typical vertical joint - architects' surfaces f2.10... · fundermax exterior cladding panel...

11
01 TYPICAL VERTICAL JOINT ventilation chamber FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) panel fastener (SFS) vertical hat profile RU 1 4 " wall anchor per installer (by others) interior board (by others) exterior sheathing (by others) SCALE: 1:1

Upload: others

Post on 03-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

01

TYPICAL VERTICAL JOINT

ventilation chamber

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

panel fastener (SFS)

vertical hat profile

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

interior board (by others)

exterior sheathing (by others)

SCALE: 1:1

Page 2: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

02

90° INSIDE CORNER

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

self drilling screw Ø

5,5x25mm & Ø16mm

wall bracket F2.080D6,5

panel fastener (SFS)

vertical Z-profile

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

self drilling screw Ø

5,5x25mm & Ø16mm

insulation (by others)

weather barrier (by others)

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

SCALE: 1:1

Page 3: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

03

90° OUTSIDE CORNER

ventilation chamber

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

SCALE: 1:1

exterior sheathing (by others)

vertical Z-profile

horizontal L-profile 60x40x2.5mm

/ 2.36" x 1.57" x0.1"

wall bracket F2.080D6,5

panel fastener (SFS)

Page 4: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

04

VERTICAL JOINT @ SUB-STRUCTURE JOINT

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

horizontal L-profile 60x40x2.5mm

/ 2.36" x 1.57" x0.1"

vertical Z-profile

self drilling screw Ø

5,5x25mm & Ø16mm

panel fastener (SFS)

horizontal L-profile 60x40x2.5mm /

2.36" x 1.57" x0.1"

exterior insulation (by others)

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

steel stud (by others)

insulation (by others)

weather barrier (by others)

interior board (by others)

exterior sheathing (by

others)

SCALE: 1:1

wall bracket F2.080D6,5

Page 5: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

ventilation chamber

05

TYPICAL INTERMEDIATE SUPPORT

self drilling screw Ø

5,5x25mm & Ø16mm

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

horizontal L-profile 60x40x2.5mm /

2.36" x 1.57" x0.1"

panel fastener (SFS)

self drilling screw Ø

5,5x25mm & Ø16mm

wall bracket F2.080D6,5

exterior insulation (by others)

steel stud (by others)

insulation (by others)

weather barrier (by others)

SCALE: 1:1

Page 6: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

06

PANEL @ BASE

Pos.4

Vent. profile 100x30 - 9333

Pos.3

L-profile 40x60x1,6

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

insulation (by others)

vertical Z-profile

panel fastener (SFS)

wall bracket F2.080D6,5

horizontal L-profile 60x40x2.5mm /

2.36" x 1.57" x0.1"

self drilling screw Ø

5,5x25mm & Ø16mm

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

wall bracket F2.080D6,5

weather barrier (by others)

5/8" sheathing

steel stud wall

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

fastener (rivet)

insulation (by others)

SCALE: 1:1

Page 7: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

07

PANEL @ WINDOW HEAD

window by others

flashing by others

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

insulation (by others)

vertical Z-profile

panel fastener (SFS)

self drilling screw Ø

5,5x25mm & Ø16mm

horizontal L-profile 60x40x2.5mm

/ 2.36" x 1.57" x0.1"

weather barrier (by others)

wall bracket F2.080D6,5

horizontal L-profile 60x40x2.5mm / 2.36" x

1.57" x0.1"

self drilling screw Ø

5,5x25mm & Ø16mm

5/8" sheathing

steel stud wall

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

insulation (by others)

SCALE: 1:1

Page 8: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

08

PANEL @ PARAPET

parapet coping (by others)

horizontal L-profile 60x40x2.5mm

/ 2.36" x 1.57" x0.1"

self drilling screw Ø

5,5x25mm & Ø16mm

panel fastener (SFS)

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

insulation (by others)

wall bracket F2.080D6,5

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

5/8" sheathing

steel stud wall

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

insulation (by others)

SCALE: 1:1

Page 9: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

09

PANEL @ WINDOW SILL

window sill flashing by others

window by others

panel fastener (SFS)

vertical Z-profile

self drilling screw Ø

5,5x25mm & Ø16mm

wall bracket F2.080D6,5

FUNDERMAX exterior cladding

panel 3/8" thick (by Architects Surfaces)

horizontal L-profile 60x40x2.5mm

/ 2.36" x 1.57" x0.1"

insulation (by others)

wall bracket F2.080D6,5

Ø0.21" or Ø

1

4

" wall anchor

per installer (by others)

weather barrier (by others)

self drilling screw

Ø 4,8x19mm (Ø0.19"x3/4")-st/st

5/8" sheathing (by others)

SCALE: 1:1

Page 10: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

horizontal section

horizontal section

horizontal section

scale: 1:2

horizontal section

horizontal section

SYSTEM F2.10 W/ 6" INSULATION

SYSTEM F2.10 W/ 5" INSULATION

SYSTEM F2.10 W/ 4" INSULATION

SYSTEM F2.10 W/ 3" INSULATION

SYSTEM F2.10 W/ 2" INSULATION

scale: 1:2

scale: 1:2

scale: 1:2

scale: 1:2

Page 11: TYPICAL VERTICAL JOINT - architects' surfaces F2.10... · FUNDERMAX exterior cladding panel 3/8" thick (by Architects Surfaces) FUNDERMAX exterior cladding panel 3/8" thick (by Architects

vertical section

SYSTEM F2.10 W/ 2" INSULATION

vertical section

SYSTEM F2.10 W/ 3" INSULATION

vertical section

SYSTEM F2.10 W/ 6" INSULATION

vertical section

scale: 1:2

SYSTEM F2.10 W/ 4" INSULATION

vertical section

SYSTEM F2.10 W/ 5" INSULATION

scale: 1:2

scale: 1:2

scale: 1:2