tile tech pedestal

28
Paving America one step at a time! Tile Tech Pedestal ® HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS Uni-Just™ & Stak-Cap™ Pedestal System Single Model Design PVC Pipe Adjustable Self-Leveling Screw Adjustable Stackable Pat. # 8,453,391 & Pat. Pen

Upload: others

Post on 16-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Tile Tech Pedestal

Paving America one step at a time!Tile Tech Pedestal®

HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS

Uni-Just™ & Stak-Cap™ Pedestal System

Single Model Design PVC Pipe Adjustable Self-LevelingScrew Adjustable Stackable

Pat. # 8,453,391 & Pat. Pen

Page 2: Tile Tech Pedestal

TILE TECH PEDESTAL SYSTEMTABLE OF CONTENTS

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 2

3. COMPONENTS LIST

7. INSTALLATION INSTRUCTIONS UNI-JUST™ PEDESTALS

5. INSTALLATION INSTRUCTIONS STAK-CAP™ PEDESTALS

4. COMPONENT ASSEMBLY INSTRUCTIONS STAK-CAP™ PEDESTALS

6. COMPONENT ASSEMBLY INSTRUCTIONS UNI-JUST™ PEDESTALS

8. BASE SLOPE COMPENSATION

9. UNI-SHIM™ APPLICATION

10. PEDESTAL COMBINATION & CONFIGURATION

11. SAMPLE DECK LAYOUT - OVERVIEW

12. SAMPLE INITIAL INSTALLATION

13. THRESHOLD PEDESTAL APPLICATION

14. RADIUS PEDESTAL APPLICATION

16. DIAGONAL PERIMETER APPLICATION

17. LOW HEIGHT PEDESTAL APPLICATION

18. DRAIN PEDESTAL APPLICATION

20. PERIMETER EDGE RESTRAINT STEP-DOWN AND GREEN ROOF CONTAINMENT

19. PERIMETER EDGE RESTRAINT METAL FLASHING AND WOOD FASCIA CONTAINMENT

21. STEP-DOWN PEDESTAL APPLICATION

22. IPE WOOD TILE APPLICATION

23. WOOD TILES 20X20 DETAILS

24. WOOD TILES 24X24 DETAILS

25. JOIST DECK PEDESTAL APPLICATION

26. WIN-LOC™ PAVER PAVER LOCK DOWN SYSTEM FOR WIND UPLIFT.

27. HEX-TRAY™ PAVER SNOW MELT SYSTEM.

15. CORNER PEDESTAL APPLICATION

Paving America one step at a time!Tile Tech Inc.®

Page 3: Tile Tech Pedestal

TILE TECH PEDESTAL SYSTEMCOMPLETE PRODUCT LINE & COMPONENTS LIST

MODEL NUMBER DESCRIPTIONPRODUCT LINE

SPACERS 1/8” & 1/4”

UNI-SHIM™ - 1/8” & 1/16”

ALLOW FOR 1/8” SPACING GAP BETWEEN PAVERS FOR DRAINAGE. TABS A PERFORATED FOR EASY REMOVAL.

USED FOR FINE TUNING OF INDIVIDUAL PAVERS. CAN BE USED ON TOP OR BOTTOM OF PEDESTALS. CAN BE STACKED & BROKEN IN TO QUARTERS OR HALVES.

UNI-INSERT™ -75 (3/4”)USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 3/4” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.

BUFFER PAD

PROVIDES PROTECTION TO WATERPROOFING MEM-BRANE FROM WEAR AND PROVIDES SLIP RESISTANCE TO PEDESTAL. ATTACHES TO BOTTOM OF BASE. ALIGN PERIMETER NOTCHES WITH CHALK LINES.

UNI-COLLAR™

USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL SYSTEM. COMPRESSION FITS ON TO TOP END OF PVC PIPE.

SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE. ALIGN & LOCK TO UNI-INSERT™.

UNI-CAP™

STAK-CAP™USED OF LOW HEIGHT REQUIREMENTS. ROTATE AND STACK CAPS FOR SLOPE & HEIGHT ADJUSTMENT. CAN ALSO BE USED WITH PVC PIPE TO REACH 6” MAX.

UNI-BASE™

USED AS BASE OF PEDESTAL SYSTEM. COMPRESSION FITS ON TO END OF PVC PIPE. CAN ALSO BE USED WITH UNI-INSERT™ FOR LOW HEIGHT APPLICATIONS. LARGE SURFACE AREA PROVIDE ADDED STABILITY.

