    Fireproof ROOF Panels Trimoterm SNVTechnical Information

  • 8/10/2019 trimo 2

    2/4

    Fireproof ROOF Panels Trimoterm SNV

    Technical Data

    The outstanding technical properties of Trimoterm SNV fireproof roof panels are the

    result of careful material selection and modern production processes.

    * Required control of distances between supports relating to the static system and loading.

    Loading by snow (kN/m2)

    Distance(m)

    Structural Design Data

    Trimo standards consider the most typical case studies of snow loading in accordance with

    general sales licence Z-10.4-240 when calculating maximum structural span.

    Technical data SNV SNV 60 SNV 80 SNV 100 SNV 120 SNV 150 SNV 200

    Panel thickness [mm] 60 80 100 120 150 200

    Weight SNV [kg/m2] Fe 0.6 / Fe 0.6 18.9 21.3 23.7 26.1 29.7 35.7

    U Thermal conductivity [W/m2K](acc to DIN 52611 and DIN 4108)

    0.61 0.48 0.40 0.34 0.27 0.21

    Fire resistance class REI(acc to EN 1365-2)*

    REI 60 REI 120 REI 150

    Combustibility of insulant core(acc to EN 13501-1)

    Non - combustible, class A1

    Rw Sound reduction [dB]Fe 0.6 / Fe 0.6 30

    Min. roof slope 5 or 3 with additional sealing

    Cover width [mm] 1000

    Panel lenght [m] from 2 to 14

    Load-bearing capacity curves have been calculated using the software Sand Stat 3 for multi-span structure of standard panel SNVs,closed building and normal internal temperature. Fixing and required width of supports should be determined for each individual

    project by Trimo Technical Support.

  • 8/10/2019 trimo 2

    3/4

    Loading by snow (kN/m2)

    Distance(m)

    Sound Insulation

    Sound insulation has been measured on a Trimoterm SNV 100 roof panel - Report No. P 1489/

    97-510-1, ZAG Ljubljana.

    Certificates

    Frequency f (Hz)

    SoundinsulationR`(dB)

    Standardcurve

    Cert. No. 650a to LPS 1208

  • 8/10/2019 trimo 2

    4/4

    Coatings

    Steel sheet is preliminary hot galvanised and colour pre-coated. Thickness of a zinc layer is

    275 g (Zn)/m2(DIN EN 10142, DIN EN 10147) while colour coating is performed by Coil Coating

    procedure. This denotes painting between cylinders and drying in a furnace at a temperature

    of minimum 200C.

    Basic properties SP PVDF

    Class of anticorrosive protection according to DIN 55928/1 III III

    Marking of anticorrosive system according to DIN 55928/8 3-160.2 3-600.1

    Temperature resistance (C) up to +80 up to +110

    Thickness of a a layer (my) 25 25

    External climate

    Normal

    Urban and industrial

    Harsh industrial -

    Maritime climate1 to 10 km from the coast -

    < 1 km from the coast -

    Conditions of

    buildings interiors

    t 25C , 80 %

    t 25C , > 80 %

    t 50C , > 80 % -

    Without heating

    Suitable without

    reservations

    Very suitable

    Suitable

    - Unsuitable

    Two types of metal sheet coatings are used:

    - Protection based on polyester marked as SP - standard protection.

    - Protection based on polyvinyl idenfluoride marked as PVDF - available on request.

    All rights to alternations reserved. The last version of the document can be found on www.trimo.si. Publishedby:TRIMOd.d.,

    Design:MetaGabrijel,

    Photography:JanezErjavec,Printedby:TiskarnaPetri,Circulation:6000/ANG,12/2004