) heating

Capacity 20kW max. @ 20K ΔT 20kW max. @ 20K ΔT

Fluid temperature flow 60ºC @ 65ºC primary flow 60ºC @ 65ºC primary flow

Fluid temperature return 40ºC 40ºC

Pressure

Maximum primary pressure 10bar 10bar

Maximum secondary pressure 3bar 3bar

Minimum supply water pressure 2bar, maximum 4bar 2bar, maximum 4bar

Connections All external connections ¾" ¾"

Fittings – primary and

secondary heating

Secondary circulation pump Wilo ‘A rated’ pump in secondary flow

Expansion vessel 8 litre fitted in secondary flow

Strainer On primary flow and secondary return

Sensor pockets Flow for heat meter

Heat meter Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display

Differential Pressure Control Valve (DPCV)

Factory set at 30kPa (maximum differential pressure 250kPa)

Primary bypass/trickle bypass Thermostatic bypass between primary flow and return

Air vents Manual

Controls Not pre-fitted – externally mounted single channel time switch + roomstat

Fittings – secondary domestic

hot water serviceControls Proportional modulation controlled

Page 17: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

17

Dimensions and clearances

Flow performance

Hydraulic layout

500mm 350mm

750mm

M P

W

1

3

4

5

8

2

16

6

15

Return Flow Cold water mains Domestic hot/cold water DHW Flow Return

Primary side Secondary side

7

10

11

1213 14

3

9

2

Key1 First fix Rail with connection ball valves (not illustrated)2 Strainer3 Provision for test points (½" connection)4 Heat meter5 Differential Pressure Control Valve (DPCV)6 Proportional Modulation Valve (PMV)7 Plate heat exchanger, DHW8 Thermostatic blending valve9 Drain point10 Thermostatic circulation valve (trickle bypass)11 Zone valve. Primary side space heating circuit12 Plate heat exchanger. Space heating13 Pressure gauge, secondary side14 Over pressure relief valve, secondary side15 Expansion vessel16 Circulator pump, secondary side

15L of DHW @ 60ºC

15L of DHW @ 50ºC15L of DHW @ 45ºC

Primary flow rate l/h*

Pri

mar

y flo

w d

egre

es º

C

0

10

20

30

40

50

60

70

80

90

100

0 500 1000 1500 2000 2500 3000 3500

*The primary flow should not exceed 1,000 l/h

36.43kW/cold water 10ºC

41.61kW/cold water 10ºC

51.92kW/cold water 10ºC

19L of DHW @ 45ºC

19L of DHW @ 60ºC

19L of DHW @ 50ºC

0

10

20

30

40

50

60

70

80

90

100

0 500 1000 1500 2000 2500 3000 3500

*The primary flow should not exceed 1,000 l/h

46.15kW/cold water 10ºC

52.70kW/cold water 10ºC

64.76kW/cold water 10ºC

Pri

mar

y flo

w d

egre

es º

C

Primary flow rate l/h*

Page 18: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

18

PRODUCT DETAILS

MEIBES HIU INDIRECT UNIT

A2 UX BLU-CLIMATE RANGE

Page 19: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

19

MEIBES HIU A2 UX BLU-CLIMATE RANGE

A2 UX models have been specifi cally designed for use with underfl oor heating.

FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Indirect Heating

Compact design – 500mm wide

Available in 19 litres per minute of DHW

HIU enables secondary heating for underfl oor heating

Integrated thermix module

High specifi cation Differential Pressure Control Valve

Unique trickle bypass to enable unit primed for DHW

Available with case with window for viewing heat meter

Also available without case for fi tting within an existing cabinet

Complete with fi x rails

Bypass option also available

Complete with WRAS approved ball valves

Top connections for easy contractor access.