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

UNI-INSERT™ -150 (1-1/2”)

USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES-TAL. SCREWS IN TO UNI-COLLAR™. PROVIDES ADDI-TIONAL 1-1/2” OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE.

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 3

USED FOR SLOPE COMPENSATION AT BASE OF PEDESTALS. EACH PLATE COMPENSATES FOR 1/4” PER FOOT (2%) SLOPE AND ADDS 3/8” TO THE OVERALL HEIGHT OF PEDESTAL. MAXIMUM OF FOUR PLATES MAY BE STACKED FOR COMPEN-SATION OF UP TO 1” PER FOOT (0-8%) SLOPE.

BASE SLOPE PLATE (BSP)

Paving America one step at a time!Tile Tech Inc.®

Page 4: Tile Tech Pedestal

STAK-CAP™ PEDESTAL SYSTEM

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

CONFIGURATION CHART:1 CAP = 5/8” HIGH 1/8” PER FOOT 1% MAX2 CAPS = 1” HIGH 1/4” PER FOOT 2% MAX (A+A)3 CAPS = 1-3/8” HIGH 3/8” PER FOOT 3% MAX (A+A+A)4 CAPS = 1-7/8” HIGH 1/2” PER FOOT 4% MAX (A+A+A+A)5 CAPS = 2-1/4“ HIGH 5/8” PER FOOT 5% MAX (A+A+A+A+A)

PVC + 2 CAPS = VARIABLE HEIGHT 0% MAXPVC + 3 CAPS = VARIABLE HEIGHT 1% MAXPVC + 4 CAPS = VARIABLE HEIGHT 2% MAXPVC + 5 CAPS = VARIABLE HEIGHT 3% MAX

COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 1/2” TO 2-¼” & SLOPE ADJUSTMENT FROM 0% TO 5%

PRODUCT CHARACTERISTICS:EACH CAP WILL COMPENSATE FOR UP TO 1/8” PER FOOT SLOPE (1%) & ADD 3/8” TO THE OVERALL HEIGHT OF A PEDESTAL. PVC PIPE SHOULD NOT BE USED. ROTATE ONE CAP RELATIVE TO ANOTHER BY ALIGNING THE ALPHABETS TO CHANGE SLOPE. A & A WILL REACH MAXIMUM SLOPE AND A & E WILL CANCEL SLOPE. A MAXIMUM OF 5 CAPS CAN BE STACKED WITH TOTAL SLOPE OF 5/8” PER FOOT (5%) & WITH TOTAL HEIGHT OF 2-¼” INCLUDING THE USE OF BUFFER PADS.

STACK

ROTATE

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 4

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 5: Tile Tech Pedestal

STAK-CAP™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS - 1/2” to 2-¼” HIGH & 0%-5% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

9. For IPE wood insert the lock washer in to the kurf-cut on the corners of wood tiles then insert screw through lock washer and hand tighten.

1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.

8. Use a spirit level to check level and use additional half or quarter Uni-Shims™ for fine tuning of individual corners of pavers.

7. Adjust final pedestal height by using Uni-Shims™ whole or in segments at the top of pedestal assembly.

Final project grade

Laser line

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 5

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Deck

4. Assemble by rotating & aligning alphabets of one Stak-Cap™ with the Stak-Cap™ bellow it for slope compensa-tion.

5. Complete assembly by snapping on Spacer Tabs in order to provide proper spacing of pavers. Spacer tabs are perforated and can be ripped or cut off.

Leveling Shims

Level

3. Using a laser determine final height of pedestals from ½” to 2-¼” high. Consider in calculation the Buffer Pads as 1/8” thick.

STACK

ROTATE

Paving America one step at a time!Tile Tech Inc.®

2. Position Buffer Pads on chalk grid lines using the v-notch as a reference point.

Notch

Laser line

6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Orient the pedestal assembly so that the top Stak-Cap™ pair high side points towards decline of slope.

