Page 1: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water
Page 2: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Application Drawings

Bosch Bosch Combi Boiler with Three Zones………………………………………………... 1 Bosch Tankless Water Heater with Tank Loading …………………………………..... 2 Bosch Tankless Water Heater with Recirculation……………………………...……… 3 Bosch Tankless Water Heater with Recirc- Restricted………………………...……… 4 Lochinvar 2 WHNs with DHW with Buffer Tank & DHW on System Side………….…….......... 5 Wiring for 2 WHNs Cascading with Lochinvar Smart Control ………………………. 6 2 KBNs with DHW on System Side of Hydro Separator…………………………….... 7 Wiring for 2 KBNs with Tekmar 275 Control………………………………………… 8 Taco iRadiant 3-Way Mixing Piping & Wiring…………………………………………… 9 Tekmar Basic Radiant with Tekmar 360….…………………………………………………... 10 tN2 with Tekmar 402 House Control………………………………………………... 11 tN2/tN4 Hybrid System Tekmar 423, 334, 313….…………………………………… 12 664 Snowmelt with Tekmar 040…………………………….……………………...... 13 Viessmann Vitronic 200 with Taco SR & ZVC Controls………………………………………… 14 WB1Bc Combi with Two Zones Heat………..………………………………............ 15 Vitodens WB1B DHW Priority using Relay Boxes…….…………………….……… 16 WB1B and WB2B Venting with Centrotherm……………………………………….. 17-18 Wilo Stratos Pump with Relay………………………………………………………......... 19 Stratos Pump Using Ext Off Module..………….…………………………………… 20 Dual Pump Wiring…………………………………………………………….…….. 21 Stratos 0-10V with Honeywell 775M Control………………………………………. 22 Top S Wiring “Optional Internal Protection”………………………………………… 23

Page 3: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Reference Drawings

Raywal Hydro-Separator Support……………………………………………………. 24 Lochinvar WHN Hi Vent…………………………………………………………….. 25 Basic Snowmelt/Axiom………………………………………………………........... 26 Basic Snowmelt Wiring with TK150 & SM97…….…………………………........... 27 Wiring Diagram for 2-stage Heat using RIB Relay……………………..……........... 28-29 Isolation Relay for High Amperage Pumps…………………………………………... 30 Multiple Chiller Piping & Wiring Using T775 Chiller Staging Control with Buffer..... 31 Solar Retrofit with DHW …………………………….……………………….......... 32

Product Specifications AIC Heat Exchanger Specifications & Sizing……………………………................ 33-36 Aquatherm PP-R Pipe and Fittings…………………………………………………. 37-38 Bosch Tankless Heater Flow vs Delta T……………………………………………. 39 Caleffi Balance Valve Series 132…………………………………………………… 40 Caleffi Hydro Separator Series 548.………...……………………………................ 41 Caleffi DirtCal Series 5462.………...…………….………………………................ 42 Centrotherm Flexible Chimney Liner……………………………………................. 43 Grundfos Up 10-16/ Recirc Pump………...………………………………………… 44 Grundfos UPS 15-55/ Alpha Pump Chart………………………………..…………. 45 Grundfos UPS 32-60/ Magna Pump Chart………………………………………….. 46 Grundfos UPS 32-100/ Magna Pump Chart………………..……………………….. 47 Grundfos UPS 15-58FC Pump Chart…………………………………….................. 48 Grundfos UPS 26-99FC/Superbrute Pump Chart………………………................... 49 Grundfos Super Brute Pump Curves……………………..…………………………. 50 Lochinvar Squire Buffer Tank SBT………………………………………………… 51-52 Lochinvar Squire StorageTank SIT………………………………………………… 53-55 Lochinvar WHN Specification……….…………………………………................... 56 SunReports Apollo 1 Energy Monitor ……………………………………………… 57-58 SunReports Apollo 2 Energy Monitor ……………………………………………… 59-60 Taco Pump Curves……………………………………………………...................... 61 Taco I Series Radiant Mixing Valve……………………………………................... 62-63 Tekmar 3-Way Mixing Valves Sizing……………………………………................ 64-65 Tekmar 710A Mixing Valve Repair........................................................................... 66 Tekmar 710B Mixing Valve Repair............................................................................ 67 Turbomax Product Specifications............................................................................... 68 Viega Tech Data……….............................................................................................. 69 Viega Pressure Drop………………............................................................................ 70-71 Viega Snowmelt Tube Spacing & Water Temperature …………….………............. 72 Viega Typical Tube Spacing………………………………………………………… 73 Viega Stainless Manifold w/ Balancing Valves.......................................................... 74 Viessmann CM2 Technical Data……………………………………………………. 75-76 Viessmann WB2B Pressure Drop Chart……………………………………………. 77

Page 4: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Webstone EXP DHW service Valves……………………………………………….. 78 Webstone Hydro-Core piping kits………………………………………………….. 79-80 Wilo Eco Pump Specifications……………………………………………………... 81 Wilo Stratos Pump Specifications…………………………………………………… 82 Wilo Stratos D Pump Specifications………………………………………………… 83-84 Wilo Top S Pump Specifications…………………………………………………… 85

Quick Sheets Buderus AM10 Quick Sheet...................................................................................... 86-87 Bosch Combi FW200 Control Quick Start Guide………………………………… 88-89 HBX HydroBloc Quick Set-Up…………………………………………………… 90 Lockinvar Knight Quick Set-Up................................................................................ 91-92 Tekmar 275 Modulating Boiler Control …............................................................. 93 Tekmar 400 House Control Mod Ranges…………………………………………... 94 Viessmann WB1Bc Combi Programming…………………………………………. 95 Viessmann WB2B Quick Start-up Sheet................................................................... 96-99 Wilo Stratos Quick Start Guide……………………………………………………. 100 Wilo Stratos Troubleshooting Guide………………………………………………. 101 Expansion Tank Sizing............................................................................................... 102-104 Pipe Volumes…………….………………………………………………………… 105 Conversion Factors..................................................................................................... 106

Page 5: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-

721-

0303

FAX

781

-721

-911

9

WW

W.C

AP

CO

SUP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CEP

T D

RA

WIN

G. A

LL C

ON

DIT

ION

S AN

D N

EC

ESSA

RY

CO

MP

ON

ENTS

MU

ST B

E FI

ELD

VER

IFIE

D

AND

AR

E T

HE

RE

SPO

NSI

BILI

TY O

F TH

E IN

STAL

LIN

G C

ON

TRAC

TOR

10 IN

DU

STR

IAL

PA

RK

WA

YW

OB

UR

N M

A 0

1801

EN

ER

GY

SU

PP

LY, I

NC

.

Gre

enst

ar c

ombi

1.29

.13

GP

4 pi

pe d

iam

eter

Clo

se s

pace

tee’

s

HP

BO

SC

HG

reen

star

Com

bi

FACTORYINSTALLED

TRANSFORMER

24 V

AC

PO

WE

RS

R 5

03ZO

NE

1

ZON

E

2ZO

NE

3

ZON

E

1ZO

NE

2

ZON

E

3

FUS

E 1

A

MP

NP

ZCH

X 1

X2

ZRTHR

EE

ZON

E S

WIT

CH

ING

RE

LAY

WIT

H O

PTI

ON

AL P

RIO

RIT

YP

OW

ER

ZON

E 1

ZON

E 2

ZON

E 3

120V

LpN

pS

yste

mP

ump

outdoorT TbusB B 4 2 1 F A

LsN

sN

LrL

N

Boi

ler

Pum

p

SupLLHHi

LimitFlow

L

BO

SC

HG

reen

star

OS

FW 200 B

B

VF

VF

HP

120V

1"

1 ¼

1

Page 6: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Data subject to change without notice | 01.2011 BOSCH THERMOTECHNOLOGY CORPORATION

THERM Tankless Water Heater Applications Manual

12.2 Basic tank loading with domestic recirculation

The following application outlines general tank loading with one or more gas tankless water heaters in parallel. Domestic hot water recirculation shown is optional.

System parameters:

• Aquastat/tank sensor Tset 120-140°F, <10°F differential. • 30-119 gallon storage tank recommended• DHW return line can tie directly into tank if � ttings are available.• Individual pumps (i.e. UP26-99) can be used on supply to each heater or one pump (as shown) for the entire system

See Chapter 5.1 and 5.2 for pump parameters

Symbols

Service valve

Pressure reliefvalve

Solarstoragetank

Flowdirection

Well thermometer

Bronze or stainlesssteelcirculator

Potable water expansion tank

Flowcheckvalve

DomesticHot Water supply

ColdWaterSupply

Aquastator tank sensor

DHW recirculationpump

Hot water recirculation return line

Drain valve

Applicable Bosch Models: •Bosch 830 ES •Bosch 940 ES •Bosch C 1050 ES •Bosch C 1210 ES/ESC

Aquastat / Water Heater setpoints

Model Number Aquastat setpoint Water heater setpoint

C 1210 ESC �140°F 14°F above Aqua-stat setpoint

830 ES, 940 ES, C 1050 ES, C 1210 ES

�126°F* 140°F

* If local codes require higher setpoint or to increase the recovery capacity of the water heater, contact Bosch Thermotechnology.

Circulator Pump must be sized for total flow and Pressure Drop of appliance/s.

2

Page 7: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Data subject to change without notice | 01.2011 BOSCH THERMOTECHNOLOGY CORPORATION

THERM Tankless Water Heater Applications Manual18 |

8.2.3 Bosch gas water heater with domestic recirculation loop The circulator should be controlled by an external aquastat or with a timer to run only during times of expected hot water usage.Insulate piping in hot water recirculation loop to limit heat loss.

Ariston Pro mini-tank(2.5, 4 and 8 gallon sizes)

ColdHot

Note: Drawing is not to scale.Cold water piping to fixtures not shown for clarity purposes.

Symbols

Service valve

SinkStandard tub fixture

Bronze or stainless steelcirculator pump sized according to UPC standards(Taco Bronze 007 or Grundfos 15-42B will cover most homes up to 3 bathrooms)

Potable water expansion tank

Flow check valve Flow directionTimer

Aquastat

Applicable Bosch Models: •Bosch 520 PN •Bosch 520 HN•Bosch 830 ES •Bosch 660 EF •Bosch 660 EFO •Bosch 940 ES•Bosch 940 ESO •Bosch C 1050 ES•Bosch C 1210 ES

See Chapter 5 for recirculation pump parameters

Bosch Re-Circ Application

3

Page 8: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Data subject to change without notice | 01.2011 BOSCH THERMOTECHNOLOGY CORPORATION

THERM Tankless Water Heater Applications Manual | 19

8.2.4 Bosch gas water heater with direct recirculation loop Use a circulator, aquastat and/or timer, to keep a loop of hot water constantly hot and ready to use. This limits wait time for hot water delivery to the tap and excessive waste of water. Insulate piping in hot water recirculation loop to limit heat loss.

If the water heater is used within an approved hot water recirculation application and supplied with circulated water, the heat exchanger warranty is decreased. Please refer to the installation manual for detailed warranty period information.

Note: Drawing is not to scale.Cold water piping to fixtures not shown for clarity purposes.

Symbols

Pressure reliefvalve

Service valves

Flowdirection

Bronze or stainless steelcirculator/pump

Aquastat Timer Flowcheckvalve

Potablewaterexpansiontank

Coldwatersupply

Hot Cold

Domestichot water tap

Domestichot water tap

Domestichot water tap

Domestichot water tap

Y-strainer

Applicable Bosch Models: •Bosch 520 PN •Bosch 520 HN•Bosch 660 EF/EFO •Bosch 830 ES •Bosch 940 ES/ESO •Bosch C 1050 ES•Bosch C 1210 ES/ESC

See Chapter 5.1 for recirculation pump parameters

Heat exchanger warranty is decreased in this

application unless a motion sensor type control

is used to power up the circulator.

4

Page 9: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

BP1

BP2

P1

SS

781-

721-

0303

FAX

781

-721

-911

9

WW

W.C

AP

CO

SUPP

LY.C

OM

THIS

IS O

NLY

A C

ON

CEP

T D

RAW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

ECE

SSAR

Y C

OM

PON

EN

TS M

US

T BE

FIE

LD V

ER

IFIE

D A

ND

A

RE

THE

RES

PON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRA

CTO

R

10 IN

DU

STR

IAL

PAR

KWAY

WO

BU

RN

MA

018

01

EN

ER

GY

SU

PP

LY, I

NC

.

2-W

HN

s w

ith B

uffe

r Tan

k 7.

19.1

1G

P

WH

N28

5P

3W

HN

285

AH

-1A

H-2

AH

-3A

H-4

Mix

1

Rad

iant

SIT

119

P2

STA

DLE

R

Vie

ga

STA

DLE

R

Vie

ga

Mix

S

enso

rD

HW SB

T050

5

Page 10: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

P1

BP

1

120

v

Boi

ler 1

BP

2

120

v

Boi

ler 2

ZON

E 4

PR

IOR

ITY

MAI

NE

S

F U S E 3 A

ZVC

404

FOU

R Z

ON

E Z

ON

E V

ALV

E C

ON

TRO

LW

ITH

OP

TIO

NA

L PR

IOR

ITY

ZON

E 4

RE

LAY

N/O

CO

M N

/C

ZON

E 1

1 2

3

4

ZON

E 2

1 2

3

4

ZON

E 3

1 2

3

4

ZON

E 4

1 2

3

4ON

OF F

T T

ZON

E 2

T T

ZON

E 3

T T

ZON

E

4

NO

RM

ALMO

DE R

ESE

TP

OW

ER

INT

TZO

NE

1

EXT

RA E S

FACTORYINSTALLED

TRANSFORMER

T ST

AT 1

VALV

E 1

T ST

AT 2

VALV

E 2

T S

TAT

3V

ALV

E 3

T S

TAT

4V

ALV

E 4

POW

ER

Hyd

ro A

ir Zo

nes

120 V

(ac)

Cla

ss 2

Tran

sfor

mer

24V

(a

c)

C

NL R

OSSS Dhw

Boi

ler 2

Boi

ler 1

4 w

ire

ZV3

wire

ZV

2 w

ire

PH4

wire

P

H

10A

10A

360

1213

1415

1617

18Do

not

appl

y pow

er

UnO

Com

Mix

Boil

Com

OutI

ndr

Sw

12

46

Mixin

gDe

mand

Powe

rL

NS

ys Pmp

N

35

78

910

11Po

were

d Outp

ut

Boile

rR

RC

Opn

Cls

13

2Co

m COp

nCl

s

BS MSOS

Boi

ler 1

ZON

E 4

P

RIO

RIT

Y

MAI

NE

S

F U S E 3 A

ZVC

404

FOU

R Z

ON

E Z

ON

E V

ALV

E C

ON

TRO

LW

ITH

OPT

ION

AL

PR

IOR

ITY

ZON

E 4

REL

AYN

/O C

OM

N/C

ZON

E 1

1 2

3

4ZO

NE

21

2

3 4

ZON

E 3

1 2

3

4ZO

NE

41

2

3 4

ON

OF F

T T

ZON

E 2

T T

ZON

E 3

T T

ZON

E 4

NO

RM

AL

MO

DE R

ESE T

POW

ER

IN

T T

ZON

E 1

EXTR

AE

SFACTORY

INSTALLEDTRANSFORM

ER

T S

TAT

1VA

LVE

1T

STA

T 2

VALV

E 2

T ST

AT 3

VAL

VE

3T

STAT

4V

ALV

E 4

POW

ER

2 w

ire

PH

4 w

ire

PH

123

P2

P3

4 w

ire

PH

2 w

ire

PH

Rad

iant

Zon

es

781-

721-

0303

FAX

781

-721

-911

9

WW

W.C

AP

CO

SUPP

LY.C

OM

THIS

IS O

NLY

A C

ON

CEP

T D

RA

WIN

G. A

LL C

ON

DIT

ION

S A

ND

NEC

ESS

ARY

CO

MPO

NE

NTS

MU

ST

BE

FIEL

D V

ER

IFIE

D A

ND

A

RE

TH

E R

ESP

ON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRA

CTO

R

10 IN

DU

STR

IAL

PAR

KWAY

WO

BU

RN

MA

018

01

EN

ER

GY

SU

PP

LY, I

NC

.

2-W

HN

s w

ith B

uffe

r Tan

k C

asca

ding

Con

trols

7.19

.11

GP

6

Page 11: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

C A L E F F I

P1

P2P3

S1

or

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PCO

SU

PP

LY.C

OM

THIS

IS O

NLY

A C

ON

CE

PT D

RAW

ING

. ALL

CO

ND

ITIO

NS

AND

NE

CE

SSA

RY

CO

MPO

NE

NTS

MU

ST

BE F

IELD

VE

RIF

IED

AN

D A

RE

THE

RES

PON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRAC

TOR

10 IN

DU

STR

IAL

PAR

KW

AYW

OB

UR

N M

A 0

1801

ENER

GY

SU

PPLY

, IN

C.

2 K

BN

s TK

275

DH

W o

n S

yste

m S

ide

of C

alef

fiG

P2/

16/1

1

Typi

cal b

oile

r zon

es

Squ

ire ta

nkD

HW

sens

or

7

Page 12: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

120V

(ac)

Cla

ss II

Tran

sfor

mer

24V

(ac)

R

L

C

Boi

ler 2

Do n

ot ap

ply p

ower

12

34

56

78

910

1112

1314

1516

1718

1920

2122

2623

2425

5A5A

5A5A

5A5A

5A

Relay

Relay

Relay

Relay

C.A.

/

Aler

t1

23

4

DHW

Powe

rPr

im P1/ P

2L

N275

Boile

rDH

W

/Setp

Dem

Dem

Com

Pr.

Dema

nd

2728

2930

31tN

4Co

mOu

tBo

ilCo

mBr

et/

+Su

pDH

W+

++

+Mo

d1Mo

d2Mo

d3Mo

d4

OAS

S1

DH

W

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OSU

PPLY

.CO

M

THIS

IS O

NLY

A C

ON

CEP

T D

RA

WIN

G. A

LL C

ON

DIT

ION

S AN

D N

ECES

SAR

Y C

OM

PO

NEN

TS M

UST

BE

FIEL

D V

ERIF

IED

AN

D A

RE

TH

E R

ESP

ON

SIBI

LITY

OF

THE

INST

ALLI

NG

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PA

RK

WA

YW

OB

UR

N M

A 0

1801

EN

ER

GY

SU

PP

LY, I

NC

.

2 KB

Ns

TK27

5 D

HW

on

Sys

tem

Sid

e of

Cal

effi

GP

2/16

/11

P3

The

TK27

5 ca

n us

e ei

ther

a D

HW

sen

sor

or a

n A

quas

tat b

ut

not b

oth.

120v

Sup

ply

Boi

ler

Pum

p12

0vS

uppl

yBo

iler

Pum

p

Boi

ler 1

Boile

r 2

* N

ote:

Boi

ler p

umps

mus

t be

pow

ered

out

of

Loch

inva

r con

trol.

KB

N08

1-28

6 bo

ilers

hav

e po

wer

ed p

ump

outp

uts.

KB

N40

0 an

d la

rger

boi

lers

hav

e “d

ry” p

ump

cont

acts

and

mus

t be

pow

ered

.

Boi

ler 1

End

sw

itch

or

ther

mos

tat h

eat c

all

Boi

ler 1Boi

ler 2

N

Loch

inva

r pro

gram

min

g:P

aram

eter

Set

ting

Tekm

ar p

rogr

amm

ing:

Boi

ler M

axim

um

Mod

ulat

ion

Set

ting

in

Adj

ust M

enu

Set

to 9

.8V

8

Page 13: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

H3

54

N/O4

N/C

6 N/O

NN/

C6

SR50

11 Z

ONE

SWIT

CHIN

G RE

LAY

120 V

ACIN

PUT

TT

COM

WR

24 VAC

LN

T

Boile

r

MIX

P

UM

PP

RIM

AR

Y

PU

MPP1

P2

STA

DLE

R

Vie

ga

P1

P2

A o

r B c

an b

e su

pply

from

th

e bo

iler.

Rot

ate

wiri

ng

term

inal

end

of v

alve

ove

r S

uppl

y po

rt. C

mus

t be

“Mix

Sup

ply”

.

C

i-radiant

A B

SU

PPL

Y

SE

NS

OR

(M

IX)

OA

S

BOIL

ER

OUTD

OOR

RC

SENS

ORCO

MMON

24 V

AC

POW

ER

INPU

T

i-Ser

iesRa

dian

tSU

PPLY

(MIX

)

BA

C

120V

(ac)

Cla

ss II

Tran

sfor

mer

24V

(ac)

R

NL

C

The

Boi

ler S

enso

r is

used

for

boile

r pro

tect

ion

and

goes

on

the

boile

r ret

urn

pipi

ng.

This

sen

sor

can

be le

ft ou

t if t

he a

rea

of

radi

ant i

s sm

all r

elat

ive

to th

e ov

eral

l cap

acity

of t

he b

oile

r or i

f th

e bo

iler d

oes

not n

eed

prot

ectio

n.

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT

DR

AW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ES

SA

RY

CO

MP

ON

EN

TS M

US

T BE

FIE

LD V

ERIF

IED

AN

D A

RE

TH

E R

ES

PON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRA

CTO

R

10 IN

DU

STR

IAL

PAR

KW

AY

WO

BUR

N M

A 0

1801

EN

ER

GY

SU

PP

LY, I

NC

.

i-Ser

ies

3-w

ay v

alve

pi

ping

/wiri

ngN

LC3.