A2 UX Blu-Climate HIU range options

HIU model With box With heat meter Code

Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM Yes Yes 687930

Meibes A2 UX Blu-Climate HIU 19 IDH & HW Yes No 687931

Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM B No Yes 687932

Meibes A2 UX Blu-Climate HIU 19 IDH & HW B No No 687933

A2 UX Blu-Climate HIU accessory options

Accessory Code

Meibes A2 RX Fix Rail 687550

Meibes A2 RX Fix Rail TP 687551

687932

Available May 2014

Page 20: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

20

PRODUCT DETAILS

MEIBES HIU TECHNICAL & PERFORMANCE DATA& PERFORMANCE DATA& O C

A2 UX BLU-CLIMATE RANGE

A2 UX Blu-Climate HIU

Technical data

Description

TypeDistrict heating station for indirect heating and

instantaneous domestic hot water

Mounting Wall mounted

Size (WxDxH, height of the case) 500 x 350 x 750mm

Heating system 2 pipe flow

Construction

Pipework Fully insulated flexible stainless steel with brass fittings

Plates heat exchanger Stainless steel (heat exchanger space heating fully insulated)

Casing White powder coated sheet steel cover

Primary fluid Low pressure hot water

Secondary fluid – heating Low pressure hot water

Secondary fluid – domestic hot water Potable hot water service

Duty (primary) domestic

hot water mode

Heat transfer capacity 50kW

Flow rate 0.282 l/s (1,014 l/h)

Minimum flow temperature primary 65ºC

Duty (secondary) domestic hot water

Heat transfer capacity 50kW @ 40K ΔT

Flow rate 19 l/min (0.317 l/s)

Fluid temperature in 10ºC

Fluid temperature out 50ºC @ 65ºC primary flow temperature

Blending valve 35-65ºC

Duty (secondary)

heating

Capacity 20kW max. @ 20K ΔT

Fluid temperature flow 60ºC @ 65ºC primary flow

Fluid temperature return Max. 40ºC (depends on UFH settings)

Pressure

Maximum primary pressure 10bar

Maximum secondary pressure 3bar

Minimum supply water pressure 2bar

Maximum supply water pressure 4bar

Connections All external connections ¾"

Fittings – primary and

secondary heating

Secondary circulation pump‘Thermix’ underfloor heating module with Grundfos pump

and automatic mixer 20-80ºC

Expansion vessel 12 litre fitted in secondary flow

Strainer On primary flow and secondary return

Sensor pockets Flow for heat meter

Test points Binder style test points

Heat meter Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display

Differential Pressure Control Valve (DPCV)

Factory set at 30kPa (maximum differential pressure 250kPa)

Primary bypass/trickle bypass Thermostatic bypass between primary flow and return

Air vents Manual

Zone valveFitted with electrical actuator head,

max. differential pressure 100 kPa (kvs=1.85)

Controls Not pre-fitted – externally mounted single channel time switch + roomstat

Fittings – secondary domestic

hot water serviceControls Proportional modulation controlled

Page 21: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

21

Dimensions and clearances

Flow performance

Hydraulic layout

500mm 350mm

750mm

M P

W

1

3

4

5

82

16

6

15

Return FlowCold water

mains

Domestic hot/cold water

DHW Flow Return

Primary side Secondary side

7

10

11

1213 14

3

9

2

Key1 First fix rail with isolating ball valves2 Strainer3 Provision for test points (½" connection)4 Heat meter5 Differential Pressure Control Valve (DPCV)6 Proportional Modulation Valve (PMV)7 Plate heat exchanger, DHW8 Thermostatic blending valve9 Drain point10 Thermostatic circulation valve (trickle bypass)11 Zone valve. Primary side space heating circuit12 Plate heat exchanger. Space heating13 Pressure gauge, secondary side14 Over pressure relief valve, secondary side15 Expansion vessel16 Underfloor heating, module secondary side (inc. pump mixer)

15L of DHW @ 60ºC

15L of DHW @ 50ºC15L of DHW @ 45ºC

Primary flow rate l/h*

Pri

mar

y flo

w d

egre

es º

C

0

10

20

30

40

50

60

70

80

90

100

0 500 1000 1500 2000 2500 3000 3500

*The primary flow should not exceed 1,000 l/h

36.43kW/cold water 10ºC

41.61kW/cold water 10ºC

51.92kW/cold water 10ºC

19L of DHW @ 45ºC

19L of DHW @ 60ºC

19L of DHW @ 50ºC

0

10

20

30

40

50

60

70

80

90

100

0 500 1000 1500 2000 2500 3000 3500

*The primary flow should not exceed 1,000 l/h

46.15kW/cold water 10ºC

52.70kW/cold water 10ºC

64.76kW/cold water 10ºC

Pri

mar

y flo

w d

egre

es º

C

Primary flow rate l/h*

Page 22: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

22

PRODUCT DETAILS

MEIBES HIU DIRECT UNIT

A1 RX BLU-CLIMATE RANGE

Page 23: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

23

MEIBES HIUA1 RX BLU-CLIMATE RANGE

The A1 RX unit provides direct heating and instantaneous hot water.

