ML2144 SeriesSURFACE MOUNT MEDICAL SERVICE PANELS

cl ipsal .com/cis

Page 2: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

Introduction 2

Contents

Fascias 11

Grids 9-10

Mounting Brackets 8

Enclosure Construction 6-7

AS/NZS 3003 Electrical Instal lations 5

PATIENT TREATMENT AREAS

ML2144 Series 4

THE ECONOMICAL ALTERNATIVE

Page 3: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

In tro duc t ion

Hospitals have undergone a dramatic trans for ma tion

in the past 20 years. The de vel op ment of less

intrusive medical techniques has meant that patient

re cov ery times have been greatly reduced. As a

result, day surgery clinics are now a fea ture of

almost all hospitals.

The hospital environment too, is now a less

intrusive one. No longer clinical and old, patient

accommodation today is often of hotel standard.

Although there is a greater reliance on hi-tech

support equipment, this is now designed to blend

into the surroundings, creating a more relaxed

environment for both patients and medical staff.

The Medilec Range of hospital equipment has

been designed to meet this growing demand for

hospital services and equipment that are attractive

and less in tim i dat ing.

Page 4: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series
Page 5: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

THE

EC

ON

OM

ICA

L A

LTE

RN

ATI

VE

ML2

144

Seri

es

MEETING THE HIGH STANDARDS

All the ML2144 Series electrical accessories comply with

the relevant Australian Standards for electrical safety (as

well as standards for patient treatment areas) including

AS/NZS 3003 - “Electrical installations: patient treatment

areas of hospitals and medical and dental practices”.

ML2144 SERIES

Now an impressive part of the Medilec range, the

ML2144 Series is a range of mounting brackets that

allow the Medilec ML2164 fl ush metal plate medical

service panels to fi t onto surface mounted joinery

(supplied by others). The resulting surface mounted

medical service panel system is an economical system

that allows the designer to develop whatever joinery

profi le they require.

The ML2144 Series mounting brackets along with the

Medilec ML2164 fl ush mount medical service panels

incorporate the modular Medilec ML2000 and Clipsal

2000 range of electrical accessories, as well as the

various OEM products based on the Clipsal 2000 format,

which include nurse call systems and gas outlets etc.

4

Features & Benef i t s

Economical when compared to other surface mount

medical service panel systems.

Limitless joinery/enclosure designs due to the fl exibility

of using MDF or equivalent material.

Standard modular 1 to 4 gang fascias can butt together

either horizontally or vertically to produce special length/

height panels.

The ability to integrate the extensive range of modular

Medilec ML2000 and Clipsal 2000 Series accessories,

and OEM 2000 Series nurse call systems and gas outlets.

Grid mounted accessories allows for individual access to

each accessory.

A choice of fascia fi nishes and colours including natural

high grade stainless steel and powdercoated fi nishes.

Surface mounted systems provide better acoustic and

fi re rating characteristics than a recessed system.

Surface mounted systems provide less wall preparation

than a recessed system, which can interfere with internal

wall studs, especially if long panels are required.

Surface mounted systems provide an easy means to

cover existing wall cavities in retro fi t installations,

especially if walls are of brick construction.

Page 6: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

5

Pa

tien

t trea

tme

nt a

rea

sE

LE

CT

RIC

AL

INS

TA

LL

AT

ION

S

A S / NZS 3003 : ELEC TRIC AL INSTALL ATIONS -

PATIENT TREATMENT AREAS OF HOSPITALS AND

MEDIC AL AND DENTAL PR AC TICES

The ML2144 Series product range is designed to meet

the requirements of AS/NZS 3003. AS/NZS 3003 sets out

the specialist electrical installation requirements often

found in the following premises.

Hospitals

Medical Practices

Dental Practices

Physiotherapy Practices

The areas within these premises that would need to

meet AS/NZS 3003 are classifi ed as Body or Cardiac

Protected Areas. The procedures carried out to classify

these areas as Body or Cardiac Protected are as follows:

Within Body Protected Areas procedures are carried

out where a patient is connected to an item of

electromedical equipment which reduces the impedance

of the skin by either electrode paste or by the entrance

of conducting fl uids, metal needles, saline fi lled

catheters etc.

Within Cardiac Protected Areas the same procedures

are carried out as in the Body Protected Areas but also

procedures where a patient has an electrical conductor

placed within the heart or is likely to come in contact

with the heard eg. electrical wires such as cardiac pacing

electrodes and intracardiac ECG electrodes, or insulated

tubes fi lled with conducting fl uids.

Page 7: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

EN

CLO

SUR

E C

ON

STR

UC

TIO

NM

L214

4 Se

ries

BRACKET CUT-OUT

ML2144/1 120mm(H) x 103mm(W)

ML2144/2 120mm(H) x 175mm(W)

ML2144/3 120mm(H) x 247mm(W)

ML2144/4 120mm(H) x 319mm(W)

Tolerance : +/- 2mm

6

A

C

B

ENCLOSURE CONSTRUC TION

The surface mount joinery (supplied by others) enables the

architect limitless enclosure designs due to the fl exibility of

using MDF or an equivalent material. For instance individual

panels can be mounted end to end on a long length of

horizontal joinery or they can be mounted top to bottom

on vertical joinery.