NotchChalk line

Spacer Tabs

Level

Page 6: Tile Tech Pedestal

UNI-JUST™ PEDESTAL SYSTEM

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

PRODUCT CHARACTERISTICS:ADJUSTABLE HEIGHT FROM 2-1/4” TO 24” WITH USE OF 4”ø SDR35 PVC PIPE.SELF-LEVELING CAP AUTOMATICALLY ADJUST SLOPE FROM 0% TO 4%.SCREW ADJUSTABLE WHILE PEDESTALS ARE LOADED FOR FINAL HEIGHT ADJUSTMENT OF 1-1/2”RESISTANT & IMPERVIOUS TO FREEZE-THAW, WATER, MOLD, ACID & ULTRAVIOLET DETERIORATION.RESISTANT TO TEMPERATURES BETWEEN -22°F AND +250°F.LARGE FOOT PRINT SPREADS WEIGHT OVER ROOFING MEMBRANE AND SUBSTRATEBUFFER PADS PROVIDE NOISE DAMPENING, SLIP RESISTANCE AND PROTECTION TO ROOFING MEMBRANE AND SUBSTRATE.MAXIMUM DESIGN CAPACITY OF 2,OOO LBS PER PEDESTAL.

4“ø SDR35 P

VC

SPACER TABS - 1/8” TABS CAN BE BROKEN OFF ALLOW DIFFERENT PAVING CONFIGURATION

UNI-CAP™SELF-LEVELING & ADJUSTABLEIN ANY DIRECTIONFROM 0% TO 4% SLOPE

UNI-INSERT™ - 3/4” & 1-1/2”SCREW ADJUSTMENT FROM 3/4” TO 1-1/2”OF ADDITIONAL HEIGHT

UNI-COLLAR™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE

UNI-BASE™SNAPS ON TO END OF 4”ø SDR35 PVC PIPE OR CAN BE USED WITHUNI-INSERT

BUFFER PADUSED UNDER BASE TO PROVIDESLIP RESISTANCE, NOISE DAMPENING& MEMBRANE PROTECTION

4”ø SDR35 PVC PIPE USER SUPPLIED & CUTTO REQUIRED HEIGHT

COMPONENT ASSEMBLY INSTRUCTIONS.HEIGHT ADJUSTMENT FROM 2-1/4” TO 24” & SLOPE ADJUSTMENT FROM 0% TO 4%

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 6

Paving America one step at a time!Tile Tech Inc.®

Page 7: Tile Tech Pedestal

UNI-JUST™ PEDESTAL INSTRUCTIONSINSTALLATION INSTRUCTIONS 1/2” to 24” HIGH & 0%-4% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

3. Cut PVC pipe to required height with a 12” chop saw. Using sand paper remove any burrs from cut ends.

5. Complete assemble by rotating & aligning Uni-Cap™ with Uni-Insert™. Align & attach Buffer Pad to Uni-Base.

9. Use Allen Key to fine tune loaded pedestal for a perfect level & height.

1. Chalk grid lines starting from door threshold based on paver size plus 1/8” gap.

8. Use a spirit level to level Uni-Cap in any direction.

Level

Final project grade

Laser line

Deck

7. Adjust final pedestal height by using Allen Key from top to screw up or down Uni-Insert™.

Final project grade

Laser lineAllen Key

Deck

4. Assemble by inserting cut PVC pipe in to Uni-Base™ and Uni-Collar™ in to other end of PVC pipe. Screw Uni-Insert™ in to Uni-Collar™ minimum of 2 threads.

4“ø SDR35 P

VC

6. Position pedestal under laser line and align Buffer Pad notch with chalk line.

Laser line

Notch

Chalk line

2. Using a laser determine final height of pedestals. Deduct ¼” for base & cap assembly. Measure & mark PVC pipe to be cut.

4“ø SDR35 P

VC

4“ø SDR35 P

VC

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 7

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 8: Tile Tech Pedestal

BASE SLOPE PLATEBASE SLOPE ADJUSTMENT FROM 0” TO 1” (0-8%) PER FOOT SLOPE.

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 8

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

4“ø SDR35 P

VC

90˚STACK AND ROTATE ONE PLATE RELATIVE TO ANOTHER TO COMPENSATE FOR A RANGE OF SLOPES. POINT BOTH FINGER TABS DOWN HILL FOR MAXIMUM SLOPE COMPENSATION.