FEATURES & BENEFITS Designed to provide instantaneous Domestic Hot Water and Direct Heating

Compact design – 600mm wide

Available in 17 litres per minute of DHW

HIU enables differential pressure controlled primary heating for radiators

Unique trickle bypass to enable unit primed for DHW

Includes heat meter (optional)

Also available without case for fi tting within an existing cabinet

Complete with fi x rails and connectors for top connection

Complete with WRAS approved ball valves.

A1 RX Blu-Climate HIU range options

HIU model With box With heat meter Code

Meibes A1 RX Blu-Climate HIU 17 DH & HW HM Yes Yes 687950

Meibes A1 RX Blu-Climate HIU 17 DH & HW Yes No 687951

Meibes A1 RX Blu-Climate HIU 17 DH & HW HM B No Yes 687952

Meibes A1 RX Blu-Climate HIU 17 DH & HW B No No 687953

A1 RX Blu-Climate HIU accessory options

Accessory Code

Meibes A1 RX Fix Rail (for bottom connection) 687570

Meibes A1 RX Fix Rail (for top connection) 687573

Meibes A1 RX Hose Flush 687571

Meibes A1 RX Water Meter 687572

Top connection Bottom connection

Page 24: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

24

PRODUCT DETAILS

MEIBES HIU TECHNICAL & PERFORMANCE DATA& PERFORMANCE DATA& O C

A1 RX Blu-Climate HIU

Technical data

Description

Type Apartment substation for direct and instantaneous domestic hot water

Mounting Wall mounted

Size (WxDxH, height of the case) 600 x 210 x 800mm

Heating system 2 pipe flow

Construction

Pipework Fully insulated flexible stainless steel with brass fittings

Plate heat exchanger Stainless steel heat exchanger for domestic hot water (non-insulated for fast cool down/insulated if optional sanitary circulation)

Casing White powder coated sheet steel cover

Heating fluid Low pressure hot water

Domestic hot water Potable hot water service

Duty (primary) domestic

hot water mode

Heat transfer capacity 46kW

Primary flow rate 910 l/h

Minimum flow temperature primary 65ºC

Duty (sanitary)

Flow rate 17 l/min

Flow limiter Internal choke disk at cold water inlet

Fluid temperature in 10ºC

Fluid temperature out 50ºC @ 65ºC primary flow temperature

Blending valve 35-65ºC

Duty (space heating) Capacity 10kW max. @ 20K ΔT

Pressure

Maximum primary pressure 6bar

Maximum supply water pressure 10bar

Optimal supply water pressure 2bar

Temperatures Maximum operating temperature 110ºC

Connections All external connections ¾"

Fittings – heating

Strainer (optional) In primary flow inlet and/or space heating return (not LogoComfort Basis 600 plus)

Sensor pockets Sensor pocket in primary flow for optional heat meter

Heat meter mounting 110mm spool piece in primary return flow

Heat meter (optional) Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display

Differential Pressure Control Valve (optional)

Mounted in primary flow. Factory set = 30kPa, maximum differential pressure = 250kPa

Primary bypass/trickle bypass Thermostatic bypass between primary flow and return (adjustable 45-65ºC)

Air vents Manual

Zone valve In space heating return flow for optional electric actuator head mounting kvs = 1.85

Heating control (optional) Externally mounted electronic room heating control

Fittings – domestic hot water service

Control Proportional flow control with priority switch

Water meter mounting (optional) 110mm spool piece in cold water inlet

Water meter (optional) Rossweiner water meter, M-Bus

Connection (optional) Second cold water outlet after water meter

Sanitary circulation (optional) Sanitary circulation pump Wilo Star-Z Nova (P max = 4.5W) and external time switch