07.0

9

9

Page 14: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

EX

ISTI

NG

RE

TUR

NS

S1 =

MIX

SU

PPLY

SEN

SO

R

S2 =

OU

TDO

OR

SE

NSO

R

BA

LL

VA

LVE

PU

MP

ZON

EV

ALV

E

3 W

AYV

ALV

E

4 W

AYV

ALV

E

SPR

ING

CH

EC

K

781-

272-

0020

FA

X 7

81-2

72-0

514

W

WW

.CAP

CO

SU

PPL

Y.C

OM

THIS

IS O

NLY

A C

ON

CE

PT

DR

AW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ES

SA

RY

CO

MP

ON

EN

TS M

US

T B

E F

IELD

VE

RIF

IED

AN

D A

RE

TH

E R

ES

PO

NS

IBIL

ITY

OF

THE

INS

TALL

ING

CO

NTR

AC

TOR

10 In

dust

rial P

arkw

ayW

obur

n, M

A

ENER

GY

SU

PPLY

, IN

C.

TK36

0B

asic

Rad

iant

Add

NLC

1.04

.07

NE

W R

AD

IAN

T P

UM

P

NE

W S

YS

TEM

PU

MP

P1

P2

20V

(ac)

Cla

ss II

Tran

sfor

mer

24V

(ac)

R

NL

C

S1

P2

RW

Rel

ay B

ox E

nd S

witc

h or

T-

stat

Boile

r1

32

Com C

Opn

Cls

MV

EX

ISTI

NG

SU

PP

LIE

S

S1 S2

P1

10A

10A

360

1213

1415

1617

18

Do n

ot ap

ply p

ower

UnO

Com

Mix

Boil

Com

Out

Indr

Sw

12

46

Mixin

g

Dema

nd

Powe

r

LN

Sys

Pmp

N

35

78

910

11

Powe

red O

utput

Boile

rR

RC

Opn

Cls

Mix

ing

Val

ve

10

Page 15: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

© 2010 D 402 - 09/10

Description: The House Control 402 operates a modulating boiler with indirect Domestic Hot Water. Mixing is performed with a three-way floating action mixing valve, which supplies a reset water temperature to four mix temperature hydronic zones. Two boiler water temperature zones shown are operated by a Wiring Center through the tN4 Boil Expansion terminals.

Mix

Boil

DHW

(P3)

(P1)

(P2)

115 V (ac)NL G

to pump grounds

L

Back of House Control 402

Strip wires1/2 inch (13 mm).Installed wires arenot removable.12-18 AWG

RC

LN

Com

Open

Close

ExpansiontN4 Boil

CtN4

ModulatingBoiler

—+

ExpansiontN4 Mix

CtN4

(blue)

(red)

(black)

(black)

(black)

1

313

Menu

House Control 402

Item

+

Mix

ComBoil

Out

DHW

VlvC VlvC VlvCZone 3Zone 1 Zone 2 Zone 4

Made in Canada

VlvC

Com

Zone 1

H8007B

Zone 2 Zone 3 Zone 4tN2 tN2 tN2 tN2 tN2 tN2 tN2 tN2 C

Floating ActionClsOpn

Sensors - No PowerCall

Call

tN4

tN4

CC

Mod

dc/

mA

Boil E

xp.

Mix

Exp.

SetpointDHW

Use at least 167°F(75°C) conductorsRC

Input Power

Stag

e 2

Stag

e 1

Boil System Pump

Mix System Pump

DHW Pump

VariableSpeed Pump

Pump Power L

402070

313

Single Boiler, 2 Boiler Zones, DHW, 3 Way Mix, 4 Mix Zones A402-2

S3

S1 S2

S4

24 V (ac)Transformer 009

Zone Valves (Z1 to Z4)

DHW Sensor (S4)

Boiler Sensor (S1)

Mix Sensor (S2)

tekmarNet®2 Thermostats

Outdoor Sensor

(S3)

tekmarNet®4Expansion to

Wiring Centers,Timers, or

User Switch

tekmarNet®2 ThermostatstekmarNet®2 Thermostats

P1

P2

P3

Z1 Z2 Z3 Z4

11

Page 16: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

1 tN2

tN2

527 2

1 tN2

tN2

527 2

1 tN2

tN2

527 2

1 tN2

tN2

527 2

Cooli

ngRcY

G

12

Rc3Y4

5 GtN

2tN

2

24V(

ac)

2A53

01 tN

2tN

2

527 2

423

Pum

pPrim

ary N

8182

5051

Stag

e 1/

Boil E

nbl

5253

Stag

e 2/

5455

Mod1

(dc)

+

Setp

Enbl

10A

(max

)

5657

Do n

ot ap

ply p

ower

6669

70

DHW

Com

Out

6768

Com

Boil

Pum

pDHW

N

7980

5859

Boile

r

C1

6061

CtN

4

6263

6465

C3tN

4-

+-

Mod2

(dc)

tN4

C2tN

4

12

3

7576

Dema

nd

DHW

7778

Dema

nd

Setpo

int

1 VA

7172

DHW

7374

24 V

(ac)

Vlv

RC

C

8 VA

DHW

BSOA

STo

0-10

on

boile

rs

P3

Cooli

ngRc

YG

12

Rc3Y4

5 GtN

2tN

2

24V(

ac)

2A53

0

S1

1 tN2

tN252

8

2S13

S14No

Pow

er

120 V

(ac)

Cla

ss 2

Tran

sfor

mer

24V

(a

c)C

NLR

MM

1314

151

2Zn

4 Co

ol Fa

n

RcG

YtN

4C

56

tN2

tN2

Zone

1

N

334

3

Pmp

LPu

mp

Zn G

rp

1716

18Zo

ne 1

2122

2423

2526

2728

Zone

2Zo

ne 3

Zone

4

C / N

R / LZone

Pow

er2019

tN4 E

xpan

sion

R

4

Input

Powe

r

78

tN2

tN2

Zone

2

910

tN2

tN2

Zone

3

1112

tN2

tN2

Zone

4

Vlv/P

mp

C / N

Vlv/P

mp

C / N

Vlv/P

mp

C / N

Vlv/P

mp

C / N

Cool

& Fa

n Re

lay R

ating

:24

V (a

c) 2A

5VA

Max.

Zone

Rela

ys: 1

15V(

ac) 5

A

B1B

2

MM

MMMM

MM

1 tN4

C

033 2

3 R

45

Relay

441

12

35

6R

CtN

4Co

mMi

x

4 Pmp

MS44

11

23

56

RC

tN4

Com

Mix

4 Pmp

MS

313

tN2 T

herm

ostat

s only

24Va

c2A

Zone

Valv

e rela

ys: 2

4V 2A

tN2

tN2

Zone

1

tN2

tN2

Zone

2

tN2

tN2

Zone

3

tN2

tN2

Zone

4

tN4

C

Expa

nsion

End

Switc

hX

X

Input

24V

Powe

rR

CZo

ne 1 Vlv

CZo

ne 2 Vlv

CZo

ne 3 Vlv

CZo

ne 4 Vlv

C

R

Com

Out

No P

ower

Zone

Gro

upPu

mp D

ips

Zone

1Zo

ne 2

Zone

3Zo

ne 4

1 2 3 4

Off O

n

LZGP

Powe

rPm

p

Zone

Grou

p

Rear

of c

ontro

l; Max

.5A

To on

/ off

boile

rsB1

B2

Tran

sfor

mer

siz

e ba

sed

on

conn

ecte

d lo

ad

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CAP

CO

SUP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CEP

T D

RA

WIN

G. A

LL C

ON

DIT

ION

S AN

D N

ECES

SAR

Y C

OM

PO

NEN

TS M

UST

BE

FIE

LD V

ERIF

IED

AN

D A

RE

TH

E R

ESP

ON

SIBI

LITY

OF

THE

INST

ALLI

NG

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PAR

KW

AYW

OBU

RN

MA

0180

1

CA

PC

EN

ER

GY

SU

PPL

Y, I

NC

.OTe

kmar

TN

2/TN

41.

31.1

3G

P

12

Page 17: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT

DR

AW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ESS

ARY

CO

MP

ON

EN

TS M

US

T B

E F

IELD

VE

RIF

IED

AN

D A

RE

TH

E R

ESP

ON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRA

CTO

R

10 IN

DU

STR

IAL

PA

RK

WA

YW

OB

UR

N M

A 0

1801

EN

ER

GY

SU

PPLY

, IN

C.

040

34

tN2

Com

no P

ower

120V AC

NLC

6.1

0.08

664

Sno

wm

elt

with

Tek

mar

040

P3

Mix R

eturn

Outdo

or

Sla

b

1 Com C

2 Opn

3 Cls

4 Opn

limit

5 Cls

limit

6 Aux

Sw

7 Aux

Sw 741

M

120VAC

R24V (AC)

C

M

Boile

rBo

iler

Mix S

upply

Mix S

upply

Mix R

eturn

Boile

r

Boile

r Sup

ply

664

2.4A

5A5A

5A5A

5A5A

67

89

1011

1213

1415

1617

18

Red

Blk /

Blu

Yel

Brn /

Slab

Com

tN2

Mix

Mix

Com

Boil

Out

Com

Slab

1Su

pRe

t2

1920

2122

2324

2526

2730

Com

Dema

nd

Stag

eSt

age

Melt/I

dleZn

Com Zn

12Zn

Sys

P1

Powe

r

LN

2829

12

34

5

4-20

mA

+-

Opn/

Var

Pwr

Cls

Mix

21

1 kma

x

P3

P2

P1

Tekm

ar 0

90S

now

/Ice

Sen

sor

Boi

ler P

umps

wire

d di

rect

ly in

to b

oile

rs

13

Page 18: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT

DR

AW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ESS

ARY

CO

MP

ON

EN

TS M

US

T B

E F

IELD

VE

RIF

IED

AN

D A

RE

TH

E R

ESP

ON

SIB

ILIT

Y O

F TH

E IN

STA

LLIN

G C

ON

TRA

CTO

R

10 IN

DU

STR

IAL

PA

RK

WA

YW

OB

UR

N M

A 01

801

EN

ER

GY

SU

PPLY

, IN

C.

VA

LVE

1

ZON

E 3

1 2

3

4ZO

NE

1

1 2

3

4ZO

NE

21

2

3 4

T T

ZON

E 3

E S

OO

MN

CC

N

FACTORYINSTALLED

TRANSFORMER

POWER IN

F U S E 3 A

RES

ET

T T

ZON

E 1

T T

ZON

E 2

THR

EE

ZO

NE

ZO

NE

VA

LVE

CO

NTR

OL

T S

TAT

1

T S

TAT

2

T S

TAT

3

PO

WE

R

VA

LVE

2

VA

LVE

3

FACTORYINSTALLED

TRANSFORMER

120

VO

LT C

IRC

ULA

TOR

SZC

ZRX

XE

. S.

POW

ERIN

PU

TZO

NE

6ZO

NE

5ZO

NE

4ZO

NE

3ZO

NE

2ZO

NE

1

SIX

ZO

NE

SW

ITC

HIN

G R

ELA

YW

ITH

OPT

ION

AL

PR

IOR

ITY

FUS

E 1

AM

P

SR

506

-EX

P

T T

ZON

E 1

T T

ZON

E 2

T T

ZON

E 3

T T

ZON

E 4

T T

ZON

E 5

T T

ZON

E 6

PLU

G-IN

CAR

DS

RE

SET

NO

RM

AL

ZON

E 6

PRIO

RIT

Y ON

OFF

24 VAC

MA

STE

R

SLA

VE

PO

WE

RZO

NE

1ZO

NE

2ZO

NE

3ZO

NE

4ZO

NE

5ZO

NE

6

PH

PH

Taco

Zone

Val

veTw

o W

ireZo

ne V

alve

3.3.

10N

LCW

B2B

Pow

er

Pum

p M

odul

e

Rem

ove

jum

per a

nd w

ire

Prim

ary

Pum

p C

onta

ct to

ZC

term

inal

for D

HW

pr

iorit

y an

d W

WS

D.

N

Vie

ssm

ann

WB

2B P

ower

Pum

p M

odul

e

Zone

Pum

ps

Zone

Pum

p

For m

ore

info

rmat

ion

on th

e W

B2B

C

ontro

l, pl

ease

refe

r to

“Qui

ck S

et-u

p G

uide

” in

the

back

or t

his

book

.

14

Page 19: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-

721-

0303

FAX

781

-721

-911

9

WW

W.C

AP

CO

SUP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CEP

T D

RA

WIN

G. A

LL C

ON

DIT

ION

S AN

D N

EC

ESSA

RY

CO

MP

ON

ENTS

MU

ST B

E FI

ELD

VER

IFIE

D

AND

AR

E T

HE

RE

SPO

NSI

BILI

TY O

F TH

E IN

STAL

LIN

G C

ON

TRAC

TOR

10 IN

DU

STR

IAL

PA

RK

WA

YW

OB

UR

N M

A 0

1801

EN

ER

GY

SU

PP

LY, I

NC

.

WB

1BC

OM

BI

11.2

.12

GP

120v

Pow

er s

uppl

y

VIT

OD

EN

SV

IES

SM

AN

N

WB

1Bc

Sys

tem

pum

p

4 pi

pe d

iam

eter

Clo

se s

pace

tee’

s

X2

X3

LN

NL

120V

PM

PX

4

31

24

DH

WR

T

BP12

0vP

ower

supp

ly

34

21

56

X21

Vies

sman

nOu

tdoor

Sens

orV

ALV

E 1

ZON

E

31

2

3 4

ZON

E

11

2

3 4

ZON

E

21

2

3 4

T T

ZON

E 3

E S

OO

MN

CC

N

FACTORYINSTALLED

TRANSFORMER

POWER IN

F U S E 3 A

RE

SET

T T

ZON

E 1

T T

ZON

E 2

THR

EE Z

ON

E Z

ON

E V

ALV

E C

ON

TRO

L

T ST

AT

1

T ST

AT

2

T ST

AT

3

PO

WER

VAL

VE

2

VAL

VE

3

Sys

tem

pum

p

BP

15

Page 20: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

16

Page 21: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

IFVL03 IFVL04

ISEL0387 ISEL0487

ISEL0345 ISEL0445

ISVL031

IFFC04IFFC03

ISCP04ISCP03

ISBS0487ISBS0387

IANS04IANS03Steel Connector Ring needed at each connection

WB1B

19...35111/34

19...35135/41

Vent System diameter 3" 4"

ft./ mBlr mod

Blr mod

7134 769

ISEI0203

ISEI0304

ISVL04112"24"36"72"

ISVL032ISVL033ISVL036

ISVL042ISVL043ISVL046

IASP04IASP03

IFEP03 IFEP04

5

4

1

67 8

2

A

11

12

13

B

3

17

10

9

1

3

2

6

7

8

9

10

11

13

12

14

15

Adaptor 60 to 80 (2" to 3")

Field Supplied

Field Supplied

Adaptor 80 to 100 (3" to 4")

87 Deg Elbow

45 Deg Elbow

Straight Pipe

90 Deg Base Support

Support Cross Spacers

Boiler Vent Adapter Included w/ Boiler

Flex by foot

Adaptor CPVC 80 to 2" 2" x 3" CPVC3" x 4" CPVC

Field Supplied

Wall Plate

Chimney Support

Coupling for Flex

14

Chimney Cap

Flex End Pipe Termination

Combustion air intake material

Maximum Equivalent WB2BLength (EQL) a+b <

-26/35123/37

-26/35150/46

For Vitodens 100-W WB1B Series& 200-W WB2B Series

5

4

ISEI0203

&

ft./ m

IAWPPS05

Included with 90

IANS04

IANS03

Connector Ring needed at each connection

17

Page 22: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

12

Vent System diameter 80 100

ft./ m

Diameter

7189 822

7134 770

IFVL03 IFVL04

ISEL0387 ISEL0487

ISEL0345 ISEL0445

ISVL031

IFFC04IFFC03

ISCP04ISCP03

ISBS0487ISBS0387

ISEI0304

ISVL041ISVL032ISVL033ISVL036

ISVL042ISVL043ISVL046

IFEP03 IFEP04

IANS04

IANS03

Connector Ring needed at each connection

12"

24"

36"72"

7

6

1

89 10

4

A

13

16

14

12

15

B

5

17

12

11

2

For Vitodens 200-W WB2B Series

Vent System diameter 3" 4"

Maximum Equivalent WB2BLength (EQL) a+b <

-45/-6074/23

-45/-60111/34

1 Boiler Vent Adapter Included w/ Boiler

2 Double Pipe Adapter

Flex by foot4

5Adaptor CPVC 80 to 3"

3" x 4" CPVC Field Supplied

6Adaptor 80 to 100 (3" to 4")

87 Deg Elbow

45 Deg Elbow

7

8

Straight Pipe

9 Wall Plate

10 90 Deg Base Support

11 Chimney Support

Steel Connector Ring needed at each connection

12 IANS04IANS03

13 Coupling for Flex

IASP04IASP0314 Support Cross Spacers

15 Chimney Cap

16 Flex End Pipe Termination

B Combustion air intake material Field Supplied

IAWPPS05

Included with 90

-80/-10598/30 ft./ m

7373 253

4"

IFVL04

7134 771

ISEL0487

ISVL041ISVL042ISVL043ISVL046

ISBS0487

IANS04

IFFC04

IASP04

ISCP04

IFEP04

ISEL0445

18

Page 23: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

WILO STRATOS PUMPWITH RIB RELAY

3.07.09NLC

THIS DIAGRAM SHOWS THE STRATOS PUMP WIRED WITH 230V THROUGH A 20AMP RELAY. YOU NEED TO MATCH THE PUMP CALL’S VOLTAGE TO THE RELAY COIL VOLTAGE RATING. IN THIS

EXAMPLE, A PUMP CALL WITH 120V IS SHOWN. THIS WOULD BE THE TYPICAL WIRING WHEN USING A PUMP RELAY BOX. IN THIS APPLICATION, THE PUMP LCD SCREEN POWERS UP AND DOWN WITH

EACH PUMP CALL.

230 VCircuit

L1 L2

120 VacCoil

White/Black

Orange (Common)Orange (N.O.)

White/Black

RIB01S2Relay In a Box

Contacts

Brown (Common)Brown (N.O.)

WILO STRATOSPUMP

Powered Pump Call

Close

Open

Auto

19

Page 24: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

ExternalOff

0-10v dc

DPDual Pump

L1 L2

230v

COIL

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

Powered Pump Call

CONTACTS

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

WILO PUMP WITH EXT OFF MODULE/120V RELAY

12.29.08NLC

WILO STRATOS PUMP

EXTERNAL OFFMODULE

THIS DIAGRAM SHOWS THE STRATOS PUMP WIRED DIRECTLY WITH 230V AND CONTROLLED BY THE “EXTERNAL OFF MODULE”. THIS MODULE ONLY NEEDS A SET OF “DRY CONTACTS” TO

OPERATE THE PUMP. IF THE PUMP CALL IS ALREADY POWERED, AN ISOLATION RELAY IS NEEDED WITH A MATCHING COIL RATING TO THE PUMP CALL’S VOLTAGE RATING. IN THIS EXAMPLE, A

PUMP CALL WITH 120V IS SHOWN. IN THIS APPLICATION, THE LCD SCREEN REMAINS ON EVEN IN PUMP OFF CYCLES.

20

Page 25: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

WILO STRATOS PUMPS USING DUAL PUMP FEATURE

3.07.09NLC

ExternalOff

0-10v dc

DPDual Pump

L1 L2

COIL

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

Powered Pump Call

CONTACTS

WILO STRATOS PUMP(MASTER)

EXTERNAL OFFMODULES

ExternalOff

0-10v dc

DPDual Pump

230v 230vL1L2WILO STRATOS PUMP

(SLAVE)

WHEN PIPING 2 STRATOS PUMPS IN PARALLEL, THE EXTERNAL OFF MODULE ALLOWS FOR DUAL PUMP CONTROL. THE PUMPS CAN BE PROGRAMMED TO BE “MASTER/SLAVE” OR “STANDBY/DUTY”. IN THE MASTER/SLAVE MODE, THE

PUMPS ROTATE EVERY 24 HOURS OF RUN TIME AND IF A PUMP GOES INTO ERROR, THE OTHER PUMPS COMES ON. IN THE STANDBY/DUTY MODE, THE OPERATING PUMP WILL BRING ON THE OTHER PUMP WHENEVER THE LOGIC DETERMINES THAT TWO PUMPS RUNNING AT A LOWER SPEED WOULD USE

LESS WATTS THAN ONLY ONE RUNNING AT A HIGHER SPEED.

21

Page 26: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Closed loop

VFD

To/ From units

S1

L1

COIL

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

Powered Pump CallFrom Controller

CONTACTS

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Honeywell T775M operarting 0-10 Vdc pump

02.08.11GWP

ExternalOff

0-10vdc

DPDual Pump

L2

230v

WILOSTRATOS PUMP

Honeywell T775MDelta-T Control

Return Sensor

24vc

Ground to conduit clamp

-

+

S1

T775M programingMOD 1a. 0-10vdcb. Set Point = 65 Fc. Throttling Range =30F (80F-50F)d. Control Reaction = Coole. Integral Constant = 0 Seconds

Relay 1 a. Set Point = 51F

b. Differential = 1F

c. Control Reaction = Cool

MOD 2a. 0-10vdcb. Set Point = 40 Fc. Throttling Range =30F (55F-35F)

d. Control Reaction = Heate. Integral Constant = 0 Seconds

Relay 2a. Set Point = 49F

b. Differential = 1F

c. Control Reaction = Heat

Settings are suggested starting points. Field testing of system

performance is needed to verify and adjust as needed is required.

22

Page 27: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

P1 P2 LN

MOTOR

THERMAL OVERLOAD

SWITCH

250 Vac1 amp NC contact

FOR 115 VOLT

PUMPS

L1

N

G

P1 P2 LN

MOTOR

THERMAL OVERLOAD

SWITCH

250 Vac1 amp NC contact

FOR 230 VOLT

1 PH PUMPS

L1

L2

G

230 V 1PH115 V 1PH

P1 P2 LN

MOTOR

THERMAL OVERLOAD

SWITCH

250 Vac1 amp NC contact

L1

NG

For internal overload protection add contactor or relay as shown

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Wilo Top S wiring

GP2.17.11

Do Not Apply Power Directly

to P1 P2

23

Page 28: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Using 12" WM2 Cantilever Arms, you can support the weight in lbs. shown in the

chart. The Length measurement is taken from the Slide Nut and threaded rod to the

wall. Smaller hydraulic separators will have less of a distance off of the wall than

larger separators.

