Test Report issued under the responsibility of:

TEST REPORT

IEC 60950-1 Information technology equipment – Safety –

Part 1: General requirements

Report Number. .............................. : 11038644 003

Date of issue ................................... : 2016-12-20

Total number of pages ................... : 10

Applicant’s name ............................ : Qisda Corporation

Address ........................................... : 157, Shan-Ying Road, Gueishan, Taoyuan 333 Taiwan

Test specification:

Standard .......................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

Test procedure................................ : CB Scheme

Non-standard test method ............. : N/A

Test Report Form No. ..................... : IEC60950_1F

Test Report Form(s) Originator ..... : SGS Fimko Ltd

Master TRF ...................................... : Dated 2014-02

Copyright © 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.

This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

General disclaimer:

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Page 4: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s
Page 5: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 3 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

List of Attachments (including a total number of pages in each attachment):

- Photo documentation

Total number of pages in each attachment is indicated in each individual attachment.

Summary of testing:

Tests performed (name of test and test clause):

All applicable tests as described in Test Case and Measurement Sections were performed.

• The manufacturer specified the maximum ambient temperature as +40°C.

• The load conditions used during testing as below: - video signal provided - full raster - maximum brightness and contrast - continuous operation - 0.9A load for each USB ports - 1kHz sine wave signal with maximum volume for speaks.

• As client’s request this equipment operating up to altitudes 5000m was considered, the required clearance multiplied by altitude correction factor 1.48 according to the Table A.2 of IEC 60664-1:1992 +A1:2000 +A2:2002 standard, see table 2.10.3 and 2.10.4.

• Test samples are pre-production samples without serial numbers.

Testing location:

All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 2.

Page 6: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 4 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

Summary of compliance with National Differences

List of countries addressed:

EU Group Differences, EU Special National Conditions, US.

Explanation of used codes: US = United States of America.

The product fulfils the requirements of EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013

EU Group Differences, EU Special National Conditions, CA, DE, FI, IL, KR, US.

Explanation of used codes: CA = Canada, DE = Germany, FI = Finland, IL = Israel, KR = Republic of Korea, US = United States of America.

The product fulfils the requirements of EN 60950-1:2006/A11:2009/A1:2010/A12:2011 For IEC 60950-1:2005 / EN 60950-1:2006+A11:2009 (per client request): AU Explanation of used codes: AU=Australia

For IEC 60950-1:2001 / EN 60950-1:2001+A11:2004 (per client request): (All CB members countries listed in CB Bulletin No. 112A, dated December 2006)

AR, AT, BE, CN, CZ, FR, GR, HU, IN, IT, JP, KE, MY, NL, PL, SG, SI, SK.

Explanation of used codes: AR=Argentina, AT=Austria, BE=Belgium, CN=China, CZ=Czech Republic, FR=France, GR=Greece, HU=Hungary, IN=India, IT=Italy, JP=Japan, KE=Kenya, MY=Malaysia, NL=The Netherlands, PL=Poland, SG=Singapore, SI=Slovenia, SK=Slovakia.

For IEC 60950:1999 (3rd Edition) + Corr. Jan. 2000 (per client request):

BR, IE, PT, RU, TR, UA, ZA.

Explanation of used codes: BR=Brazil, IE=Ireland, PT=Portugal, RU=Russian Federation, TR=Turkey, UA=Ukraine, ZA=South Africa.

Copy of marking plate

N/A

Page 7: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 5 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

Test item particulars ................................................... :

Equipment mobility .................................................. : [X] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in

Connection to the mains ......................................... : [X] pluggable equipment [X] type A [] type B [] permanent connection [X] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains

Operating condition ................................................. : [X] continuous [] rated operating / resting time:

Access location ....................................................... : [X] operator accessible [] restricted access location

Over voltage category (OVC) ................................. : [] OVC I [X] OVC II [] OVC III [] OVC IV [] other: not directly connected to the mains

Mains supply tolerance (%) or absolute mains supply values .......................................................... :

±10

Tested for IT power systems ................................. : [X] Yes [] No

IT testing, phase-phase voltage (V) ...................... : 230 for Norway

Class of equipment ................................................. : [X] Class I [] Class II [] Class III [] Not classified

Considered current rating of protective device as part of the building installation (A) ....................... :

16 (20 for North America)

Pollution degree (PD) ............................................. : [] PD 1 [X] PD 2 [] PD 3

IP protection class .................................................. : IPX0

Altitude during operation (m) ................................ : Up to 5000

Altitude of test laboratory (m) ................................ : Less than 2000

Mass of equipment (kg) .......................................... : Approx. 7.99 (including base 2.76kg)

Possible test case verdicts:

- test case does not apply to the test object ........... : N/A

- test object does meet the requirement .................. : P (Pass)

- test object does not meet the requirement ........... : F (Fail)

Testing .......................................................................... :

Date of receipt of test item ......................................... : 2016-12-08

Date(s) of performance of tests ................................ : 2016-12-08 to 2016-12-15

General remarks:

"(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator.

Page 8: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 6 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided.................................................................:

Yes

Not applicable

When differences exist; they shall be identified in the General product information section.