A1 RX BLU-CLIMATE RANGE

Page 25: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

25

Dimensions and clearances Hydraulic layout

600mm 210mm

800mm

Flow performance

0

10

20

30

40

50

60

70

80

90

100

0 500 1000 1500 2000 2500 3000 3500

*The primary flow should not exceed 1,000 l/h

46.6kW/cold water 10ºC

53.2kW/cold water 10ºC

65.6kW/cold water 10ºC

Pri

mar

y flo

w d

egre

es º

C

Primary flow rate l/h*

17L of DHW @ 45ºC

17L of DHW @ 50ºC

17L of DHW @ 60ºC

M

21

5

4

Heatingflow

Heatingreturn

Primaryreturn

Potablewater

DHW Coldwatermains

Primaryflow

3

4

6

7

8

9

1010

11

12

13

Key1 Stainless steel plate heat exchanger2 Proportional Modulation Valve (PMV)3 Flow restrictor disc 17 l/min4 Bleed point5 Zone valve (space heating control unit – optional)6 Balancer or Differential Pressure Control Valve (DPCV) – optional7 Thermostatic circulation bridge 45...65ºC – optional8 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread)9 ½" blind plug – to be replaced by temp. sensor pocket for

flow sensor (heat meter)10 Strainer11 Isolating ball valve ¾" female connection – optional12 Male connection/thread spool piece for cold water meter

(L=110mm, 2 x ¾" outer thread) – optional13 Blending valve (thermostatic hot water mixing valve) – optional

Page 26: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

26

PRODUCT DETAILS

MEIBES HIU INDIRECT UNIT FOR UFH AND CYLINDERSFOR UFH AND CYLINDERSO U C S

A1 CX BLU-CLIMATE RANGE

Page 27: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

27

MEIBES HIUA1 CX BLU-CLIMATE RANGE

A1 CX units are for use with a separate hot water cylinder and have the capacity to serve

apartments with two bathrooms.

FEATURES & BENEFITS Designed to suit projects where stored water is preferred

Compatible with pre-plumbed unvented cylinders

Complete with heat meter

Available with case with window for viewing heat meter

Also available without case for fi tting within an existing cabinet

Includes high specifi cation Differential Pressure Control Valve

Top connections for easy contractor access

Flow and primary return test points included

Built-in strainer for unit.

687972 687974

A1 CX Blu-Climate HIU range options

HIU model With box With heat meter Code

Meibes A1 CX Blu-Climate HIU 20K DH & HW HM Yes Yes 687970

Meibes A1 CX Blu-Climate HIU 20K DH & HW Yes No 687971

Meibes A1 CX Blu-Climate HIU 20K DH & HW HM B No Yes 687972

Meibes A1 CX Blu-Climate HIU 20K DH & HW B No No 687974

A1 CX Blu-Climate HIU accessory options

Accessory Code

Meibes A1 CX Fix Rail 687424

Meibes A1 CX Fix Rail and Bypass 687485

Page 28: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

28

PRODUCT DETAILS

MEIBES HIU TECHNICAL & PERFORMANCE DATA& PERFORMANCE DATA& O C

A1 CX BLU-CLIMATE RANGE

A1 CX Blu-Climate HIU

Technical data

Description

TypeDistrict heating station to be installed in conjunction

with a pre-plumbed unvented cylinder

Mounting Wall mounted with top or bottom connections

Size (WxDxH, height of the case) 400 x 180 x 500mm

Heating system 2 pipe flow

Construction

Pipework Fully insulated flexible stainless steel with brass fittings

Plate heat exchanger Fully insulated stainless steel

CasingWhite powder coated sheet steel cover with viewing window for the heat meter

Primary fluid Low pressure hot water

Secondary fluid Low pressure hot water

Duty (primary)

Heat transfer capacity 20kW max. @ 30K ΔT (500 l/h)

Fluid temperature flow 65ºC @ 70ºC primary flow

Fluid temperature return 40ºC

PressureMaximum primary pressure 10bar

Maximum secondary pressure 3bar

Connections All external connections ¾" female ball valves 4x: optional ‘First fix rail’

Fittings – primary side

Strainer On primary flow

Test points Binder style test points

Sensor pocket Primary flow temperature sensor for heat meter

Heat meter Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display

Solenoid valve (optional) Not pre-fitted – fitted via removable spool piece

Differential Pressure Control Valve (DPCV)