FOR BASE LEVELING, BASE SLOPE PLATES (BSP) CAN BE STACKED UNDER UNI-BASE AND EACH PLATE COMPENSATES FOR 1/4” PER FOOT (2%) SLOPE AND ADDS 3/8” TO THE OVERALL HEIGHT OF PEDESTAL. A MAXIMUM OF FOUR PLATES MAY BE STACKED BELOW A PEDESTAL IN ORDER TO COMPENSATE FOR UP TO 1” PER FOOT (0-8%) SLOPE. ALWAYS USE A BUFFER PAD UNDER COMPLETE PEDESTAL ASSEMBLY.

BASE SLOPE PLATE APPLICATION - SECTION DETAILS

UNI-JUST™ PEDESTALS2” TO 22” HIGH

TILE TECH PAVERS

4“ø SDR35 P

VC

FINGER TABS

BUFFER PAD

4“ø SDR35 PVC

4“ø SDR35 PVC

0% SLOPE 2% SLOPE1 x BASE PLATE 4% SLOPE

2 x BASE PLATE 6% SLOPE3 x BASE PLATE

8% SLOPE4 x BASE PLATE

Paving America one step at a time!Tile Tech Inc.®

Page 9: Tile Tech Pedestal

UNI-SHIM™ APPLICATION1/8” & 1/16” RIGID SHIMS USED ON TOP AND UNDER PEDESTAL

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

A UNI-SHIM 1/8” OR 1/16” MAY BE PLACED ON TOP OF EACH PEDESTAL. UNIQUE INTERLOCKING FEATURE ALLOWS SHIMS LOCK TO EACH OTHER AND TO PEDESTAL TOPS, NO GLUING REQUIRED. SHIMS MAY BE USED WHOLE OR BROKEN INTO SEGMENTS FOR FINE TUNING & LEVELING.

UNI-SHIM™ 1/8” & 1/16”

UNI-SHIMS MAY BE PLACED ON TOP OF PEDESTALS FOR MINOR LEVELING OF PAVERS WITH THICKNESS VARIATIONS. USE NO MORE THAN 3 SHIMS STACKED PER CORNER.

UNI-SHIM™ TOP OF PEDESTAL

UNI-SHIM™ UNDER PEDESTAL

MAY BE CUT INTO SEGMENTS

ADHERE W/ POLYURE-THANE CONSTRUCTION

ADHESIVE DO NOT ADHERE TO SUBSTRATE

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 P

VC

PLACE UNI-SHIMS, WHOLE OR IN SEGMENTS, UNDER EACH PEDESTAL IN A STAIR STEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE NO MORE THAN 2 SHIMS, AND ADHERE THEM TO EACH OTHER WITH CONSTRUCTION ADHESIVE.

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 9

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 10: Tile Tech Pedestal

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 10

STAK-CAP™ & UNI-JUST™ PEDESTALS

COMPENSATION FROM 1/2” TO 36” HIGH & 0% TO 4% SLOPE

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

SPACERFIXED HEIGHT 1/8”

STAK-CAP™HEIGHT 3/8” SLOPE 1% Max

STAK-CAP™ X2HEIGHT 1” SLOPE 2% Max

STAK-CAP™ X3HEIGHT 1-3/8” SLOPE 3% Max

STAK-CAP™ X4HEIGHT 1-7/8” SLOPE 4% Max

STAK-CAP™ X5HEIGHT 2-¼” SLOPE 5% Max

UNI-JUST™ w/ PVC PIPE HEIGHT 3” TO 3-¾”SLOPE 0% TO 4%

UNI-JUST™ w/ PVC PIPE HEIGHT “VARIABLE” MAX 36”SLOPE 0% TO 4%

4“ø SDR35 P

VC

4“ø SDR35 P

VC

SAMPLE PEDESTAL CONFIGURATION & COMBINATION

UNI-JUST™ w/o PVC PIPEHEIGHT 2-¼” TO 3” SLOPE 0% TO 4%

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 11: Tile Tech Pedestal

SAMPLE DECK LAYOUTOVERVIEW OF PEDESTAL PLACEMENT

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

DOOR THRESHOLD PEDESTAL PLACEMENT

RADIUS PERIMETER PEDESTAL PLACEMENT

CORNER PERIMETER PEDESTAL PLACEMENT

DIAGONAL PERIMETER PEDESTAL PLACEMENT

LOW THRESHOLD PEDESTAL PLACEMENT

ROOF DRAIN PEDESTAL PLACEMENT

LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN

LPHPSLOPE 1/4” PERFOOTRD LP RD

HP

SEE ENLARGED SECTION PLANS:

