tricon/e 3 transmitter - meter, valve and...

2
PRODUCT SHEET TRICON/E ® 3 TRANSMITTER KEY FEATURES Electronic pulse output proportional to the meter’s rate of flow Electronic pulse output available with 4–20mA analog output or high frequency forward/reverse pulse output Mounts between the meter and register – Direct Read, ARB ® , ProRead , E-Coder ® , or E-Coder)R900i Utilizes dual optical switch type design which is more accurate and reliable than the older single optical switch designs Stainless steel ball bearings minimize torque Tamperproof seal pin to prevent unauthorized access In-line adaptability allows installation or service without interrupting the meter service WARRANTY An electronic digital pulse output with the 4–20mA analog option is available for customers requiring both digital and analog outputs. Reverse flow indication is available with the high frequency forward/reverse pulse output option. The TRICON/E3 transmitter mounts between the meter maincase and the register. The bayonet-type mount allows the TRICON/E3 to be easily retrofitted to many existing Neptune meters without interruption. Contact Neptune regarding compatibility. The TRICON/E3 with the 4–20mA analog option provides an analog signal that is proportional to the flow. Together, the digital pulse signal and the 4–20mA analog output provide information on total consumption and flow rate for close monitoring of water usage. The TRICON/E3 with the high frequency forward/reverse pulse output option can be used in applications where directional flow monitoring is required in addition to total consumption and flow information. Every Neptune meter meets or exceeds the latest AWWA standards ensuring accurate, dependable performance. Neptune TRICON/E3 units are ideally suited for monitoring/controlling total flow rate data such as: Instantaneous readout of customer consumption via remote instrumentation or computer Batch or continuous process Water softening regeneration Demineralization Reverse osmosis Chemical treatment/injection Filtration Boiler feed water make-up Cooling tower water make-up Irrigation High or low rate alarming Reverse flow alarming Dual optical switches allow the TRICON/E3 to distinguish between forward and reverse rotation, eliminating false pulse generation under low or no flow conditions. ARB ® UTILITY MANAGEMENT SYSTEMS TRICON/E ® 3 transmitters provide an interface between the water meter and an electronic controller for batching processes, monitoring flow totalization, and/or flow rate data. Neptune provides a limited warranty with respect to its TRICON/E3 transmitters for performance, materials, and workmanship. | [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903

Upload: trinhminh

Post on 25-Mar-2018

240 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: TRICON/E 3 TRANSMITTER - Meter, Valve And Controlmetervalveandcontrol.com/pdf/.../02f-TRICON-E3-Transmitter...Sheet.pdf · PRODUCT SHEET TRICON/E®3 TRANSMITTER KEY FEATURES Electronic

P R O D U C T S H E E T

TRICON/E®3 TRANSMITTER

KEY

FEA

TUR

ES

n Electronic pulse output proportional tothe meter’s rate of flow

n Electronic pulse output available with4–20mA analog output or highfrequency forward/reverse pulse output

n Mounts between the meter andregister – Direct Read, ARB®,ProRead™, E-Coder®, or E-Coder)R900i ™

n Utilizes dual optical switch type design which is more accurate andreliable than the older single opticalswitch designs

n Stainless steel ball bearings minimize torque

n Tamperproof seal pin to preventunauthorized access

n In-line adaptability allows installationor service without interrupting themeter service

WA

RR

AN

TY

An electronic digital pulse output with the4–20mA analog option is available forcustomers requiring both digital and analogoutputs. Reverse flow indication isavailable with the high frequencyforward/reverse pulse output option.

The TRICON/E3 transmitter mountsbetween the meter maincase and theregister. The bayonet-type mount allowsthe TRICON/E3 to be easily retrofitted tomany existing Neptune meters withoutinterruption. Contact Neptune regarding compatibility.

The TRICON/E3 with the 4–20mA analogoption provides an analog signal that isproportional to the flow. Together, thedigital pulse signal and the 4–20mA analogoutput provide information on totalconsumption and flow rate for closemonitoring of water usage.

The TRICON/E3 with the high frequencyforward/reverse pulse output option can beused in applications where directional flowmonitoring is required in addition to totalconsumption and flow information.

Every Neptune meter meets or exceeds thelatest AWWA standards ensuring accurate,dependable performance.

Neptune TRICON/E3 units are ideally suitedfor monitoring/controlling total flow rate datasuch as:

n Instantaneous readout of customerconsumption via remote instrumentationor computer

n Batch or continuous processn Water softening regenerationn Demineralizationn Reverse osmosisn Chemical treatment/injectionn Filtrationn Boiler feed water make-upn Cooling tower water make-up n Irrigationn High or low rate alarmingn Reverse flow alarming

Dual optical switches allow the TRICON/E3 todistinguish between forward and reverserotation, eliminating false pulse generationunder low or no flow conditions.

