TEST REPORT No. : GZMR140100779 Date : Apr. 03, 2014 Page: 1 of 13 FOSHAN CHANCHENG XINGFA TILE INDUSTRY CO., LTD XINGFA BUILDING NANZHUANG ROAD CHANCHENG DISTRICT FOSHAN CITY GUANGDONG CHINA The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : SYNTHETIC RESIN ROOFING TILE Material : PVC Spec. : 150X70X3.0MM Manufacturer : FOSHAN CHANCHENG XINGFA TILE INDUSTRY CO., LTD SGS Ref No. : GP140100066-2.1, SDHG1401000735FB Test Performed : Selected test(s) as requested by applicant Date of Receipt : Jan. 15, 2014 Test Period : Jan. 15, 2014 to Mar. 03, 2014 Test result(s) : Please refer to the following page(s) ********To be continued******** Signed for and on behalf of SGS-CSTC Standards Technical Services Co.,Ltd Guangzhou Branch ____________________ Cathy Peng Technical Supervisor

Upload: others

Post on 29-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 1 of 13

FOSHAN CHANCHENG XINGFA TILE INDUSTRY CO., LTD

XINGFA BUILDING NANZHUANG ROAD CHANCHENG DISTRICT FOSHAN CITY GUANGDONG CHINA

The following sample(s) was/ were submitted and identified on behalf of the client as:

Sample Name : SYNTHETIC RESIN ROOFING TILE

Material : PVC

Spec. : 150X70X3.0MM

Manufacturer : FOSHAN CHANCHENG XINGFA TILE INDUSTRY CO., LTD

SGS Ref No. : GP140100066-2.1, SDHG1401000735FB

Test Performed : Selected test(s) as requested by applicant

Date of Receipt : Jan. 15, 2014

Test Period : Jan. 15, 2014 to Mar. 03, 2014

Test result(s) : Please refer to the following page(s)

********To be continued********

Signed for and on behalf of SGS-CSTC Standards Technical Services Co.,Ltd Guangzhou Branch

____________________ Cathy Peng Technical Supervisor

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 2 of 13

Test Information:

Sample description: See photo

No. Test item Test method Test condition Test result

1 Xenon-arc

Exposure

ISO 4892-2:2013, ISO

105-A02:1993

Cor2:2005 and ASTM

D2244-11

ISO 4892-2:2013 cycle 4

Irradiance: (0.51±

0.02)W/(m2·nm)@340nm

102 min light at (63±3)℃ BPT, (50

±10)% RH

18 min light and water spray

Filter: Boro/Boro

Exposure period: 500h

Grey scale

(See note 1) 2-3

∆E*ab

(See note 2) 3.5

2 Thermal

resistance

With reference to

ASTM D3045-

92(2010) and client’s

requirements

150℃, 30min

Visible deformation

and colour fading,

but no other visible

change.

3 Muriatic acid

resistance

With reference to ISO

175-2010 and client’s

requirements

Medium: 35%(m/m) HCl(AR)

Method: Immersion method

Temperature: Room temperature

Test time: 48h

No visible change.

4 Sulfuric acid

resistance

With reference to ISO

175-2010 and client’s

requirements

Medium: 30%(m/m) H2SO4(AR)

Method: Immersion method

Temperature: Room temperature

Test time: 48h

No visible change.

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 3 of 13

No. Test item Test method Test condition Test result

5 Alkali

resistance

With reference to ISO

175-2010 and client’s

requirements

Medium: 40%(m/m) NaOH(AR)

Method: Immersion method

Temperature: Room temperature

Test time: 48h

No visible change.