** Please use 4 brackets for 3" and larger hydro separators.

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Raywal SupportFor Hydro-separator

3.4.10NLC

Raywal Support System for Hydro Separators

24

Page 29: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Lochinvar WHNBoiler w / front panel

removed for viewing only

¾”

1

1 ¾”

¾”

Add ¾” Tee, Bushing and Auto Vent to get air out

Install ¾” street elbow and nipple then re-install existing Boiler Relief in same upright

position

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

WHNHI-Vent

12.13.12G.P.

Capco Energy Supply recommends the following procedure in order to

facilitate air removal.

Lochinvar WHNBoiler w / front panel

removed for viewing only

Before filling the boiler remove existing boiler relief valve

Test Boiler relief for proper function

From FactoryLochinvar WHN

Air removal

25

Page 30: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

A

SUPPLYBOILER

SETBACKR C

SENSORCOMMON

24 VACPOWER INPUT

iVALVE-S

BC

A

P1

P2

Axi

om M

F-20

0 G

lyco

l Fe

eder

Sno

wm

elt M

anifo

ld

Taco

i-Se

ries

Valv

eS

etpo

int M

odel

SX40

V

Fill

and

Pur

ge P

oint

s

See

Bas

ic S

now

mel

t Wiri

ng o

n th

e ne

xt p

age

for c

ontro

l det

ails

.

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT D

RAW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ES

SAR

Y C

OM

PO

NE

NTS

MU

ST

BE

FIE

LD V

ER

IFIE

D A

ND

AR

E T

HE

RES

PO

NSI

BIL

ITY

OF

THE

INS

TALL

ING

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PAR

KWAY

WO

BU

RN

MA

018

01

EN

ER

GY

SU

PP

LY, I

NC

.

Bas

ic S

now

mel

t/Axi

om3.

07.0

9N

LC

The

Axi

om F

eede

r is

not s

uita

ble

for u

se a

s a

trans

fer p

ump.

Y

ou w

ill n

eed

to fi

ll sy

stem

with

a p

rope

r tra

nsfe

r pum

p be

fore

pu

tting

feed

er in

to u

se.

26

Page 31: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT D

RAW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ES

SAR

Y C

OM

PO

NE

NTS

MU

ST

BE

FIE

LD V

ER

IFIE

D A

ND

AR

E T

HE

RES

PO

NSI

BIL

ITY

OF

THE

INS

TALL

ING

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PAR

KWAY

WO

BU

RN

MA

018

01

EN

ER

GY

SU

PP

LY, I

NC

.

SM

97

Black

White

Yellow

Yel

low

CO

M

RW

24 VAC

TT

NH

34 N/O

4 N/C

6 N/C

6 N/O

5

1 ZO

NE

SW

ITC

HIN

G R

ELA

Y

120

VA

CIN

PU

T

T S

TAT

JUM

PER

SR

501

PO

WER

TIM

ER

24V

12

34

56

7

8ANo

Pow

er15

0On Of

fPWM

C -

R +

Com

N/O

N/C

Sens

orPo

wer

Boi

ler T

T C

onne

ctio

n

Bas

ic S

now

mel

t Wiri

ngM

icha

el D

. Fox

02/2

1/20

07

Bas

ic W

iring

for S

now

mel

t

S1

Pla

ce S

enso

r O

utdo

ors

This

will

ser

ve a

s a

tight

er W

arm

We

ath

er

Sh

ut

Do

wn

than

pr

ovid

ed b

y th

e S

M97

. Set

for 3

4 F

OFF

Circ

uit B

reak

er

Pan

el

P-1

P-2

27

Page 32: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

CONTROLINPUTS

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

2-Stage Heat Wiring Hydronic / Fan-coil

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

2-Stage T-statWiring

10.18.08NLC

2-Stage Thermostat

R Rc W1 W2 Y G

SIX ZONE SWITCHING RELAYWITH OPTIONAL PRIORITY

SR506

INPUT120 VOLT CIRCULATORSPOWERZONE6ZONE5ZONE4ZONE3ZONE2ZONE1ZRZCEND

SWITCHX X

ZONE3ZONE2ZONE1 ZONE4 ZONE5 ZONE6

FUSE 1 AMP

24 VACPOWER

ONOFF

ZONE 6PRIORITY

RWYGC

Typical 1st

Company Fan-coil

P P

FOUR ZONE ZONE VALVE CONTROL WITH OPTIONAL PRIORITYZVC 404-EXP

1 2 3 4ZONE 1

1 2 3 4ZONE 2

1 2 3 4ZONE 3

1 2 3 4ZONE 4

ZONE 1T T

ZONE 2T T

ZONE 3T T

ZONE 4T T

POW

ER IN 1 2 3 4

ZONE 4 RELAYN/O N/CCOM

PUMP

ENDSWB

BOILER

ENDSWA

MODERESET NORMAL

SLAVE

MASTER

POWERCONTROLS

FUSE

7 A

MP M

AX

EXPANSION

PLUG-INCARDS

ONOFF

ZONE 4 PRIORITY

1st Stage Heat Call

2nd Stage Heat Call for hot water flow

Typical wiring where 1st

- Stage heat is hydronic and 2nd - stage heat is

from a fan-coil unit. Thermostat gets it’s 24v from the fan-coil. W1 needs to be isolated

from thermostat voltage because TT on zone control has it’s own

voltage.

Notice W2 goes to W on fan-coil.

28

Page 33: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

2-Stage Thermostat

Rc Rh W2 W1 C Y

CONTROLINPUTS

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

2-Stage Heat Wiring Using 2 Powered Zone Relays

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

2-Stage T-stat WiringWith 2 Zone Boxes

3.4.10NLC

THREE ZONE SWITCHING RELAYWITH OPTIONAL PRIORITY SR503-EXP

FUSE 1 AMP

24 VACPOWER

ONOFF

ZONE 3PRIORITY

RESET NORMALPOWER CONTROL INTERFACE

MASTER

SLAVE

1 2 3 4EXPANSION

PLUG-IN CARDS

ZONE3ZONE2ZONE1

INPUT120 VOLT CIRCULATORSPOWERZONE3ZONE2ZONE1ZRZCEND

SWITCHX X

THREE ZONE ZONE VALVE CONTROL

ZVC 403

1 2 3 4ZONE 1

1 2 3 4ZONE 2

1 2 3 4ZONE 3END

SWITCH

ZONE 1T T

ZONE 2T T

ZONE 3T T

FUSE (5 AMP MAX)

N/O N/CCOM

POW

ER IN

24VC

1ST Stage Heat Call

2nd Stage Heat Call

This example shows a 2-stage thermostat controlling 2 zone boxes with powered TT terminals. Notice the power

for the thermostat and the W1 and W2 come from the right-hand terminal on the 2nd-stage zone box. This

terminal always has power. Also notice the common from the thermostat and the relay coil needs to come back to the common on the transformer that supplied 24v to the

thermostat.

29

Page 34: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

COIL

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

COIL

White/Blue (10 - 30 VAC/DC)

Yellow (Common)Orange (N.O.)

White/Yellow (Common)White/Black (120 VAC)

Blue (N.C.)

RIBU1CRelay In a Box

120vPower in

120vL N

P1

120v

L N

P2

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Isolation RelaysFor Amp Draw over Rating

Allowance

NLC1.25.13

Because the amp rating on the solar pumps are greater than what the relays in the i-Solar control can handle, an isolation

relay is needed for each pump. This allows the control to only cover the amp draw of the relay coil. The contacts on

the relay handle the amp draw of the pumps.

30

Page 35: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Chi

ller

Chi

ller

Gly

col F

eed

Tank

VFD

Bala

ncin

g Va

lve

Dirt

S

epar

ator

Pur

ge

Val

ve

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CA

PC

OS

UP

PLY

.CO

M

THIS

IS O

NLY

A C

ON

CE

PT D

RAW

ING

. ALL

CO

ND

ITIO

NS

AN

D N

EC

ES

SAR

Y C

OM

PO

NE

NTS

MU

ST

BE

FIE

LD V

ER

IFIE

D A

ND

AR

E T

HE

RES

PO

NSI

BIL

ITY

OF

THE

INS

TALL

ING

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PAR

KWAY

WO

BU

RN

MA

018

01

EN

ER

GY

SU

PP

LY, I

NC

.

STA

GIN

GC

ON

TRO

LLE

R

T775

B20

40

C

N.O

.

N.C

.

CN.O

.

N.C

.

CN.O

.

N.C

.

S1 C

24V C

SU

PP

LY T

EM

PS

EN

SO

R

12

34

56

7

8A

No P

ower

150

On OffPWM

C -

R +

Com

N/O

N/C

Sens

orPo

wer

Out

door

Tem

pE

nabl

e/D

isab

le

Set

to##

S1

OAS

SIX

ZONE

ZON

E VA

LVE

CONT

ROL W

ITH

OPTI

ONAL

PRI

ORIT

YZV

C 40

6-EX

P

12

34

ZONE

11

23

4ZO

NE 2

12

34

ZONE

31

23

4ZO

NE 4

12

34

ZONE

51

23

4ZO

NE 6

ZONE

1T

TZO

NE 2

TT

ZONE

3T

TZO

NE 4

TT

ZONE

5T

TZO

NE 6

TT

POWER IN

12

34

ZONE

6 RE

LAY

N/O

N/C

COM

PUMP

ENDS

WB

BOILE

REN

DSW

A

MODE

RESE

TNO

RMAL

SLAV

E

MAST

ER

POW

ERCO

NTRO

LS

FUSE 7 AMP MAX

EXPA

NSIO

N

PLUG

-INCA

RDS

ON OFF

ZONE

6 PR

IORI

TY

ZV1

ZV2

ZV3

Cal

ls fo

r Zon

e V

alve

s

120V

(a

c)

Cla

ss 2

Tran

sfor

mer

24V

(ac)

R

NL

C

To C

hille

r S

tage

1

To C

hille

r S

tage

2

Zone

Val

ve

Wire

d D

irect

ly

Zone

Val

ve

Wire

d th

roug

h A

irhan

dler

Mul

tiple

Chi

ller P

ipin

g an

d S

tagi

ng2.

16.1

0G

P

ZV4

Digital In

S1

Buf

fer T

ank

31

Page 36: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

S o l a

r C o

l l e c

t o r

SX4

0V

SY

STE

M F

ILL

To h

eat z

ones

Exi

stin

g D

HW

Ta

nkS

olar

Sto

rage

Ta

nk

EX

ISTI

NG

HY

DR

ON

IC

SY

STE

M

Col

d In

Hot

Out

S1

S2

Fill

& P

urge

V

alve

781-

721-

0303

FA

X 7

81-7

21-9

119

W

WW

.CAP

CO

SU

PPL

Y.C

OM

THIS

IS O

NLY

A C

ON

CE

PT D

RAW

ING

. ALL

CO

ND

ITIO

NS

AND

NE

CE

SSA

RY

CO

MPO

NE

NTS

MU

ST

BE

FIEL

D V

ER

IFIE

D A

ND

AR

E TH

E R

ESPO

NS

IBIL

ITY

OF

THE

INS

TALL

ING

CO

NTR

ACTO

R

10 IN

DU

STR

IAL

PAR

KW

AYW

OBU

RN

MA

0180

1

EN

ERG

Y S

UP

PLY

, IN

C.

CA

PC

OTh

erm

al S

olar

R

etro

fit2.

21.0

8N

LC

S1

S2

This

exa

mpl

e sh

ows

a hy

dron

ic s

yste

m h

eatin

g th

e ex

istin

g do

mes

tic h

ot w

ater

. Th

e re

trofit

ap

plic

atio

n w

ould

wor

k w

ith a

ny ty

pe o

f DH

W

heat

er.

It co

uld

be e

lect

ric, o

il-fir

ed o

r gas

-fire

d.

The

Sol

ar p

ortio

n of

wor

k w

ould

rem

ain

the

sam

e.

The

Hot

Out

of t

he S

olar

Tan

k w

ould

be

the

Col

d In

on

the

exis

ting

tank

.

32

Page 37: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Dom

esticWater

Hot

side

Boilerwater

180*Fto

160*F

Coldside

Dom

estic

water

40*F

to140*F

Mod

elNo.of

Plates

BTU/h

Conn

ectio

ns

Hot

Side

ColdSide

Hot

Side

ColdSide

9.3

1.8

LB31

2020

90,000

1"FN

PT3.06

0.22

10.0

2.0

LB31

2020

100,000

1"FN

PT3.71

0.27

12.9

2.5

LB31

2020

125,000

1"FN

PT6.5

0.4

14.4

2.8

LB31

2020

140,000

1"FN

PT8.1

0.5

15.5

3.0

LB31

2020

150,000

1"FN

PT7.85

0.57

25.7

5.0

LB31

4040

250,000

1"FN

PT6.16

0.39

30.9

6.0

LB31

4040

300,000

1"FN

PT8.62

0.54

361

70

LB31

6060

350000

1"FN

PT629

036

Flow

(gpm

)Pressure

Drop(psi)

36.1

7.0

LB31

6060

350,00

01"

FNPT

6.29

0.36

46.4

9.0

LB31

8080

400,00

01"

FNPT

6.99

0.38

Allun

itswith

platedimen

sion

sof

5"x12

"

Dim

.A12

Dim

.B5

Dim

.C9.8

Dim

.D2.8

Dim

.F0.49

+0.09N

PArea(sq.ft.)

0.34

NP=nu

mbe

rof

plates

Dim

ension

s(in

.)

33

Page 38: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Radian

tFloor

Hot

side

Boilerwater

180*Fto

160*F

Coldside

Radiantfloor

water

100*Fto

120*F

Mod

elNo.of

Plates

BTU/h

Conn

ectio

ns

Hot

Side

ColdSide

Hot

Side

ColdSide

9.3

9.1

LB31

2020

90,000

1"FN

PT3.06

4.04

10.3

10.1

LB31

2020

100,00

01"

FNPT

3.71

4.89

12.9

12.6

LB31

2020

125,00

01"

FNPT

5.57

7.34

20.6

20.2

LB31

4040

200,00

01"

FNPT

4.09

4.77

30.9

30.3

LB31

6060

300,00

01"

FNPT

4.72

5.24

41.2

40.4

LB31

8080

400,00

01"

FNPT

5.6

6.04

Allun

itswith

platedimen

sion

sof

5"x12

"

Flow

(gpm

)Pressure

Drop(psi)

Allun

itswith

platedimen

sion

sof

5x12

Dim

.A12

Dim

.B5

Dim

.C9.8

Dim

.D2.8

Dim

.F0.49

+0.09N

PArea(sq.ft.)

0.34

NP=nu

mbe

rof

plates

Dim

ension

s(in

.)

34

Page 39: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Snow

Melt

Hot

side

Boilerwater

180*Fto

160*F

Coldside

40%Ethylene

glycol

100*Fto

130*F

Mod

elNo.of

Plates

BTU/h

Conn

ectio

ns

Hot

Side

ColdSide

Hot

Side

ColdSide

6.2

6.7

LB31

2020

90,000

1"FN

PT1.47

2.83

6.9

7.4

LB31

2020

100,00

01"

FNPT

1.78

3.43

8.6

9.3

LB31

2020

125,00

01"

FNPT

2.68

5.15

9.6

10.4

LB31

2020

140,00

01"

FNPT

3.29

6.33

17.2

18.6

LB31

4040

250,00

01"

FNPT

2.94

4.96

24.1

26.0

LB31

6060

350,00

01"

FNPT

2.97

4.72

275

297

LB31

8080

40000

01"

FNPT

262

400

Flow

(gpm

)Pressure

Drop(psi)

27.5

29.7

LB31

8080

400,00

01"

FNPT

2.62

4.00

Allun

itswith

platedimen

sion

sof

5"x12

"

Dim

.A12

Dim

.B5

Dim

.C9.8

Dim

.D2.8

Dim

.F0.49

+0.09N

PArea(sq.ft.)

0.34

NP=nu

mbe

rof

plates

Dim

ension

s(in

.)

35

Page 40: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Pool

/Spa

Hea

ting

MLi

neSh

ella

ndTu

beH

XHot

side

180*Fto

160*F

Coldside

85*F

to10

0*F

PoolCapacity

BoilerOutpu

t1*F/hr

HeatR

ise

BoilerOutpu

t2*F/hr

HeatR

ise

Gallons

Btu/hr

Mod

elHot

Side

ColdSide

Hot

Side

ColdSide

Btu/hr

Mod

elHot

Side

ColdSide

Hot

Side

ColdSide

16,000

133,00

0M

180

13.3

17.7

0.14

0.72

266,00

0M

300

26.6

35.5

0.86

0.88

18,000

150,00

0M

180

1520

.00.17

0.92

300,00

0M

300

3040

.01.07

1.11

20,000

167,00

0M

180

16.7

22.3

0.21

1.14

334,00

0M

500

33.4

44.5

2.28

2.37

32,000

267,00

0M

300

26.7

35.6

0.86

0.88

534,00

02x

M30

053

.471

.20.86

0.88

34,000

284,00

0M

300

28.4

37.9

0.97

0.99

568,00

02x

M30

056

.875

.70.97

0.99

36,000

300,00

0M

300

3040

.01.07

1.11

600,00

02x

M30

060

80.0

1.07

1.11

38,000

317,00

0M

500

31.7

42.3

2.07

2.14

634,00

02x

M50

063

.484

.52.07

2.14

40,000

334,00

0M

500

33.4

44.5

2.28

2.37

668,00

02x

M50

066

.889

.12.28

2.37

42,000

350,00

0M

500

3546

.72.49

2.61

700,00

02x

M50

070

93.3

2.49

2.61

44,000

368,00

0M

500

36.8

49.1

2.73

2.88

736,00

02x

M50

073

.698

.12.73

2.88

App

lications

requ

iringtw

ohe

atexchangersshallbepipe

dinparallel

PoolWater

(coldside

thru

shell)

Mod

elM

180

M30

0HTA

(sq.ft.)

4.7

9.0

Length

(in.)

15.3

25.1

ShellO

D(in

.)4.1

4.1

Tube

Conn

.1"

NPT

1"NPT

BoilerWater

(hot

side

thru

tube

s)ShellCon

n.1.5"

NPT

1.5"

NPT

Max

Pressure

(psi)

150

150

Max

Temp(F)

406F

406F

(Boilerwater

thru

tube

side

)(Poo

lwater

thru

shellside)

406F

16.8

Pressure

Drop(psi)

1.5"

NPT

150

Flow

(GPM

)Pressure

Drop(psi)

M50

0

42.9

4.1

1"NPT

Flow

(GPM

)

36

Page 41: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

37

Page 42: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

38

Page 43: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Data subject to change without notice | 01.2011 BOSCH THERMOTECHNOLOGY CORPORATION

THERM Tankless Water Heater Applications Manual10 |

0

1

2

3

4

5

6

7

8

520 PN/HN

330 PN

10 20 30 40 50 60 70 80 90Degree rise (°F)

GPM

Gas Appliance Sizing Chart

940 ES/ESO

C 1050 ES

9

10

C 1210 ES/ESC

11

830 ES

660 EF/EFO

12

• Flows above 10 GPM assume installation of a mixing valve to help mitigate pressure drop in the water heater and plumbing system

Required flow rate of fixtures in GPM

BOSCH Tankless Water Heater

Temperature Rise desired from incoming street water temperature to fixture temperature.

39

Page 44: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Flow rate adjustment

The flow rate is adjusted as follows:

Complete closing and opening of the valve

The valve can be completely closed and opened. A slot on thecontrol stem indicates the valve position. When the control stem isturned fully clockwise(the slot is perpendicularto the axis of the valve),the valve is fully closed(A). When the controlstem is turned fullycounter-clockwise (theslot is parallel to the axisof the valve), the valveis fully open (B).

Insulation

The 132 series balancing valveis supplied with a pre-formedinsulating shell. This systemensures perfect thermalinsulation and keeps out watervapor from the environment.Additionally, this type ofinsulation is ideal in cold watercircuits as it preventscondensation from forming onthe surface of the valve body.

100

0.1

1

0.2

0.3

0.5

200

500

Δp (psi)

G(l/

h) (

gpm

)10

2

3

5

20

0.1

1

0.2

0.3

0.5

(psi) (bar)

10

2

3

5

20

0.01

0.1

0.02

0.03

0.05

1.0

0.2

0.3

0.5

4

0.4 0.4

4

0.04

0.4

1000

2000

5000

10000

20000

10.2

0.5

2 5 10

20

50

100

200

50

1/2”

3/4”

1” 1 1/

4”

1 1/

2”

2”

7

6

5

4

3

2

7

6

5

4

3

2

765432

765432

132 series 132 series

5D

Pump

10D

A.With the aid of the flow rate indicator (1), mark the desired flow rate.

C.While holding the bypass valve open, use a wrench to turn thevalve control stem (4) to adjust the flow rate. The resulting flowrate is indicated by the metal ball (5) that slides up and downinside a transparent channel (6) marked by a graduated scale in gpm.

D.Once the flow rate is properly adjusted, release the operating ring (2) of the bypass valve. The valve will automatically return to the closed position by means of an internal spring.

13

4

2

5

6

A B

Completely closed Completely open

Installation

Install the balancing valve in a location that ensures free access tothe flow meter shutoff valve, control stem and flow rate indicator. Toensure accurate flow measurement, straight sections of pipeinstalled as shown is recommended.

The valve can be installed in any position with respect to the flowdirection shown on the valve body. Additionally, the valve can beinstalled either horizontally or vertically.