A1

B1

C1

D1

E1

F1

A1

B1

C1

D1

E1

F1

1

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 11

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 12: Tile Tech Pedestal

SAMPLE INITIAL INSTALLATIONUSING “T” SHAPED PATTERN

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN

REMOVE SPACER TABSFROM PERIMETER

PEDESTALS AS NECESSARY

START PAVER AND PEDESTALINSTALLATION IN “T” SHAPED

PATTERN

START PAVER AND PEDESTALINSTALLATION FROM HIGH

POINT OR THRESHOLDUSING WHOLE PAVER

MAXIMUM 1/8” GAPAT PERIMETER

LP

HP

DETERMINE CAVITY HEIGHT AT ALL THRESHOLDS, DRAINS AND HIGH POINTS. DEDUCT THE THICKNESS OF THE PAVERS FROM THE MEASURED DISTANCE BETWEEN THE TOP OF THE MEMBRANE AND THE TOP OF THE PAVERS TO DETERMINE THE PEDESTAL HEIGHT NEEDED FOR EACH LOCATION. USE A LASER LEVEL TO MARK THE TOP OF PEDESTAL ELEVATION AROUND THE DECK. PLAN PAVER & PEDESTAL LAYOUT PATTERN BEFORE STARTING, BY MARKING GUIDELINES ON THE ROOF IF NEEDED. USING THE GUIDELINES INSTALL A “T” SHAPED PORTION OF THE NEW DECK STARTING FROM THE THRESHOLD OR HIGH POINT. PAVERS ON BOTH ROWS OF THE “T” SHOULD BE ADJUSTED TO THE CORRECT HEIGHT AND LEVELED BEFORE PROCEEDING. INSTALLATION ON ALL SIDES OF THE “T” CAN THEN PROCEED AT THE SAME TIME.

2

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 12

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 13: Tile Tech Pedestal

BOTTOM OF THRESHOLD

THRESHOLD PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1A

ENLARGED PLAN VIEW

THRESHOLD PEDESTAL APPLICATION - SECTION DETAILS

SLOPE DIRECTION

PERIMETER GAP1/8” MAX

VALLEY LINE

UNI-JUST™ PEDESTAL

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

SDR35 PVC

PERIMETER GAP 1/8” MAX

UNI-JUST™ PEDESTALS2” TO 24” HIGH & 0%-4% SLOPE

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

THRESHOLD & PEDESTALHEIGHT WILL VARIE

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

SLOPE

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 13

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 14: Tile Tech Pedestal

RADIUS PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1B

ENLARGED PLAN VIEW

RADIUS PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALADJUSTABLE 1/2” TO 24” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTAL

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTAL

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

SLOPE

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 14

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 15: Tile Tech Pedestal

CORNER PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1C

ENLARGED PLAN VIEW

CORNER PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 24” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTALS

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 15

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 16: Tile Tech Pedestal

DIAGONAL PERIMETER APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY.4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1D

ENLARGED PLAN VIEW

DIAGONAL PEDESTAL APPLICATION - SECTION DETAILS

ADHERE EDGE CUT PAVERTO TOP OF PEDESTAL

WITH SILICONE ADHESIVE

UNI-JUST™ PEDESTALSADJUSTABLE 1/2” TO 24” HIGH

TILE TECH PAVERS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFINGSLOPE TO DRAIN

ROOF DECK

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

INSULATION60psi MIN

SELF-LEVELING CAP0% TO 4% SLOPE

TILE TECH PAVERS

UNI-JUST™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABS ONPERIMETER PEDESTALS