6 Density ISO 1183-1:2012

Method A Absolute alcohol, 23±0.5℃ 1.799g/cm

3

7 Flexural

strength ISO

178:2010/Amd.1:2013

Method A

Specimen: 100×10.96×3.12mm

Testing speed: 1mm/min

Span: 50mm

41.3MPa

8 Flexural

modulus 4520MPa

9

Charpy

unnotched

impact

strength

ISO 179-1: 2010

Specimen: ISO 179-1/1eU

Specimen thickness: 3.13mm

The capacity of the pendulum:

5J

Impact speed: 2.90m/s

Span: 62mm

38kJ/m2

C(complete break)

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 4 of 13

No. Test item Test method Test condition Test result

10

Vicat

softening

temperature

ISO 306:2004 Method

B50

Specimen thickness: 3.01mm

Rate of temperature: 50℃/h

Load: 50N

77.3℃

11 Tensile

strength

ISO 527-1:2012 and ISO

527-2:2012

Specimen: Type 1B

Specimen thickness: 3.05mm

Testing speed: 5mm/min

Grip separation: 115mm

20.3MPa

12

Nominal

tensile strain

at break

13%

13 Impact

resistance

GB/T 8814-2004 Section

5.7 and 6.7

Precondition: -10℃, 1h→Take

out and do the test within 10s.

Specimen thickness: 3.02mm

Geometry: H.25

Strike weight: 1.0kg

Span: 200mm

Number of specimens tested: 10

Number of specimen

breakage: 0

14

Dimensional

change

(See note 3)

With reference to ASTM

D1204-08 and client’s

requirement

Condition: 100℃, 60min→

23±2℃, 50±5%RH, 1h

Specimen: 25×25cm

Medium: Talcum powder

X

direction -0.7%

Y

direction -1.3%

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 5 of 13

No. Test item Test method Test condition Test result

15 Oxygen Index

ISO 4589-1:1996 and

ISO 4589-2:

1996/Amd.1:2005

Specimen: Type Ⅲ

Specimen thickness: 3.2mm

Ignition procedure: Method A

32.8%

16 Horizontal

burning test UL 94-2013 Section 7

Specimen: 126×13.4×3.0mm

Conditioning:23±2℃,

50±5%RH, 48h

HB

(See table 1, 2 and

note 4)

17

20 mm

Vertical

burning test

UL 94-2013 Section 8 Specimen: 126×13.4×3.0mm V-1

(See table 3 and 4)

18 Burning test DIN 4102-1:1998-05 See appendix 1

The sample tested

met the requirements

of class B2

(See appendix 1)

Note: 1.According to ISO 105-A02, the grey scale was determined under the D65 standard light, scale 5 is the best

and scale 1 is the worst.

2.∆E*ab was measured by sphere spectrophotometer under D65 standard light source and with 10° observer. The

results include specular reflection condition, 8mm aperture.

3.Dimensional change, % = (Dimension after heating – Dimension before heating)/ Dimension before heating×100

4.The flame extinguished before the 25 mm mark.

5.All test specimens were cut from the sample.

6. Test item 18 was carried out by SGS internal laboratory.

Table 1

Specimen No. 1 2 3

Burning distance, mm / / /

Burning time, s / / /

Burning rate, mm/min 0 0 0

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 6 of 13

Table 2

HB Criteria classification

a) Not have a burning rate exceeding 40 mm per minute over 75 mm

span for specimens having a thickness of 3.0 to 13 mm, or

b) Not have a burning rate exceeding 75 mm per minute over 75 mm

span for specimens having a thickness less than 3.0 mm, or

c) Cease to burn before the 100 mm reference mark.

Table 3

Conditioning 23±2 , 50±5%RH, 48h℃ 70±2℃, 168h→

Desiccator, 23±2 , 4h℃

Specimen No. 1 2 3 4 5 1 2 3 4 5

Afterflame time after first flame

application (s), t1 0 0 0 0 0 0 0 0 0 0

Afterflame time after second flame

application (s), t2 1.0 1.5 4.8 2.3 1.1 13.8 12.5 14.8 12.9 13.8

Afterglow time after second

application (s),t3 1.0 0.8 1.0 0.4 0.4 1.0 1.5 1.4 1.1 1.3

Total afterflame time for any condition set

(s), t1+t2 10.7 67.8

Afterflame time plus afterglow time after

second flame application (s), t2+t3 2.0 2.3 5.8 2.7 1.5 14.8 14.0 16.2 14.0 15.1

Whether or not specimens burn up to the

holding clamp No No No No No No No No No No

Whether or not specimens drip flaming

particles and whether the particles ignited

the cotton indicator

No No No No No No No No No No

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 7 of 13

Table 4

Criteria conditions V-0 V-1 V-2

Afterflame time for each individual specimen t1 or

t2 ≤10s ≤30s ≤30s

Total afterflame time for any condition set

(t1+t2 for 5 specimens) ≤50s ≤250s ≤250s

Afterflame plus afterglow time for each individual

specimen after the second flame application

(t2+t3)

≤30s ≤60s ≤60s

Afterflame or afterglow of any specimen up to the

holding clamp No No No

Cotton indicator ignited by flaming particles or

drops No No Yes

Appendix 1:

Test Conducted:

These tests are conducted in DIN 4102-1 Clause 6.1 Class B1 materials according to the application.