Hydraulic characteristics at 100% open

B.Use the operating ring (2) toopen the bypass valve. Thisallows fluid to flow throughthe flow meter (3). Thebypass valve is automaticallyclosed under normaloperating conditions.

Code Connection Flow rate (GPM) Cv132432A 1/2” NPT 1/2 – 1 3/4 1.0132552A 3/4” NPT 2.0 – 7.0 6.3132662A 1” NPT 3.0 – 10.0 8.3132772A 1 1/4” NPT 5.0 – 19.0 15.2132882A 1 1/2” NPT 8.0 – 32.0 32.3132992A 2” NPT 12.0 – 50.0 53.7

Caleffi 132 Balance Valve

40

Page 45: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

sbLkPnoitpircseDedoC5.211snoinu TPN "1A6008455.211snoinu taews '1A6908455.611snoinu TPN "4/1-1A7008455.611snoinu taews "4/1-1A7908451.521snoinu TPN "2/1-1A8008451.721snoinu TPN "2A900845

Size 2 2 1/2" 3 4" 5" 6" 8" 10" 12"GPM 40 80 124 247 330 485 792 1320 1850Vol. 4.0 4.0 8.0 8.0 22.5 23.2 95 175 255

sbLkPnoitpircseDedoC0.571degnalf "2A2508455.181degnalf "2/1-2A2608454.2111degnalf "3A2808450.7111degnalf "4A201845

sbLkPnoitpircseDedoCsbLkPnoitpircseDedoC0.571EMSA degnalf "2A250845AN0.0221EMSA degnalf "5A021845AN5.181EMSA degnalf "2/1-2A260845AN0.1321EMSA degnalf "6A051845AN4.2111EMSA degnalf "3A280845AN0.0251EMSA degnalf "8A002845AN0.7111EMSA degnalf "4A201845AN0.5271EMSA degnalf "01A052845AN001,11EMSA degnalf "21A003845AN

548 tech brochure 01076

*NA prefix indicates ASME tagged and registered with the National Board of Boiler and Pressure Vessel Inspectors.

Hydro SeparatorHydronic separator. Epoxy resin coated steel body. With pre-formed insulation. ANSI flanged connections. Complete with: automatic air vent valve with shutoff valve, drain valve.Max. working pressure: 150 psi.Working temperature range: 32 - 220°F.Working temp. without insulation: 32 - 250°F. Hydro Separator ASME

FLOW CAPACITY - FLANGED CONNECTIONS

3.51.30.7

Hydronic separator. Epoxy resin coated steel body. Without insulation. Complete with: automatic air vent valve with shutoff valve, drain valve.ANSI flanged connections.Max. working pressure: 150 psi.Working temperature range: 32 - 250°F.ASME tagged and registered with the National Board of Boiler and Pressure Vessel Inspectors.

Hydronic Separatortech brochure 01076

tech brochure 01076

548Hydro SeparatorHydronic separator. Epoxy resin coated steel body. With pre-formed insulation. Sweat & threaded union connections. Complete with: automatic air vent valve with automatic check valve, drain valve.Max. working pressure: 150 psi.Working temperature range: 32 - 210°F.Working temp. without insulation: 32 - 250°F.

548

Maximum recommended flow rates in GPM and volume capacity in gallons.

FLOW CAPACITY - UNION CONNECTIONS

The hydronic separator creates a zone with a low pressure loss, which enables the primary and secondary circuits connected to it to be hydraulically independent of each other; the flow in one circuit does not create a flow in the other.

2"37

1 1/2"26

1 1/4"18

1"110.5

SizeGPM

Volume

41

Page 46: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

sbLkPnoitpircseDedoC8.31TPN"4/3A5026458.31TPN"1A6026459.41TPN"4/1-1A7026459.41TPN"2/1-1A8026455.51TPN"2A902645

sbLkPnoitpircseDedoC8.31taews"1A8226458.31taews"4/1-1A532645

Size 3/4" 1' 1 1/4" 1 1/2"GPM 6.0 9.3 15.3 23.9

Cv 18.8 32.6 56.6 73.3

tech brochure 01137

Dirt separator. Brass body.1/2" NPT top thread with plug. NPT connections.Max. working pressure: 150 psi.Working temperature range: 250°F.

5462

5462

36.0

81.0

tech brochure 01137

Particle separation capacity - Dirt separator efficiency

Low head losses and performance maintained over time

The separating action performed by the dirt separator is based on using the internal element with concentric surfaces in place of the ordinary filter. The element, by its nature, offers little resistance to the flow of medium while ensuring separation.This occurs due to the particles colliding with the concentric surfaces and then settling, and not by filtration; an action by which the filter, over time, gets progressively clogged by the sludge it removes. All this is to the benefit of performance; that is the high capacity to separate impurities and the low head losses that remain unaltered over time.

FLOW CAPACITY

Dirt separator. Brass body.1/2" NPT top thread with plug. Sweat connections.Max. working pressure: 150 psi.Working temperature range: 250°F.

2"

Geometric structure and large dirt collection chamber

The geometrical structure of DIRTCAL means that inside it the velocity is reduced to help separate the particles of impurities. The dirt collection chamber has the following features:- It is located at the bottom of the device at such a distance from the connections that the collected impurities are not affected by the swirl of the flow through the screen.- It has enough capacity to increase the amount of sludge stored and therefore decreases the frequency of emptying/discharging it (on the contrary to filters that need to be frequently cleaned).- It is easily inspected by unscrewing it from the valve body for servicing the internal element in the event of an obstruction from large debris.

1000

Efficiency50 passages ( 2 f/s)

502010

40

20

0

60

80

100

Efficiency (%)Efficiency50 passages ( 4 f/s)

Mic

ropa

rticl

e siz

e(

m)

0 5 16 35 63 105

150

250

210

500

DIRTCALWORKING ZONE

CARTRIDGE FILTERS

SPECIAL STRAINERS

Y-STRAINERS

Separated quantityInitial quantity

.100%( )

42

Page 47: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

The

mal

e

part

INN

OFL

UE®

FLEX

IBLE

Con

tent

s of

the

kit

Inst

alla

tion

Mou

ntin

g in

stru

ctio

n fo

r ki

t |

Hor

izon

tal c

him

ney

conn

ectio

n

IFC

K03

25 /

IFC

K03

35 /

IFC

K04

25 /

IFC

K04

35

Cent

roth

erm

Eco

Sys

tem

s, L

LC •

418

Sou

th P

earl

Str

eet,

Alb

any,

NY

1220

2 •

518

434

-340

0 •

Fax

518

618

-316

6 •

info

@ce

ntro

ther

m.u

s.co

m •

ww

w.c

entr

othe

rm.u

s.co

m

Mou

nt m

etal

sec

tion

Bas

e S

uppo

rt

in b

ase

of c

him

ney.

1 2 3 4 5 6 7 8 9

Fit C

him

ney

Cove

r ove

r Fle

x Pi

pe

and

atta

ch to

chi

mne

y w

ith

mas

onry

scr

ews

prov

ided

.

Sna

p on

Fle

x En

d Pi

pe L

ocki

ng

Ring

to F

lex

Pipe

.

Cut F

lex

Pipe

at t

op o

f Fle

x En

d Pi

pe L

ocki

ng R

ing

at re

cess

in

corr

ugat

ions

.

Inse

rt F

lex

End

Pipe

into

Chi

mne

y Co

ver,

scr

ewin

g in

tigh

t.

Atta

ch to

p of

Chi

mne

y Co

ver.

Inst

all V

ent L

engt

h (s

old

sepa

rate

ly) w

ith

Conn

ecto

r int

o

Bas

e S

uppo

rt.

Fix

the

Wal

l Pla

te (s

old

sepa

rate

ly).

Cont

inue

wit

h ri

gid

wal

l Ven

t Len

gths

and

Elb

ows

to a

pplia

nce.

Cut t

he F

lex

Pipe

(jus

t und

er m

ale

part

) at t

he le

ngth

of t

he

chim

ney.

Att

ach

spac

ers.

Pul

l Fle

x Ve

nt L

engt

h th

roug

h ch

imne

y in

sert

ing

mal

e en

d in

to B

ase

Sup

port

. Ens

ure

that

Con

nect

or

is in

stal

led.

Conn

ecto

r

Flex

ible

ven

t le

ngth

(25'

or

35')

Spa

cer

Cent

roci

n

Bas

e su

ppor

t

Flex

end

pip

ew

ith

lock

ing

ring

Chim

ney

cove

r w

ith

cap

Upd

ated

: 11/

17/1

0

43

Page 48: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

www.grundfos.us

CanadaGRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: (905) 829-9533 Telefax: (905) 829-9512

U.S.A.GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: (913) 227-3400 Telefax: (913) 227-3500

MexicoBombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoC.P. 66600 Apodaca, N.L. Mexico Phone: 011-52-81-8144 4000 Telefax: 011-52-81-8144 4010

L-U

P-S

L-0

21

3/1

2 (

US)

– How Traditional Hot Water Recirculation Works

Pump Technical Data:Flow Range: 0 to 3.5 U.S. GPM

Head Range: 1 to 5 U.S. Feet

Motor: 25W, Single Phase, 115V

Min. Fluid Temperature: 36°F (2°C)

Max. Fluid Temperature: 203°F (95°C)

Max. Working Pressure: 145 PSI

Standard Features: 5ft. line-cord w/plug

Optional Features: Timer, Aquastat

2

2 pump:

THE GRUNDFOS

UP10-16BU ATLC

1 pipes:

Performance Curve:

IsolationValve

Timer

Check Valve1

ModelsMaterial Number

1/2” Sweat

1/2” F NPT

1 1/4” Union

LineCord

Timer AquastatCheckValve

Isolation Valve

UP10-16B5 LC 97525905

UP10-16B5 TLC 97525907

UP10-16B5 ATLC 97525908

UP10-16BN5 LC 96433897

UP10-16BN5 TLC 96433898

UP10-16BN5 ATLC 96433899

UP10-16BU ATLC 97525922

GRUNDFOS Recirc Pump

44

Page 49: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

www.grundfos.com

Being responsible is our foundation

Thinking ahead makes it possible

Innovation is the essence

L-A

L-SL

-00

1 4

/09

(U

S)

Technical Data:

Flow Range:

Head Range: 0 to 19 Feet

Motor: 1X115V

Min. Fluid Temperature:

Max. Fluid Temperature:

Max. Working Pressure: 150 PSI

Watts:

Amps:

Dimensional Drawing:

A B C D E F G

0 2 4 6 8 10 12 14 16 18 20 22 24Q [US GPM]

02468

1012141618[ft]H

Performance Curve:

Orange: AUTOADAPT™ Range

Red:

Black:

Description Part Number

CanadaGRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: (905) 829-9533 Telefax: (905) 829-9512

U.S.A.GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: (913) 227-3400 Telefax: (913) 227-3500

MexicoBombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoC.P. 66600 Apodaca, N.L. Mexico Phone: 011-52-81-8144 4000 Telefax: 011-52-81-8144 4010

GRUNDFOS ALPHA

45

Page 50: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

GRUNDFOS MAGNA 32-60

46

Page 51: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Technical Data:

Flow Range:

Head Range:

Motor:

Min. Fluid Temperature: °C)

Max. Fluid Temperature:

Max. Working Pressure:

Watts:

Max. Amps:

Dimensional Drawing:

Product Offering:

A B C D E F G H I J

Performance Curve:

ADAPT™ Range

Model Description Part Number

MAGNA 32-100 Cast iron flange with line cord

Geni Module External Control/Bus Communicaton for MAGNA 32-100

Relay Module Signal Relay for MAGNA 32-100

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

www.grundfos.com

CanadaGRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: (905) 829-9533 Telefax: (905) 829-9512

U.S.A.GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: (913) 227-3400 Telefax: (913) 227-3500

MexicoBombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoC.P. 66600 Apodaca, N.L. Mexico Phone: 011-52-81-8144 4000 Telefax: 011-52-81-8144 4010

L-M

AG

-SL-

02

1/1

1 (

US)

C

D

A

E

B

J

F

GI

H

47

Page 52: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

TECHNICAL DATA GRUNDFOS SERIES UP

UPS 15-58FC/FRC SUPERBRUTE

Flow range: 0 - 17.5 U.S. GPMHead range: 0 - 19 FEETMotors: 2 Pole, Single PhaseMaximum fluid temperature: 230°F (110°C)Min. fluid temperature: 36°F (2°C)Maximum working pressure: 145 PSI

0

2

4

6

8

10

12

14

16

18

20

0 2 4 6 8 10 12 14 16 18

Flow (GPM)

Hea

d (f

t.)

HI

MED

LOW

Without Check Valve

With Check Valve

UPS15-58FC/FRC AMPS WATTS HP CAPACITORSpd. 3 0.75 87 1/25 10mF/180VSpd. 2 0.66 80 1/25 10mF/180VSpd. 1 0.55 60 1/25 10mF/180V

115V

A

D F

E

BC

48

Page 53: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

GENERAL DATA GRUNDFOS SERIES UP

UPS 26-99FC/BFC SUPERBRUTE

Flow range: 0 - 34 U.S. GPMHead range: 0 - 30 FEETMotors: 2 Pole, Single PhaseMaximum fluid temperature: 230°F (110°C)Min. fluid temperature: 36°F (2°C)Maximum working pressure: 145 PSI

0

5

10

15

20

25

30

0 5 10 15 20 25 30 35

Flow (GPM)

Hea

d (f

t.)

HI

MED

LOW

Without Check Valve

With Check Valve

MODEL VOLTS AMPS WATTS HP CAPACITORSpd. 3 1.8 197 1/6 20mF/180VSpd. 2 1.5 179 1/6 20mF/180VSpd. 1 1.3 150 1/6 20mF/180VSpd. 3 0.9 196 1/6 5mF/400VSpd. 2 0.8 179 1/6 5mF/400VSpd. 1 0.7 150 1/6 5mF/400V

115V

230V

Model Type A B C D E F Connection Type and Size

Approximate Shipping Wt.

(lbs)UPS26-99FC/BFC 6 1/2 6 4 7/8 3 1/2 3 7/16 3 5/32 GF 15/26 Flange - (2) 1/2" Dia. Bolt Holes 10.3

A

BC

D F

E

49

Page 54: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

ABCA

B

C

EFD

D

EF

GH

G

H

UPS 43-100

UPS 50-60

UPS 43-44

50

Page 55: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Lochinvar’s Stainless Steel Buffer Tanks are designed to provide thermal storage volume and hydraulic separation of the boiler or heat pump and the building distribution system. A properly applied buffer tank will reduce on/off cycling (short cycling), which will lead to longer runtimes, higher efficiencies and longer equipment life. Squire buffer tanks can be used in geothermal, chilled water applications, and any system with low-mass boilers.

Hydronic buffer tanks are utilized to provide thermal

storage volume when the system demand is less than

the lowest firing rate of the boiler. This occurs most

often when there are “micro” zones in the distribution

system whose demand is below the minimum firing rate

of the boiler. Under these conditions the boiler fires

at its minimum rate, which is more energy than can

be absorbed by the distribution system, and shuts off

because of high return temperatures before the “micro”

zone’s call for heat is satisfied. The boiler system

continues to receive a call for heat and fires again. The

“micro” zone cannot absorb all the energy produced by

the boiler, and again the boiler shuts off because of high

return temperatures. With the volume provided by the

tank the additional energy not utilized by the “micro”

zone can be stored in the buffer tank and used when

there are additional heating demands.

Lochinvar’s Squire Buffer tanks also function as hydraulic

separators, effectively separating the flow in the boiler

loop from the flow in the distribution system. This is

beneficial when the flow rate in the distribution system

is different than the flow rate of the boiler system. It can

be very important when there is a variable speed pump

in the distribution system whose flow rate can be less

than that of the boiler pump.

gned to eparation ibution

ce on/off runtimes, quire water ers.

rmal

s than

ost

bution

ring rate

fires

can

uts off

“micro”

m

in. The

uced by

e of high

by the

icro”

when

hydraulic

boiler

is is

system

m. It can

d pump

e less

L o c h i n v a r .c o m

Stainless Steel Buffer Tanks

Stainless Steel Hydronic Buffer Tanks

Thermal Storage

Hydraulic Separation

Capacities from30 - 120 Gallons

5 Year Limited Warranty

51

Page 56: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Stainless Steel Hydronic Buffer Tank Dimensions and Specifications

Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000www.Lochinvar.com

FG-10M-10/11–Printed in U.S.A.SBT-02 (replaces SBT-01 9/10)

Model Gallon Supply/Return Shipping Number Capacity A B D E F G Connections Wt. (lbs.)SBT030 30 39-1/2” 20 28-3/4” 20-1/4” 11-3/4” 7-3/4” 1-1/2” NPT 70SBT050 50 47 24 33-3/4” 24-1/4” 14-3/4” 8-3/4” 1-1/2” NPT 120SBT080 80 69-1/2” 24 55-3/4” 35-1/4” 14-3/4” 8-3/4” 2” NPT 153SBT119 119 68-1/4” 28 54-3/4” 34-1/4” 15 9 2” NPT 198

SBT Models

All models standard with a 5 Year Limited Warranty Against Tank Failure.

Standard Features> R-13.4 insulation for minimal heat loss

> Textured, impact resistant polymer jacket

> Light-weight 316L stainless steel tank construction

> Bulbwell

> Drain and air vent connections

> 5 year tank warranty

52

Page 57: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

male Female male

53

Page 58: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Installation & Operation Manual

First Hour Rating - 180°F Boiler Loop Water(Universal Sizing - 45,000 - 295,000 Btu/hr)

Model SIT030 SIT040 SIT050

Circulator FlowGPM

5 8 12 16 20 5 8 12 16 20 5 8 12 16 20

Domestic Outlet 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140

45,000 108 83 108 83 122 97 122 97 135 110 135 110

60,000 136 103 136 103 150 118 150 118 164 131 164 131

75,000 165 123 165 123 179 138 179 138 194 151 194 151

95,000 171 128 191 142 202 150 217 165 217 165 217 165 233 179 233 179 233 179

115,000 171 128 191 142 223 165 240 177 217 165 252 189 252 189 252 189 233 179 268 204 273 207 273 207

140,000 191 142 223 165 240 177 267 196 252 189 267 200 282 211 286 208 268 204 292 221 307 232 322 242

165,000 240 177 267 196 267 200 282 211 286 213 292 221 307 232 334 251

195,000 334 251

225,000

260,000

295,000

MAX BTU INPUT 77008 89165 105532 114761 129676 92998 112972 123331 129574 132764 94115 114116 125111 134044 146207

Table 8C First Hour Rating - 180°F Boiler Loop Water (Universal Sizing)

8 Performance Data (continued)

Boi

ler

Hea

tin

gC

apac

ity

First Hour Rating - 180°F Boiler Loop Water(Universal Sizing - 45,000 - 295,000 Btu/hr)

Model SIT065 SIT080 SIT119

Circulator FlowGPM

5 8 12 16 20 5 8 12 16 20 5 8 12 16 20

Domestic Outlet 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140

45,000 153 128 153 128 163 138 163 138 197 172 197 172

60,000 183 149 183 149 193 159 193 159 226 193 226 193

75,000 213 170 213 170 222 180 222 180 255 213 255 213

95,000 252 197 252 197 252 197 261 207 261 207 261 207 294 241 294 241 294 241

115,000 291 226 291 226 291 226 291 226 300 235 300 235 300 235 300 235 333 268 333 268 333 268 333 268

140,000 305 235 319 245 338 259 338 259 338 259 304 238 347 268 347 268 347 268 347 268 384 302 382 302 382 302 382 302 382 302

165,000 305 235 319 245 356 271 386 293 388 294 304 238 349 270 374 288 395 302 395 302 387 306 429 337 429 337 429 337 429 337

195,000 319 245 356 271 386 293 388 294 349 270 374 288 409 312 424 323 483 375 485 376 485 376 485 376

225,000 356 271 386 293 388 294 374 288 409 312 424 323 501 388 548 421 541 416

260,000 388 294 424 323 573 438 596 454

295,000 596 454

MAX BTU INPUT 118488 129139 146864 163768 167924 115860 139106 154002 171229 181544 141419 190161 204795 237649 253504

Boi

ler

Hea

tin

gC

apac

ity

54

Page 59: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Installation & Operation Manual

8 Performance Data (continued)

How to Properly Size Your Indirect Water HeaterUse the First Hour Rating (FHR) to properly size your Indirect Water Heater. The First Hour Rating is the amount of hot waterin gallons the heater can supply per hour (starting with a tank full of hot water), depending on tank capacity, source of heat,and the size of the burner.

Estimate your peak hour demand as follows:

• Determine what time of day (morning, noon, evening) you use the most hot water in your home. Keep in mind the number of people living in your home.

• Use the worksheet below to estimate your maximum usage of hot water during this one hour of the day -- this is your peak hour demand. Note: The worksheet does not estimate total daily hot water usage.

The worksheet example shows a total peak hour demand of 165 gallons; therefore, this household would need a water heaterwith a First Hour Rating of no less than 165 gallons.

Fixture Count Guide

To quickly estimate the minimum gallons of hot water required based on a family size number of baths and hot waterappliances the First Hour Rating of the Squire must be equal to or exceed the total first hour requirements.

Peak Hour Demand Worksheet

Description Fill in the Blank Example

40 Gallons for the first 2 people Gals. 40 Gals.

10 Gallons for each additional person Gals. 20 Gals.

20 Gallons for each bath after the first

(consecutive bath) Gals. 20 Gals.

10 Gallons if dishwasher is used Gals. 10 Gals.

20 Gallons if clothes washer is used Gals. 20 Gals.

TOTAL Gals. 110 Gals.

Heavy Usage Buffer

Use if family members take longer than average showers, etc.x 1.5 x 1.5

First Hour Rating Gals. 165 Gals.