Architects and joinery manufactures must follow these

simple guidelines when designing and manufacturing

the MDF enclosure, which are:

Enclosure dimensions:

a. MDF Material Thickness - 18mm (min)

b. Enclosure Height (internal) - 155mm (min)

c. Enclosure Depth - 55mm (min)

There are two exceptions to these limitations, which are:

If wiring and gas piping are to run within the

enclosure rather than the wall, then the height

and depth dimensions will need to increase.

The depth will reduce if an alternative semi recessed

enclosure is used that consists of only the 18mm

(min) MDF panel mounted directly to the wall

surface. The accessories being semi recessed into

the wall.

Prior to the enclosure being mounted to the wall the

ML2144 mounting brackets will need to be screwed to

the rear of the enclosure. Refer to the following points

for correct installation.

Standard 1 to 4 gang fascias can either be butted

together or spaced apart to produce special length

fascias. If they are required to be butted together

then simply butt together the corresponding

ML2144 mounting brackets, as they are the same

size as the fascia.

Prior to the brackets being installed onto the

enclosure each bracket will require a cut out in the

enclosure for the grid assembly to fi t within (refer

to table). A handy feature incorporated into the

mounting bracket design is the central cut out. It is

the same dimension as the grid that will be mounted

to the bracket therefore it can be used as a guide to

make sure the enclosure cut out is of adequate size.

Page 8: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

ML2

144 SeriesE

NC

LOSU

RE

CO

NSTR

UC

TION

7

ML2144

ML2144

ML2144

Page 9: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

8

MO

UN

TIN

G B

RA

CK

ETS

ML2

144

Seri

es

MOUNTING BRACKETS

Features

The 1 to 4 gang brackets are the same size as the

corresponding fascias. Brackets can quickly and

easily be butted together horizontally or vertically

which in turn butts together the fascias to produce

special length/height panels.

The central cut of the bracket is the same dimension

as the grid that will be mounted to it therefore the

cut-out can be used as a guide to make sure the

enclosure cut-out is of adequate size to allow the

grid to fi t.

ML2144/1

ML2144/3

ML2144/2

ML2144/4

ML2144/1 1 gang mounting bracket 150mm(H) x 135.5mm(W).

ML2144/2 2 gang mounting bracket 150mm(H) x 207.5mm(W).

ML2144/3 3 gang mounting bracket 150mm(H) x 279.5mm(W).

ML2144/4 4 gang mounting bracket 150mm(H) x 351.5mm(W).

CATALOGUE NUMBER DESCRIPTION

Page 10: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

Features

Adjustable grid height to allow easy positioning of

accessories fl ush with the wall surface.

Provision for mounting segregation between gangs.

Electrical accessories mounted on 72mm centres.

Gas outlets mounted on 108mm centres.

Accommodates all Medilec ML2000 and Clipsal 2000

accessories, and OEM 2000 Series nurse call systems

and gas outlets.

ML2164/1G ML2164/2G

ML2164/3G

ML2164/4G

ML2164/3G2

ML2164/2G2

GRIDS

GAS - 2000 SERIES

9

ML2

164 SeriesG

RID

S

ML2164/1G 1 gang grid 117mm(H) x 100mm(W) x 12mm(D).

ML2164/2G 2 gang grid 117mm(H)

x 172mm(W) x 12mm(D). ML2164/3G 3 gang grid 117mm(H)

x 244mm(W) x 12mm(D). ML2164/4G 4 gang grid 117mm(H)

x 316mm(W) x 12mm(D).

CATALOGUE NUMBER DESCRIPTION

STANDARD

ML2164/2G2 2 gang 2000 series gas grid 117mm(H) x 244mm(W) x 12mm(D). Suits 3 gang bracket.

ML2164/3G2 3 gang 2000 series

gas grid 117mm(H) x 316mm(W) x 12mm(D). Suits 4 gang bracket.

CATALOGUE NUMBER DESCRIPTION

Page 11: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

GR

IDS

ML2

164

Seri

es

10

Features

Adjustable grid height to allow easy positioning of the

EP Junction fl ush with the wall surface.

1 x BP25 Line tap for bus termination.

4 x 8mm and 10 x 5mm diameter termination tunnels.

1 x EP Earth stud.

EQUIPOTENTIAL JUNCTION

The Equipotential (EP) Junction is part of the EP Earthing

System (detailed in AS/NZS 3003) that is used to protect

against micro shock in Cardiac Protected Areas. The

EP Earthing system decreases the resistance/potential

differences between various Earthed points within the

Cardiac protected area.