TO SUPPORT PAVER EDGES

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

ADHERE EDGE CUT PAVERSTO PEDESTAL TOP

WITH SILICONE ADHESIVE

PERIMETER GAP1/8” MAX

SLOPE

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 16

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 17: Tile Tech Pedestal

LOW HEIGHT PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

1E

ENLARGED PLAN VIEW

LOW HEIGHT PEDESTAL APPLICATION - SECTION DETAILS

TILE TECH PAVERS

STAK-CAP™ PEDESTAL

PERIMETER GAP1/8” MAX

REMOVE EXTRA TABSON PERIMETER PEDESTALSTO SUPPORT PAVER EDGES

STAK-CAP™ (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE

TILE TECH PAVERS

INSULATION60psi MIN

RE-INSERT REMOVED TABS& ADHERE WITH SILICONE

REMOVE EXTRA SPACER TABON PERIMETER PEDESTALS

TOP OF PAVER DECKTOP OF PEDESTAL

TOP OF WATERPROOFING

PERIMETER GAP 1/8” MAX

SLOPE TO DRAINROOF DECK

B1

B1

STACK & ROTATE PEDESTALCAPS TO ADD HEIGHT AND CHANGE SLOPE

STACKABLE CAPS (5 MAX)1/2” TO 2-1/4” HIGH0% TO 5% SLOPE

SLOPE

USE UNI-SHIM™ ON TOPOR UNDER PEDESTAL FOR

FINE HEIGHT & SLOPE ADJ.

HP

USE UNI-SHIM™ FORFINE TUNING OF INDIVIDUAL PAVERS

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 17

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

SPACER TABS 1/8”

Paving America one step at a time!Tile Tech Inc.®

Page 18: Tile Tech Pedestal

DRAIN PEDESTAL APPLICATIONENLARGED PLAN VIEW & SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

1F

ENLARGED PLAN VIEW

DRAIN PEDESTAL APPLICATION - SECTION DETAILS

TILE TECH PAVERS

A1

USE UNI-SHIMS™ ON TOPOR UNDER PEDESTAL FOR

FINE HEIGHT & SLOPE ADJ.

4“ø SDR35 P

VC

4“ø SDR35 P

VC

4“ø SDR35 PVC

4“ø SDR35 PVC

4“ø SDR35 PVC 4“ø SDR35 PVC

SLOPE TO DRAIN SLOPE TO DRAIN

STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH0% TO 5% SLOPE5 UNITS MAX

UNI-JUST™ PEDESTALSADJUSTABLE HEIGHT2-1/4” TO 24”0% TO 4% SLOPE

OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL

ROOF DRAINS

OVER DRAIN PAVERSOR STEEL PLATE (1/4” MIN)USE ADDITIONAL PEDESTAL UNI-JUST™ PEDESTALS

2-1/4” TO 24” HIGH

TILE TECH PAVERS

CLAULKING

METAL COUNTERFLASHING

WATERPROOF MEMBRANE

STAK-CAPS™ PEDESTALS1/2” TO 2-1/4” HIGH

ROOF DECK

ROOF DRAIN60psi MIN INSULATION

A1

ROOF WALL JUNCTURE

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 18

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 19: Tile Tech Pedestal

PERIMETER EDGE RESTRAINT OPTIONSMETAL FLASHING AND WOOD FASCIA CONTAINMENT DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LEDGER BOARD

FASCIA BOARD FLUSH WITHTOP OF PAVER

ROOF DECK

4“ø SDR35 P

VC

METAL FLASHING CONTAINMENT

WOOD FASCIA CONTAINMENT

ROOF DECK

4“ø SDR35 P

VC

TILE TECH PAVERS

DECK SCREWS

FASCIA BOARD MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF FASCIA BOARD CAN BE CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.

METAL FLASHING MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA-PET. BOTTOM OF METAL FLASHING CAN BE BENT OR CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN.

LEDGER BOARD

TWO PIECE EDGE METAL

TILE TECH PAVERS

DECK SCREWS

PRE-FINISH METAL22GA. GALV.

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 19

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 20: Tile Tech Pedestal

PERIMETER EDGE RESTRAINT OPTIONSSTEP-DOWN AND GREEN ROOF CONTAINMENT DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.

ROOF DECK

4“ø SDR35 P

VC

STEP-DOWN CONTAINMENT

GREEN ROOF CONTAINMENT

FASCIA BOARD FLUSHWITH TOP OF PAVER

ROOF DECK

4“ø SDR35 P

VC

TILE TECH PAVERSVARIABLE RISER HEIGHT

(PER CODE)

LEDGER BOARD

UNI-JUST™ PEDESTALS2-1/4” TO 24” HIGH

ENGINEERED GREENROOF SOIL

FILTER FABRIC

L-CHANNEL WITHDRAIN HOLES

TILE TECH PAVERS

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 20

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 21: Tile Tech Pedestal

STEP-DOWN PEDESTAL APPLICATIONSTEP-DOWN PEDESTAL APPLICATION SECTION DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

2

TILE TECH PAVERS

ROOF DECK

UNI-JUST™ PEDESTALS2-1/4” TO 24” HIGH

LEDGER BOARD

FASCIA BOARD FLUSH WITHTOP OF PAVERS

VARIABLE RISER HEIGHT(PER CODE)

LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS.