Proceed to pages 21 – 23 of this manual to locate your Indirect Water Heater and Boiler in the sizing charts. Using the FirstHour Rating calculated in this worksheet, locate your Indirect Water Heater and Boiler along with your First Hour Rating. Thiswill also determine the flow needed between the Indirect Water Heater and Boiler.

55

Page 60: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

WH-055 WH-085 WH-110 WH-155 WH-199 WH- 285 WH-399

WATER

GALLON CAPACITY 2.5 2.5 3.5 3.5 5.0 5.0 6.5

HEATING SURFACE (SQ. FT.) 5.92 8.33 10.00 14.07 15.66 21.60 36.58

WATER CONNECTIONS 1" 1" 1" 1" 1-1/4" 1-1/4" 1-1/2"

20°F T WATER FLOW (GPM) 5 8 10 15 19 27 38

HEAD LOSS (FT. OF HD.) 0.27 0.94 1.53 3.50 1.13 2.42 1.42

35°F T WATER FLOW (GPM) 3 5 6 9 11 16 22

HEAD LOSS (FT. OF HD.) 0.10 0.37 0.55 1.45 0.38 0.85 0.48

MAX. WORKING PRESSURE (PSI) 80 80 80 80 80 80 80

# OF RELIEF VALVES 1 1 1 1 1 1 1

RELIEF VALVE SIZE 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"

RELIEF VALVE RATING (MBH) 535 535 535 535 535 535 535RELIEF VALVE PRESSURE RATING (PSI) 30 30 30 30 30 30 30

GAS

INLET CONNECTION 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4"

MAX. INLET PRESSURE, NAT 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c.

MIN. INLET PRESSURE, NAT 4.0" w.c. 4.0" w.c. 4.0" w.c. 4.0" w.c. 4.0" w.c. 4.0" w.c. 4.0" w.c.

MAX. INLET PRESSURE, LP 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c. 14.0" w.c.

MIN. INLET PRESSURE, LP 8.0" w.c. 8.0" w.c. 8.0" w.c. 8.0" w.c. 8.0" w.c. 8.0" w.c. 8.0" w.c.

BTU/HR INPUT 55,000 85,000 110,000 155,000 199,999 285,000 399,999

BTU/HR OUTPUT (HIGH FIRE) 52,250 80,750 104,500 147,250 189,999 270,750 379,999BTU/HR OUTPUT (LOW FIRE) 10,450 16,150 20,900 29,450 38,000 54,150 76,000

ELECTRICAL

VOLTAGE/HEATER 120 120 120 120 120 120 120

VOLTAGE/CONTROL 24 24 24 24 24 24 24

TOTAL AMPS 0.5 0.5 0.5 0.5 1.5 1.5 2.0# OF ELECTRICAL CONNECTIONS 1 1 1 1 1 1 1

DIMENSIONS

HEIGHT 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 33-1/4" 35-1/2"

WIDTH 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 18-1/2" 25"DEPTH 16" 16" 19" 19" 19" 19" 21-3/4"

SERVICE CLEARANCES

FRONT 24" 24" 24" 24" 24" 24" 24"

BOTTOM 24" 24" 24" 24" 24" 24" 24"

RIGHT SIDE 0" 0" 0" 0" 0" 0" 0"

LEFT SIDE 24" 24" 24" 24" 24" 24" 24"TOP 6" 6" 6" 6" 6" 6" 6"

DIRECT VENTING

SIZE 2" 2" 3" 3" 3" 3" 4"

VENT CATEGORY IV

VENT MATERIAL PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS PVC/CPVC/SS

www.Lochinvar.com

56

Page 61: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

www.SunReports.com 20070726

DEVICE FEATURES Compact Size (5.5”x 4”x 1.4”) Easy to Install – Plug and Play One Unit Monitors Solar Thermal and PV*

Modular Sensor Design “ZERO Config” Setup (patent pending) Universal Interface for Solar Thermal Universal Interface for PV*

Solar Thermal Sensors: o 3 Temperature Inputs (Tank Input,

Tank Output, Top of Tank) o 2 A/C Load Inputs (pump status, re-

heat coil status) o 1 Grundfos Flow Sensor Adapter

Cable o Pressure Switch Input PV Connection via standard Ethernet Cable Standard Ethernet connection to existing router LEDs to indicate local status Interfaces to SunReports Web 2.0 portal

WEB PORTAL FEATURES Displays current and past performance Calculates BTU usage Integrates data into one easy to read chart Customer and Installer Portals Configurable Alerts**

Summary of System Performance**

DESCRIPTION The Apollo1 Energy Monitoring Device provides “performance based” residential energy monitoring for both Solar Electric (PV) and Solar Thermal (HW). The ultra-low-cost solution brings the benefits of web-based monitoring within reach for all customers. With the ‘ZERO-Configuration’ setup, installation is simple and requires no on-site configuration or networking experience. Simply plug in the sensors and connect to an existing router and the unit self-configures to begin sending data immediately. The Apollo1 automatically interfaces to the SunReports Web2.0 portal via standard Ethernet to present real-time and historical data in an easy to understand format. The SunReports design philosophy is to “make energy easy”, easy to install, easy to use, and easy to understand.

Installer and Customer web portals are accessible anywhere there is a web-browser and an Internet connection. No application software required. Access SunReports monitoring from home, office, or around the world via any web-enabled desktop computer, laptop, netbook, or smart phone. The same unit is capable of monitoring solar PV, solar Hot Water, and solar Pool Heating systems. Installers can use the Installer Portal to monitor all their installations from one remote location.

DATA SHEET

Apollo1 Energy Monitor

57

Page 62: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

www.SunReports.com 20070726

SunReports, Inc.415 891 9227

[email protected]

INCLUDED 1 Apollo1 Device 1 Ethernet Cable 1 Inverter Cable 2 A/C Load Cables (CT1 & CT2) 1 Grundfos Flow Sensor Adapter Cable 1 Triple Temperature Sensor Cable 1 Pressure Switch Cable*

1 A/C Adapter (universal input, US plug) Quick Start Guide

* Pressure Switch Sold Separately

OPTIONAL ACCESSORIES Communication Package including Power Line Carrier (PLC) network bridge Pressure Switch Grundfos VFS Flow Sensor

SPECIFICATIONSInput Power: - 5VDC, 1A AC Adapter Input: - 100-240VAC 50/60Hz AC Adapter Plug - US 2-prong Physical Dimensions: - 5.5 x 4 x 1.4in - (139.7 x 101.6 x 35.6mm) Weight - 1.8lbs (0.82kg) with cables Housing Material: - Flame retardant ABS plastic Housing Rating: - UL 94-5VA Regulatory: - FCC-15 Class A Operating Temperature - 0-40 C (32-104 F)

Cable Lengths: - 14’ Ethernet Cable - 14’ Inverter Cable - 5’ A/C Load Cables (CT1 & CT2) - 9’ Triple Temperature Sensor Cable**

- 4’ Pressure Switch Cable - 6’ A/C Adapter ** 3’ common plus 6’ for each sensor

Installer Portal – Map View

Target Performance

Apollo1 Energy Monitor

58

Page 63: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

1 20100727 www.SunReports.com

Apollo2 Energy Monitor

DEVICE FEATURES 6 Temperature Sensors 2 Data Ports

o Flow Meter(s) o CT Sensor(s)

1 Pressure Sensor Input Ethernet to Existing Internet Connection Static IP or DHCP Network option Connects Directly to Inverter Monitors Thermal AND PV

WEB PORTAL FEATURES Separate Secure Login for Installer and User Installer Portal with Integrated Google Maps, Custom Alert Configuration, and Comparative Performance Charts 5 Year Service Model Access Data from Any Web Browser, Anywhere in the World Computer and Mobile Phone, iPhone Compatible View Predicted vs. Actual Performance for kWh and BTU/hr Compare Heat Generated vs. Hot Water ConsumedNo Software to Install

DESCRIPTION The Apollo2 Energy Monitoring System has been engineered for commercial applications and provides “performance based” energy monitoring for both Solar Electric (PV) and Solar Thermal (HW) systems. The affordable Apollo2 solution brings the benefits of web-based monitoring within reach for all customers. With the ‘ZERO Config’ setup, installation is simple and requires no on-site configuration or networking experience. Simply plug in the sensors and connect to an existing router and the unit self-configures to begin sending data immediately. The Apollo2 automatically interfaces to the SunReports Web2.0 portal via standard Ethernet to present real-time and historical data in an easy to understand format. The SunReports design philosophy is to “make energy easy”; easy to install, easy to use, and easy to understand.

Installer and Customer web portals are accessible anywhere there is a web-browser and an Internet connection. No application software required. Access SunReports monitoring from the home, office, or around the world via any web-enabled desktop computer, laptop, netbook, or smart phone. The same unit is capable of monitoring solar PV, solar Hot Water, and solar Pool Heating systems. Installers can use the Installer Portal to monitor all their installations from one remote location.

Robust and affordable remote monitoring system for Solar Thermal and Solar PV installations

59

Page 64: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

2 20100727 www.SunReports.com

Product Feature Comparison

Feature Apollo1

(Residential) Apollo2

(Commercial) Modular Sensors X X Thermal Monitoring X X PV Monitoring X X Internet Connectivity X X Pump On/Off Detect (AC Detect) X X DHCP Network Support X X Pressure Switch Compatible X X Local LED Indicators X X Wall Mount X X Flow Meter Compatible One Two 3-Loop Thermal Monitoring X Double Thermal Loop Monitoring X 6 Temperature Sensors X Static IP Network Support X

On-Line ReportingSecure Login X X Installer Portal X X User Portal X X Historical and Current Data X X Configurable Alerts* X X Interactive Google Maps* X X Predicted vs. Actual Charts* X X Energy Equivalence Display X X Double BTU Calculation* X Contribution to Total Energy Chart* X Thermal Loop Comparison Chart* X * Installer Portal Only

CONTACTSunReports, Inc.

[email protected]

Solar Production vs. Auxiliary Heating

Apollo2 Energy Monitor

INCLUDED 1 Apollo2 Device 1 Ethernet Cable 1 Inverter Cable 2 A/C Load (CT1 & CT2) 2 Grundfos® VFS Series Flow Sensor Cables 1 Six-Sensor Temperature Cable 1 Pressure Switch Cable 1 A/C Adapter (universal input, US plug) Quick Start Guide(s)

OPTIONAL ACCESSORIES Communication Package including Power Line Carrier (PLC) network bridge Pressure Switch Outdoor Mounting Kit

SPECIFICATIONSInput Power: - 5VDC, 1A AC Adapter: - 100-240VAC 50/60Hz - UL/CE/CUL/C-Tick/TUV - US 2-prong (others available) Physical Dimensions: - 5.5 x 4 x 1.4in - (139.7 x 101.6 x 35.6mm) Weight - 2.1lbs (0.95kg) with cables Housing Material: - Flame retardant ABS plastic Housing Rating: - UL 94-5VA Regulatory: - FCC-15 Class B - CE Mark - C-TickOperating Temperature - 0-50 C (32-122 F)

Cable Lengths: - 14’ Ethernet Cable - 14’ Inverter Cable - 5’ A/C Load Cables (CT1 & CT2) - 13’ Temperature Sensor Cable - 4’ Pressure Switch Cable - 6’ A/C Adapter

60

Page 65: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

FLO

W-G

PM

02

46

810

1214

1618

2022

2426

2830

3234

3638

4042

4446

4850

5254

TOTAL HEAD-FEET

024681012141618202224262830323436

FLO

W-M

3/H

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

8.0

8.5

9.0

9.5

10.0

10.5

11.0

11.5

12.0

TOTAL HEAD-METERS

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

8.0

8.5

9.0

9.5

10.0

10.5

11.0

003B

005

006

006B

007

008

009

0010

0011

0012

0013

0014

00 C

IRC

ULA

TOR

S

9/09

/09

61

Page 66: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

iSeries-R

BC

A

BC

ASupplySensor

N P ZC H X1 ZRX2

ZONE1 ZONE2 ZONE3

ZONE1 ZONE2 ZONE3

FUSE 1 AMP

24 VACPOWER

THREE ZONE SWITCHING RELAYWITH OPTIONAL PRIORITY

SR 503

24 Volt

Transform

er

H N

PowerInput

C R

24 VACPOWER INPUT

SENSORCOMMON

BOILER SUPPLY OUTDOOR

POWERGREEN

SENSORERROR

RED

BACK OF iVALVE-R MIXING VALVE ACTUATOR

OutdoorSensor

DHWCirc.

ADHW Aquastat

Thermostats

T

T

iValve, 3-Way Mixing Working with SR502/503 Switching Relay with DHW Priority

24 V

olt

Tran

sfor

mer

C R

24 VACPOWER INPUT

SENSORCOMMON

BOILER SUPPLY OUTDOOR

POWERGREEN

SENSORERROR

RED

BACK OF iVALVE-R MIXING VALVE ACTUATOR

MM

H

N

THREE ZONE ZONE VALVE CONTROL

ZVC 403

1 2 3 4ZONE 1

1 2 3 4ZONE 2

1 2 3 4ZONE 3E ND

SWITCH

ZONE 1T T

ZONE 2T T

ZONE 3T T

FUSE(5 AMP MAX)

N/O N/CCOM

iValve, 4-Way Mixing Working with Zone Valve Control

iSeries-R

Fact

ory

Inst

alle

dTr

ansf

orm

er

POW

ER IN

ThermostatsT

T

Mot

or

End

Sw

itch

Mot

or

End

Sw

itch

PowerInput

OutdoorSensor

BoilerSensor

SupplySensor

BoilerSensor

FOR ADDITIONAL WIRING DIAGRAMS, PLEASE SEE www.taco-hvac.com/wiringwizard

62

Page 67: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

63

Page 68: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

© 2005 D 710 - 05/05

D 71005/05

- Data Brochure3-Way Mixing Valves 710 - 714

The 3-Way Brass Mixing Valves 710, 711, 712, 713, and 714 are used to mix supply water from a heat source with water returning from a system. They are designed for use in either closed loop or open loop hydronic systems. All valves have standard female NPT threads. The valve provides a maximum leak through rate of 1% to allow for water expansion during temperature changes. The valve position can be manually set using the handle. An Actuating Motor 741 can be used to automatically operate the valve.

Sequence of Operation

Installation

Check the contents of the package. If any of the items listed below are missing or damaged, please refer to the Limited Warranty and Product Return Procedure on the back of this brochure and contact your wholesaler or local tekmar representative.

Types 710 - 714 include • One Mixing Valve & One Data Brochure D 710

When the flap is in the fully closed position, 100% of the heating system return water is supplied to the system. When the valve flap is in the fully open position, 100% of the boiler supply water enters the heating system. Mixing of the water takes place when the valve flap is in an intermediate position.

Replacement Parts

The Mixing Valve Handle Kit M3047 contains a replacement manual valve handle, a brass screw, a “C” clip, and a position indicator plate.

5 7 9 10

310

brass screw

handle

“C” clip

indicator plate

• Factory postion• No changes required

• Rotate handle 1/4 turn• Flip face plate over

• Rotate handle 1/4 turn• Rotate handle 1/2 turn• Flip face plate over

supply

return

fromboiler supply

return

fromboiler

supply

return

fromboilersupply

return

fromboiler

64

Page 69: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fax. (250) 545-0650Web Site: www.tekmarcontrols.com

Product design, software and literature are Copyright © 2005 by:tekmar Control Systems Ltd. and tekmar Control Systems, Inc.

All specifications are subject to change without notice.Printed in Canada. D 710 - 05/05.

Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowl-edges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same.

The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Prod-uct is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installa-tion if installed within twenty-four (24) months from the production date.

The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and/or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict prod-uct liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract.

The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers.

Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are

the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.

The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and/or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar’s instructions.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTU-ALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABIL-ITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEG-ISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRAC-TUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.

Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact informa-tion regarding the appropriate Representative.

Limited Warranty and Product Return Procedure

3-Way Mixing Valves 710 - 714 Brass

Technical Data

Type Pipe Size CV Value Dimension H Dimension W Packaged Weight710 3/4” 7 1-1/2” (38 mm) 3” (76 mm) 1.9 lbs (860 g)711 1” 14 1-1/2” (38 mm) 3” (76 mm) 1.6 lbs (730 g)712 1-1/4” 21 1-5/8” (41 mm) 3-1/4” (82 mm) 1.8 lbs (800 g)713 1-1/2” 32 2-3/16” (56 mm) 4-3/8” (111 mm) 6.7 lbs (3020 g)714 2” 51 2-5/16” (60 mm) 4-5/8” (119 mm) 5.6 lbs (2520 g)

Literature — D 710Maximum Operating Pressure — 146 psi (10 bar)Operating Temperature Range — -20 to 248°F (-28 to 120°C)Valve Body and Vane — CW 617N - EN 12165 BrassShaft Seal — Viton “O” ringMain Seal — EPDM Perioxide “O” ring

Acceptable Fluid Media — Chilled and hot water with antifreeze and anticorrosive compounds (max 60%), glycol, ethyl alcohol glycol, propylene dichloride alcohol, mono ethyl alcohol, ethyl methyl alcohol, glycerine.

Not for use with media based on mineral oil components or chlorinated pool water.

00

0.2

0.4

0.6

0.8

1

0

0.5

1

1.5

0

1

2

3

2 4 6 8 10 12 14 16 18 20

710 711

Valve Performance 710, 711

psi

ft o

f h

ead

m o

f h

ead

US Gal/min

0 1m3/h

NormalOperatingRange

2 3 4

00

0.5

1

1.5

10 20 30 40 50 60 70 80

713712 714

Valve Performance 712, 713, 714

US Gal/min

psi

0

0 3 6 9 12 15 18

0.2

0.4

0.6

0.8

1

m o

f h

ead

0

1

2

3

ft o

f h

ead

m3/h

NormalOperatingRange

W

H

65

Page 70: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

D 710A 07/07Replacement O-Rings for 3/4 to 1-1/4” Brass Valves (M3056)

- Data Brochure Addendum

D 710A - 07/07

Screw

Blue Handle

C-Clip

Indicator Plate

Retainer Clip

White Plastic Washer

Small O-Ring

O-Ring Housing

Large O-Ring

Medium O-Ring(has white marking)

Valve Flap

Valve Body

Repair procedure:

1. Remove screw attaching blue handle. If an actuator motor is installed, remove hand wheel and screw.

2. Pull blue handle or actuator motor off of valve assembly.

3. Insert flat blade screwdriver into either rear slot of c-clip. Twist screwdriver to pry off clip.

4. Mark the indicator plate position for later reference. Remove metal indicator plate.

5. Insert small flat blade screwdriver into notch in valve body and pry out metal retainer clip.

6. Remove valve flap assembly by pulling on shaft.

7. Remove white plastic washer, if present.

8. Remove metal o-ring housing from valve flap.

9. Remove medium o-ring and clean surface on valve flap using steel wool. Install medium o-ring (with white mark) on valve flap.

10. Remove small and large o-rings and clean surface on o-ring housing using steel wool. Install small and large o-rings on o-ring housing.

11. Re-install o-ring housing onto valve flap.

12. Re-install valve flap assembly into valve body.

13. Re-install metal retainer clip into valve body. Make sure it is snapped all the way around.

14. Use your finger to push the small o-ring down between the valve flap shaft and o-ring housing.

15. Re-install white plastic washer over shaft, if present.

16. Re-install indicator plate.

17. Re-install c-clip onto valve shaft.

18. Re-install blue handle and screw or actuator motor, screw and handwheel.

19. Rotate handle through its full motion both ways. It should be smooth and stop at the ends of the range indicated on the plate.

This seal replacement kit is for tekmar Brass Valve models 710, 711, 712, 720, 721 and 722. The kit includes a small o-ring, a medium o-ring indicated with a white paint mark, and a large o-ring. All o-rings are lubricated with silicone grease.

66

Page 71: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

D 710B 07/07Replacement O-Rings for 1-1/2 to 2” Brass Valves (M3057)

- Data Brochure Addendum

D 710B - 07/07

Screw

Blue Handle

C-Clip

Indicator Plate

Small O-Ring

Valve Body

Medium O-Ring(has white marking)

Valve Flap

Large O-Ring

Bottom Cover

Repair procedure:

1. Remove screw attaching blue handle. If an actuator motor is installed, remove hand wheel and screw.

2. Pull blue handle or actuator motor off of valve assembly.

3. Insert flat blade screwdriver into either rear slot of c-clip. Twist screwdriver to pry off clip.

4. Mark the indicator plate position for later reference. Remove metal indicator plate.

5. Turn valve assembly over and use special tool to unscrew bottom cover.

6. Push valve flap assembly out through bottom of valve body.

7. Remove small o-ring from top of valve body.

8. Clean top of valve body using steel wool.

9. Remove medium o-ring from shaft of valve flap.

10. Clean the shaft of valve flap using steel wool and install new medium o-ring (with white mark) on shaft of valve flap.

11. Re-install valve flap assembly into valve body.

12. Remove the large o-ring from the bottom cover.

13. Clean the bottom cover using steel wool and replace the large o-ring.

14. Re-install bottom cover using special tool.

15. Install new small o-ring onto shaft of valve flap. Use your finger to push the o-ring down between the valve body and shaft.

16. Re-install indicator plate.

17. Re-install c-clip onto valve shaft.

18. Re-install blue handle and screw or actuator motor, screw and handwheel.

19. Rotate handle through its full motion both ways. It should be smooth and stop at the ends of the range indicated on the plate.

This seal replacement kit is for tekmar Brass Valve models 713, 714, 723 and 724. The kit includes a small o-ring, a medium o-ring indicated with a white paint mark, and a large o-ring. All o-rings are lubricated with silicone grease.

