telewell vdsl2 toistin / pikaohje · pdf filestep 5. connect the single pair of telephone...

8
TeleWell VDSL2 TOISTIN / PIKAOHJE copyright © TeleWell Oy Myyntipaketin sisältö TeleWell VDSL2 Toistin Muuntaja (syöttää virran etänä) RJ-11 jakaja Virtajohto Pikaohje Laitteen tekniset merkinnät Etupuoli Merkkivalot Liittimet

Upload: vandat

Post on 07-Mar-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

TeleWell VDSL2 TOISTIN / PIKAOHJE copyright © TeleWell Oy

Myyntipaketin sisältö TeleWell VDSL2 Toistin Muuntaja (syöttää virran etänä) RJ-11 jakaja Virtajohto Pikaohje

Laitteen tekniset merkinnät

Etupuoli       Merkkivalot              

Liittimet

Page 2: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

Laitteiden kytkennät

Laitteen käyttöönotto Vaihe 1.

Asiakaspäässä muuntajaan kytketään kiinni virtajohto sekä RJ-11 jakaja

Vaihe 2.

Yhdistetään VDSL2 CPE-päätelaitteen Line-portista johto RJ-11 jakajan jompaan kumpaan porttiin

Vaihe 3.

Yhdistetään olemassa oleva DSLAM-yhteys (CO) RJ-11 jakajan toiseen porttiin

Vaihe 4. Optimaalisen tuloksen aikaansaamiseksi paikannetaan tilaajapään ja keskuspään keskikohta. Aseta TW-VDSL2-toistin mahdollisimman lähelle keskikohtaa

Page 3: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

Vaihe 5. Yhdistetään yksi puhelinjohtopari CO-linkistä TW-VDSL2 toistimen “CO LINE” –liittimeen

Vaihe 6.

Yhdistetään yksi puhelinjohtopari CPE-linkistä TW-VDSL2 toistimen “CPE LINE” –liittimeen

Vaihe 7. Odota 3-5 minuuttia kunnes yhteys on muodostunut laitteiden välille Yhteystiedot http://www.telewell.fi

Page 4: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

TeleWell VDSL2 REPEATER / QUICK START GUIDE copyright © TeleWell Oy

Package Contents TeleWell VDSL2 Repeater (2-Channel) Remote power feeding RJ-11 Splitter Power cord Quick Start Guide

Hardware Overview The  front  outlook   The  LEDs              

The connectors

Page 5: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

Hardware Connection

Hardware Installation Step 1.

At the customer site, connect the enclosed power cord and splitter to RJ-11 port of the Remote Power Feeder

Step 2.

Connect the WAN port of a VDSL2 CPE to either one of the two RJ-11 ports on the splitter

Step 3.

Connect the existing DSLAM Link(CO) to the other RJ-11 port on the splitter

Step 4.

Locate the mid-point between the subscriber and central office for optimal result. Place the VDSL2 repeater as close as possible to the mid-point within the total DSLAM to CPE loop.

Page 6: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

Step 5.

Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked “CO LINE”.

Step 6.

Connect the single pair of telephone grade UTP wire from the CPE link to terminal block connectors of the VDSL2 Repeater marked “CPE LINE”

Step 7.

Wait 3 to 5 minutes for the Repeater to establish stable connections between

DSLAM and CPE. Check the LED status on VDSL2 Repeater.

Contact http://www.telewell.fi

Page 7: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked

Declaration of Conformity

Page 8: TeleWell VDSL2 TOISTIN / PIKAOHJE · PDF fileStep 5. Connect the single pair of telephone grade UTP wire from DSLAM(CO) link to terminal block connectors of the VDSL2 Repeater marked