triggerfish glaucoma monitoring system bme 181 brittany m. alphonse biomedical engineering
TRANSCRIPT
![Page 1: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/1.jpg)
TRIGGERFISHGlaucoma Monitoring System
BME 181 Brittany M. Alphonse Biomedical Engineering
![Page 2: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/2.jpg)
Table of Contents
Glaucoma Current Glaucoma
Monitoring Systems
Triggerfish Glaucoma Monitoring System
Triggerfish System Components
Benefits
![Page 3: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/3.jpg)
Glaucoma
Progressive and Irreversible Disease leads to blindness
Deterioration of Optic Nerve fluid accumulates in eye high levels of liquid inside eye Diameter of cornea changes
Asymptomatic Contributor of disease:
frequent changes in pressure over the span of a day
high peaks in levels during night 4% of population is affected
40+ years of age
![Page 4: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/4.jpg)
Current Glaucoma Monitoring Systems Measures static intraocular pressure Single Snapshots in Time
taken during the day when pressure is lowest
Monitoring in Overnight Sleep Labs cumbersome expensive
Frequent Punctual Measurements affects intraocular pressure checks pressure peaks
![Page 5: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/5.jpg)
Triggerfish System
Created by SENSIMED First of its Kind on the
market constant reading
device Safety Approval in
Europe last year Expected U.S. Food
and Drug Administration Approval in late 2011
Non-Invasive Continuous Monitoring System
Measures Intraocular Pressure up to 24 hours
Does Not Interfere with Normal Vision
Constant Reading for Fraction of Price
![Page 6: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/6.jpg)
Triggerfish System Components
Disposable Contact Lens soft hydrophilic silicone sensor and
microprocessor on outer edge
MEMS Sensor strain gauge monitors
diameter change in cornea
Telemetry Microprocessor Processes level changes transmits to receiver
Sensor and Processor
![Page 7: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/7.jpg)
Components Continued
Circular Antenna taped around the eye
Sends Energy to Sensor
Receives Measurement Information
Connected to Portable Recorder thin flexible data cable
Antenna
![Page 8: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/8.jpg)
Components Continued
Battery Powered Stores Measured
Information Wirelessly Uploads
Information Worn Around Neck
Ophthalmologist Receives Information
Visualize Intraocular Pressure Profile
Recorder/ Receiver Software
![Page 9: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/9.jpg)
Benefits of Triggerfish System Improved Understanding of Pressure
Change pressure during day versus night
More Efficient Personalized Drug Delivery and Treatment Adapt Treatment
dependent on changing conditions Sensor is Placed Outside of Vision Field Early Diagnosis and Treatment
![Page 10: TRIGGERFISH Glaucoma Monitoring System BME 181 Brittany M. Alphonse Biomedical Engineering](https://reader036.vdocuments.net/reader036/viewer/2022071807/56649e875503460f94b8acd4/html5/thumbnails/10.jpg)
References for Pictures
http://www.sensimed.ch/S-Trig-benefits.htm
http://www.technologyreview.com/business/24931/page1/
http://www.sensimed.ch/S-Trig-solution.htm