Factory set at 30kPa (maximum differential pressure 250kPa)

Air vents Manual

Zone valveFitted with electrical actuator head

maximum differential pressure 100kPa (kvs=1.85)

Page 29: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

29

Dimensions and clearances Hydraulic layout

400mm 180mm

500mm

M

M W

ReturnReturn FlowFlow

Primary sideSecondary side

2

11

8888

3

94

5

76

Key1 Test points2 Strainer3 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread)4 Differential Pressure Control Valve (DPCV)5 Zone valve6 Plate heat exchanger7 Bleed points8 ¾" ball valves (not illustrated)9 Solenoid valve (optional)

Page 30: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

MEIBES HEAT INTERFACE UNITTECHNICAL GLOSSARY

30

Meibes heat interface unit

Features Benefits

Designed specifically for UK Designed to meet UK requirements to avoid installation and performance issues. Comprehensive spare stocks available in UK.

Top entry connections Top entry pipework facilitates pipework runs in ceiling voids for quicker, simpler and more cost effective connection.

First fix rail

Enables faster installation and facilitates staged installation to suit the project timetable and contractor’s schedule. Also allows earlier primary testing of the main heat network. The first fix rail allows all plumbing connections to be made, pressure tested, flushed and filled before installation of the main unit, thereby reducing risk of damage and supporting staged applications for payment where appropriate.

All pipework is pre-insulated Minimises heat loss for higher energy efficiency, while also improving end user comfort by preventing heat transfer to property during summer.

Integrated Differential Pressure Control Valve (DPCV)

Integrated DPCV make the system ‘self balancing’ and ensures each unit only draws as much energy/flow as it requires in conjunction with a Proportional Modulating Valve. Results in a simpler design with improved control and less noise.

Vertically mounted, un-insulated Domestic Hot Water heat exchanger (DHW)

Uninsulated vertical heat exchanger accelerates cooling of DHW heat exchanger through convection and thermal radiation, minimising limescale formation, maintaining high performance and extending life of units.

Proportional Modulating Valve (PMV)

Gives priority to DHW generation over space heating to ensure full DHW performance. Primary flow rates are matched to cold water input.

Carbon coated operating rod in PM valve, with ceramic disk

Carbon coating provides self lubricating operation, with ceramic disc removing limescale each time the valve operates to deliver a longer, trouble free, service life.

Indirect energy supply Separates main primary circuit from secondary circuits, ensuring issues in either do not impact on the other. Also provides clear demarcation where different contractors are used for primary and secondary circuit installation.

No demand – no flow With no demand for hot water or heating the unit is effectively on standby with no flow (see trickle bypass). Minimises demand on main network, reduces energy costs and avoids ‘overheating’ of space where unit is fitted.

‘A-rated’ pump The electronic pump is an ‘A-rated’ Wilo pump which delivers energy-savings due to only using the minimum amount of electricity.

Blending valve Controls maximum temperature of DHW from the heat exchanger at 60ºC. The blend valve allows the temperature to adjust from 60ºC down to 35ºC depending on the application requirement.

Trickle bypass (included)Ensures that the prime flow is hot when the unit is switched off, ensuring quicker response times for DHW demand and eliminating ‘cold legs’ in network where HIUs are some distance from the main network. Avoids need for bypasses on risers, thereby simplifying network design.

Performance based on lower primary flow temperatures – 65ºC

Ensures maximum performance with condensing boilers and supports use of low carbon heat sources (e.g. heat pumps) with lower primary flow temperatures.

Return temperature limited (RTL) valve

An optional RTL is available if required to allow the return temperature to be limited. This protects the boiler from excessive temperatures.

Optional factory fitted, heat meter

Allows accurate measurement of individual energy use. Pressure tested and fitted at factory, reducing on site labour and risk. Range of options to suit project requirements – ultrasonic or mechanical. M-Bus, radio, manual reading, prepayment.

Potable water circuit WRAS approved to meet UK requirements and compliant with European Drinking Water directive, in line with Pegler Yorkshire’s commitment to highest quality and safety.