4“ø SDR35 P

VC

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 21

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 22: Tile Tech Pedestal

WOOD TILE & PEDESTAL APPLICATIONTRANSITION, ALIGNMENT & LOCK DOWN DETAILS

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

IPE WOOD & PAVER TRANSITION AND ALLIGNMENT

TILE TECH PAVERS™

UNI-SHIM™ USED FOR INDIVIDUAL

WOOD / PAVER ALIGNMENT

TILE TECH IPE™ WOOD

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 22

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

INSERT THE LOCK WASHER IN TO THE KURF CUT BETWEEN THE UPPER SLAT AND BOTTOM RAIL OF 3 WOOD PAVERS. INSERT THE 4th PAVER IN TO THE 4TH CORNER. ONCE ALL 4 PAVERS ARE TIGHTLY IN PLACE INSERT DECK SCREW (1-1/4” LONG) THROUGH LOCK WASHER AND HAND TIGHTEN IN TO PEDESTAL TOP UNTIL ALL 4 PAVERS ARE SECURELY FASTENED TO THE PEDES-TAL. DO NOT OVER TIGHTEN.

4“ø SDR35 P

VC

Paving America one step at a time!Tile Tech Inc.®

UNI-JUST™ PEDESTAL

DECK SCREW1-1/4” LONG

LOCK WASHER

Page 23: Tile Tech Pedestal

IPE WOOD TILES DETAILS20” x 20” x 1-1/2”

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 23

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

CROSS MEMBERTOP VIEW

Paving America one step at a time!Tile Tech Inc.®

Page 24: Tile Tech Pedestal

IPE WOOD TILES DETAILS24” x 24” x 1-5/8”

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.COM

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 24

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

CROSS MEMBERTOP VIEW

Paving America one step at a time!Tile Tech Inc.®

Page 25: Tile Tech Pedestal

JOIST DECK & PEDESTAL APPLICATIONJOIST DECK INSTALLATION DETAILS & SPANNING CHART

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

NOTE:THIS DIAGRAM AND CHART ARE FOR CONVENIENCE ONLY. COMPATIBILITY OF DECKING MATERIAL AND JOIST SPANNING WILL VARY DEPENDING ON THE TYPE / SIZE OF CONCRETE PAVERS, WOOD OR COMPOSITE MATERIALS BEING USED. ADDITIONALLY CODE REQUIREMENTS VARY PER LOCATION AND IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE DECK MEETS CODE REQUIREMENTS.

2x8

2x10

12" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 10' - 0" 4x6 OR (2) 2x6 24" O.C.

13' - 2" 4x8 OR (2) 2x8 24" O.C.

16' - 10" 4X10 OR (2) 2x10 24" O.C.

16" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 9' - 1" 4x6 OR (2) 2x6 24" O.C.

2x8 12' - 0" 4x8 OR (2) 2x8 24" O.C.

2x10 15' - 2" 4X10 OR (2) 2x10 24" O.C.

20" O.C. JOIST SPACING

JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING

2x6 7' - 11" 4x6 OR (2) 2x6 24" O.C.

2x8 10' - 2" 4x8 OR (2) 2x8 24" O.C.

2x10 12' - 5" 4X10 OR (2) 2x10 24" O.C.

JOIST SPAN

TILE TECH PAVERS

UNI-SHIM™

JOIST PLATE

PEDESTAL SPACING

UNI-JUST™ PEDESTALWITH JOIST CAP

JOIST HANGER

JOIST SPACING

BEAM SIZE1-4x OR 2-2x

DECK PLANKS

JOIST

JOIST HANGER

4“ø SDR35 PVC

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 25

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Paving America one step at a time!Tile Tech Inc.®

