trimo 2
TRANSCRIPT
-
8/10/2019 trimo 2
1/4
Fireproof ROOF Panels Trimoterm SNVTechnical Information
-
8/10/2019 trimo 2
2/4
Fireproof ROOF Panels Trimoterm SNV
Technical Data
The outstanding technical properties of Trimoterm SNV fireproof roof panels are the
result of careful material selection and modern production processes.
* Required control of distances between supports relating to the static system and loading.
Loading by snow (kN/m2)
Distance(m)
Structural Design Data
Trimo standards consider the most typical case studies of snow loading in accordance with
general sales licence Z-10.4-240 when calculating maximum structural span.
Technical data SNV SNV 60 SNV 80 SNV 100 SNV 120 SNV 150 SNV 200
Panel thickness [mm] 60 80 100 120 150 200
Weight SNV [kg/m2] Fe 0.6 / Fe 0.6 18.9 21.3 23.7 26.1 29.7 35.7
U Thermal conductivity [W/m2K](acc to DIN 52611 and DIN 4108)
0.61 0.48 0.40 0.34 0.27 0.21
Fire resistance class REI(acc to EN 1365-2)*
REI 60 REI 120 REI 150
Combustibility of insulant core(acc to EN 13501-1)
Non - combustible, class A1
Rw Sound reduction [dB]Fe 0.6 / Fe 0.6 30
Min. roof slope 5 or 3 with additional sealing
Cover width [mm] 1000
Panel lenght [m] from 2 to 14
Load-bearing capacity curves have been calculated using the software Sand Stat 3 for multi-span structure of standard panel SNVs,closed building and normal internal temperature. Fixing and required width of supports should be determined for each individual
project by Trimo Technical Support.
-
8/10/2019 trimo 2
3/4
Loading by snow (kN/m2)
Distance(m)
Sound Insulation
Sound insulation has been measured on a Trimoterm SNV 100 roof panel - Report No. P 1489/
97-510-1, ZAG Ljubljana.
Certificates
Frequency f (Hz)
SoundinsulationR`(dB)
Standardcurve
Cert. No. 650a to LPS 1208
-
8/10/2019 trimo 2
4/4
Coatings
Steel sheet is preliminary hot galvanised and colour pre-coated. Thickness of a zinc layer is
275 g (Zn)/m2(DIN EN 10142, DIN EN 10147) while colour coating is performed by Coil Coating
procedure. This denotes painting between cylinders and drying in a furnace at a temperature
of minimum 200C.
Basic properties SP PVDF
Class of anticorrosive protection according to DIN 55928/1 III III
Marking of anticorrosive system according to DIN 55928/8 3-160.2 3-600.1
Temperature resistance (C) up to +80 up to +110
Thickness of a a layer (my) 25 25
External climate
Normal
Urban and industrial
Harsh industrial -
Maritime climate1 to 10 km from the coast -
< 1 km from the coast -
Conditions of
buildings interiors
t 25C , 80 %
t 25C , > 80 %
t 50C , > 80 % -
Without heating
Suitable without
reservations
Very suitable
Suitable
- Unsuitable
Two types of metal sheet coatings are used:
- Protection based on polyester marked as SP - standard protection.
- Protection based on polyvinyl idenfluoride marked as PVDF - available on request.
All rights to alternations reserved. The last version of the document can be found on www.trimo.si. Publishedby:TRIMOd.d.,
Design:MetaGabrijel,
Photography:JanezErjavec,Printedby:TiskarnaPetri,Circulation:6000/ANG,12/2004