ARB® UTILITY MANAGEMENT SYSTEMS™

TRICON/E®3 transmitters provide an interface between the watermeter and an electronic controller for batching processes,

monitoring flow totalization, and/or flow rate data.

Neptune provides a limited warranty withrespect to its TRICON/E3 transmitters forperformance, materials, and workmanship.

| [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903

Page 2: TRICON/E 3 TRANSMITTER - Meter, Valve And Controlmetervalveandcontrol.com/pdf/.../02f-TRICON-E3-Transmitter...Sheet.pdf · PRODUCT SHEET TRICON/E®3 TRANSMITTER KEY FEATURES Electronic

PS TRICONE 02.10 © Copyright 2010, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc. TouchRead is a registered trademark of Sensus Metering System.

neptunetg.com

Neptune Technology Group Inc.1600 Alabama Highway 229Tallassee, AL 36078USATel: (800) 645-1892Fax: (334) 283-7293

Neptune Technology Group (Canada) Ltd.7275 West Credit AvenueMississauga, Ontario L5N 5M9CanadaTel: (905) 858-4211Fax: (905) 858-0428

Neptune Technology Group Inc.Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708Fax: (525) 55203 6503

n Sizes:

• T-10 (5/8”–2”)

• HP Turbine (1 1⁄2”–20”)

• TRU/FLO Compound (2”–6”x8”)

• HP Fire Service Turbine (3”–10”)

• HP PROTECTUS III (4”–10”)n Register Compatibility:

• Direct Read

• ARB V

• ProRead (ARB VI)

• E-Coder

• E-Coder)R900in Connection Wire:

• Distances up to 1000 feet – AWG

• #22 twisted pair cable

SP

ECIF

ICA

TIO

NSPERFORMANCE DATA

ELECTRICAL CHARACTERISTICS(OVER 0-70°C OPERATING TEMPERATURE)

Meter Type Pulses/ Flow Rate @ Flow Rate Value @& Size US Gallons 4 mA Output (US GPM) 20 mA Output (US GPM)

T-105/8” 578.1 0 203/4” 322.6 0 301” 150.8 0 50

1 1/2” 67.57 0 1002” 37.3 0 160

TRU/FLO® Compound (Turbine Side) and HP TRU/FLO (Turbine Side)2” HP 6.095 0 200

3” 2.890 0 4504” 1.590 0 1,0006” 0.464 0 2,000

HP Turbine1 1/2” 6.095 0 160

2” 6.095 0 2003” 11.20 0 4504” 7.556 0 1,2006” 0.7273 0 3,0008” 0.7556 0 4,00010” 0.7556 0 6,50012” 0.7556 0 8,00016” 0.07556 0 13,50020” 0.07556 0 22,000

HP PROTECTUS III®

4” 7.556 0 1,2006” 0.7556 0 2,8888” 0.6095 0 4,95910” 0.5333 0 9,209

Parameter Description Min Max UnitsHF and UP/DN Digital Pulse Model

VCC Supply Voltage (DC) 11.5 26.5 VoltsIs Supply Current 0.020 0.050 Amps

Vol Low Output Voltage 0 0.4 VoltsVoh High Output Voltage 8.5 12 VoltsIol Current at Vol .010 AmpsIoh Current at Voh .010 Amps

tr I-h Output Rise Time 2* µsectf h-l Output Fall Time 2* µsec

Measured with RL = 2.4 Kohms, CL = 50 pF4-20 ma Model

VCC Supply Voltage (DC) 22.5 26.5 VoltsIs Supply Current 0.1 AmpsRL Loop Resistance 0 600 Ohms

Gain Scaling Accuracy 0.5 %FSZero Offset Accruacy 0.2 %FS

Note: initial calibration is 1% totalBoth Models (unless otherwise specified)

Operating Temperature 0 70 Degrees CStorage Temperature -40 85 Degrees C

Supply Voltage -30 30 VoltsOutput Load (Pulse Output) 1200 Ohms

Output Current (Pulse Output) 0.01 Amps

Nep

tune

enga

ges

inon

goin

gre

sear

chan

dde

velo

pmen

tto

impr

ove

and

enha

nce

itspr

oduc

ts.

Ther

efor

e,N

eptu

nere

serv

esth

erig

htto

chan

gepr

oduc

tors

yste

msp

ecifi

catio

nsw

ithou

tnot

ice.

| [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903