ML2164E35G Equipotential Junction grid assembly 117mm(H) x 244(W)mm x 60mm(D). Suits 3 gang bracket.

CATALOGUE NUMBER DESCRIPTION

ML2164E35G

Page 12: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

11

ML2164/1F

Features

A choice of fascia fi nishes and colours including natural

high grade stainless steel and powdercoated fi nishes.

Electrical accessories mounted on 72mm centres.

Gas outlets mounted on 108mm centres.

Accommodates all Medilec ML2000 and Clipsal 2000

accessories, and OEM 2000 Series nurse call systems

and gas outlets.

Fascias

STANDARD

GAS - 2000 SERIES

ML2164/2F2 2 gang 2000 series gas fascia 150mm(H) x 280mm(W).

Suit 3 gang bracket. ML2164/3F2 3 gang 2000 series gas

fascia 150mm(H) x 352mm(W).

Suit 4 gang bracket.

CATALOGUE NUMBER DESCRIPTION

EQUIPOTENTIAL JUNCTION

ML2164E35F 1 gang EPJ fascia 150mm(H) x 280mm(W). Suit 3 gang bracket.

CATALOGUE NUMBER DESCRIPTION

ML2164/2F

ML2164/3F

ML2164/4F

ML2164/2F2

ML2164/3F2

ML2164E34F

ML2

164 SeriesFA

SCIA

S

ML2164/1F 1 gang fascia 150mm(H) x 135.5mm(W).

ML2164/2F 2 gang fascia

150mm(H) x 207.5mm(W). ML2164/3F 3 gang fascia

150mm(H) x 279.5mm(W). ML2164/4F 4 gang fascia

150mm(H) x 351.5mm(W).

CATALOGUE NUMBER DESCRIPTION

Page 13: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

NO

TES

ML2

144

Seri

es

NOTES

12

Page 14: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series
Page 15: Technical Information - Medilec ML2144 Series Surface Mount …updates.clipsal.com/clipsalonline/Files/Brochures/W... · 2009. 10. 23. · Technical Information - Medilec ML2144 Series

Products of Clipsal Integrated Sys tems Pty LtdA member of Clipsal Australia Holdings GroupABN 15 089 444 931

Head Offi ce12 Park Terrace, BowdenSouth Australia 5007PO Box 103 HindmarshSouth Australia 5007

Telephone (08) 8440 0500International +61 8 8440 0500

Facsimile (08) 8346 0845International +61 8 8346 0845

Internet www.clipsal.com/cisE-Mail [email protected]

CIS Technical Support Hotline1300 722 247

Offi ces in all States

NSW Sydney (02) 9794 9200 Albury (02) 6041 2377

VIC Melbourne (03) 9207 3200 Country Areas 1800 653 893

QLD Brisbane (07) 3244 7444 Townsville (07) 4729 3333

SA Adelaide (08) 8268 0400

WA Perth (08) 9442 4444

TAS Launceston (03) 6343 5900

NT Darwin (08) 8947 0278

International Enquiries

Head Offi ce Export DepartmentTelephone +61 8 8269 0587Facsimile +61 8 8340 7350E-Mail [email protected]

New ZealandClipsal Industries (NZ) Ltd (Auckland)Telephone +64 9 576 3403Facsimile +64 9 576 1015E-Mail headoffi [email protected] ServiceFree Facsimile (0508) 250 305Auckland/Mobile Phone (09) 572 0014Free Phone (0508) CLIPSAL 2547725

MalaysiaClipsal Malaysia Sdn BhdLot 26, Jalan Pengapit 15/19Shah Alam Industrial Estate40000 Sham Alam, Selangor Darul EhsanWest Malaysia, MalaysiaTelephone +60 3 5519 1111Facsimile +60 3 5519 4378

SingaporeClipsal SingaporeNo. 5, Fourth Chin Bee RoadSingapore 619699Telephone +65 6 415 3288Facsimile +65 6 415 3289E-Mail [email protected]

International Representatives

ChinaClipsal China Ltd Telephone +86 755 246 1122

Hong KongClipsal Integrated Systems (HK) Limited Telephone +852 2 487 0261

South AfricaClipsal South Africa (Pty) Ltd Telephone +27 11 314 5200

TaiwanClipsal (Taiwan) Co Ltd Telephone +886 2 2558 3456

ThailandClipsal Thailand Ltd Telephone +66 2 952 5338

United KingdomClipsal Ltd (UK) Telephone +44 1628 508 530

O/N 7175 March 04/01

Clipsal Integrated Systems Pty Ltd reserves the right to change spec i fi ca tions, modify designs and dis con tin ue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifi cations and other in for ma tion in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

clipsal.com/cis

You can fi nd this brochure and many others online in PDF format at: clipsal.comFollow the links off the home page or access the following page directly: clipsal.com/wat_lib_pdf.cfm

©Copyright Clipsal Integrated Systems Pty Ltd 2004.All right reserved.

This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Clipsal Integrated Systems Pty Ltd.