Page 26: Tile Tech Pedestal

WIND-LOC™ PAVER & PEDESTAL APPLICATIONPAVER LOCK DOWN SYSTEM DETAILS. PLAN AND PROFILE VIEW

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

WIND-LOC™ - PROFILE VIEW

WIND-LOC™ PEDESTAL IS MADE OF HIGH IMPACT POLYPRO-PYLENE & ABS AND IS MADE TO LOCK THE PAVER SYSTEM TOGETHER AND PREVENT WIND UPLIFT. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON GRID LINES. SET THE WIND-LOC™ BASE ON TOP OF THE PEDESTAL SYSTEM AND SET WIND-LOC™ PAVERS ON TO WIND-LOC™ BASE. BE SURE TO ALIGN RECESS ON BACK SIDE OF PAVER WITH THE DOMES ON THE WIND-LOC™ BASE. POSITION & ALIGN WIND-LOC™ PLATE ON TO WIND-LOC™ PAVERS IN A DIAMOND CONFIGU-RATION. INSTALL WIND-LOC™ SCREW IN TO WIND-LOC™ BASE WITH A HEX BIT. TIGHTEN DOWN TO 80 PSI. DO NOT OVER TIGHTEN.

WIND-LOC™ PLATE

WIND-LOC™ SCREW

WIND-LOC™ BASE

WIND-LOC™ PAVERS

WIND-LOC™ PAVERSWIND-LOC™ SCREW

WIND-LOC™ PLATE

WIND-LOC™ BASE

UNI-JUST™ PEDESTAL

4“ø SDR35 PVC

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 26

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

Patent Pending

Pat. # 8,453,391 & Pat. Pen

Paving America one step at a time!Tile Tech Inc.®

Page 27: Tile Tech Pedestal

HEX-TRAY™ SNOW MELT SYSTEMPAVER SNOW MELT SYSTEM DETAILS. PLAN AND PROFILE VIEW

GENERAL NOTES: APPLY TO ALL OF THE ABOVE PRODUCTS1. INSTALLATION MUST BE COMPLETED IN ACCORDANCE WITH TILE TECH INC PRODUCT SPECIFICATIONS.2. DRAWING NOT TO SCALE.3. USE OF BUFFER PADS IS MANDATORY. 4. CONTRACTOR’S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.TILETECHPAVERS.com

HEX-TRAY™ SNOW MELT - PROFILE VIEW

HEAT TRANSFER PLATE

TILE TECH PORCELAIN

FOAM INSULATION

Hex-Tray™ Snow Melt System

4“ø SDR35 PVC

COPYRIGHT 2015 TILE TECH INC. , ALL RIGHTS RESERVED. Page 27

National Distribution Tel: 213-380-5560Fax: 213-380-5561Toll Free: 888-380-5575

HEX-TRAY™

PEX TUBING CHANNELS

4“ø SDR35 PVC

PEX TUBINGCHANNELS

TILE TECH PORCELAIN PAVERS

FOAM INSULATION

HEX-TRAY™

HYBRID PEDESTAL SYSTEM

HEAT TRANSFER PLATE

Patent Pending

Pat. # 8,850,753 & Pat. Pen

PEX TUBING

HEX-TRAY™ SNOW MELT SYSTEM COMPONENTS INCLUDES A HONEYCOMB STRUCTURAL TRAY WITH PEX TUBING CHANNELS, A FOAM INSULATION PANEL, ALUMINUM HEAT TRANSFER PLATE AND USER SUPPLIED ½“ PEX TUBING. PRE ASSEMBLE THE FOAM INSULATION PANEL TO THE BACK OR BOTTOM SIDE OF THE HEX-TRAY AND SECURE WITH SUPPLIED CORK-SCREW. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON TO GRID LINES. PLACE SEMI ASSEMBLED HEX-TRAY™ ON TO PEDESTAL SYSTEM. LEVEL & SECURE FOUR ADJACENT CORNERS TO PEDESTAL SYSTEM USING HEX-LOCK DISK AND SECURE WITH DECK SCREW (1-1/4” LONG). POSITION AND ALIGN HEAT TRANSFER PLATE TO TOP OF HEX-TRAY™. AT TERMINATION POINTS AND WALLS, CUT BACK HEAT TRANSFER PLATE TO EXPOSE THE “U” SHAPED CHANNELS IN ORDER TO LOOP BACK PEX TUBING. INSTALL PEX TUBING AND TEST FOR LEAKS. INSTALL PORCELAIN PAVERS.

Paving America one step at a time!Tile Tech Inc.®

Page 28: Tile Tech Pedestal

Visit our website at www.tiletechpavers.com

for complete design details and photo gallery

Paving America one step at a time!Tile Tech Pedestal®

© 2021 Tile Tech Inc

HP-D 01/15