Temperature Distribution Flat Glass. Internal Furnace Inspections. Infrared Image . Visible Image . Colorized Image in Crude Oil Heater. Internal Furnace Inspections. Infrared Image . Visible Image . Colorized Image in Crude Oil Heater. Internal Furnace Inspections. Infrared Image . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Temperature Distribution Flat Glass

1

Temperature DistributionFlat Glass

Page 2: Temperature Distribution Flat Glass

2

Page 3: Temperature Distribution Flat Glass

3

Page 4: Temperature Distribution Flat Glass

4

Internal Furnace InspectionsVisible Image Infrared Image

Colorized Image in Crude Oil Heater

Page 5: Temperature Distribution Flat Glass

5

Internal Furnace InspectionsVisible Image Infrared Image

Colorized Image in Crude Oil Heater

Page 6: Temperature Distribution Flat Glass

Internal Furnace InspectionsVisible Image Infrared Image

Colorized Image in Husky Heater

Page 7: Temperature Distribution Flat Glass

Electrical Maintenance

• Maintenance: Much more than a “Necessary Evil”

• Most downtime is NOT inevitable• Prevent failures• Reduce both cost and time required for repair• Take control of your production and

profitability

Page 8: Temperature Distribution Flat Glass

Electrical Maintenance

Page 9: Temperature Distribution Flat Glass

Electrical Maintenance

Page 10: Temperature Distribution Flat Glass

Electrical Maintenance

Page 11: Temperature Distribution Flat Glass

Electrical Maintenance

Page 12: Temperature Distribution Flat Glass

Electrical Maintenance

Page 13: Temperature Distribution Flat Glass

Electrical Maintenance

Page 14: Temperature Distribution Flat Glass

Electrical Maintenance

Page 15: Temperature Distribution Flat Glass

Electrical Maintenance

Page 16: Temperature Distribution Flat Glass

Electrical Maintenance

Page 17: Temperature Distribution Flat Glass

Electrical Maintenance

Page 18: Temperature Distribution Flat Glass

Electrical Maintenance

Page 19: Temperature Distribution Flat Glass

Electrical Maintenance

Page 20: Temperature Distribution Flat Glass

Electrical Maintenance

Page 21: Temperature Distribution Flat Glass

Mechanical Maintenance

Infrared Image:

Bearing Load Strain/Wear

Reference Image:

Adjacent Pump

Page 22: Temperature Distribution Flat Glass

Mechanical Maintenance

Refractory Integrity

Page 23: Temperature Distribution Flat Glass

Mechanical Maintenance

Tempering Furnace Door

Page 24: Temperature Distribution Flat Glass

Mechanical Maintenance

Ladle Refractory

Page 25: Temperature Distribution Flat Glass

Roof Moisture Detection

Infrared Image:

Trapped Moisture in the Insulation

Photo:

Trapped Moisture in the Insulation

Page 26: Temperature Distribution Flat Glass

Infrared Imaging ApplicationsSummary

• Process/Quality Control • Research & Development• Electrical Maintenance• Mechanical Maintenance• Line Camera Speeds up to 18,000HZ.

Page 27: Temperature Distribution Flat Glass

Take Control of your Plant Efficiency!

• Control process temperatures to improve quality and reduce operating costs

• Develop and design better products with increased efficiency

• Prevent electrical and mechanical downtime

Page 28: Temperature Distribution Flat Glass

Elements of a Process Control System

  What is the target material? What is the target temperature?

Maximum and minimum temps! Is the target moving? At what speed? What is the target size? Is 1-5 frames per second adequate for

this application or do they need 30-60 frames per second?

Page 29: Temperature Distribution Flat Glass

Elements of a Process Control System

What is the perceived emissivity of the target? Are there different emissivity's on the target which need to be accounted for?

What accuracy of temperature measurement does the customer require?

What does the customer wish to do with the thermal data?

Page 30: Temperature Distribution Flat Glass

Elements of a Process Control System

In what form does the customer need the data? [i.e. digital/analog/4-20/etc]

Does the customer have some other software that needs to interface with our software?

What PLC does the customer use?

Page 31: Temperature Distribution Flat Glass

Elements of a Process Control System

Can the process tolerate ANY downtime? How much or little? Is a spare unit required? Do they require alarming if the unit goes down? Is a redundant system required?

Do they require/expect operational training on the system and/or software?

Page 32: Temperature Distribution Flat Glass

Elements of a Process Control System

Should you price in commissioning by a technician? [Two day minimum plus expenses]

When do they need the system installed and operational?

Page 33: Temperature Distribution Flat Glass

Elements of a Process Control System

How far away from the control room will the camera/s be installed? Do they want to use their own computer/processor? To eliminate problems it is firmly suggested that the vendor supply the processor fully configured and tested!

Page 34: Temperature Distribution Flat Glass

Elements of a Process Control System

How many cameras are necessary for the application? If one target…how much coverage they want will determine the number/s of cameras required!

Do they have Ethernet [100/GigE base T] available at the point of camera installation? If not, what do they have? Fiber optics ?

Page 35: Temperature Distribution Flat Glass

Elements of a Process Control System

Does the application require temperature measurement? This will determine if they need a computer with software or merely a video link!

Do they really have a need and will the total cost of installation provide a reasonable return on investment? Can this be illustrated/documented to the customer?