Bottom Cover Removal Tool AssemblyTo remove the bottom cover of the valve, a special tool can be assembled using the following:

One 1/2” NC x 2” long bolt with 3/4” hex head

Two 1/2” NC nuts

Thread both nuts onto the bolt. Then thread the first nut backwards to lock against the second nut.

67

Page 72: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

TURBOMAX INDIRECT WATER HEATERS

TURBOMAX® 109Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

400 000 117 807 531 363 687 483 346

500 000 146 979 651 450 859 603 436

600 000 176 1151 772 536 1031 724 516

700 000 205 1323 893 1202 845

800 000 234 1494 1013 1374 965

900 000 264 1666 1546

TURBOMAX® 65Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

200 000 59 416 270 183 344 241 173

250 000 73 501 331 227 429 302 216

300 000 88 587 391 270 515 362 260

350 000 103 673 451 601 422

400 000 117 759 512 687 483

450 000 132 845 572 773 543

500 000 146 931 859

TURBOMAX® 45Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

200 000 59 392 261 180 344 241 173

250 000 73 477 321 223 429 302 216

300 000 88 563 381 266 515 362 260

350 000 103 649 442 601 422

400 000 117 735 502 687 483

450 000 132 821 562 773 543

500 000 146 907 859

TURBOMAX® 24Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

50 000 15 112 71 47 88 60 43

100 000 29 198 131 90 172 121 87

150 000 44 284 192 134 258 181 130

200 000 59 370 252 177 344 241 173

250 000 73 455 312 220 429 302 216

300 000 88 542 373 515 362

350 000 103 628 433 601 422

400 000 117 714 687

TURBOMAX® 44Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

50 000 15 134 80 50 86 60 43

100 000 29 220 140 93 172 121 87

150 000 44 306 200 137 258 181 130

200 000 59 392 261 180 344 241 173

250 000 73 477 321 223 429 302 216

300 000 88 563 381 515 362

350 000 103 649 442 601 422

400 000 117 735 687

TURBOMAX® 23Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

50 000 15 112 71 47 86 60 43

100 000 29 198 131 90 172 121 87

150 000 44 284 192 134 258 181 130

200 000 59 370 252 344 241

250 000 73 456 312 429 302

300 000 88 542 515

TURBOMAX® 33Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

50 000 15 126 76 49 86 60 43

100 000 29 211 137 92 172 121 87

150 000 44 297 197 135 258 181 130

200 000 59 383 257 179 344 241

250 000 73 469 318 222 429 302

300 000 88 555 378 515

SpecificationsTank Heat transfer Utility Boiler Shipping

Model volume area (sq.ft.) connection connection Hgt. Diam. weight

TURBOMAX 109 119 US gal. 58.9 ft2 2’’ Sweat M 2’’ NPTM 74’’ 29’’ 555 lbs

TURBOMAX 65 72 US gal. 32.7 ft2 1 1/2’’ Sweat M 1 1/2’’ NPTM 67’’ 24’’ 250 lbs

TURBOMAX 45 48 US gal. 32.7 ft2 1 1/2’’ Sweat M 1 1/4’’ NPTM 55’’ 22’’ 235 lbs

TURBOMAX 44 48 US gal. 26.2 ft2 1 1/2’’ Sweat M 1 1/4’’ NPTM 55’’ 22’’ 210 lbs

TURBOMAX 34 36 US gal. 26.2 ft2 1 1/2’’ Sweat M 1 1/4’’ NPTM 65’’ 18’’ 195 lbs

TURBOMAX 33 36 US gal. 19.6 ft2 1 1/4’’ Sweat M 1 1/4’’ NPTM 65’’ 18’’ 170 lbs

TURBOMAX 24 26 US gal. 26.2 ft2 1 1/2’’ Sweat M 1 1/4’’ NPTM 49’’ 18’’ 175 lbs

TURBOMAX 23 26 US gal. 19.6 ft2 1 1/4’’ Sweat M 1 1/4’ NPTM 49’’ 18’’ 150 lbs

Standard Equipment

† Based on ASHRAE (D.O.E.) test method performed by CRIQ.Domestic cold water at 40°F and boiler water at 180°F.

Pressure reliefvalve set at 30 psi

Domestic hot wateroutlet

Temperature/-pressure gauge

Boiler supply

Aquastatprewired for

120 or 24V

Domestic cold water

inlet

Boilerreturn

Drainvalve

Adjustable feetfor levelling

Copper heatexchanger insidehigh quality carbosteel tank

Fiberglassinsulation

Steel jacketpainted withdurable epoxy

TURBOMAX® 34Domestic hot water produced per hour in U.S. gallons†

Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110°F 140°F 180°F

50 000 15 126 76 49 88 60 43

100 000 29 211 137 92 172 121 87

150 000 44 297 197 135 258 181 130

200 000 59 383 257 179 344 241 173

250 000 73 469 318 222 429 302 216

300 000 88 555 378 515 362

350 000 103 641 438 601 422

400 000 117 727 687

®

Copyright © 2007 Thermo 2000 Inc. All rights reserved. TURBOMAX is a trademarkof Thermo 2000 Inc. Thermo 2000 Inc. reserves the right to modify at any time andwithout notice colors, components, materials, specifications or models described inor shown in this brochure.

ASME Models SpecificationsTank Heat transfer Utility Boiler Shipping

Model volume area (sq.ft.) connection connection Hgt. Diam. weight

TURBOMAX 109A 110 US gal. 58.9 ft2 21/2’’ Sweat M 2’’ NPTM 74’’ 29’’ 755 lbs

TURBOMAX 65A 70 US gal. 32.7 ft2 2’’ Sweat M 11/2’’ NPTM 67’’ 24’’ 340 lbs

Technical InformationStandby loss <1/2°F per hour

Heat Transfer Efficiency = 99%

Output Temperature up to 200°F

Tube Max. Allowed ASME = 150 PSI at 250°FWorking Pressure

Shell Max. Allowed ASME = 150 PSI at 250°FWorking Pressure

68

Page 73: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

TechDataPRODUCT SPECIFICATION SHEET

TD-PRVPB 0507

VIEGA301 N. Main, Floor 9Wichita, KS 67202

Phone: 1-877-VIEGA-NAFax: 1-800-976-9817

[email protected]

ViegaPEX BarrierQuality AssuranceViegaPEX Barrier tubing is manufactured and tested tothe requirements of ASTM F876 and F877. The degreeof cross-linking of finished tubing is determined bymethod ASTM D2765.

Certifications- tested for health effects to ANSI/NSF 61and performance to ANSI/NSF standard 14.

PRESSURE DROP TABLEExpressed per/ft.

SIZE5/16” 3/8” 1/2” 5/8” 3/4” 1” 1-1/4” 1-1/2”

GPM PSI Head PSI Head PSI Head PSI Head PSI Head PSI Head PSI Head PSI HeadLoss Loss Loss Loss Loss Loss Loss Loss

.1 .002 .005 .001 .001

.2 .009 .021 .004 .008 .001 .002

.3 .018 .042 .008 .017 .002 .004 .001 .002

.4 .031 .072 .013 .030 .003 .007 .001 .002

.5 .047 .109 .020 .045 .004 .010 .002 .004

.6 .066 .152 .027 .063 .006 .014 .003 .006 .001 .003

.7 .088 .203 .036 .084 .008 .019 .003 .008 .002 .004

.8 .047 .108 .011 .024 .004 .010 .002 .005

.9 .058 .134 .013 .030 .005 .012 .002 .0061 .070 .1626 .016 .037 .007 .015 .003 .007 .001 .0021.5 .034 .078 .014 .032 .006 .015 .002 .0042 .058 .133 .024 .055 .011 .025 .003 .0073 .050 .116 .023 .052 .007 .0154 .085 .197 .039 .089 .011 .0266 .181 .417 .082 .189 .024 .0568 .140 .322 .041 .09510 .211 .487 .062 .143 .023 .05412 .296 .683 .087 .201 .032 .07514 .042 .09816 .053 .123 .022 .05218 .065 .151 .027 .06320 .078 .182 .033 .07722 .093 .217 .039 .09124 .108 .252 .045 .10526 .052 .12128 .060 .14030 .067 .15632 .075 .175

SDR-9 PEX TubingASTM F876/F877/CTS-OD SDR-9

TUBING WALL NOM. WEIGHT VOLUME (GAL)/SIZE O.D. THICKNESS I.D. PER FT 100 ft5/16” .430±.003 .064+.010 0.292 .0340 0.343/8" .500±.003 .070+.010 0.350 .0413 0.501/2" .625±.004 .070+.010 0.475 .0535 0.925/8" .750±.004 .083+.010 0.574 .0752 1.343/4" .875±.004 .097+.010 0.671 .1023 1.821" 1.125±.005 .125+.010 0.863 .1689 3.04

1-1/4" 1.375±.005 .153+.015 1.053 .2523 4.521-1/2" 1.625±.006 .181+.019 1.243 .3536 6.30

NOTE: Dimensions are in English units. Tolerances shown are ASTMrequirements. ViegaPEX Barrier is manufactured to within thesespecifications.

ViegaPEX Barrier tubing is available in both straight lengths and coils.

When the tube spacing is less than the minimumrecommended bending dimension, the loop endsshould be swept out to at least the dimensions shown.

Otherwise, if tube spacing is equal or greater than “X”,a standard loop may be used.

When tube spacing is lessthan minimum bend dimension.

Dimension XTubing Size With the Coil

5/16” 7”

3/8" 8”1/2" 10”5/8" 12”3/4" 14”1" 18”

1-1/4” 22”1-1/2” 26”

ViegaPEX Barrier OxygenPermeation:All sizes have less than0.1 grams/m3/day

Note: ViegaPEX Barriertubing meets DIN 4726requirement for oxygentight pipes.

69

Page 74: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Viega 1-800-976-9819 www.viega.com

Pressure Drop

70

Page 75: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

IM-PR 0512 (Design Manual)

0.1

1.0

10.0

100.0

0.01

0.10

1.00

10.00

Flow

Rate

(GPM

)

Pressure Drop, 40% Propylene Glycol (FT OF HEAD PER FT OF TUBING)

0.5

5.0

50.0

0.02

0.03

0.040.050.06

0.08

0.20

0.30

0.400.500.60

0.80

3.00

2.00

4.005.006.00

8.00

ViegaPEX Barrier Tubing

0.1

1.0

10.0

100.0

0 0 0 1 10

Flow

Rat

e(G

PM)

Pressure Drop, 40% Propylene Glycol (FT OF HEAD PER FT OF TUBING)

0.5

5.0

50.0

32 4 5 6 80.40.50.60.8

0.3

0.2

0.2

0.10.08

0.050.040.03

0.06

0.002

0.0030.004

0.006

0.01

0.001

0.008

Type M Copper Tubing

200.0

Table 1-17. Forty percent propylene glycol pressure drop table for ViegaPEX Barrier tubing.

Table 1-18. Forty percent propylene glycol pressure drop table for Type M copper tubing.

1½"1¼"

¾"

⅝"

½"

⅜"

5 ⁄16"

1½"3½" 2½"1¼"

¾"

½"

⅜"

Viega Pex & Copper M 40% Glycol Pressure Drop

71

Page 76: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

VIEGA NA 877-VIEGA-NA IM-SNO-1006

SYSTEM DESIGN - CHAPTER 3

3.3 Calculating the Tube

Spacing:

3.4 Calculating the Fluid

Supply Temperature:

Decreasing the tube spacing will allowthe snow melting system to operateat lower fluid temperatures whilemeeting the heat outputrequirements. Use table 3.3 to theright to calculate the proper tubespacing.

Procedure:1. Find the tube size in the first

column.

2. Follow to the right and read therecommended tube spacing underthe column representing the heatload.

Example:Tube size: 5/8”Snow melting load: 200 Btu/h*ftRecommended tube spacing: 9”

Table 3.3Notes:• Space tubing 1 inch closer for

each inch of concrete cover over 2 inches.• Space tubing 2 inches closer for each

additional inch of pavers > 2-3/8” pavers.• Space tubing 1 inch closer for asphalt applications.

Use table 3.4 to calculate the fluid(antifreeze solution) supplytemperature.

Procedure:1. Find the snow melting load in the

first column.

2. Follow to the right and read therecommended fluid supplytemperature under the columnrepresenting the selected tubespacing.

Example:Snow melting load: 200 Btu/h*ftTube spacing: 9 inchesFluid supply temperature: 131°F

Note:Fluid supply temperature of 130°F istypical for snow melting applications.

Table 3.4* Based on a 30 F° temperature drop

Recommended Tube

Spacing in Concrete

Snow Melting Load

(Btu/h*ft2)

Tube

Size

Max. Circuit

Length100 150 200 250 300

1/2" 150 ft 9" 9" 6" 6" 6"

5/8" 250 ft 9" 9" 9" 6" 6"

3/4" 400 ft 12" 12" 9" 9" 6"

Fluid Supply Temperature (°F)*

Snow Melting

Load

(Btu/h*ft2)

Tube Spacing (inches)

6 9 12

100 100 100 103

150 100 106 128

200 108 131 153

250 133 156

300 158

72

Page 77: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

IM-PR 0512 (Design Manual)

Application LocationOn-Center Spacing

(in., typical)Nominal Tubing Size

(in., typical)

In-Slab

On or Above Grade Living Areas

9" ½" or ⅝"*

Below Grade 9" – 12" ½" or ⅝"*

Bathrooms and High Output Areas

6" – 9" ⅜" or ½"

Gypsum-concrete(thin-slab)

6" – 9" ½"

Garages and Workshops, Interior Zones of Large

Commercial Buildings or Warehouses

12" ½", ⅝", or ¾"

Dry Mass

Above Sub-Floor Panels 7" – 10" 5∕16"

Below Sub-Floor (Residential Only)

8" ⅜" or ½"

Wall Panels 7" – 10" 5∕16"

Table 1-5. Typical spacing and nominal tubing size, by application. *Used more commonly in commercial applications.

Tubing ≤ 25 Btu/hr/ft2 >25 Btu/hr/ft25∕16" 250 200

⅜" 300 250

½" 400 350

⅝" 500 450

¾" 800 750

Table 1-6. Maximum recommended circuit lengths in feet, assuming a temperature drop of ≥ 20°F, 100% water, and air temperature of 68°F.

Viega Typical Tube Spacing & Maximums

73

Page 78: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

VIEGA • One Company... One Partner... Delivering System Solutions.301 N. Main, Floor 9 • Wichita, KS 67202 • Ph: 877-Viega-NA • Fax: 800-976-9817 • E-Mail: [email protected] • www.viega-na.com

Product InstructionsStainless Manifold Shut Off/Balancing/Flow Meters

PI-PR-15900 0507518858

1.18” 1.15”

6.63”

12.08”

3.56”

5.31”

11.22”

TOTAL WIDTH

Dimensions

Height 12.1”

Depth 3.6”

Manifold Total Width

2 outlets 10.2”

3 outlets 10.2”

4 outlets 12.2”

5 outlets 14.1”

6 outlets 16.1”

7 outlets 18.1”

8 outlets 20.0”

9 outlets 22.0”

10 outlets 24.0”

11 outlets 25.9”

12 outlets 27.9”

Technical Data1. 1-1/4” 304 Stainless Header Stock

2. Supply Manifold with Balancing valve/flow meter

3. Return Manifold with shut off valves (blue caps)

4. Factory installed air bleeders and purge valves

5. Mounting Brackets

6. Max. operating temperature: 180°FShort periods of 200°F

7. Max. operating pressure: 100 psi

Product Description

Stainless manifold is to be used in closed loop hydronic heating, cooling and snow melting systems. Thesepreassembled 1-1/4” diameter stainless supply and return manifolds come attached to two 6-5/8” spacingbrackets for compact remote mounting. This stainless manifold provides shut off and balancing valves with flowmeters for each circuit. Each flow meter/balancing valve allows graduated flow setting up to 2 gpm, maximum18 gpm per manifold. The air bleeder and purge valves are connected and factory tested. 1-1/4” Unionconnections, 1” NPT removable end caps. SVC Circuit connection fittings are sold separately.

The return header is fitted with shutoff valves which are suitable to receiveoptional 24V powerheads for controlover each circuit via thermostat.

Note: Use new style white cappowerheads with this mainfold(stock code 15 061).

*When extending the manifold, Viega requires using thread sealant pasteand Teflon tape on the 1” NPT manifold end connection.

74

Page 79: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

5608 0

12

v1.0

Vitocrossal 200 CM2 Technical Data

Technical Data

Specifications

Boiler Model CM2 186 246 311

Input MBH 663 878 1112

(kW) (194) (257) (326)

Minimum Input MBH 133 175 222

(kW) (39) (51) (65)

Output*1 MBH(kW)

623(183)

826(242)

1052(308)

Combustion and

Thermal efficiency*1 % 94.0 94.1 94.6

Overall dimension

Overall length(e) in. 73 73 73

(mm) (1852) (1852) (1852)

Overall width (c) in. 36b 36b 36b

(including insulation) (mm) (930) (930) (930)

Overall height (a) in. 66 66 66

(including control unit) (mm) (1676) (1676) (1676)

Concrete boiler base

Length in. 40 40 40

(mm) (1005) (1005) (1005)

Width in. 31 31 31

(mm) (800) (800) (800)

Thickness in. 4 4 4

(mm) (100) (100) (100)

Weight

Boiler body lb 503 536 564

(Kg) (228) (243) (256)

Complete with the burner, control lb 726 759 792

and thermal insulation (Kg) (329) (344) (359)

*1 Tested to ANSI Z21.13/CSA 4.9 standards with a return water temperature of 80° F (27° C) and supply water temperature of 180° F (82° C).

Note: For high altitude installations (5,000 to 10,000 ft.), the input will have an altitude de-ration of 15% for 5,000 ft. and 18% for 10,000 ft.

75

Page 80: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

5608 0

12

v1.0

Vitocrossal 200 CM2 Technical Data Specifications

Technical Data (continued)

Boiler Model CM2 186 246 311

Boiler Water Content USG 81 77 74

(L) (306) (292) (279)

Heat exchanger surface ft.2 73.2 90.4 114.1

water cooled (m2) (6.8) (8.4) (10.6)

Maximum Operating Temperature °F 190 190 190

(°C) (88) (88) (88)

Maximum Operating Pressure psig 75 75 75

(kpa) (517) (517) (517)

Boiler Connections

Boiler supply and return (BS), (BR) in. 2b 2b 2b(ANSI flanges) (mm) (65) (65) (65)

Safety Supply in. 1a 1a 1a

(mm) (32) (32) (32)

Boiler Drain in. 1 1 1

Condensate Drain in. c c c

Vent pipe

Internal Diameter in. 8 8 8

(mm) (201) (201) (201)

Flue Gas Values

temperature (at a return temperature of 86° F (30° C)

at rated input °F 136 132 130

(°C) (58) (55) (54)

at partial load °F 95 95 95

(°C) (35) (35) (35)

Temperature (at a return temperature of 140° F (60° C)

at rated input °F 167 167 167

(°C) (75) (75) (75)

Mass flow rate (of flue gas)

at rated input lbs/h 593 785 994

(kg/h) (269) (356) (451)

at partial load lbs/h 198 262 331

(kg/h) (90) (119) (150)

Pressure

at boiler flue outlet pa 70 70 70

at rated input “w.c. 0.28 0.28 0.28

** Vent Diameter can be reduced to 6" on some models under certain circumstances at limited

lengths. Refer to Viessmann venting instructions for specific application.

** ** **

76

Page 81: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Waterside Flow

Waterside Flow (primary circuit)

The Vitodens 200-W, WB2B is designed for closed loop, forced circulation hot water heating systems only.

Pressure drop (primary circuit) for Vitodens200-W, WB2B 19, 26, 35For sizing an on-site circulation system.Max. flow rate: 1400 L/h / 6.2 GPM

Pressure drop (primary circuit) for Vitodens200-W, WB2B 45, 60For sizing an on-site circulation system.Max. flow rate 3500 L/h / 15.4 USGPM

Pressure drop (primary circuit) for Vitodens200-W, WB2B 80, 105For sizing an on-site circulation system.Max. flow rate 8000 L/h / 35.2 USGPM

Use standard friction loss method for pipe sizing. Observe boiler maximum and minimum flow rate limitations. If system flow rate exceedsboiler maximum flow rate (as stated above), falls below the minimum flow rate or if system flow rate is unknown, Viessmann stronglyrecommends the installation of a low-loss header. An alternative method may be used, such as primary secondary piping using closelyspaced tees. A low-loss header offers additional benefits not provided by a pair of closely spaced tees. Viessmann therefore stronglyrecommends and prefers the use of a low-loss header over closely spaced tees. See page 13 for low-loss header information.

5369

295

v1.0

0 500 1000 15000

1

2

3

4

5

6

0

3.3

6.6

9.8

13.1

16.4

19.7

2000 l/h

7

8

23

26

Sup

ply

head

pres

sure

(wat

er)

0 2.2 4.4 6.6 8.8 GPM

H(ft.) H(m)

Fig. 11

H(ft.) H(m)20.1 6.1

16.7 5.1

13.4 4.1

10.0 3.1

6.7 2.0

3.4 1.0

0 0

00 500 1000 1500 2000 2500 3000 3500 l/h

2.2 4.4 6.6 8.8 11 13.2 15.4 GPM

Sup

ply

head

pres

sure

(wat

er)

Fig. 12

H(ft.) H(m)33.5 10.2

30.1 9.2

8.226.8

7.123.4

6.120.1

5.116.7

4.113.4

3.110.0

2.06.7

1.03.4

0000

1000 2000 3000 4000 5000 6000 7000 8000 l/h4.4 8.8 13.2 17.6 22.0 26.4 30.8 35.2 GPM

Sup

ply

head

pres

sure

(wat

er)

Fig. 13

77

Page 82: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

78

Page 83: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Box A

Box A

NBP4-WHN

NBP4-105 – Lochinvar KBN105/106NBP4-080 – Lochinvar KBN 080/081

NBP4-150 – Lochinvar KBN150/151NBP4-210– Lochinvar KBN210/211

Complete floor mount piping

Box C

Box C

Box B

Box B

Box B & Box C combined

NBP4-WHN – Lochinvar WHN 055-155

79

Page 84: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

80

Page 85: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

81

Page 86: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

WILO Stratos

* Compared to an uncontrolled circulator.

