tlg-series€¦ · 2 circuit 4 see circuit designation chart. 12 lamp voltage / 125n 5 basic switch...

5
Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com TLG-Series TLG-Series ROCKER SWITCHES The TLG-Series Mid-Sized Tippette snap-in rocker switches are single pole, rocker or paddle actuated with an adjacent indicator light. These single-actuator-switches are AC rated to 20 amps and are also suitable for low voltage DC applications. Product Highlights: • Maintained or Momentary Circuitry • Rocker Paddle or mixed Rocker/Paddle actuators • Illuminated or Non-Illuminated • Integrated wire lead construction Typical Applications: Appliance HVAC Food Service Transportation

Upload: others

Post on 18-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TLG-Series€¦ · 2 CIRCUIT 4 See Circuit Designation Chart. 12 Lamp Voltage / 125N 5 BASIC SWITCH NUMBER TA On-None-Off TB On-None-On TC On-Off-On LTA On-None-Off, Lighted 6 RATING

Carling Technologies, Inc.60 Johnson Avenue, Plainville, CT 06062Email: [email protected] Support: [email protected]: 860.793.9281 Fax: 860.793.9231

www.carlingtech.com

TLG-SeriesTLG-Series ROCKER SWITCHESThe TLG-Series Mid-Sized Tippette snap-in rocker switches are single pole, rocker or paddle actuated with an adjacent indicator light. These single-actuator-switches are AC rated to 20 amps and are also suitable for low voltage DC applications.

Product Highlights:• MaintainedorMomentaryCircuitry• RockerPaddleormixedRocker/Paddleactuators• IlluminatedorNon-Illuminated• Integratedwireleadconstruction

Typical Applications:• Appliance• HVAC• FoodService• Transportation

Page 2: TLG-Series€¦ · 2 CIRCUIT 4 See Circuit Designation Chart. 12 Lamp Voltage / 125N 5 BASIC SWITCH NUMBER TA On-None-Off TB On-None-On TC On-Off-On LTA On-None-Off, Lighted 6 RATING

Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com

2 | TLG-Series Rocker Switches - General Specifications, Ordering Scheme, Dimensional Specifications

*Manufacturer reserves the right to change product specification without prior notice.

INTEGRATED WIRE LEAD(no exposed conductors)

TERMINAL TYPE

PADDLE SHORT PADDLE MOUNTING HOLEPanel Thickness:.020[.508] min. to .250[6.35] max.

.187 TAB (Q.C.).250 TAB (Q.C.) SOLDER LUG

.156[1.75] DIA.069[1.75] DIA .055[1.75] DIA

.500[12.70]

.390[9.90]

.275[6.98]

.520[13.20].220[5.59]

.250[6.35]

.187[4.74]1.240[31.49]

1.120[28.44].994[25.24]

1.000[25.40]

1.125[28.57]

6.000[152.40]

.250[6.35]

.050[1.27]

.375[9.52]

.375[9.52]

.812[20.62]

1.155[29.33] .250[6.35]

Dielectric Strength Electrical Life Operating TemperatureUL/CSA: 1000V - live to dead metal parts

50,000 cycles - maintained25,000 cycles - momentary

32°F to 185°F (0°C to 85°C)

1Base Part Number

2Circuit

3Lens Design

4Lens Color

5Center Position

7Termination

6Rating

8Actuator Style

10Base Color

11Lens Color

9Actuator Color

TLG G D TA 1R 20 T BB

8 ACTUATOR STYLE 2P Paddle

PS Short PaddleT Rocker

9 ACTUATOR COLORunlighted 2B BlackW White

lighted A AmberC ClearG GreenLU BlueR Red

10 BASE COLOR 2B Black W White

11 LENS COLOR 1,3A AmberC Clear

G GreenLU Blue

R RedW White

4 LENS COLORA AmberC Clear

G GreenR Red

W White

12 LAMP VOLTAGE 1incandescent6V 6 volt12V 12 volt 18V 18 volt 24V 24 volt 28V 28 volt

neon125N 125 volt neon250N 250 volt neon

1 BASE PART NUMBER: SERIESTLG Single Pole with adjacent Indicator Light

3 LENS DESIGND DiamondL Long Line

2 CIRCUIT 4See Circuit Designation Chart.

12Lamp Voltage

125N/

5 BASIC SWITCH NUMBERTA On-None-OffTB On-None-On

TC On-Off-OnLTA On-None-Off, Lighted

6 RATING10 5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC11 5A 250VAC, 10A 125VAC, 5A 125VAC L20 10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC21 10A 250VAC, 15A 125VAC22 10A 250VAC, 15A 125VAC, 20A 125-250VAC H, 3/4HP 125-250VAC