Name and address of factory (ies) .......................... : 1. Qisda (Suzhou) Co., Ltd. No. 169 Zhujiang Road, New District, Suzhou, Jiangsu 215129, P.R. China

2. Qisda Corporation 157, Shan-Ying Road, Gueishan, Taoyuan 333, Taiwan

3. Qisda Mexicana S.A. De C.V. Calzada Venustiano Carranza No.88 Col. Plutarco Elias Calles 21376 Mexocali, B.C. Mexico C.P MEXICO

4. Qisda Optronics (Suzhou) Co., Ltd. No.169, Zhujiang Road, New District, Suzhou, Jiangsu 215129, P.R. China

General product information:

Description of change(s):

1. Alternative an interface board P/N 4H.2N201.A1X for type B.

2. Alternative one panel source.

For the above described change(s) the following was considered to be necessary:

Change Testing Comments

1.,2. • Input test For test result see appended tables, The input test results are not greater than original tested, therefore no heating test considered as necessary

For source details see appended table 1.5.1.and see photo documentation.

Definition of variable(s):

Variable: Range of variable: Content:

* may be any alphanumeric character, symbol or blank

For marketing purpose only.

History of amendments and modifications:

Ref. No. 11038644 001, dated 2014-10-15 (original test report) Ref. No. 11038644 002, dated 2014-11-14 (modification) Ref. No. 11038644 003, dated 2016-12-20 (modification)

Page 9: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 7 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

Abbreviations used in the report:

- normal conditions N.C. - single fault conditions S.F.C - functional insulation OP - basic insulation BI - double insulation DI - supplementary insulation SI - between parts of opposite polarity BOP - reinforced insulation RI Indicate used abbreviations (if any)

Page 10: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 8 of 10 Report No. 11038644 003

IEC 60950-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60950_1F

1.5.1 TABLE: List of critical components P Object/part No. Manufacturer/

trademark Type/model Technical data Standard

(Edition / year) Mark(s) of

conformity1)

LCD AUO M270QAN**** 27.0” TFT LCD Panel module

-- --

Supplementary information:

1. Provided evidence ensures the agreed level of compliance. See OD-CB2039.

1.6.2 TABLE: Electrical data (in normal conditions) P

U (V/Hz) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status

Power supply board 4H.2N201.A1X

Signal from HDMI port

90/50 0.72 -- 64.8 F601 0.72 Maximum normal load.

90/60 0.72 -- 64.7 F601 0.72 Maximum normal load.

100/50 0.65 1.2 64.9 F601 0.65 Maximum normal load.

100/60 0.65 1.2 64.8 F601 0.65 Maximum normal load.

240/50 0.28 1.2 68.4 F601 0.28 Maximum normal load.

240/50 0.28 1.2 68.7 F601 0.28 Maximum normal load.

264/60 0.27 -- 70.4 F601 0.27 Maximum normal load.

264/60 0.27 -- 70.6 F601 0.27 Maximum normal load.

Signal from DVI port

90/50 0.72 -- 64.8 F601 0.72 Maximum normal load.

90/60 0.72 -- 64.6 F601 0.72 Maximum normal load.

100/50 0.65 1.2 64.9 F601 0.65 Maximum normal load.

100/60 0.65 1.2 64.8 F601 0.65 Maximum normal load.

240/50 0.28 1.2 68.2 F601 0.28 Maximum normal load.

240/50 0.28 1.2 68.7 F601 0.28 Maximum normal load.

264/60 0.27 -- 70.1 F601 0.27 Maximum normal load.

264/60 0.27 -- 70.5 F601 0.27 Maximum normal load.

Signal from VGA port

90/50 0.72 -- 64.5 F601 0.72 Maximum normal load.

90/60 0.72 -- 64.6 F601 0.72 Maximum normal load.

100/50 0.65 1.2 64.6 F601 0.65 Maximum normal load.

100/60 0.65 1.2 64.6 F601 0.65 Maximum normal load.

240/50 0.28 1.2 67.9 F601 0.28 Maximum normal load.

Page 11: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 9 of 10 Report No. 11038644 003

IEC 60950-1

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC60950_1F

240/50 0.28 1.2 68.4 F601 0.28 Maximum normal load.

264/60 0.27 -- 69.7 F601 0.27 Maximum normal load.

264/60 0.27 -- 70.3 F601 0.27 Maximum normal load.

Supplementary information:

1. See summary of testing in the test report for the detail max. normal condition.

2. The measured input current at rated voltage shall be ≤ 110 % of rated current.

Page 12: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

Page 10 of 10 Report No. 11038644 003

TRF No. IEC60950_1F

List of test equipment used: A completed list of used test equipment shall be provided in the Test Reports when a Manufacturer Testing Laboratory according to TMP/CTF stage 1 or WMT/CTF stage 2 procedure has been used.

Clause Measurement / testing

Testing / measuring equipment / material used

Range used Calibration date

Information: This list is only required for RMT, SMT, TMP and WMT Testing Procedures. "No listing of test equipment used necessary for chosen test procedure".

Page 13: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

ATTACHMENT Photo Documentation

Page 1 of 2

Report No.: 11038644 003

Product: LCD Monitor

Type Designation: BL2711*** ( “ *” may be any alphanumeric character, symbol, or blank. ) (BenQ)

Rev. 0

For main board type B P/N 4H.2N201.A1X

Page 14: Test Report issued under the responsibility of...Jan 04, 2017  · The authenticity of this Test Report and its contents can be verified by contacting the NCB, ... • As client’s

ATTACHMENT Photo Documentation

Page 2 of 2

Report No.: 11038644 003

Product: LCD Monitor

Type Designation: BL2711*** ( “ *” may be any alphanumeric character, symbol, or blank. ) (BenQ)

Rev. 0