tornier blueprint - emedia › productfiles › files › pdfs › caw-7493_en_… · the glenoid...
TRANSCRIPT
10801 Nesbitt Avenue SouthBloomington, MN 55437888 867 6437952 426 7600www.tornier.com
Take back control.
TORNIER
BLUEPRINT3D Planning + PSI
Access your planning solution at tornierBLUEPRINT.com
B L U E P R I N T™ 3 D P L A N N I N G + P S I
Take back control.
TORNIER
3D Planning + PSIBLUEPRINT™
BLUEPRINT™ a patient-specific shoulder instrument system
that delivers control of pre-operative planning directly to the
surgeon’s computer. No corporate middleman. No delays.
Just you, your patient, and support from a full team of
Wright specialists. Take back control.
Access your planning solution at tornierBLUEPRINT.com
+
Surgeon-Controlled 3D Planning Software:• Places the power of case planning and decision-making directly at the surgeon’s fingertips.
• Enables immediate case planning and guide ordering. No corporate middleman. No delays.
• Patient-specific guides precisely transfer the pre-clinical plan to the operating room.
Using a BLUEPRINT™ patient-specific glenoid guide enables the surgeon to more accurately position
the glenoid implant and replicate the pre-operative surgical plan compared to standard techniques.1,2
Patient-Specific Accuracy
B L U E P R I N T™ 3 D P L A N N I N G + P S I
Access your planning solution at tornierBLUEPRINT.com
2.9mm
11.1°
10.7°
GLENOID BONE REMOVAL (mm3)
ARTHRITIC GLENOID CURVATURE RANGE
PerFORM GLENOIDTRADITIONAL GLENOID
30mm 40mm 50mm 60mm
1.05mm
1.64°
1.42°
2.9mm
11.1°
10.7°
GLENOID BONE REMOVAL (mm3)
ARTHRITIC GLENOID CURVATURE RANGE
PerFORM GLENOIDTRADITIONAL GLENOID
30mm 40mm 50mm 60mm
1.05mm
1.64°
1.42°
Version
Inclination
Standard Instrumentation
Entry Point
1.64°
1.42°
1.05 mm 2.9 mm
11.1°
10.7°
TORNIER
BLUEPRINT3D Planning + PSI
™
Access your planning solution at tornierBLUEPRINT.com
B L U E P R I N T™ 3 D P L A N N I N G + P S I
Using surgeon-controlled BLUEPRINT™ with the AEQUALIS™ PERFORM™ glenoid combines
accurate component positioning with glenoid bone preservation.
Implant Accuracy + Bone Preservation
Access your planning solution at tornierBLUEPRINT.com
Arthritic Glenoid Curvature Range
30 mm 40 mm 50 mm 60 mm
Glenoid Bone Removal (mm3)
AEQUALIS™ PERFORM™ Glenoid
Traditional Glenoid
PA
A
A
+
AEQUALIS™ PERFORM™ glenoid preserves up to 68% more bone when compared to traditional glenoid systems.3
Access your planning solution at tornierBLUEPRINT.com
™ and ® denote Trademarks and Registered Trademarks of Wright Medical Group N.V., or its affiliates.©2016 Wright Medical Group N.V. or its affiliates. All Rights Reserved.
CAW-7493 rev B ECN 160088 14-Jan-2016
10801 Nesbitt Avenue SouthBloomington, MN 55437888 867 6437952 426 7600www.tornier.com
1023 Cherry RoadMemphis, TN 38117800 238 7117901 867 9971www.wright.com
References1. Gilles Walch, MD, Peter S. Vereridis, MD, Pascal Boileau, MD, Pierric Deransart, M. Eng, Jean Chaoui, PhD. Three-dimensional planning and use of
patient-specific guides improve glenoid component position: an in vitro study.2. Joseph Iannotti, MD, PhD, Justin Baker, PhD, Eric Rodriguez, BS, John Brems, MD, Eric Ricchetti, MD, Mena Mesiha, MD, and Jason Bryon, MS.
Three-dimensional preoperative planning and a novel information transfer technology improve glenoid component positioning.3. Tornier Data on File.
For more information and to register for BLUEPRINT,™ please visit: tornierBLUEPRINT.com