7 TERMINATION / FUNCTION Solder Lug .250 Tab QC .187 Tab QC Wire LeadsOn-None-Off 0 1 3 5 (On)-None-Off A B D F On-None-(Off) L M R T On-None-On 0 1 3 5 On-None-(On) A B D F On-Off-On 0 1 3 5

Notes: Imprinting is available. Consult factory.Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.1 Neon Lamps not recommended with green or blue actuators and lenses.2 Custom colors are available. Consult factory.3 Specify lens color only if actuator is lighted paddle.4 Available with circuits G, H, I, J, K only. ( ) Indicates momentary function.

Page 3: TLG-Series€¦ · 2 CIRCUIT 4 See Circuit Designation Chart. 12 Lamp Voltage / 125N 5 BASIC SWITCH NUMBER TA On-None-Off TB On-None-On TC On-Off-On LTA On-None-Off, Lighted 6 RATING

Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com

3 | TG/LTG, TTG, TLG-Series - Circuit Designation Chart

6

5

4

J

5

6

E

5

T

4

5

2

3

B C

3

2

D

5

6

1

2

3 6

5

4

6

Z

I

36

5

4

6

5

4

1

2

6 3 36 6

1

2

3

3

G

2

H

3

5

4 1

2

2

1

2

3

2

A

1

2

3

3 6 3

2

3

1

2

25

F

3

4

5

1

2

1

2

36

5

4 4

6

2

2

1

3

Q

1 1 4

5 2 25 5

R

1

3

4

5

6

S

6 6

CONTACT TERMINAL AND SWITCH LEVER

BULB

3

V W

6 3 3

Y

1 4 1

2 5 2

3

2

1

6

P

3

2

14

5

3 3

U

6

4 14 14 4 4

ISOLATED TERMINALDoes not make contact with switching lever

CONTACT TERMINALWill make contact with switching lever

LK M N O

Circuit Designation Chart:

Page 4: TLG-Series€¦ · 2 CIRCUIT 4 See Circuit Designation Chart. 12 Lamp Voltage / 125N 5 BASIC SWITCH NUMBER TA On-None-Off TB On-None-On TC On-Off-On LTA On-None-Off, Lighted 6 RATING

Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com

4 | Sales Representatives, Distributors & Company Profile

Authorized Sales Representatives and Distributors

About Carling

Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO9001 and IATF16949 registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile.

To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications

Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep.

EUROPE

MIDDLEEAST

SOUTHAMERICA

ASIA-PACIFICOCEANIA

AFRICAMEXICO

USA

CANADA

Page 5: TLG-Series€¦ · 2 CIRCUIT 4 See Circuit Designation Chart. 12 Lamp Voltage / 125N 5 BASIC SWITCH NUMBER TA On-None-Off TB On-None-On TC On-Off-On LTA On-None-Off, Lighted 6 RATING

Worldwide HeadquartersCarling Technologies, Inc.60 Johnson Avenue, Plainville, CT 06062Phone: 860.793.9281 Fax: 860.793.9231Email: [email protected]

Northern Region Sales Office: [email protected] Region Sales Office: [email protected] Region Sales Office: [email protected] Region Sales Office: [email protected] America Sales Office: [email protected]

Asia-Pacific HeadquartersCarling Technologies, Asia-Pacific Ltd.,Suite 1607, 16/F Tower 2, The Gateway,Harbour City, 25 Canton Road,Tsimshatsui, Kowloon, Hong KongPhone: Int + 852-2737-2277 Fax: Int + 852-2736-9332Email: [email protected]

Shenzhen, China: [email protected], China: [email protected], India: [email protected], Taiwan: [email protected], Japan: [email protected]

Europe | Middle East | Africa HeadquartersCarling Technologies LTD4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UKPhone: Int + 44 1392.364422 Fax: Int + 44 1392.364477Email: [email protected]

Germany: [email protected]: [email protected]

www.carlingtech.com REV_11_2019