0

20

30

40

10

0

2

4

6

8

10

12

0 40 80 120 160 200

0 5 10 15 20 25 30 35 40 45 50

H [f

t]

H [m

]

Q [US gpm]

Q [m3/h]

Wilo-Stratos60 Hz

3x3-302x3-35

1.5x3-40

1.25x3-30

1.25x3-20

3x3-401.25x3-25

1.25x3-35

p-T control mode

Hs max

Hs min

T min T max T med Q min Q max Q

Hs

Hs var.p-v control mode

Q

H

Hs

½ Hs

H min

p-c control mode

Q

H

H max

Hs

H min

In this control mode (programmable only with the aid of the IR-Monitor)the electronic control will vary the setpoint level of the pump generated head depending on the measured fluid temperature. This control mode can be applied in conjunction with constant-volume (e.g. one-pipe) systems and variable-flow systems with modulating flow temperature control. The Dp-T control mode supports the condensing boiler technology, provided the pump is installed in the return pipe of the heating system. In addition, with optional Interface Modules the operational setpoints (head or RPM) can be adjusted externally from a 0 – 10V DC signal or a LONworks signal from a BMS system.

p-c control modeIn this control mode the electronic control will maintain the pump-generated head over the permissible flow rate range constant at the preset differential pressure setpoint level HS.

p-v control modeIn this control mode the electronic control will vary the pump-generated head linearly between HS and ½ HS. The differential pressure setpoint level H varies with flow rate Q.

WILO Stratos

WILO USA LLC1290 N 25th Ave. Melrose Park, IL601601-866-WILO-USAwww.WILO-USA.com

WILO Canada Inc.Bay #7 - 2915 10th Ave. NECalgary, AlbertaT2A 5L41-866-WILO-CDNWww.WILO-CANADA.com

Commercial High-Efficiency Circulators

Up to 80% Energy Savings!*

82

Page 87: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

WIL-SDS-STRD001-01-11

Project:

Engineer:

Contractor:

Submitted By: Date:

Approved By: Date:

Tag # Model # Flow Head Control Mode Cycle Phase Voltage

Stratos D 2x3-40 60Hz 1 230V

Stratos D 2x3-40

Submittal Data Sheet

Pump Volute Cast Iron (EN-GJL-250)Cataphoresis Coated

Impeller Composite (PPS-40% GF)

Shaft Stainless Steel (X46Cr13)

Bearing Metal Impregnated Carbon

Approval Stamp

Applications

Heating Systems Cooling Circuits

Air Conditioning Industrial Circulation

Solar Systems Geothermal Systems

Technical Data

Liquid Temp Range 14°F to 230°F (-10°C to 110 °C)

Max Temperature 104°F (40°C)

Min. Suction Pressure (122°F) 7.1 PSI

Min. Suction Pressure (203°F) 17.1 PSI

Min. Suction Pressure (230°F) 25.6 PSI

0 20 40 60 80 100 120

0 5 10 15 20 25 30

0 2 4 6 8

0

10

20

30

40

0

2

4

6

8

10

12

14

0 20 40 60 80 100 120

0 5 10 15 20 25 30

00,20,40,60,81,01,21,4

0

0,2

0,4

0,6

0,8

1,0

Q [USg.p.m.]

H [ft] H [m]

Q [m³/h]

Q [USg.p.m.]

Q [m³/h]

Wilo-Stratos-D 2x3-401 ~/ 60 Hz

min.

m in.

Δp-c

max.

max.

13 / '/4m81

6 /2m9 16/ '

'/1m13 /4

1911/ /6m16'3213/ /10m

16'261/ /8m

4'393 /12m'/ 8

Q [l/s]

P1[kW]P1[hp]

+

P1 Wilo-Stratos 2x3-40

0 20 40 60 80 100 120

0 5 10 15 20 25 30

0 2 4 6 8

0

10

20

30

40

0

2

4

6

8

10

12

14H [ft] H [m]

Q [m³/h]

Q [USg.p.m.]

Q [l/s]

0 20 40 60 80 100 120

0 5 10 15 20 25 30

00,20,40,60,81,01,21,4

0

0,2

0,4

0,6

0,8

1,0

Q [USg.p.m.]

Q [m³/h]P1[kW]P1[hp]

min.

max.

13 / '/4m81

1911/ /6m16'3213/

/10m16'

261/ /8m4'

Wilo-Stratos-D 2x3-401 ~/ 60 Hz

+

P1 Wilo-Stratos 2x3-40

Δp-v

max.

min.

Module 1 Module 2 Module

BACnet / Dual Pump

LONworks / Dual Pump

SBM Run Signal / Ext. Off / Dual Pump

SBM Run Signal / 0-10v / Dual Pump

Ext. Min / 0-10v / Dual Pump

Ext. Off / 0-10v / Dual Pump

83

Page 88: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

WIL-SDS-STRD001-01-11

Project:

Engineer:

Contractor:

Submitted By: Date:

Approved By: Date:

Tag # Model # Flow Head Control Mode Cycle Phase Voltage

Stratos D 2x3-40 60Hz 1 230V

Stratos D 3x3-40

Submittal Data Sheet

Pump Volute Cast Iron (EN-GJL-250)Cataphoresis Coated

Impeller Composite (PPS-40% GF)

Shaft Stainless Steel (X46Cr13)

Bearing Metal Impregnated Carbon

Approval Stamp

Applications

Heating Systems Cooling Circuits

Air Conditioning Industrial Circulation

Solar Systems Geothermal Systems

Technical Data

Liquid Temp Range 14°F to 230°F (-10°C to 110 °C)

Max Temperature 104°F (40°C)

Min. Suction Pressure (122°F) 10 PSI

Min. Suction Pressure (203°F) 21.3 PSI

Min. Suction Pressure (230°F) 32.7 PSI

0 100 200 300 400

400

0 20 40 60 80

0 5 10 15 20 25

0

10

20

30

40

0

2

4

6

8

10

12

14

100

100

0 100 200 300

0 20 40 60 80

0

1

2

3

4

0

0,5

1,0

1,5

2,0

2,53,0

H [ft] H [m]Q [m³/h]

Δp-c

max.

max.

13 / '/4m81

6 /2m9 16/ '

1911/ /6m16'3213/ /10m

16'261/ /8m

4'393 /12m'/8

Q [USg.p.m.]

Q [m³/h]

Q [l/s]

P1[kW]P1[hp]

Wilo-Stratos-D 3x3-401 ~/ 60 Hz

+

m in.

m in.

Q [USg.p.m.]

P1 Wilo-Stratos 3x3-40

0 100 200 300

0 5 10 15 20 25

100

0

10

20

30

40

0

2

4

6

8

10

12

0 100 200 300

400

400

0 20 40 60 80

0

1

2

3

4

0

0,5

1,0

1,5

2,0

2,53,0

H [ft] H [m]0 20 40 60 80 100Q [m³/h]

Δp-v

max.

max.

13 / '/4m811911/ /6m

16'3213/

/10m16'

261/ /8m4'

Q [USg.p.m.]

Q [m³/h]

Q [l/s]

P1[kW]P1[hp]

Wilo-Stratos-D 3x3-401 ~/ 60 Hz

+

m in.

Q [USg.p.m.]

P1 Wilo-Stratos 3x3-40

m in.

Module 1 Module 2 Module

BACnet / Dual Pump

LONworks / Dual Pump

SBM Run Signal / Ext. Off / Dual Pump

SBM Run Signal / 0-10v / Dual Pump

Ext. Min / 0-10v / Dual Pump

Ext. Off / 0-10v / Dual Pump

84

Page 89: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

1.5x

50

2x35

Wilo

-TO

P-S

1pha

se -

60H

z

010

020

4060

8010

0Q

[US

gpm

]

20304050

H[ft]

1.5x6

0

2x40

2x50

1.5x

40

2x25 1.5

x30

1.25x251.5x

20 1.25x35

1.25x15

010

040

8012

016

020

0Q

[US

gpm

]

20304060 50

H[ft]

Wilo

-TO

P-S

3pha

se -

60H

z

2x35

1.5x2

01.

25x3

52x

25

1.5x

30

2x40

2x50

3x70

1.5x

70

3x25

3x50

1.5x

4

1.5x

502x60

Two

Spee

dW

et R

otor

Circ

ulat

orTw

o Sp

eed

Wet

Rot

or C

ircul

ator

Top

S Th

ree

Phas

e Ci

rcul

ator

(208

/230

v, 4

60v,

575

v)To

p S

Sing

le P

hase

Circ

ulat

or(1

15v

or 2

30v)

E

C

D

1/4”

EC

1/4”

DE

C

1/4”

1/4”

D

1/4”

1/4”

EC

D

1/4”

C

1/4”

D

EC

DDra

win

g 1

Dra

win

g 3

Dra

win

g 5

Dra

win

g 2

Dra

win

g 4

Dra

win

g 6

85

Page 90: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

BUDERUSAM-10 QUICK REFERENCE SHEET

Wiring: There are three sets of terminals along the bottom of the control. THE BOTTOM OF THE CONTROL WILL END UP UPSIDE DOWN WHEN LOOKING at it from the front looking into the boiler. It mounts only this way.

Pair 1:

The pair all the way to the left accepts the little white plug that is lying in the rear of the boilers wiring harnesses to plug into. This is how it gets powered up and how it communicates to the GB-142’s circuit board.

Pair 2:

The middle pair: accept a thermostat connection from a regular thermostat or an end switch in a pump relay box or a zone control relay box.

Pair 3:

The right hand pair: accept the outdoor sensor wire. This is typically a pair of 18-2 thermostat wires running outside the building to a sensor mounted on the north side of the building.

Mode button: when depressed, moves the cursor from icon to icon

Icons and their meanings: From left to right are the… House, Radiator, Target adjustment, Basepointadjustment, and the Sun/Snowflake

The House icon is non-adjustable: Tells you the current outdoor temperature according to the outdoor sensor. This is true when the cursor is located above the icon in the LED display. The Mode button is what moves the cursor to the icon position.

The Radiator icon is non-adjustable and is referred to in the instruction manual as the FLOWTEMPERATURE SETPOINT and is the temperature that the boiler will target based on the outdoortemperature and the Setpoint adjustment temperature and the Basepoint settings.

The Target adjustment is adjustable and is the temperature you want the boiler supply temperature to be when the outdoor temperature is at 14 degrees Fahrenheit. For Baseboard, the typical temperature setpoint is 165 degrees Fahrenheit. Of course, the BC-10 or “Boiler Control” itself must be set for at least 180 degrees as the boiler sees what is set on the dial of the BC-10 as its high limit. The logic is that the burner will ride off of that point and modulate whenever the “Radiator” target nears that temperature.

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Buderus AM10 Quick Set UPPage 1

Michael Fox02/21/2007

86

Page 91: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

The Basepoint adjustment is adjustable and is simply the minimum supply temperature that you want the boiler to shoot for whenever the boiler has a call for heat and is below Warm Weather Shut Down.

Example of a need for a Basepoint: Baseboard heating elements work on convection and will not move air over their elements at a very fast pace if the difference in temperature between the element and the room is not large enough. What is large enough? Typically, if you have at least 100-110 degrees F, you CAN get heat out of baseboard.

Another example might be for an air handler with a Hydronic Coil which will feel like it has cold air blowing from it when the supply water temperature going to it is below 115 degrees Fahrenheit.

Sun/Snowflake: is simply your outdoor temperature shut down or Warm Weather Shut Down, otherwise referred to as your WWSD and will keep the boiler from turning on if the outdoor temperature is above this setting and there is a call for heat at the thermostat contacts on the center pair of the terminals on the AM-10 control module. This temperature is typically set at 68 degrees Fahrenheit.

Remember, Outdoor + Target adjustment + Basepoint = Radiator target temperature

Wrench icon: when seen in the LED display simply means that the boiler is locked out in fault mode.

Depending on the code you see (you must look up the code in the Boiler installation Instruction Booklet under Troubleshooting), the boiler may or may not run. For instance, if the control doesn’t see an outdoor sensor, it will have three flat lines across the LED display like this - - - and will only let the boiler run until the supply temperature is 122 degrees F.

The “Heat Call” Icon is what will appear in the LED display whenever there is a call for heat.

The “Flame” Icon is what you will see when the burner is running. It is black in color.

For more information, refer to the manual. For issues beyond that call Buderus Technical Support at 603-552-1100 or Capco Energy Supply Inc. @ 781-721-0303.

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COM

THIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VERIFIED AND ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR

10 INDUSTRIAL PARKWAYWOBURN MA 01801

ENERGY SUPPLY, INC.

Buderus AM10 Quick Set UpPage 2

Michael D. Fox02/21/2007

BUDERUS

AM10 QUICK SET UP (CONT”D)

87

Page 92: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Technical Service Bulletin:

FW 200 Control Quick Start GuideModels: Bosch Greenstar Combi 151/100, Bosch Greenstar 151/131/100/57

This is a quick reference to highlight the BASIC programming of this control. For a more in depth understanding or complete programming of the control, please refer to the FW 200 Installation and Operating manuals.

At any time, pressing the Menu button (Fig.1, pos.3) will bring you back to the standard display.

Instructions for programming

Set Date and Time upon initial start-up

— Turn dial (Fig.1, pos.1) to adjust time and date. Press the dial to nalize your selection.

— You will be asked about System con guration, which is only necessary if you have added additional controls. If you see this prompt, press and hold the menu button (Fig.1, pos.3) until it disappears.

Set Date and Time after intitial programming

— Push the menu button once and release. On the display Vacation will be highlighted.

— Turn dial counter-clockwise until General Settings is highlighted.

— Push dial once and release. Time and Date will be highlighted.

— Push dial again and Time will be highlighted. Set time by pushing dial and rotating. Once complete, push again to lock in time setting.

— Turn dial until Date is highlighted. Set date by pushing dial and turning to select. Push dial once to lock in date setting.

1

2

3

4

5

6

9 15

18

24h3

6

1

2

3

4

5

6

9 15

18

24h3

6

Figure 1

* Controller with front ap open

Set for constant heating (no night set back)

This can be done two ways:

1) Turn selector (Fig.1, pos.2) to the Comfort Symbol ( ).

2) Or change programming.

To change programming:

— Press and release menu button. Vacation will be highlighted.

— Turn dial one click counter-clockwise to highlight Heating and push dial to select.

— Program will be highlighted. Push dial to select.

— Activate will be highlighted. Turn the dial one click to highlight Edit and push dial to select.

— Program A will be highlighted. Push dial to select.

88

Page 93: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

| | |

Technical Service Bulletin2 | FW 200 Control Quick Start Guide

Bosch Thermotechnology Corp.50 Wentworth AvenueLondonderry, NH 03053

Tel: 1-800-283-3787Fax: (603) 965-7568www.bosch-climate.us

— Replace with preset program will be highlighted. Turn the dial counter-clockwise to display All days and push dial to select.

— P1 will be highlighted. Press the dial again and the display will ash.

— Turn dial one click clockwise to 12:00PM.

— Press the dial and rotate it until Comf. appears. The area around the display should fill in.

— Press dial again to lock in your program.

— Press the menu button to return to main display.

Set type of heating system

There are three seperate default presets: Baseboard, Radiators, Radiant Floor. They have an approximate basepoint of 75°F. With this basepoint, the heating system will take some time to raise the room temperature in warmer weather. Please see the FW200 ISM, Sec. 8.3.2 for more details on those presets. For a custom preset, see below.

— Press and hold the menu button for about 5 seconds.

— System Con guration will be highlighted.

— Turn dial one click counter-clockwise to highlight Heating Parameters. Push dial to select.

— Heating Circuit 1 will be highlighted Press dial again and Heating circuit type will be highlighted.

— Press dial and Radiators will be highlighted. Press dial again and Radiators will ash.

— Turn the dial to choose Baseline/Design temp and push dial to select.

— Heating circuit type will again be highlighted. Rotate the dial counter-clockwise.

— Base Line will be displayed. Press the dial and 78°F will ash. This is your minimum supply temperature at 14°F

outdoor temperature. Set accordingly and press dial once to lock in the setting.

For hydroair systems, the minimum supply temperature must be raised to the turn on temperature for that coil.

— Rotate dial and Design Temp will be highlighted. Press the dial and 168°F will ash.

— Use tables 1 & 2 to choose which temperature to enter. Set accordingly and press dial once to lock in the setting.

Refer to manual for more custom settings.

Table 1

90°F basepointDesign Temp (°F)

10 0 -10

DesiredSupply Temp (°F)

180 176 158 150

160 156 144 138

140 134 128 122

Table 2

80°F basepointDesign Temp (°F)

10 0 -10

DesiredSupply Temp (°F)

140 134 124 110

120 118 110 106

100 98 95 92

— Rotate the dial counter-clockwise to display Maximum heating supply temperature. Press the dial and adjust as desired. Push dial once to lock in the setting.

— Press the menu button to return the main screen.

Adjust warm weather shut down (WWSD)

— Press and hold the menu button for about 5 seconds. System Con guration will be highlighted.

— Turn dial one click counter-clockwise to highlight Heating Parameters and push dial to select.

— Heating Circuit 1 will be highlighted.

— Turn the dial counter-clockwise until Heating OFF at outdoor temperature is displayed. The default is 68°F and is adjustable from 37°F to 77°F. Turning above 77°F will move it to 210°F, which disables WWSD. Push dial once to lock in the setting.

To restore to factory defaults, hold the Delete button (Fig.1, pos.5) and the Menu button simultaneously for about 10 seconds. A count down display will appear. This will restore factory defaults. The only program that will be held is the date and time.

89

Page 94: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

This

is a

con

cept

ual d

raw

ing

only

and

doe

s no

t rep

rese

nt a

ll sa

fety

con

trols

whi

ch m

ay b

e re

quire

d.

The

inst

allin

g co

ntra

ctor

is re

spon

sibl

e fo

r the

saf

e in

stal

latio

n of

fuel

bur

ning

equ

ipm

ent.

The

desi

gner

mus

t det

erm

ine

if a

sugg

este

d sy

stem

will

wor

k in

his

/her

app

licat

ion

and

add

the

nece

ssar

y is

olat

ion

valv

es, s

afet

y de

vice

s, a

nd m

odifi

catio

ns w

hich

may

be

requ

ired

by lo

cal a

utho

ritie

s.

372

Uni

vers

ity A

ve.

Wes

twoo

d, M

A 0

2090

P: 7

81-3

20-9

910

F: 7

81-3

20-9

906

HB

X

TYPI

CA

L PR

OG

RA

MM

ING

SET

TIN

GS:

DE

SIG

N B

OIL

ER

TEM

P:

SET

AT1

80°F

(FO

R E

FFIC

IEN

T B

OIL

ER O

PER

ATIO

N

THIS

CA

N B

E L

OW

ER

ED

BU

T M

US

T B

E

HIG

HE

R T

HAN

“RA

DIA

NT

DES

IGN

W

ATE

R T

EMP”

)

MIX

ING

VA

LVE

SE

TTIN

G:

KEE

P O

N!

TEM

PER

ATU

RE:

FAH

RE

NH

EIT

OR

CE

LSIU

S

PE

RM

ANEN

T H

EAT

DEM

AND

:

US

ING

NO

RO

OM

T-S

TAT

= O

N

US

ING

RO

OM

T-S

TAT

= O

FF

WA

RM

WE

ATH

ER

SH

UT

DO

WN

:

SE

T A

T 70

°F

NO

TE: D

EVIC

E W

ILL

NO

T FU

NC

TIO

N IF

OU

TDO

OR

TE

MP

IS

ABO

VE T

HIS

TE

MP

.

BO

ILER

DIF

FER

EN

TIA

L TE

MP

:

SE

T A

T 20

°F

RAD

IAN

T M

INIM

UM

WAT

ER

TEM

P:

SE

T AT

90°

F FO

R S

TAP

LE U

P

SE

T AT

80°

F FO

R IN

SU

B FL

OO

R

SE

T AT

75°

F FO

R IN

SLA

B

BO

ILE

R P

RO

TEC

TIO

N T

EM

P

SE

T A

T 50

°F F

OR

CO

ND

EN

SIN

G

BO

ILE

R

SE

T A

T 13

5°F+

FO

R C

AST

IRO

N

BO

ILE

R

NO

TE: I

F B

OIL

ER

TE

MP

SE

NS

OR

R

EA

DS

BE

LOW

TH

IS T

EM

P TH

E

DE

VIC

E W

ILL

NO

T FU

NC

TIO

N

(PR

OTE

CTI

NG

BO

ILE

R)

DE

SIG

N O

UTD

OO

R T

EM

P:

SET

AT

0°F

DES

IGN

RO

OM

TE

MP

:

SE

T A

T 70

°F

RAD

IAN

T D

ES

IGN

WA

TER

TE

MP

:

SE

T AT

145

°F F

OR

STA

PLE

UP

SE

T AT

135

°F F

OR

IN S

UB

FLO

OR

SE

T AT

115

°F F

OR

IN S

LAB

90

Page 95: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

3 3

to 185 F

120 Fw/ ecm

130 F to 150 FAquastat

to 185 F

91

Page 96: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Use only as a guide. Please follow manufacturers installation and service manuals

92

Page 97: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

93

Page 98: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

94

Page 99: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

5600 3

36

v1.0

CombiPLUS Kit for Vitodens 100-W, WB1B Quick Start Operation

Programming

1

2

3

4

Programming the boiler control for operation with or without the CombiPLUS.

Note: If an optional CombiPLUS is used, the boiler control must be programmed.