I. Sample details:

Materials / Color PVC / Red

Thickness 3.0mm

II. Test Condition

Temperature Relative humidity Duration

Precondition T=(23±2)℃ (50±6)% 1 week

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 8 of 13

III. Test Requirement:

All materials, except flooring, may be classed as B1 materials if they

– withstand the test specified in DIN 4102-16 using the ‘Brandschacht’ apparatus specified in DIN 4102-15,

and

– meet the requirements for class B2 materials.

The test using the ‘Brandschacht’ apparatus described in DIN 4102-15 (cf. subclause 6.1.3.1) shall be

deemed passed if

– the mean value for the residual length (portion of specimen that has not burned or charred; cf. subclause

9.1 of DIN 4102-16) of each specimen is at least 15 cm and no individual values are lower than 0 cm,

– the mean effluent temperature does not exceed 200 °C in any test,

– the requirement for the residual length of each specimen is met even where there is afterflame, afterglow,

or smouldering.

IV. Test Results

The test results were obtained using the specified test conditions and do not necessarily represent the

behavior of the test material under other conditions of test or use.

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 9 of 13

①DIN 4102-1 B2 Test Result

Parameter

Result

Bottom edge ignition Surface ignition

1 2 3 4 5 6 7 8 9 10

Specimen ignition (Yes/No) Yes* Yes* Yes* Yes* Yes* No No No No No

Ignition ceased time(s) - - - - - - - - - -

If flame tip reached 150mm

line/40,190mm line(Yes/No) No No No No No No No No No No

Ignition time to reached

150mm line/40,190mm line(s) - - - - - - - - - -

Filter paper ignition (Yes/No) No No No No No No No No No No

Smoke developments (visual

impression) Slight Slight

Note: *--The specimen was ignited but self-extinguished after removed the burner.

Class B2 Test requirement:

This test shall be deemed passed if, for any of the five specimens tested, flaming does not reach the gauge

mark within 20 seconds after flame application, either with bottom edge ignition or surface ignition.

Sub-conclusion: Pass

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 10 of 13

② Additional DIN4102-16 Test Result

Group 1:

Parameter Result

1 2 3 4 Average value

Remaining length (cm) 0 0 0 0 0

Max. flue gas temperature 217℃

Max.flame high (cm) 170

After flame / after glow N/A

Other observation Charring

Group 2:

Parameter Result

1 2 3 4 Average value

Remaining length (cm) 0 0 0 0 0

Max. flue gas temperature 231℃

Max.flame high (cm) 172

After flame / after glow N/A

Other observation Charring

Group 3:

Parameter Result

1 2 3 4 Average value

Remaining length (cm) 0 0 0 0 0

Max. flue gas temperature 210℃

Max.flame high (cm) 163

After flame / after glow N/A

Other observation Charring

Note: N/A=Not Application

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 11 of 13

Sub-conclusion: Fail

Ⅴ. Conclusions

The sample tested met the requirements of class B2 of DIN 4102-1:1998-05.

Photo:

Reference sample Tested sample

Reference sample Tested sample

Xenon-arc Exposure Thermal resistance

Reference sample Tested sample

Reference sample Tested sample

Muriatic acid resistance Sulfuric acid resistance

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 12 of 13

Reference sample Tested sample

Alkali resistance

Sample for test item 6 Sample for test item 7, 8 and 9

Sample for test item 10 Sample for test item 11 and 12

********To be continued********

TEST REPORT

No. : GZMR140100779

Date : Apr. 03, 2014

Page: 13 of 13

Sample for test item 13 Sample for test item 14

Sample for test item 15 Sample for test item 16 and 17

Sample for test item 18

*******End of report********