Warranties 2 year warranty on the unit and moving parts such as pump (on selected units).

Designed for ease of servicing Ease of access to all components ensures annual servicing can be completed quickly and efficiently.

Reduced lifecycle costs Product quality and ease of servicing ensure minimal cost of ownership with sustained high efficiency and performance.

Flexible stainless steel pipework Reduces thermal expansion stresses for quieter operation during warm up and cool down. Easier future servicing due to flat face connections. In the unlikely event of a need for component replacement, flexible pipework makes re-connection easier.

Test points Allows confirmation of flow pressure and temperature.

Strainers on primary and secondary circuits

Help to capture debris from either circuit, thereby protecting heat exchangers and/or other components, as well as extending service life. Strainer cleaning is included in annual servicing.

Vertically mounted insulated heat exchanger for heating circuit

Ensures heating circuit heat exchanger remains at temperature without introducing ‘heat’ to the unit. Lack of cycling and appropriate water treatments ensure that limescaling is not an issue.

Simple, straightforward control wiring External control wiring is similar to a conventional combi boiler and therefore familiar to installers.

Page 31: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

31

Indirect system A2 RX/A2 UX

Direct systemA1 RX

Indirect for cylinder systemA1 CX

Page 32: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

32

MEIBES BLU-CLIMATE

A2 RX HIU

Indirect DHWIndirect SH

MEIBES BLU-CLIMATE

A2 UX HIU

Indirect DHWIndirect SH

MICRO CHP

BIOMASS

GAS

HEAT INTERFACE UNIT

HEAT INTERFACE UNIT

MEIBES BLU-CLIMATE

A1 RX HIU

Indirect DHWDirect SH

MEIBES BLU-CLIMATE

A1 CX HIU

Indirect DHWIndirect SH

HEAT INTERFACE UNIT

HEAT INTERFACE UNIT

DHWCYLINDER

DATAEXTRACTION

UNIT

Heating flowHeating returnPotable water

Primary flow

DHW flowPrimary return

Mains water

2

4

1

5 5

5 5

5 5

1

1

1

DISTRICT HEATING SYSTEMSCLIMATE CONTROL

Market-leading Cost effective Highly versatile

metal push-fi t

Exceptional performance press-fi t for the widest variety of applications.

Strong, reliable press-fi t with simple, heat-free installation

Connect with confi dence

1 2 3

Page 33: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

33

DHW flow

DHW flow

DHW flow

DHW flow

UNDERFLOOR HEATING CIRCUIT

HEAT EMITTER

HEAT EMITTER

HEAT EMITTER

5 5

5 5

5 5

3

6

6

6

6

6

6

6

6

6

6

6

6

Commission and system balancing that optimises building system performance

Energy-saving radiator valves that maximise comfort

Putting you in control

4 5 6 Elegantly designed,

exceptional quality taps and showers

Page 34: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

NOTES

34

Page 35: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

35

Page 36: SUPERIOR QUALITY HEAT INTERFACE UNITS€¦ · HIU products that are suitable when designing apartments with multiple bathrooms. These ensure reliable performance for individual use

UK ENQUIRIES

UK SALESFree Phone: 0800 156 0010Free Fax: 0808 156 1011Email: [email protected]

TECHNICAL HELPFree Phone: 0800 156 0050Free Fax: 0808 156 1012Email: [email protected]

BROCHURE HOTLINEFree Phone: 0800 156 0020Free Fax: 0808 156 1011Email: [email protected]

INTERNATIONAL ENQUIRIES

EXPORTTel: +44 (0) 1302 855 656Fax: +44 (0) 1302 730 513Email: [email protected]

Follow us on

Registered in England Company No. 00401507

All brand names and logo styles are registered trademarks. Maintaining a policy of continual product development, Pegler Yorkshire reservesthe right to change specifi cations, design andmaterials of products listed in this publication without prior notice

Pegler Yorkshire

HEAD OFFICE

Pegler Yorkshire Group LimitedSt. Catherine’s Avenue, Doncaster, South Yorkshire DN4 8DF, England

Tel: +44 (0) 844 243 4400Fax: +44 (0) 844 243 9870Email: [email protected]

www.pegleryorkshire.co.ukLIT.REF: 880153.03.14