For additional programming refer to the boiler Operating, Installation and Service Instructions.

1 Lift flap and pull control unit cover down. All boiler controls are located behind the control unit cover.

2 Simultaneously turn rotary selectors “ “ and “tr“ to their central position. “SERV + “ will appear on the screen.

Note: If one (or both) of the rotary selector dials are already in the central position, take it (or them) out of the central position and then simultaneously turn both rotary selectors back to the central position.

3 Turn the rotary selector “ “ fully to the right. “ “ will appear on the display.

4 Adjust the control by turning the rotary selector “tr“. The display shows: “0” or “1” flashing “1” boiler with the optional CombiPLUS. “0” boiler without optional CombiPLUS (factory default setting).

Note: After programming the boiler control to accept the CombiPLUS, wait until the boiler temperature is displayed, then switch the control OFF then ON. ECO will be displayed on the screen.

g g

95

Page 100: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

96

Page 101: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

97

Page 102: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

98

Page 103: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

99

Page 104: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

100

Page 105: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Stratos “Quick Start” ManualStratos guide d’installation rapideStratos Manual rápido de Comienzo

WILO USA LLC1290 North 25th AvenueMelrose Park, Illinois 60160Phone: 866 945 6872 Fax: 708 338 9455

www.WILO-NA.com

WILO Canada IncBay 7 - 2915 - 10th Ave N. E.

Calgary, Alberta, T2A 5L4Phone: 866 945 6236 Fax: 403 277 9456

Troubleshooting Cause RemediesElectric fuse faulty Check fusePump has no power Rectify interruption to powerCavitation due to insufficient Increase system admission pressureadmission pressure within permissible range

Check pump lift setting, set lower liftif necessary

10.1 Error messages: Error LED "permanent light"

Code Symbol Problem Cause RemediesNumber Flashing

E04 Supply Mains undervoltage Mains overloaded Check electrical Installationterminal

E05 Supply Mains overvoltage Check electrical Installationterminal

E10 Motor Pump blocked e.g. sedimentation De-blocking routine starts automaticallyShould this not remove the blockage, thepump switches off after 10 secCall customer service

E20 Motor Winding overheated Motor overloaded Let motor cool down, check the settings. Ambient temperature too high Reduce water temperature

E21 Motor Motor overload Sediment in the pump Call customer serviceE23 Motor Short circuit / contact Motor defect Call customer service

faultE25 Motor Contact error Module not correctly installed Reinstall moduleE30 Module Excess temperature module Air intake to module heat sink is blockedE31 Module Excess temperature Ambient temperature too high Improve ventilation in room

power componentE36 Module Module faulty Electronic components Faulty Call customer service / swap module

10.2 Warning messages: Error LED "off"Code Symbol Problem Cause Remedies

Number FlashingE03 Water temperature >110°C Heating control incorrectly set Set to lower temperatureE04 Mains undervoltage Mains overloaded Check electrical installationE05 Mains overvoltage Check electrical installationE07 Generator operation Driven by admission pressure pump Balance pump capacity regulationE09 Generator operation Driven by reverse flow through "off" pump Check circulation Direction.

Fit a check valve at the pressure side. E11 Pump idling Air in the pump Vent pump and unitE38 Motor Temp. sensor medium faulty Motor faulty (auto night setback) Call customer servicesE51 Non-Permissible Combination Different pumpsE52 Master/Slave communication Stratos IF module not correctly After 5 mins, the modules switch to

error. Pump switched from positioned, cable faulty. standard mode to fixed check cables. characteristic (depending onchosen set value)

MA Master/Slave not set Specify master and slave

If the fault cannot be remedied, please contact your local heatingspecialist or WILO customer services.

ProblemPump does not run with power on

Noisy pump operation

101

Page 106: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Residential Models and Packages

EXTROL®

• Factory pre-charged to 12 psig

• Maximum working pressure: 100 psig

• Maximum operating temperature: 240°F

EXTROL Specifications

For Radiant Systems, Use RADIANT EXTROLTM

• Specifically designed for high-efficiency radiant systems• Plastic liner compatible with barrier and non-barrier systems• Suitable for use in glycol applications• Non-ferrous system connection for corrosion resistance• Maximum working pressure: 100 psig• Maximum operating temperature: 200°F

EXTROLPackage

RADIANT EXTROL

RADIANT EXTROL Tanks for Radiant Systems

1 System Connection is NPTM

1 System Connection is NPTM

Sizing the EXTROLSizing Based on BTU’s

Sizing based on: • Fill Pressure 12 psig • Relief Pressure 30 psig • Average System Temp. 200°F• System filled with water • Consult factory for compatibility and sizing for other fluids.

BOILER TYPE OF RADIATIONNet Output Finned Tube Convectorsin 1000'S Baseboard or or Unit Radiators Baseboardof BTU/Hr. Radiant Panel Heaters Cast Iron Cast Iron

MBH Use Model Use Model Use Model Use Model

25 15 15 15 15

50 15 15 30 30

75 30 30 30 60

100 30 30 60 60

125 30 60 60 90

150 30 60 90 90

175 60 60 SX-30V SX-30V

200 60 60 SX-30V SX-30V

250 60 90 SX-30V SX-40V

300 90 SX-30V SX-30V SX-40V

350 SX-30V SX-30V SX-40V SX-60V

400 SX-30V SX-40V SX-40V SX-60V

EXTROL Combination Packages

Sizing Based on Maximum System Temperature

Sizing by system temp. based on: • Max. Operating Temperature 240°F • Fill Pressure 12

psig • Relief Pressure 30 psig • Water Fill Temperature 40°F

Max. System System Water Content in GallonsTemp. °F Model 15 Model 30 Model 60 Model 90

100 125 275 417 876110 93 205 311 653120 72 158 239 502130 58 128 194 407140 48 105 160 336150 40 89 134 282160 34 76 115 241170 30 65 99 208180 26 57 87 182190 23 51 77 161200 20 45 68 143210 18 40 61 129220 17 37 55 116230 15 33 50 106240 14 30 46 96

Model Tank Max. Accept. A B System ShippingNumber Volume Volume Height Diameter Conn.1 Weight

(Gallons) (Gallons) (Inches) (Inches) (Inches) (lbs.)

15 2.0 0.9 12 5⁄8 8 1⁄2 5

30 4.4 2.5 15 1⁄2 11 1⁄2 9

60 7.6 2.5 23 11 1⁄2 14

90 14.0 11.3 21 15 3⁄8 1⁄2 23

Model Extrol Purger Vent Ship. Wt.Number Model Model Model (lbs.)

1500/1 or 1 1⁄4 15 443 or 444 700-C 9

3000/1 or 1 1⁄4 30 443 or 444 700-C 14

6000/1 1⁄4 60 444 700-C 19

6000/1 1⁄2 60 445 700-C 19

Model Tank Max. Accept. A B System ShippingNumber Volume Volume Height Diameter Conn.1 Weight

(Gallons) (Gallons) (Inches) (Inches) (Inches) (lbs.)

RX-15 2.0 0.9 12 5⁄8 8 3⁄4 5

RX-30 4.4 3.2 15 1⁄2 11 3⁄4 9

RX-60 10.3 10.3 19 1⁄4 15 3⁄8 1 23

Radiant Extrol Quick Sizing ChartFeet of Nominal Pex Tubing SizeTubing 3/8" 1/2" 5/8" 3/4" 1"1000 RX-15 RX-15 RX-15 RX-15 RX-155000 RX-15 RX-15 RX-15 RX-30 RX-307500 RX-15 RX-15 RX-30 RX-30 RX-6010000 RX-15 RX-30 RX-30 RX-60 RX-6014000 RX-15 RX-30 RX-60 RX-6018000 RX-30 RX-60 RX-60 RX-6022000 RX-30 RX-60 RX-6030000 RX-30 RX-60

Based on 120°F operating temp. with 12psi fill and 30psi relief valve.For glycol applications, consult AMTROL Technical Support.

See Precise Sizingon back page.

102

Page 107: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

BoilerFinned Tube

BB or Radiant Panels

Convectors or Unit Heaters

Radiators (One Pipe)

Radiators (Series Loop)

Use Model Use Model Use Model Use Model200 D-40V D-40V D-40V D-40V250 D-40V D-40V D-40V D-40V300 D-40V D-40V D-40V D-40V350 D-40V D-40V D-40V D-60V400 D-40V D-40V D-60V D-60V450 D-40V D-60V D-60V D-120V500 D-40V D-60V D-60V D-120V550 D-40V D-60V D-60V D-120V600 D-40V D-60V D-120V D-120V650 D-60V D-60V D-120V D-120V700 D-60V D-60V D-120V D-120V750 D-60V D-60V D-120V D-120V800 D-60V D-120V D-120V D-120V850 D-60V D-120V D-120V D-120V900 D-60V D-120V D-120V D-120V950 D-120V D-120V D-120V D-120V1000 D-120V D-120V D-120V D-120V1100 D-120V D-120V D-120V D-240V1200 D-120V D-120V D-120V D-240V1300 D-120V D-120V D-240V D-240V1400 D-120V D-120V D-240V D-240V1500 D-120V D-120V D-240V (2) D-120V

Type of Radiation & Piping System

Net Output in MBH

Bell & Gossett Commercial ASME Expansion Tank Quick Sizing Guide

- Factory pre-charged to 12 psig- Pre-charge should be adjusted to equal minimum operating pressure @ tank location- Maximum working pressure: 125 psig- Maximum operating temperature: 240F

PART NUMBER

MODEL NUMBER

TANK VOLUME

ACCEPTANCE VOLUME

A DIAMETER (INCHES)

B HEIGHT

(INCHES)

APPROX. WEIGHT (LBS.)

116493 D-40V 21.7 29 1/2 90

116525 D-60V 33.6 45 1/8 110

116528 D-120V 68 34 24 43 7/8 224

116532 D-240V 132 46 30 53 1/2 427

11.3 16 1/4

7 Sixth Road - Woburn, MA - 01801 - Phone: (800) 423-7187 - Fax: (781) 933-3965FIA - Fluid Industrial Associates Inc. - New England’s premier plumbing, HVAC, radiant heating, and snow melting manufacturers representative

These recommendations are calculated on average boiler water volumes and the average water volumes of currently poplular types of radiation and piping systems. The industry operating standards of 12 psig fill pressure and 30 psig relief pressure are used.

103

Page 108: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Precise Sizing

Part # 9003-031 Rev. B MC# 2680 (9/05) ©2005 AMTROL Inc.P i t d i USA

The AMTROL® logo EXTROL® Therm-X-Trol® and Fill-Trol® are registered trademarks of AMTROL Inc. In the interest of continuous development, AMTROL Inc. and it’s subsidiaries reserve the right to alter designs and specificationswithout prior notice.

Corporate Headquarters1400 Division Road, West Warwick, RI USA 02893Telephone: 401-884-6300 • Fax: 401-884-5276

AMTROL Canada, Ltd.275 Shoemaker Street, Kitchener, Ontario N2E 3B3Telephone: 519-478-1138 • Fax: 519-748-4231

w w w . a m t r o l . c o m

Table 1. Net Expansion of WaterMax.Sys. Minimum System Temperature °FTemp. °F 40°F 50°F 60°F 70°F 80°F 90°F 100°F

60°F .0005 .0049 — — — — —

70°F .00149 .00143 .00094 — — — —

80°F .00260 .00254 .00204 .00111 — — —

90°F .00405 .00399 .00350 .00256 .00145 — —

100°F .00575 .00569 .00520 .00426 .00315 .00170 —

110°F .00771 .00765 .00716 .00622 .00511 .00366 .00196

120°F .0100 .0099 .0095 .0086 .0074 .0060 .0043

130°F .0124 .0123 .0118 .0109 .0098 .0083 .0066

140°F .0150 .0149 .0145 .0135 .0124 .0110 .0093

150°F .0179 .0178 .0173 .0164 .0153 .0133 .0121

160°F .0209 .0208 .0204 .0194 .0181 .0165 .0148

170°F .0242 .0241 .0236 .0227 .0216 .0201 .0184

180°F .0276 .0275 .0271 .0261 .0250 .0236 .0219

190°F .0313 .0312 .0307 .0298 .0287 .0272 .0255

200°F .0351 .0350 .0346 .0336 .0325 .0311 .0294

210°F .0391 .0390 .0386 .0376 .0365 .0351 .0334

220°F .0434 .0433 .0428 .0419 .0408 .0393 .0376

230°F .0476 .0475 .0471 .0461 .0450 .0436 .0419

240°F .0522 .0521 .0517 .0507 .0496 .0482 .0465

Note: For ethylene glycol and for propylene glycol contact AMTROL technical services.

Things you must know:1. Total System Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . .(1)_____ gallons

2. Minimum System Temperature . . . . . . . . . . . . . . . . . . . .(2)_____°F

3. Maximum System Temperature . . . . . . . . . . . . . . . . . . .(3)_____ °F

4. Minimum Operating Pressure at Expansion Tank . . . . . .(4)_____ psig

5. Maximum Operating Pressure at Expansion Tank . . . . .(5)_____ psig

Selection of Expansion Tank:6. Find and enter "Net Expansion Factor" . . . . . . . . . . . . . . . .(6)_____ (see table 1)

7. Amount of Expanded Water = line (1) x line (6) . . . . . . . . . .(7)_____ gallon

8. Find and enter "Acceptance Factor” . . . . . . . . . . . . . . . . . .(8)_____ (see table 2)

9. Minimum Total Tank Volume = line (7) ÷ line (8) . . . . . . . . . .(9)_____ gallons

10. Using Specifications on pages 6 and 7, select an Expansion Tank that is atleast equal to line (9) for "Total Volume" and line (7) for Max. Expanded WaterAcceptance Gallons. Mulitiple tanks may be required.

Precise Sizing of EXTROL® & RADIENT EXTROLTM

Table 2. Acceptance Factors*Max.Oper. Minimum Operating Pressure at Tank (psig)Pressure atTank (psig) 5 10 12 15 20 30 40 50 60 70 80

27 0.527 0.408 0.360 0.288 0.168 — — — — — —

30 0.560 0.447 0.403 0.336 0.224 — — — — —

35 0.604 0.503 0.463 0.403 0.302 0.101 — — — — —

40 0.640 0.548 0.512 0.457 0.366 0.183 — — — — —

45 0.670 0.586 0.553 0.503 0.419 0.251 0.084 — — — —

50 0.696 0.618 0.587 0.541 0.464 0.309 0.155 — — — —

55 0.717 0.646 0.617 0.574 0.502 0.359 0.215 0.072 — — —

60 0.736 0.669 0.643 0.602 0.536 0.402 0.268 0.134 — — —

65 0.753 0.690 0.665 0.627 0.565 0.439 0.314 0.188 0.062 — —

70 0.767 0.708 0.685 0.649 0.590 0.472 0.354 0.236 0.118 — —

75 0.780 0.725 0.702 0.669 0.613 0.502 0.390 0.279 0.167 0.056 —

80 0.792 0.739 0.718 0.686 0.634 0.528 0.422 0.317 0.211 0.106 —

90 0.812 0.764 0.745 0.716 0.669 0.573 0.478 0.382 0.287 0.191 0.096

100 0.828 0.785 0.767 0.741 0.698 0.610 0.523 0.436 0.347 0.261 0.174

110 0.842 0.802 0.786 0.762 0.723 0.642 0.561 0.481 0.401 0.321 0.241

* Acceptance factors based on expansion tank being charged to minimum operating pressure while empty of liquid.

104

Page 109: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

Pipe Volumes In Gallons Per FootUse for Anti-freeze Calculations

Gallons/ftType Nominal Pipe Diameter ID " Area sq. in. Volume cu in / ft Multiplier

Copper 1/4" 0.305 0.07 0.88 0.0038Copper 3/8" 0.402 0.13 1.52 0.0066Copper 1/2" 0.527 0.22 2.62 0.0113Copper 5/8" 0.652 0.33 4.01 0.0174Copper 3/4" 0.745 0.44 5.23 0.0227Copper 1" 0.995 0.78 9.33 0.0404Copper 1 1/4" 1.245 1.22 14.62 0.0633Copper 1 1/2" 1.481 1.72 20.68 0.0895Copper 2" 1.959 3.02 36.19 0.1566Copper 2 1/2" 2.435 4.66 55.91 0.2420Copper 3" 2.907 6.64 79.68 0.3449Copper 3 1/2" 3.385 9.00 108.04 0.4677Copper 4" 3.857 11.69 140.27 0.6072

PEX 5/16" 0.292 0.07 0.80 0.0035PEX 3/8" 0.35 0.10 1.16 0.0050PEX 1/2" 0.475 0.18 2.13 0.0092PEX 5/8" 0.574 0.26 3.11 0.0134PEX 3/4" 0.671 0.35 4.25 0.0184PEX 1" 0.862 0.58 7.01 0.0303PEX 1 1/4" 1.053 0.87 10.45 0.0453PEX 1 1/2" 1.243 1.21 14.57 0.0631

Steel 3/8" 0.493 0.19 2.29 0.0099Steel 1/2" 0.622 0.30 3.65 0.0158Steel 3/4" 0.824 0.86 10.38 0.0449Steel 1" 1.049 1.50 17.96 0.0777Steel 1 1/4" 1.38 1.50 17.96 0.0777Steel 1 1/2" 1.61 2.04 24.44 0.1058Steel 2" 2.067 3.36 40.29 0.1744Steel 2 1/2" 2.469 4.79 57.48 0.2488Steel 3" 3.068 7.40 88.75 0.3842Steel 4" 4.026 12.74 152.83 0.6616Steel 5" 5.047 20.01 240.18 1.0397Steel 6" 6.065 28.90 346.84 1.5015

Multiply total length of piping in ft. by gallons per foot multiplier.This will give you total volume of liquid content in piping. Multiply by % of glycol desired to determine gallons of anti-freeze needed.

105

Page 110: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

CONVERSIONSCONVERSION FACTORS

1 U.S. Gallon Equals 231 Cubic Inches 1 Cubic Foot Equals 7.48 U.S. Gallons0.1337Cubic Feet 0.0283 Cubic Meters3.785 Liters0.833 Imperial Gallons 1 Liter Equals 0.264 U.S. Gallons

1 Imperial Gallon Equals 1.2 U.S. Gallons 1 Cubic Meter Equals 35.314 Cubic Feet264.2 U.S. Gallons

999.97 Liters

CONVERSIONS

To Convert This… To This.. Multiply by This…

P(kW) HP kW x 1.34=Kilowatts Horsepower kW ÷ .746=BAR PSI Absolute (PSIA)Of Pressure Pound per square inch of BAR x 14.5 + 14.7=

pressure(includes atmospheric pressure at sea level)

BAR PSI Gauged (PSIG)Of Pressure Pounds per square inch of

pressure as it would be read BAR x 14.5 =on a pressure gauge (does notinclude atmospheric pressure)

PSIG Gauge Pressure Head, Feet PSI x 2.31 ÷ SP.GR=Head, Feet PSIG Gauge Pressure Muliply by .4328Millimeters Inches (mm) x .0394=Meter Feet (Meters) x 3.28=Centimeters Inches Centimeters ÷ 2.54=° C ° FDegree's Celsius Degree's Fahrenheit ° C (9/5) + 32=° F ° CDegree's Fahrenheit Degree's Celsius (F-32) ÷ 1.8Watts Horsepower Watts x .001341=Watts Btu/hr

British Thermal Units Per Hour Watts x 3.4127=kW Btu/hr 3412 BTU's=1 kWBoiler Horsepower Btu/hr Boiler Hp x 33479=GPM Liters per second (l / s) 0.06309GPM Liters per minute (l / min) 3.7854

106

Page 111: TOC Pages from Hydronic Book 2013 - Capco Supply Eco Pump Specifications ... Viessmann WB2B Quick Start-up Sheet ... timer to run only during times of expected hot water

10 Industrial Parkway, Woburn, MA 01801 781-721-0303 Fax 781-721-9119 www.capcosupply.com

BOILERS HEATING SPECIALTIES PLUMBING SPECIALTIESBosch General / Garber Oil Filters Aquatherm Pipe

Buderus Lenox Tools Ridgid ProPress

Lochinvar Pipe Insulation Viega PureFlow

Viessmann Raywal

Ridgid Tools RADIANT FLOOR HEATINGBURNERS Tiger Loop Crete Heat

Beckett Winter Gauges Radiant Tarp

Buderus Viega ProRadiant

Carlin HVACRiello Aprilaire RADIATIONViessmann Century Air Handler Buderus

Century Condenser Haydon

CIRCULATORS First Company Myson

Bell & Gossett General Air Humidifiers Runtal

Grundfos Heatpack Coils Schwank

Taco Lifebreath / Nutech

Wilo Modine SOLARQuiet One Apricus

COMMODITIES Soler & Palau Buderus

Black Steel Nipples Unico Caleffi

Black Steel Pipe SuperStor

Brass Fittings & Nipples HYDRONICS SPECIALTIES Viessmann

Cast Iron Fittings AIC Heat Exchangers

Copper Manifolds Apollo Valves TESTING EQUIPMENTCopper Tubing & Fittings Axiom E-Instruments

2013 Stock Card

Malleable Fittings Bell & Gossett UEI

Pipe Hangers Caleffi

Smoke Pipe Cryo-tek THERMOSTATSThreaded Rod Danfoss Honeywell

Ecoflex Tekmar

CONTROLS FlatPlate

HBX McDonnell & Miller VENTING PRODUCTSHoneywell Oventrop Centrotherm

Ranco ETC Controls P.A.W. FasNflex

Taco Rhomar FasNseal

Tekmar Sparco / Honeywell Field

Taco Hart & Cooley

GEOTHERMAL Watts Protech

Charter Plastics Webstone Valves

Heat Controller WATER HEATERSBosch OIL TANKS Bosch

Highland Buderus

Roth Lochinvar Squire

SuperStor

Turbomax

Viessmann